首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
In humans, the metabolism of environmental phenols may include the formation of conjugated species (e.g., glucuronides and sulfates), but the free species—not the conjugated forms—are considered biologically active. Therefore, information on the concentration of these free species in blood or urine could be helpful for risk assessment. Because conjugates could hydrolyze to their corresponding free forms during collection, handling, and storage of biological specimens, information on the temporal stability of the conjugates is of interest. Previously, we reported the temporal stability of urinary conjugates of several environmental phenols, but data on the stability of phenols' conjugated species in serum, albeit critical if concentrations of free and conjugated species are compared, are largely unknown. In the present study, we investigate the stability of the conjugates of four phenols—bisphenol A, benzophenone-3, triclosan, and 2,5-dichlorophenol—and two parabens—methyl paraben and propyl paraben—in 16 human serum samples for 30 days at above-freezing temperature storage conditions (4 °C, room temperature, and 37 °C). These conditions reflect the worst-case scenarios that could occur during the short-term storage of biological samples before their long-term storage at controlled subfreezing temperatures. We found that the percentage of the conjugated species of the four detected compounds (2,5-dichlorophenol, triclosan, and methyl and propyl parabens) in these serum specimens even when stored at 37 °C for at least 30 days did not vary significantly. These preliminary data suggest that the phenols' serum conjugates appear to be more stable than their corresponding urinary conjugates, some of which started to hydrolyze within 24 h under similar storage conditions. The reported stability of these conjugated species in human serum also suggests that the free species are unlikely to have resulted from the hydrolysis of their corresponding conjugates. This information could be important for interpreting the low concentrations of free phenol species detected in serum samples of nonoccupationally exposed populations. To our knowledge, this is the first study to report on the stability of conjugated species in serum, and as such requires replication.  相似文献   

2.
The air quality in a newly built preschool was investigated in a longitudinal study. Typical air contaminants emanating from building materials were determined, their variation over time (0–18 months) was measured, and the influence of the ventilation system (81%–91% recirculation of return air) on contaminant concentrations was studied. Volatile organic compounds were sampled by adsorption on porous polymer, analysed by a GC/FID system, and identified by MS. A spatial build-up in concentration (ppb or μg/m3 levels) is evident for all the organic compounds, as well as for CO2, from the outdoor air, through the ventilation system, and through the rooms to the exhaust air. The longitudinal comparison over time shows that all the organic compounds decline in concentration mainly within the first 6 months of occupancy: 1-butanol 4–14 times, toluene and pentanal + hexanal 2–4 times, while formaldehyde remained at a constant low level of 90 ppb (110 μg/m3). It is difficult to believe that the problems of poor air quality in 100 preschools in Stockholm are caused by the organic compounds alone unless interactions occur. A preschool building needs to be gassed off during the first 6 months after its construction with no recirculation of return air allowed (outdoor air rate approx 4–5 ach). During at least 1–2 additional years, it is desired that the recirculation rate of return air is restricted, perhaps to 50%.  相似文献   

3.
The use of building materials containing naturally occurring radionuclides as 40K, 232Th, and 238U and their progeny results in external exposures of the residents of such buildings. In the present study, indoor dose rates for a typical Jordan concrete room are calculated using Monte Carlo method. Uniform chemical composition of the walls, floor and ceiling as well as uniform mass concentrations of the radionuclides in walls, floor and ceiling are assumed.Using activity concentrations of natural radionuclides typical for the Jordan houses and assuming them to be in secular equilibrium with their progeny, the maximum annual effective doses are estimated to be 0.16, 0.12 and 0.22 mSv a−1 for 40K, 232Th- and 238U-series, respectively. In a total, the maximum annual effective indoor dose due to external γ-radiation is 0.50 mSv a−1. Additionally, organ dose coefficients are calculated for all organs considered in ICRP Publication 74. Breast, skin and eye lenses have the maximum equivalent dose rate values due to indoor exposures caused by the natural radionuclides, while equivalent dose rates for uterus, colon (LLI) and small intestine are found to be the smallest. More specifically, organ dose rates (nSv a−1 per Bq kg−1) vary from 0.044 to 0.060 for 40K, from 0.44 to 0.60 for radionuclides from 238U-series and from 0.60 to 0.81 for radionuclides from 232Th-series.The obtained organ and effective dose conversion coefficients can be conveniently used in practical dose assessment tasks for the rooms of similar geometry and varying activity concentrations and local-specific occupancy factors.  相似文献   

4.
Measurement of personal exposure to ambient level particulate concentrations is often extremely difficult because of a lack of personal exposure monitors capable of collecting measurable quantities within a meaningful sampling period. A new personal exposure monitor for two fractions of inhalable particulates (i.e., the 3–15 μm aerodynamic diameter and the < 3 μm or respirable fraction) has been developed and characterized. This monitor is capable of collecting a sample of each fraction that is quantifiable with ambient concentrations of inhalable/respirable particulates as low as 25 μg/m3 in a 24-h sampling period. Wind tunnel tests have been made on the particulate personal exposure monitor to determine sampling efficiency as a function of relative wind speed and orientation with respect to the sampler.  相似文献   

5.
The relationship between the odor strength of total air samples and the odor strengths of the constituents was investigated in three field experiments in an office building and a new preschool. The odor strength was scaled by magnitude estimation according to a master scale principle which results in comparable values for the total and the constituent odors. Between 60 and 120 chemical components were detected by GC/FID in the indoor air samples (N = 66). Most (81%) of the detected components in an air sample were odorous, even though most of them were of the low concentrations. By a method of pattern analysis, chemical as well as odor patterns of indoor air were found to be characteristics of different buildings. From the odor patterns (POG), the “odor print” of the outdoor air associated with the buildings was also recognized in the indoor air. Thus, the “odor print” of an air sample is different from its “chemical print”. A model was found that predicts the overall odor strength of an air sample from the number of FID-detected components most frequently reported to have a strong odor.  相似文献   

6.
A complete assessment of the health effects of diesel emissions must take into account the possible chemical transformations (and associated biological impacts) of particulate organic matter (POM) due to reactions with the many gaseous copollutants which have now been unambiguously demonstrated to be present in atmospheres burdened by photochemical air pollution. These copollutants include the “trace” species, nitric (HNO3) and nitrous (HONO) acids, the nitrate radical (NO3), formaldehyde (H2CO) and formic acid (HCOOH), as well as the criteria pollutants, ozone (O3) and nitrogen dioxide (NO2). Techniques for establishing the atmospheric concentrations of the trace pollutants (and their spatial and temporal variations) are briefly described, and we present results of investigations into the reactions of polycyclic aromatic hydrocarbons (PAH) coated on filters and exposed to ambient concentrations of O3 and NO2. Environmental health implications of these results are discussed and include the potential for sampling “artifacts” and their possible effects on the correlation (or lack thereof) between ambient PAH levels and urban lung cancer rates, as well as the problems associated with understanding the appropriate POM “dose” to be employed in animal testing and assessments of impacts on human health.  相似文献   

7.
A chronic exposure study was initiated to determine the effects of diesel exhaust on the health of experimental animals. For this purpose, test atmospheres of clean air (control) or freshly diluted diesel exhaust at concentrations of 250, 750, and 1500 μg/m3 were supplied to four 12.6 m3 inhalation chambers which housed rats and guinea pigs. Diesel aerosol size and concentration, as well as chamber temperature and relative humidity, were continually monitored and controlled to maintain the exposure dose levels and an environment of 22±2°C and 50%±20% relative humidity. The concentrations of CO and NOx were found to be 5.8±1.0 mg/m3 and 7.9±1.0 mg/m3 above ambient in the chamber containing 1500 μg/m3 of particulate. Animals were supplied from the chambers, on a random basis, for both intramural and extramural studies throughout the exposure period. The experiment ran uninterrupted for over twelve months with mean diesel particle mass concentrations within 2% of the target values.  相似文献   

8.
This paper presents an innovative, quantitative assessment of pollution avoidance attributable to environmental regulation enforced through integrated licensing, using Ireland's pharmaceutical-manufacturing sector as a case study. Emissions data reported by pharmaceutical installations were aggregated into a pollution trend using an Environmental Emissions Index (EEI) based on Lifecycle Assessment methodologies. Complete sectoral emissions data from 2001 to 2007 were extrapolated back to 1995, based on available data. Production volume data were used to derive a sectoral production index, and determine ‘no-improvement’ emission trends, whilst questionnaire responses from 20 industry representatives were used to quantify the contribution of integrated licensing to emission avoidance relative to these trends. Between 2001 and 2007, there was a 40% absolute reduction in direct pollution from 27 core installations, and 45% pollution avoidance relative to hypothetical ‘no-improvement’ pollution. It was estimated that environmental regulation avoided 20% of ‘no-improvement’ pollution, in addition to 25% avoidance under business-as-usual. For specific emissions, avoidance ranged from 14% and 30 kt a− 1 for CO2 to 88% and 598 t a− 1 for SOx. Between 1995 and 2007, there was a 59% absolute reduction in direct pollution, and 76% pollution avoidance. Pollution avoidance was dominated by reductions in emissions of VOCs, SOx and NOx to air, and emissions of heavy metals to water. Pollution avoidance of 35% was attributed to integrated licensing, ranging from between 8% and 2.9 t a− 1 for phosphorus emissions to water to 49% and 3143 t a− 1 for SOx emissions to air. Environmental regulation enforced through integrated licensing has been the major driver of substantial pollution avoidance achieved by Ireland's pharmaceutical sector — through emission limit values associated with Best Available Techniques, emissions monitoring and reporting requirements, and performance targets specified in environmental management plans. This compliant sector offers a positive, but not necessarily typical, case study of IPPC effectiveness.  相似文献   

9.
Concentrations of silver, cadmium, chromium, iron, manganese, nickel, lead, vanadium, and zinc were determined in dust fallout samples from eight inland locations in Kuwait. Results were used to calculate enrichment factors for metals relative to their abundance in the continental crust using Fe as the conservative element. Five metals (Cu, Cr, Mn, Ni, and V) showed enrichment factors that were approximately unity (1.3–4.7). Higher enrichment factors for the rest (24–421) suggested an anthropogenic contribution for Ag, Cd, Pb, and Zn. However, all metals in dust fallout (except Pb and Zn) showed a degree of enrichment relative to unpolluted marine sediments that was approximately unity, suggesting a substantial aeolian contribution to trace metals in marine surface sediments. Higher enrichments for Pb and Zn probably reflect a larger input from local pollution sources. This is particularly true for lead, the enrichment of which showed a stronger association with the distribution of urban population. Probable contributions of aeolian transport to a band of elevated lead concentrations in marine surface sediments are discussed.  相似文献   

10.
Measurements of indoor atmospheric environment were carried out in a day nursery and a kindergarten, in which natural air infiltration supplied the rooms with only 1–2 m3 fresh air per person and hour under the prescribed occupancy. The exposure situation from the field was duplicated under controlled conditions in a climate chamber. The results indicate unacceptably high concentrations of carbon dioxide, and emphasize the need for more elaborate building design in airtight buildings.  相似文献   

11.
We have investigated the filtering effects of three types of air control systems of enclosed structures on viable particles in the ambient air. Aspergillus fumigatus and other thermophilic organisms were used as monitors for viable particles. The indoor concentrations of viable particles were found to be affected by building design and the use of conventional mechanical air systems. Viable particles of approximately 4.0 μm and greater in aerodynamic diameter were filtered from the air while respirable size particles less than 4.0 μm were not filtered as well. There was evidence of growth of viable particles within the mechanical air systems. Conventional air control systems may not be adequate for the control of viable particle contamination of the indoor environment without modifications and proper maintenance.  相似文献   

12.
A comparative study of the effects of heavy grazing load and periodic low cutting of above-ground phytomass on three plant species—Carex pediformis, Iris humilis, and Artemisia frigida—was performed in central Tuva in 1985–1989. Similar changes in the size of anatomical structures and ecophysiological characteristics of steppe plants were observed under the impact of both factors. They included signs of accelerated aging combined with adaptive reactions aimed at the most rapid development of shoots after the cessation of stress.  相似文献   

13.
The concentrations of chromium, iron, copper, nickel, lead, vanadium, and zinc in fish were determined to assess the impact of petroleum-refining activities and the 1991 Gulf War. Twenty-eight species of fish from the Kuwait coast were collected 50 m apart. Sample solutions prepared were analyzed using the atomic absorption spectrophotometry technique. Results show that fish samples contain 6.2 to 6.8 μg/g Cr, 4.2 to 96.2 μg/g Cu, 18.8 to 126.4 μg/g Fe, 0.5 to 20.4 μg/g Ni, 0.2 to 14.6 μg/g Pb, 0.02 to 15.6 μg/g V, and 7.6 to 81.3 μg/g Zn. Copper, nickel, and zinc in Station I, covering the Kuwait City area, were often greatly in excess of those present in Station II, covering the Al-Ahmadi area, while chromium, iron, lead, and vanadium were greater in Station II. Significant correlations were observed between some trace metals in fishes, indicating their common association.  相似文献   

14.
A new automated version of the piezoelectric microbalance measures the mass concentration of airborne particles smaller than a preselected aerodynamic cutoff diameter. It is designed for near-real-time, unattended, round-the-clock measurements of nearly any aerosol environment inhabited by humans. The instrument uses an electrostatic precipitator to deposit particles with greater than 95% efficiency onto a piezoelectric quartz crystal sensor which is able to detect a deposit of 0.005 μg. The precipitator and sensor are nearly identical to those in the portable instrument reported previously. Measurements comparing within ± 15% with gravimetrically measured filter samples are documented for a wide variety of aerosols in the 50 μg/m3 to 5.5 mg/m3 range. The instrument measures particles from 10 μm down to 0.01 μm in diameter, including submicron combustion smokes and metallic fumes. The piezoelectric microbalance technique senses the mass concentration of the aerosol, rather than light scattering properties as is done by photometers and nephelometers. The piezobalance, with 1 L/min sample flow, is more sensitive than any other mass-sensing instrument, making it especially suited for low concentration indoor measurements, even below 50 μg/m3. An automatic piezobalance recently measured respirable aerosol mass concentrations in several offices. Each measurement was the average concentration during a 30-min period. The 24-h/day measurements continued for several days. Especially interesting is the diurnal pattern, both for offices with and without smokers. The effect of a single nearby smoker was clearly illustrated when the smoker was absent one day in the middle of a week. Normal daytime peak concentrations in that office reached 80–110 μg/m3 with a smoker present, but only 50–60 μg/m3 when the smoker was absent. Curious smokers who briefly stopped byt o see the instrument caused single half-hour averages to triple, to values as high as 294 μg/m3 in one office.  相似文献   

15.
Oxidants of significance to human health include ozone, nitrogen dioxide, and peroxyacetylnitrate. All of these compounds are involved in complex photochemical reactions which makes quantification and prediction of their individual health effects difficult. Ozone causes trauma to lung tissues and interferes with enzyme systems in the lungs and other tissues causing a broad range of symptoms. Measurable health impacts can occur at concentrations as low as 390 μg/m3. Acute effects of ozone exposure are reversible at normal urban concentrations (80–120 μg/m3). A special problem of concern, however, is increased susceptibility to infectious diseases contracted through the lungs. Nitrogen dioxide also causes trauma to lung tissues and interferes with enzyme systems. Measurable impacts can occur at concentrations as low as 100 μg/m3, but recovery is rapid and it is not known whether repeated exposures at this level have cumulative effects or predispose the lungs to permanent damage. Chronic exposure of laboratory animals to higher nitrogen dioxide levels can cause emphysema-like conditions and reduction in resistance to respiratory infection. Epidemiological studies of children in houses with gas stoves confirm the finding of reduced resistance to respiratory infection. The U.S. EPA estimates that health effects may occur in young children exposed to concentrations in excess of 280 to 560 μg/m3 one-hour average. These concentrations occur routinely in houses having gas stoves. Peroxyacetylnitrate is a powerful eye irritant in photochemical smog. Other health effects are similar to those of ozone, but less important because of the relatively low concentrations of this pollutant compared to other oxidants.  相似文献   

16.
Radon measurements were performed in secondary schools in the Oke-Ogun area, South-west, Nigeria, by solid state nuclear track detectors (SSNTDs). About seventy CR-39 detectors were distributed in 35 high schools of the Oke-Ogun area. The CR-39 detectors were exposed in the schools for 3 months and then etched in NaOH 6 N solution at 90 °C for 3 h. The tracks were counted manually at the microscope and the radon concentration was determined at the Radioactivity Laboratory, Department of Physics, University of Trieste, Trieste, Italy. The overall average radon concentration in the surveyed area was 45 ± 27 Bq m−3. The results indicate no radiological health hazard. The research also focused on parameters affecting radon concentrations such as the age of the building in relation to building materials and floor number of the classrooms. The results show that radon concentrations in ground floors are higher than in upper floors.  相似文献   

17.
On 15 dates, 5000 measurements of carbon monoxide (CO) were made in downtown commercial settings in four California towns and cities (San Francisco, Palo Alto, Mountain View, and Los Angeles), using personal exposure monitoring (PEM) instruments. Altogether, 588 different commercial settings were visited, and indoor and outdoor locations were sampled at each setting. On 11 surveys, two CO PEM's were carried about 0.15–6 m apart, giving 1706 pairs of observations that showed good agreement: the correlation coefficient was r = 0.97 or greater, and the average difference was less than 1 ppm (μL/L) by volume. Of 210 indoor settings (excluding parking garages), 204 (97.1%) had average CO concentrations less than 9 ppm (μL/L); of 368 outdoor settings, 356 (96.7%) had average CO concentrations less than 9 ppm (μL/L). For a given date and commercial setting, CO concentrations were found to be relatively stable over time, permitting levels to be characterized by making only brief visits to each setting. The data indicate that most commercial settings experience CO concentrations above zero indoors, because CO tends to seep into buildings from vehicular emissions outside. Levels in these locations usually are not above 5 ppm (μL/L) and seldom are higher than the U.S. health-related ambient air quality standards for CO. However, indoor garages and buildings with attached indoor parking areas are exceptions and can experience relatively high CO concentrations.  相似文献   

18.
Twenty-one years after the Chernobyl accident, lichen and moss samples were collected from the Ordu province, which was already chosen for a related study some years ago. It was observed that 137Cs activity concentration ranged from 31 to 469 Bq kg−1 in the moss and from 132 to 1508 Bq kg−1 in the lichen samples. The decrease of the activity concentrations in the present measurements (2007) relative to those in 1997 (over a period of 10 y) indicated ecological half-lives between 1.8 and 10.4 y for the moss and between 2.1 and 13.7 y for the lichen samples. It was observed that 137Cs was still eminent in the area studied. Moreover, 40K activity concentrations and K element concentrations were measured and their relationships were discussed.  相似文献   

19.
The ARGOS decision support system is currently being extended to enable estimation of the consequences of terror attacks involving chemical, biological, nuclear and radiological substances. This paper presents elements of the framework that will be applied in ARGOS to calculate the dose contributions from contaminants dispersed in the atmosphere after a ‘dirty bomb’ explosion. Conceptual methodologies are presented which describe the various dose components on the basis of knowledge of time-integrated contaminant air concentrations. Also the aerosolisation and atmospheric dispersion in a city of different types of conceivable contaminants from a ‘dirty bomb’ are discussed.  相似文献   

20.
To collect regional information on internal levels of pollutants in humans in Flanders, 1196 mother–child pairs were systematically recruited in 2002–2003 via 25 maternities across Flanders. Cd, Pb, PCB congeners 118, 170, 138, 153 and 180, p,p′-DDE — a key metabolite of DDT- and hexachlorobenzene (HCB) were measured in cord blood or plasma. Cd was detected in 64% of the samples (geometric mean 0.21 µg/L cord blood). p,p′-DDE (110 ng/g plasma lipids) and Pb (14.7 µg/L blood), were measurable in nearly all samples. The individual PCB congeners could be detected in 40 to 81% of the newborns (138 + 153 + 180 = 64.4 ng/g plasma lipids). HCB (18.9 ng/g plasma lipids) and dioxin-like compounds measured by DR-CALUX® (23 pg CALUX-TEQ/g lipids) were above detection limit in more than 75% of the samples. Age and smoking habits of the mothers, did not influence the cord blood Pb and Cd levels. The organochlorines increased 4 to 9% per year of the mother's age (partial R= 0.05 to 0.22). Mothers had 2.6% less PCBs in cord blood (partial R= 0.02) for each unit increase in pre-pregnancy BMI. Season of delivery, breastfeeding previous children or consumption of local dairy products, were minor determinants. Up to 20% of the variability in organochlorine concentrations was explained by residence area. It was concluded that the place of birth in Flanders is an important determinant of the load of pollutants measured at the start of life. This underlines the validity of human biomonitoring on (relatively) small geographical scale.  相似文献   