首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

2.
PCDD/F emissions from heavy duty vehicle diesel engines   总被引:1,自引:0,他引:1  
Geueke KJ  Gessner A  Quass U  Bröker G  Hiester E 《Chemosphere》1999,38(12):2791-2806
The currently available information on PCDD/F emissions from diesel vehicles is briefly surveyed. Considerable uncertainty is identified concerning the emissions from heavy duty diesel trucks which have been measured only twice so far. These measurements led to emission factors differing by a factor of 200; similar discrepancy was also revealed by measurements of ambient air in traffic tunnels. New PCDD/F emission measurement results are presented which have been carried out at the exhaust systems of a stationary engine and of a modern heavy duty vehicle engine at transient operation conditions simulated on a test bench. PCDD/F concentrations in the exhaust gases were found to be in the range of control blank samples. Based on the highest concentration observed in the truck engine exhaust (9.7 pg I-TEQ/dry standard m3) a worst case estimate of the annual PCDD/F emission freight from diesel fuel combustion in the European countries of about 30 g I-TEQ/year is calculated. This emission appears to be irrelevant compared to the overall emission rate of more than 6,000 g I-TEQ/year being inventoried recently. Finally the possibilities to link congener/homologue profiles of diesel emission to profiles found in food or human samples are discussed.  相似文献   

3.
This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 degrees C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 microg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 microg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

4.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

5.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

6.
The PCDD/F and PBDD/F pollution in the ambient atmosphere of Shanghai, China   总被引:11,自引:1,他引:10  
Li H  Feng J  Sheng G  Lü S  Fu J  Peng P  Man R 《Chemosphere》2008,70(4):576-583
Rapid economic growth in the last two decades in Shanghai has had a great adverse influence on its air quality. Therefore, the atmospheric pollutants of Shanghai have received much concern. In this study, concentrations of 2,3,7,8-substituted PCDD/Fs and PBDD/Fs congeners were measured in the ambient air of four districts in Shanghai. The mean atmospheric concentrations (TEQs) of total 2,3,7,8-PCDD/Fs and 2,3,7,8-PBDD/Fs were 8031 fg m(-3) (497.1 fg I-TEQ m(-3)) and 1358 fg m(-3) (304.1 fg I-TEQ m(-3)) for Jiading District, 5308 fg m(-3) (289.0 fg I-TEQ m(-3)) and 709 fg m(-3) (146.9 fg I-TEQ m(-3)) for Zhabei District, 4014 fg m(-3) (144.4 fg I-TEQ m(-3)) and 1239 fg m(-3) (256.9 fg I-TEQ m(-3)) for Pudong District, 3348 fg m(-3) (143.2 fg I-TEQ m(-3)) and 699 fg m(-3) (148.4 fg I-TEQ m(-3)) for Huangpu District, respectively. Our results showed that almost all the PCDD/Fs and PBDD/Fs congeners were partitioned into the particulate phase except the lower chlorinated or brominated ones. The logarithm of the gas/particle partitioning coefficient K(p) has good linear correlation with that of the sub-cooled vapor pressure p(L). Concentrations of PCDD/Fs and PBDD/Fs were both positively correlated to elemental carbon in all districts except Pudong District, suggesting elemental carbon could be a good indicator for dioxins' air pollution. It is intensively suggested that more detailed and deeper studies about PBDD/Fs should be carried out due to their relatively high atmospheric concentrations in Shanghai.  相似文献   

7.
Schüler D  Jager J 《Chemosphere》2004,54(1):49-59
Experiments were conducted at the VERONA pilot plant, an incineration plant with stationary grate and separate post-combustion chamber, using wood and propane as basic combustible materials and with controlled dosage of various bromine-, chlorine- and copper-containing compounds. The behaviour of the following compounds was studied in the combustion chamber, after the post-combustion chamber and after the heat exchanger: polychlorinated phenols (PCPh), polybrominated phenols (PBrPh), polychlorinated benzenes (PCBz), polybrominated benzenes (PBrBz), polychlorinated dioxins and furans (PCDD/F) and polybrominated dioxins and furans (PBDD/F). The bromine co-incineration leaded to very high bromophenol concentrations after the post-combustion chamber. The formation of brominated and mixed-halogenated phenols and the further reaction to halogenated dioxins is apparently a relevant reaction mechanism for dioxin formation in processes involving bromine. This assumption is supported by the high formation rates of PBDD/F found in the heat exchanger, which were 4-20 times higher than those of PCDD/F. Moreover, the strong correlations found between the formation rates of PCPh, PCBz and PCDD/F in the heat exchanger indicate that in addition considerable new formation of dioxins takes place through de novo synthesis. Experiments involving the variation of primary operational parameters and fuel properties have shown that the quality of post-combustion plays a much greater role than the other parameters. Furthermore, it became apparent that the congeners of the chlorophenols and of the chlorobenzenes, measured in various incineration stages, do not correlate closely with the dioxin concentrations after the heat exchanger.  相似文献   

8.
The objectives of this work were to study the effect of urea addition to the fuel before the combustion on the suppression of PCDD/F emissions, to examine the influence of urea to PCDD/F isomer patterns by employing statistical analysis techniques and to determine the most effective method of urea addition. Urea in the form of powder and as an aqueous solution was mixed with RDF and the fuel mixtures were incinerated in a lab-scale reactor at 1000 degrees C. PCDD/F emitted during combustion experiments were collected in a quartz wool filter downstream the reactor unit. Analysis and quantification of PCDD/F showed that urea significantly affected PCDD/F emissions. Combustion of RDF containing 10% w/w urea resulted in PCDD/F emissions lower than 8 I-TEQ ng/g RDF, while the corresponding average value from single RDF combustion was 17 I-TEQ ng/g RDF. The PCDD/F prevention capacity of urea was independent from the method of urea addition to the fuel, as similar results were obtained after the addition of urea in the solid and in the aqueous phases. Results assessment by statistical methods showed that isomer patterns remained almost stable and were not affected by the method of urea addition.  相似文献   

9.
Alcock RE  Gemmill R  Jones KC 《Chemosphere》1999,38(4):759-770
PCDD/F data are presented from 75 samples of primary emissions sampled between 1995-97 as part of the compliance monitoring survey undertaken by the UK Environment Agency. Municipal solid waste (MSW), chemical waste and clinical waste incinerators, cement kilns, sinter plants and sewage sludge incinerators were the source categories monitored and reported here. Based on this monitoring programme, the previous national UK emission estimates by Eduljee and Dyke (1) of 560-1100 g I-TEQ a(-1) for 1993 have been revised downwards to 220-660 g I-TEQ a(-1). Despite source reduction measures, MSW incinerators remain a significant source of PCDD/Fs to the atmosphere, contributing between 30-50% of the EPCDD/F I-TEQ emission, rather than the approximately 80% they were estimated to contribute in 1993. 2,3,7,8-substituted PCDD/F congener profile data are presented for some of the source categories and generally support the view that differences in the mixtures ('fingerprints') of PCDD/Fs emitted from different sources are observed. New data on the dioxin-like PCB emissions are presented for cement kilns and sinter plants. These show that TEQ-rated PCBs can make an important contribution to the I-TEQ emitted from certain combustion sources. High concentrations of a full range of PCB congeners/homologues have been measured in the atmosphere close to sintering strands, although the precise source of PCBs from this process remains unclear.  相似文献   

10.
Zhang HJ  Ni YW  Chen JP  Zhang Q 《Chemosphere》2008,70(4):721-730
Optimizing the operating parameters to minimize polychlorodibenzo-p-dioxins and polychlorodibenzofurans (PCDD/F) emission is the common interest of the municipal solid waste (MSW) incineration industry. In this study, we investigated the distribution of tetra- to octa-CDD/F along the flue gas line in a full-scale reciprocating grate incinerator and evaluated the effects of temperature control and O(2) level on PCDD/F formation. Six runs were laid out and all performed under sufficient burning conditions, in which the combustion efficiency of MSW was more than 99.9%. The total concentration of tetra- to octa-CDD/F measured at the boiler outlet showed an increasing tendency with the increase of boiler outlet temperature (T(B)) from 214 degrees C to 264 degrees C. When flue gas ran across the semi-dry scrubber and cyclone precipitator, in which the temperature varied from 264 degrees C to 162 degrees C, the concentrations of the lower chlorinated dioxins and furans were significantly raised, especially for the TCDF. Increasing O(2) supply from 6.0% to 10.5% essentially led to a higher yield of tetra- to octa-PCDD/F, suggested that under sufficient burning conditions the lower O(2) level was favorable for reducing PCDD/F formation and emission. The variation of O(2) level did not give rise to a systematical change of PCDD/F homologue pattern. For all measurements, the isomer distributions of tetra- to hepta-PCDD/F were more or less the same, nearly independent of variations in the operating conditions and sampling positions. Only the significant increase of the sum of 1,3,7,8-TCDF and 1,3,7,9-TCDF was found in the zone after the boiler section.  相似文献   

11.
Fabrellas B  Sanz P  Abad E  Rivera J 《Chemosphere》2001,43(4-7):683-688
The main objectives of the Spanish dioxin inventory and the incidence of municipal waste incinerators in the PCDD/Fs releases in the period from January 1997-November 1999 are presented. Preliminary data about the stack emission levels, fly ashes and slags as solid residues and the PCDD/Fs input in the USW are also presented to elaborate an initial balance for the incineration sector. A great decrease, from 20 to 1.2 g I-TEQ/y, from incineration gas emissions has been observed since 1996. The preliminary balance in the MWI sector suggests an overall PCDD/Fs destruction. The calculated emission factor, 1.06 microg I-TEQ/Mg, indicates a high quality of the air pollution control systems. The assumption of PCDD/Fs in the USW permits an initial evaluation of other waste management systems.  相似文献   

12.
The results of an assessment study of both industrial and non-industrial dioxin and furan (PCDD/Fs) emissions in the Lombardy Region (Italy) are outlined below. The main data source refer to 1997, and are compiled from the Lombardy Emissions Inventory (developed under the framework of the Regional Air Quality Plan) together with documented emissions factors available. Due to the uncertain nature of the emissions assessment, results are provided as a most probable value within a given range. Total PCDD/Fs emissions in Lombardy average 33 g I-TEQ y(-1), ranging from minimum 13 g I-TEQ y(-1) to maximum 88 g I-TEQ y(-1). The main PCDD/Fs sources are waste incineration, electric arc furnace for steel production, vehicle diesel combustion and residential wood combustion. Incineration emission factors are expected to decrease over the period 2005-2010, in compliance with legal requirements. This will prioritize control over the remaining main PCDD/Fs contributors. Due to limited information available concerning this data, the accuracy of which is uncertain, further research is needed to evaluate the future role of these sources.  相似文献   

13.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

14.
Abstract

This study characterized the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from the stack flue gases of 17 industrial sources, which were classified into 10 categories. The results show that the mean PCDD/PCDF concentration of secondary zinc smelter (Zn-S) and secondary copper smelter (Cu-S) is 2.44 ng international toxic equivalent (I-TEQ)/Nm3 (N represents normal conditions at 0 °C, 760 mmHg), which was found to be significantly greater than that of industrial waste incinerators (mean concentration = 0.15 ng I-TEQ/Nm3). These results imply that the controlling of secondary metallurgical melting processes is more important than industrial waste incineration for the reduction of PCDD/PCDF emissions. The mean emission factors of cement production, Zn-S and Cu-S, are 0.052, 1.99, and 1.73 μg I-TEQ/t product, respectively. For industrial waste incineration, the mean emission factors of waste rubber, waste liquor, waste sludge, industrial waste solid (IWI)-1, IWI-2, IWI-3, and IWI-4 are 0.752, 0.435, 0.760, 6.64, 1.67, 2.38, and 0.094 μg I-TEQ/t feed, respectively. Most of the PCDD/PCDF emission factors established in this study are less than those reported in previous studies, which could be because of the more stringent regulations for PCDD/PCDF emissions in recent years.  相似文献   

15.
PCDD/PCDF reduction by the co-combustion process   总被引:1,自引:0,他引:1  
Lee VK  Cheung WH  McKay G 《Chemosphere》2008,70(4):682-688
A novel process, termed the co-combustion process, has been developed and designed to utilise the thermal treatment of municipal solid waste (MSW) in cement clinker production and reduce PCDD/PCDF emissions. To test the conceptual design; detailed engineering design of the process and equipment was performed and a pilot plant was constructed to treat up to 40 tonnes MSW per day. The novel process features included several units external to the main traditional cement rotary kiln: an external calcinations unit in which the hot gas calcined the limestone thus making significant energy savings for this chemical reaction; the lime generated was used in a second chamber to act as a giant acid gas scrubber to remove SOx and particularly HCl (a source of chloride); an external rotary kiln and secondary combustion unit capable of producing a hot gas at 1200 degrees C; a gas cooler to simulate a boiler turbogenerator set for electricity generation; the incorporation of some of the bottom ash, calcined lime and dust collector solids into the cement clinker. A PCDD/PCDF inventory has been completed for the entire process and measured PCDD/PCDF emissions were 0.001 ng I-TEQ/Nm(3) on average which is 1% of the best practical means [Hong Kong Environmental Protection Department, 2001. A guidance note on the best practicable means for incinerators (municipal waste incineration), BPM12/1] MSW incineration emission limit values.  相似文献   

16.
The production of cement in China is accompanied by various emissions, such as fine particulate matter, heavy metals, nitrogen oxides, sulfur oxides, carbon dioxide…. Moreover, cement kiln presents a potential health risk to its surroundings, linking to emissions of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in brief dioxins. Flue gas samples were collected from five typical cement kilns during twelve runs and were used to evaluate the levels and distribution of PCDD/Fs in the emissions from cement kilns. The PCDD/Fs concentrations (136 congeners) and I-TEQ values ranged from 2.3 to >40 ng/m3 and 9.3?~?90.8?×?10?3 ng I-TEQ/m3, respectively, which were lower than the emission standard in China (0.1 ng I-TEQ/m3). In weight units, the dominant congeners were OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF; 2,3,4,7,8-PeCDF is the largest contributor (36–66 %) to the total I-TEQ value of twelve runs. HxCDF and TCDF were the first two most abundant homologue groups (12–85 and 4–52 %), and the homologue concentration decreased with rising chlorine number for PCDDs. In addition, there was no marked difference in homologue profiles when solid wastes (refuse-derived fuel and municipal solid waste) and hazardous wastes (DDT and POPs) were combusted as supplemental fuels. The use of various supplemental fuels had no obvious effect on the fingerprint of PCDD/F homologues. Moreover, there was no significant difference in levels of PCDD/Fs emission due to the diversity of production capacity, which were consistent with reported previously. Air pollution control device had effect on the homologue profiles, and cement system with electrostatic precipitators (ESP) had more fractions of octachloro congeners to the total.  相似文献   

17.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

18.
Urea as a PCDD/F inhibitor in municipal waste incineration   总被引:2,自引:0,他引:2  
Emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from municipal waste incineration have been widely studied because of their extensive toxicity, and many efforts have been made to restrict their emissions. Although a number of chemical compounds have been shown in laboratory-scale tests to inhibit the formation of PCDD/Fs, few have been tested in pilot- or full-scale plants. This work evaluates the effect of urea as a PCDD/F inhibitor in a pilot-scale incinerator that uses refuse-derived fuel (RDF). The decomposition of urea under the test conditions was also studied using detailed kinetic modeling. An aqueous solution of urea was injected into the flue gas stream after the furnace at approximately 730 degrees C, with varied urea concentrations and flue gas residence times used between the furnace and the sampling point. The results demonstrate that urea can successfully inhibit PCDD/F formation in waste incineration if concentrations and injection points are properly adjusted. The kinetic model showed that urea can be rapidly decomposed under appropriate flue gas conditions, indicating that in addition to the urea molecule itself, decomposition products of urea can also be responsible for the reduction of PCDD/F production during incineration.  相似文献   

19.
The present study was intended to establish an inventory of PCDD/F emissions in Tarragona Province (Catalonia, NE Spain), as a preliminary phase in the development of a flow analysis of PCDD/Fs in this Province. In 1999, global PCDD/F emissions reached a value of 2.24 g I-TEQ/y, which means a density of 3.8 micrograms I-TEQ/inhabitant/y. The low amount of PCDD/Fs emitted to air by the only municipal solid waste incinerator in the Province (approximately 0.04% of the total) has been one of the most notable results. As a reflection of uncertainties in the estimates for individual sources, the 90th percentiles of PCDD/F releases for 1999 ranged up to 4.1 g I-TEQ/y.  相似文献   

20.
PCDD/F levels in food and canteen meals from southern Germany   总被引:1,自引:0,他引:1  
Mayer R 《Chemosphere》2001,43(4-7):857-860
Analysis of food samples collected in 1997 and 1998 in Bavaria, Germany showed that PCDD/F levels in food of animal origin, with the exception of fish, have decreased to low levels way below 1 pg I-TEQ/g fat. Lowest PCDD/F contents were found in pork (mean: 0.27 pg I-TEQ/g fat) followed by poultry and cow's milk (mean: approx. 0.5 pg I-TEQ/g fat). Average contamination levels determined in beef and eggs lay in the range from 0.7 to 0.8 pg I-TEQ/g fat. PCDD/F levels in fish were clearly higher than levels in meat, milk and egg samples (mean: 5.6 pg I-TEQ/g fat). Comparison of topical levels with former results from Bavaria show that the recently detected decline of contamination of food has continued during the past few years. In addition to investigations of unprepared food, we analysed prepared canteen meals over a period of 1 year. The average PCDD/F level found in canteen food (0.37 pg I-TEQ/g fat) was in good conformity with determined PCDD/F levels in unprepared food regarding the estimated fat composition of prepared meals. The average consumption of fat per meal via canteen food was 21.1 g and the average PCDD/F intake per meal was 7.6 pg I-TEQ. On the supposition that determined PCDD/F levels in canteen food on fat basis are representative of total fat consumed by humans (102 g fat/day), the daily PCDD/F intake would amount to a mean value of 36.7 pg I-TEQ corresponding to 0.52 pg I-TEQ/kg body weight.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号