首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 140 毫秒
1.
以枯草芽孢杆菌芽孢为模型微生物,研究了实际水体中单独氯消毒、单独臭氧消毒和臭氧-自由氯联合作用的灭菌效果.结果表明,枯草芽孢杆菌芽孢对单独氯消毒的抗性很大,6 mg/L氯作用240 min后灭活率仅为0.84个对数级;臭氧对枯草芽孢杆菌芽孢有较好的灭活效果,臭氧作用5 min,对其有4.68个对数级的灭活率.与单独氯消...  相似文献   

2.
The aim of this study was to measure the air concentrations of carbon dioxide (CO2) and formaldehyde (HCHO) in daycare centers to determine relevant influencing factors, including temperature, relative humidity (RH), type of facility, number of children, type of ventilation system, ventilation time, and air cleaning system. The authors measured HCHO, CO2, temperature, and RH in the center of classrooms in 289 daycare centers. Spearman’s correlation and Mann–Whitney analyses were used to examine the relationships and differences in HCHO and CO2 for varying temperatures, RH values, and categorical indoor environmental factors. There were no significant differences in the HCHO and CO2 air concentrations with varying numbers of children, ventilation times, or ventilation and air cleaning system types. However, both the HCHO and CO2 air concentrations were significantly different for varying RH values, which were divided into five categories (p < 0.001). Only the HCHO air concentrations were significantly different for varying temperatures, which were divided into five categories (p < 0.001). Significant correlations were found between HCHO air concentrations and the temperature (r = 0.35, p < 0.0001), RH (r = 0.51, p < 0.0001), and CO2 (r = 0.36, p < 0.0001). The study results support maintaining an appropriate temperature and RH range for reducing airborne HCHO in daycare centers. Further research is needed to elucidate the precise mechanisms responsible for the relationships observed in this study.

Implications: Data from 289 daycare centers in Seoul, South Korea, indicate that HCHO concentrations show a positive correlation with indoor temperature and relative humidity. This indicates that keeping temperatures low will help keep HCHO concentrations low, by both a direct and an indirect effect, since low temperatures also cause low relative humidity.  相似文献   


3.
In Korea, the amount of greenhouse gases released due to waste materials was 14,800,000 t CO2eq in 2012, which increased from 5,000,000 t CO2eq in 2010. This included the amount released due to incineration, which has gradually increased since 2010. Incineration was found to be the biggest contributor to greenhouse gases, with 7,400,000 t CO2eq released in 2012. Therefore, with regards to the trading of greenhouse gases emissions initiated in 2015 and the writing of the national inventory report, it is important to increase the reliability of the measurements related to the incineration of waste materials.

This research explored methods for estimating the biomass fraction at Korean MSW incinerator facilities and compared the biomass fractions obtained with the different biomass fraction estimation methods. The biomass fraction was estimated by the method using default values of fossil carbon fraction suggested by IPCC, the method using the solid waste composition, and the method using incinerator flue gas.

The highest biomass fractions in Korean municipal solid waste incinerator facilities were estimated by the IPCC Default method, followed by the MSW analysis method and the Flue gas analysis method. Therefore, the difference in the biomass fraction estimate was the greatest between the IPCC Default and the Flue gas analysis methods. The difference between the MSW analysis and the flue gas analysis methods was smaller than the difference with IPCC Default method. This suggested that the use of the IPCC default method cannot reflect the characteristics of Korean waste incinerator facilities and Korean MSW.

Implications: Incineration is one of most effective methods for disposal of municipal solid waste (MSW). This paper investigates the applicability of using biomass content to estimate the amount of CO2 released, and compares the biomass contents determined by different methods in order to establish a method for estimating biomass in the MSW incinerator facilities of Korea. After analyzing the biomass contents of the collected solid waste samples and the flue gas samples, the results were compared with the Intergovernmental Panel on Climate Change (IPCC) method, and it seems that to calculate the biomass fraction it is better to use the flue gas analysis method than the IPCC method. It is valuable to design and operate a real new incineration power plant, especially for the estimation of greenhouse gas emissions.  相似文献   


4.
The overall objective of this paper was to evaluate five different technologies used for infectious medical waste treatment and select the optimum one by means of multicriteria analysis. Steam disinfection was selected as the optimum treatment technology, among others using incineration, microwave disinfection, chemical disinfection with sodium hypochlorite, and reverse polymerization with microwaves. The evaluation was based on four groups of criteria, specifically, environmental, economic, technical, and social criteria, using the analytic hierarchy process. Selection among four commercial systems using steam disinfection was not possible, because it required additional site-specific criteria, e.g., loading capacity and requirements of local regulations.

Implications: The paper can help health care facilities to select the system for infectious waste treatment that best fits their needs. It was concluded that steam disinfection was the optimum technology, using environmental, economic, technical, and social criteria.  相似文献   


5.
ABSTRACT

Gaseous chlorine dioxide (ClO2) is one of the most promising air disinfectants. In this study, an ultra-low concentration of ClO2 gas (< 1.2 mg/m3) was generated in an office at various levels of humidity and illuminance to investigate the decay law. The disinfection efficiency and metal corrosiveness of ultra-low concentrations of ClO2 gas were also studied using an experimental chamber. At 48% and 75% humidity, the decay rate constants of ClO2 gas were 0.0034 min?1 and 0.0036 min?1, respectively. The rate of decline of the ClO2 concentration increased as the humidity of the environment increased. The decay rate constant of ClO2 gas at an illuminance of 76 lux and 3429 lux was 0.0034 min?1 and 0.00427 min?1, respectively; hence, the decay rate increased with increased illumination. At a humidity of 72% and illuminance of 2112 lux, the decay rate constant reached 0.00880 min?1. The effects of humidity and illuminance on the attenuation of the ClO2 concentration were strongly synergistic. When the gas concentration was maintained below 0.9 mg/m3, the disinfection rate of ClO2 on bacteria (P. aeruginosa, V. mimicus and S. aureus) exceeded 99.9%; thus, ClO2 gas exhibited a high disinfection efficiency. In addition, there was no corrosion to various metals by ClO2 under the same conditions. Consequently, gaseous ClO2 at ultra-low concentrations has a high sterilization efficiency and is non-corrosive to metals.  相似文献   

6.
A long-term monitoring of composition of landfill gases in the region with high rainfall was conducted using an argon assay in order to discuss air intrusion into the dump site. Gas samples were taken from vertical gas monitoring pipes installed along transects at two sections (called new and old) of an abandoned waste dump site in Sri Lanka. N2O concentrations varied especially widely, by more than three orders of magnitude (0.046–140 ppmv). The nitrogen/argon ratio of landfill gas was normally higher than that of fresh air, implying that denitrification occurred in the dump site. Argon assays indicate that both N2 and N2O production occurred inside waste and more significantly in the old section. The Ar assay would help for evaluations of N2O emission in developing countries.

Implications: A long-term monitoring of composition of landfill gases in the region with high rainfall was conducted using an argon assay in order to discuss air intrusion into the dump site. Argon assays indicate that both N2 and N2O production occurred inside waste and more significantly in the old section.  相似文献   


7.
This study aims at evaluating and comparing pollution removal in wastewater treatment via the use of probiotics alone or in combination under aerobic conditions in diurnal cycles. Herein, 650 mL of organic wastewater was stored in 1-L conical flasks and then randomly divided into three treatment groups, each experiment was repeated three times. Group A was supplemented with 2% (v/v) photosynthetic bacteria (PSB; Rhodopseudomonas palustris) alone; group B was supplemented with 2% (v/v) B. subtilis alone; and group C was supplemented with 1% (v/v) PSB and 1% (v/v) B. subtilis. Results showed that the pH increases were in the order: group A < group C < group B. The performance of the probiotics in terms of ammonia nitrogen and total nitrogen (TN) removal was in the order: group A < group C < group B, whereas in terms of total organic matter (TOC) and total carbon (TC) removal, the order was group C < group B < group A. These results showed that the effect of probiotics combination treatment on ammonia nitrogen and TN removal was better than that of using B. subtilis alone, but worse than that of using PSB alone. The effect of B. subtilis alone treatment on TOC and TC removal was better than that of using PSB alone, but the combination of PSB and B. subtilis showed greater benefits on TOC and TC removal.

Implications: Photosynthetic bacteria and B. subtilis were used in this study to investigate carbon and nitrogen metabolism via the use of different probiotics and then study further on comparing and achieving the best pollution removal performance in probiotics alone or in combination treatment. To make observations realistic, the experiments were conducted under aerobic conditions in a diurnal cycle environment.  相似文献   


8.
Use of vent-free gas heating appliances for supplemental heating in U.S. homes is increasing. However, there is currently a lack of information on the potential impact of these appliances on indoor air quality for homes constructed according to energy-efficient and green building standards. A probabilistic analysis was conducted to estimate the impact of vent-free gas heating appliances on indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen in “tight” energy-efficient homes in the United States. A total of 20,000 simulations were conducted for each Department of Energy (DOE) heating region to capture a wide range of home sizes, appliance features, and conditions, by varying a number of parameters, e.g., room volume, house volume, outdoor humidity, air exchange rates, appliance input rates (Btu/hr), and house heat loss factors. Predicted airborne levels of CO were below the U.S. Environmental Protection Agency (EPA) standard of 9 ppm for all modeled cases. The airborne concentrations of NO2 were below the U.S. Consumer Product Safety Commission (CPSC) guideline of 0.3 ppm and the Health Canada benchmark of 0.25 ppm in all cases and were below the World Health Organization (WHO) standard of 0.11 ppm in 99–100% of all cases. Predicted levels of CO2 were below the Health Canada standard of 3500 ppm for all simulated cases. Oxygen levels in the room of vent-free heating appliance use were not significantly reduced. The great majority of cases in all DOE regions were associated with relative humidity (RH) levels from all indoor water vapor sources that were less than the EPA-recommended 70% RH maximum to avoid active mold and mildew growth. The conclusion of this investigation is that when installed in accordance with the manufacturer’s instructions, vent-free gas heating appliances maintain acceptable indoor air quality in tight energy-efficient homes, as defined by the standards referenced in this report.

Implications: Probabilistic modeling of indoor air concentrations of carbon monoxide (CO), nitrogen dioxide (NO2), carbon dioxide (CO2), water vapor, and oxygen associated with use of vent-free gas heating appliances provides new data indicating that uses of these devices are consistent with acceptable indoor air quality in “tight” energy-efficient homes in the United States. This study will provide authoritative bodies such as the International Code Council with definitive information that will assist in the development of future versions of national building codes, and will provide evaluation of the performance of unvented gas heating products in energy conservation homes.  相似文献   


9.
In 2012, the WHO classified diesel emissions as carcinogenic, and its European branch suggested creating a public health standard for airborne black carbon (BC). In 2011, EU researchers found that life expectancy could be extended four to nine times by reducing a unit of BC, vs reducing a unit of PM2.5. Only recently could such determinations be made. Steady improvements in research methodologies now enable such judgments.

In this Critical Review, we survey epidemiological and toxicological literature regarding carbonaceous combustion emissions, as research methodologies improved over time. Initially, we focus on studies of BC, diesel, and traffic emissions in the Western countries (where daily urban BC emissions are mainly from diesels). We examine effects of other carbonaceous emissions, e.g., residential burning of biomass and coal without controls, mainly in developing countries.

Throughout the 1990s, air pollution epidemiology studies rarely included species not routinely monitored. As additional PM2.5. chemical species, including carbonaceous species, became more widely available after 1999, they were gradually included in epidemiological studies. Pollutant species concentrations which more accurately reflected subject exposure also improved models.

Natural “interventions” - reductions in emissions concurrent with fuel changes or increased combustion efficiency; introduction of ventilation in highway tunnels; implementation of electronic toll payment systems – demonstrated health benefits of reducing specific carbon emissions. Toxicology studies provided plausible biological mechanisms by which different PM species, e.g., carbonaceous species, may cause harm, aiding interpretation of epidemiological studies.

Our review finds that BC from various sources appears to be causally involved in all-cause, lung cancer, and cardiovascular mortality, morbidity, and perhaps adverse birth and nervous system effects. We recommend that the U.S. EPA rubric for judging possible causality of PM2.5. mass concentrations, be used to assess which PM2.5. species are most harmful to public health.

Implications: Black carbon (BC) and correlated co-emissions appear causally related with all-cause, cardiovascular, and lung cancer mortality, and perhaps with adverse birth outcomes and central nervous system effects. Such findings are recent, since widespread monitoring for BC is also recent. Helpful epidemiological advances (using many health relevant PM2.5 species in models; using better measurements of subject exposure) have also occurred. “Natural intervention” studies also demonstrate harm from partly combusted carbonaceous emissions. Toxicology studies consistently find biological mechanisms explaining how such emissions can cause these adverse outcomes. A consistent mechanism for judging causality for different PM2.5 species is suggested.

A list of acronyms will be found at the end of the article.  相似文献   


10.
In the gasification of biomass, it is necessary to limit the amount of by-product tar and increase the yields of hydrogen (H2) and carbon monoxide (CO) (syngas). Therefore, we conducted gasification and reforming experiments on woody biomass using an electric tubular furnace, to evaluate the gas reforming and tar decomposition performance of a NiO/SBA-15 catalyst. As a result, we found that this catalyst is effective for H2 production. It is believed that the increase in H2 volume due to the catalyst occurs through a steam reforming reaction involving hydrocarbons, including methane (CH4), and the water-gas shift reaction. With respect to the influence of the gasifying agent on the reforming effect of the catalyst, the amount of generated carbon dioxide (CO2) and hydrogen (H2) increases because the shift reaction is promoted by supplying steam. On the other hand, it was inferred that the shift reaction rarely occurred because it approaches equilibrium by supplying O2. Furthermore, it is suggested that light aromatic hydrocarbons are decomposed by the catalyst.

Implications: The mesoporous silica catalyst NiO/SBA-15 was highly effective for H2 production and decomposition of light aromatic compounds in the gasification of woody biomass. In the catalyst reaction, supplying steam promoted H2 production. From thermodynamic analysis and discussion, it was also inferred that supplying O2 might prevent the water gas shift reaction. The results are useful for designing a process needed for rich H2 production and gas refining process for further use of syngas.  相似文献   


11.
The primary goal of this paper is to reveal the reaction behavior of SO2 in the sinter zone, combustion zone, drying–preheating zone, and over-wet zone during flue gas recirculation (FGR) technique. The results showed that SO2 retention in the sinter zone was associated with free-CaO in the form of CaSO3/CaSO4, and the SO2 adsorption reached a maximum under 900ºC. SO2 in the flue gas came almost from the combustion zone. One reaction behavior was the oxidation of sulfur in the sintering mix when the temperature was between 800 and 1000ºC; the other behavior was the decomposition of sulfite/sulfate when the temperature was over 1000ºC. However, the SO2 adsorption in the sintering bed mainly occurred in the drying–preheating zone, adsorbed by CaCO3, Ca(OH)2, and CaO. When the SO2 adsorption reaction in the drying–preheating zone reached equilibrium, the excess SO2 gas continued to migrate to the over-wet zone and was then absorbed by Ca(OH)2 and H2O. The emission rising point of SO2 moved forward in combustion zone, and the concentration of SO2 emissions significantly increased in the case of flue gas recirculation (FGR) technique.

Implications: Aiming for the reuse of the sensible heat and a reduction in exhaust gas emission, the FGR technique is proposed in the iron ore sintering process. When using the FGR technique, SO2 emission in exhaust gas gets changed. In practice, the application of the FGR technique in a sinter plant should be cooperative with the flue gas desulfurization (FGD) technique. Thus, it is necessary to study the influence of the FGR technique on SO2 emissions because it will directly influence the demand and design of the FGD system.  相似文献   


12.
Significant amounts of volatile organic compounds and greenhouse gases are generated from wastewater lagoons and tailings ponds in Alberta, Canada. Accurate measurements of these air pollutants and greenhouse gases are needed to support management and regulatory decisions. A mobile platform was developed to measure air emissions from tailings pond in the oil sands region of Alberta. The mobile platform was tested in 2015 in a municipal wastewater treatment lagoon. With a flux chamber and a CO2/CH4 sensor on board, the mobile platform was able to measure CO2 and CH4 emissions over two days at two different locations in the pond. Flux emission rates of CO2 and CH4 that were measured over the study period suggest the presence of aerobic and anaerobic zones in the wastewater treatment lagoon. The study demonstrated the capabilities of the mobile platform in measuring fugitive air emissions and identified the potential for the applications in air and water quality monitoring programs.

Implications: The Mobile Platform demonstrated in this study has the ability to measure greenhouse gas (GHG) emissions from fugitive sources such as municipal wastewater lagoons. This technology can be used to measure emission fluxes from tailings ponds with better detection of spatial and temporal variations of fugitive emissions. Additional air and water sampling equipment could be added to the mobile platform for a broad range of air and water quality studies in the oil sands region of Alberta.  相似文献   


13.
In this study, in order to understand accurate calculation of greenhouse gas emissions of urban solid waste incineration facilities, which are major waste incineration facilities, and problems likely to occur at this time, emissions were calculated by classifying calculation methods into 3 types. For the comparison of calculation methods, the waste characteristics ratio, dry substance content by waste characteristics, carbon content in dry substance, and 12C content were analyzed; and in particular, CO2 concentration in incineration gases and 12C content were analyzed together. In this study, 3 types of calculation methods were made through the assay value, and by using each calculation method, emissions of urban solid waste incineration facilities were calculated then compared. As a result of comparison, with Calculation Method A, which used the default value as presented in the IPCC guidelines, greenhouse gas emissions were calculated for the urban solid waste incineration facilities A and B at 244.43 ton CO2/day and 322.09 ton CO2/day, respectively. Hence, it showed a lot of difference from Calculation Methods B and C, which used the assay value of this study. It is determined that this was because the default value as presented in IPCC, as the world average value, could not reflect the characteristics of urban solid waste incineration facilities. Calculation Method B indicated 163.31 ton CO2/day and 230.34 ton CO2/day respectively for the urban solid waste incineration facilities A and B; also, Calculation Method C indicated 151.79 ton CO2/day and 218.99 ton CO2/day, respectively.

Implications: This study intends to compare greenhouse gas emissions calculated using 12C content default value provided by the IPCC (Intergovernmental Panel on Climate Change) with greenhouse gas emissions calculated using 12C content and waste assay value that can reflect the characteristics of the target urban solid waste incineration facilities. Also, the concentration and 12C content were calculated by directly collecting incineration gases of the target urban solid waste incineration facilities, and greenhouse gas emissions of the target urban solid waste incineration facilities through this survey were compared with greenhouse gas emissions, which used the previously calculated assay value of solid waste.  相似文献   


14.
The formation of PM2.5 (aerosol particulate matter less than 2.5 µm in aerodynamic diameter) in association with SO2 emission during sintering process has been studied by dividing the whole sintering process into six typical sampling stages. A low-pressure cascade impactor was used to collect PM2.5 by automatically segregating particulates into six sizes. It was found that strong correlation existed between the emission properties of PM2.5 and SO2. Wet mixture layer (overwetted layer and raw mixture layer) had the function to simultaneously capture SO2 and PM2.5 during the early sintering stages, and released them back into flue gas mainly in the flue gas temperature-rising period. CaSO4 crystals constituted the main SO2-related PM2.5 during the disappearing process of overwetted layer, which was able to form perfect individual crystals or to form particles with complex chemical compositions. Besides the existence of individual CaSO4 crystals, mixed crystals of K2SO4-CaSO4 in PM2.5 were also found during the first half of the temperature-rising period of flue gas. The interaction between fine-grained Ca-based fluxes, potassium vapors, and SO2 was the potential source of SO2-related PM2.5.

Implications: The emission property of PM2.5 and SO2 throughout the sintering process exhibited well similarity. This phenomenon tightened the relationship between the formation of PM2.5 and the emission of SO2. Through revealing the properties of SO2-related PM2.5 during sintering process, the potential interaction between fine-grained Ca-based fluxes, potassium vapors, and SO2 was found to be the source of SO2-related PM2.5. This information can serve as the guidance to develop efficient techniques to control the formation and emission of PM2.5 in practical sintering plants.  相似文献   


15.
The concentrations of fine particles and selected gas pollutants in the flue gas entering the stack were measured under several common operation modes in an operating coal power plant producing electricity. Particle size distributions in a diameter range from 10 nm to 20 μm were measured by a scanning mobility particle sizer (SMPS), and the flue gas temperature and concentrations of CO2 and SO2 were monitored by a continuous emission monitoring system (CEMS). During the test campaign, five plant operating modes were studied: soot blowing, bypass of flue-gas desulfurization (FGD), reheat burner operating at 0% (turned off), 27%, and 42% (normal condition) of its full capacity. For wet and dry aerosols, the measured mode sizes were both around 40 nm, but remarkable differences were observed in the number concentrations (#/cm3, count per square centimeter). A prototype photoionizer enhanced electrostatic precipitator (ESP) showed improved removal efficiency of wet particles at voltages above +11.0 kV. Soot blowing and FGD bypass both increased the total particle number concentration in the flue gas. The temperature was slightly increased by the FGD bypass mode and varied significantly as the rating of reheat burner changed. The variations of CO2 and SO2 emissions showed correlations with the trend of total particle number concentration possibly due to the transitions between gas and particle phases. The results are useful in developing coal-fired power plant operation strategies to control fine particle emissions and developing amine-based CO2 capture technologies without operating and environmental concerns associated with volatile amine emissions.

Implications: The measurement of the fine particle size distributions in the exhaust gas under several common operating conditions of a coal-fired power plant revealed different response relations between aerosol number concentration and the operating condition. A photo-ionizer enhanced ESP was demonstrated to capture fine particles with higher efficiency compared to conventional ESPs, and the removal efficiency increased with the applied voltage. The characteristic information of aerosols and main gaseous pollutants in the exhaust gas is extremely important for developing and deploying CO2 scrubbers, whose amine emissions and operating effectiveness depends greatly on the upstream concentrations of fine particles, SO2, from the power plant.  相似文献   


16.
With increasing attention on sulfuric acid emission, investigations on the removal characteristics of sulfuric acid aerosols by the limestone gypsum wet flue gas desulfurization (WFGD) system and the wet electrostatic precipitator (WESP) were carried out in two coal-fired power plants, and the effects of the WFGD scrubber type and the flue gas characteristics were discussed. The results showed that it was necessary to install the WESP device after desulfurization, as the WFGD system was inefficient to remove sulfuric acid aerosols from the flue gas. The removal efficiency of sulfuric acid aerosols in the WFGD system with double scrubbers ranged from 50% to 65%, which was higher than that with a single scrubber, ranging from 30% to 40%. Furthermore, the removal efficiency of WESP on the sulfuric acid aerosols was from 47.9% to 52.4%. With increased concentrations of SO3 and particles in the flue gas, the removal efficiencies of the WFGD and the WESP on the sulfuric acid aerosols were increased.

Implications: Investigations on removal of sulfuric acid aerosols by the WFGD and the WESP in the power plants were aimed at the control of sulfuric acid emission. The results showed that the improvement of the WFGD system was beneficial for the reduction of sulfuric acid emission, while the WESP system was essential to control the final sulfuric acid aerosol concentration.  相似文献   


17.
To develop standard toxic gas mixtures, it is essential to identify adsorption characteristics of each toxic gas on the inner surface of a gas cylinder. Thus, this study quantified adsorbed amounts of the four toxic gases (nitric oxide [NO], nitrogen dioxide [NO2], sulfur dioxide [SO2], and hydrogen chloride [HCl]) on the inner surface of aluminum cylinders and nickel-coated manganese steel cylinders. After eluting adsorbed gases on the inside of cylinders with ultrapure water, a quantitative analysis was performed on an ion chromatograph. To evaluate the reaction characteristics of the toxic gases with cylinder materials, quantitative analyses of nickel (Ni), iron (Fe), and aluminum (Al) were also performed by inductively coupled plasma optical emission spectrometry (ICP-OES). It was found that the amounts of NO, NO2, and SO2 adsorbed on the inner surface of aluminum cylinders were less than 1.0% at the level of 100 μmol/mol mixing ratio, whereas the signal for most heavy metal elements were below their respective detection limits. This study found that the amounts of HCl adsorbed on the inner surface of nickel-coated manganese steel cylinders were less than 5% at the level of 100 μmol/mol mixing ratio, whereas Ni (86 μmol) and Fe (28 μmol) were detected in the same cylinders. It was revealed that the adsorption mainly took place via the reaction of HCl with inner surface material of nickel-coated manganese steel cylinders. On the other hand, in the case of aluminum cylinders, the amounts of the adsorption were determined to be less than 1% at the level of HCl 100 μmol/mol mixing ratio, whereas most of Ni, Fe, and Al were detected at levels similar to their limits of detection. As a result, this study found that aluminum cylinders are more suitable for preparing HCl gas mixtures than nickel-coated manganese steel cylinders.

Implications: To develop a standard toxic gas mixture, it is essential to understand the adsorption characteristics of each toxic gas inside a gas cylinder. It was found that the amounts of NO, NO2, and SO2 adsorbed inside aluminum cylinders were less than 1.0% at the level of 100 μmol/mol mixing ratio. The amounts of HCl adsorbed inside nickel-coated manganese steel cylinders were less than 5% at the level of 100 μmol/mol mixing ratio, whereas those inside aluminum cylinders were less than 1%, indicating that aluminum cylinders are more suitable for preparing HCl gas mixtures.  相似文献   


18.
Patches of dung and urine are major contributors to the feedlot gas emissions. This study investigated the impacts of dung deposition frequency (partly reflecting animal stocking density of a feedlot), dairy feedlot floor conditions (old floor indicated with the presence of consolidated manure pad [CMP] vs. new floor with the absence of consolidated manure pad [CMPn]), and application of dicyandiamide (DCD) and hydroquinone (HQ) on nitrous oxide (N2O) and methane (CH4) emissions from patches in the laboratory, and the integrative impacts were expressed in terms of global warming potential (CO2-equivalent). Dung deposition frequency, feedlot floor condition, and application of inhibitors showed inverse impacts on N2O and CH4 emissions from patches. Greenhouse gas (GHG) emissions from the dung, urine, and dung+urine patches on the CMP feedlot surface were approximately 7.48, 87.35, and 7.10 times those on the CMPn feedlot surface (P < 0.05). Meanwhile, GHG emissions from CMP and CMPn feedlot surfaces under high deposition frequency condition were approximately 10 and 1.7 times those under low-frequency condition. Moreover, application of HQ slightly reduced the GHG emission from urine patches, by 14.9% (P > 0.05), while applying DCD or DCD+HQ significantly reduced the GHG, by 60.3% and 65.0%, respectively (P < 0.05). Overall, it is necessary to include feedlot management such as animal stocking density and feedlot floor condition to the process of determining emission factors for feedlots. In the future, field measurements to quantitatively evaluate the relative contribution of nitrification and denitrification to the N2O emissions of feedlot surfaces are highly required for effective N2O control.

Implications: This study shows that feedlot CH4 and N2O emissions inversely respond to the dicyandiamide (DCD) application. Applying DCD significantly reduces GHG emissions of feedlot urine patches. Feedlot floor condition and stocking density strongly impact feedlot GHG emissions. Including feedlot floor condition and stocking density in the feedlot EF determining process is necessary.  相似文献   


19.
It is known that in-vehicle carbon dioxide (CO2) concentration tends to increase due to occupant exhalation when the HVAC (heating, ventilation, and air conditioning) air is in recirculation mode. Field experiments were conducted to measure CO2 concentration during typical commute in Bangkok, Thailand. The measured concentrations agreed with the concentration predicted using first-order mass balance equation, in both recirculating and outside air modes. The long-term transient decay of the concentration when the vehicle was parked and the HVAC system was turned off was also studied. This decay was found to follow Fickian diffusion process. The paper also provides useful operational details of the automotive HVAC system and fresh air ventilation exchange between cabin interior and exterior.

Implications: Drivers in tropical Asian countries typically use HVAC recirculation mode in their automobiles. This behavior leads to excessive buildup of cabin CO2 concentration levels. The paper describes the CO2 buildup in a typical commute in Bangkok, Thailand. Auto manufacturers can potentially take measures to alleviate such high concentration levels. The paper also discusses the diffusion of CO2 through the vehicle envelope, an area that has never been investigated before.  相似文献   


20.
A model was developed to simulate the sewage sludge gasification in an atmospheric fluidised bed gasifier using Aspen Plus. The model here presented was based on the Gibbs free energy minimisation and the restricted equilibrium method was used to calibrate it against previously published experimental data obtained in a lab-scale gasification plant. A sensitivity analysis of the model was carried out by modifying parameters such as the temperature, equivalence ratio (ER) and the steam-to-biomass ratio. The modeled results were in good agreement with the experimental data (especially when air was used as gasifying agent) and reproduced satisfactorily the experimental trends found for the gas composition, the carbon conversion (Xc) and the cold gas efficiency (CGE) under different gasification conditions. Operating at higher temperatures increased the production of H2 and CO, as well as the Xc and the CGE. The increase in ER produced higher Xc, yet the CGE experienced slight changes due to a decrease in the lower heating value of the resulting syngas, as well as the oxidation of combustible gases. The use of air+steam as gasifying agent increased the H2 content of the produced gases but decreased the accuracy of the model.

Implications: Gasification is an available alternative to produce energy as well as several raw materials from sewage sludge. The syngas obtained from this technology totally depends on the type of gasifier and the operation conditions, which can be optimized with the help of models. In this work, a relatively simple model was built using ASPEN PLUS. Despite its simplicity, the outputs of the model are in good agreement with experimental results what makes its use interesting for assessing scaling-up possibilities from lab-scale to pilot-scale gasification processes.  相似文献   