首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Leclerc D  Duo WL  Vessey M 《Chemosphere》2006,63(4):676-689
This paper discusses the effects of combustion conditions on PCDD/PCDF emissions from pulp and paper power boilers burning salt-laden wood waste. We found no correlation between PCDD/PCDF emissions and carbon monoxide emissions. A good correlation was, however, observed between PCDD/PCDF emissions and the concentration of stack polynuclear aromatic hydrocarbons (PAHs) in the absence of TDF addition. Thus, poor combustion conditions responsible for the formation of products of incomplete combustion (PICs), such as PAHs and PCDD/PCDF precursors, increase PCDD/PCDF emissions. PAH concentrations increased with higher boiler load and/or low oxygen concentrations at the boiler exit, probably because of lower available residence times and insufficient excess air. Our findings are consistent with the current understanding that high ash carbon content generally favours heterogeneous reactions leading to either de novo synthesis of PCDD/PCDFs or their direct formation from precursors. We also found that, in grate-fired boilers, a linear increase in the grate/lower furnace temperature produces an exponential decrease in PCDD/PCDF emissions. Although the extent of this effect appears to be mill-specific, particularly at low temperatures, the results indicate that increasing the combustion temperature may decrease PCDD/PCDF emissions. It must be noted, however, that there are other variables, such as elevated ESP and stack temperatures, a high hog salt content, the presence of large amounts of PICs and a high Cl/S ratio, which contribute to higher PCDD/PCDFs emissions. Therefore, higher combustion temperatures, by themselves, will not necessarily result in low PCDD/PCDFs emissions.  相似文献   

2.
Hazardous wastes in the environment represent one of our most serious problems. Ever increasing quantities of toxic wastes have contaminated our land, air, and water. Lack of adequate hazardous waste disposal facilities is a critical problem. Landfilling toxic wastes is no longer considered safe. The tragedy of the Love Canal has demonstrated the need for proper hazardous waste disposal facilities. The best organic chemical waste disposal method is process incineration. Cement kilns have been used for burning toxic chemical industrial wastes in Canada, Michigan, New York, Sweden, etc. Existing cement kilns, when properly operated, can destroy most organic chemical wastes. Even the most complex chlorinated hydrocarbons, including PCB can be completely destroyed during normal cement kiln operations, with minimal emissions to the environment. Burning toxic chemical wastes in cement kilns, and other mineral industries, is mutually beneficial to both industry, who generates such wastes, and to society and government, who want to dispose properly of such wastes in a safe, environmentally acceptable manner. The added benefit of energy conservation is important, since large quantities of valuable fuel can be saved in the manufacture of cement when such techniques are employed.  相似文献   

3.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

4.
PCDD/PCDF reduction by the co-combustion process   总被引:1,自引:0,他引:1  
Lee VK  Cheung WH  McKay G 《Chemosphere》2008,70(4):682-688
A novel process, termed the co-combustion process, has been developed and designed to utilise the thermal treatment of municipal solid waste (MSW) in cement clinker production and reduce PCDD/PCDF emissions. To test the conceptual design; detailed engineering design of the process and equipment was performed and a pilot plant was constructed to treat up to 40 tonnes MSW per day. The novel process features included several units external to the main traditional cement rotary kiln: an external calcinations unit in which the hot gas calcined the limestone thus making significant energy savings for this chemical reaction; the lime generated was used in a second chamber to act as a giant acid gas scrubber to remove SOx and particularly HCl (a source of chloride); an external rotary kiln and secondary combustion unit capable of producing a hot gas at 1200 degrees C; a gas cooler to simulate a boiler turbogenerator set for electricity generation; the incorporation of some of the bottom ash, calcined lime and dust collector solids into the cement clinker. A PCDD/PCDF inventory has been completed for the entire process and measured PCDD/PCDF emissions were 0.001 ng I-TEQ/Nm(3) on average which is 1% of the best practical means [Hong Kong Environmental Protection Department, 2001. A guidance note on the best practicable means for incinerators (municipal waste incineration), BPM12/1] MSW incineration emission limit values.  相似文献   

5.
Abstract

This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 °C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 μg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 μg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

6.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

7.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

8.
In this study, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) in breast milk from mothers living in the vicinity of a new hazardous waste incinerator (HWI) were determined. Monitoring was performed after three years of regular operations in the facility and the present results were compared with baseline concentrations obtained in a pre-operational program. PCDD/PCDF levels were determined by HRGC/HRMS in 15 samples. In the present study, PCDD/PCDF concentrations ranged from 4.9 to 39.9 pg I-TEQ/g fat (5.1-46.8 pg WHO-TEQ/g fat), with a median value of 7.7 pg I-TEQ/g fat (9.1 pg WHO-TEQ/g fat). In the baseline survey, PCDD/PCDF concentrations ranged between 5.9 and 17.1 pg I-TEQ/g fat, with a median value of 11.7 pg I-TEQ/g fat. In relation to this, a percentage of reduction of 34.2% was noted. This decrease is in agreement with the relevant reduction found in the dietary intake of PCDD/PCDFs between both surveys. The results of the present study, as well as other recent environmental and biological data, indicate that living in the vicinity of this HWI should not mean additional health risks due to PCDD/PCDFs for the general population.  相似文献   

9.
In laboratory-scale combustion of polyvinylidene chloride (PVDC) with a quartz tubular furnace designed and fabricated to provide the desired combustion temperature and mixing state of combustion gas with air, it was found that at 800 degrees C or higher the level of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans [corrected] (PCDDs/PCDFs) resulting from PVDC combustion was no higher than that from heating air alone, and thus far below the levels which resulted from PVDC combustion at 750 degrees C or lower. The results provide the first laboratory confirmation of the relation between PVDC incineration temperature and PCDD/PCDF formation, and of the primary importance of high temperature, turbulence for mixing between air and combustion gas, and sufficient residence time, as governing factors for the minimization of PCDD/PCDF formation in municipal solid waste incinerators.  相似文献   

10.
The production of cement in China is accompanied by various emissions, such as fine particulate matter, heavy metals, nitrogen oxides, sulfur oxides, carbon dioxide…. Moreover, cement kiln presents a potential health risk to its surroundings, linking to emissions of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in brief dioxins. Flue gas samples were collected from five typical cement kilns during twelve runs and were used to evaluate the levels and distribution of PCDD/Fs in the emissions from cement kilns. The PCDD/Fs concentrations (136 congeners) and I-TEQ values ranged from 2.3 to >40 ng/m3 and 9.3?~?90.8?×?10?3 ng I-TEQ/m3, respectively, which were lower than the emission standard in China (0.1 ng I-TEQ/m3). In weight units, the dominant congeners were OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF; 2,3,4,7,8-PeCDF is the largest contributor (36–66 %) to the total I-TEQ value of twelve runs. HxCDF and TCDF were the first two most abundant homologue groups (12–85 and 4–52 %), and the homologue concentration decreased with rising chlorine number for PCDDs. In addition, there was no marked difference in homologue profiles when solid wastes (refuse-derived fuel and municipal solid waste) and hazardous wastes (DDT and POPs) were combusted as supplemental fuels. The use of various supplemental fuels had no obvious effect on the fingerprint of PCDD/F homologues. Moreover, there was no significant difference in levels of PCDD/Fs emission due to the diversity of production capacity, which were consistent with reported previously. Air pollution control device had effect on the homologue profiles, and cement system with electrostatic precipitators (ESP) had more fractions of octachloro congeners to the total.  相似文献   

11.
Experimental data on PCDD and PCDF emissions in raw gases from municipal solid waste combustion in a pilot plant were processed by Response Surface models to gain information on process parameter values which minimize both the total PCDD/PCDF concentrations and those of a selected congener group.  相似文献   

12.
In 2007, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) were determined in plasma of non-occupationally exposed subjects living near the only hazardous waste incinerator (HWI) in Spain (Constantí, Tarragona County, Catalonia). These data were compared with the levels found in two previous surveys performed in 1998 (baseline) and 2002. The current mean PCDD/PCDF concentration in plasma was 9.36pg I-TEQg(-1) of lipid (range: 1.76-23.44pg I-TEQg(-1) of lipid). It means a significant reduction of the mean PCDD/PCDFs levels in plasma in comparison to the concentrations found in 1998 and 2002 (27.01 and 15.70pg I-TEQg(-1) of lipid, respectively). This important decrease agrees well with the notable reduction in the dietary intake of PCDD/PCDFs recently noted for the population of the same area (210.1pg I-TEQd(-1), 63.8pgWHO-TEQd(-1), and 27.8pgWHO-TEQd(-1), in 1998, 2002 and 2007, respectively). The current data were also used to predict theoretical PCDD/PCDF concentrations in plasma by executing a single-compartment empirically-based pharmacokinetic model on the basis of the daily intake of these pollutants by the local population.  相似文献   

13.
Ogura I  Masunaga S  Nakanishi J 《Chemosphere》2001,44(6):1473-1487
The atmospheric bulk (dry and wet) deposition of dioxins was investigated at four locations (Tokyo, Yokohama, Tsukuba, and Tanzawa) in the Kanto region (in Japan) over one year using a stainless-steel pot. Annual average polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans (PCDD/PCDF) deposition fluxes were estimated to be from 450 to 1300 ng/m2/yr, and the annual average TEQ fluxes from 5.7 to 17 ng-TEQ/m2/yr at the four locations. The PCDD/PCDF deposition flux was higher in winter than in summer. The deposition flux could be related to ambient temperature, particularly for less chlorinated PCDDs/PCDFs, while the deposition flux is not necessarily related to the amount of precipitation. The PCDD/PCDF deposition flux increased as the particle deposition flux increased, for the winter samples. Based on the ratio of the PCDD/PCDF deposition fluxes to the particle deposition fluxes, the contribution of the reentrainment of soil particles to the TEQ of PCDD/PCDF deposition was considered to be negligible in this region. Based on the air concentrations monitored near our deposition sampling points by the municipalities, the ratio of the annual deposition flux to the annual average air concentration was roughly estimated to be 0.082 cm/s. The range of deposition flux in the Kanto region was estimated to be from 1.5 to 31 (median: 9.8) ng-TEQ/m2/yr based on the range of air concentration data measured by the municipalities. The total annual deposition flux in the entire Kanto region was estimated to range from 50 to 900 g-TEQ/yr (median 320 g-TEQ/yr). This estimated flux was of the same order as the sum of estimated emissions from municipal solid waste incinerators and industrial waste incinerators in the Kanto region. The contributions of dioxin-like PCBs in Yokohama, Tsukuba, and Tanzawa depositions were less than 10% of the total TEQ; however, in Tokyo it was almost equal to or more than 50%.  相似文献   

14.
In 1997, the Polychlorinated dibenzo-para-dioxin (PCDD)/Polychlorinated dibenzofuran (PCDF) concentrations in dairy products in Germany and other European countries increased. The PCDD/PCDF source was contaminated lime used in Brazilian citrus pulp pellets. The contaminated lime was mined from an industrial dump site. However, the detailed origin of the PCDD/PCDFs in the lime was not revealed. This paper investigates the contamination origin and describes the link between lime milk from the dumpsite of a chlorine/organochlorine industry and the contaminated lime. The contaminated lime stem from mining at the corporate landfill of Solvay Indupa in Sao Paulo. The landfill was used for 40 years for deposition of production residues and closed in 1996. The factory operated/operates at least two processes with potentially high PCDD/PCDFs releases namely the oxychlorination process for production of ethylene dichloride (EDC) and the chlor-alkali process. The main landfilled waste was lime milk (1.4 million tons) from the vinyl chloride monomer production (via the acetylene process) along with residues from other processes. The PCDD/PCDF fingerprint revealed that most samples from the chemical landfill showed an EDC PCDD/PCDF pattern with a characteristic octachlorodibenzofuran dominance. The PCDD/PCDF pattern of a Rio Grande sediment samples downstream the facility showed a chlor-alkali pattern with a minor impact of the EDC pattern. The case highlights that PCDD/PCDF- and persistent organic pollutants-contaminated sites need to be identified in a comprehensive manner as required by the Stockholm Convention (article 6) and controlled for their impact on the environment and human health. Landfill mining and reuse of materials from contaminated deposits should be prohibited.  相似文献   

15.
Alcock RE  Gemmill R  Jones KC 《Chemosphere》1999,38(4):759-770
PCDD/F data are presented from 75 samples of primary emissions sampled between 1995-97 as part of the compliance monitoring survey undertaken by the UK Environment Agency. Municipal solid waste (MSW), chemical waste and clinical waste incinerators, cement kilns, sinter plants and sewage sludge incinerators were the source categories monitored and reported here. Based on this monitoring programme, the previous national UK emission estimates by Eduljee and Dyke (1) of 560-1100 g I-TEQ a(-1) for 1993 have been revised downwards to 220-660 g I-TEQ a(-1). Despite source reduction measures, MSW incinerators remain a significant source of PCDD/Fs to the atmosphere, contributing between 30-50% of the EPCDD/F I-TEQ emission, rather than the approximately 80% they were estimated to contribute in 1993. 2,3,7,8-substituted PCDD/F congener profile data are presented for some of the source categories and generally support the view that differences in the mixtures ('fingerprints') of PCDD/Fs emitted from different sources are observed. New data on the dioxin-like PCB emissions are presented for cement kilns and sinter plants. These show that TEQ-rated PCBs can make an important contribution to the I-TEQ emitted from certain combustion sources. High concentrations of a full range of PCB congeners/homologues have been measured in the atmosphere close to sintering strands, although the precise source of PCBs from this process remains unclear.  相似文献   

16.
Weber R  Sakurai T  Ueno S  Nishino J 《Chemosphere》2002,49(2):127-134
The correlation of PCDD/PCDF levels with the CO emissions in a full-scale municipal waste incinerator was assessed during a four-week measurement effort. PCDD/PCDF concentrations in fly ashes-containing more than 99% of the total PCDD/PCDF burden of the fluidized bed incinerator (FBI)-were measured and compared with the emitted CO concentrations. The CO concentration during the sampling time showed no significant correlation to the PCDD/ PCDF amount in fly ash (R2 = 0.078). However, a comparison of the time integrated CO concentration several hours before sampling lead to a correlation with the PCDD/PCDF burden. Maximum correlation was found for the time integrated CO values of 3 and 4 h before sampling (R2 = 0.467 and R2 = 0.457 respectively). This indicates a memory effect in the high temperature cooling section of several hours. Possible mechanisms leading to the memory effect are discussed. The correlation of PCDD/PCDF with CO concentration demonstrate that the combustion conditions play an important role for PCDD/PCDF formation in FBIs. However the variability in the correlation of CO to PCDD/PCDF levels show that other factors have a significant influence on PCDD/PCDF formation.  相似文献   

17.
Nine typical waste incinerating plants were investigated for polychlorinated naphthalene (PCN) contents in their stack gas. The incinerators investigated include those used to incinerate municipal solid, aviation, medical, and hazardous wastes including those encountered in cement kilns. PCNs were qualified and quantified by isotope dilution high resolution gas chromatography–high resolution mass spectrometry techniques. An unexpectedly high concentration of PCNs (13,000 ng?Nm?3) was found in the stack gas emitted from one waste incinerator. The PCN concentrations ranged from 97.6 to 874 ng?Nm?3 in the other waste incinerators. The PCN profiles were dominated by lower chlorinated homologues, with mono- to tetra-CNs being the main homologues present. Furthermore, the relationships between PCNs and other unintentional persistent organic pollutants involving polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated biphenyls, hexachlorobenzene, and pentachlorobenzene were examined to ascertain the closeness or otherwise of their formation mechanisms. A good correlation was observed between ΣPCN (tetra- to octa-CN) and ΣPCDF (tetra- to octa-CDF) concentrations suggesting that a close relationship may exist between their formation mechanisms. The results would provide an improved understanding of PCN emissions from waste incinerators.  相似文献   

18.
Steps towards a European dioxin emission inventory   总被引:7,自引:0,他引:7  
Quass U  Fermann MW  Bröker G 《Chemosphere》2000,40(9-11):1125-1129
The results of a project aiming at collection and evaluation of information regarding the industrial and non-industrial emission sources for dioxins and furans (PCDD/PCDF) in 17 European Countries (EU 15, CH, N) are presented. An overview about national documents covering dioxin emission inventories for the period 1990-1995 is given. Some data on emissions associated with residual materials, waste and waste water are presented additionally. Based on the air emission data contained in these documents the most important emission sources were determined which are assumed to cover about 90% of the overall emissions. For the selected sources and for all 17 countries new estimates of the atmospheric PCDD/PCDF emissions were derived from average emission factors and statistical activity rates for the year 1994. As a result, on the European scale the largest annual PCDD/PCDF emission is assessed to be released from municipal waste incineration, quite closely followed by emissions from iron ore sintering. Considerable releases of dioxins and furans--based, however, on highly uncertain data--are further assessed for domestic burning, accidental fires and (former) use of contaminated wood preservatives (pentachlorophenol). A lower but still significant emission is further assigned to the sector of non-ferrous metal production; particular processes used in this branch proved to generate very high PCDD/PCDF flue gas concentrations.  相似文献   

19.
Weber R 《Chemosphere》2007,67(9):S109-S117
One important criterion for assessment of a POPs destruction technology is the potential formation of new POPs and other toxic by-products, in particular whether the highly toxic PCDDs/PCDFs are formed and under which operation conditions their formation is relevant. For incineration processes the formation mechanisms of PCDDs/PCDFs have been investigated thoroughly and strategies and technologies were developed to minimize their formation and emission. A detailed assessment of non-combustion technologies with respect to PCDD/PCDF formation is, however, lacking to date. A comparison of reaction conditions for PCDD/PCDF formation from precursor formation studies and actual applied conditions of a broad range of POPs destruction technologies in the present paper indicates that the operation conditions for a number of destruction technologies have the potential to generate high concentrations of PCDDs/PCDFs if dioxin precursors are present and that also PCDD/PCDF de novo formation can take place. Therefore a strategy and regulations for a more profound assessment and monitoring of the fate of PCDD/PCDF formation and emission is essential for the evaluation of POP destruction technologies and for a sound risk management of POPs. The present paper aims to provide a critical impulse in this respect, discusses the relevant formation pathways with respect to POPs destruction technologies and proposes a basic framework on how evaluations may be performed.  相似文献   

20.
Martí-Cid R  Bocio A  Domingo JL 《Chemosphere》2008,70(9):1588-1595
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were measured in foodstuffs randomly acquired in July 2006 in various locations of Tarragona County (Catalonia, Spain), which are near a hazardous waste incinerator (HWI). A total of 35 composite samples, belonging to various food groups (vegetables, pulses, cereals, fruits, fish and seafood, meat and meat products, eggs, milk, dairy products, and oils and fats) were analyzed by HRGC/HRMS. The dietary intake of PCDD/PCDFs was subsequently determined and compared with a previous survey performed in 2002. For calculations, recent data on consumption of the selected food items were used. Total dietary intake of PCDD/PCDFs for the general population of Tarragona County was estimated to be 27.81 pg WHO-TEQ/day, value notably lower than that found in the 2002 study, 63.80 pg WHO-TEQ/day. Fish and seafood (28%), oils and fats (22%), eggs (17%), and dairy products (11%) were the most important contributors to this intake, while pulses (1%), milk (2%), vegetables (3%) and fruits (3%) showed the lowest contribution to total WHO-TEQ. The current PCDD/PCDF intake is also considerably lower than the intake estimated in 1998 for the population of the same geographical area, 210.1 pg I-TEQ/day, when a baseline study was carried out during the construction of the HWI. The present intake is also compared with the dietary intakes of PCDD/PCDFs recently (2006-2007) reported for a number of regions and countries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号