首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
Abstract

Although aldehydes contribute to ozone and particulate matter formation, there has been little research on the biofiltration of these volatile organic compounds (VOCs), especially as mixtures. Biofiltration degradation kinetics of an aldehyde mixture containing hexanal, 2-methylbutanal (2-MB), and 3-methylbutanal (3-MB) was investigated using a bench-scale, synthetic, media-based biofilter. The adsorption capacity of the synthetic media for a model VOC, 3-methylbutanal, was 10 times that of compost. Periodic residence time distribution analysis (over the course of 1 yr) via a tracer study (84–99% recovery), indicated plug flow without channeling in the synthetic media and lack of compaction in the reactor. Simple first-order and zero-order kinetic models both equally fit the experimental data, yet analysis of the measured rate constants versus fractional conversion suggested an overall first-order model was more appropriate. Kinetic analysis indicated that hexanal had a significantly higher reaction rate (k = 0.09 ± 0.005 1/sec; 23 ± 1.3 ppmv) compared with the branched aldehydes (k = 0.04 ± 0.0036 1/sec; 31 ± 1.6 ppmv for 2-MB and 0.03 ± 0.0051 1/sec; 22 ± 1.3 ppmv for 3-MB). After 3 months of operation, all three compounds reached 100% removal (50 sec residence time, 18–46 ppmv inlet). Media samples withdrawn from the biofilter and observed under scanning electron microscopy analysis indicated microbial growth, suggesting removal of the aldehydes could be attributed to biodegradation.  相似文献   

2.
Increasing public concerns over odors and air regulations in nonattainment zones necessitate the remediation of a wide range of volatile organic compounds (VOCs) generated in the poultry-rendering industry. Currently, wet scrubbers using oxidizing chemicals such as chlorine dioxide (ClO2) are utilized to treat VOCs. However, little information is available on the kinetics of ClO2 reaction with rendering air pollutants, limiting wet scrubber design and optimization. Kinetic analysis indicated that ClO2 does not react with hexanal and 2-methylbutanal regardless of pH and temperature and implied that aldehyde removal occurs primarily via mass transfer. Contrary to the aldehydes, ethanethiol or ethyl mercaptan (a model compound for methanethiol or methyl mercaptan) and dimethyl disulfide (DMDS) rapidly reacted with ClO2. The overall reaction was found to be second and third order for ethanethiol and DMDS, respectively. Moreover, an increase in pH from 3.6 to 5.1 exponentially increased the reaction rate of ethanethiol (e.g., k2 = 25-4200 L/mol/sec from pH 3.6 to 5.1) and significantly increased the reaction rate of DMDS if increased to pH 9 (k3 = 1.4 x 10(6) L2/mol2/sec). Thus, a small increase in pH could significantly improve wet scrubber operations for removal of odor-causing compounds. However, an increase in pH did not improve aldehyde removal. The results explain why aldehyde removal efficiencies are much lower than methanethiol and DMDS in wet scrubbers using ClO2.  相似文献   

3.
Cai Z  Kim D  Sorial GA 《Chemosphere》2007,68(6):1090-1097
Two independent parallel trickling bed air biofilters (TBABs) ("A" and "B") with two different typical VOC mixtures were investigated. Toluene, styrene, methyl ethyl ketone (MEK), and methyl isobutyl ketone (MIBK) were the target VOCs in the mixtures. Biofilter "A" was fed equal molar ratio of the VOCs and biofilter "B" was fed a mixture based on EPA 2003 emission report. Backwashing and substrate starvation operation were conducted as biomass control. Biofilter "A" and "B" maintained 99% overall removal efficiency for influent concentration up to 500 and 300 ppmv under backwashing operating condition, respectively. The starvation study indicated that it can be an effective biomass control for influent concentrations up to 250 ppmv for biofilter "A" and 300 ppmv for "B". Re-acclimation of biofilter performance was delayed with increase of influent concentration for both biofilters. Starvation operation helped the biofilter to recover at low concentrations and delayed re-acclimation at high concentrations. Furthermore, re-acclamation for biofilter "B" was delayed due to its high toluene content as compared to biofilter "A". The pseudo first-order removal rate constant decreased with increase of volumetric loading rate for both biofilters. MEK and MIBK were completely removed in the upper 3/8 media depth. While biofilter depth utilization for the removal of styrene and toluene increased with increase of influent concentrations for both biofilters. However, toluene removal utilized more biofilter depth for biofilter "B" as compared to biofilter "A".  相似文献   

4.
The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture. A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20-100%).  相似文献   

5.
In this study, biofiltration using a natural wood chip medium and a commercial biofiltration medium was evaluated for the removal of moderate concentrations of hydrogen sulfide (H2S) (up to 100 parts per million by volume [ppmv]) in the presence of significant concentrations of ammonia (NH3). These levels were chosen as representative of wastewater lift station emissions in the Brownsville, TX, area. NH3-removing portions of the biofilms may compete with H2S-removing portions and inhibit H2S removal. H2S process removal efficiencies for the commercial and natural media ranged from 90 to 96% depending on inlet loading and media type and bed height. Kinetic analysis of the H2S removal process followed apparent first-order reaction behavior. The average first-order reaction rates were 0.03 sec(-1) for the commercial medium and 0.09 sec(-1) for the natural medium. Pressure drops across the columns ranged from 0.41 in. H2O/ft for the commercial medium to 1.41 in. H2O/ft for the natural medium. NH3 gas levels of up to 80 ppmv did not affect the H2S removal process efficiency, and calculated kinetic rate constants for H2S removal remained almost the same. The NH3 gas also was removed simultaneously with the H2S up to 98% removal efficiency by the commercial medium.  相似文献   

6.
Abstract

The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture.

A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20–100%).  相似文献   

7.
The long-term stability of a biofilter loaded with waste gases containing NH3 concentrations larger than 100 ppmv was studied in a laboratory-scale compost reactor. At an empty bed residence time (tau) of 21 sec, elimination capacities of more than 300 g NH3/m3/day were obtained at elimination efficiencies up to 87%. Because of absorption and nitrification, almost 80% of the NH3-N eliminated from the waste gas could be recovered in the compost as NH4(+)-N or NO2-/NO3(-)-N. The high elimination capacities could be maintained as long as the NH4+/ NOX- concentration in the carrier material was less than 4 g NH4+/NOx(-)-N/kg wet compost. Above this critical value, osmotic effects inhibited the nitrifying activity, and the elimination capacity for NH3 decreased. To restore the biofilter performance, a carbon source (methanol) was added to reduce NH4+/NOx- accumulated in the compost. Results indicate that methylotrophic microorganisms did convert NH4+/NOx- into biomass, as long as the NO3- content in the compost was larger than 0.1 g NO3(-)-N/kg compost. Removal efficiencies of CH3OH of more than 90% were obtained at volumetric loads up to 11,000 g CH3OH/ m3/day. It is shown that addition of CH3OH is a suitable technique for regenerating the compost material from osmotic inhibition as a result of high NH3 loading. The biofilter was operated for 4 months with alternating load ing of NH3 and CH3OH.  相似文献   

8.
The purpose of this research was to neutralize livestock-generated ammonia by using biofilters packed with inexpensive inorganic and organic packing material combined with multicultural microbial load at typical ambient temperatures. Peat and inorganic supporting materials were used as biofiltration matrix packed in a perfusion column through which gas was transfused. Results show the ammonia removal significantly fell in between 99 and 100% when ammonia concentration of 200 ppmv was used at different gas flow rates ranged from 0.030 to 0.060 m3 h(-1) at a fluctuating room temperature of 27.5 +/- 4.5 C (Mean +/- SD). Under these conditions, the emission concentration of ammonia that is liberated after biofiltration is less than 1 ppmv (0.707 mg m(-3)) over the period of our study, suggesting the usage of low-cost biofiltration systems for long-term function is effective at wider ranges of temperature fluctuations. The maximum (100%) ammonia removal efficiency was obtained in this biofilter was having an elimination capacity of 2.217 g m(-3) h(-1). This biofilter had high nitrification efficiencies and hence controlled ammonia levels with the reduced backpressure. The response of this biofilter to shut down and start up operation showed that the biofilm has a superior stability.  相似文献   

9.
This study was conducted to evaluate the effects of gas inlet concentration and velocity on the biofiltration of gasoline vapor. Gasoline vapor was treated using a compost biofilter operated in an upflow mode for about 3 months. The inlet concentration of gasoline total petroleum hydrocarbon (TPH) ranged from about 300 to 7000 mgm(-3) and gas was injected at velocities of 6 and 15 mh(-1) (empty bed residence time (EBRT)=10 and 4 min, respectively). The maximum elimination capacities of TPH at 6 and 15 mh(-1) found in this research were over 24 and 19 gm(-3) of filling material h(-1), respectively. TPH removal data was fit using a first-order kinetic relationship. In the low concentration range of 300-3000 mg m(-3), the first-order kinetic constants varied between about 0.10 and 0.29 min(-1) regardless of gas velocities. At TPH concentrations greater than 3000 mgm(-3), the first-order kinetic constants were about 0.09 and 0.07 min(-1) at gas velocities of 6 mh(-1) and 15 mh(-1), respectively. To evaluate microbial dynamics, dehydrogenase activity, CO2 generation and microbial species diversity were analyzed. Dehydrogenase activity could be used as an indicator of microbial activity. TPH removal corresponded well with CO2 evolution. The average CO2 recovery efficiency for the entire biofilter ranged between 60% and 70%. When the gas velocity was 6 mh(-1), most of the microbial activity and TPH removal occurred in the first quarter of the biofilter. However, when the gas velocity was 15 mh(-1), the entire column contributed to removal. Spatial and temporal variations in the biofilter microbial population were also observed. Nearly 60% of the colonies isolated from the compost media prior to biofiltration were Bacillus. After 90 days of biofiltration, the predominant species in the lower portion (0-50 cm) of the filter were Rhodococcus, while Pseudomonas and Acinetobacter dominated the upper portion (75-100 cm).  相似文献   

10.
Formaldehyde, acetaldehyde, acetone, propanal, butanal, 2-butenal, 3-methylbutanal, hexanal, benzaldehyde, 2-methylbenzaldehyde, and 2,5-dimethylbenzaldehyde were measured during six spring days at downtown Santiago de Chile. Measurements were performed 24h/day and averaged over three hour periods. The averages of the maxima (ppbv) were, formaldehyde: 3.9+/-1.4; butanal: 3.3+/-3.4; acetaldehyde: 3.0+/-0.9; acetone: 2.4+/-1.0; 2-butenal: 0.56+/-0.52; propanal: 0.46+/-0.21; benzaldehyde: 0.34+/-0.3; 3-butanal: 0.11+/-0.05; hexanal: 0.11+/-0.08; 2-methylbenzaldehyde: 0.08+/-0.05; 2,5-dimethylbenzaldehyde: 0.05+/-0.03. Aliphatic aldehydes (C1-C3) are strongly correlated among them and weakly with primary (toluene) and secondary (ozone plus nitrogen dioxide or PAN) pollutants. In particular, the correlation between acetaldehyde and propanal values remains even if diurnal and nocturnal data are considered separately, indicating similar sources. All these aldehydes present maxima values in the morning (9-12h) and minima at night (0-3h). The best correlation is observed when butanal and 2-butenal data are considered (r=0.99, butanal/2-butenal=6.2). These compounds present maxima values during the 3-6h period, with minima values in the 0-3h period. These data imply a strong pre-dawn emission. Other aldehydes show different daily profiles, suggesting unrelated origins. Formaldehyde is the aldehyde whose concentration values best correlate with the levels of oxidants. The contribution of primary emissions and photochemical processes to formaldehyde concentrations were estimated by using a multiple regression. This treatment indicates that (32+/-16)% of measured values arise from direct emissions, while (79+/-23)% is attributable to secondary formation.  相似文献   

11.
Lee TH  Kim J  Kim MJ  Ryu HW  Cho KS 《Chemosphere》2006,63(2):315-322
With ketone pollution forming an ever-growing problem, it is important to identify a ketone-degrading microorganism and establish its effect. Here, a methyl ethyl ketone (MEK)-degrading bacterium, Pseudomonas sp. KT-3, was isolated and its MEK degradation characteristics were examined in liquid cultures and a polyurethane-packed biofilter. In liquid cultures, strain KT-3 could degrade other ketone solvents, including diethyl ketone (DK), methyl propyl ketone (MPK), methyl isopropyl ketone (MIPK), methyl isobutyl ketone (MIBK), methyl butyl ketone (MBK) and methyl isoamyl ketone (MIAK). The maximum specific growth rate (mumax) of the isolate was 0.136 h(-1) in MEK medium supplemented with MEK as a sole carbon source, and kinetically, the maximum removal rate (Vm) and saturation constant (Km) for MEK were 12.28 mM g(-1)DCW h(-1) (DCW: dry cell weight) and 1.64 mM, respectively. MEK biodegradation by KT-3 was suppressed by the addition of MIBK or acetone, but not by toluene. In the tested biofilter, KT-3 exhibited a>90% removal efficiency for MEK inlet concentrations of around 500 ppmv at a space velocity (SV) of 150 h(-1). The elimination capacity of MEK was more influenced by SV than by the inlet concentration. Kinetic analysis showed that the maximum MEK removal rate (Vm) was 690 g m(-3) h(-1) and the saturation constant (Km) was 490 ppmv. Collectively, these results indicate the polyurethane sequencing batch biofilter with Pseudomonas sp. KT-3 will provide an excellent performance in the removal of gaseous MEK.  相似文献   

12.
Research was performed to demonstrate the removal of carbon tetrachloride (CT) using compost biofilters operated under methanogenic conditions. Biofilters were operated at an empty-bed residence time of 2.8 minutes using nitrogen as the atmosphere. Hydrogen and carbon dioxide were supplied as an electron donor and carbon source, respectively, during acclimation of the bed medium microbes. Once methanogenesis was demonstrated, CT flow to the biofilter was established. Biofilters were operated over a CT concentration range from 20 to 700 ppbv for 6 months. Bed medium microbes were able to remove up to 75% of the inlet CT. At excessively high CT concentrations (> 500 ppmv), methane production and hydrogen utilization by the bed medium microbes appeared to be inhibited. CT removal by the biofilter decreased when the hydrogen supply was removed from the biofilter inlet, indicating that hydrogen acted as the electron donor for reductive dechlorination. The removal efficiency and relatively low empty bed residence times demonstrated by these laboratory-scale biofilters indicate that anaerobic biofiltration of CT may be a feasible full-scale process.  相似文献   

13.
Abstract

A laboratory-scale compost-based biofilter was operated over a six-month period to study the requirements for removal of n-hexane from air. Hexane is a relatively short chain aliphatic hydrocarbon with a high Henry's coefficient and a low water solubility. Acclimation of the biofilter was slow, but removal efficiencies around 80% were achieved after one month of operation. However, performance decreased during the next two months of operation to 50% removal efficiency. Nutrient limitation was proposed as a reason for the decrease in reactor performance. After the addition of a concentrated nitrogen solution, reactor performance increased almost immediately to >99%. Removal efficiency remained above 99% for the following two months of operation at inlet concentrations of 0.7 g/m3 (200 ppmv), at superficial bed velocities approaching 50 m/h, and empty bed residence times of about one minute. Thus, nutrient availability may well limit biofilter performance even in compost- based units. It was shown that nutrients can be added effectively in a soluble form if compost quality is poor and a method is proposed for the evaluation of compost quality.  相似文献   

14.
ABSTRACT

Research was performed to demonstrate the removal of carbon tetrachloride (CT) using compost biofilters operated under methanogenic conditions. Biofilters were operated at an empty-bed residence time of 2.8 minutes using nitrogen as the atmosphere. Hydrogen and carbon dioxide were supplied as an electron donor and carbon source, respectively, during acclimation of the bed medium microbes. Once methanogenesis was demonstrated, CT flow to the biofilter was established. Biofilters were operated over a CT concentration range from 20 to 700 ppbv for 6 months. Bed medium microbes were able to remove up to 75% of the inlet CT. At excessively high CT concentrations (>500 ppmv), methane production and hydrogen utilization by the bed medium microbes appeared to be inhibited. CT removal by the biofilter decreased when the hydrogen supply was removed from the biofilter inlet, indicating that hydrogen acted as the electron donor for reductive dechlorination. The removal efficiency and relatively low empty bed residence times demonstrated by these laboratory-scale biofilters indicate that anaerobic biofiltration of CT may be a feasible full-scale process.  相似文献   

15.
Abstract

Increasing public concerns over odors and air regulations in nonattainment zones necessitate the remediation of a wide range of volatile organic compounds (VOCs) generated in the poultry-rendering industry. Currently, wet scrubbers using oxidizing chemicals such as chlorine dioxide (ClO2) are utilized to treat VOCs. However, little information is available on the kinetics of ClO2 reaction with rendering air pollutants, limiting wet scrubber design and optimization. Kinetic analysis indicated that ClO2 does not react with hexanal and 2-methylbutanal regardless of pH and temperature and implied that alde-hyde removal occurs primarily via mass transfer. Contrary to the aldehydes, ethanethiol or ethyl mercaptan (a model compound for methanethiol or methyl mercaptan) and dimethyl disulfide (DMDS) rapidly reacted with ClO2. The overall reaction was found to be second and third order for ethanethiol and DMDS, respectively. Moreover, an increase in pH from 3.6 to 5.1 exponentially increased the reaction rate of ethanethiol (e.g., k 2 = 25– 4200 L/mol/sec from pH 3.6 to 5.1) and significantly increased the reaction rate of DMDS if increased to pH 9 (k 3 = 1.4 × 106 L2/mol2/sec). Thus, a small increase in pH could significantly improve wet scrubber operations for removal of odor-causing compounds. However, an increase in pH did not improve aldehyde removal. The results explain why aldehyde removal efficiencies are much lower than methanethiol and DMDS in wet scrub-bers using ClO2.  相似文献   

16.
The influence of nutrient conditions on the degradation of toluene vapor in a rotatory-switching biofilter (RSB) was investigated. The biofilter consists of four segments connected in series, each with a packing layer made of polyvinyl formal. The influent airstreams including toluene vapors were passed through segments 1-3 as up-flow with a toluene concentration of 0.9-1.2 g m(-3) and with an empty-bed retention time of 26-52 sec. Nutrient solutions were fed to all packed segments once a day by means of immersion. The nutrient solution was used repeatedly and replenished by the addition of (NH4)2SO4. The result at 155 days showed nitrogen depletion was particularly obvious and the lack of nitrogen affected toluene removal. By adding 161 g of nitrogen solution per volumetric cubic meter of reactor, toluene removal efficiency was immediately increased to greater than 99%. With long-term biofilter operation, 21%-32% of ammonium was utilized for nitrification because of the growth of nitrifying bacteria such as Nitrosomonas sp. Based on the carbon-nitrogen balance, the daily nitrogen demand for toluene removal was estimated 2.1 g day(-1) at a toluene load of 70 g m(-3) hr(-1).  相似文献   

17.
A high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon(-1). Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (approximately 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.  相似文献   

18.
One of the main challenges that face successful biofiltration is the erratic loading pattern and long starvation periods. However, such patterns are common in practical applications. In order to provide long-term stable operation of a biofilter under these conditions, a cyclic adsorption/desorption beds system with flow switching was installed prior to a biofilter. Different square waves of a mixture containing n-hexane and benzene at a 2:1 ratio were applied to the cyclic adsorption/desorption beds and then fed to a biofilter. The performance of this integrated system was compared to a biofilter unit receiving the same feed of both VOCs. The cyclic adsorption/desorption beds unit successfully achieved its goal of stabilizing erratic loading even with very sharp peaks at the influent concentration equalizing influent concentrations ranging from 10-470 ppmv for n-hexane to 30-1410 ppmv for benzene. The study included different peak concentrations with durations ranging from 6 to 20 min. The cyclic beds buffered the fluctuating influent load and the followed biofilter had all the time a continuous stable flow. Another advantage achieved by the cyclic adsorption/desorption beds was the uninterrupted feed to the biofilter even during the starvation where there was no influent in the feed. The results of the integrated system with regard to removal efficiency and kinetics are comparable to published results with continuous feed studies at the same loading rates. The removal efficiency for benzene had a minimum of 85% while for n-hexane ranged from 50% to 77% according to the loading rate. The control unit showed very erratic performance highlighting the benefit of the utilization of the cyclic adsorption/desorption beds. The biofilter was more adaptable to concentration changes in benzene than n-hexane.  相似文献   

19.
The characteristics of ammonia removal by two types of biofilter (a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow) were investigated. A mixture of organic materials such as compost, bark, and peat was used as the biofilter media based on the small-scale column test for media selection. Complete removal capacity, defined as the maximum inlet load of ammonia that was completely removed, was obtained. The modified biofilter showed complete removal up to 1.0 g N/kg dry material/day. However, the removal capacity of the standard biofilter started to deviate from complete removal around 0.4 g N/kg dry material/day, indicating that the modified biofilter system has higher removal efficiency than the standard upflow one. In kinetic analysis of the biological removal of ammonia in each biofilter system, the maximum removal rate, Vm, was 0.93 g N/kg dry material/day and the saturation constant, Ks, was 32.55 ppm in the standard biofilter. On the other hand, the values of Vm and Ks were 1.66 g N/kg dry material/day and 74.25 ppm, respectively, in the modified biofilter system.  相似文献   

20.
Development and performance of an alternative biofilter system   总被引:3,自引:0,他引:3  
Step tracer tests were carried out on lab-scale biofilters to determine the residence time distributions (RTDs) of gases passing through two types of biofilters: a standard biofilter with vertical gas flow and a modified biofilter with horizontal gas flow. Results were used to define the flow patterns in the reactors. "Non-ideal flow" indicates that the flow reactors did not behave like either type of ideal reactor: the perfectly stirred reactor [often called a "continuously stirred tank reactor" (CSTR)] or the plug-flow reactor. The horizontal biofilter with back-mixing was able to accommodate a shorter residence time without the usual requirement of greater biofilter surface area for increased biofiltration efficiency. Experimental results indicated that the first bed of the modified biofilter behaved like two CSTRs in series, while the second bed may be represented by two or three CSTRs in series. Because of the flow baffles used in the horizontal biofilter system, its performance was more similar to completely mixed systems, and hence, it could not be modeled as a plug-flow reactor. For the standard biofilter, the number of CSTRs was found to be between 2 and 9 depending on the airflow rate. In terms of NH3 removal efficiency and elimination capacity, the standard biofilter was not as good as the modified system; moreover, the second bed of the modified biofilter exhibited greater removal efficiency than the first bed. The elimination rate increased as biofilter load increased. An opposite trend was exhibited with respect to removal efficiency.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号