首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
为研究玉米淀粉粉尘爆炸危险性,采用哈特曼管式爆炸测试装置和20 L球爆炸测试装置对200目(<75μm)以下的玉米淀粉粉尘爆炸危险性进行评估,基于静电火花和粉尘质量浓度对粉尘爆炸的影响,对玉米淀粉的静电火花最小点火能量、爆炸下限质量浓度、最大爆炸压力和爆炸指数进行了研究,根据试验结果对玉米淀粉爆炸危险性进行分级。试验结果表明:温度在25℃,喷粉压力为0.80 MPa,粉尘质量浓度在250~750 g/m3范围内,粉尘的最小点火能量随着粉尘质量浓度增加而降低,其最小点火能量在40~80 mJ之间;在点火能量为10 kJ时,粉尘爆炸下限质量浓度在50~60 g/m3之间;在粉尘质量浓度为750 g/m3时,爆炸压力达到最大,为0.66 MPa;在粉尘质量浓度为500 g/m3时,爆炸指数达到最大,为17.21 MPa.m/s,其粉尘爆炸危险性分级为Ⅰ级。  相似文献   

2.
In order to study the influences of coal dust components on the explosibility of hybrid mixture of methane and coal dust, four kinds of coal dust with different components were selected in this study. Using the standard 20 L sphere, the maximum explosion pressure, explosion index and lower explosion limits of methane/coal dust mixtures were measured. The results show that the addition of methane to different kinds of coal dust can all clearly increase their maximum explosion pressure and explosion index and decrease their minimum explosion concentration. However, the increase in the maximum explosion pressure and explosion index is more significant for coal dust with lower volatile content, while the decrease in the minimum explosion concentration is more significant for coal dust with higher volatile content. It is concluded that the influence of methane on the explosion severity is more pronounced for coal dust with lower volatile content, but on ignition sensitivity it is more pronounced for coal dust with higher volatile content. Bartknecht model for predicting the lower explosion limits of methane/coal dust mixture has better applicability than Le Chatelier model and Jiang model. Especially, it is more suitable for hybrid mixtures of methane and high volatile coal dust.  相似文献   

3.
A correlation of the lower flammability limit for hybrid mixtures was recently proposed by us. The experimental conditions including ignition energy and turbulence which play a primary role in a gas or dust explosion were at fixed values. The sensitivity of such experimental conditions to the accuracy of the proposed formula was not thoroughly discussed in the previous work. Therefore, this work studied the effect of varying the ignition energy and turbulence intensity to the formula proposed in our previous paper. For ignition energy effect, results from methane/niacin mixture demonstrated that the MEC and LFL will not be affected by changing ignition energy. There is no distinguishable difference among gas explosion index (KG) and dust explosion index (KSt) derived from tests with every ignition energy (2.5 kJ, 5 kJ and 10 kJ) in a 36 L vessel. The proposed formula is independent of ignition energy. For turbulence effect, the proposed formula can have a good prediction of the explosion and non-explosion zone if the ignition delay time is within a certain range. The formula prediction is good as the ignition delay time increases up to 100 ms in this work. Propane/niacin and propane/cornstarch mixtures are also tested to validate the proposed formula. It has been confirmed that the proposed formula predicts the explosion and non-explosion zone boundary of such mixtures.  相似文献   

4.
在20 L爆炸实验装置中,开展了3种不同中值粒径的EVA树脂粉尘/甲烷/空气所组成的杂混物爆炸特性研究,探究了甲烷浓度对粉尘爆炸下限、最大爆炸压力的影响。结果表明,尽管添加的甲烷气体浓度低于爆炸下限,仍使得粉尘爆炸下限得以降低,粒径较大的EVA III粉尘,当甲烷体积分数为1%时,爆炸下限降低约25%;粒径较小的EVA I粉尘,当混入甲烷体积分数为4%时,爆炸下限则降低80%;甲烷体积分数每增加1%,可燃粉尘最大爆炸压力上升约10%,但对于粒径较小的EVA I粉尘,当甲烷体积分数为4%时,最大爆炸压力的上升呈现突变趋势,上升近50%。  相似文献   

5.
To evaluate the hazard of combined hydrogen/dust explosions under severe accident conditions in International Thermonuclear Experimental Reactor (ITER), standard method of 20-L-sphere was used to measure the explosion indices of 4-μm fine graphite dust in lean hydrogen/air mixtures. The mixtures were ignited by a weak electric spark. The tested fuel concentrations were 8–18 vol% H2 and 25–250 g/m3 dust. If the hydrogen content is higher than 10 vol%, the dust constituent can be induced to explode by the hydrogen explosion initiated by a weak electric spark. Depending on the fuel component concentrations, the explosions proceed in either one or two stages. In two-stage explosions occurring at low hydrogen and dust concentrations, the mixture ignition initiates first a fast hydrogen explosion followed by a slower phase of the dust explosion. With increasing dust concentration, the dust explodes faster and can overlap the hydrogen-explosion stage. At higher hydrogen concentrations, the hybrid mixtures explode in one stage, with hydrogen and dust reacting at the same time scale. Maximum overpressures of hybrid explosions are higher than those observed with hydrogen alone; maximum rates of pressure rise are lower in two-phase explosions and, generally, higher in one-stage explosions, than those characteristic of the corresponding H2/air mixtures.  相似文献   

6.
This paper presents data on the limiting (minimum) concentrations of hydrogen in oxygen, in the presence of added helium, at elevated temperature and pressure related to the practical operational case. A 5 L explosion vessel, an ignition sub-system and a transient pressure measurement sub-system were used. Through a series of experiments carried out using this system, the limiting concentrations of hydrogen in oxygen and helium at different initial pressures and temperatures for the practical operational case were studied, and the influence of ignition energy and initial temperature on the limiting concentration of hydrogen in oxygen and helium was analyzed and discussed. The variation of ignition energy within the studied range is found to have a significant effect on the limiting concentration of hydrogen in oxygen and helium at lower initial temperature. However, when the ignition energy is higher than 32 mJ, the limiting hydrogen concentration remains almost changeless as the initial temperature increases from 21 °C to 90 °C. The limiting explosible concentration of hydrogen–oxygen–helium mixture decreases as the ignition energy increases when the initial temperature is lower. When the initial temperature is higher, the ignition energy has little effect on the limiting hydrogen concentration of hydrogen–oxygen–helium mixtures. When the initial temperature reaches 90 °C, the limiting hydrogen concentration remains almost changeless with an increase in ignition energy. The limiting explosible concentration of hydrogen in the mixtures, at the initial temperature of 21 °C and the ignition energy of 0.5 mJ, is 8.5% and that of oxygen is 11.25%.  相似文献   

7.
Deflagration explosions of coal dust clouds and flammable gases are a major safety concern in coal mining industry. Accidental fire and explosion caused by coal dust cloud can impose substantial losses and damages to people and properties in underground coal mines. Hybrid mixtures of methane and coal dust have the potential to reduce the minimum activation energy of a combustion reaction. In this study the Minimum Explosion Concentration (MEC), Over Pressure Rise (OPR), deflagration index for gas and dust hybrid mixtures (Kst) and explosive region of hybrid fuel mixtures present in Ventilation Air Methane (VAM) were investigated. Experiments were carried out according to the ASTM E1226-12 guideline utilising a 20 L spherical shape apparatus specifically designed for this purpose.Resultsobtained from this study have shown that the presence of methane significantly affects explosion characteristics of coal dust clouds. Dilute concentrations of methane, 0.75–1.25%, resulted in coal dust clouds OPR increasing from 0.3 bar to 2.2 bar and boosting the Kst value from 10 bar m s−1 to 25 bar m s−1. The explosion characteristics were also affected by the ignitors’ energy; for instance, for a coal dust cloud concentration of 50 g m−3 the OPR recorded was 0.09 bar when a 1 kJ chemical ignitor was used, while, 0.75 bar (OPR) was recorded when a 10 kJ chemical ignitor was used.For the first time, new explosion regions were identified for diluted methane-coal dust cloud mixtures when using 1, 5 and 10 kJ ignitors. Finally, the Le-Chatelier mixing rule was modified to predict the lower explosion limit of methane-coal dust cloud hybrid mixtures considering the energy of the ignitors.  相似文献   

8.
The explosion behaviour of heterogeneous/homogeneous fuel-air (hybrid) mixtures is here analysed and compared to the explosion features of heterogeneous fuel-air and homogeneous fuel-air mixtures separately.Experiments are performed to measure the pressure history, deflagration index and flammability limits of nicotinic acid/acetone-air mixtures in a standard 20 L Siwek bomb adapted to vapour-air mixtures. Literature data are also used for comparison.The explosion tests performed on gas-air mixtures in the same conditions as explosion tests of dust-air mixtures, show that the increase in explosion severity of dust/gas-air mixtures has to be addressed to the role of initial level of turbulence prior to ignition.At a fixed value of the equivalence ratio, by substituting the dust to the flammable gas in a dust/gas-air mixture the explosion severity decreases. Furthermore, the most severe conditions of dust-gas/air mixtures is found during explosion of gas-air mixture at stoichiometric concentration.  相似文献   

9.
为测定ABC干粉对瓦斯爆炸的抑制作用,采用容积为20L的近球形抑爆实验系统,粒径为20.76μm,主要成分为高聚合度磷酸铵盐的ABC干粉进行瓦斯抑爆实验。实验结果表明:ABC干粉的添加能够降低瓦斯爆炸的压力;粉体浓度为0.10g/L时,抑爆效果最好;粉体的抑爆效果,不仅与粉体浓度有关,还与爆炸性混合气体中的甲烷浓度有关;点火延迟时间越长,粉体抑爆效果越差。  相似文献   

10.
为研究半开敞空间内可燃气体爆炸过程,设计带有泄压面的气体爆炸室,并在此基础上构建一套可燃气体燃爆特性综合试验装置。运用该试验装置,研究预混塔内甲烷气体分层现象以及甲烷爆炸浓度与最小点火能之间的变化规律。甲烷分层试验结果表明:静置一段时间后,预混塔中甲烷浓度随高度的增加而增大。最小点火能试验结果显示,当甲烷的试验爆炸体积分数在10%~13%时,其浓度与点火能之间呈现比较平缓的变化关系,而当其体积分数小于10%或大于13%时,浓度稍微变化,其点火能将发生明显变化。  相似文献   

11.
Explosibility studies of hybrid methane/air/cork dust mixtures were carried out in a near-spherical 22.7 L explosibility test chamber, using 2500 J pyrotechnic ignitors. The suspension dust burned as methane/air/dust clouds and the uniformity of the cork dust dispersion inside the chamber was evaluated through optical dust probes and during the explosion the pressure and the temperature evolution inside the reactor were measured. Tested dust particles had mass median diameter of 71.3 μm and the covered dust cloud concentration was up to 550 g/m3. Measured explosions parameters included minimum explosion concentration, maximum explosion pressures and maximum rate of pressure rise. The cork dust explosion behavior in hybrid methane/air mixtures was studied for atmospheres with 1.98 and 3.5% (v/v) of methane. The effect of methane content on the explosions characteristic parameters was evaluated. The conclusion is that the risk and explosion danger rises with the increase of methane concentration characterized by the reduction of the minimum dust explosion concentration, as methane content increases in the atmosphere. The maximum explosion pressure is not very much sensitive to the methane content and only for the system with 3.5% (v/v) of methane it was observed an increase of maximum rate of pressure rise, when compared with the value obtained for the air/dust system.  相似文献   

12.
The paper outlines an experimental study on influence of the spark duration and the vessel volume on explosion parameters of premixed methane–air mixtures in the closed explosion vessels. The main findings from these experiments are: For the weaker ignition the spark durations in the range from 6.5 μs to 40.6 μs had little impact on explosion parameters for premixed methane–air mixtures in the 5 L vessel or 20 L vessel; For the same ignitions and volume fractions of methane in air the explosion pressures and the flame temperatures in both vessels of 5 L and 20 L were approximately the same, but the rates of pressure rises in both vessels of 5 L and 20 L were different; The explosion indexes obtained from the measured pressure time histories for both vessels of 5 L and 20 L were approximately equal; For the weaker ignition with the fixed spark duration 45 μs the ignition energies in the range from 54 mJ to 430 mJ had little impact on the explosion parameters; For the same ignition and the volume fractions of methane in air, the vessel volumes had a significant impact on the flame temperatures near the vessel wall; The flame temperatures near the vessel wall decreased as the vessel volumes increased.  相似文献   

13.
With the terms “complex hybrid mixtures”, we mean mixtures made of two or more combustible dusts mixed with flammable gas or vapors in air (or another comburent).In this work, the flammability and explosion behavior of selected complex hybrid mixtures was studied. In particular, we investigated mixtures of nicotinic acid, lycopodium and methane. We performed explosion tests in the 20-L explosion vessel at different overall (nicotinic plus lycopodium) dust concentrations, nicotinic acid/lycopodium ratios, and methane concentrations.An exceptional behavior (in terms of unexpected values of rate of pressure rise and pressure) was found for the complex hybrid mixtures containing lycopodium and nicotinic acid in equal amounts. This mixture was found to be much more reactive than all the other dust mixtures, whatever the dust concentration and the methane content.  相似文献   

14.
The modern world depends greatly on hydrocarbons, which are ubiquitous, indispensable fuels used in nearly every existing industry. Although important, their use may trigger dangerous incidents, whether in their production, handling, storage, or transporting phase, especially when aerosolized. In light of proposing a standard procedure to assess the flammability and explosivity of fuel mists, a new test method was established based on the EN 14034 standards series. For the previous purposes, a gravity-fed mist generation system was designed and employed in a modified 20 L explosion vessel. This test method allowed the determination of the ignition sensitivity of several fuels. In addition, their explosion severity was represented by the explosion overpressure Pex, and the rate of pressure rise dP/dtex, two thermo-kinetic parameters determined with a specifically developed control system and custom software. Nonetheless, a noticeable difference in the ignition sensitivity and the explosion severity was perceived when changing suppliers or petroleum cuts of some fuels. Moreover, sensitivity studies showed that both the droplet size distribution and the temperature of the droplets play a significant role in fuel mist explosion. These parameters can be directly related to the vapor fraction surrounding a droplet during its ignition. Consequently, this study focuses on the influence of varying the composition of three well-known and abundantly used fuels. Different petroleum cuts were introduced in different fractions into isooctane, Jet A1 aviation fuel, and diesel fuel mixtures, which were then aerosolized into a uniformly distributed turbulent mist cloud and ignited using spark ignitors of 100 J. Subsequently, complementary tests were executed in a vertical flame propagation tube coupled with a high-speed video camera allowing the visualization of the flame and the determination of the spatial flame velocity, and a tentative estimation of the laminar burning velocity. The latter was also estimated from the pressure-time evolution in the 20 L sphere using existing correlations. Indeed, the determination of the laminar burning velocity can be useful in modeling such accidents. Finally, highlighting the essential role of the mist and vapor fraction during their ignition has led to a better understanding of their explosion mechanisms.  相似文献   

15.
Dust explosion venting experiments were performed using a 20-L spherical chamber at elevated static activation overpressures larger than 1 bar. Lycopodium dust samples with mean diameter of 70 μm and electric igniters with 0.5 KJ ignition energy were used in the experiments. Explosion overpressures in the chamber and flame appearances near the vent were recorded simultaneously. The results indicated that the flame appeared as the under-expanded free jet with shock diamonds, when the overpressure in the chamber was larger than the critical pressure during the venting process. The flame appeared as the normal constant-pressure combustion when the pressure venting process finished. Three types of venting processes were concluded in the experiments: no secondary flame and no secondary explosion, secondary flame, secondary explosion. The occurrence of the secondary explosions near the vent was related to the vent diameter and the static activation overpressure. Larger diameters and lower static activation overpressures were beneficial to the occurrence of the secondary explosions. In current experiments, the secondary explosions only occurred at the following combinations of the vent diameter and the static activation overpressure: 40 mm and 1.2 bar, 60 mm and 1.2 bar, 60 mm and 1.8 bar.  相似文献   

16.
采用哈特曼管式爆炸测试装置和20L球爆炸测试装置对小麦淀粉粉尘爆炸特性参数进行评估,对粒度小于75μm的样品的爆炸危险性参数进行测试,得出了一定条件下的小麦淀粉对静电火花的敏感程度以及其爆炸的猛烈程度,进而对其爆炸危险性程度进行分级。结果表明,温度在25℃,喷粉压力为0.70MPa,小麦淀粉的最小点火能量在40~80mJ;在点火能量为10 kJ时,最大爆炸压力为0.60MPa,最大爆炸指数为7.87MPa.m/s,其粉尘爆炸危险性为Ⅰ级。  相似文献   

17.
点火位置对独头巷道中瓦斯爆炸超压的影响   总被引:7,自引:0,他引:7  
运用AutoReaGas爆炸仿真模拟器研究了独头巷道中点火位置对瓦斯爆炸后果的影响。结果表明,在本计算条件下,爆炸静态超压随着距离的增加而减小,爆炸动压随着距离的增大而增大,点火位置对爆炸后果有重要影响,点火位置离封闭端越近,各个测点上所得到的超压越大。  相似文献   

18.
Two types of flammability limits have been measured for various dusts in the Fike 1-m3 (1000-L) chamber and in the Pittsburgh Research Laboratory (PRL) 20-L chamber. The first limit is the minimum explosible concentration (MEC), which was measured at several ignition energies. In addition to the three dusts studied previously (bituminous coal, anthracite coal, and gilsonite), this work continues the effort by adding three additional dusts: RoRo93, lycopodium, and iron powder. These materials were chosen to extend the testing to non-coal materials as well as to a metallic dust. The new MEC data corroborate the previous observations that very strong ignitors can overdrive the ignition in the smaller 20-L chamber. Recommendations are given in regard to appropriate ignition energies to be used in the two chambers. The study also considered the other limiting component, oxygen. Limiting oxygen concentration (LOC) testing was performed in the same 20-L and 1-m3 vessels for gilsonite, bituminous coal, RoRo93, and aluminum dusts. The objective was to establish the protocol for testing at different volumes. A limited investigation was made into overdriving in the 20-L vessel. The LOC results tended to show slightly lower results for the smaller test volume. The results indicated that overdriving could occur and that ignition energies of 2.5 kJ in the 20-L vessel would yield comparable results to those in the 1-m3 vessel using 10.0 kJ. The studies also illustrate the importance of dust concentration on LOC determinations.  相似文献   

19.
为探究面粉爆炸实验中粉尘质量浓度、点火能量、点火延迟时间对面粉爆炸的影响,采用正交实验法并利用20 L球形爆炸测试装置比较研究了粉尘质量浓度、点火延迟时间以及点火能对面粉爆炸的影响程度.结果表明:对最大爆炸压力影响最为显著的因素是点火延迟时间,对最大爆炸指数影响最为显著的因素是粉尘质量浓度;在实验浓度范围内,存在最佳实...  相似文献   

20.
Hybrid mixtures – mixtures of burnable dusts and burnable gases – pose special problems to industries, as their combined Lower Explosion Limit (LEL) can lie below the LEL of the single substances. Different mathematical relations have been proposed by various authors in literature to predict the Lower Explosion Limit of hybrid mixtures (LELhybrid). The aim of this work is to prove the validity or limitations of these formulas for various combinations of dusts and gases. The experiments were executed in a standard 20 L vessel apparatus used for dust explosion testing. Permanent spark with an ignition energy of 10 J was used as ignition source. The results obtained so far show that, there are some combinations of dust and gas where the proposed mathematical formulas to predict the lower explosible limits of hybrid mixtures are not safe enough.  相似文献   