首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Degradation rates and removal efficiencies of Metronidazole using UV, UV/H2O2, H2O2/Fe2+, and UV/H2O2/Fe2+ were studied in de-ionized water. The four different oxidation processes were compared for the removal kinetics of the antimicrobial pharmaceutical Metronidazole. It was found that the degradation of Metronidazole by UV and UV/H2O2 exhibited pseudo-first order reaction kinetics. By applying H2O2/Fe2+, and UV/H2O2/Fe2+ the degradation kinetics followed a second order behavior. The quantum yields for direct photolysis, measured at 254 nm and 200-400 nm, were 0.0033 and 0.0080 mol E(-1), respectively. Increasing the concentrations of hydrogen peroxide promoted the oxidation rate by UV/ H2O2. Adding more ferrous ions enhanced the oxidation rate for the H2O2/Fe2+ and UV/H2O2/Fe2+ processes. The major advantages and disadvantages of each process and the complexity of comparing the various advanced oxidation processes on an equal basis are discussed.  相似文献   

2.
In this paper, a comparison of various advanced oxidation processes (O3, O3/UV, H2O2/UV, O3/H2O2/UV, Fe2+/H2O2) and chemical treatment methods using Al2(SO4)3.18H2O, FeCl3 and FeSO4 for the chemical oxygen demand (COD) and color removal from a polyester and acetate fiber dyeing effluent is undertaken. Advanced oxidation processes (AOPs) showed a superior performance compared to conventional chemical treatment, which maximum achievable color and COD removal for the textile effluent used in this study was 50% and 60%, respectively. Although O3/H2O2/UV combination among other AOPs methods studied in this paper was found to give the best result (99% removal for COD and 96% removal for color), use of Fe2+/H2O2 seems to show a satisfactory COD and color removal performance and to be economically more viable choice for the acetate and polyester fiber dyeing effluent on the basis of 90% removal.  相似文献   

3.
Degradation of dyes in aqueous solutions by the Fenton process   总被引:3,自引:0,他引:3  
Xu XR  Li HB  Wang WH  Gu JD 《Chemosphere》2004,57(7):595-600
Degradation of 20 different dyes in aqueous solutions by the Fenton process was performed. These dyes include 6 types: acidic, reactive, direct, cationic, disperse and vat dyes. The former four types of dyes were decolorized and their TOC values were decreased greatly, while the color and TOC removals of the latter two types were lower. The catalytic activities of four metal ions on the degradation efficiencies of Vat Blue BO, which was chosen as a model dye because of its lowest color and TOC removals, were compared in the dark and under the ultraviolet light irradiation. The catalytic ability of different metals was Fe2+>Cu2+>Mn2+>Ag+ in the dark, and the same sequence was obtained under irradiation condition with greater degradation efficiency. Furthermore, the efficiencies of three oxidation processes, including H2O2/UV, Fe2+/H2O2 and Fe2+/H2O2/UV were compared. The results showed that the oxidation by Fe2+/H2O2/UV was the strongest, and even greater than the arithmetic sum of the other two processes, which suggests the synergistic effect of ultraviolet and ferrous ions on the degradation reaction.  相似文献   

4.
The photodegradation of monuron (3-(4-chlorophenyl)-1,1-dimethylurea) in aqueous solutions under simulated solar irradiation has been conducted by different advanced oxidation processes (UV/H(2)O(2), UV/H(2)O(2)/Fe(2+), UV/H(2)O(2)/TiO(2), UV/TiO(2), dark H(2)O(2)/Fe(3+)). The degradation rates were always higher for the homogeneous catalysis in photo-Fenton reactions (UV/H(2)O(2)/Fe(2+)) compared to the heterogeneous photocatalytic systems (TiO(2)/UV and UV/H(2)O(2)/TiO(2)). Optimal concentrations of Fe(2+) and H(2)O(2) for the abatement of the herbicide in the photo-Fenton system were found to be 1 mM Fe(II) and 10 mM H(2)O(2). Several intermediary products were identified using large volume injection micro-liquid chromatography with UV detection (mu-LC-UV), mu-LC-MS and GC-MS techniques and a degradation mechanism has been proposed.  相似文献   

5.
不同高级氧化法对水中低浓度药物甲硝唑降解过程的比较   总被引:3,自引:0,他引:3  
采用UV、H2O2、UV/H2O2、Fenton、UV/Fenton和UV/TiO2方法,对水中低浓度的药物甲硝唑进行降解。通过HPLC和UV-Vis光谱得到的甲硝唑去除率。详细讨论了Fe2+、TiO2和H2O2的初始浓度以及溶液的初始pH值对降解效率的影响。结果表明,UV/Fenton和UV/TiO2 2种系统对水中低浓度甲硝唑均有很好的去除效果,但前者的光催化效率更高。在甲硝唑浓度=6 μmol/L,H2O2和Fe2+的初始浓度分别为0.5 mg/L和2.94 μmol/L,pH=4的条件下,UV/Fenton方法对甲硝唑水溶液光催化的最佳效率为95.8%。  相似文献   

6.
BACKGROUND: The spent waste of aliphatic chlorinated solvents has caused severe deterioration of groundwater quality. Trichloromethane (TCM), which shows health and toxicological effects on human beings, was selected as a model compound to be dechlorinated through a redox system. METHODS: The Fe0-based system including Fe0/H2O, Fe0/UV, Fe0/H2O2, and Fe0/UV/H2O2 was explored to evaluate its performance in dechlorinating TCM. H2O2 was dosed at later reaction time points to initiate Fenton or photo-Fenton reactions. The first two systems demonstrate the reductive dechlorination of TCM by Fe0-released electrons, while the latter two show dechlorination of TCM by both electron reduction and hydroxyl radical oxidation. The system parameters of TCM remaining, Cl- buildup, Fe2+ accumulation, H2O2 residue, and ORP were measured to describe different redox characteristics of TCM dechlorination. The Cl- buildup was used as a way to describe the degree of TCM dechlorination in an open reaction system. RESULTS: Reductive dechlorination efficiencies of TCM were 5% and 6% for the systems of Fe0/H2O and Fe0/UV, respectively. In contrast, the Fe/H2O2 and Fe0/UV/H2O2 systems were capable of dechlorinating TCM reductively and oxidatively by 14% and 15%, respectively. The presence of UV light was found to retard the dissolution of Fe2+, but it enhanced the rate of chloride buildup, based on the comparison of Fe0/H2O and Fe0/UV systems. In addition, WV irradiation plays only a minor role in the Fe0/UV/H2O2 system, in view of TCM dechlorination. Application of small amount of H2O2 results in the increase of Fe2+ accumulation rate in the Fe0/H2O2 system. CONCLUSIONS: TCM was dechlorinated mostly through post Fenton oxidation; reductive reaction represents a less efficient way to dechlorinate TCM. The efficiencies of overall TCM dechlorination for the two systems of Fe0/H2O2 and Fe0/UV/ H2O2 are comparable to each other, and this implies that the presence of UV irradiation imposes no significant enhancement. RECOMMENDATIONS AND OUTLOOKS: It is highly recommended to initiate effective redox dechlorination of TCM with the system of Fe0/H2O2, where the H2O2 in excess is applied at a later reaction time point.  相似文献   

7.
三烯丙基异氰脲酸酯(TAIC)作为一种性质稳定难于生化降解的化合物而危害环境,其生产废水不容易被电化学、高级氧化或吸附方法得以高效处理。采用一种简易高效的碱性破乳法结合Fenton氧化工艺来处理TAIC生产废水,并考察了碱性破乳中的反应温度和pH值以及Fenton氧化中的H2O2投加量、n(H2O2)/n(Fe2+)、反应时间和反应pH值对处理效果的影响。结果表明:在最佳的碱性破乳条件(反应温度为60℃,pH值为12)下,COD去除率可以达到46.4%以上,TAIC去除率可以达到70.3%以上,同时可以使浊度和盐度大幅度降低;在最佳的Fenton氧化条件(H2O2投加量为7 g L-1,n(H2O2)/n(Fe2+)为3:1,反应时间为40 min,初始pH值为3.5)下,COD去除率可以达到49.6%,B/C比提高到了0.36。碱性破乳法可以使TAIC直接从水中大量析出,是一种绿色环保的清洁工艺。该组合工艺可以有效地削减后续进入生化反应的负荷。  相似文献   

8.
采用超声波(US)、紫外光(UV)和Fenton联合降解硝基苯,初步探讨了其作用规律。研究结果表明, UV可以促进双氧水转化自由基的效率,而US同时具有强化传质作用和超声氧化作用,两者均能够强化Fenton氧化硝基苯的降解过程。正交实验结果表明,H2O2初始浓度是硝基苯降解和矿化的最显著影响因素,反应时间和超声功率是矿化的显著影响因素。最佳反应条件为:H2O2 500 mg/L、Fe2+10 mg/L、反应时间60 min、超声波功率100 W,此时,硝基苯完全降解,TOC去除率达到73.0%。Fenton、UV/Fenton和US/UV/Fenton降解硝基苯过程均符合伪一级反应动力学模式,反应速率常数分别为3.37×10-2、3.81×10-2和5.10×10-2min-1。  相似文献   

9.
为了探索络合态重金属废水的处理方法,采用UV/Fenton氧化技术处理EDTA-Cu-Ni模拟废水,主要研究了Fe2+投加量、H2O2投加量、初始pH和UV光照时间等因素对COD、Cu2+和Ni2+去除效果的影响及机理。结果表明,随着Fe2+和H2O2投加量以及初始pH的升高,COD、Ni2+的去除率先升后降,Cu2+的去除率则在升高后趋于稳定;随着UV光照时间的增加,COD、Cu2+、Ni2+去除效率均呈上升趋势并逐渐达到平衡。结合成本和效率考虑,得出最佳处理条件为:Fe2+投加量为10 mmol·L-1,H2O2投药量为600 mmol·L-1,反应初始pH为3.0,UV光照时间为120 min。在UV/Fenton体系中,UV光照能增强Fenton反应的去除效率,异丙醇对反应的抑制说明羟基自由基在处理过程中是重要的活性物种。  相似文献   

10.
In this study, advanced oxidation technologies, namely Fenton Process (FP), Fenton-Like Process (FLP), ozonation (O3) and O3/H2O2 processes, were applied to synthetic wastewater containing 3-indolebutyric acid (IBA). The effectiveness of each process was investigated at different pH values, Fe(+2), Fe(+3), O3 and H2O2 concentrations with respect to the removal efficiencies for chemical oxygen demand (COD) and total organic carbon (TOC). The best removal efficiencies were seen at pH 3 and 2 mM Fe concentration in both FP and FLP, in which the optimum H2O2 concentrations were 6 mM for FP and 10 mM for FLP. Optimum process conditions were pH 12 for the O3 process, pH 9 for the O3/H2O2 process and 1:1 O3/H2O2 molar ratio. The highest COD removal efficiency was 86 percent, obtained in the O3/H2O2 process and the highest TOC removal efficiency was obtained at 77 percent in the FP.  相似文献   

11.
Xu XR  Zhao ZY  Li XY  Gu JD 《Chemosphere》2004,55(1):73-79
Degradation of methyl tert-butyl ether (MTBE) in aqueous solution by Fenton's reagent (Fe2+ and H2O2) was investigated. Effects of reaction conditions on the oxidation efficiency of MTBE by Fenton's reagent were examined in batch experiments. Under optimum conditions, 15 mM H2O2, 2 mM Fe2+, pH 2.8 and room temperature, the initial 1 mM MTBE solution was reduced by 99% within 120 min. Results showed that MTBE was decomposed in a two-stage reaction. MTBE was first decomposed swiftly based on a Fe2+/H2O2 reaction and then decomposed somewhat less rapidly based on a Fe3+/H2O2 reaction. The detection of Fe2+ also supported the theory of the two-stage reaction for the oxidation of MTBE by Fenton's reagent. The dissolved oxygen in the solution decreased rapidly in the first stage reaction, but it showed a slow increase in the second stage with a zero-order kinetics. A reaction mechanism involving two different pathways for the decomposition of MTBE by Fenton's reagent was also proposed. Chemicals including tert-butyl formate, tert-butyl alcohol, methyl acetate and acetone were identified to be the primary intermediates and by-products of the degradation processes.  相似文献   

12.
以某电镀厂水回用系统产生的高盐有机废水为对象,对比研究了Fenton、UV-Fenton等工艺去除COD性能,考察了初始pH、H2O2投加量、Fe2+与H2O2摩尔比、反应时间等参数对处理效果的影响。结果表明:UV-Fenton工艺的最佳条件为初始pH=3.0,H2O2的投加量3 mmol/L,RFe2+:H2O2=1:1,反应时间30 min;在此条件下,COD去除率可达到60%以上,分别较Fenton和UV-H2O2工艺提高23.0%和39.3%。UV-Fenton工艺中,Fenton与UV表现出良好的协同效果,其处理效果较单独Fenton和单独UV处理效果之和高14.7%。UV的引入促进Fe(II)/Fe(Ⅲ)循环,可以提高·OH生成量以及Fe2+与H2O2利用率。UV-Fenton是处理高盐有机废水的可行工艺之一。  相似文献   

13.
在运用芬顿(Fe2+/H2O2)、亚铁离子活化过硫酸钠(Fe2+/PS)和碱活化过硫酸钠(NaOH/PS)3种氧化体系处理典型污染物氯苯(CB)时,发现了3种氧化体系在氧化CB过程中对氯苯酚中间体(4-CP)产生量存在较大差异.探究了氧化剂用量对3种氧化体系降解CB及中间体4-CP的影响,通过总有机碳和游离氯离子浓度变...  相似文献   

14.
胡豫娟  胡奇  高大文 《环境工程学报》2016,10(10):5653-5657
采用Fenton氧化法深度处理经生化降解后的纤维素乙醇废水,考察了初始pH值、Fe2+与H2O2的投加比例(物质的量之比)、H2O2投加量与COD的比例(质量之比)以及反应时间对COD和浊度去除的影响,并通过正交实验确定了反应的最佳条件。研究表明:初始pH值、Fe2+/H2O2、H2O2/COD以及反应时间对深度处理效果有不同程度的影响;在初始pH值为3.0、Fe2+/H2O2为2:3、H2O2/COD为2.8、反应时间为3 h的最佳反应条件下,出水COD为45~56 mg·L-1,浊度为2~3 NTU,达到了纤维素乙醇废水的排放标准。  相似文献   

15.
Different degradation methods have been applied to assess the suitability of advanced oxidation process (AOPs) to promote mineralization of imazethapyr [(RS)-5-ethyl-2-(4-isopropyl-4-methyl-5-oxo-2-imidazolin-2-yl)nicotinic acid], a widely used imidazolinone class herbicide, the persistence of which has been demonstrated in surface and ground waters destined to human uses. Independent of the oxidation process assessed, the decomposition of imazethapyr always followed a pseudo-first order kinetic. The direct UV-irradiation (UV) of the herbicide as well as its oxidation with ozone (O?), and hydrogen peroxide tied to UV-irradiation (H?O?/UV) were sufficiently slow to permit the identification of intermediate products, the formation pathway of which has been proposed. Ozonation joined to UV-irradiation (O?/UV), ozonation joined to titanium dioxide photo-catalysis (TiO?/UV+O?), sole photo-catalysis (TiO?/UV), and photo-catalysis reinforced with hydrogen peroxide-oxidation (TiO?/UV+H?O?) were characterized by a faster degradation and rapid formation of a lot of small molecules, which were quickly degraded to complete mineralization. The most effective oxidation methods were those using titanium dioxide photo-catalysis enhanced either by ozonation or hydrogen peroxide. Most of all, these last processes were useful to avoid the development of dangerous by-products.  相似文献   

16.
The issue of investigations in this study was an application of heterogeneous Fenton-type catalyst, Fe-exchanged zeolite FeZSM5, for the minimization of phenol and overall organic content in the model wastewater. Applied treatment systems included variation of heterogeneous and homogeneous Fenton-type catalyst with and without the assistance of UV irradiation, FeZSM5/H2O2, Fe2+/H2O2/NH4ZSM5, Fe3+/H2O2/NH4ZSM5, UV/FeZSM5/H2O2, UV/Fe2+/H2O2/NH4ZSM5 and UV/Fe3+/H2O2/NH4ZSM5. Processes efficiency was evaluated on the basis of phenol removal, mineralization extent, H2O2 consumption and concentration of iron ions in the bulk after the treatment. By all applied systems, complete phenol removal was achieved in less than 30 min of treatment time. Systems including heterogeneous Fenton-type catalyst showed somewhat lower mineralization efficiency in comparison to the corresponding systems applying homogeneous Fenton-type catalysts and the addition of synthetic zeolite NH4ZSM5. Significantly lower concentration of iron ions in the bulk after the treatment could give these systems, particularly UV/FeZSM5/H2O2, a great advantage over the homogeneous Fenton-type systems.  相似文献   

17.
INTENTION, GOAL, SCOPE, BACKGROUND: Since the intermediate products of some compounds can be more toxic and/or refractory than the original compund itself, the development of innovative oxidation technologies which are capable of transforming such compounds into harmless end products, is gaining more importance every day. Advanced oxidation processes are one of these technologies. However, it is necessary to optimize the reaction conditions for these technologies in order to be cost-effective. OBJECTIVE: The main objectives of this study were to see if complete mineralization of 4-chlorophenol with AOPs was possible using low pressure mercury vapour lamps, to make a comparison of different AOPs, to observe the effect of the existence of other ions on degradation efficiency and to optimize reaction conditions. METHODS: In this study, photochemical advanced oxidation processes (AOPs) utilizing the combinations of UV, UV/H2O2 and UV/H2O2/Fe2+ (photo-Fenton process) were investigated in labscale experiments for the degradation and mineralization of 4-chlorophenol. Evaluations were based on the reduction of 4-chlorophenol and total organic carbon. The major parameters investigated were the initial 4-chlorophenol concentration, pH, hydrogen peroxide and iron doses and the effect of the presence of radical scavengers. RESULTS AND DISCUSSION: It was observed that the 4-chlorophenol degradation efficiency decreased with increasing concentration and was independent of the initial solution pH in the UV process. 4-chlorophenol oxidation efficiency for an initial concentration of 100 mgl(-1) was around 89% after 300 min of irradiation in the UV process and no mineralization was achieved. The efficiency increased to > 99% with the UV/H2O2 process in 60 min of irradiation, although mineralization efficiency was still around 75% after 300 min of reaction time. Although the H2O2/4-CP molar ratio was kept constant, increasing initial 4-chlorophenol concentration decreased the treatment efficiency. It was observed that basic pHs were favourable in the UV/H2O2 process. The results showed that the photo-Fenton process was the most effective treatment process under acidic conditions. Complete disappearance of 100 mgl(-1) of 4-chlorophenol was achieved in 2.5 min and almost complete mineralization (96%) was also possible after only 45 min of irradiation. The efficiency was negatively affected from H2O2 in the UV/H2O2 process and Fe2+ in the photo-Fenton process over a certain concentration. The highest negative effect was observed with solutions containing PO4 triple ions. Required reaction times for complete disappearance of 100 mgl(-1) 4-chlorophenol increased from 2.5 min for an ion-free solution to 30 min for solutions containing 100 mgl(-1) PO4 triple ion and from 45 min to more than 240 min for complete mineralization. The photodegradation of 4-chlorophenol was found to follow the first-order law. CONCLUSION: The results of this study showed that UV irradiation alone can degrade 4-CP, although at very slow rates, but cannot mineralize the compound. The addition of hydrogen peroxide to the system, the so-called UV/H2O2 process, significantly enhances the 4-CP degradation rate, but still requires relatively long reaction periods for complete mineralization. The photo-Fenton process, the combination of homogeneous systems of UV/H2O2/Fe2+ compounds, produces the highest photochemical elimination rate of 4-CP and complete mineralization is possible to achieve in quite shorter reaction periods when compared with the UV/H2O2 process. RECOMMENDATIONS AND OUTLOOK: It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolorization and micropollutant removal. However the most important point is the optimization of the reaction conditions for the process of concern. In such a case, AOPs can be used in combination with a biological treatment systems as a pre- or post treatment unit providing the cheapest treatment option. The AOP applied, for instance, can be used for toxicity reduction and the biological unit for chemical oxygen demand (COD) removal.  相似文献   

18.
The aim of the present study was to analyze and compare the efficacy of UV photodegradation with that of different advanced oxidation processes (O(3), UV/H(2)O(2), O(3)/activated carbon) in the degradation of naphthalenesulfonic acids from aqueous solution and to investigate the kinetics and the mechanism involved in these processes. Results obtained showed that photodegradation with UV radiation (254 nm) of 1-naphthalenesulfonic, 1,5-naphthalendisulfonic and 1,3,6-naphthalentrisulfonic acids is not effective. Presence of duroquinone and 4-carboxybenzophenone during UV irradiation (308-410 nm) of the naphthalenesulfonic acids increased the photodegradation rate. Addition of H(2)O(2) during irradiation of naphthalenesulfonic acids accelerated their elimination, due to the generation of ()OH radicals in the medium. Comparison between UV photodegradation 254 m and the advanced oxidation processes (O(3), O(3)/activated carbon and UV/H(2)O(2)) showed the low-efficacy of the former in the degradation of these compounds from aqueous medium. Thus, among the systems studied, those based on the use of UV/H(2)O(2) and O(3)/activated carbon were the most effective in the oxidation of these contaminants from the medium. This is because of the high-reactivity of naphthalenesulfonic acids with the *OH radicals generated by these two systems. This was confirmed by the values of the reaction rate constant of *OH radicals with these compounds k(OH), obtained by competitive kinetics (5.7 x 10(9) M(-1) s(-1), 5.2 x 10(9) M(-1) s(-1) and 3.7 x 10(9) M(-1) s(-1) for NS, NDS and NTS, respectively).  相似文献   

19.
The homogeneous degradation of the polychlorinated n-alkane, 1,2,9,10-tetrachlorodecane (T4C10), was studied in aqueous solutions of hydrogen peroxide, including Fenton and photo-Fenton reaction conditions. All solutions were adjusted to a pH of 2.8 and an ionic strength of 0.1 M NaClO4 prior to photolysis. T4C10 (2 x 10(-6) M) was substantially degraded by the H2O2/UV system (1.0 x 10(-2) M H2O2), with 60% disappearance in 20 min of irradiation in a photoreactor equipped with 300 nm lamps of light intensity 3.6 x 10(-5) Ein L(-1) min(-1) (established by ferrioxalate actinometry). The reaction produced stoichiometric amounts of chloride ion indicating complete dechlorination of the chlorinated n-alkane. T4C10 degraded very slowly under Fenton (Fe2+/H2O2/dark) and Fenton-like (Fe3+/H2O2/dark) conditions. However, when the same solutions were irradiated, T4C10 degraded more rapidly than in the H2O2/UV system, with 61% disappearance in 10 min of exposure. The rapid degradation is related to the enhanced degradation of hydrogen peroxide to oxidizing *OH radicals under photo-Fenton conditions. Degradation was inhibited in both the H2O2/UV and photo-Fenton systems by the addition of KI and tert-butyl alcohol due to *OH scavenging.  相似文献   

20.
Kwan CY  Chu W 《Chemosphere》2007,67(8):1601-1611
Recent studies have shown that hydrogen peroxide is generated in a ferrioxalate-induced photoreductive reaction, but information about the effect of organic ligands on the photochemical behaviour of ferrous species is limited. The degradation of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) by a ferrous-catalyzed oxidation in the presence of various ligands such as formate, citrate, malelate, oxalate, and ethylenediaminetetra-acetic acid (EDTA) was studied. The experiments were conducted under either dark or irradiated (350n m) conditions. Forty-two percent and 34% of 2,4-D were removed by the Fe(2+)/oxalate/UV and Fe(2+)/citrate/UV processes, respectively, after 30 min of reaction and oxidative intermediates were obtained in both cases. The presence of hydroxylated intermediates suggests that 2,4-D may be attacked by hydroxyl radicals, which are the products of the photo-Fenton-like reaction. As such, hydrogen peroxide was produced by the photolysis of ferrous oxalate or ferrous citrate, referred to hereafter as photogenerated H(2)O(2). As expected, the total removal percentage of 2,4-D jumped to 97% when 1mM of hydrogen peroxide (so-called spiked H(2)O(2)) was externally added to the reaction vessel to initiate the Fe(2+)/oxalate/UV process. Therefore, the treatment of 2,4-D by the Fe(2+)/oxalate/H(2)O(2)/UV system can be operated in two steps: the photolysis of ferrous oxalate first, followed by adding the spiked H(2)O(2) sometime after the commencement of the reaction. A two-phase model has been developed to describe this tandem ferrous-catalyzed photooxidation, which would help to achieve the mineralization of 2,4-D.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号