首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 625 毫秒
1.
This study considers the characteristics of ground-level ozone (O3) in five Korean cities over a time period of 6-8 years. The focus of this study is daily maximum 1-hr and 8-hr concentrations. For all the study cities in the period examined, the mean and most of the percentiles (5, 10, 25, 50, 75, 90, and 95) for the daily maximum 1-hr and 8-hr concentrations showed increasing trends, although not all trends were statistically significant. The daily maximum 1-hr and 8-hr concentrations slowly increased during late winter, and peaks were attained during the summer season (from May to September). All the selected cities exhibited a high degree of correlation between their daily maximum 8-hr and 1-hr concentrations. The daily maximum 8-hr concentrations, which were climatologically equivalent to the Korean 1 hr/100 parts per billion (ppb) standard, were higher than the current 8 hr/60 ppb by a difference of 8-16 ppb. Compared with other cities in Korea, Seoul recorded a substantially higher frequency of days and hours with concentrations above 1 hr/100 ppb, and a higher frequency of days with concentrations above 8 hr/60 ppb and 8 hr/80 ppb. Seoul also recorded a substantially higher frequency of hours with concentrations above 1 hr/100 ppb than days with concentrations above 1 hr/100 ppb, implying that on some days severe exceedances persisted for more than one hour per day. During multiple-day episodes a North Pacific High dominated Korea, which is quite typical in Korea during the summer season.  相似文献   

2.
Ozone measurements are reported for five rural sites in the Tennessee Valley region of the southeastern U.S. for periods ranging from 18 to 83 months during the years 1977 through 1984. Rural ozone (O3) levels were found to equal or exceed urban values for the same region. The daily maximum 1-h average concentration was found to peak during the summer months, while the 24-h average concentrations were greatest in the spring. The annual cycle of daily maximum concentrations is related to the seasonal photochemical cycle. The annual cycle in 24-h average concentrations is best explained by the combined effects of the annual cycles in solar intensity and noctural O3 depletion. There was no indication that stratospheric intrusions exhibited a significant influence on the annual O3 cycles. Evidence was found for elevated O3 levels during touchdown of plumes from large power plants. No long-term trend in rural O3 concentrations, either daily maxima or means, was discernible.  相似文献   

3.
This study considers the characteristics of carbon monoxide (CO), nitrogen dioxide (NO(2)), ozone (O(3)) and sulfur dioxide (SO(2)) in two major South Korean cities, including the capital city of Seoul, over a time period of 7-8 years. Changes in the annual mean and percentiles of the daily 1-h maximum and other hour-based concentrations varied according to the compound and city type. Seasonal variations varied according to the compound, yet not with the city type. Both Seoul and Taegu exhibited lower O(3) concentrations in July compared to other summer months. There was a high degree of correlation between the daily 1- and 8-h maximum or daily mean concentrations of all compounds in both cities, with an R(2) of 0.66-0.90 at p<0.0001. It was indicated that for CO and O(3), the 8-h standard was more stringent than the 1-h standard, while for NO(2) and SO(2), the 1-h standard was more stringent than the 24-h standard. The correlation coefficients between the daily 1-h maximum and daily mean concentrations decreased as the maximum concentration values of NO(2), O(3 ), and SO(2) increased in the two cities. For all the target compounds, Seoul recorded a substantially higher frequency of days with concentrations above the relevant 1-, 8-, and 24-h standards compared to Taegu.  相似文献   

4.
ABSTRACT

This study considers the characteristics of ground-level ozone (O3) in five Korean cities over a time period of 6-8 years. The focus of this study is daily maximum 1-hr and 8-hr concentrations. For all the study cities in the period examined, the mean and most of the percentiles (5, 10, 25, 50, 75, 90, and 95) for the daily maximum 1-hr and 8hr concentrations showed increasing trends, although not all trends were statistically significant. The daily maximum 1-hr and 8-hr concentrations slowly increased during late winter, and peaks were attained during the summer season (from May to September). All the selected cities exhibited a high degree of correlation between their daily maximum 8-hr and 1-hr concentrations. The daily maximum 8-hr concentrations, which were climatologi-cally equivalent to the Korean 1 hr/100 parts per billion (ppb) standard, were higher than the current 8 hr/60 ppb by a difference of 8-16 ppb. Compared with other cities in Korea, Seoul recorded a substantially higher frequency of days and hours with concentrations above 1 hr/100 ppb, and a higher frequency of days with concentrations above 8 hr/60 ppb and 8 hr/80 ppb. Seoul also recorded a substantially higher frequency of hours with concentrations above 1 hr/100 ppb than days with concentrations above 1 hr/100 ppb, implying that on some days severe exceedances persisted for more than one hour per day. During multiple-day episodes a North Pacific High dominated Korea, which is quite typical in Korea during the summer season.  相似文献   

5.
Ozone concentrations were measured at two (urban and a rural) sites near the city of Málaga (Spain). The aim of this study was to determine the daily, monthly and seasonal variation patterns of ozone concentrations at both sites and to study the possible regional influences. The daily variations mostly have the usual features with the afternoon maximum and the night minimum being more pronounced in the urban area. The average monthly concentrations throughout the year start to increase in March reaching their maximum values in July for the urban site. However, in the rural area, the monthly variations are smaller reaching their maximum value in June. The hourly evolution of the ozone concentrations in both sampling sites is well defined in spring and summer and not so well defined in autumn and winter. Taking into account the four seasons, the rural concentrations are higher than the urban ones. Summer is the season when there are similar concentrations at both sampling sites. Average hourly summer afternoon ozone for the hours 12:00-20:00 LST exceeded the 110 microg m(-3) European Union guidelines for human health for 8 h ozone exposure at the urban and rural sites.  相似文献   

6.
In this study, long-term aerosol particle total number concentration measurements in five metropolitan areas across Europe are presented. The measurements have been carried out in Augsburg, Barcelona, Helsinki, Rome, and Stockholm using the same instrument, a condensation particle counter (TSI model 3022). The results show that in all of the studied cities, the winter concentrations are higher than the summer concentrations. In Helsinki and in Stockholm, winter concentrations are higher by a factor of two and in Augsburg almost by a factor of three compared with summer months. The winter maximum of the monthly average concentrations in these cities is between 10,000 cm(-3) and 20,000 cm(-3), whereas the summer min is approximately 5000-6000 cm(-3). In Rome and in Barcelona, the winters are more polluted compared with summers by as much as a factor of 4-10. The winter maximum in both Rome and Barcelona is close to 100,000 cm(-3), whereas the summer minimum is > 10,000 cm(-3). During the weekdays the maximum of the hourly average concentrations in all of the cities is detected during the morning hours between 7 and 10 a.m. The evening maxima were present in Barcelona, Rome, and Augsburg, but these were not as pronounced as the morning ones. The daily maxima in Helsinki and Stockholm are close or even lower than the daily minima in the more polluted cities. The concentrations between these two groups of cities are different with a factor of about five during the whole day. The study pointed out the influence of the selection of the measurement site and the configuration of the sampling line on the observed concentrations.  相似文献   

7.
Three years of hourly averaged PM10 (particulate matter less than 10 microns in diameter) tapered element oscillating microbalance (TEOM) data from 10 sites in the large coastal valley incorporating Greater Vancouver were used to investigate the spatiotemporal dimensions and air pollution meteorology of particulate pollution. During the period studied, the provincial "acceptable" objective daily concentration of 50 micrograms m-3 was exceeded at 7 of the 10 sites. The highest annual, seasonal, and maximum hourly concentrations were recorded at Abbotsford in the central valley. Mean seasonal PM10 concentrations were highest in the wintertime in the western Lower Fraser Valley (LFV) and in the summertime at the central and eastern valley locations. Within the network, interstation correlations of daily average concentrations exceed 0.8 at interstation distances less than 20 km and decrease thereafter. For daily maximum concentrations (hourly), interstation correlations decrease sharply with distance. Meteorological conditions responsible for elevated particulate concentrations in the LFV are associated with (1) short periods (1- to 3-hr duration) of reduced dispersion during summer nights at sites close to primary sources, (2) summer anticyclonic conditions when photochemical pollutant concentrations build up across the entire valley, and (3) occasional wintertime "gap wind" events in the eastern valley.  相似文献   

8.
Numerous papers analyze ground-level ozone (O3) trends since the 1980s, but few have linked O3 trends with observed changes in nitrogen oxide (NOx) and volatile organic compound (VOC) emissions and ambient concentrations. This analysis of emissions and ambient measurements examines this linkage across the United States on multiple spatial scales from continental to urban. O3 concentrations follow the general decreases in both NOx and VOC emissions and ambient concentrations of precursors (nitrogen dioxide, NO2; nonmethane organic compounds, NMOCs). Annual fourth-highest daily peak 8-hr average ozone and annual average or 98th percentile daily maximum hourly NO2 concentrations show a statistically significant (p < 0.05) linear fit whose slope is less than 1:1 and intercept is in the 30 to >50 ppbv range. This empirical relationship is consistent with current understanding of O3 photochemistry. The linear O3–NO2 relationships found from our multispatial scale analysis can be used to extrapolate the rate of change of O3 with projected NOx emission reductions, which suggests that future declines in annual fourth-highest daily average 8-hr maximum O3 concentrations are unlikely to reach 65 ppbv or lower everywhere in the next decade. Measurements do not indicate increased annual reduction rates in (high) O3 concentrations beyond the multidecadal precursor proportionality, since aggressive measures for NOx and VOC reduction are in place and have not produced an accelerated O3 reduction rate beyond that prior to the mid-2000s. Empirically estimated changes in O3 with emissions suggest that O3 is less sensitive to precursor reductions than is found by the CAMx (v. 6.1) photochemical model. Options for increasing the rate of O3 change are limited by photochemical factors, including the increase in NOx sensitivity with time (NMOC/NOx ratio increase), increase in O3 production efficiency at lower NOx concentrations (higher O3/NOy ratio), and the presence of natural NOx and NMOC precursors and background O3.

Implications:?This analysis demonstrates empirical relations between O3 and precursors based on long term trends in U.S. locations. The results indicate that ground-level O3 concentrations have responded predictably to reductions in VOC and NOx since the 1980s. The analysis reveals linear relations between the highest O3 and NO2 concentrations. Extrapolation of the historic trends to the future with expected continued precursor reductions suggest that achieving the 2014 proposed reduction in the U.S. National Ambient Air Quality Standard to a level between 65 and 70 ppbv is unlikely within the next decade. Comparison of measurements with national results from a regulatory photochemical model, CAMx, v. 6.1, suggests that model predictions are more sensitive to emissions changes than the observations would support.  相似文献   

9.
Abstract

In this study, long-term aerosol particle total number concentration measurements in five metropolitan areas across Europe are presented. The measurements have been carried out in Augsburg, Barcelona, Helsinki, Rome, and Stockholm using the same instrument, a condensation particle counter (TSI model 3022). The results show that in all of the studied cities, the winter concentrations are higher than the summer concentrations. In Helsinki and in Stockholm, winter concentrations are higher by a factor of two and in Augsburg almost by a factor of three compared with summer months. The winter maximum of the monthly average concentrations in these cities is between 10,000 cm-3 and 20,000 cm-3, whereas the summer min is ?;5000–6000 cm-3. In Rome and in Barcelona, the winters are more polluted compared with summers by as much as a factor of 4–10. The winter maximum in both Rome and Barcelona is close to 100,000 cm-3, whereas the summer minimum is >10,000 cm-3. During the weekdays the maximum of the hourly average concentrations in all of the cities is detected during the morning hours between 7 and 10 a.m. The evening maxima were present in Barcelona, Rome, and Augsburg, but these were not as pronounced as the morning ones. The daily maxima in Helsinki and Stockholm are close or even lower than the daily minima in the more polluted cities. The concentrations between these two groups of cities are different with a factor of about five during the whole day. The study pointed out the influence of the selection of the measurement site and the configuration of the sampling line on the observed concentrations.  相似文献   

10.
太湖流域小型水源性湖泊氮、磷时空分布及营养状态评价   总被引:3,自引:0,他引:3  
2009年11月至2010年10月,对太湖流域小型水源性湖泊20个采样点水体的TN、TP、NO3--N、NH4+-N、NO2--N以及PO43-等水质因子进行测定分析,讨论了氮、磷时空分布特征,并评价其富营养化程度。结果表明,TN、TP年均值分别为1.50、0.05mg/L;TN、TP的季节性变化规律具有一定差异,TN浓度为冬、春季高于夏、秋季,而TP浓度为2009年11月至2010年3月高于其他月份。由于受入湖河流的影响,TN、TP的空间分布格局较为相似,均表现为西南部高于东北部、入湖口分别高于湖中心和出湖口。NO3--N年均值为0.68mg/L,浓度变化趋势呈双峰型(2010年3、9月为峰值),基本同TN的变化趋势一致,空间分布表现为入湖口分别低于湖中心和出湖口(除冬季外),显示水体硝化过程对硝酸盐的贡献。NH4+-N年均值为0.23mg/L,从2010年4月开始浓度逐渐升高,到2010年7月达到全年最高值,其浓度空间分布特征表现为入、出湖口均高于湖中心(除秋季外)。NO2--N和PO43-的年均值都较低,均为0.01mg/L(以P计),时空差异不明显。根据CARLSON提出的营养状态指数法计算分析可知,该湖泊冬、春季处于中营养状态,夏、秋季营养状态略高,且磷是全年初级生产力的限制因子。  相似文献   

11.
ABSTRACT

Three years of hourly averaged PM10 (particulate matter less than 10 Lrm in diameter) tapered element oscillating microbalance (TEOM) data from 10 sites in the large coastal valley incorporating Greater Vancouver were used to investigate the spatiotemporal dimensions and air pollution meteorology of particulate pollution. During the period studied, the provincial “acceptable” objective daily concentration of 50 μg m-3 was exceeded at 7 of the 10 sites. The highest annual, seasonal, and maximum hourly concentrations were recorded at Abbotsford in the central valley. Mean seasonal PM10 concentrations were highest in the wintertime in the western Lower Fraser Valley (LFV) and in the summertime at the central and eastern valley locations. Within the network, interstation correlations of daily average concentrations exceed 0.8 at interstation distances less than 20 km and decrease thereafter. For daily maximum concentrations (hourly), interstation correlations decrease sharply with distance. Meteorological conditions responsible for elevated par-ticulate concentrations in the LFV are associated with (1) short periods (1- to 3-hr duration) of reduced dispersion during summer nights at sites close to primary sources, (2) summer anticyclonic conditions when photochemical pollutant concentrations build up across the entire valley, and (3) occasional wintertime “gap wind” events in the eastern valley.  相似文献   

12.
Natural radionuclides have been proposed as a means of assessing the transport of ozone (O3) and aerosols in the troposphere. Beryllium-7 (7Be) is produced in the upper troposphere and lower stratosphere by the interaction of cosmogenic particles with atmospheric nitrogen and oxygen. 7Be has a 53.29-day half-life (478 keV gamma) and is known to attach to fine particles in the atmosphere once it is formed. It has been suggested that O3 from aloft can be transported into rural and urban regions during stratospheric-tropospheric folding events leading to increased background levels of O3 at the surface. 7Be can be used as a tracer of upper atmospheric air parcels and the O3 associated with them. Aerosol samples with a 2.5-microm cutoff were collected during 12-hr cycles (day/night) for a 30-day period at Deer Park, TX, near Houston, in August-September of 2000, and at Waddell, AZ, near Phoenix, in June-July of 2001. A comparison of 7Be levels with 12-hr O3 averages and maxima shows little correlation. Comparison of nighttime and daytime O3 levels indicate that during the day, when mixing is anticipated to be higher, the correlation of 7Be with O3 in Houston is approximately twice that observed at night. This is consistent with mixing and with the anticipated loss of O3 by reaction with nitric oxide (NO) and dry deposition. At best, 30% of the O3 variance can be explained by the correlation with 7Be for Houston, less than that for Phoenix where no significant correlation was seen. This result is consistent with the intercept values obtained for 7Be correlations with either O3 24-hr averages or O3 12-hr maxima and is also in the range of the low O3 levels (25 ppb) observed at Deer Park during a tropical storm event where the O3 is attributable primarily to background air masses. That is, maximum background O3 level contributions from stratospheric sources aloft are estimated to be in the range of 15-30 ppb in the Houston, TX, and Phoenix, AZ, area, and levels above these are because of local tropospheric photochemical production.  相似文献   

13.
Ozone concentrations in Alberta cities typically exhibit a maximum in May (up to 35 ppb) and a minimum in November (as low as 4 ppb). This behaviour is similar to that of rural Alberta O3 concentrations. Annual O3 concentrations at six urban monitoring stations vary from 11 ppb to 22 ppb and are about one-half the values at rural stations. In winter, urban O3 concentrations are always smaller than rural concentrations and the cities act as sinks for O3. Although urban stations do not exceed Canada's maximum acceptable levels of daily (25 ppb) and annual (15 ppb) O3 concentrations as often as rural stations, the frequency is still quite large. Canada's hourly maximum desirable level (50 ppb) is exceeded 11 times more often at the remote (rural) station than at the downtown (urban) stations.  相似文献   

14.
Ambient concentrations of ozone (O3), nitrogen oxides (NOx), total reactive nitrogen (NOy), nitric acid (HNO3), and hydrogen peroxide (H2O2) were measured during September 2003 at an urban site of Cincinnati, OH. The aim of this study was two-fold: to investigate whether O3 formation in this population exposure-type site is NOx, sensitive or volatile organic compound (VOC) sensitive and to test the practicality of using two combined observational-based methods to identify the sensitivity of O3 formation in midlevel polluted locations. The evaluation of the indicator species: NOy, O3/NOy, O3/HNO3, H2O2/ HNO3, and O3/(estimated NOx reaction products), as well as the combined hypothesis testing analysis of the weekend/weekday (WE/WD) differences of 1-hr and 8-hr average maximum O3 and of the 6:00 a.m.-9:00 a.m. average nitric oxide and NOx concentrations, show evidence that Cincinnati is likely VOC sensitive. Average WE 1-hr and 8-hr maximum O3, as well as duration of WE O3 accumulation, were not lower than the corresponding WD levels in spite of the observed significant reduction in NO, emissions on WE, a typical situation in VOC-sensitive locations. The possibility that the seasonal transition from summer to autumn could have influenced the results was also investigated through an exploratory analysis of the afternoon O3 maximum/NOx measured and of the WE/WD differences of peak O3 and morning average NO and NO, concentrations observed at this site from June through September 2003. The results suggest that a VOC-sensitive chemistry regime dominated along the summer season. The findings of this study suggest that additional reductions in regional NO, emissions in Cincinnati, a potential nonattainment area under the 8-hr O3 standard, may cause an increase in local O3. Future strategies to reduce O3 in Southwest Ohio should be further evaluated carefully. The combination of observational-based methods might provide a consistent complementary approach in the identification of the NO,-VOC sensitive characteristics of mid-to-moderate polluted urban areas.  相似文献   

15.
Time-resolved data is needed for public notification of unhealthful air quality and to develop an understanding of atmospheric chemistry, including insights important to control strategies. In this research, continuous fine particulate matter (PM2.5) mass concentrations were measured with tapered element oscillating microbalances (TEOMs) across New Jersey from July 1997 to June 1998. Data features indicating the influence of local sources and long-distance transport are examined, as well as differences between 1-hr maxima and 24-hr average concentrations that might be relevant to acute health effects. Continuous mass concentrations were not significantly different from filter-collected gravimetric mass concentrations with 95% confidence intervals during any season. Annual mean PM2.5 concentrations from July 1997 to June 1998 were 17.3, 16.4, 14.1, and 15.3 micrograms/m3 at Newark, Elizabeth, New Brunswick, and Camden, NJ, respectively. Monthly averaged 24- and 1-hr daily maximum PM2.5 concentrations suggest the existence of a high PM2.5 (May-October) and a low PM2.5 (November-April) season. PM2.5 magnitudes and temporal trends were very similar across the state during high PM2.5 events. In fact, the between-site coefficients of determination (R2) for daily PM2.5 measurements were 84-98% for June and July. Additionally, during the most pronounced PM2.5 episode, PM2.5 concentrations closely tracked the daily maximum 1-hr O3 concentrations. These observations suggest the importance of transport and atmospheric chemistry (i.e., secondary formation) to PM2.5 episodes in New Jersey. The influence of local sources was observed in diurnal concentration profiles and annual average between-site differences. Urban wintertime data illustrate that high 1-hr maximum PM2.5 concentrations can occur on low 24-hr PM2.5 days.  相似文献   

16.
In Houston, some of the highest measured 8-hr ozone (O3) peaks are characterized by sudden increases in observed concentrations of at least 40 ppb in 1 hr or 60 ppb in 2 hr. Measurements show that these large hourly changes appear at only a few monitors and span a narrow geographic area, suggesting a spatially heterogeneous field of O3 concentrations. This study assessed whether a regulatory air quality model (AQM) can simulate this observed behavior. The AQM did not reproduce the magnitude or location of some of the highest observed hourly O3 changes, and it also failed to capture the limited spatial extent. On days with measured large hourly changes in O3 concentrations, the AQM predicted high O3 over large regions of Houston, resulting in overpredictions at several monitors. This analysis shows that the model can make high O3, but on these days the predicted spatial field suggests that the model had a different cause. Some observed large hourly changes in O3 concentrations have been linked to random releases of industrial volatile organic compounds (VOCs). In the AQM emission inventory, there are several emission events when an industrial point source increases VOC emissions in excess of 10,000 mol/hr. One instance increased predicted downwind O3 concentrations up to 25 ppb. These results show that the modeling system is responsive to a large VOC release, but the timing and location of the release, and meteorological conditions, are critical requirements. Attainment of the O3 standard requires the use of observational data and AQM predictions. If the large observed hourly changes are indicative of a separate cause of high O3, then the model may not include that cause, which might result in regulators enacting control strategies that could be ineffective.  相似文献   

17.

Introduction

The Turia river basin, located in the east of the Iberian Peninsula, drains into the Mediterranean Sea near the city of Valencia (population, 814,208). The predominance of sea-breeze fluxes favours the inland transport of pollutants from the city up the basin where ozone concentrations exceeding the threshold for protection of human health are systematically recorded during the summer months.

Methods

This work analyses the variability in ozone levels by examining their spatial and temporal distribution in a Mediterranean river basin downwind from a city within the period 2005?C2008. Orographic determinants and atmospheric fluxes induce strong variations in ozone measurements, even on relatively close locations.

Conclusions

Results show a different behaviour of the monthly means and the daily cycles depending on the season of the year and the measuring environment, with summer/winter ratios ranging from 2.4 in cities to 1.6 inland, and mean values always higher in the interior of the basin. Daily cycles show significant summer/winter differences related to the predominant situations of anticyclonic stability in winter, which limit ventilation, and the predominant breeze circulations in summer. Results also show a ??weekend effect?? at urban and medium-distance stations. At the most inland station, the weekend/weekday behaviour differs according to the season of the year; weekend ozone levels are higher in spring, autumn and winter, and lower in summer, coinciding with the predominance of local wind cycles that favour air mass penetration inland from the coast.  相似文献   

18.
The weekly cycles of atmospheric ozone (O3) are of interest because they provide information about the response of O3 to changes in anthropogenic emissions from weekdays to weekends. The weekly behavior of O3 in Chicago, IL; Philadelphia, PA; and Atlanta, GA, is contrasted. In Chicago and Philadelphia, maximum 1-hr average O3 increases on weekends. In Atlanta, O3 builds up from Mondays to Fridays and declines during weekends. In all three areas, volatile organic compound (VOC)/nitrogen oxides (NOx) ratios are higher during weekends, resulting from greater than proportionate decreases in NOx relative to VOC emissions. The VOC/NOx ratios correlate with maximum 1-hr O3 concentrations in Chicago, a response consistent with a VOC-sensitive airshed. A weak correlation between O3 concentrations and VOC/NOx ratios in Philadelphia suggests the impact of transported O3, which is formed in upwind VOC-sensitive locations that may be hundreds of kilometers away. Ozone concentrations in Atlanta do not correlate with VOC/NOx ratios but with concentrations of NOx and total reactive nitrogen (NOy) carried over from the previous day. When data from 1986-1990 and 1995-1999 are compared, only small differences in the weekly behavior of O3 are observed in Chicago and Philadelphia. The day-of-week differences in O3 are amplified in the more recent period in Atlanta, a possible result of urban growth.  相似文献   

19.
Weekly and seasonal variations of surface ozone and their precursors – nitrogen oxides, carbon monoxide-associated with meteorological parameters (wind direction, temperature, solar radiation) – are reported. Measurements were performed continuously during 2006 at two sampling stations located in the metropolitan area of Porto Alegre, Brazil. Results have shown that O3 concentrations remained almost constant between weekdays. Levels of NOx precursors decreased especially on Sundays, due to lighter traffic. The seasonal variation has shown a maximum O3 concentration during summer and spring while NOx and NO2 have maxima at the colder months. The daily cycle of highest ozone concentrations reveals a lower nightly level and an inverse relation between O3 and NOx, evidencing the photochemical formation of O3. There are seasonal variation and source heterogeneity.  相似文献   

20.
Measurements of C2–C5 hydrocarbons on an hourly basis at the TNO site in Delft from 1982 to 1984 and at Moerdijk over the period 1981–1991 are presented. In combination with meteorological data (wind direction and wind speed) the Delft and Moerdijk series are evaluated to identify source categories, annual variations, background concentrations and trends. The C2–C5 hydrocarbon concentrations at Delft and Moerdijk are determined mainly by emission characteristics and meteorological dispersion; the dominant sources are relatively nearby and atmospheric degradation is not of much importance. Under conditions of high wind speed the concentrations measured at Moerdijk in the marine sector are close to the Atlantic background concentrations in winter and somewhat above this in summer. The continental background concentrations are higher than the marine background concentrations by a factor of almost two. The annual variation of acetylene is more pronounced than that of the other hydrocarbons, most likely due to a different seasonal variation in acetylene emissions. The annual variation of propene is smoother, indicating stronger sources in summer than in winter. This feature of propene is observed in continental as well as in marine sectors. The observations show that at Moerdijk C2–C4 concentrations measured in Rijnmond sector have decreased considerably since the early 1980s, corresponding with changes in emissions in that area. Averaged over all wind directions the trend of all species is downward, but for acetylene the trend is significant at a 95% confidence interval. The acetylene concentrations show an annual downward trend of 3% during the 1980s, supporting other estimates of decreasing hydrocarbon emissions from traffic over this period at the same rate.  相似文献   