首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background, aim, and scope  The novel system of ultraviolet light-emitting diodes (UV LEDs) was studied in water disinfection. Conventional UV lamps, like mercury vapor lamp, consume much energy and are considered to be problem waste after use. UV LEDs are energy efficient and free of toxicants. This study showed the suitability of LEDs in disinfection and provided information of the effect of two emitted wavelengths and different test mediums to Escherichia coli destruction. Materials and methods  Common laboratory strain of E. coli (K12) was used and the effects of two emitted wavelengths (269 and 276 nm) were investigated with two photolytic batch reactors both including ten LEDs. The effects of test medium were examined with ultrapure water, nutrient and water, and nutrient and water with humic acids. Results  Efficiency of reactors was almost the same even though the one emitting higher wavelength had doubled optical power compared to the other. Therefore, the effect of wavelength was evident and the radiation emitted at 269 nm was more powerful. Also, the impact of background was studied and noticed to have only slight deteriorating effect. In the 5-min experiment, the bacterial reduction of three to four log colony-forming units (CFU) per cubic centimeter was achieved, in all cases. Discussion  When turbidity of the test medium was greater, part of the UV radiation was spent on the absorption and reactions with extra substances on liquid. Humic acids can also coat the bacteria reducing the sensitivity of the cells to UV light. The lower wavelength was distinctly more efficient when the optical power is considered, even though the difference of wavelengths was small. The reason presumably is the greater absorption of DNA causing more efficient bacterial breakage. Conclusions  UV LEDs were efficient in E. coli destruction, even if LEDs were considered to have rather low optical power. The effect of wavelengths was noticeable but the test medium did not have much impact. Recommendations and perspectives  This study found UV LEDs to be an optimal method for bacterial disinfection. The emitted wavelength was found to be an essential factor when using LEDs; thus, care should be taken in selecting the proper LED for maximum disinfection.  相似文献   

2.
Antibiotic-resistant bacteria are an emerging threat to public health during drinking water consumption and reclaimed water reuse. Several studies have shown that the proportions of antibiotic-resistant bacteria in waters may increase when exposed to low doses of UV light or chlorine. In this study, inactivation of tetracycline-resistant Escherichia coli and antibiotic-sensitive E. coli by UV disinfection and chlorination was compared to determine the tolerance of tetracycline-resistant E. coli to UV light and chlorine, and tetracycline resistance of a tetracycline-resistant E. coli population was studied under different doses of the disinfectants. Our results showed that relative to antibiotic-sensitive E. coli, tetracycline-resistant E. coli had the same tolerance to UV light and a potentially higher tolerance to chlorination. The mortality frequency distributions of tetracycline-resistant E. coli exposed to tetracycline were shifted by both chlorination and UV disinfection. When compared to the hemi-inhibitory concentrations (IC50) of tetracycline-resistant E. coli with no exposure to UV or chlorination, the IC50 of tetracycline-resistant E. coli treated with tetracycline was 40% lower when inactivation by UV light or chlorination reached 3-log but was 1.18 times greater when inactivation by chlorination reached 4.3-log. Chlorination applied to drinking water or reclaimed water treatment may increase the risk of selection for highly tetracycline-resistant E. coli.  相似文献   

3.
水质对紫外消毒在两种典型再生水中应用的影响   总被引:1,自引:0,他引:1  
以大肠杆菌为对象,研究了再生水水质变化对紫外消毒效果和光复活的影响。结果表明,紫外对大肠杆菌有很强的灭活作用,在紫外剂量为4mJ/cm^2时,大肠杆菌的灭活率达到了4.41个对数级。腐殖酸、铁和2种再生水水体中其他溶解性物质会影响光吸收和紫外透射率,但对紫外消毒动力学无影响。在颗粒物浓度为0~200mg/L的范围内,外源高岭土和活性污泥等颗粒物的投加对紫外消毒效果影响较小,而再生水水样W1中原有的2.61/1:g/L的颗粒物则会极大地影响消毒效果,使UV对细菌的灭活出现明显的拖尾现象。腐殖酸会增强紫外损伤大肠杆菌的光复活能力,但2种再生水中细菌的光复活能力相对磷酸盐缓冲溶液(PBS)中减弱,减弱程度在不同水样中有所不同。  相似文献   

4.
Drinking water in the vast Arctic Canadian territory of Nunavut is sourced from surface water lakes or rivers and transferred to man-made or natural reservoirs. The raw water is at a minimum treated by chlorination and distributed to customers either by trucks delivering to a water storage tank inside buildings or through a piped distribution system. The objective of this study was to characterize the chemical and microbial drinking water quality from source to tap in three hamlets (Coral Harbour, Pond Inlet and Pangnirtung—each has a population of <2000) on trucked service, and in Iqaluit (population ~6700), which uses a combination of trucked and piped water conveyance. Generally, the source and drinking water was of satisfactory microbial quality, containing Escherichia coli levels of <1 MPN/100 mL with a few exceptions, and selected pathogenic bacteria and parasites were below detection limits using quantitative polymerase chain reaction (qPCR) methods. Tap water in households receiving trucked water contained less than the recommended 0.2 mg/L of free chlorine, while piped drinking water in Iqaluit complied with Health Canada guidelines for residual chlorine (i.e. >0.2 mg/L free chlorine). Some buildings in the four communities contained manganese (Mn), copper (Cu), iron (Fe) and/or lead (Pb) concentrations above Health Canada guideline values for the aesthetic (Mn, Cu and Fe) and health (Pb) objectives. Corrosion of components of the drinking water distribution system (household storage tanks, premise plumbing) could be contributing to Pb, Cu and Fe levels, as the source water in three of the four communities had low alkalinity. The results point to the need for robust disinfection, which may include secondary disinfection or point-of-use disinfection, to prevent microbial risks in drinking water tanks in buildings and ultimately at the tap.  相似文献   

5.

Purpose

The disinfection efficiency of water and secondary treated wastewater by means of photoelectrocatalytic oxidation (PEC) using reference strains of Enterococcus faecalis and Escherichia coli as faecal indicators was evaluated. Operating parameters such as applied potential (2?C10?V), initial bacterial concentration (103?C107?CFU/mL), treatment time (up to 90?min) and aqueous matrix (pure water and treated effluent) were assessed concerning their impact on disinfection.

Methods

PEC experiments were carried out using a TiO2/Ti film anode and a zirconium cathode in the presence of simulated solar radiation. Bacterial inactivation was monitored by the culture method and real-time SYBR green PCR.

Results

A 6.2 log reduction in E. faecalis population was achieved after 15?min of PEC treatment in water at 10?V of applied potential and an initial concentration of 107?CFU/mL; pure photocatalysis (PC) led to only about 4.3 log reduction, whilst negligible inactivation was recorded when the respective electrochemical oxidation process was applied (i.e. without radiation). PEC efficiency was generally improved increasing the applied potential and decreasing initial bacterial concentration. Regarding real wastewater, E. coli was more susceptible than E. faecalis during treatment at a potential of 5?V. Wastewater disinfection was affected by its complex composition and the contained mixed bacterial populations, yielding lower inactivation rates compared to water treatment. Screening the results obtained from both applied techniques (culture method and real-time PCR), there was a discrepancy regarding the recorded time periods of total bacterial inactivation, with qPCR revealing longer periods for complete bacterial reduction.

Conclusions

PEC is superior to PC in terms of E. faecalis inactivation presumably due to a more efficient separation and utilization of the photogenerated charge carriers, and it is mainly affected by the applied potential, initial bacterial concentration and the aqueous matrix.  相似文献   

6.
Wastewater disinfection is practiced with the goal of reducing risks of human exposure to pathogenic microorganisms. In most circumstances, the efficacy of a wastewater disinfection process is regulated and monitored based on measurements of the responses of indicator bacteria. However, inactivation of indicator bacteria does not guarantee an acceptable degree of inactivation among other waterborne microorganisms (e.g., microbial pathogens). Undisinfected effluent samples from several municipal wastewater treatment facilities were collected for analysis. Facilities were selected to provide a broad spectrum of effluent quality, particularly as related to nitrogenous compounds. Samples were subjected to bench-scale chlorination and dechlorination and UV irradiation under conditions that allowed compliance with relevant discharge regulations and such that disinfectant exposures could be accurately quantified. Disinfected samples were subjected to a battery of assays to assess the immediate and long-term effects of wastewater disinfection on waterborne bacteria and viruses. In general, (viable) bacterial populations showed an immediate decline as a result of disinfectant exposure; however, incubation of disinfected samples under conditions that were designed to mimic the conditions in a receiving stream resulted in substantial recovery of the total bacterial community. The bacterial groups that are commonly used as indicators do not provide an accurate representation of the response of the bacterial community to disinfectant exposure and subsequent recovery in the environment. UV irradiation and chlorination/dechlorination both accomplished measurable inactivation of indigenous phage; however, the extent of inactivation was fairly modest under the conditions of disinfection used in this study. UV irradiation was consistently more effective as a virucide than chlorination/dechlorination under the conditions of application, based on measurements of virus (phage) diversity and concentration. Taken together, and when considered in conjunction with previously published research, the results of these experiments illustrate several important limitations of common disinfection processes as applied in the treatment of municipal wastewaters. In general, it is not clear that conventional disinfection processes, as commonly implemented, are effective for control of the risks of disease transmission, particularly those associated with viral pathogens. Microbial quality in receiving streams may not be substantially improved by the application of these disinfection processes; under some circumstances, an argument can be made that disinfection may actually yield a decrease in effluent and receiving water quality. Decisions regarding the need for effluent disinfection must account for site-specific characteristics, but it is not clear that disinfection of municipal wastewater effluents is necessary or beneficial for all facilities. When direct human contact or ingestion of municipal wastewater effluents is likely, disinfection may be necessary. Under these circumstances, UV irradiation appears to be superior to chlorination in terms of microbial quality and chemistry and toxicology. This advantage is particularly evident in effluents that contain appreciable quantities of ammonia-nitrogen or organic nitrogen.  相似文献   

7.
This paper investigates the potential of using the silver antibacterial properties combined with the metal ion exchange characteristics of silver-modified clinoptilolite to produce a treatment system capable of removing both contaminants from aqueous streams. The results have shown that silver-modified clinoptilolite is capable of completely eliminating Escherichia coli after 30-min contact time demonstrating its effectiveness as a disinfectant. Systems containing both E. coli and metals exhibited 100 % E. coli reduction after 15-min contact time and maximum metal adsorption removal efficiencies of 97, 98, and 99 % for Pb2+, Cd2+, and Zn2+ respectively after 60 min; 0.182–0.266 mg/g of metal ions were adsorbed by the zeolites in the single- and mixed-metal-containing solutions. Nonmodified clinoptilolite showed no antibacterial properties. This study demonstrated that silver-modified clinoptilolite exhibited high disinfection and heavy metal removal efficiencies and consequently could provide an effective combined treatment system for the removal of E. coli and metals from contaminated water streams.  相似文献   

8.
The UN estimated about five million deaths every year due to water-borne diseases, accounting from four billion patients. Keeping in view, the ever increasing health issues and to undermine this statistics, a reliable and sustainable water-treatment method has been developed using visible light for water treatment. titania nanoparticles (NPs) have been synthesized successfully by a more applicable method Viz: liquid impregnation (LI) method. The bacterial death rate by photocatalysis under visible light was studied by employing a typical fluorescent source and was found to follow pseudo first-order reaction kinetics. The nanoparticles were characterized using X-ray diffraction (XRD), scanning electron microscopy, and energy-dispersive X-ray spectroscopy to deduce their size range, surface morphology, and elemental compositions, respectively. Among all the prepared grades, 1 % Ag–TiO2 was found to be a very effective photocatalytic agent against Escherichia coli. The resulted photoinactivated data were also evaluated by different empirical kinetic models for bacterial inactivation. Hom, Hom-power, Rational, and Selleck models were not able to explain the disinfection kinetics but modified-Hom model fitted best with the experimentally obtained data by producing a shoulder, log-linear, and a tail region.  相似文献   

9.
Dunlop PS  Ciavola M  Rizzo L  Byrne JA 《Chemosphere》2011,85(7):1160-1166
Solar disinfection (SODIS) of Escherichia coli suspensions in low-density polyethylene bag reactors was investigated as a low-cost disinfection method suitable for application in developing countries. The efficiency of a range of SODIS reactor configurations was examined (single skin (SS), double skin, black-backed single skin, silver-backed single skin (SBSS) and composite-backed single skin) using E. coli suspended in model and real surface water. Titanium dioxide was added to the reactors to improve the efficiency of the SODIS process. The effect of turbidity was also assessed. In addition to viable counts, E. coli injury was characterised through spread-plate analysis using selective and non-selective media. The optimal reactor configuration was determined to be the SBSS bag (t50 = 9.0 min) demonstrating the importance of UVA photons, as opposed to infrared in the SODIS disinfection mechanism. Complete inactivation (6.5-log) was achieved in the presence of turbidity (50 NTU) using the SBSS bag within 180 min simulated solar exposure. The addition of titanium dioxide (0.025 g L−1) significantly enhanced E. coli inactivation in the SS reactor, with 6-log inactivation observed within 90 min simulated solar exposure. During the early stages of both SODIS and photocatalytic disinfection, injured E. coli were detected; however, irreversible injury was caused and re-growth was not observed. Experiments under solar conditions were undertaken with total inactivation (6.5-log) observed in the SS reactor within 240 min, incomplete inactivation (4-log) was observed in SODIS bottles exposed to the same solar conditions.  相似文献   

10.
Wastewater stabilization ponds (WSPs) are commonly used to treat municipal wastewater in Arctic Canada. The biological treatment in the WSPs is strongly influenced by climatic conditions. Currently, there is limited information about the removal of fecal and pathogenic bacteria during the short cool summer treatment season. With relevance to public health, the objectives of this paper were to determine if treatment in arctic WSPs resulted in the disinfection (i.e., removal of fecal indicator bacteria, Escherichia coli) and removal of selected human bacterial pathogens from the treated effluent. The treatment performance, with focus on microbial removal, was assessed for the one-cell WSP in Pond Inlet (Nunavut [NU]) and two-cell WSP in Clyde River (NU) over three consecutive (2012–2014) summer treatment seasons (late June-early September). The WSPs provided a primary disinfection treatment of the wastewater with a 2–3 Log removal of generic indicator E. coli. The bacterial pathogens Salmonella spp., pathogenic E. coli, and Listeria monocytogenes, but not Campylobacter spp. and Helicobacter pylori, were detected in the untreated and treated wastewater, indicating that human pathogens were not reliably removed. Seasonal and annual variations in temperature significantly (p < 0.05) affected the disinfection efficiency. Improved disinfection and pathogen removal was observed for the two-cell system in Clyde River as compared to the one-cell system in Pond Inlet. A quantitative microbial risk assessment should be performed to determine if the release of low levels of human pathogens into the arctic environment poses a human health risk.  相似文献   

11.
The purpose of this work was to study the efficiency of different treatments, based on the combination of O3, H2O2, and TiO2, on fresh surface water samples fortified with wild strains of Escherichia coli. Moreover, an exhaustive assessment of the influence of the different agents involved in the treatment has been carried out by kinetic modeling of E. coli inactivation results. The treatments studied were (i) ozonation (O3), (ii) the peroxone system (O3/0.04 mM H2O2), (iii) catalytic ozonation (O3/1 g/L TiO2), and (iv) a combined treatment of O3/1 g/L TiO2/0.04 mM H2O2. It was observed that the peroxone system achieved the highest levels of inactivation of E. coli, around 6.80 log after 10 min of contact time. Catalytic ozonation also obtained high levels of inactivation in a short period of time, reaching 6.22 log in 10 min. Both treatments, the peroxone system (O3/H2O2) and catalytic ozonation (O3/TiO2), produced a higher inactivation rate of E. coli than ozonation (4.97 log after 10 min). While the combination of ozone with hydrogen peroxide or titanium dioxide thus produces an increase in the inactivation yield of E. coli regarding ozonation, the O3/TiO2/H2O2 combination did not enhance the inactivation results. The fitting of experimental values to the corresponding equations through non-linear regression techniques was carried out with Microsoft® Excel GInaFiT software. The inactivation results of E. coli did not respond to linear functions, and it was necessary to use mathematical models able to describe certain deviations in the bacterial inactivation processes. In this case, the inactivation results fit with mathematical models based on the hypothesis that the bacteria population is divided into two different subgroups with different degrees of resistance to treatments, for instance biphasic and biphasic with shoulder models.
Graphical abstract ?
  相似文献   

12.
Conventional wastewater treatment is challenging in the Arctic region due to the cold climate and scattered population. Thus, no wastewater treatment plant exists in Greenland, and raw wastewater is discharged directly to nearby waterbodies without treatment. We investigated the efficiency of physicochemical wastewater treatment, in Kangerlussuaq, Greenland. Raw wastewater from Kangerlussuaq was treated by chemical coagulation and UV disinfection. By applying 7.5 mg Al/L polyaluminium chloride (PAX XL100), 73% of turbidity and 28% phosphate was removed from raw wastewater. E. coli and Enterococcus were removed by 4 and 2.5 log, respectively, when UV irradiation of 0.70 kWh/m3 was applied to coagulated wastewater. Furthermore, coagulated raw wastewater in Denmark, which has a chemical quality similar to Greenlandic wastewater, was disinfected by peracetic acid or UV irradiation. Removal of heterotrophic bacteria by applying 6 and 12 mg/L peracetic acid was 2.8 and 3.1 log, respectively. Similarly, removal of heterotrophic bacteria by applying 0.21 and 2.10 kWh/m3 for UV irradiation was 2.1 and greater than 4 log, respectively. Physicochemical treatment of raw wastewater followed by UV irradiation and/or peracetic acid disinfection showed the potential for treatment of arctic wastewater.  相似文献   

13.
Faecal indicator bacteria (FIB) are commonly used as water quality indicators; implying faecal contamination and therefore the potential presence of pathogenic enteric bacteria, viruses, and protozoa. Hence in wastewater treatment, the most commonly used treatment process measures (surrogates) are total coliforms, faecal coliforms, Escherichia coli (E. coli), and enterococci. However, greywater potentially contains skin pathogens unrelated to faecal load, and E. coli and other FIB may grow within greywater unrelated to pathogens. Overall, FIB occurs at fluctuating and relatively low concentrations compared to other endogenous greywater bacteria affecting their ability as surrogates for pathogen reduction. Therefore, unlike municipal sewage, FIB provides a very limited and unreliable log-reduction surrogate measure for on-site greywater treatment systems. Based on our recent metagenomic study of laundry greywater, skin-associated bacteria such as Staphylococcus, Corynebacterium, and Propionibacterium spp. dominate and may result in more consistent treatment surrogates than traditional FIB. Here, we investigated various Staphylococcus spp. as potential surrogates to reliably assay over 4-log10 reduction by the final-stage UV disinfection step commonly used for on-site greywater reuse, and compare them to various FIB/phage surrogates. A collimated UV beam was used to determine the efficacy of UV inactivation (255, 265 and 285 nm) against E. coli, Enterococcus faecalis, E. faecium, E. casseliflavus, Staphylococcus aureus, and S. epidermidis. Staphylococcus spp. was estimated by combining the bi-linear dose-response curves for S. aureus and S. epidermidis and was shown to be less resistant to UV irradiation than the other surrogates examined. Hence, a relative inactivation credit is suggested; whereas, the doses required to achieve a 4 and 5-log10 reduction of Staphylococcus spp. (13.0 and 20.9 mJ cm?2, respectively) were used to determine the relative inactivation of the other microorganisms investigated. The doses required to achieve a 4 and 5-log10 reduction of Staphylococcus spp. resulted in a log10 reduction of 1.4 and 4.1 for E. coli, 0.8 and 2.8 for E. faecalis, 0.8 and 3.6 for E. casseliflavus and 0.8 and 1.2 for MS2 coliphage, respectively. Given the concentration difference of Staphylococcus spp. and FIB (3 to 5-log10 higher), we propose the use of Staphylococcus spp. as a novel endogenous performance surrogate to demonstrate greywater treatment performance given its relatively high and consistent concentration and therefore ability to demonstrate over 5-log10 reductions.  相似文献   

14.
This study reports on the effect of microwave radiation for inactivation of Ascaris lumbricoides eggs in 25 g of soil compared to ultraviolet irradiation and ozone expose. Microwave radiation at 700 W with 14% water content (w/w) achieved approximately 2.5 log inactivation of eggs in soil within 60 s. On the other hand, UV irradiation at 3 mW cm−2 with and without shaking soil for 3600 s achieved approximately 0.32 and 0.01 log inactivation of eggs, respectively. In ozone treatment, 0.13 log inactivation of eggs was achieved with 5.8 ± 0.7 mg L−1 of dissolved ozone dose for 30 min in a continuous diffusion reactor. In addition, the inactivation of eggs by three disinfection techniques was conducted in water in order to compare the inactivation efficiency of eggs in soil. The inactivation efficiency of microwave radiation was found to be no significant difference between in soil and water. However, the inactivation efficiency of UV irradiation was significantly increased in water while in ozone expose there was no significant difference between in soil and water. Microwave treatment thus proved to be the most efficient method in controlling A. lumbricoides eggs in soil.  相似文献   

15.
The Ni-doped and N-doped TiO2 nanoparticles were investigated for their antibacterial activities on Staphylococcus aureus (S. aureus) and Escherichia coli (E. coli) bacteria. Their morphological features and characteristics such as particle size, surface area, and visible light absorbing capacity were compared and discussed. Scanning electron microscopy, X-ray diffraction, and UV–visible spectrophotometry were used to characterize both materials. The inactivation of E. coli (as an example of Gram-negative bacteria) and S. aureus (as an example of Gram-positive bacteria) with Ni-doped and N-doped TiO2 was investigated in the absence and presence of visible light. Antibacterial activity tests were conducted using undoped, Ni-doped, and N-doped TiO2. The N-doped TiO2 nanoparticles show higher antibacterial activity than Ni-doped TiO2. The band gap narrowing of N-doped TiO2 can induce more visible light absorption and leads to the superb antibacterial properties of this material. The complete inactivation time for E. coli at an initial cell concentration of 2.7?×?104 CFU/mL was 420 min which is longer than the 360 min required for S. aureus inactivation. The rate of inactivation of S. aureus using the doped TiO2 nanoparticles in the presence of visible light is greater than that of E. coli. The median lethal dose (LD50) values of S. aureus and E. coli by antibacterial activity under an 18-W visible light intensity were 80 and 350 mg/ml for N-doped TiO2, respectively.  相似文献   

16.
Chen Y  Lu A  Li Y  Yip HY  An T  Li G  Jin P  Wong PK 《Chemosphere》2011,84(9):1276-1281
The photocatalytic disinfection of Escherichia coli K-12 is investigated by the natural sphalerite (NS) under different spectra, wavelengths and intensities of visible light (VL) emitted by light-emitting-diode lamp (LED). The spectrum effect of VL on disinfection efficiency is studied by using white LED, fluorescent tube (FT) and xenon lamp (XE), which indicates that the “discreted peak spectrum” of FT is more effective to inactivate bacteria than “continuous spectrum” of LED and XE. Besides, the photocatalytic disinfection of bacteria is compared under different single spectrum (blue, green, yellow and red color) LEDs. The results show that the most effective wavelength ranges of VL for photocatalytic disinfection with the NS are 440-490 and 570-620 nm. Furthermore, a positive relationship is obtained between the disinfection efficiency and the VL intensity. The experiment shows that NS can completely inactivate 107 cfu mL−1E. coli K-12 within 8 h irradiation by white LED with the intensity of 200 mW cm−2 at pH 8. Moreover, the destruction process of the cell wall and the cell membrane are directly observed by TEM. Finally, no bacterial colony can be detected within a 96 h regrowth test of inactivated bacteria, which reveals that the VL-photocatalytic disinfection leads to an irreversible damage to the bacterial cells.  相似文献   

17.
The discharge of untreated or inadequately treated effluents has been identified among the activities responsible for the spread of a wide range of potentially infectious agents. The aim of this study was to determine whether inadequate treatment of wastewater and the faecal pollution load of effluents and receiving water bodies in Sedibeng District and Soshanguve peri-urban area of the Tshwane Metropolitan Municipality could be a potential threat to the health of the surrounding communities. Variations in the counts of faecal indicator bacteria and pathogenic microorganisms and compliance of the effluents and receiving water bodies with South African and World Health Organization standards were assessed between August 2011 and May 2012 using culture-based methods and molecular techniques. The overall quality of effluents did not comply with the South African special standard of no risk for unrestricted irrigation (zero?Escherichia coli/100 ml). The quality of the receiving water bodies did not comply with South African regulatory limits set for domestic purposes (zero?E.?coli/100 ml, <30 faecal enterococci/100 ml and <1 somatic coliphages/100 ml), for full contact recreation (<20 somatic coliphages/100 ml) and aquaculture (<10?E.?coli/100 ml) and WHO standards for full and intermediate contact recreational use (<1?E.?coli/100 ml and <40 faecal enterococci/100 ml, respectively). The PCR results revealed the prevalence of pathogenic microorganisms; between 0 and 60 % of samples tested positive for Salmonella Typhimurium and Shigella dysenteriae, and between 20 and 60 % of samples tested positive for Vibrio cholerae. These findings demonstrated that potential health risks might be associated with the use of the target river waters for domestic, recreational and irrigation purposes. This study calls for a prompt intervention to improve wastewater management.  相似文献   

18.
A surface- and vertical subsurface-flow-constructed wetland were designed to study the response of chlorophyll and antioxidant enzymes to elevated UV radiation in three types of wetland plants (Canna indica, Phragmites austrail, and Typha augustifolia). Results showed that (1) chlorophyll content of C. indica, P. austrail, and T. augustifolia in the constructed wetland was significantly lower where UV radiation was increased by 10 and 20 % above ambient solar level than in treatment with ambient solar UV radiation (p?C. indica, P. australis, and T. angustifolia by elevated UV radiation of 10 % was higher in vertical subsurface-flow-constructed wetland than in surface-flow-constructed wetland. The sensitivity of MDA, SOD, POD, and CAT activities of C. indica, P. austrail, and T. augustifolia to the elevated UV radiation was lower in surface-flow-constructed wetland than in the vertical subsurface-flow-constructed wetland, which was related to a reduction in UV radiation intensity through the dissolved organic carbon and suspended matter in the water. C. indica had the highest SOD and POD activities, which implied it is more sensitive to enhanced UV radiation. Therefore, different wetland plants had different antioxidant enzymes by elevated UV radiation, which were more sensitive in vertical subsurface-flow-constructed wetland than in surface-flow-constructed wetland.  相似文献   

19.
As little is known about the potential risks associated with the use of microbiologically contaminated river water for recreation, irrigation, or domestic purposes, the Msunduzi River in Pietermaritzburg (KwaZulu-Natal, South Africa) was evaluated. In addition to pH, temperature, and chemical oxygen demand, quantitative and qualitative microbiological analyses were performed monthly for 13 months. These included aerobic plate counts, counts of aerobic and anaerobic sporeformers, most probable numbers for total and faecal coliforms and Escherichia coli and the detection of Salmonella spp., Staphylococcus aureus, and intestinal enterococci. Presumptive E. coli and S. aureus from river water samples were confirmed using PCR and additionally matrix-assisted laser desorption/ionisation-time of flight mass spectrometry (MALDI-TOF MS) for E. coli. Aerobic plate counts were above the South African Department of Water Affairs recommended guideline level for domestic use of 100 cfu/ml for all 13 months assessed. Faecal coliform (up to 63,000 MPN/100 ml) and E. coli (up to 7,900 MPN/100 ml) levels regularly exceeded stipulated limits for safe irrigation, domestic and recreational use. The presence of Salmonella spp., S. aureus, and intestinal enterococci frequently coincided with faecal coliform and E. coli levels above 1,000 MPN/100 ml. This illustrates the value of using guideline values for faecal coliforms and E. coli as indicators for the presence of potential pathogens. PCR and MALDI-TOF MS confirmation of E. coli were in agreement, thereby demonstrating the potential of MALDI-TOF MS as a suitable alternative. These data demonstrate that potential health risks are associated with using Msunduzi River water for irrigation and recreational or domestic purposes.  相似文献   

20.
研究水质对254 nm紫外线透射率的影响,通过动态实验考察了照射时间、254 nm紫外线透射率以及紫外线剂量对炼化企业中水消毒效果的影响并同时考察异养菌、硫酸盐还原菌和铁细菌的光复活及暗修复现象。结果表明,有机物是影响炼化企业中水紫外线消毒的重要因素;紫外线对炼化企业中水中的异养菌具有良好的灭活作用;增加照射时间对消毒效果的提升作用受254 nm紫外线透射率的影响;紫外线透射率在较低的范围内时对消毒效果的影响相对较大,在较高的范围内时影响较小;紫外线剂量-响应曲线受254 nm紫外线透射率的影响;剂量的“成分”,即照射时间和透射率的不同组合,也会对消毒效果产生影响;在80 mJ/cm2的剂量下,20 h内异养菌出现了较强烈的光复活和暗修复现象,铁细菌仅出现了明显的光复活现象,硫酸盐还原菌没有表现出明显的复活。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号