首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The development of convenient and competitive devices and methods for monitoring of organic pollutants in the aquatic environment is of increasing interest. An integrative passive sampling system has been developed which consists of a solid poly(dimethylsiloxane) (PDMS) material (tube or rod), acting as hydrophobic organic receiving phase, enclosed in a water-filled or an air-filled low-density polyethylene (LDPE) membrane tubing. These samplers enable the direct analysis of the pollutants accumulated during exposure in the receiving phase by thermodesorption-GC/MS, avoiding expensive sample preparation and cleanups. The capabilities of these sampling devices were studied for the sampling of 20 persistent organic pollutants (chlorobenzenes, hexachlorocyclohexanes, p,p'-DDE, PAHs, and PCBs) in laboratory exposure experiments. For the three sampler designs investigated the uptake of all target analytes was integrative over exposure periods up to 9 days (except PCB 101). The determined sampling rates range from 4 to 1340 microl h(-1) for the water-filled samplers and from 20 to 6360 microl h(-1) for the air-filled ones, respectively. The sampling rate of the analytes is dependent on their molecular weight, partition between water and sampler media (PDMS, polyethylene, water, air) and also of the sampler design. The passive samplers enable the estimation of time-weighted average (TWA) concentration of water pollutants in the lower ng l(-1) to pg l(-1) range.  相似文献   

2.
Two types of passive sampler were developed for the long-term monitoring of semivolatile organic compounds (SOCs) in air. They consist of poly(dimethylsiloxane) (PDMS)-coated stir bars (type A) or silicone tubing (type B), acting as a solid receiving medium, enclosed in a heat-sealed low-density polyethylene (LDPE) membrane. These samplers combine the advantages of integrative passive sampling with those of analysing accumulated analytes by thermodesorption-GC-MS, whilst avoiding the use of solvents and expensive sample preparation and cleanup steps. The performance of these samplers was investigated for the integrative sampling of SOCs, including alpha- and gamma-hexachlorocyclohexanes, hexachlorobenzene, 2,4,4'-trichlorobiphenyl, 2,2',5,5'-tetrachlorobiphenyl and fluoranthene, in laboratory exposure experiments under controlled conditions. For both types of sampler, the uptake of all the analytes investigated was linear over an exposure period of 15 days. The sampling rates calculated ranged from 70 to 320 ml h(-1) (sampler A) and 630 to 4300 ml h(-1) (sampler B). The passive samplers are able to detect low time-weighted average air concentrations in the pg m(-3) range. The small, robust and inexpensive sampling devices were tested successfully for the long-term air monitoring of semivolatile organic pollutants in a polluted area over an exposure period of up to 28 days.  相似文献   

3.
A new sampling system has been developed for the measurement of time-averaged concentrations of organic micropollutants in aquatic environments. The system is based on the diffusion of targeted organic compounds through a rate-limiting membrane and the subsequent accumulation of these species in a bound, hydrophobic, solid-phase material. It provides a novel and robust solution to the problem of monitoring in situations where large temporal fluctuations in pollutant levels may occur. Accumulation rates are regulated by choice of diffusion-limiting membrane and bound solid-phase material and have been found to be dependent on the physico-chemical properties of individual target analytes. Two separate prototype systems are described: one suitable for the sampling of non-polar organic species with log octanol/water partition coefficient (log P) values greater than 4, the other for more polar species with log P values between 2 and 4. Both systems use the same solid-phase material (47 mm C18 Empore disk) as a receiving phase but are fitted with different rate-limiting membrane materials (polysulfone for the polar and polyethylene for the non-polar analytes). The two systems complement each other and together can be used for sampling a wider range of organic analytes than generally possible using current passive sampling techniques. Calibration data are presented for both devices. In each case, linear uptake kinetics were sustained, under constant conditions, for deployment periods of between 1 and 9 days. The effects of water temperature and turbulence on sampling rates have been quantitatively assessed. The performance of the system was further investigated by means of field exposures for one and two weeks in marine environments where calibrated samplers were used to determine the time-averaged concentrations of the polar biocides diuron and irgarol 1051. The quantitative results obtained using the passive sampler were compared with those obtained using spot sampling.  相似文献   

4.
A cellulose acetate membrane, positioned in a passive sampler system, was coated with the perfluorinated polymer Nafion. Aqueous metal transport through the membrane and the Nafion film was investigated. The Nafion-coated membrane prevents the transport of metals bound to natural organic material to the receiving phase in the passive sampler, while copper associated with small synthetic ligands pass through the Nafion film. Increasing thickness of the Nafion film decreases the metal uptake rate to the receiving phase in the passive sampler and increases the response time. A decreased response time for the passive sampler would provide a better estimation of rapid changes in concentration, particularly for dynamic aquatic systems such as urban runoff. Limited biofouling protection with the Nafion coating was demonstrated by growth inhibition of natural periphyton communities on glass surfaces.  相似文献   

5.
A passive sampler has been developed and is demonstrated in situ for urban runoff. The passive sampler is compared to conventional composite (time-dependent and flow-weighted) bottle sampling during and between storm events. The sampling was carried out at established stormwater stations; before and after a stormwater detention pond. In situ deployment of the passive sampler provides the metal concentrations, corresponding to the electrochemically available fraction of total metal, for time-dependent samples collected in parallel. The sampler provides improved accuracy compared to bottle sampling because contamination during sample transport and handling is minimised. Laboratory handling is reduced by direct analysis of the accumulated metals on the receiving membrane by laser ablation inductively coupled plasma mass spectrometry. Passive sampling also solves the problem of metal speciation change during transport to the laboratory, which is a potential problem for bottle samples. The low cost and convenience of the passive sampler and subsequent analysis should allow significantly more extensive spatial and temporal monitoring of metals in the aquatic environment than has previously been possible.  相似文献   

6.
A thin-walled silicone rubber hollow fibre membrane has been developed as a passive sampler. The inside of the tube is filled with an aqueous solution at an appropriate pH. The tube is sealed at both ends and then immersed in a water sample. In order for the ionizable permeating compounds to be trapped in the aqueous receiving phase, the pH is adjusted such that the compounds are ionized and trapped. The major advantages are its simplicity, low cost and high selectivity, since only ionizable organic compounds are trapped. Additionally, the sampler uses no organic solvent. By adjusting the pH of the acceptor phase, it is possible to control the extraction process and whether the sampler is used in the kinetic or equilibrium regime. Since it is very selective, no further clean-up of the extract is required. The membrane assisted passive sampler has been tested for extraction of chlorophenols under laboratory conditions. The extraction process was found to be linear over a 72 h sampling period. Selectivity of the passive sampler in river water was demonstrated and the extraction process was independent of sample concentration, even at lower concentration levels of analytes. However, the sample matrix in some river water samples led to incomplete trapping, thereby reducing the amount trapped in the acceptor phase. Detection limits (three times signal to noise ratio) were dependant on sample matrix and type of detection system and ranged from 0.05 microg L(-1) to about 1 microg L(-1) with a UV photodiode detector in water samples from one river and 1.0 microg L(-1) to 20 microg L(-1) in another but with an ordinary UV detector. The enrichment factors in river water were 28 for 2-chlorophenol and 44 for 2,4-dichlorophenol over a 72 h sampling period. 4-chlorophenol was poorly extracted and its enrichment factor was 3.  相似文献   

7.
基于葫芦脲的超分子特性,以醋酸纤维素为载体,制备了葫芦脲膜,采用傅里叶红外光谱、扫描电镜、热重分析对膜的性能进行了表征,研究了葫芦脲膜对三氯生(TCS)和三氯卡班(TCC)的吸附性能,验证了以葫芦脲膜为结合相的被动采样技术测定2种物质的可行性。结果表明:葫芦脲分子确实被引入到醋酸纤维素中,相比于醋酸纤维素膜,葫芦脲膜具有更强的热稳定性和吸附性能;以葫芦脲膜为结合相的被动采样装置在不同环境因素(pH值、离子强度、可溶性有机质)下都具有良好的工作稳定性;将该装置布设到南京市秦淮河中的2个采样点,野外实验验证了该采样装置应用于监测实际水体中的TCS和TCC的可行性。  相似文献   

8.
Suddenly occurring and time limited chemical exposures caused by unintended incidents might pose a threat to many workers at various work sites. Monitoring of exposure during such occasional incidents is challenging. In this study a compact, low-weight and personal semi-automatic pumped unit for sampling of organic vapor phase compounds from occupational air during sporadic and suddenly occurring incidents has been developed, providing simple activation by the worker potentially subjected to the sudden occurring exposures when a trained occupational hygienist is not available. The sampler encompasses a tube (glass or stainless steel) containing an adsorbent material in combination with a small membrane pump, where the adsorbent is capped at both ends by gas tight solenoid valves. The sampler is operated by a conventional 9 V battery which tolerates long storage time (at least one year), and is activated by pulling a pin followed by automatic operation and subsequent closing of valves, prior to shipping to a laboratory. The adjustable sampling air flow rate and the sampling time are pre-programmed with a standard setting of 200 mL min(-1) and 30 min, respectively. The average airflow in the time interval 25-30 min compared to average airflow in the interval 2-7 min was 92-95% (n = 6), while the flow rate between-assay precisions (RSD) for six different samplers on three days each were in the range 0.5-3.7%. Incident sampler recoveries of VOCs from a generated VOC atmosphere relative to a validated standard method were between 95 and 102% (+/-4-5%). The valves that seal the sampler adsorbent during storage have been shown to prevent an external VOC atmosphere (500 mg m(-3)) to enter the adsorbent tube, in addition to that the sampler adsorbent is storable for at least one month due to absence of ingress of contaminants from internal parts. The sampler was also suitable for trapping of semi-volatile organophosphates.  相似文献   

9.
By using a dynamic dilution system, the atmospheric measurement of 11 selected toxics VOCs (ethylene, acetylene, propene, 1-butene, 1,3-butadiene, 1-pentene, 1-hexene, benzene, toluene, ethylbenzene, m+p-xylene) from the list WHO of 1996 and TO-14 method of US EPA by preconcentration by thermal desorption (TD), analysis by gas chromatography (GC), identification and quantification with a flame ionisation detector (FID) was developed and validated in term of metrology, especially the techniques of sampling of these VOCs with adsorbents cartridges "Air Toxics" when used with an "UMEG sampler" equipped in the inlet with a nafion membrane. In particular the influence of climatic conditions (temperature and relative humidity) and the influence of chemical factors like ozone, on the representativity of sampling were studied. Experiments made with various humidities showed that the addition of a nafion membrane in the inlet of the sampling system was required. Without this membrane, losses of compounds were observed for RH >50%. With this membrane, storage for 2 weeks in a refrigerator, as for canisters, did not induce a loss of compounds. No significative decrease of concentrations of the studied VOCs after 14 days storage, which are known to react with ozone, were observed with an ozone concentrations of 55 ppb. One explanation is that nafion membrane, placed in the inlet of the sampler, will neutralize ozone before entering the sampling tubes. This observation is in accordance with literature which states that the sampling of VOCs on Carbotrap cartridges without ozone scrubber induce a loss of compounds.  相似文献   

10.
Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for monitoring organic contaminants in groundwater was evaluated in a pilot field application in an area severely contaminated by chemical waste, especially by chlorinated hydrocarbons. The spatial distribution of hydrophobic groundwater contaminants was assessed using a combination of passive sampling with SPMDs and non-target semiquantitative GC-MS analysis. More than 100 contaminants were identified and semiquantitatively determined in SPMD samples. Along the 6 field sites under investigation, a large concentration gradient was observed, which confirms a very limited mobility of hydrophobic substances in dissolved form in the aquifer. The in situ extraction potential of the SPMD is limited by groundwater flow, when the exchange volume of well water during an exposure is lower than the SPMD clearance volume for the analytes. This study demonstrates that SPMDs present a useful tool for sampling and analyzing of groundwater polluted with complex mixtures of hydrophobic chemicals and provides guidance for further development of passive sampling technology for groundwater.  相似文献   

11.
负载咪唑型离子液体硅胶吸附材料制备及应用研究   总被引:1,自引:1,他引:0  
制备了3种取代咪唑键合的硅胶负载型离子液体(甲基咪唑-SIL、氨丙基咪唑-SIL及十二烷基咪唑-SIL),比较了其对水中双酚A(BPA)的吸附能力。在该研究的实验条件下,BPA在十二烷基咪唑-SIL与水溶液之间的分配系数Kd值高达(2.58±0.02)×103 L/kg,氨丙基咪唑-SIL、甲基咪唑-SIL的Kd值也分别达到(2.26±0.28)×10、(2.71±0.16)×10 L/kg。采用甲醇为洗脱液,可以对十二烷基咪唑-SIL相中的BPA进行有效回收,2次洗脱的合并回收率为106.7%±4.8%。以十二烷基咪唑-SIL作为被动采样装置的接收相,对污水处理厂出水中BPA进行了被动采样监测应用的微宇宙实验研究。结果表明,在实验周期内,十二烷基咪唑-SIL被动采样器对水体中BPA的被动采集呈线性,其采集速率为0.33 L/d,与以HLB为接收相的商品化被动采样器接近,并且同HLB固相萃取填料相比,离子液体接收相对BPA的采集更具选择性,基质效应较小,可作为被动采样监测装置的理想接收相材料。  相似文献   

12.
The dialdehyde glyoxal (ethanedial) is an increasingly used industrial chemical with potential occupational health risks. This study describes the development of a personal sampling methodology for the determination of glyoxal in workroom air. Among the compounds evaluated as derivatizing agents; N-methyl-4-hydrazino-7-nitrobenzofurazan (MNBDH), 1,2-phenylenediamine (OPDA), 1-dimethylaminonaphthalene-5-sulfonylhydrazine (dansylhydrazine, DNSH) and 2,4-dinitrophenylhydrazine (DNPH), DNPH was the only reagent that was suitable. Several different samplers were evaluated for sampling efficiency of glyoxal in workroom air using DNPH as derivatizing agent; in-house DNPH coated silica particles packed in two different types of glass tubes, impingers containing acidified DNPH solution, filter cassettes containing glass fibre filters coated with DNPH, a commercially available solid phase cartridge sampler originally developed for formaldehyde sampling (Waters Sep-Pak DNPH-silica cartridge), and the commercially available SKC UMEx 100 passive sampler originally developed for formaldehyde sampling. Aldehyde atmospheres for sampler evaluation were generated with an in-house made vapour atmosphere generator coupled to a sampling unit, with the possibility of parallel sampling. The resulting glyoxal-DNPH derivative was determined using both LC-UV and LC-APCI-MS with negative ionization. By far, the highest recovery of glyoxal was obtained employing one of the in-house DNPH coated silica samplers (93%, RSD = 3.6%, n = 12).  相似文献   

13.
A resampling technique (bootstrapping) was used to evaluate the effects of increasing sample number on the confidence limits of mean density and the mean number of taxa (Families) in addition to the performance of four different sampling devices used to collect macroinvertebrates in three streams of contrasting anthropogenic impact. The four sampling devices were a Hess sampler, a modified Hess sampler equipped with an internal water pump, a Surber sampler, and a two-pole kick-net. In general, confidence limits decreased predictably as the number of samples increased, most notably with the addition of a third sample. The density of organisms captured with the Surber sampler was significantly lower than that of the Hess sampler but greater than that of the kick-net sampler. No significant difference in the number of Families was found among sampling devices. Based upon a minimal 10% reduction in confidence limits compared to the previous sample, a minimum of four replicates was suggested when using the Surber sampler. In general, other methods required a greater number of replicates that the Surber to adequately represent density, but this did not hold when applied to the number of taxa. Despite the inconvenience of having to bend down to use the Surber sampler, this study found no evidence to reject its apparent popularity as a sampling method for macroinvertebrates.  相似文献   

14.
A diffusive sampling method for determination of methyl isocyanate in air has been developed. A glass fibre filter impregnated with 1-(2-methoxyphenyl)piperazine in a commercially available diffusive sampling device was used to collect methyl isocyanate and the derivative formed was analysed with LC-MS/MS. The sampling rate was determined to be 15.6 ml min(-1), with a relative standard deviation of 7.3%. The sampler was validated for sampling periods from 15 min to 8 h, for relative humidities from 20% to 80% and for concentrations from I to 46 microg m(-3). A field validation was also made and the diffusive sampling results showed no difference compared to a pumped reference method. The impregnated filters have to be stored apart from the diffusive sampler housing and loaded into the sampler prior to each sampling.  相似文献   

15.
总结了半透膜被动采样器(SPMDs)、极性有机化合物整合采样器(POCIS)、化学捕收器(Chemcatcher)和硅橡胶被动采样器(Silicon rubber)几种常用被动采样器的结构组成、应用模型、原理、样品的前处理、影响因素及应用范围,指出几种被动采样技术应用上存在的问题,并对其应用前景进行总结和展望。  相似文献   

16.
A diffusive sampler for NO2, Willems badge, was validated in laboratory experiments and field tests. The collecting reagent for NO2 in the sampler is triethanolamine, and the analysis is based on a modified colorimetric method, the Saltzman method. The analysis was performed by a flow injection analysis (FIA) technique. The sampling rate for the sampler was determined to be 40.0 ml min-1. There was no effect of NO2 concentration or relative humidity on sampling rate, and the influence of sampling time was found to be small. The detection limit was 4 micrograms m-3 for a 24 h sample. The capacity is high enough to allow sampling of 150 micrograms m-3 for 7 days, which is twice the recommended Swedish short-term (24 h) guideline value as a 98-percentile over 6 months. In field tests, the sampler performed well, even at wind speeds higher than 2 m s-1, and at low temperatures. The overall uncertainty of the method was 24%. The sensitivity and capacity of the method also make it suitable for personal sampling for 2-8 h in working environments.  相似文献   

17.
The solvent-free sampler for airborne isocyanates consisted of a polypropylene tube with an inner wall coated with a glass fibre filter, coupled in series with a 13 mm glass fibre filter. The filters were impregnated with reagent solution containing equimolar amounts of di-n-butylamine (DBA) and acetic acid. Air sampling was performed with an air flow of 0.2 l min(-1). The formed isocyanate-DBA derivatives were determined using liquid chromatography and tandem mass spectrometry. The sampler was investigated in regard to collection principle and extraction of the formed derivatives with good results. The possibility to store the sampler before sampling and to perform long-term sampling was demonstrated. Field extraction of the sampler was not necessary, as there was no difference between immediately extracted samples and stored ones (2 days). In comparative studies, the sampler was evaluated against a reference method, impinger-filter sampling with DBA as reagent. The ratios between the results obtained with the sampler and the reference in a test chamber at a relative humidity (RH) of 45% was in the range of 83-109% for isocyanates formed during thermal decomposition of PUR. At RH 95%, the range was 72-101% with the exception of isocyanic acid. In two field evaluations, the ratios for fast curing 2,4'- and 4,4'-methylene bisphenyl diisocyanate (MDI) was in the range 81-113% and for the 3-ring MDI the range was 54-70%. For the slower curing 1,6-hexamethylene diisocyanate (HDI) and HDI isocyanurate, the ratios were in the range 78-145%. In conclusion, the solvent-free sampler is a convenient alternative in most applications to the more cumbersome impinger-filter sampler.  相似文献   

18.
A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.  相似文献   

19.
On February 26, 1988, the U.S. Environmental Protection Agency promulgated Standards of Performance for residential wood heaters, or woodstoves. Over the past several years, a number of field studies have been undertaken to determine the actual level of emission reduction achieved by new technology woodstoves in everyday use. These studies have required the development and use of particulate and gaseous emission sampling equipment compatible with operation in private houses. Since woodstoves are tested for certification in the laboratory using EPA Methods 5G and 5H, it is of substantial interest to determine the correlation between these regulatory methods and the in-house equipment. Two in-house sampling systems have been used most widely. One is an intermittent, pump-driven particulate sampler which collects particulate and condensable organics on a filter and organic adsorbent resin. Oxygen concentration is measured by a sensor in the sample line. The sampler is controlled by a data logger which also records other parameters of interest. The second system uses an evacuated cylinder as the motive force. Particulate and condensable organics are collected in a condenser and dual filter. The sampler operates continuously whenever the stack temperature is above the set point. Average stack gas concentrations are measured from the evacuated cylinder at the conclusion of the sampling period. Both samplers were designed to operate unattended for 1-week periods. A large number of tests have been run comparing Methods 5G and 5H to both of the field samplers. This paper presents these comparison data and determines the relationships between laboratory certification sampling methods and field samplers.  相似文献   

20.
一种淡水大型底栖无脊椎动物采样器研究   总被引:2,自引:2,他引:0  
研制出一种长方体的十字筐采样器,在采样器内分别填装石、砂、底泥和水草4种基质,利用大型底栖无脊椎动物对生境的选择性进行样本被动采集。基质越多,采样器采集的生物种类越多,生物量也更丰富。用新研制的十字筐采样器和传统的篮式采样器对松花江流域7个采样点进行大型底栖无脊椎动物对比采样,结果显示:十字筐采样器是一种优良的采样器,适合在松花江流域乃至全国推广应用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号