首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The evaluation of a novel prototype instrument designed for on-site determinations of VOC mixtures found in indoor working environments is described. The instrument contains a miniature multi-stage preconcentrator, a dual-column separation module with pressure-tunable retention capabilities, and an integrated array of three polymer-coated surface acoustic wave sensors. It was challenged with dynamic test-atmospheres of a set of 15 common indoor air contaminants at parts-per-billion concentrations within a stainless-steel chamber under a range of conditions. Vapours were reliably identified at a known level of confidence by combining column retention times with sensor-array response patterns and applying a multivariate statistical test of pattern fidelity for the chromatographically resolved vapours. Estimates of vapour concentrations fell within 7% on average of those determined by EPA Method TO-17, and limits of detection ranged from 0.2 to 28 ppb at 25 degrees C for 1 L samples collected and analyzed in <12 min. No significant humidity effects were observed (0-90% RH). Increasing the chamber temperature from 25 to 30 degrees C reduced the retention times of the more volatile analytes which, in turn, demanded alterations in the scheduling of column-junction-point pressure (flow) modulations performed during the analysis. Reductions in sensor sensitivities with increasing temperature were predictable and similar among the sensors in the array such that most response patterns were not altered significantly. Short-term fluctuations in concentration were accurately tracked by the instrument. Results indicate that this type of instrument could provide routine, semi-autonomous, near-real-time, multi-vapour monitoring in support of efforts to assess air quality in office environments.  相似文献   

2.
A quantitative study of alkylamine permeation through a glove material using Permea-Tec aliphatic amine pads, used for the detection of chemical breakthrough of protective clothing, was performed for triethylamine following a microwave-extraction process and gas chromatographic analysis. Triethylamine exhibited > 99% adsorption on the pads at a spiking level of 729 ng (1.0 ml). Triethylamine showed recoveries from 63 to 90% (RSD < or = 5%) over the range 0.2-1.0 ml (146-729 ng) applied to pads. The ASTM F739 standard and direct permeability testing procedures were used to determine breakthrough times for five protective glove materials using triethylamine as a challenge chemical. Breakthrough times for six protective gloves were determined ranging from 40 s to > 4 h. The quantitative concentration of triethylamine on the pads following permeation through the gloves was also determined, ranging from 101 to 103 ng cm-2 (382-386 ng per pad).  相似文献   

3.
This work describes the development of an instrument for measuring free and total copper in seawater by continuous flow analysis (CFA) with an Orion copper (II) ion selective electrode (CuISE). Sample analysis times are reduced considerably by using an extrapolation technique based on the fitting of an empirical mathematical expression to the electrode time-response curve enabling a prediction of the final equilibrium potential. CuISE measurements in seawater samples containing nanomolar levels of total copper can be very time consuming, and this predictive approach significantly reduces sample analysis time, and improves sample throughput. The time taken to measure pCu in seawater to a precision of +/- 0.1, using conventional potentiometry, varies considerably depending on the condition of the electrode membrane but can be reduced by a factor of 3-6 (typically from 60 to 10 min) by using the extrapolation technique in conjunction with CFA. Details are given of the protocols used for preconditioning the CuISE. The system can be used as a portable instrument for field measurements or for shipboard measurements of free copper in seawater. Extrapolated equilibrium potentials are within +/- 0.5 mV of true steady state values.  相似文献   

4.
Aluminium smelter potrooms are unique in that workplace exposures to hydrogen fluoride (HF), sulfur dioxide (SO2), and particulate matter occur simultaneously for some tasks. The peak exposures to these contaminants are of increasing interest in discovering the etiology of respiratory health effects. While a variety of direct-reading instruments are available for sulfur dioxide and particulate matter, only a few exist for hydrogen fluoride. The sensors in these HF instruments have a cross-sensitivity to sulfur dioxide making it difficult to monitor HF in an environment that also contains SO2. To overcome this problem, we assessed the simultaneous use of two electrochemical instruments: one with a SO2 sensor that does not respond to HF and the second with a hydrogen fluoride sensor that responds to both HF and SO2 in a 1 : 1 ratio, termed 'total acid gas'. The difference in the response between the two instruments should indicate the HF concentration: [HF + SO2] minus SO2 equals HF. The performance characteristics of this sampling train were evaluated in the laboratory through the generation of both HF and SO2 with permeation tubes. The response and recovery times for the SO2 only instrument were acceptable (6 and 15 s, respectively), but the "total acid gas" instrument exhibited both slow response and slow recovery approaching three and six min. The association between the traditional integrated filter sampling method and the direct-reading instrument for SO2 is 0.80 (Spearman's rho). The use of the digital filter strengthens the association between the HF direct-reading instrument and the integrated samples from 0.41 to 0.68.  相似文献   

5.
Distribution of antimony and its inorganic species in soil samples along two traffic routes (A14, Rankweil and S36, Knittelfeld) in Austria was determined, since vehicle emissions are an important anthropogenic source of Sb in soil. The samples were taken along three parallel lines at about 0.2, 2 and 10 m distances from the edge of the road and in two depths range (0-5 and 5-10 cm from the soil surface). The optimized extraction was carried out using 100 mmol L(-1) citric acid at pH 2.08 applying an ultrasonic bath for 45 min at room temperature. Speciation analyses were done using on-line isotope dilution after a chromatographic separation of Sb species. Results of the two traffic routes confirmed significant accumulations of Sb at surface (0-5 cm depth) exceeding the natural background values by more than ten times at the S36 or four times at the A14. Concentrations of the extractable inorganic species decreased to natural background levels within a few meters from the edge of the traffic lane. The predominant Sb species was Sb(V). The Sb(III) concentrations at 5-10 cm depths range are nearly constant with distance from the edges of the two roads. Magnetic susceptibility data of all soil samples show the same distribution pattern as Sb and Sb(V) concentrations along the two traffic roads with an excellent correlation. This is an evidence for an anthropogenic source of Sb such as abrasions of motor vehicles surfaces or braking linings. The input of Sb and its inorganic species at one of the sampling sites (Knittelfeld) in samples taken in 2002 and in those taken recently (2005) was monitored. An increase in Sb (>or=30%), Sb(v)(>or=51%) and Sb(iii)(>or=10%) concentrations was only observed near the edge (相似文献   

6.
A method is presented for the determination of antimony in whole human blood samples with an ICP-MS instrument using a quadrupole mass analyzer. A nitric acid/hydrogen peroxide open digestion procedure was employed for the blood sample treatment and preparation for analysis. The precision and accuracy of the method were evaluated by analyzing several Seronorm trace elements whole blood reference materials. The precision of the method at various antimony levels was better than 4% RSD and the recovery was greater than 92% at all levels. The detection limit, calculated as three times the standard deviation of the blank (3sigma, n= 12), was 0.03 microg L(-1). The method was successfully applied for the determination of antimony in blood samples from school children in rural areas of Kwazulu/Natal, South Africa and adults from Dearborn, Michigan. Blood antimony levels ranged from <0.03 to 3.82 microg L(-1) in children and 1.40 to 4.35 microg L(-1) for adults.  相似文献   

7.
A diffusive sampling method for the determination of gaseous acetic and formic acids, using a radial symmetry diffusive sampler, has been optimised for a 7-day exposure time in this study. Sampling rate determinations were performed on data obtained from a dynamic exposure chamber, simulating the indoor conditions of an empty, closed, room, at room temperature and minimal wind speed. Analysis has been performed by means of ion chromatography. The sampling rates for formic acid concentrations of 128 microg m(-3) and 1248 microg m(-3) were determined to be 91.2 +/- 3.9 ml min(-1) and 111.6 +/- 2.8 ml min(-1), respectively. The acetic acid sampling rate was independent of the concentration in the range 160 microg m(-3)-1564 microg m(-3), and amounted to 97.3 +/- 3.1 ml min(-1). Experimentally determined sampling rates showed deviations of 3% for acetic acid, and 3-21% for formic acid, in relation to theoretically derived values. The blank values were as low as 1.69 +/- 0.07 microg for formic acid and 1.21 +/- 0.14 microg for acetic acid, and detection limits lower than 0.5 microg m(-3) could be achieved, which is an improvement of 98-99% compared to previously validated diffusive sampling methods. This study describes the first step of an extended validation program in which the applicability of these types of samplers for the measurement of organic acids will be validated and optimised for the environmental conditions typical for museum showcases.  相似文献   

8.
The purposes of this study are: (1) to determine whether proficiency analytical test (PAT) materials from the American Industrial Hygiene Association can be used to provide quality data for portable X-ray fluorescence analysis (XRF) of lead in dust wipe surface samples; (2) to provide data to determine whether the on-site analysis of field dust wipe samples by XRF and the laboratory method of inductively coupled plasma emission analysis (ICP) are comparable; and (3) to determine if differences exist between different wipe materials. Several wipes meet the ASTM E1792 performance requirements of lead background level less than 5 microg per wipe, be only one layer thick, yield recovery rates of 80- 120% from spiked samples, remain damp throughout the sampling procedure, and do not contain aloe. The wipes used in this study were Pace Wipes, which are used for the PAT materials, and, for the field samples, Palintest Wipes, which were supplied by the instrument manufacturer, and Ghost Wipes, which are popular because they digest in hot, concentrated acid, so that chemical analysis is simplified. Twenty PAT wipe samples were obtained from four different proficiency test rounds. Surface wipe samples were taken at three different locations representing different industry types. All samples were analyzed using a portable XRF spectrometer and by ICP. Strong linear relationships were found for the analysis of wipe samples by ICP and by portable XRF. For the PAT samples, the results from the ICP and XRF analysis were not statistically equivalent, which indicates a bias in the ICP analysis. The bias was not excessive, since all ICP analyses fell within the acceptable range for the proficiency samples. The good correlation between the proficiency sample reference values and the XRF determinations is not surprising considering similar proficiency samples were used to calibrate the instrument response. Users of this portable XRF analyzer could enroll in the proficiency test program as part of their quality assurance program. For field samples, the relationship was strongest for Palintest wipes, and the values found for all three industries could be combined. However, the results from the ICP and XRF analysis were not statistically equivalent using the correction factor in the calculation algorithm as supplied with the instrument, and a new coefficient was derived. The mean relative error for the XRF analysis versus the ICP analysis was greater than 25%, such that the method falls within the realm of screening procedures. For Ghost Wipe samples, the precision was different for different industries, and the results could not be pooled. Differences between the two wipe materials may be related to the number of folds required for analysis.  相似文献   

9.
We investigated penetration patterns of monomeric and polymeric 1,6-hexamethylene diisocyanate (HDI), experimentally and as part of commercial products, in excised full-thickness human skin at 5, 10, 30, or 60 min after exposure. We observed that both monomeric and polymeric HDI were readily absorbed into the skin and that the clearcoat composition affects the penetration rate of the individual isocyanates. The short-term absorption rates for HDI monomer, biuret, and isocyanurate were determined and used to estimate the exposure time required to reach a body burden equal to the American Conference of Governmental Industrial Hygienists (ACGIH) inhalation threshold limit value (TLV) or Oregon State occupational exposure limit (OEL). Oregon is the only government entity in the United States to promulgate a short-term exposure limit (STEL) for HDI-based polyisocyanates biuret and isocyanurate. Based on these absorption rates for a slow-drying clearcoat after 10 min (1.33 μg cm(-2) h(-1)) or 60 min (0.219 μg cm(-2) h(-1)), we calculated that 6.5 and 40 min dermal exposure, respectively, is required to achieve a dose of HDI equivalent to the ACGIH TLV. For biuret, the time to achieve a dose equivalent to the Oregon OEL for slow-drying clearcoat was much shorter (<31 min) than that for fast-drying clearcoat (618 min). Isocyanurate had the shortest skin absorption times regardless of clearcoat formulation (14 s-1.7 min). These results indicate that the dose received through dermal exposure to HDI-containing clearcoats has a significant potential to exceed the dose equivalent to that received through inhalation exposure at established regulatory limits. A critical need exists to monitor dermal exposure quantitatively in exposed workers, to use proper protective equipment to reduce dermal exposure, and to re-evaluate regulatory exposure limits for isocyanates.  相似文献   

10.
Short-term exposure datasets of 10 workers exposed to organic solvents and daily average exposure datasets of seven workers exposed to cobalt and organic solvents were analyzed in order to clarify whether these exposure data fit an inverse Gaussian distribution. The goodness-of-fit test showed that time-weighted average (TWA) values with averaging times of 30 min, 60 min and 8 hours can be described by an inverse Gaussian distribution, but not those with averaging times of 7.5 min and 15 min.  相似文献   

11.
We present in this paper fifteen years' measurements, from March 1991 to September 2005, of stratospheric NO2 vertical columns measured by a SAOZ zenith-sky visible spectrometer. The instrument spent most of its time at Aberystwyth, Wales, with occasional excursions to other locations. The data have been analysed with the WinDOAS analysis program with low-temperature high-resolution NO2 cross-sections and fitting a slit function to each spectrum. Because of a change in detector in May 1998 there is some uncertainty about the relative changes before and after this date, which are partially constrained by the results of an intercomparison exercise. However, the effect of the Mt Pinatubo aerosol cloud is very evident in the data from 1991-94, with a decrease of 10% in NO2 in the summer of 1992 (the SAOZ was located in Lerwick, Scotland during the winter of 1991-92 and observed very low NO2 values but these cannot be directly compared to the Aberystwyth data). To focus more on interannual and long-term variations in NO2, a seasonal variation comprising an annual and semi-annual component was fitted to the morning and evening twilight separately from 1995 to the present. This fit yielded average NO2 columns of 4.08 x 10(15) cm(-2) and 2.68 x 10(15) cm(-2) for the evening and morning twilight, respectively, with a corresponding annual amplitude of +/-2.08 x 10(15) cm(-2) and +/-1.50 x 10(15) cm(-2). Departures from the fitted curve show a trend of 6% per decade, consistent with that reported elsewhere, for the period 1998-2003, but in the past two years a distinct interannual variation of amplitude of approximately 8% has emerged.  相似文献   

12.
The compositions of commercially available solutions of short chain chlorinated paraffins (SCCP) and technical mixtures were determined by high resolution gas chromatography (HRGC) electron capture negative ionisation (ECNI) combined with low resolution mass spectrometry (LRMS). Differences and similarities in the relative distribution of congeners and homologues were investigated by cluster analysis. Samples could be separated into two groups/clusters with similar molecular mass, chlorination degree and congener pattern. With the exception of one sample, the use of CH4-ECNI-MS led to an overestimation of the chlorine content. Moreover, the influence of different SCCP mixtures on the quantification was studied. The results showed that small differences in the chlorine content could sometimes cause substantial systematic errors of up to 119% despite similar homologue and congener patterns. Errors of quantification corresponded to the deviations between response factors of sample and standard. As a consequence SCCPs should be quantified with a standard matching the overall response factor of the sample.  相似文献   

13.
Exposure to volatile organic chemicals (VOCs) in drinking water has been linked to a number of adverse health effects including cancer, liver, and kidney damage. However, the large number of potential contaminants and the cost and complexity of existing analytical methods limits the extent to which water quality is routinely characterized. This project focused on the laboratory development and evaluation of an instrument for field analysis of VOCs in drinking water. The instrument is based on an array of six polymer-coated surface-acoustic-wave microsensors. A test-set consisting of dichloromethane, chloroform, 1,1,1-trichloroethane, perchloroethylene, and m-xylene was used in a series of experiments designed to optimize the purge-trap preconcentration system, calibrate the instrument over the concentration range of 0.2-2 times the USEPA maximum contaminant levels (MCLs), and compare results to those of a reference laboratory. The primary goal was to develop a cost-effective alternative for on-site evaluation of VOCs in water. Calibration and evaluation test results for spiked water samples demonstrate adequate sensitivity for 19 of the 21 regulated VOCs considered using a ten minute sampling and analysis cycle. Monte Carlo simulations characterized the performance of trained artificial neural networks (ANNs) which had correct classification rates of 99%, 90%, and 80% for the five individual test-set vapors and their binary and ternary mixtures, respectively. These results demonstrate the excellent potential of this technology for addressing the need for improved VOC field-screening methods for water supplies.  相似文献   

14.
Low flow active sampling techniques collecting vapors and gases using thermally desorbable adsorbents are now feasible and desirable in many applications as they permit long integration times, the potential for miniaturized sampling configurations, and other advantages. At very low air flow rates (< 1 ml min(-1)), diffusive uptake on adsorbents in conventional sorbent tubes may equal or exceed the active (pumped) uptake rate, and even at low flow rates (1-4 ml min(-1)), diffusive uptake may significantly bias measurements. Thus, corrections to account for the diffusive flux or means to limit the diffusive uptake are needed in low flow applications. This paper presents (1) a theoretical analysis of the role of diffusive and advective uptake for several sampling geometries of tube-type samplers; (2) experimental confirmation using both laboratory and field studies; (3) estimates of the tortuosity and porosity of the glass wool packing used to retain the adsorbent, parameters needed to estimate diffusive fluxes in passive and active sampling; (4) a demonstration that orifice-equipped low flow active samplers can reduce diffusive uptake and improve precision, and (5) a model predicting the saturated adsorbent layer that helps to account for the gradual decline in uptake rates seen in passive sampling. Diffusive uptake will depend on the tube configuration and diffusion coefficient of the substance of interest, but for conventional sampling tubes (0.4-0.5 cm id, 1.5 cm air gap), sample flow rates should be maintained above 1 to 4 ml min(-1) to keep errors below 5%. Laboratory experiments showed close agreement with theoretical calculations, and the field study using 1 to 4 d sampling periods and 0.3 ml min(-1) flows demonstrated that the orifice-equipped samplers essentially eliminated diffusive uptake. No significant practical difficulties are encountered using orifices, e.g., pressure drop is minimal. Experimental estimates of tortuosity (0.79 +/- 0.02) and porosity (0.92 +/- 0.10) of the glass wool packing (0.3 cm length) represent relatively little resistance to diffusion; however, variation in the packing and adsorbent placement can degrade the precision achievable by passive samplers. Diffusion barriers, consisting most simply of an orifice, may be used to lower the diffusive uptake. A needle-type orifice permits flows below 0.1 ml min(-1) and is suitable for sampling periods as long as several weeks, and it provided greater precision than conventional open-ended sampling tubes (8% compared to 13%). Finally, the gradual decrease in diffusive fluxes often seen in passive sampling is attributed to additional resistance posed by a saturated adsorbent layer, in agreement with a simple model based on total VOCs and specific adsorptivity of the adsorbent.  相似文献   

15.
The low degradation rate of two-phase olive mill wastes (TPOMW) during composting and after soil application is a characteristic feature of these materials. The aim of this work was to evaluate the relationship between the lignocellulosic fraction of TPOMW and the organic matter (OM) degradation rate in three agricultural soils amended with four TPOMW composting mixtures at different degree of stabilisation and prepared with different bulking agents and N sources. The mineralisation kinetics of TPOMW composting mixtures in soil reflected a large amount of slowly mineralisable C even in the starting mixtures (I and T1) where this fraction represented up to 85% of the total potentially mineralisable C pool. The effect of rich lignocellulosic composition was confirmed by the study of the DTS (50% dry TPOMW + 50% sheep manure) mixtures prepared with dry TPOMW, which had undergone partial degradation in a storage pond for one year before composting. These DTS samples showed a more similar kinetic behaviour in soil than the more transformed composting mixtures as reflected in the principal component analysis (PCA) diagram, where they were grouped in the same quadrant dominated by the lignin/holocellulose ratio. Soils amended with mature composts evolved very low amounts of C (between 2 and 6% of the added C) after two months of incubation, which highlights the suitability of these materials as a suitable C source for the soil to promote long term soil C stabilisation.  相似文献   

16.
采用固体进样原子吸收法直接测定土壤中的镉,可以避免传统酸消解预处理过程耗时长、试剂消耗大、操作步骤繁琐等缺点,提升镉的检测效率。通过优化测镉仪的仪器参数,确定了固体进样-电热蒸发-原子吸收法的优化仪器条件。采用优化条件测定了不同浓度的土壤样品,研究了该方法的检出限、正确度、精密度。研究结果表明:镉质量范围为0~200 ng时与峰面积的线性相关系数优于0.999 5,空气流下优化的灰化温度和热解温度均为800 ℃,优化的热解气体氢气流量为300 mL/min,当样品进样量为0.1 g时,检出限为0.009 mg/kg,7次连续测定相对标准偏差为1.4%~5.0%,加标回收率为96.2%~102.1%,分析时间小于4 min。该方法操作简便,用时短,无需高压气源,可以用于土壤中镉的高效检测。  相似文献   

17.
A new analytical technique based on DRIFTS spectroscopy has been developed for the specific and sensitive determination of size-fractionated wood dust from 37 mm glass fiber filter samples collected with the Respicon sampler. A translational diffuse reflectance apparatus was modified to accept filter samples by incorporating a special filter holder in the sample stage and a clockwork motor to drive the translational stage during infrared scanning, thus providing an average analysis across the filter face. Filter samples were pre-treated with ethyl acetate to uniformly redeposit dust onto the filter and extract potential chemical interferences. Two absorbance maxima (1251 and 1291 cm(-1)), corresponding to the cellulose content of the wood, were suitable for quantitation of wood dust. Analysis of seven species of wood at 1291 cm(-1) showed an equivalent quantitative response for all species except maple. The response at 1251 cm(-1) was more variable across species but more sensitive for the softwoods. There was a statistically significant effect of particle size on the analytical response, so that analytical standards should be matched to the samples in terms of particle size distribution. Analytical limit of detection was approximately 0.08 mg of wood dust per sample with overall precision of about 6%. Comparison of DRIFTS and gravimetric analyses of 51 pure wood dust samples ranging from about 0.2 to 2 mg yielded a slope of 1.08 and r2 equal to 0.9. Other particulate contaminants common in the industrial wood processing industry showed little or no interference with the determination of wood dust by this method.  相似文献   

18.
An investigation of contemporary exposure to formaldehyde and organic solvents has been carried out during surface coating with acid-curing lacquers and paints in the Norwegian woodworking and furniture industry over a period of 3 years. The investigation covered 27 factories of different sizes and with different types of production, and totally 557 parallel formaldehyde and solvent samples were collected. The formaldehyde concentration (geometric mean) was 0.15 ppm (range 0.01-1.48 ppm) with about 10% of the samples exceeding the Norwegian occupational exposure limit of 0.5 ppm. The solvent concentration as additive effect (geometric mean) was 0.13 (range 0.0004-5.08) and about 5% of the samples exceeded the Norwegian occupational exposure limit. The most frequently occurring solvents from acid-curing lacquers were n-butyl acetate, ethanol, ethyl acetate and 1-butanol, which were found in 88-98% of the samples. Toluene, n-butyl acetate and 1-butanol were the only solvents with maximum concentrations exceeding their respective occupational exposure limits. Curtain painting machine operators were exposed to the highest concentrations of both formaldehyde (geometric mean 0.51 ppm, range 0.08-1.48 ppm) and organic solvents (additive effect, geometric mean 1.18, range 0.02-5.08). Other painting application work tasks such as automatic and manual spray-painting, manual painting and dip painting, showed on average considerably lower concentrations of both formaldehyde (geometric means 0.07-0.16 ppm) and organic solvents (additive effect, geometric mean 0.02-0.18). Non-painting work tasks also displayed moderate concentrations of formaldehyde (geometric means 0.11-0.17 ppm) and organic solvents (additive effect, geometric mean 0.04-0.07).  相似文献   

19.
The inductively coupled plasma-mass spectrometry (ICP-MS)-determined 206Pb/207Pb ratio of 145 samples of rainwater collected at 25 locations around Scotland during December 1997 and January 1998 and at three longterm monitoring stations in the northeast, central belt and southeast of the country from November 1997 to December 1998 averaged 1.144+/-0.017 (1 s). This represents a significant increase from the mean value of 1.120+/-0.016 recorded for the long-term sites in 1989 1991, only partly attributable to a concomitant increase in the 206Pb/207Pb ratio of leaded petrol from 1.075+/-0.013 to 1.088+/-0.007. The rainwater 206Pb/207Pb data for the late 1990s also contrast markedly with the lower 206Pb/207Pb ratios found for pine needle and atmospheric particulate samples from Scotland (e.g. Glasgow: 1.085+/-0.012 in 1985-1986, 1.099+/-0.007 in 1991-1992), England and Western Europe in this study for the period 1982-1992 when emissions of lead to the atmosphere from petrol-engined vehicles in the UK were approximately 2-9 times higher. The observed change in the lead isotopic signature of rainwater predominantly reflects the impact of measures, such as the introduction and growing uptake of unleaded petrol, to reduce car exhaust emissions of lead to the atmosphere in the UK. Based on the rainwater data, source apportionment calculations suggest a general decline in the contribution of leaded petrol to atmospheric lead in Scotland from 53-61% in 1989-1991 to 32-45% in 1997-1998, with a corresponding decline in the urban environment from 84-86% to 48-58%.  相似文献   

20.
Air sampling, using sorbents, thermal desorption and gas chromatography, is a versatile method for identifying and quantifying trace levels of volatile organic compounds (VOCs). Thermal desorption can provide high sensitivity, appropropriate choices of sorbents and method parameters can accommodate a wide range of compounds and high humidity, and automated short-path systems can minimize artifacts, losses and carry-over effects. This study evaluates the performance of a short-path thermal desorption method for 77 VOCs using laboratory and field tests and a dual sorbent system (Tenax GR, Carbosieve SIII). Laboratory tests showed that the method requirements for ambient air sampling were easily achieved for most compounds, e.g., using the average and standard deviation across target compounds, blank emissions were < or = 0.3 ng per sorbent tube for all target compounds except benzene, toluene and phenol; the method detection limit was 0.05 +/- 0.08 ppb, reproducibility was 12 +/- 6%, linearity, as the relative standard deviation of relative response factors, was 16 +/- 9%, desorption efficiency was 99 +/- 28%, samples stored for 1-6 weeks had recoveries of 87 +/- 9%, and high humidity samples had recoveries of 102 +/- 12%. Due to sorbent, column and detector characteristics, performance was somewhat poorer for phenol groups, ketones, and nitrogen containing compounds. The laboratory results were confirmed in an analysis of replicate samples collected in two field studies that sampled ambient air along roadways and indoor air in a large office building. Replicates collected under field conditions demonstrated good agreement except for very low concentrations or large (> 41 volume) samples of high humidity air. Overall, the method provides excellent performance and satisfactory throughput for many applications.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号