首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Ferrario J  Byrne C 《Chemosphere》2002,46(9-10):1297-1301
Processed ball clay samples used in the production of ceramics and samples of the ceramic products were collected and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and -furans (PCDDs/PCDFs). The processed ball clay had average PCDD concentrations of 3.2 ng/g toxic equivalents, a congener profile, and isomer distribution consistent with those found previously in raw ball clay. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. The final fired ceramic products were found to be free of PCDDs/PCDFs at the LODs. A consideration of the conditions involved in the firing process suggests that the PCDDs, if not destroyed, may be released to the atmosphere and could represent an as yet unidentified source of dioxins to the environment. In addition, the PCDDs in clay dust generated during manufacturing operations may represent a potential occupational exposure.  相似文献   

2.
Ferrario J  Byrne C  Schaum J 《Chemosphere》2007,67(9):1816-1821
Processed ball clays commonly used by the ceramic art industry in the United States were collected from retail suppliers and analyzed for the presence and concentration of the 2,3,7,8-Cl substituted polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs). The average PCDD toxic equivalent (TEQ) concentrations of these processed ball clays was approximately 800 pg/g (TEQ-WHO) with characteristic congener profiles and isomer distributions similar to patterns of previously analyzed raw and processed ball clays. The PCDF concentrations were below the average limit of detection (LOD) of 0.5 pg/g. Correlation analyses reveal no significant relationship between total organic carbon (TOC) and either individual, homologues, and total tetra-through octa-chlorinated PCDD congeners, or TEQ concentrations of the processed ball clays. The results are consistent with earlier studies on levels of PCDDs in ball clays. Data from earlier studies indicated that dioxins may be released to the environment during the processing of raw clay or the firing process used in commercial ceramic facilities. The presence of dioxin in the clays also raises concerns about potential occupational exposure for individuals involved in the mining/processing of ball clay, ceramics manufacturing and ceramic artwork.  相似文献   

3.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

4.
Breast milk is known to discharge dioxins from the human body. However, to date, no direct comparison has been made of the concentrations of dioxin analogues in breast milk obtained from identical population after successive deliveries. We present here follow-up survey results of PCDDs, PCDFs, and dioxin-like PCBs concentrations in human breast milk samples from 35 women living in Tokyo from whom samples had been obtained and analyzed to determine the corresponding concentrations in the past. The average concentrations of total PCDDs, PCDFs, dioxin-like PCBs were 8.5, 5.5, 11 TEQ pg/g fat for the first samples and 5.4, 4.0, 6.6 TEQ pg/g fat for the second samples, respectively. The degrees of reduction of total PCDDs and total dioxin-like PCBs were higher than that of total PCDFs because 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF and 3,3',4,4',5-PeCB (#126), which were the predominant congeners among PCDDs, PCDFs, and dioxin-like PCBs, respectively, had different degrees of reduction. Moreover we observed a significant increase of the concentrations of PCDDs, PCDFs, and dioxin-like PCBs in samples from three women in this follow-up survey, and the patterns of increased isomers differed among the three samples. It was conjectured that the increase of the concentrations was due mainly to dietary intake between deliveries. It is important for pregnant women to have a balanced diet to mitigate the exposure of infants to these chemicals.  相似文献   

5.
Chovancová J  Kocan A  Jursa S 《Chemosphere》2005,61(9):1305-1311
The levels of 17 toxic polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and 12 non-ortho and mono-ortho polychlorinated biphenyls (PCBs) in 73 foodstuff samples of animal origin collected from shops and small farms in selected districts of Slovak Republic are presented in this paper. The concentrations expressed as WHO-TEQ in analysed samples ranged for PCDDs/PCDFs from 0.25 pg/g fat in pork to 75 pg/g fat in cod liver. The TEQ concentrations of non-ortho PCBs were between 0.007 and 181 pg/g fat and mono-ortho PCBs between 0.0083 and 66.5 pg/g fat. The mean concentrations in freshwater fish and imported species of marine fish were 0.089 pg TEQ/g fresh weight for PCDDs/PCDFs, 0.17 pg TEQ/g fresh weight for non-ortho PCBs and 0.034 pg TEQ/g fresh weight for mono-ortho PCBs. The mean total concentration of PCDDs/PCDFs and dioxin-like PCBs in samples of infant milk formula imported from EU countries was 0.98 pg TEQ/g fat.  相似文献   

6.
DESIGN: Human milk samples were collected and analysed for the levels of polychlorinated dibenzodioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and selected dioxin-like polychlorinated biphenyls (PCBs). In total, 157 individual samples collected during 2002 and 2003 as well as 24 samples collected in 1993 were analysed as 20 pools. RESULTS: PCDDs, PCDFs and dioxin-like PCBs were detected in all pooled samples. For samples collected during 2002/2003, the TEQ(DFP) ranged from 6.0 to 15.2 pg TEQ g(-1) lipid with an average of 9.0 pg TEQ g(-1) lipid. The average lipid content was 3.7+/-0.5%. No systematic differences were observed in the levels of PCDDs, PCDFs and PCBs in human milk samples collected from different regions of Australia during 2002/2003. For samples collected in 1993 and analysed as pools, the mean level, expressed as TEQ(DFP) was 16+/-1.4 pg TEQ g(-1) lipid. The average lipid content was 3.9+/-0.7%. CONCLUSION: The levels of PCDDs, PCDFs and dioxin-like PCBs in the human milk of Australian women are both low compared to international levels and similar across all regions of Australia. Consistent with world-wide trends, the levels of PCDDs, PCDFs and dioxin-like PCBs have decreased over a 10 year period from 1993 to 2003 by approximately 40%.  相似文献   

7.
Impact of FEBRA (fermented brown rice with Aspergillus oryzae, a rich dietary fiber) intake on the concentrations of polychlorinated-biphenyls (PCBs), -dioxin-like polychlorinated biphenyls (DLPCBs), -dibenzo-p-dioxins (PCDDs), and -dibenzofurans (PCDFs) in blood of nine married Japanese were studied for 2 years. Concentrations of total PCBs (average+/-standard deviation) were greater 326,000+/-263,000 and 207,000+/-89,000 in FEBRA-intake and non-FEBRA-intake groups, respectively, on pg/g lipid (from now onwards data expressed on pg/g lipid). DLPCBs were second major contaminants 94,000+/-77,000 and 60,000+/-28,000, orderly in FEBRA-intake and non-FEBRA-intake groups. The concentrations of PCDD/DFs were several orders of magnitude lower than those of PCBs, whereas PCDDs were greater (433+/-233 and 512+/-511, in FEBRA-intake and non-FEBRA-intake groups, respectively) than PCDFs (56+/-50 and 43+/-35). Calculated toxic equivalency (TEQ) concentrations were 34+/-24 and 23+/-10 in FEBRA-intake and non-FEBRA-intake groups, respectively. In order to corroborate the impact of FEBRA, the changes of PCDD/DFs and PCB concentrations for 0.5-year, 1-year, 1.5-year, and 2-year samples were estimated from average concentration of 1-day before study commences and 1-week study samples. The results explicit FEBRA-intake group eliminated 7%, 33%, 45%, 36%, and 26% and non-FEBRA-intake group eliminated 8%, 28%, 36%, 31%, and 20% of DLPCBs, PCDDs, PCDFs, PCDD/DF TEQ and total TEQ, respectively. This study is the first of its kind showing the possible elimination of PCDDs, PCDFs and their TEQ in humans from Japan after the consumption of FEBRA.  相似文献   

8.
Yang J  Shin D  Park S  Chang Y  Kim D  Ikonomou MG 《Chemosphere》2002,46(3):419-428
We determined breast milk concentration of polychlorinated dibenzo-p-dioxins (PCDDs)/polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in 24 mothers living in Korea, and assessed the maternal body burden based on PCDDs/PCDFs and PCBs concentrations in breast milk and an infant intake rate through breast-feeding based on their concentration in breast milk. PCDDs/PCDFs and PCBs levels in breast milk from primipara mothers were found to be higher than those from multipara mothers. For total PCDDs/PCDFs TEQ level, 2,3,4,7,8-PeCDD was the predominant congener, and the proportion of 2,3,7,8-TCDD was less than 3% of total PCDDs/PCDFs TEQ level. For PCBs TEQ level, PCB-126 was the predominant congener. Maternal body burden levels of PCDDs/PCDFs and PCBs based on their concentrations in breast milk were 268-622 TEQ ng. The daily dioxin intakes of mothers were predicted to be 0.78-2.18 TEQ pg/kg/day for PCDDs/PCDFs and 0.34-0.66 TEQ pg/kg/ day for PCBs. For the first year, the body burden of an infant was predicted to be 212 TEQ ng and the daily intake of an infant was predicted to be 85 TEQ pg/kg/day, assuming the mean dioxin-related compounds concentration (27.54 TEQ pg/g fat).  相似文献   

9.
In this paper the results of sampling for trace chlorinated organics at two municipal refuse incinerators in Ontario are presented. The information may be of Interest to individuals concerned with the assessment of PCDD/PCDF (polychlorinated dibenzo-p-dioxin/polychlorinated dibenzofuran) emissions from incineration of refuse and their impact on the energyfrom- waste program. PCDDs, PCDFs, PCBs (polychlorinated biphenyls), CBs (chlorobenzenes) and CPs (chlorophenols) were quantified in all process streams including refuse, ash and stack emissions. Manual sorting of refuse and collection of ash samples were carried out simultaneously with three 24-hour continuous stack sampling tests at each plant. The results suggested that the total output of PCDDs and PCDFs varied proportionately with their input at both incinerators. However, the input of PCDDs/PCDFs could not account for their total output. The chemistry of PCDDs/PCDFs in the input and output streams were different in that only heptachlorinated and octachlorinated species were present in significant quantities in the refuse while lower chlorinated species were predominant in stack emissions and ash streams. There was no correspondence between the Input of PCBs/CBs/CPs and the output of PCDDs/PCDFs. The output of PCDDs/PCDFs, however, varied Inversely with the total output of PCBs/CBs/CPs, suggesting that the latter compounds could have been partially responsible for the formation of PCDDs and PCDFs. The PCDF emissions were also affected by combustion conditions; they were higher in magnitude and consisted of predominantly tetrachlorinated and pentachlorinated species at the plant where the combustion temperatures were lower.  相似文献   

10.
The atmospheric contamination levels of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were evaluated from the analysis of pine needles in South Korea. Pine needles were collected from 30 sampling points at five main cities in South Korea (Busan, Daegu, Gwangju, Changwon and Jeju island). The highest concentrations of PCDDs/DFs (2.19–26.88 pg I-TEQ/g of dry weight) were measured at Busan, where is the city of the highest population density and traffic volume among five cities. The lowest concentration was detected at Jeju with 0.62 pg I-TEQ/g dry weight, suggesting Jeju could be an environmental background area in Korea. The dominant homologues of PCDDs/DFs in pine needles were the lower chlorine-substituted compounds such as tetra CDDs and CDFs, and the distribution ratios of PCDDs/DFs decreased with increase of the number of chlorine substituents. Homologue profiles of pine needle samples were similar to PCDDs/DFs profiles of the vapor phase in the ambient air, and thus the pine needles absorbed the vapor phase of PCDDs/DFs from air. Results suggested that pine needles could be used as an indicator of the atmospheric contamination for PCDDs/DFs in Korea.  相似文献   

11.
Hunt GT  Lihzis MF 《Chemosphere》2011,85(11):1664-1671
The Connecticut Department of Environmental Protection (CTDEP) commenced monitoring for PCDDs/PCDFs (polychlorinated dibenzodioxins and polychlorinated dibenzofurans) in ambient air in 1987 and adopted the long term (30 d) sampling approach in 1993. The CTDEP method represents the first use of isotopically labeled PCDDs/PCDFs as field surrogates to monitor the behavior of native PCDDs/PCDFs present in actual ambient air samples. This feature first introduced in 1987 was later adopted by US EPA in revisions to sampling methods for PCDDs/PCDFs in ambient air (EPA Method TO9A) as well as development of EPA Reference Method 23 for measurement of PCDDs/PCFDs in stationary source emissions. Results are provided here for a total of twenty-three (23) samples (reported as pairs) representing twelve (12) 30 d sampling events conducted at a site located in metropolitan Hartford CT. Samples were collected in winter months during calendar years 2002-2008. PCDDs/PCDFs concentration data (pg m−3) are reported as both congener sums (Cl4-Cl8) and 2378-substitued congeners. Total PCDDs/PCDFs concentrations for these twelve (12) sampling events ranged from 0.68 pg m−3 (2003) to 4.18 pg m−3 (2004) with a mean concentration of 2.04 pg m−3.Method performance was monitored through use of collocated samples, in field isotopically labeled compounds, isotopically labeled laboratory applied internal standards and field blank samples. Method performance consistently exceeded goals established in USEPA Method TO9A for these same parameters. Average recoveries of in field labeled PCDDs/PCDFs ranged from 97.5% to 104.2%. Average (mean) recoveries for each of the ten (10) isotopically labeled internal standards ranged from 77.0% (13C-OCDF) to 95.5% (13C-2,3,7,8-TCDF). Method precision defined as % RPD data for collocated sampler pairs ranged from 8% to 14% for PCDDs and from 5% to 12% for PCDFs. The mean RPD for all PCDDs/PCDFs combined is 9.6%. Field monitoring results demonstrate method sensitivity for all PCDDs/PCDFs congeners and 2378-substituted congeners to be well below concentrations typically found for these compounds in ambient air (all reported data represent measured concentrations). Quantities (pg) found in field blanks represent the major determinant to achieving further enhancements in method sensitivity for selected congeners (OCDD < 42 fg m−3; 1,2,3,4,6,7,8-HpCDD < 5.7 fg m−3; and 1,2,3,4,6,7,8-HpCDF < 2.1 fg m−3). The CTDEP method represents a highly sensitive and reliable technique for monitoring of PCDDs/PCDFs congeners and other persistent organic pollutants (POPs) at ultra trace levels in ambient air (fg m−3).  相似文献   

12.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and non-ortho chlorine substituted coplanar polychlorinated biphenyl (Co-PCBs, non-ortho Cl CBs) in river and offshore sediment samples were analyzed isomer-specifically using (13)C-labeled their respective internal standards and a selected ion monitoring method of high resolution gas chromatograph-mass spectrometry (GC-MS). These compounds were found in all samples analyzed. The average concentrations of the total PCDDs, PCDFs and Co-PCBs in the 23 sediment samples taken from rivers were 11 000, 1300 and 160 pgg(-1) of dry wt, respectively, those in six offshore sediments were 7600, 980 and 52 pgg(-1), respectively. The concentrations of Co-PCBs were much lower than those of PCDDs and PCDFs in all sediment samples. The magnitude of these concentrations was in the order of lower reach of river > offshore area > upper reach of river. The concentrations of PCDDs and PCDFs in the rural river were higher than those in the urban river, whereas the Co-PCB concentration in an urban river was six times higher than that in a rural river. The Co-PCB concentrations in the urban area and industrial area were higher than that in any other area. These findings suggest that the pollution by PCDDs and PCDFs was derived from some kinds of incinerations and herbicides applied in the past and that Co-PCB pollution was caused by PCB preparation used in the past in urban and industrial areas and by municipal waste incineration in urban areas.  相似文献   

13.
Feasibility of three different extraction methods for the simultaneous determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in butter is discussed. The method based on liquid-liquid extraction with water of the non fatty solids from butter dissolved in hexane was found to be the most efficient for the determination of the lipid content and the levels of the investigated pollutants. This method was used to evaluate the background levels of PCBs, PCDDs and PCDFs in butters commercially available in Spain. Broad ranges of PCB, specifically, PCDD and PCDF concentrations were found in the different brands analysed. Levels, profiles and patterns of these pollutants in butter were compared with those previously reported for different Spanish dairy products. The toxic tetra-equivalents of 2,3,7,8-TCDD (1-TEQ) averages for PCDDs and PCDFs in the 21 butter samples analysed were 0.41 and 0.70 pg/g fat basis, respectively. These values were similar or lower than those cited in the literature for other countries.  相似文献   

14.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/DFs), including 2378-substituted isomers were present in samples of shellfish and fish, and ambient air collected from Masan Bay, and Masan City, South Korea. Total concentrations of PCDDs/DFs in mussel and clam were 750 pg g(-1), lipid weight (lw), and 3418 pg g(-1), lw, respectively. Total concentrations of PCDDs/DFs in mullet, gizzard and flounder were 52, 82, and 122 pg g(-1), lw, respectively. Shellfish tissues contained a greater number of PCDD/DF isomers, contributing greater total concentrations of PCDDs/DFs compared to fish collected from the same locations. The predominance of 2378-substituted PCDDs/DFs in fish is represented in greater total concentrations of 2378-TeCDD equivalents (TEQs), whereas there was very limited occurrence of 2378-substituted isomers in shellfish. TEQ concentrations in samples of mussel and clam were 0.97 and 12 pg g(-1), lw, respectively. Total TEQs in mullet, gizzard and flounder were 12, 22 and 18 pg g(-1), lw, respectively. In fish 2378-substituted PCDDs accounted for 100% of the total concentrations of PCDDs, and 2378-substituted PCDFs accounted from 59% to 73% of the total PCDFs. The 2378-substituted isomers accounted for only 3% of the total PCDDs/DFs in shellfish. Ambient air collected from two sites contained a wide range of isomers of tetra- through heptachlorinated PCDDs/DFs. Even though the total concentration of PCDDs/DFs in ambient air (12.8 pgm(-3)) collected from an industrial area was 2-fold greater than that in air samples (6.3 pgm(-3)) collected from an urban/rural area, total TEQs (0.07 and 0.08 pgm(-3)) there was no statistical difference between the two samples.  相似文献   

15.
PCDDs/PCDFs and PCBs in water samples from the Three Gorge Reservoir   总被引:3,自引:0,他引:3  
Chen JA  Luo J  Qiu Z  Xu C  Huang Y  Jin YH  Saito N  Yoshida T  Ozawa K  Cao J  Shu W 《Chemosphere》2008,70(9):1545-1551
The Three Gorge Reservoir (TGR) is the largest reservoir in China and its water quality is an important health concern, we have determined the concentrations of PCDDs/PCDFs and PCBs in the water samples collected at three seasons: August 2004, January 2005 and August 2005. The results showed that the average WHO-TEQ of total dioxins-like compounds (PCDDs/PCDFs+PCBs) was 0.06558 pg l(-1), ranged from 0.0008 to 0.32439 pg l(-1), which are much lower than other reported water sources. The main dioxins (PCDDs/PCDFs) are hepta- and octa-chlorinated dibenzo-p-dioxins (CDDs) and chlorinated dibenzofurans (CDFs). Since the levels of dioxins may change after the last water-store stage, the present study provides important data to compare the water quality in the TGR in the future.  相似文献   

16.
Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) in human have been studied extensively; however, polychlorinated naphthalenes (PCNs) have been studied less widely. The mean concentrations of PCNs, PCDDs, PCDFs, and PCBs in 61 healthy human volunteers were 2170 pg/g lipid, 452 pg/g lipid, 116 pg/g lipid, and 120 ng/g lipid respectively, and the mean toxic equivalents (TEQs) contributed by PCNs, PCDDs, PCDFs, and PCBs were 5.88, 5.22, 5.48, and 5.33 pg/g lipid, respectively. PCNs contributed to 26.8% of the total TEQs. 1,2,3,7,8-PeCDD, 2,3,4,7,8-PeCDF, PCB126, and hepta-CN-73 accounted for >62% of the total TEQs in the human serum samples. The overall serum PCN homologue profiles of all subjects were dominated by tetra- and penta-CN homologues, and the most predominant individual congener was hepta-CN-73, which contributed 17.5% of the total serum PCN concentration. Enrichment of hepta-CN-73 in the human serum samples might be due to contributors from combustion sources.  相似文献   

17.
The subject of this study was to develop a method of simultaneous determination of PCDDs/PCDFs and HCB in exhaust gases from industrial installations. Sampling to determine PCDDs/PCDFs was conducted using the method described in PN-EN 1948-1: 2006, where the sorption material is polyurethane foam (PUF). In order to simultaneously collect PCDDs/PCDFs and HCB and to avoid sorbent bed breakthrough, it was necessary to apply an additional polyurethane sorption layer. Twenty-seven samples of exhaust gases from various cement plants and 40 samples of exhaust gases from hospital and industrial waste incineration plants collected in 2009/2010 in the entire territory of Poland were examined. The average content of PCDDs/Fs in samples from cement plants amounted to 0.076 ng I-TEQ N m(-3) (range of 0.002-0.62 ng I-TEQ N m(-3)), while the average content of HCB amounted to 10 ng N m(-3) (range of 0.98-60.5 ng N m(-3)). In the case of samples collected from waste incineration plants, the average concentration of PCDDs/Fs was 0.39 ng I-TEQN m(-3) (range of 0.002-5.68 ng I-TEQ N m(-3)). In the case of HCB, the average concentration was 238 ng N m(-3) (range of 3.21-2500 ng N m(-3)). Also, the interdependence of the concentration of PCDDs/PCDFs and HCB was determined in the analysed samples, with the ranges of low and high content of PCDDs/PCDFs being examined separately. In all cases, the determined values of the r correlation coefficient were within the range of 0.7-1.0, which indicates a good correlation between the concentrations of PCDDs/PCDFs and HCB.  相似文献   

18.
The major sources of dioxins (polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and dioxin-like polychlorinated biphenyls (DL-PCBs)) in the environment in Japan have been considered to be combustion by-products, pentachlorophenol (PCP) formulations, chlornitrofen (CNP, 4-nitrophenyl-2,4,6-trichlorophenyl ether) formulations, and PCB products. Data on PCDDs, PCDFs and DL-PCBs from the four sources were analyzed, and indicative congeners whose concentrations were highly correlated with WHO-2006 toxic equivalencies (TEQs) were identified for each source sample. The indicative congeners for combustion by-products, PCP formulations, and CNP formulations were 2,3,4,7,8-pentachlorodibenzofuran, 1,2,3,4,6,7,8-heptachlorodibenzo-p-dioxin, and 1,2,3,7,8-pentachlorodibenzo-p-dioxin, respectively; for PCB products, the indicative congeners were IUPAC Nos. #126- and #105-pentachlorobiphenyls. Moreover, using the data on PCDDs, PCDFs and DL-PCBs, we developed a set of equations for estimating the apportionment of TEQs from the four sources by using only the concentrations of the above-mentioned five indicative congeners. The equations were used along with the analysis results of different types of environmental samples collected from Japan, to determine the TEQ contributions of the four sources. The obtained values of TEQ contributions seemed to be reasonable. The estimation method was developed by using the data on major dioxin sources in Japan, and therefore, it is generally adaptable to environmental samples from any part of Japan. The method may be usable for regions outside Japan if source identification is carried out and the estimation equations are modified appropriately.  相似文献   

19.
A comprehensive air toxics measurements program designed to establish baseline concentrations of atmospheric polychlorinated dioxins and dibenzofurans (PCDDs/PCDFs) in the South Coast Air Basin has been completed. The program utilized state-of-the-art air sampling and laboratory analysis techniques (HRGC/HRMS) to quantify the fifteen 2,3,7,8-substituted PCDDs/PCDFs congeners of primary toxicological significance. This study, which included nine discrete sampling sessions between December 1987 and March 1989, provides the first systematic assessment of ambient PCDDs/PCDFs concentrations in the state of California. The highest PCDDs/PCDFs concentrations noted during this study occurred in December 1987. This period was dominated by off-shore air flows, suggesting a regional air mass and transport phenomena. Concentrations of the PCDDs/PCDFs were diminished markedly in subsequent sampling sessions where air flow patterns were primarily of on-shore or of coastal origin. Ambient PCDDs/PCDFs concentrations, expressed as toxic equivalents, were highest during the December 1987 sampling period. The El Toro monitoring site, located approximately 40 miles southeast of Los Angeles, consistently showed the lowest measured ambient PCDDs/PCDFs concentrations and toxic equivalents values. In the majority of the sessions and samples examined the PCDDs/PCDFs congener profiles strongly suggest combustion source influences. Typical of combustion source profiles, 1,2,3,4,6,7,8-HpCDD was the predominant 2,3,7,8-substituted species and most prevalent PCDD after OCDD. The congener of highest toxicological significance, 2,3,7,8-TCDD, was reported below the 10-20 fg/m3 detection limit for most of the ambient air samples selected for analysis.  相似文献   

20.
John J. Ryan 《Chemosphere》1986,15(9-12):1585-1593
A number of chlorinated dibenzo-p-dioxins (PCDDs) and chlorinated dibenzofurans (PCDFs) occur in human adipose tissue at levels from 5 pg/g for 2, 3, 7, 8-TCDD to approximately 1000 pg/g for octachlorodibenzo-p-dioxin (OCDD). The variation of these compounds in tissues has been studied with respect to age, sex, tissue type, and country. A sampling of 46 adipose tissues from Canada in 1976 has shown a positive correlation of 2,3,7,8-TCDD level of detectable samples with age but not sex. This relationship is supported by the analysis for the first time of tissue from a 6 month old infant and the demonstration of little or no measurable levels of PCDDs/PCDFs. Three additional tissue types, pancreas, brain, and testis, from two autopsies were assayed for PCDDs/PCDFs for the first time but little or none were found even though the first two tissues had up to 10% lipid. A small sampling of adipose tissue from the general population in Japan in 1984 contained generally the same types and concentrations of PCDDs/PCDFs as are found in tissues from other industrialized countries.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号