生物滤池工艺的数值模拟与运行优化   总被引:1,自引:1,他引:0  
邹宗森  施汉昌  陈向强  谢小青 《环境科学》2014,35(12):4627-4635
以筼筜污水处理厂生物滤池工艺(DNBF+BAF)为研究对象,应用Bio Win软件,构建该工艺的Bio Win模型,基于2013年9月和10月的实际运行数据,结合两种灵敏度分析方法,对Bio Win模型进行校正.结果表明,校正模型可对DNBF+BAF工艺进行有效模拟,且对该工艺的Bio Win模拟结果影响最为显著的3类参数为:与生物膜有关的参数、与异养菌(OHOs)有关的参数和曝气参数.然后应用校正模型模拟该工艺在不同工况条件下的运行结果,对其进行工艺优化.结果表明:1一级B排放标准的最佳运行条件为:回流比=50%,取消甲醇投加,此时进水C/N=4.43;2一级A排放标准的最佳运行条件为:回流比=50%,投加甲醇后的进水COD=155 mg·L-1,此时进水C/N=5.10.  相似文献   

2.
以污水厂实际二级出水为处理目标,通过中试试验研究了陶粒滤料反硝化生物滤池、固定床反硝化砂滤池和连续过滤连续反冲砂滤池的特性。以甲醇作为外加碳源,3种滤池均可实现出水平均总氮小于5 mg/L。不足量投加外碳源会出现出水亚硝态氮的积累。当进水TN为15 mg/L左右时,为达到出水TN小于5 mg/L,生物滤池、固定床砂滤池和连续过滤砂滤池建议滤速分别为不大于8,5.2,6.2 m/h;滤池反硝化碳源投加比例分别为4.28,3.0,3.2 g甲醇/gTN;对应的反硝化容积负荷平均值分别为1.1,0.8,1.2 kg/(m3·d)。进水组分分析发现,有机氮不是出水总氮小于5 mg/L的限制因素。  相似文献   

3.
研究在低水温条件下连续砂滤池的反硝化脱氮效果及其主要影响因素,寻找最佳的甲醇碳源投加比。运行结果表明:当水温降低至11.7℃时,在连续砂滤池里反硝化菌培养时间为24 d;反硝化脱氮稳定运行后,砂滤池的滤速为4 m/h时反硝化去除总氮量超过15 mg/L,容积负荷达0.6 kg/(m3·d),最佳甲醇碳源投加比为2.8~3.2,出水COD、SS浓度均可达到一级A排放标准;影响连续砂滤池反硝化脱氮效果的主要因素为进水水温、硝酸盐浓度、溶解氧浓度、上升水力流速和甲醇投加比。  相似文献   

4.
采用生物滤池探究部分反硝化(NO3--N还原到NO2--N)工艺应用于城市污水厂深度脱氮的可行性.以实际二级出水为进水,考察滤速、碳氮比(C/N)等影响因素对滤池快速启动及稳定运行的影响,分析了滤池沿程水质变化和系统微生物群落结构.结果表明,控制高滤速和低C/N,3d可实现部分反硝化滤池的快速启动,滤池120d平均亚硝态氮累积率(NTR)为60.3%,最高可达82.1%,成功构建了连续流生物膜部分反硝化工艺.高滤速条件有助提高滤池的NO2--N积累率,C/N对NO2--N积累率的影响较小,C/N为2~4,部分反硝化滤池的NTR维持在62.0%.沿程数据表明底部40cm的滤料层是部分反硝化滤池NO3--N去除和NO2--N累积的主要反应区域.由于采用实际水厂二级出水进行研究,扫描电镜和高通量测序结果表明存在多种具有反硝化功能的微生物,系统的微生物多样性较高.  相似文献   

5.
介绍了在全地埋式污水处理厂中具体采用了AAO+深床滤池工艺,采用BioWin软件,基于仿真模拟技术进行工艺比选设计,模拟结果表明,在设计参数相同的条件下,改进多级AO工艺的处理效果明显优于传统AAO工艺,因此,AAO主体工艺确定采用改进多级AO工艺,BAF方案主体工艺采用硝化反硝化生物滤池+反硝化生物滤池的形式;并对各分区水力停留时间、进水分配比例、内回流比和外回流比等参数进行优化,在保证出水水质的前提下,获得了最佳的工艺参数.  相似文献   

6.
针对二级污水处理厂深度处理的需要,对进水水质达到一级B或者劣于一级B,但优于二级标准的污水进行脱氮影响因素分析。研究表明,滤速在一定范围内对于硝化效果有积极影响,但不宜超过10 m/h,在低进水有机物浓度下,滤速在512 m/h时不是反硝化效果的限制因素。要取得良好的硝化效率和出水水质,硝化池的溶解氧应控制在3.5 mg/L左右,进水氨氮负荷应控制在0.48 kg/(m3·d)以下。  相似文献   

7.
一体式膜生物反应器同步硝化反硝化中试实验研究   总被引:1,自引:1,他引:0  
通过一体式膜生物反应器中试装置的连续运行,研究了DO、进水碳氮比(C/N)、有机负荷率(F/M)、pH值对同步硝化反硝化的影响机制,结果表明:一体式膜生物反应器中试装置中同步硝化反硝化效果最好的工作条件为:DO控制在0.8mg/L左右,进水C/N比在10左右,F/M为0.34kgCOD/(kgMLSS·d),pH值在中性略微偏碱处。  相似文献   

8.
以苯、联苯和萘为模型化合物,研究了厌氧滤池(AF)反应器在反硝化及连续运行条件下对含这几种芳香族化合物模拟废水的处理效果,并以葡萄糖为补充碳源,考察了不同C/N对有机物反硝化降解特性的影响.结果表明,在长期连续流运行及反硝化条件下,AF反应器对废水中几种典型芳香族化合物具有良好地去除效果,当进水COD浓度约为1?000mg/L,苯、联苯和萘总浓度为60mg/L时,出水COD去除率可达到90%,芳香族化合物的去除率可达到84%.苯比萘和联苯更易于反硝化降解.C/N在5~30范围内,苯的降解率均达到90%,C/N对苯的降解没有明显影响;COD、萘和联苯去除率受C/N影响较大,C/N为15时,COD、萘和联苯去除率最大,分别为90%、78%和82%.  相似文献   

9.
生物活性炭处理循环水产养殖废水及其影响因子研究   总被引:3,自引:0,他引:3  
黄晓婷  张再利  刘伟  陈兵  谢杰 《环境科学学报》2011,31(11):2380-2386
通过现场中试研究了生物活性炭(BAC)处理循环水产养殖废水中氨氮、亚硝态氮、硝态氮和COD的效果,考察了运行条件对硝化反硝化的影响.中试运行条件:滤速4m·h-1,水温22℃,pH7.21~7.65.在BAC进水溶解氧10.4~15.1mg·L-1、氨氮2.34~4.01mg·L-1、亚硝酸盐氮0.83~1.67mg·...  相似文献   

10.
速分球生物滤柱是速分技术与曝气生物滤池技术的结合。具有污泥消化和无需反冲洗等优点。实验采用速分球生物滤柱实验装置,以低C/N比生活污水为处理对象,考查了单污泥前置反硝化A2/O系统的脱氮除磷特性。实验结果表明,在平均C/N比为1.6,内回流比R为100%的条件下,平均进水COD、氨氮、TP分别为440.7、274.0和13.6 mg/L,平均去除率分别为77.0%、19.2%和42.4%。系统对氨氮的去除率较低,对总磷的去除率要明显高于对氨氮的去除率。结论得出,系统脱氮除磷的效果不理想。  相似文献   

11.
Tertiary denitrification is an effective method for nitrogen removal from wastewater. A pilot-scale biofilter packed with suspended carriers was operated for tertiary denitrification with ethanol as the organic carbon source. Long-term performance, biokinetics of denitrification and biofilm growth were evaluated under filtration velocities of 6, 10 and 14 m/hr. The pilot-scale biofilter removed nitrate from the secondary effluent effectively, and the nitrate nitrogen(NO_3-N) removal percentage was 82%, 78% and 55% at the filtration velocities of 6, 10 and 14 m/hr, respectively. At the filtration velocities of 6 and 10 m/hr, the nitrate removal loading rate increased with increasing influent nitrate loading rates, while at the filtration velocity of 14 m/hr, the removal loading rate and the influent loading rate were uncorrelated.During denitrification, the ratio of consumed chemical oxygen demand to removed NO_3-N was 3.99–4.52 mg/mg. Under the filtration velocities of 6, 10 and 14 m/hr, the maximum denitrification rate was 3.12, 4.86 and 4.42 g N/(m~2·day), the half-saturation constant was 2.61, 1.05 and 1.17 mg/L, and the half-order coefficient was 0.22, 0.32 and 0.24(mg/L)1/2/min,respectively. The biofilm biomass increased with increasing filtration velocity and was 2845,5124 and 7324 mg VSS/m~2 at filtration velocities of 6, 10 and 14 m/hr, respectively. The highest biofilm density was 44 mg/cm~3 at the filtration velocity of 14 m/hr. Due to the low influent loading rate, biofilm biomass and thickness were lowest at the filtration velocity of 6 m/hr.  相似文献   

12.
Tertiary denitrification is an effective method for nitrogen removal from wastewater. A pilot-scale biofilter packed with suspended carriers was operated for tertiary denitrification with ethanol as the organic carbon source. Long-term performance, biokinetics of denitrification and biofilm growth were evaluated under filtration velocities of 6, 10 and 14 m/hr. The pilot-scale biofilter removed nitrate from the secondary effluent effectively, and the nitrate nitrogen (NO3-N) removal percentage was 82%, 78% and 55% at the filtration velocities of 6, 10 and 14 m/hr, respectively. At the filtration velocities of 6 and 10 m/hr, the nitrate removal loading rate increased with increasing influent nitrate loading rates, while at the filtration velocity of 14 m/hr, the removal loading rate and the influent loading rate were uncorrelated. During denitrification, the ratio of consumed chemical oxygen demand to removed NO3-N was 3.99–4.52 mg/mg. Under the filtration velocities of 6, 10 and 14 m/hr, the maximum denitrification rate was 3.12, 4.86 and 4.42 g N/(m2·day), the half-saturation constant was 2.61, 1.05 and 1.17 mg/L, and the half-order coefficient was 0.22, 0.32 and 0.24 (mg/L)1/2/min, respectively. The biofilm biomass increased with increasing filtration velocity and was 2845, 5124 and 7324 mg VSS/m2 at filtration velocities of 6, 10 and 14 m/hr, respectively. The highest biofilm density was 44 mg/cm3 at the filtration velocity of 14 m/hr. Due to the low influent loading rate, biofilm biomass and thickness were lowest at the filtration velocity of 6 m/hr.  相似文献   

13.
涤纶高弹丝纤维球滤料过滤特性研究   总被引:2,自引:0,他引:2  
采用自主研制的涤纶高弹丝纤维球滤料对景观水进行过滤试验,研究其过滤特性及相关因素对过滤性能的影响. 结果表明,在不投加任何絮凝剂,滤速为30 m/h,平均进水浊度为87.5 NTU时,纤维球滤料过滤周期达16.5 h左右,出水浊度维持在3~5 NTU.当PAFC投加量为12 mg/L,滤速为30~50 m/h,进水浊度为50~70 NTU时,过滤出水浊度可以维持在1 NTU以下,过滤周期达6 h以上,周期截污量为30~45 kg/m3. 采用气冲-气水联合反冲-水冲的反冲洗方式,当气冲强度为25 L/(s·m2),水冲强度为8 L/(s·m2)时,纤维球滤料积泥量约占滤料质量的4.53%.   相似文献   

14.
基于浓差极化现象和膜孔堵塞效应,建立了污水深度处理中超滤工艺对有机物的截留模型.利用中试试验数据率定模型参数并验证模型的模拟效果.模型验证结果表明,该模型能够较好地模拟超滤工艺出水UV254值随时间的变化特征,基于最优参数得到的模拟值与相应实测值相对误差的绝对值均低于10%.并且模型参数区域灵敏度分析和不确定性分析结果表明,该模型的结构具有较高的可靠性.应用该模型研究了过滤时间、通量和进水浓度变化对出水水质的影响.结果表明,在过滤初期膜孔堵塞效应占主导地位并增加超滤膜对有机物的截留效果,在过滤后期浓差极化现象占主导地位并降低超滤膜对有机物的截留效果;当进水UV254浓度恒为0.1cm-1时,通量从5×10-5m/s增至1×10-4m/s,导致UV254截留率降低13%;当通量恒为5×10-5m/s时,进水UV254浓度从0.2cm-1降至0.1cm-1,使得出水浓度降低50%.因此,模型可应用于模拟进水水质和操作条件对污水深度处理中超滤工艺出水水质的影响,为从预处理、过滤周期和通量等方面改进和优化超滤工艺提供基础.  相似文献   

15.
曝气生物滤池处理城市污水的试验研究   总被引:3,自引:0,他引:3  
采用两级曝气生物滤池处理含工业废水的城市污水。结果表明:在水温26.7~29.5℃,气/水比6∶1,进水CODcr浓度为260~600mg/L,NH3 浓度为52~90mg/L、SS浓度为60~90mg/L、滤速为2.2m/h条件下,系统取得了良好的处理效果,其CODcr、NH3、SS的平均去除效率分别达到80.2%、97.8%、95.4%、出水CODcr、NH3、SS浓度满足污水综合排放要求。  相似文献   

16.
耦合反硝化的CANON生物滤池脱氮研究   总被引:1,自引:0,他引:1  
为探究有机物对全程自养脱氮(CANON)工艺的脱氮性能的影响,采用上向流火山岩填料反应器处理模拟废水,在反应器最优工况下实现亚硝化、厌氧氨氧化与反硝化的耦合.结果表明,滤柱在氨氮浓度为200mg/L时的最优总氮去除率均值可达76.73%,总氮去除负荷为2.82kgN/(m3·d).C/N为0.2的有机物水平对反应器的脱氮效果具有促进作用,并可通过HRT的调节实现总氮去除率大于89%(理想条件下CANON的最大脱氮率).因此,通过控制C/N可以提升滤柱氮素去除效率.  相似文献   

17.
以模拟低C/N比污水为研究对象,采用集成模块式污水处理装置与技术,在反应器主反应区实现了同步硝化反硝化(SND),研究了在不同DO、HRT、C/N比、pH值下污水氨氮、总氮的去除,研究结果表明,DO=1.2~1.4mg/L,总HRT=20h(主反应区HRT=8h),原水C/N=5:1,pH=7.5时,NH3--N可以从15mg/L降至2.5mg/L,总氮可以从20mg/L降至4mg/L,去除率可以达到83%和80%;主反应区SND动力学模型求解得出集成模块式污水处理SND动力学方程及反硝化过程中硝酸盐氮饱和常数 =1.55mg/L,远高于普通活性污泥反硝化过程中的饱和常数0.06~0.2mg/L.集成模块式污水处理技术能高效去除低C/N比污水中的总氮,且具有运行稳定和抗冲击等优点.为中小城镇生活污水深度脱氮提供了技术支持和理论基础.  相似文献   

18.
在太湖流域某小城镇污水处理厂研究中试气升式氧化沟的污水处理效果,获取了出水主要指标稳定达标的工艺参数.结果表明,出水COD<50mg/L的最大容积负荷为0.88kg/(m3·d).NH4+–N污泥负荷不大于0.06kg /(kg·d)时,出水能达到排放标准要求的5 mg/L.直沟段DO降低到0.6~1.0mg/L后,进出水TN平均浓度分别为30.7,11.3mg/L,并能保证出水TN<15 mg/L稳定运行14d以上.进气量30m3/h时,直段底部最大流速为0.19m/s,中上部流速为0.03m/s,此时沟底没有出现污泥沉降,出水各项指标稳定达标.生产型气升式氧化沟的占地面积将比传统氧化沟至少减少25%.  相似文献   

19.
EGSB处理玉米淀粉生产废水中试研究   总被引:11,自引:0,他引:11  
研究了厌氧膨胀颗粒 (EGSB)反应器处理玉米生产废水的运行过程现象 ,结果表明 ,液体表面上升流速是影响EGSB反应器效能的重要参数 ,当进水CODCr为 35 0 0~ 6 5 0 0mg L时 ,液体表面上升流速为 1~ 3 5m h时 ,EGSB反应器处理始终保持在 85 %以上 ,污泥经过选择后能够适应EGSB反应器的运行条件。  相似文献   