首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 93 毫秒
1.
The photodegradation of monuron (3-(4-chlorophenyl)-1,1-dimethylurea) in aqueous solutions under simulated solar irradiation has been conducted by different advanced oxidation processes (UV/H(2)O(2), UV/H(2)O(2)/Fe(2+), UV/H(2)O(2)/TiO(2), UV/TiO(2), dark H(2)O(2)/Fe(3+)). The degradation rates were always higher for the homogeneous catalysis in photo-Fenton reactions (UV/H(2)O(2)/Fe(2+)) compared to the heterogeneous photocatalytic systems (TiO(2)/UV and UV/H(2)O(2)/TiO(2)). Optimal concentrations of Fe(2+) and H(2)O(2) for the abatement of the herbicide in the photo-Fenton system were found to be 1 mM Fe(II) and 10 mM H(2)O(2). Several intermediary products were identified using large volume injection micro-liquid chromatography with UV detection (mu-LC-UV), mu-LC-MS and GC-MS techniques and a degradation mechanism has been proposed.  相似文献   

2.
将Fe3+负载在活性炭上制得载铁催化剂Fe/AC,并研究了该催化剂对邻苯二甲酸二甲酯(DMP)的催化降解性能。通过正交实验和单因素实验,探讨了催化剂投加量、H2O2投加量、溶液pH值和反应温度对水中DMP降解率的影响,同时对DMP矿化度进行了分析。实验结果表明,制得的载铁催化剂具有较高的催化活性;降解效果的影响顺序是反应温度〉催化剂投加量〉H2O2投加量〉溶液pH值;在反应温度为80℃、催化剂投加量为4 g/L、H2O2投加量为20 mL/L和溶液pH值为3的条件下反应120 min后,质量浓度为10 mg/L的DMP降解率最高可达97.73%;在优化的实验条件下反应150 min,DMP矿化度可达62.73%;催化剂反复使用5次仍具有较好的催化活性,DMP降解率仍可达到77%以上;反应过程中溶液Fe3+浓度的变化维持在1.07 mg/L左右,且可推测催化降解DMP主要是由非均相和均相催化氧化反应共同作用的。  相似文献   

3.
INTENTION, GOAL, SCOPE, BACKGROUND: Since the intermediate products of some compounds can be more toxic and/or refractory than the original compund itself, the development of innovative oxidation technologies which are capable of transforming such compounds into harmless end products, is gaining more importance every day. Advanced oxidation processes are one of these technologies. However, it is necessary to optimize the reaction conditions for these technologies in order to be cost-effective. OBJECTIVE: The main objectives of this study were to see if complete mineralization of 4-chlorophenol with AOPs was possible using low pressure mercury vapour lamps, to make a comparison of different AOPs, to observe the effect of the existence of other ions on degradation efficiency and to optimize reaction conditions. METHODS: In this study, photochemical advanced oxidation processes (AOPs) utilizing the combinations of UV, UV/H2O2 and UV/H2O2/Fe2+ (photo-Fenton process) were investigated in labscale experiments for the degradation and mineralization of 4-chlorophenol. Evaluations were based on the reduction of 4-chlorophenol and total organic carbon. The major parameters investigated were the initial 4-chlorophenol concentration, pH, hydrogen peroxide and iron doses and the effect of the presence of radical scavengers. RESULTS AND DISCUSSION: It was observed that the 4-chlorophenol degradation efficiency decreased with increasing concentration and was independent of the initial solution pH in the UV process. 4-chlorophenol oxidation efficiency for an initial concentration of 100 mgl(-1) was around 89% after 300 min of irradiation in the UV process and no mineralization was achieved. The efficiency increased to > 99% with the UV/H2O2 process in 60 min of irradiation, although mineralization efficiency was still around 75% after 300 min of reaction time. Although the H2O2/4-CP molar ratio was kept constant, increasing initial 4-chlorophenol concentration decreased the treatment efficiency. It was observed that basic pHs were favourable in the UV/H2O2 process. The results showed that the photo-Fenton process was the most effective treatment process under acidic conditions. Complete disappearance of 100 mgl(-1) of 4-chlorophenol was achieved in 2.5 min and almost complete mineralization (96%) was also possible after only 45 min of irradiation. The efficiency was negatively affected from H2O2 in the UV/H2O2 process and Fe2+ in the photo-Fenton process over a certain concentration. The highest negative effect was observed with solutions containing PO4 triple ions. Required reaction times for complete disappearance of 100 mgl(-1) 4-chlorophenol increased from 2.5 min for an ion-free solution to 30 min for solutions containing 100 mgl(-1) PO4 triple ion and from 45 min to more than 240 min for complete mineralization. The photodegradation of 4-chlorophenol was found to follow the first-order law. CONCLUSION: The results of this study showed that UV irradiation alone can degrade 4-CP, although at very slow rates, but cannot mineralize the compound. The addition of hydrogen peroxide to the system, the so-called UV/H2O2 process, significantly enhances the 4-CP degradation rate, but still requires relatively long reaction periods for complete mineralization. The photo-Fenton process, the combination of homogeneous systems of UV/H2O2/Fe2+ compounds, produces the highest photochemical elimination rate of 4-CP and complete mineralization is possible to achieve in quite shorter reaction periods when compared with the UV/H2O2 process. RECOMMENDATIONS AND OUTLOOK: It is more cost effective to use these processes for only purposes such as toxicity reduction, enhancement of biodegradability, decolorization and micropollutant removal. However the most important point is the optimization of the reaction conditions for the process of concern. In such a case, AOPs can be used in combination with a biological treatment systems as a pre- or post treatment unit providing the cheapest treatment option. The AOP applied, for instance, can be used for toxicity reduction and the biological unit for chemical oxygen demand (COD) removal.  相似文献   

4.
The homogeneous degradation of the polychlorinated n-alkane, 1,2,9,10-tetrachlorodecane (T4C10), was studied in aqueous solutions of hydrogen peroxide, including Fenton and photo-Fenton reaction conditions. All solutions were adjusted to a pH of 2.8 and an ionic strength of 0.1 M NaClO4 prior to photolysis. T4C10 (2 x 10(-6) M) was substantially degraded by the H2O2/UV system (1.0 x 10(-2) M H2O2), with 60% disappearance in 20 min of irradiation in a photoreactor equipped with 300 nm lamps of light intensity 3.6 x 10(-5) Ein L(-1) min(-1) (established by ferrioxalate actinometry). The reaction produced stoichiometric amounts of chloride ion indicating complete dechlorination of the chlorinated n-alkane. T4C10 degraded very slowly under Fenton (Fe2+/H2O2/dark) and Fenton-like (Fe3+/H2O2/dark) conditions. However, when the same solutions were irradiated, T4C10 degraded more rapidly than in the H2O2/UV system, with 61% disappearance in 10 min of exposure. The rapid degradation is related to the enhanced degradation of hydrogen peroxide to oxidizing *OH radicals under photo-Fenton conditions. Degradation was inhibited in both the H2O2/UV and photo-Fenton systems by the addition of KI and tert-butyl alcohol due to *OH scavenging.  相似文献   

5.
Photo-oxidation of cork manufacturing wastewater   总被引:7,自引:0,他引:7  
Several photo-activated processes have been investigated for oxidation of a cork manufacturing wastewater. A comparative activity study is made between different homogeneous (H2O2/UV-Vis and H2O2/Fe2+/UV-Vis) and heterogeneous (TiO2/UV-Vis and TiO2/H2O2/UV-Vis) systems, with degradation performances being evaluated in terms of total organic carbon (TOC) removal. Results obtained in a batch photo-reactor show that photo-catalysis with TiO2 is not suitable for this kind of wastewater while the H2O2/UV-Vis oxidation process, for which the effect of some operating conditions was investigated, allows to remove 39% of TOC after 4 h of operation (for C(H2O2)=0.59 M, pH=10 and T=35 degrees C). The combined photo-activated process, i.e., using both TiO2 and H2O2, yields an overall TOC decrease of 46% (for C(TiO2)=1.0 gl(-1)). The photo-Fenton process proved to be the most efficient, proceeds at a much higher oxidation rate and allows to achieve 66% mineralization in just 10 min of reaction time (for C(H2O2)=0.31 M, T=30 degrees C, Fe2+:H2O2=0.12 (mol) and pH=3.2).  相似文献   

6.
BACKGROUND: Chlorophenols (CPs) constitute a group of organic pollutants that are introduced into the environment as a result of several man-made activities, such as uncontrolled use of pesticides and herbicides, and as byproducts in the paper pulp bleaching. Promising removal technologies of chlorinated aromatics consist in the application of advanced oxidation processes (AOPs) that can provide an almost total degradation of a variety of contaminants. Among these, wide application find Fenton systems based on generation of reactive species having a high oxidizing power, such as hydroxyl radical HO*. Our objective was that of determining the overall degradation efficiency of the model compound 2,4-dichlorophenol (DCP) by thermal Fenton-type oxidation systems with a view toward defining in more details relevant process parameters, the effect of reaction temperature and of co-catalyst Cu2+. METHODS: Reaction conditions were similar to those generally adopted as optimal in many practical applications, i.e. pollutant/Fe2+ (as FeSO4) ratio ca. 20, Fe2+/Cu2+ (co-catalyst) 2:1, pH adjusted and controlled at pH 3, and H2O2 in excess (up to four-fold over the stoichiometric amount required for complete mineralization). RESULTS AND DISCUSSION: The results demonstrate that it is advantageous to carry out the reaction at a temperature markedly higher (70 degrees C) than ambient. The stepwise addition of H2O2 in aliquots yields an efficient transformation, while allowing a convenient control of the reaction exothermicity. Under these conditions, the essentially complete removal of the initial DCP is accomplished using just one equiv of H2O2 during 15 min; excess H2O2 (5 equivalents) yields extensive substrate mineralization. Also relevant, at 70 degrees C dechlorination of the initial DCP (and of derived reaction intermediates) is remarkably extensive (3-5% residual TOX), already with the addition of 1 equiv of H2O2. At the end of the reaction, IC and IC-MS analyses of the solution reveal that only low-molecular weight carboxylic acid (acetic, formic, oxalic, malonic, tartaric, etc.) contribute to the residual TOC. CONCLUSIONS: The whole of the results herein point to the advantage of performing the process at temperatures substantially higher than ambient (70 degrees C). Under the conditions adopted, almost complete degradation of the initial toxic compound can be achieved using hydrogen peroxide in fair excess (e.g., 3.5 equiv H2O2). RECOMMENDATIONS AND OUTLOOK: In applying practical Fenton-type degradation systems to heavily polluted wastes, either for the pre-treatment of waters with a high COD value prior to biodegradation or for complete mineralization of pollutants, the set up of appropriate reaction conditions appears to be a key factor. Also, it is desirable to keep the concentration of iron salts within the lower limits in order to minimize the production and disposal of iron oxide sludges.  相似文献   

7.
以玻璃纤维为载体,将TiO2负载到其表面形成了空间玻璃纤维反应器,引入Fe3+作为掺杂改性离子,形成了负载TiO2/Fe3+的空间玻璃纤维光催化反应器,并以高压汞灯为光源进行了光催化降解水中苯酚的实验研究,考察了影响苯酚光催化降解的因素,确定了在UV365~250 W光源照射下,pH为3~5,O2通入量1.0 L/(min.L),反应器内上升流速为0.7 m/min等实验条件下,初始浓度为30 mg/L的苯酚废水经120 min光催化反应后,降解率可达到85%,矿化率可达80%。  相似文献   

8.
A comparative study is made of 12 methods of chemical oxidation applied to degrading p-hydroxybenzoic acid in aqueous solution. The oxidation processes tested were: UV, O3, UV/TiO2, O3/Fe2+, O3/H2O2, O3/UV, UV/H2O2, H2O2/Fe2+, H2O2/Fe2+/O3, UV/H2O2/O3, H2O2/Fe2+/UV and O3/UV/H2O2/Fe2+. The 12 processes were ranked by reactivity. In a kinetic study, the overall kinetic rate constant was split up into three components: direct oxidation by UV irradiation (photolysis), direct oxidation by ozone (ozonation), and oxidation by free radicals (mainly OH*).  相似文献   

9.
In this paper, a comparison of various advanced oxidation processes (O3, O3/UV, H2O2/UV, O3/H2O2/UV, Fe2+/H2O2) and chemical treatment methods using Al2(SO4)3.18H2O, FeCl3 and FeSO4 for the chemical oxygen demand (COD) and color removal from a polyester and acetate fiber dyeing effluent is undertaken. Advanced oxidation processes (AOPs) showed a superior performance compared to conventional chemical treatment, which maximum achievable color and COD removal for the textile effluent used in this study was 50% and 60%, respectively. Although O3/H2O2/UV combination among other AOPs methods studied in this paper was found to give the best result (99% removal for COD and 96% removal for color), use of Fe2+/H2O2 seems to show a satisfactory COD and color removal performance and to be economically more viable choice for the acetate and polyester fiber dyeing effluent on the basis of 90% removal.  相似文献   

10.
BACKGROUND: The spent waste of aliphatic chlorinated solvents has caused severe deterioration of groundwater quality. Trichloromethane (TCM), which shows health and toxicological effects on human beings, was selected as a model compound to be dechlorinated through a redox system. METHODS: The Fe0-based system including Fe0/H2O, Fe0/UV, Fe0/H2O2, and Fe0/UV/H2O2 was explored to evaluate its performance in dechlorinating TCM. H2O2 was dosed at later reaction time points to initiate Fenton or photo-Fenton reactions. The first two systems demonstrate the reductive dechlorination of TCM by Fe0-released electrons, while the latter two show dechlorination of TCM by both electron reduction and hydroxyl radical oxidation. The system parameters of TCM remaining, Cl- buildup, Fe2+ accumulation, H2O2 residue, and ORP were measured to describe different redox characteristics of TCM dechlorination. The Cl- buildup was used as a way to describe the degree of TCM dechlorination in an open reaction system. RESULTS: Reductive dechlorination efficiencies of TCM were 5% and 6% for the systems of Fe0/H2O and Fe0/UV, respectively. In contrast, the Fe/H2O2 and Fe0/UV/H2O2 systems were capable of dechlorinating TCM reductively and oxidatively by 14% and 15%, respectively. The presence of UV light was found to retard the dissolution of Fe2+, but it enhanced the rate of chloride buildup, based on the comparison of Fe0/H2O and Fe0/UV systems. In addition, WV irradiation plays only a minor role in the Fe0/UV/H2O2 system, in view of TCM dechlorination. Application of small amount of H2O2 results in the increase of Fe2+ accumulation rate in the Fe0/H2O2 system. CONCLUSIONS: TCM was dechlorinated mostly through post Fenton oxidation; reductive reaction represents a less efficient way to dechlorinate TCM. The efficiencies of overall TCM dechlorination for the two systems of Fe0/H2O2 and Fe0/UV/ H2O2 are comparable to each other, and this implies that the presence of UV irradiation imposes no significant enhancement. RECOMMENDATIONS AND OUTLOOKS: It is highly recommended to initiate effective redox dechlorination of TCM with the system of Fe0/H2O2, where the H2O2 in excess is applied at a later reaction time point.  相似文献   

11.
为了对水中苯酚的去除进行研究,通过离子交换法及液相沉积法在天然沸石上负载Fe3O4制备出一种具有较高反应活性的复合催化剂,采用X-射线衍射仪(XRD)、扫描电镜(SEM)等仪器对其结构和形貌进行表征,并利用复合催化剂进行非均相UV/Fenton反应处理模拟苯酚废水,考察不同因素对苯酚降解效果的影响。实验结果表明,在催化剂投加量为0.4 g/L,H2O2投加量为二分之一理论投加量,pH为3~10且室温的条件下,处理100 mg/L的模拟苯酚废水,60 min之内苯酚去除率可达90%以上。通过对催化剂的稳定性研究,发现经5次循环使用后,苯酚去除率均可保持在90%以上,具有良好的循环使用性能。  相似文献   

12.
以自制改性沸石为催化剂,通过微波诱导氧化技术,对活性嫩黄模拟废水进行氧化处理。采用尿素均匀沉淀包裹法制备Fe2O3/沸石微波诱导催化剂。利用SEM、XRD、IR等分析手段分别对催化剂的表面形态、物相结构等特性进行表征。实验考察了催化剂用量、微波辐射时间、微波辐射功率对活性嫩黄废水的降解效果。结果表明:在催化剂用量3g/L、微波功率900W、辐射时间4min的条件下,对50mg/L活性嫩黄的处理率达到97%。  相似文献   

13.
The photocatalytic removal kinetics of fenitrothion at a concentration of 0.5mgl(-1) in pure and natural waters were investigated in Fe(III)/H2O2/UV-Vis, Fe(III)/UV-Vis and H2O2/UV-Vis oxidation systems, with respect to decreases in fenitrothion concentrations with irradiation time using a solar simulator. Fenitrothion concentrations were determined by HPLC analysis. Furthermore, total mineralization of fenitrothion in these systems was evaluated by monitoring the decreases in DOC concentrations with solar simulator irradiation time by TOC analysis. It was shown that the degradation rate of fenitrothion was much faster in the Fe(III)/H2O2/UV-Vis system than the Fe(III)/UV-Vis and H2O2/UV-Vis systems in both pure and river waters. Consequently, the mineralization rate of fenitrothion was much faster in the Fe(III)/H2O2/UV-Vis system than in the other two systems. The high *OH generation rate measured in the Fe(III)/H2O2/UV-Vis system was the key to faster degradation of fenitrothion. Increases in the concentrations of H2O2 and Fe led to better final degradation of fenitrothion. These results suggest that the photo-Fenton reaction (Fe(III)/H2O2/UV-Vis) system is likely to be an effective method for removing fenitrothion from contaminated natural waters.  相似文献   

14.
Degradation of dyes in aqueous solutions by the Fenton process   总被引:3,自引:0,他引:3  
Xu XR  Li HB  Wang WH  Gu JD 《Chemosphere》2004,57(7):595-600
Degradation of 20 different dyes in aqueous solutions by the Fenton process was performed. These dyes include 6 types: acidic, reactive, direct, cationic, disperse and vat dyes. The former four types of dyes were decolorized and their TOC values were decreased greatly, while the color and TOC removals of the latter two types were lower. The catalytic activities of four metal ions on the degradation efficiencies of Vat Blue BO, which was chosen as a model dye because of its lowest color and TOC removals, were compared in the dark and under the ultraviolet light irradiation. The catalytic ability of different metals was Fe2+>Cu2+>Mn2+>Ag+ in the dark, and the same sequence was obtained under irradiation condition with greater degradation efficiency. Furthermore, the efficiencies of three oxidation processes, including H2O2/UV, Fe2+/H2O2 and Fe2+/H2O2/UV were compared. The results showed that the oxidation by Fe2+/H2O2/UV was the strongest, and even greater than the arithmetic sum of the other two processes, which suggests the synergistic effect of ultraviolet and ferrous ions on the degradation reaction.  相似文献   

15.
Degradation rates and removal efficiencies of Metronidazole using UV, UV/H2O2, H2O2/Fe2+, and UV/H2O2/Fe2+ were studied in de-ionized water. The four different oxidation processes were compared for the removal kinetics of the antimicrobial pharmaceutical Metronidazole. It was found that the degradation of Metronidazole by UV and UV/H2O2 exhibited pseudo-first order reaction kinetics. By applying H2O2/Fe2+, and UV/H2O2/Fe2+ the degradation kinetics followed a second order behavior. The quantum yields for direct photolysis, measured at 254 nm and 200-400 nm, were 0.0033 and 0.0080 mol E(-1), respectively. Increasing the concentrations of hydrogen peroxide promoted the oxidation rate by UV/ H2O2. Adding more ferrous ions enhanced the oxidation rate for the H2O2/Fe2+ and UV/H2O2/Fe2+ processes. The major advantages and disadvantages of each process and the complexity of comparing the various advanced oxidation processes on an equal basis are discussed.  相似文献   

16.
针对废水湿式双氧水催化氧化,采用浸渍法制备Cu催化剂,研究非均相Cu催化剂在常温常压湿式双氧水催化氧化中的稳定性与失活问题。研究表明,催化剂制备条件及催化氧化反应条件对催化剂中Cu2+溶出均有影响。研究同时表明,催化剂失活与活性组分流失和活性组分被有机中间产物覆盖有关,高温焙烧可对催化剂再生。  相似文献   

17.
Kwan CY  Chu W 《Chemosphere》2007,67(8):1601-1611
Recent studies have shown that hydrogen peroxide is generated in a ferrioxalate-induced photoreductive reaction, but information about the effect of organic ligands on the photochemical behaviour of ferrous species is limited. The degradation of the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) by a ferrous-catalyzed oxidation in the presence of various ligands such as formate, citrate, malelate, oxalate, and ethylenediaminetetra-acetic acid (EDTA) was studied. The experiments were conducted under either dark or irradiated (350n m) conditions. Forty-two percent and 34% of 2,4-D were removed by the Fe(2+)/oxalate/UV and Fe(2+)/citrate/UV processes, respectively, after 30 min of reaction and oxidative intermediates were obtained in both cases. The presence of hydroxylated intermediates suggests that 2,4-D may be attacked by hydroxyl radicals, which are the products of the photo-Fenton-like reaction. As such, hydrogen peroxide was produced by the photolysis of ferrous oxalate or ferrous citrate, referred to hereafter as photogenerated H(2)O(2). As expected, the total removal percentage of 2,4-D jumped to 97% when 1mM of hydrogen peroxide (so-called spiked H(2)O(2)) was externally added to the reaction vessel to initiate the Fe(2+)/oxalate/UV process. Therefore, the treatment of 2,4-D by the Fe(2+)/oxalate/H(2)O(2)/UV system can be operated in two steps: the photolysis of ferrous oxalate first, followed by adding the spiked H(2)O(2) sometime after the commencement of the reaction. A two-phase model has been developed to describe this tandem ferrous-catalyzed photooxidation, which would help to achieve the mineralization of 2,4-D.  相似文献   

18.
不同高级氧化法对水中低浓度药物甲硝唑降解过程的比较   总被引:3,自引:0,他引:3  
采用UV、H2O2、UV/H2O2、Fenton、UV/Fenton和UV/TiO2方法,对水中低浓度的药物甲硝唑进行降解。通过HPLC和UV-Vis光谱得到的甲硝唑去除率。详细讨论了Fe2+、TiO2和H2O2的初始浓度以及溶液的初始pH值对降解效率的影响。结果表明,UV/Fenton和UV/TiO2 2种系统对水中低浓度甲硝唑均有很好的去除效果,但前者的光催化效率更高。在甲硝唑浓度=6 μmol/L,H2O2和Fe2+的初始浓度分别为0.5 mg/L和2.94 μmol/L,pH=4的条件下,UV/Fenton方法对甲硝唑水溶液光催化的最佳效率为95.8%。  相似文献   

19.
以蒙脱土为载体制备负载型Fe/Al复合氧化物(FeAlOx/MMT)用于催化Fenton反应降解高浓度苯酚废水。实验结果表明,活性相FeAlOx中Fe/Al摩尔比为0.22时制备所得催化剂对Fenton反应具有最佳活性,且Fe/Al复合氧化物并未嵌入蒙脱土层间。在低温和高pH条件下催化体系存在诱导期,诱导期内FeAlOx/MMT缓释出Fe离子并进而由Fe离子催化溶液中的Fenton反应。通过对非均相催化降解苯酚废水的动力学研究发现,H2O2初始浓度、溶液的pH和反应温度对COD降解效率具有显著影响。调节降解过程中的温度序列和氧化剂引入程序能够缓解高温和高双氧水浓度双重因素耦合导致的HO.自消耗。在优化的降解条件下使用理论用量的H2O2可使得1 g/L的苯酚废水中苯酚降解率达到100%,而COD的降解率则达到97%。  相似文献   

20.
Photocatalytic oxidation of gaseous DMF using thin film TiO2 photocatalyst   总被引:2,自引:0,他引:2  
Chang CP  Chen JN  Lu MC  Yang HY 《Chemosphere》2005,58(8):1071-1078
The heterogeneous photocatalytic oxidation of gaseous N,N'-dimethylformamide (DMF) widely used in the manufacture of synthetic leather and synthetic textile was investigated. The experiments were carried out in a plug flow annular photoreactor coated with Degussa P-25 TiO2. The oxidation rate was dependent on DMF concentration, reaction temperature, water vapor, and oxygen content. Photocatalytic deactivation was observed in these reactions. The Levenspiel deactivation kinetic model was used to describe the decay of catalyst activity. Fourier transform infrared (FTIR) was used to characterize the surface and the deactivation mechanism of the photocatalyst. Results revealed that carbonylic acids, aldehydes, amines, carbonate and nitrate were adsorbed on the TiO2 surface during the photocatalytic reaction. The ions, NH4+ and NO3-, causing the deactivation of catalysts were detected on the TiO2 surface. Several treatment processes were applied to find a suitable procedure for the regeneration of catalytic activity. Among these procedures, the best one was found to be the H2O2/UV process.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号