首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 812 毫秒
1.
采用UASB-膜生物反应器对抗生素废水进行处理研究。结果表明,UASB具有很强的抗冲击能力,当UASB和膜生物反应器的容积负荷分别为10.9kgCOD/m3·d和4.62kgCOD/m3·d时,系统COD去除率仍有96.47%。污泥浓度对膜生物反应器的COD去除率有较大影响,当MLSS保持在3000~4000mg/L时,膜生物反应器COD去除率为85%左右,高于MLSS保持在7500~7800mg/L时为68%左右。在不排泥运行时膜生物反应器中MLVSS和MLSS比值比排泥运行时低。  相似文献   

2.
用生活污水在常温下培养厌氧颗粒污泥的研究   总被引:1,自引:0,他引:1       下载免费PDF全文
用COD为300mg/L左右的生活污水在常温下(>17·C)启动5L升流式厌氧污泥床(UASB)反应器.接种消化污泥5.6keSS/m3,初始有机容积负荷为0.6kgCOD/(m3·d),水力停留时间为8h.稳定后逐步增加有机容积负荷.一个月后即有颗粒污泥出现,50d后反应器达到稳定的处理效果.运行145d后,污泥中大于0.5mm的颗粒污泥占总重量的73.5%,最大粒径可达3mm,比重为1.07SVI在20左右,污泥中产甲烷菌主要是索氏甲烷丝菌.用颗粒化后的反应器处理生活污水时,水力停留时间可短至6~4h,当水温不低于17℃时,出水COD均低于100mg/L,可达到排放要求。   相似文献   

3.
针对榨菜废水高盐度、高有机物浓度的特点,使用UASB厌氧反应器对该废水进行处理,考察了进水盐度和pH值、接种污泥、处理负荷和反应器内温度、碱度、氧化还原电位等因素对COD去除率的影响,通过对进水中上述因素的控制,发现UASB反应器的COD去除率可以达到45%.在有机负荷不超过15.0 kgCOD/(m3 ·d)的情况下逐渐提高负荷培养颗粒化污泥、盐度不超过46.0 g/L条件下逐渐提高进水盐度以驯化和培养耐盐、嗜盐微生物,是UASB反应器高效运行的关键.运行后期,耐盐微生物出现在颗粒污泥中.  相似文献   

4.
厌氧处理乙酸丁酯废水的实验研究   总被引:1,自引:0,他引:1  
乙酸丁酯废水是一种重要的化工原料,每生产一顿乙酸丁酯可产生140kg废水,本实验利用3L上流式厌氧污泥床UASB反应器在中温条件下处理高浓度乙酸丁酯废水。当UASB反应器稳定运行时,进水CODcr=10000mg/L时,容积负荷可达到13kgCOD/(m^3d),水力停留时间24h,COD去除率可以达到80%以上,出水COD小于2000mg/L。通过本试验取得的良好试验效果,为处理乙酸丁酯废水找出了可行的途径。  相似文献   

5.
潘碌亭  王键  罗华飞 《环境科学》2009,30(11):3324-3328
采用上流式厌氧污泥床(UASB)反应器,以高浓度羧甲基纤维素(CMC)废水为处理对象,研究了中温条件下UASB反应器的启动、颗粒污泥特性和废水处理效果.结果表明,采用接种颗粒污泥与消化污泥的混合泥进行培养,并逐步提高进水CMC废水浓度,运行80 d后,可实现UASB反应器的启动;当进水COD值达到4 000 mg/L,容积负荷6.86 kg/(m3.d),COD去除率在80%以上;反应器内污泥实现颗粒化,且颗粒污泥的比产甲烷活性良好.  相似文献   

6.
在常温下研究利用EGSB反应器处理环氧树脂生产废水的启动运行。结果表明:水力负荷和污泥负荷是影响EGSB反应器处理效果的重要参数,水力负荷在0.8~3 m/h,进水COD浓度在2500~7500 mg/L的范围内,COD的去除率在80%以上;运行时反应器内的污泥负荷稳定在0.4 kgCOD/(kgSS·d)左右,通过提高水力负荷,有利于污泥的生长;污泥经过启动驯化后能够适应EGSB反应器的运行条件。  相似文献   

7.
UASB改进工艺处理橡胶助剂废水的中试研究   总被引:3,自引:0,他引:3  
利用改进的UASB厌氧生物反应器对橡胶助剂废水的中试研究表明 ,该工艺能够有效地处理这种难降解废水。在试验过程中 ,进水浓度COD为 50 0 0~ 1 2 0 0 0mg/L ,pH >8.0 ,通过对污泥的驯化培养 ,COD去除率达 80 %左右 ,运行的容积负荷可达 6.0kgCOD/ (m3·d) ,pH稳定在 7.3左右 ,能够达到预定要求并为后续的好氧处理提供保证  相似文献   

8.
文章用厌氧颗粒污泥接种启动UASB反应器,通过调节碱度和出水回流来实现浓缩果汁废水在低碱度下的稳定运行。研究结果表明:经35天UASB反应器可完全启动,负荷为9.5gCOD(/L·d),COD去除率在80%以上;回流比为0.3,进水碱度和pH值分别为1500mg/L和6.75、1000mg/L和6.52时,反应器能够稳定运行;采用出水回流的方法可以使酸性的浓缩果汁废水厌氧处理大幅度降低用碱量甚至完全不加碱的条件下实现稳定运行,本试验在回流比为8~10时,反应器也有很好的处理效果。通过对其控制条件实验室研究,显著的降低了浓缩果汁废水的处理成本,在工程上具有广泛的应用性。  相似文献   

9.
为探索周期性厌氧折流板反应器(PABR)处理生活污水的实际运行效果,研究了PABR反应器的启动,考察了反应器在启动过程中的处理效果及厌氧污泥特征。结果表明,在低温(3~18℃)条件下,进水COD浓度180~350 mg/L时,通过逐步缩短水力停留时间(HRT)(20 h-12 h-12 h)来提高有机负荷,最后固定HRT为12 h,完成PABR的启动。启动完成后,COD平均去除率为75%,出水COD浓度在60~90 mg/L,容积负荷为0.7 kg COD/(m3·d),出水pH在7.3左右,挥发性脂肪酸(VFA)的浓度为160 mg/L左右,碱度在280 mg/L左右,反应器每日处理量约为2.1 m3。PABR反应器前端的1#、2#隔室对COD的去除分别占总去除率的53%和40%;1#、2#隔室污泥的污泥浓度、可沉降性、污泥活性等均优于后端3#、4#隔室。PABR反应器处理生活污水在低温下可以成功启动并稳定运行。  相似文献   

10.
本文报导采用生物厌氧消化和好氧净化处理相结合的生物系统工程处理屠宰废水的试验,在常温(25±1℃)条件下,厌氧进水COD2200-2500mg/L,厌氧一级处理采用UASB生物反应器,HRT8h,有机负荷平均6.95kgCOD/m~3·d,其COD去除率70~80%,产气率为1.2~1.3L/L·d,CH_4含量平均60%以上;经厌氧——好氧联合试验处理,其COD总去除率可达90%以上,出水COD≤200mg/L。  相似文献   

11.
本文采用厌氧反应器UASB+膜生物反应器MBR+纳滤工艺处理垃圾填埋场废水,设计处理能力为100m3/d,在进水CODs:和BODs分别为10 000 mg/L和5 000 mg/L时,经处理后,出水CODc:和BODs分别为60mg/L和20mg/L,其去除率分别为99.4%和99.6%,且出水稳定,达到了<北京市水...  相似文献   

12.
高氮渗滤液缺氧/厌氧UASB-SBR工艺低温深度脱氮   总被引:7,自引:1,他引:6       下载免费PDF全文
在低温条件下,采用缺氧/厌氧UASB-SBR组合工艺处理实际垃圾填埋场渗滤液.结果表明,该工艺可实现有机物和氮的同步、深度去除.在进水COD平均为11950.2mg/L,NH4+-N为982.7mg/L的条件下,出水分别为390.1mg/L和2.9mg/L,去除率分别为96.7%和99.7%.同时,缺氧UASB1反应器的最大COD负荷达到13kg/(m3×d),最大COD去除速率为12.39 kg/(m3×d),具有高效缺氧反硝化和高效厌氧降解有机物反应的双重功效, 在SBR反应器的缺氧段和缺氧UASB,反应器内获得了99%以上的反硝化率.对于冬季水温分别为14.9,14.1,13.5,11.05℃的低温条件下,SBR反应器实现了完全硝化和反硝化,出水TN分别为4.1,5.7,14.1,16.5mg/L,达到了深度脱氮的目的.此外,在上述温度范围内,温度对反硝化速率(rN)的影响大于对硝化速率 (rDN)的影响, rN/rDN比值相对恒定.  相似文献   

13.
垃圾渗沥液中氨氮的电化学氧化   总被引:21,自引:0,他引:21       下载免费PDF全文
针对目前国内外垃圾渗沥液处理中存在的问题,采用电化学氧化与上流式厌氧污泥床(UASB)相结合,研究建立了对香港垃圾渗沥液的二步法处理工艺.本文着重探讨了电化学间接氧化去除渗沥液中氨氮的反应机制及主要影响因素,并通过实验找出了最佳的操作条件:入水初始 pH值为9.0;流速为0.01-0.10cm/s;CI加入量2000mg/L;电流密度 32.3mA/cm2.在此条件下,经过 6h电解后,UASB反应器出水中NH-N和COD的去除率分别达到100%和87%.对该电化学氧化过程的运行成本进行了评估.  相似文献   

14.
Nitrogen removal via nitrite from municipal landfill leachate   总被引:2,自引:0,他引:2  
A system consisting of a two-stage up-flow anaerobic sludge blanket (UASB), an anoxic/aerobic (A/O) reactor and a sequencing batch reactor (SBR), was used to treat landfill leachate. During operation, denitrification and methanogenesis took place simultaneously in the first stage UASB, and the e uent chemical oxygen demand (COD) was further removed in the second stage UASB. Then the denitrification of nitrite and nitrate in the returned sludge by using the residual COD was accomplished in the A/O reactor, and ammonia was removed via nitrite in it. Last but not least, the residual ammonia was removed in SBR as well as nitrite and nitrate which were produced by nitrification. The results over 120 d (60 d for phase I and 60 d for phase II) were as follows: when the total nitrogen (TN) concentration of influent leachate was about 2500 mg/L and the ammonia nitrogen concentration was about 2000 mg/L, the shortcut nitrification with 85%–90% nitrite accumulation was achieved stably in the A/O reactor. The TN and ammonia nitrogen removal e ciencies of the system were 98% and 97%, respectively. The residual ammonia, nitrite and nitrate produced during nitrification in the A/O reactor could be washed out almost completely in SBR. The TN and ammonia nitrogen concentrations of final e uent were about 39 mg/L and 12 mg/L, respectively.  相似文献   

15.
以序批式反应器培养的好氧颗粒污泥作为接种污泥,驯化处理上流式厌氧颗粒污泥床反应器的出水,整个运行过程主要分为颗粒污泥驯化阶段和稳定运行阶段。在稳定运行阶段,有机COD负荷可达到5.2 g/L.d,COD去除率高于95%,好氧颗粒污泥直径集中于3.5~6mm,SVI 50~58mL/g,沉降速率在72~90m/h,好氧颗粒污泥具有良好的沉降性能和较高的COD去除率。同时应用扫描电镜技术对接种颗粒污泥和驯化后的好氧颗粒污泥的微生物结构进行了初步观察和分析。  相似文献   

16.
The soluble microbial products (SMP) in the biological treatment effluent are generally of great amount and are poorly biodegradable. Focusing on the biodegradation of anaerobic SMP, the biological activated carbon (BAC) was introduced into the anaerobic system. The experiments were conducted in two identical lab-scale up-flow anaerobic sludge blanket (UASB) reactors. The high strength organics were degraded in the first UASB reactor (UASB1) and the second UASB (UASB2, i.e., BAC) functioned as a polishing step to remove SMP produced in UASB1. The results showed that 90% of the SMP could be removed before granular activated carbon was saturated. After the saturation, the SMP removal decreased to 60% on the average. Analysis of granular activated carbon adsorption revealed that the main role of SMP removal in BAC reactor was biodegradation. A strain of SMP-degrading bacteria, which was found highly similar to Klebsiella sp., was isolated, enriched and inoculated back to the BAC reactor. When the influent chemical oxygen demand (COD) was 10,000 mg/L and the organic loading rate achieved 10 kg COD/(m 3 ·day), the effluent from the BAC reactor could meet the discharge standard without further treatment. Anaerobic BAC reactor inoculated with the isolated Klebsiella was proved to be an effective, cheap and easy technical treatment approach for the removal of SMP in the treatment of easily-degradable wastewater with COD lower than 10,000 mg/L.  相似文献   

17.
采用连续运行1119d的上流式厌氧污泥床(UASB)反应器,研究了最佳有机负荷条件下氨氮和硫酸盐对模拟废水中谷氨酸降解性能的抑制作用.结果表明,有机负荷为8.0g COD/(L·d)时,COD去除率达到最高值为(97.94±0.28)%.逐步提高进水氨氮浓度,起初对谷氨酸降解性能的影响不大;但升到2000mg/L时COD去除率和甲烷产率明显降低,继续升至4000mg/L时即达到半抑制状态.逐步提高进水硫酸盐浓度至4000mg/L,甲烷产率和溶液中游离硫化氢(FS)浓度分别呈现一直下降和升高趋势,但COD去除率均能维持在90%以上.进水中的氨氮和硫酸盐分别因离解平衡和生物还原作用形成游离氨(FAN)和FS,进而抑制了产甲烷菌的活性;前者因FAN扩散到细胞内部破坏质子平衡从而过多消耗ATP,后者还因硫酸盐还原菌的增殖存在底物竞争抑制作用.  相似文献   

18.
电化学氧化与厌氧技术联用处理垃圾渗沥水   总被引:13,自引:0,他引:13  
采用电化学氧化与上流式厌氧污泥床(UASB)结合技术,提出了处理香港垃圾渗沥水的二步法工艺.对含COD和NH3-N分别为4750mg/L和1310mg/L的垃圾渗沥水,首先进行UASB预处理(消化温度37℃,COD负荷0.78g/(L·d),HRT为6.1d),获得了66%的COD去除率;UASB的出水被引入电化学氧化反应器进行深度处理.在外加Cl 2000mg/L,电流密度为32.3mA/cm2的条件下,经6h的电解间接氧化,COD和NH3-N的去除率分别达到87%和100%,出水的COD为209mg/L,并且不含NH3-N,此过程的COD电能消耗<55kW·h/kg.本文讨论了电化学氧化过程中电极反应原理,各实验参数对COD和NH3-N去除率的影响,以及电能消耗与运行成本评估等.  相似文献   

19.
采用连续运行1119d的上流式厌氧污泥床(UASB)反应器,研究了最佳有机负荷条件下氨氮和硫酸盐对模拟废水中谷氨酸降解性能的抑制作用.结果表明,有机负荷为8.0g COD/(L·d)时,COD去除率达到最高值为(97.94±0.28)%.逐步提高进水氨氮浓度,起初对谷氨酸降解性能的影响不大;但升到2000mg/L时COD去除率和甲烷产率明显降低,继续升至4000mg/L时即达到半抑制状态.逐步提高进水硫酸盐浓度至4000mg/L,甲烷产率和溶液中游离硫化氢(FS)浓度分别呈现一直下降和升高趋势,但COD去除率均能维持在90%以上.进水中的氨氮和硫酸盐分别因离解平衡和生物还原作用形成游离氨(FAN)和FS,进而抑制了产甲烷菌的活性;前者因FAN扩散到细胞内部破坏质子平衡从而过多消耗ATP,后者还因硫酸盐还原菌的增殖存在底物竞争抑制作用.  相似文献   

20.
采用微电解+厌氧折流板反应器(ABR)+上流式厌氧污泥床(UASB)+膜生物反应器(MBR)组合工艺对纤维乙醇黑液进行处理。结果表明:当黑液中COD质量浓度在12000mg/L左右,该组合工艺中厌氧停留时间(HRT)为48h时,厌氧COD去除率达到72%,MBR中的HRT为20h时,COD的去除率在80.8%~87.5%之间,出水COD质量浓度稳定在301~537mg/L.且MBR抗冲击负荷能力较强。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号