1.
Polychlorinated naphthalenes (PCNs), short-chain chlorinated paraffins (SCCPs) and polychlorinated biphenyls (PCBs) were analysed in marine sediment samples collected from the coastal area of Barcelona (Spain) and near of a submarine emissary coming from a waste water treatment plant located at the mouth of the Besòs River (Barcelona). An integrated sample treatment based on Soxhlet extraction followed by a simple clean-up with Florisil and graphitized carbon cartridge was employed. Gas chromatography coupled to ion-trap tandem mass spectrometry (GC-MS/MS) and gas chromatography-mass spectrometry in electron capture negative ionization mode, were used for PCN and SCCP determinations, respectively, while for PCB analysis gas chromatography with electron capture detection (GC-ECD) was used. The method developed provided low limits of detection (0.001-0.003 ng g(-1) dry weight (dw) for PCNs, 1.8 ng g(-1) for SCCPs and 0.006-0.014 ng g(-1)dw for PCBs) and good run-to-run precisions (lower than RSD 8%) for the analysis of sediment samples. Concentration levels ranging from 0.17 to 3.27 ng g(-1)dw for PCNs, between 0.21 and 1.17 microg g(-1)dw for SCCPs, and from 2.33 to 44.00 ng g(-1) (dw) for PCBs, were found in the coastal sediments, while for samples collected near to the submarine emissary higher levels (from 2.02 to 6.56 ng g(-1)dw for PCNs, between 1.25 and 2.09 microg g(-1)dw for SCCPs and from 22.34 to 37.74 ng g(-1)dw for PCBs) were obtained. The results obtained provide new data about the occurrence of PCN and SCCP in the coastal area of Barcelona.  相似文献   

2.
Koh IO  Rotard W  Thiemann WH 《Chemosphere》2002,47(2):219-227
Chlorinated paraffins (CPs) pose a major risk in the environment, due to their wide application, to their persistence, to their carcinogenic potential, and in view of the fact, that they cannot be easily identified. Various commercial cutting fluids and sealing materials were analysed for CPs with carbon skeleton reaction gas chromatography (GC) and flame ionization detection. CPs are simultaneously dechlorinated and hydrogenated to the corresponding alkanes with Pd catalyst material in the GC injector. With this method, the carbon chain length of commercial technical CPs was determined. In six of sixteen sealing materials we found five short and one medium chain length polychlorinated paraffins in percentages of 9-16% (w/w). In five cutting fluids we found predominantly medium to long chain length chloroparaffins with percentages of 2.5-31% (w/w), only one fluid contained short chain CPs.  相似文献   

3.
Persistent organic pollutants (POPs), organochlorine pesticides and polychlorinated biphenyls (PCBs), listed as per the Stockholm Convention (alpha -HCH, beta -HCH, gamma -HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, p,p'-DDE, aldrin, endrin, dieldrin, PCBs 28, 52, 118, 138, 153, and 180), were analyzed in municipal solid waste (MSW) compost samples from three different Brazilian composting plants located in three S?o Paulo State cities: Araras, Araraquara and S?o Paulo (Vila Leopoldinha). Quantitative and qualitative analyses were carried out using gas chromatography electron capture detection (GC-ECD) and gas chromatography mass spectrometry (GC-MS) (Ion Trap, electron impact ionization), respectively. The samples were analyzed in triplicate and the target POPs were not detected by GC-ECD. Twelve pollutants were identified in two samples when qualitative analysis (GC-MS) was used (beta -HCH, gamma -HCH, p,p'-DDT, o,p'-DDT, p,p'-DDD, and p,p'-DDE, PCBs 28, 118, 138, 153 and 180). The composting process has advantages such as urban solid waste reduction and landfill life-span increase, however the MSW compost quality, which can be utilized for agricultural purposes, should be evaluated and be controlled. This kind of study is the first step in making available information to answer questions regarding MSW compost for sustainable agricultural use, such as the pollutants accumulation in soil and in groundwater, and plants uptake.  相似文献   

4.
Liu L  Cheng J  Matsadiq G  Li JK 《Chemosphere》2011,83(10):1307-1312
A novel and simple method based on polymer monolith microextraction (PMME) coupled to gas chromatography with electron-capture detection (GC-ECD) was developed for the determination of six polychlorinated biphenyls (PCBs) residues in water samples. The proposed method used poly-(methyl methacrylate-co-ethylene dimethacrylate) (MMA-co-EDMA) monolith as extraction media. Several factors affecting experiments such as sample flow rate, sample volume, the type of eluent, eluent volume, eluent flow rate, effect of salt addition and carry over effect were investigated and optimized systematically. The limits of detection (LODs) for six PCBs were 0.028-0.043 ng mL−1 in water samples. The intra-day and inter-day precisions (R.S.D.) were less than 9.2% and 9.6%, respectively. The proposed method was successfully applied to the determination of six PCBs in tap water, lake water and industrial waste water and the trueness has been evaluated by recovery experiments. The obtained relative recoveries were in the range of 63.3-105.6%.  相似文献   

5.
J. Lawrence  F. Onuska  R. Wilkinson  B.K. Afghan   《Chemosphere》1986,15(9-12):1085-1090
This communication describes a simple isolation/extraction procedure for fish and sediment samples based on acid digestion, gel permeation chromatography, trisodium phosphate treatment, micro-alumina chromatography and carbon fibre colum chromatography. The cleaned extracts are analysed for tetrachloro dibenzo-p-dioxins using GC-ECD screening and HRGC-MS (multiple ion dection) confirmation.  相似文献   

6.
对环境水样中百菌清农药残留进行了SPE-GC分析方法研究。环境水样通过Florisil柱富集、净化,3 mL乙酸乙酯洗脱,GC-ECD进行分析检测。实验表明,百菌清农药残留在0.01~10 mg/L范围内线性关系良好,相关系数为0.9993。外标法定量,检出限为0.0035 mg/L,对实际水样进行加标回收,回收率范围在93.47%~100.14%之间,6次重复测定相对标准偏差在3.97%~4.96%之间,并将方法应用于周边环境地表水的检测。该方法具有简便,快速,准确,灵敏度高等特点,能满足环境水样中农药残留分析要求。  相似文献   

7.
Conifer needles are used for the monitoring of atmospheric persistent organic pollutants. The objective of the present study was to develop a method for the detection of airborne chlorinated paraffins (CPs) using spruce needles as a passive sampler. The method is based on liquid extraction of the cuticular wax layer followed by chromatographic fractionation and detection of CPs using two different GCMS techniques. Total CP concentrations (sum of short (SCCP), medium (MCCP) and long chain CPs (LCCP)) were determined by EI-MS/MS. SCCP and MCCP levels as well as congener group patterns (n-alkane chain length, chlorine content) could be evaluated using ECNI-LRMS. For the first time, data on environmental airborne CPs on spruce needles taken within the Monitoring Network in the Alpine Region for Persistent and other Organic Pollutants (MONARPOP) are presented providing evidence that spruce needles are a suitable passive sampling system for the monitoring of atmospheric CPs.  相似文献   

8.
Reth M  Zencak Z  Oehme M 《Chemosphere》2005,58(7):847-854
This study presents the first investigation of concentrations and congener group patterns of short- (SCCPs) and medium-chain chlorinated paraffins (MCCPs) in fish from the North and Baltic Sea. North Sea dab, cod and flounder were studied. High resolution gas chromatography (HRGC) coupled to low resolution mass spectrometry (LRMS) in the electron capture negative ionization mode (ECNI) was employed. Good linearity (R2>0.993, 7 measuring points) was achieved between 1 and 100 ng/g of CP mixtures for SCCPs and MCCPs. The limits of detection were 0.5-1 ng/microl of CP mixture for the major congener groups of SCCPs and MCCPs. A clean-up comprising fat extraction, adsorption chromatography on silicagel impregnated with concentrated sulphuric acid and adsorption chromatography on Florisil was employed to avoid interferences from other polychlorinated compounds. Recoveries of CPs in spiked samples ranged between 80% and 100%. Accuracy was controlled with spiked samples and deviated not more than 10% from the expected values. Quantification was performed with standards of an average chlorine content as close as possible to that of the samples (SCCPs: 59-62%, MCCPs: 53-58%). SCCP concentrations ranged between 19 and 286 ng/g liver wet weight (ww), MCCP concentrations were comparable with a range of 25-260 ng/gww. Congener group patterns were also determined and discussed. In samples from the Baltic Sea the SCCP congener pattern was similar to that of commercial SCCP mixtures or C13 congeners were most abundant. In samples from the North Sea a higher relative abundance of C10 congeners was observed.  相似文献   

9.
Studies were conducted to analyze the residue of commonly used pesticides viz. methyl parathion, chloropyrifos, endosulfan, cypermethrin, fenvalerate, carbendazim, imidacloprid and carbaryl in mango, Dashehari variety, integrated pest management (IPM) and non-IPM samples were collected from the IPM and non-IPM orchards, Lucknow, India. We also present a method for the simultaneous determination of these pesticides in mango samples. Residues of methyl parathion, chloropyriphos, endosulfan, cypermethrin, fenvalerate were extracted from the samples with acetone: cyclohexane: ethyl acetate in the ratio 2:1:1 followed by cleanup using neutral alumina. Analysis was performed by gas chromatography-electron capture detector (GC-ECD) with a megabore column (OV-1). Residues of carbendazim, imidacloprid and carbaryl were extracted with acetone and after cleanup, analysis was performed by high performance liquid chromatography (HPLC) using photo diode array (PDA) detector. Recoveries of all the pesticides ranged between 72.7-110.6%, at 0.1 and 1.0 microg g(-1) level of fortification. The residues detected in non-IPM samples of mango were found to be below the prescribed limits of maximum residue limit (MRL) while IPM samples were free from pesticide residues.  相似文献   

10.
This paper documents the occurrence of polychlorinated biphenyl (PCB) and hexachlorocyclohexane (HCH) deposition inferred from a sedimentary record exposed in a salt-marsh trench in South-Central Chile. Sediments were carefully collected every 1 cm from the trench wall. The samples were analyzed for PCBs, HCHs, 137Cs, organic carbon and grain size. The 137Cs fallout and the sedimentary signature left by the 1960 Chilean tsunami were used as temporal markers to estimate the stratigraphic chronology and the sedimentation rates. PCBs were quantified by gas chromatography with electron capture detection (GC-ECD), and positive samples were confirmed by gas chromatography and mass spectrometry detection (GC-MS). Based on these results, PCBs and HCHs deposition over the last 40 years was estimated. No PCBs were detected below the tsunami signature. Total concentrations ranged from undetectable (ND) to 32 ng/g d.w. for PCBs and from undetectable (ND) to 1.29 ng/g d.w. for HCHs. The highest PCB concentrations were found in the upper 7 cm of the core. Even though PCBs were banned in 1982 as electrical fluids in Chile, total estimated PCB fluxes have increased approximately 20 times during the last 40 years: from undetectable values to 102.6 ng/cm2/year, reflecting that PCBs are still in use and being released into the environment.  相似文献   

11.
Studies were conducted to analyze the residue of commonly used pesticides viz. methyl parathion, chloropyrifos, endosulfan, cypermethrin, fenvalerate, carbendazim, imidacloprid and carbaryl in mango, Dashehari variety, integrated pest management (IPM) and non-IPM samples were collected from the IPM and non-IPM orchards, Lucknow, India. We also present a method for the simultaneous determination of these pesticides in mango samples. Residues of methyl parathion, chloropyriphos, endosulfan, cypermethrin, fenvalerate were extracted from the samples with acetone: cyclohexane: ethyl acetate in the ratio 2:1:1 followed by cleanup using neutral alumina. Analysis was performed by gas chromatography-electron capture detector (GC-ECD) with a megabore column (OV-1). Residues of carbendazim, imidacloprid and carbaryl were extracted with acetone and after cleanup, analysis was performed by high performance liquid chromatography (HPLC) using photo diode array (PDA) detector. Recoveries of all the pesticides ranged between 72.7 – 110.6%, at 0.1 and 1.0 μg g? 1 level of fortification. The residues detected in non-IPM samples of mango were found to be below the prescribed limits of maximum residue limit (MRL) while IPM samples were free from pesticide residues.  相似文献   

12.
This study aims to develop and validate a method to determine OCPs in fish tissues, minimizing the consumption of sample and reagents, by using a modified QuEChERS along with ultrasound, d-SPE and gas chromatography with an electron capture detector (GC-ECD), refraining the pooling. Different factorial designs were employed to optimize the sample preparation phase. The validation method presented a recovery of around 77.3% and 110.8%, with RSD lower than 13% and the detection limits were between 0.24 and 2.88 μgkg?1, revealing good sensitiveness and accuracy. The method was satisfactorily applied to the analysis of tissues from different species of fish and OCPs residues were detected. The proposed method was shown effective to determine OCPs low concentrations in fish tissues, using small sample mass (0.5 g), making the sample analyses viable without the need for grouping (pool).  相似文献   

13.
Chlorinated paraffins (CPs) are toxic, bioaccumulative, persistent, and ubiquitously present in the environment. CPs were analyzed in humus and needle samples, which were taken within the Monitoring Network in the Alpine Region for Persistent and other Organic Pollutants (MONARPOP) at sampling sites of 7 different altitude profiles in the Alps. Gas chromatography combined with electron ionization tandem mass spectrometry (EI-MS/MS) was used for the determination of total CPs (sum of short, medium and long chain CPs). CPs were found in all samples; the concentrations varied between 7 and 199 ng g−1 dry weight (dw) and within 26 and 460 ng g−1 dw in humus and needle samples, respectively. A clear vertical tendency within the individual altitude profiles could not be ascertained. Within all altitude profiles, elevated concentrations were observed in humus samples taken between 700 and 900 m and between 1300 and 1500 m. In the needle samples no similar correlation could be observed due to higher variation of the data.  相似文献   

14.
The complete dechlorination of 1,1-bis(4-chlorophenyl)-2,2,2-trichloroethane (DDT) by a magnesium/palladium bimetallic system has been accomplished. The reaction takes place under ambient temperature and pressure and mild reaction conditions requiring only 0.25 g of magnesium and 0.3% palladium (wt/wt) to drive the dechlorination of 100 microg DDT (50 ppm in 2 ml). The process is both rapid and complete requiring less than 10 min to attain total dechlorination within the detection limit (approximately 10 pg for DDT) of electron capture detection gas chromatography (GC-ECD). The major product formed, as deduced from mass spectrometry (GC-MS) is the hydrocarbon skeleton, 1,1-diphenylethane. This technology may allow for the development of an economic and environmentally benign method of DDT remediation.  相似文献   

15.
We present and compare results obtained from the analysis of polychlorinated biphenyls (PCBs) of a limited number of contaminated soil samples collected in three areas of Basilicata region (south of Italy). The levels of PCBs were evaluated by using two analytical methods: (i) parallel dual-column gas-chromatography with dual electron capture detectors (GC-ECD) and (ii) gas-chromatography coupled to high-resolution mass spectrometry (GC-HRMS) via electron impact ionization (EI) in the multiple ion monitoring mode (MIM, two ions per compound). Two extraction methods prior to sample cleanup were also examined: microwave-assisted extraction (MAE) and ultrasonic-assisted extraction (UAE). The MAE was the extraction procedure adopted using acetone/n-hexane (1:1, v/v) as it is mainly characterized by higher sample throughput and allowed reduced consumption of organic solvents. While extraction and analysis of spiked soil samples showed the applicability of both methods, systematic differences between the results were obtained for the sum of PCBs as a result of some non-detected congeners by GC-ECD compared with GC-HRMS. Indeed, high resolution MS using EI mode (electron energy 40eV) with a resolving power of 10,000 provides additional information about the contamination pattern. The GC-ECD screening of 11 soil samples led to just one sample non-compliant to as it was close to the guide value for soils fixed by the Italian legislation (i.e., 60ppb for private or urban soil). Using GC-HRMS, the amount of all PCBs found ranged from 5.4 to 127ppb with five soil samples non-compliant to the guide value. The number of identified congeners ranged from 1 to 9 and 9 to 18 using dual-column GC-ECD and GC-HRMS, respectively.  相似文献   

16.
Persistent organic pollutants (POPs), organochlorine pesticides and polychlorinated biphenyls (PCBs), listed as per the Stockholm Convention (α -HCH, β -HCH, γ -HCH, p,p′-DDT, o,p′-DDT, p,p′-DDD, p,p′-DDE, aldrin, endrin, dieldrin, PCBs 28, 52, 118, 138, 153, and 180), were analyzed in municipal solid waste (MSW) compost samples from three different Brazilian composting plants located in three São Paulo State cities: Araras, Araraquara and São Paulo (Vila Leopoldinha). Quantitative and qualitative analyses were carried out using gas chromatography electron capture detection (GC-ECD) and gas chromatography mass spectrometry (GC-MS) (Ion Trap, electron impact ionization), respectively. The samples were analyzed in triplicate and the target POPs were not detected by GC-ECD. Twelve pollutants were identified in two samples when qualitative analysis (GC-MS) was used (β -HCH, γ -HCH, p,p′-DDT, o,p′-DDT, p,p′-DDD, and p,p′-DDE, PCBs 28, 118, 138, 153 and 180). The composting process has advantages such as urban solid waste reduction and landfill life-span increase, however the MSW compost quality, which can be utilized for agricultural purposes, should be evaluated and be controlled. This kind of study is the first step in making available information to answer questions regarding MSW compost for sustainable agricultural use, such as the pollutants accumulation in soil and in groundwater, and plants uptake.  相似文献   

17.
An inter-laboratory round robin analysis of toxaphene in a National Institute of Standards Cod Liver Oil #1588 was carried out. Analysis was performed by GC-ECD, electron capture negative ion GCMS (ECNI GCMS) and electron impact GC/MS in high resolution single ion monitoring mode (EI-HRSIM). Results of the analyses by GC-ECD, ECNI and HRSIM were 4.22±2.45 ppm, 3.95±1.57 ppm, and 2.35±0.06 ppm respectively. Due to the wide inter-laboratory variation in workup, GC conditions, detection method, and quantitation algorithms used, no one set of factors stood out as the cause of the variation in results.  相似文献   

18.
Ferrari S  Mandel F  Berset JD 《Chemosphere》2002,47(2):173-182
An analytical method was developed to determine quantitatively 1-hydroxypyrene (OHP) in bovine urine samples. The procedure includes an enzymatic hydrolysis to cleave the conjugated metabolite, an enrichment step using solid phase extraction with a non-polar rinse step and elution with dichloromethane. A final clean-up on silicagel was performed before high-performance liquid chromatography (HPLC) analysis and fluorescence detection. Alternatively, HPLC and electrospray ionization in the negative ion mode applying selective ion monitoring acquisition revealed to be a highly sensitive detection method allowing the quantitation of low pg of OHP in the urine samples. The method was successfully applied to the determination of OHP in bovine urine samples from animals living in urban and rural areas. Urine concentrations of OHP were significantly higher (median 8.6 microg l(-1)) of bovines living close to a highway.  相似文献   

19.
固相微萃取-气相色谱法测定饮用水及其水源水中的氯酚   总被引:15,自引:0,他引:15  
利用固相微萃取(SPME)-气相色谱法(GC)联用技术测定饮用水及其水源水中的氯酚.优化萃取温度、萃取平衡时间、酸度、离子强度等实验条件.所建方法简便、精确,自来水和太湖水中均检测到氯酚。  相似文献   

20.
A simple, very efficient method is presented for routine analysis of herbicide Krovar I (active components bromacil and diuron) in water and soil samples. Water samples were extracted by liquid-liquid extraction with dichloromethane (DCM) as extraction solvent. For soil samples two different extraction techniques were compared: microwave-assisted solvent extraction and a shaking technique using a platform shaker. Extracts were analyzed by high performance liquid chromatography using a water:methanol gradient. Liquid chromatography was coupled with atmospheric pressure chemical ionization mass spectrometry (LC-APCI-MS) for quantification of bromacil and diuron. Optimization of the APCI-MS was done by using standards in the flow injection analysis mode (FIA). Method detection limit for liquid samples for bromacil is 0.04 microg L(-1) and for diuron 0.03 microg L(-1). Method detection limit for soil samples is 0.01 microg g(-1) dry weight for both compounds. Results of analysis of field samples of water and soil are also presented.  相似文献   