首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

Supply curves were prepared for coal-fired power plants in the contiguous United States switching to Wyoming's Powder River Basin (PRB) low-sulfur coal. Up to 625 plants, representing ~44% of the nameplate capacity of all coal-fired plants, could switch. If all switched, more than $8.8 billion additional capital would be required and the cost of electricity would increase by up to $5.9 billion per year, depending on levels of plant derating. Coal switching would result in sulfur dioxide (SO2) emissions reduction of 4.5 million t/yr. Increase in cost of electricity would be in the range of 0.31-0.73 cents per kilowatt-hour. Average cost of S emissions reduction could be as high as $1298 per t of SO2. Up to 367 plants, or 59% of selected plants with 32% of 44% nameplate capacity, could have marginal cost in excess of $1000 per t of SO2. Up to 73 plants would appear to benefit from both a lowering of the annual cost and a lowering of SO2 emissions by switching to the PRB coal.  相似文献   

2.
Environmental and economic evaluation of bioenergy in Ontario, Canada   总被引:1,自引:0,他引:1  
We examined life cycle environmental and economic implications of two near-term scenarios for converting cellulosic biomass to energy, generating electricity from cofiring biomass in existing coal power plants, and producing ethanol from biomass in stand-alone facilities in Ontario, Canada. The study inventories near-term biomass supply in the province, quantifies environmental metrics associated with the use of agricultural residues for producing electricity and ethanol, determines the incremental costs of switching from fossil fuels to biomass, and compares the cost-effectiveness of greenhouse gas (GHG) and air pollutant emissions abatement achieved through the use of the bioenergy. Implementing a biomass cofiring rate of 10% in existing coal-fired power plants would reduce annual GHG emissions by 2.3 million metric tons (t) of CO2 equivalent (7% of the province's coal power plant emissions). The substitution of gasoline with ethanol/gasoline blends would reduce annual provincial lightduty vehicle fleet emissions between 1.3 and 2.5 million t of CO2 equivalent (3.5-7% of fleet emissions). If biomass sources other than agricultural residues were used, additional emissions reductions could be realized. At current crude oil prices ($70/barrel) and levels of technology development of the bioenergy alternatives, the biomass electricity cofiring scenario analyzed is more cost-effective for mitigating GHG emissions ($22/t of CO2 equivalent for a 10% cofiring rate) than the stand-alone ethanol production scenario ($92/t of CO2 equivalent). The economics of biomass cofiring benefits from existing capital, whereas the cellulosic ethanol scenario does not. Notwithstanding this result, there are several factors that increase the attractiveness of ethanol. These include uncertainty in crude oil prices, potential for marked improvements in cellulosic ethanol technology and economics, the province's commitment to 5% ethanol content in gasoline, the possibility of ethanol production benefiting from existing capital, and there being few alternatives for moderate-to-large-scale GHG emissions reductions in the transportation sector.  相似文献   

3.
Atmospheric mercury (Hg) emission from coal is one of the primary sources of anthropogenic discharge and pollution. China is one of the few countries in the world whose coal consumption constitutes about 70% of total primary energy, and over half of coals are burned directly for electricity generation. Atmospheric emissions of Hg and its speciation from coal-fired power plants are of great concern owing to their negative impacts on regional human health and ecosystem risks, as well as long-distance transport. In this paper, recent trends of atmospheric Hg emissions and its species split from coal-fired power plants in China during the period of 2000-2007 are evaluated, by integrating each plant's coal consumption and emission factors, which are classified by different subcategories of boilers, particulate matter (PM) and sulfur dioxide (SO2) control devices. Our results show that the total Hg emissions from coal-fired power plants have begun to decrease from the peak value of 139.19 t in 2005 to 134.55 t in 2007, though coal consumption growing steadily from 1213.8 to 1532.4 Mt, which can be mainly attributed to the co-benefit Hg reduction by electrostatic precipitators/fabric filters (ESPs/FFs) and wet flue gas desulfurization (WFGD), especially the sharp growth in installation of WFGD both in the new and existing power plants since 2005. In the coming 12th five-year-plan, more and more plants will be mandated to install De-NO(x) (nitrogen oxides) systems (mainly selective catalytic reduction [SCR] and selective noncatalytic reduction [SNCR]) for minimizing NO(x) emission, thus the specific Hg emission rate per ton of coal will decline further owing to the much higher co-benefit removal efficiency by the combination of SCR + ESPs/FFs + WFGD systems. Consequently, SCR + ESPs/FFs + WFGD configuration will be the main path to abate Hg discharge from coal-fired power plants in China in the near future. However advanced specific Hg removal technologies are necessary for further reduction of elemental Hg discharge in the long-term.  相似文献   

4.
A computer program has been written to determine the cost of building and operating wet scrubbers on individual coal fired utilities in the states where emissions are likely to affect the acid rain problem in the eastern United States. The program differs from many other estimates since it calculates the cost for each of 831 individual sites. The capital costs for installing scrubbers on the top fifty sulfur oxide emitting plants will be about $20 billion. This will result in an increase in the cost of electricity on an average of 0.88 cents/kWh and a reduction of sulfur oxide emissions from 1980 of 7,100,000 tons per year. An additional reduction of at least 1,000,000 tons per year can be obtained by requiring all plants burning oil to burn low sulfur oil. These figures assume utilities will use least emissions dispatching and will use local coals containing at least 3.5 percent sulfur. The use of local coals should result in a further saving of at least 0.2 cents/kWh. This should make available a large supply of low sulfur coal which could reduce emissions of sulfur oxides by up to 1,000,000 tons per year. The SO2 reductions will be continued for at least the next thirteen years and have a very significant effect through the year 2010.  相似文献   

5.
During wintertime, haze episodes occur in the Dallas-Ft. Worth (DFW) urban area. Such episodes are characterized by substantial light scattering by particles and relatively low absorption, leading to so-called "white haze." The objective of this work was to assess whether reductions in the emissions of SO2 from specific coal-fired power plants located over 100 km from DFW could lead to a discernible change in the DFW white haze. To that end, the transport, dispersion, deposition, and chemistry of the plume of a major power plant were simulated using a reactive plume model (ROME). The realism of the plume model simulations was tested by comparing model calculations of plume concentrations with aircraft data of SF6 tracer concentrations and ozone concentrations. A second-order closure dispersion algorithm was shown to perform better than a first-order closure algorithm and the empirical Pasquill-Gifford-Turner algorithm. For plume impact assessment, three actual scenarios were simulated, two with clear-sky conditions and one with the presence of fog prior to the haze. The largest amount of sulfate formation was obtained for the fog episode. Therefore, a hypothetical scenario was constructed using the meteorological conditions of the fog episode with input data values adjusted to be more conducive to sulfate formation. The results of the simulations suggest that reductions in the power plant emissions lead to less than proportional reductions in sulfate concentrations in DFW for the fog scenario. Calculations of the associated effects on light scattering using Mie theory suggest that reduction in total (plume + ambient) light extinction of less than 13% would be obtained with a 44% reduction in emissions of SO2 from the modeled power plant.  相似文献   

6.
Small concentrations, approximately 2-10 parts per million (ppm), of injected sulfur trioxide (SO3) have improved particulate collection efficiencies of electrostatic precipitators burning lower-sulfur coal. However, the addition of extra SO3 not only incurs costs but also presents negative environmental effects. This work explored a method that could be applied to existing coal-fired power plants to convert the sulfur dioxide (SO2) already present in the flue gas to sufficient levels of SO3 for fly ash conditioning as an alternative to adding SO3 by burning elemental sulfur. During this research, a pre-mixed natural gas flame was used to promote the conversion of SO2 to SO3 in a drop-tube furnace with average non-flame, free stream gas temperatures of 450 and 1000 K. SO3 concentrations measured by wet chemistry and confirmed using elemental balances of other sulfur species measured by gas chromatography revealed that as much as 7% of SO2 was homogeneously transformed to SO3. The results also showed that at low temperatures, the rate at which SO3 is converted back to SO2 decreased, thus extending the time period during which SO3 concentrations would be sufficient for ash conditioning. An additional benefit of this technique is speculated to result from increased flue gas humidity.  相似文献   

7.
Simplified algorithms are presented for estimating the cost of controlling sulfur dioxide (SO2) emissions from existing coal-fired power plants on a state-by-state basis. Results are obtained using the detailed Utility Control Strategy Model (UCSM) to calculate the Impacts of emission reductions ranging from approximately 30 percent to 90 percent of projected 1995 emissions for 18 different scenarios and 36 states. Scenarios include the use of two dry SO2 removal technologies (lime spray dryers and LIMB) as potential options for power plant retrofit, in addition to currently available emission control options including coal switching, coal cleaning and wet flue gas desulfurization (FGD). Technical assumptions relating to FGD system performance and the upgrading of existing cold-side electrostatic precipitators (ESP) for reduced sulfur levels are also analyzed, along with the effects of interest rates, coal prices, coal choice restrictions, plant lifetime, and plant operating levels. Results are summarized in the form of a 3-term polynomial equation for each state, giving total annualized SO2 control cost as a function of the total SO2 emissions reduction for each scenario. Excellent statistical fits to UCSM results are obtained for these generalized equations.  相似文献   

8.
Ontario Hydro is committed to achieving major reductions in atmospheric emissions of SO2 and NOx in accordance with regulations established by the Ontario Government. Information is provided on electricity demand in Ontario, on Ontario Hydro's generation capacity mix and on the forecast use of generation to meet demand. Emphasis is placed on the comparative economics and emissions of Ontario Hydro's nuclear and coal-fired generation and on the integration of each into a cost-effective emission control program. Emissions of SO2 and NOx will be reduced by about 25% by 1986 and by about 50% by 1990, primarily by using nuclear generation to replace coal, by purchasing hydroelectric generation from neighbouring utilities, by controlling coal sulphur levels and by selective application of emission control technology on coal-fired plants.  相似文献   

9.
Past studies indicate a nationwide potential low-sulfur coal supply deficit in 1975 arising from extremely low-sulfur State Implementation Plan requirements which cannot ail be met in time by available coal and gas cleaning technology. One means to alleviate this net deficit would be to grant variances where at least primary air quality standards would be maintained.

An extensive modeling analysis was conducted by EPA and Walden Research on a large number of power plants in 51 AQCRs located in 20 states to determine if compliance extensions at these plants could significantly reduce the projected deficit of lowsulfur coal. Using simulation modeling, air quality impact at each plant for projected 1975 operations was determined with application of SIP regulatory requirements and with a full variance from SIP requirements for coal-fired boilers. The results from this investigation indicate that the attainment of primary SO2 air quality standards for the coal-fired plants would probably not be jeopardized by the application of full variance status to 34% of the plants and limited variance status to an additional 22% of the plants. No variance is appropriate for the remaining plants. The projected annual reduction In low-sulfur coal demand (less than 1.0% sulfur) is approximately 137 million tons. The projected shift in the average coal sulfur distribution is from 1.2% under SIP status to 2.1% under the applicable variance status. The power plant variance strategy appears, then, to offer a potentially feasible approach toward alleviating the low-sulfur coal deficit problem without jeopardizing attainment of primary air quality standards. It should be emphasized that compliance extensions are not the only way, or the most desirable way, of dealing with this problem. The final selection of a strategy for a given state or AQCR and the implementation of that strategy involve many questions and policy matters beyond the scope of this study.  相似文献   

10.
Results from a detailed analysis of sulfur dioxide (SO2) reductions achievable through “deep” physical coal cleaning (PCC) at 20 coal-fired power plants in the Ohio-Indiana-Illinois region are presented here. These plants all have capacities larger than 500 MWe, are currently without any flue gas desulfurization (FGD) systems, and burn coal of greater than l%sulfur content (in 1980). Their aggregate emissions of 2.4 million tons of SO2 per year represents 55% of the SO2 inventory for these states. The principal coal supplies for each power plant were identified and characterized as to coal seam and county of origin, so that published coal-washability data could be matched to each supplier. The SO2 reductions that would result from deep cleaning each coal (Level 4) were calculated using an Argonne computer model that assumes a weight recovery of 80%. Percentage reductions in sulfur content ranged from zero to 52%, with a mean value of 29%, and costs ranged from a low of $364/ton SO2 removed to over $2000/ton SO2 removed. Because coal suppliers to these power plants employ some voluntary coal cleaning, the anticipated emissions reduction from current levels should be near 20%. Costs then were estimated for FGD systems designed to remove the same amount of SO2 as was achieved by PCC through the use of partial scrubbing with bypass of the remaining flue gas. On this basis, PCC was more cost-effective than FGD for about 50% of the plants studied and had comparable costs for another 25% of the plants. Possible governmental actions to either encourage or mandate coal cleaning were identified and evaluated  相似文献   

11.
A simple data analysis method called the Tracer-Aerosol Gradient Interpretive Technique (TAGIT) is used to attribute particulate S and SO2 at Big Bend National Park in Texas and nearby areas to local and regional sources. Particulate S at Big Bend is of concern because of its effects on atmospheric visibility. The analysis used particulate S, SO2, and perfluorocarbon tracer data from six 6-hr sampling sites in and near Big Bend National Park. The data were collected in support of the Big Bend Regional Aerosol and Visibility Observational (BRAVO) Study; the field portion was conducted from July through October 1999. Perfluorocarbon tracer was released continuously from a tower at Eagle Pass, TX, approximately 25 km northeast of two large coal-fired power plants (Carbon I and II) in Coahuila, Mexico, and approximately 270 km east-southeast of Big Bend National Park. The perfluorocarbon tracer did not properly represent the location of the emissions from the Carbon power plants for individual 6-hr sampling periods and attributed only 3% of the particulate S and 27% of the SO2 at the 6-hr sites in and near Big Bend to sources represented by the tracer. An alternative approach using SO2 to tag "local" sources such as the Carbon plants attributed 10% of the particulate S and 75% of the SO2 at the 6-hr sites to local sources. Based on these two approaches, most of the regional (65-86%) and a small fraction (19-31%) of the local SO2 was converted to particulate S. The analysis implies that substantial reductions in particulate S at Big Bend National Park cannot be achieved by only reducing emissions from the Carbon power plants; reduction of emissions from many sources over a regional area would be necessary.  相似文献   

12.
This paper analyses the effect on the environment of electricity purchase from independent power producers (IPPs) in the case of Thailand. The environmental implication is evaluated in terms of the net change in emission of air pollutants with electricity purchase from IPPs by a utility. The main finding of the study is that electricity purchase from a non-dispatchable IPP plant based on coal-fired generation would increase the net emissions compared with that without the purchase from IPPs. The study also shows that the lower plant factor of the IPP plant would also increase the emission of air pollutants. Furthermore, with non-dispatchable IPP plants, the total emission of air pollutants would increase, whereas with dispatchable IPP plants the total emission would decrease with the level of electricity purchases.  相似文献   

13.
Emissions of sulfur trioxide from coal-fired power plants   总被引:1,自引:0,他引:1  
Emissions of sulfur trioxide (SO3) are a key component of plume opacity and acid deposition. Consequently, these emissions need to be low enough to not cause opacity violations and acid deposition. Generally, a small fraction of sulfur (S) in coal is converted to SO3 in coal-fired combustion devices such as electric utility boilers. The emissions of SO3 from such a boiler depend on coal S content, combustion conditions, flue gas characteristics, and air pollution devices being used. It is well known that the catalyst used in the selective catalytic reduction (SCR) technology for nitrogen oxides control oxidizes a small fraction of sulfur dioxide in the flue gas to SO3. The extent of this oxidation depends on the catalyst formulation and SCR operating conditions. Gas-phase SO3 and sulfuric acid, on being quenched in plant equipment (e.g., air preheater and wet scrubber), result in fine acidic mist, which can cause increased plume opacity and undesirable emissions. Recently, such effects have been observed at plants firing high-S coal and equipped with SCR systems and wet scrubbers. This paper investigates the factors that affect acidic mist production in coal-fired electric utility boilers and discusses approaches for mitigating emission of this mist.  相似文献   

14.
北京市燃煤的空气质量影响及其控制研究   总被引:6,自引:0,他引:6  
建立了2005年北京市燃煤污染源排放清单,利用MM5-CMAQ模型计算了各区县各行业燃煤对北京市空气质量的影响。研究表明,2005年1月北京市燃煤源对各监测站点SO_2浓度的贡献在70%以上,对PM_(10)和NO_x浓度的贡献约为20%~40%和10%~30%;7月本地燃煤源对SO_2浓度的贡献在40%~50%左右。1月采暖锅炉对空气质量影响最大,占50%~70%;7月电厂的影响最大。依据北京市奥运空气质量保障方案以及"十一五"期间能源规划,建立了2010年燃煤污染源大气排放的规划情景,并模拟了各规划措施对大气质量的改善效果。通过实施电厂脱硫脱硝除尘、炼焦工业停产、钢铁行业和水泥行业搬迁减产、供热锅炉改造、平房用煤改造等措施,与2005年相比,SO_2平均浓度下降30%左右,NO_x和PM_(10)浓度的下降幅度15%。  相似文献   

15.
Flue gas desulfurization: the state of the art   总被引:7,自引:0,他引:7  
Coal-fired electricity-generating plants may use SO2 scrubbers to meet the requirements of Phase II of the Acid Rain SO2 Reduction Program. Additionally, the use of scrubbers can result in reduction of Hg and other emissions from combustion sources. It is timely, therefore, to examine the current status of SO2 scrubbing technologies. This paper presents a comprehensive review of the state of the art in flue gas desulfurization (FGD) technologies for coal-fired boilers. Data on worldwide FGD applications reveal that wet FGD technologies, and specifically wet limestone FGD, have been predominantly selected over other FGD technologies. However, lime spray drying (LSD) is being used at the majority of the plants employing dry FGD technologies. Additional review of the U.S. FGD technology applications that began operation in 1991 through 1995 reveals that FGD processes of choice recently in the United States have been wet limestone FGD, magnesium-enhanced lime (MEL), and LSD. Further, of the wet limestone processes, limestone forced oxidation (LSFO) has been used most often in recent applications. The SO2 removal performance of scrubbers has been reviewed. Data reflect that most wet limestone and LSD installations appear to be capable of approximately 90% SO2 removal. Advanced, state-of-the-art wet scrubbers can provide SO2 removal in excess of 95%. Costs associated with state-of-the-art applications of LSFO, MEL, and LSD technologies have been analyzed with appropriate cost models. Analyses indicate that the capital cost of an LSD system is lower than those of same capacity LSFO and MEL systems, reflective of the relatively less complex hardware used in LSD. Analyses also reflect that, based on total annualized cost and SO2 removal requirements: (1) plants up to approximately 250 MWe in size and firing low- to medium-sulfur coals (i.e., coals with a sulfur content of 2% or lower) may use LSD; and (2) plants larger than 250 MWe and firing medium- to high-sulfur coals (i.e., coals with a sulfur content of 2% or higher) may use either LSFO or MEL.  相似文献   

16.
Anthropogenic mercury emissions in China   总被引:18,自引:0,他引:18  
An inventory of mercury emissions from anthropogenic activities in China is compiled for the year 1999 from official statistical data. We estimate that China's emissions were 536 (±236) t of total mercury. This value includes open biomass burning, but does not include natural sources or re-emission of previously deposited mercury. Approximately 45% of the Hg comes from non-ferrous metals smelting, 38% from coal combustion, and 17% from miscellaneous activities, of which battery and fluorescent lamp production and cement production are the largest. Emissions are heaviest in Liaoning and Guangdong Provinces, where extensive smelting occurs, and in Guizhou Province, where there is much small-scale combustion of high-Hg coal without emission control devices. Emissions are gridded at 30×30 min spatial resolution. We estimate that 56% of the Hg in China is released as Hg0, 32% as Hg2+, and 12% as Hgp. Particulate mercury emissions are high in China due to heavy burning of coal in residential and small industrial settings without PM controls. Emissions of Hg2+ from coal-fired power plants are high due to the absence of flue-gas desulfurization units, which tend to dissolve the soluble divalent mercury. Metals smelting operations favor the production of elemental mercury. Much of the Hg is released from small-scale activities in rather remote areas, and therefore the activity levels are quite uncertain. Also, emissions test data for Chinese sources are lacking, causing uncertainties in Hg emission factors and removal efficiencies. Overall, we calculate an uncertainty level of ±44% (95% confidence interval) in the estimate of total emissions. We recommend field testing of coal combustors and smelters in China to improve the accuracy of these estimates.  相似文献   

17.
As power production from renewable energy and natural gas grows, closures of some coal-fired power plants in Texas become increasingly likely. In this study, the potential effects of such closures on air quality and human health were analyzed by linking a regional photochemical model with a health impacts assessment tool. The impacts varied significantly across 13 of the state’s largest coal-fired power plants, sometimes by more than an order of magnitude, even after normalizing by generation. While some power plants had negligible impacts on concentrations at important monitors, average impacts up to 0.5 parts per billion (ppb) and 0.2 µg/m3 and maximum impacts up to 3.3 ppb and 0.9 µg/m3 were seen for ozone and fine particulate matter (PM2.5), respectively. Individual power plants impacted average visibility by up to 0.25 deciviews in Class I Areas. Health impacts arose mostly from PM2.5 and were an order of magnitude higher for plants that lack scrubbers for SO2. Rankings of health impacts were largely consistent across the base model results and two reduced form models. Carbon dioxide emissions were relatively uniform, ranging from 1.00 to 1.26 short tons/MWh, and can be monetized based on a social cost of carbon. Despite all of these unpaid externalities, estimated direct costs of each power plant exceeded wholesale power prices in 2016.

Implications: While their CO2 emission rates are fairly similar, sharply different NOx and SO2 emission rates and spatial factors cause coal-fired power plants to vary by an order of magnitude in their impacts on ozone, particulate matter, and associated health and visibility outcomes. On a monetized basis, the air pollution health impacts often exceed the value of the electricity generated and are of similar magnitude to climate impacts. This suggests that both air pollution and climate should be considered if externalities are used to inform decision making about power-plant dispatch and retirement.  相似文献   


18.
Mercury (Hg) is a toxic element that is emitted to the atmosphere through human activities, mainly fossil fuel combustion. Hg accumulations in soil are associated with atmospheric deposition, while coal-burning power plants remain the most important source of anthropogenic mercury emissions. In this study, we analyzed the Hg concentration in the topsoil of the Kozani–Ptolemais basin where four coal-fired power plants (4,065 MW) run to provide 50 % of electricity in Greece. The study aimed to investigate the extent of soil contamination by Hg using geostatistical techniques to evaluate the presumed Hg enrichment around the four power plants. Hg variability in agricultural soils was evaluated using 276 soil samples from 92 locations covering an area of 1,000 km2. We were surprised to find a low Hg content in soil (range 1–59 μg kg?1) and 50 % of samples with a concentration lower than 6 μg kg?1. The influence of mercury emissions from the four coal-fired power plants on soil was poor or virtually nil. We associate this effect with low Hg contents in the coal (1.5–24.5 μg kg?1) used in the combustion of these power plants (one of the most Hg-poor in the world). Despite anthropic activity in the area, we conclude that Hg content in the agricultural soils of the Kozani–Ptolemais basin is present in low concentrations.  相似文献   

19.
Selective catalytic reduction (SCR) technology increasingly is being applied for controlling emissions of nitrogen oxides (NOx) from coal-fired boilers. Some recent field and pilot studies suggest that the operation of SCR could affect the chemical form of mercury (Hg) in coal combustion flue gases. The speciation of Hg is an important factor influencing the control and environmental fate of Hg emissions from coal combustion. The vanadium and titanium oxides, used commonly in the vanadia-titania SCR catalyst for catalytic NOx reduction, promote the formation of oxidized mercury (Hg2+). The work reported in this paper focuses on the impact of SCR on elemental mercury (Hg0) oxidation. Bench-scale experiments were conducted to investigate Hg0 oxidation in the presence of simulated coal combustion flue gases and under SCR reaction conditions. Flue gas mixtures with different concentrations of hydrogen chloride (HCl) and sulfur dioxide (SO2) for simulating the combustion of bituminous coals and subbituminous coals were tested in these experiments. The effects of HCl and SO2 in the flue gases on Hg0 oxidation under SCR reaction conditions were studied. It was observed that HCl is the most critical flue gas component that causes conversion of Hg0 to Hg2+ under SCR reaction conditions. The importance of HCl for Hg0 oxidation found in the present study provides the scientific basis for the apparent coal-type dependence observed for Hg0 oxidation occurring across the SCR reactors in the field.  相似文献   

20.
This paper analyzes the air quality impacts of coal-fired power plants in the northern passageway of the West-East Power Transmission Project in China. A three-layer Lagrangian model called ATMOS, was used to simulate the spatial distribution of incremental sulfur dioxide (SO2) and coarse particulate matter (PM10) concentrations under different emission control scenarios. In the year 2005, the emissions from planned power plants mainly affected the air quality of Shanxi, Shaanxi, the common boundary of Inner Mongolia and Shanxi, and the area around the boundary between Inner Mongolia and Ningxia. In these areas, the annually averaged incremental SO2 and PM10 concentrations exceed 2 and 2.5 microg/m3, respectively. The maximum increases of the annually averaged SO2 and PM10 concentrations are 8.3 and 7.2 microg/m3, respectively, which occur around Hancheng city, near the boundary of the Shaanxi and Shanxi provinces. After integrated control measures are considered, the maximum increases of annually averaged SO2 and PM10 concentrations fall to 4.9 and 4 microg/m3, respectively. In the year 2010, the areas affected by planned power plants are mainly North Shaanxi, North Ningxia, and Northwest Shanxi. The maximum increases of the annually averaged SO2 and PM10, concentrations are, respectively, 6.3 and 5.6 microg/m3, occurring in Northwest Shanxi, which decline to 4.4 and 4.1 microg/m3 after the control measures are implemented. The results showed that the proposed power plants mainly affect the air quality of the region where the power plants are built, with little impact on East China where the electricity will be used. The influences of planned power plants on air quality will be decreased greatly by implementing integrated control measures.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号