首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
This work aimed to evaluate whether the performance of passive sampling devices in measuring time-weighted average (TWA) concentrations supports their application in regulatory monitoring of trace metals in surface waters, such as for the European Union's Water Framework Directive (WFD). The ability of the Chemcatcher and the diffusive gradient in thin film (DGT) device sampler to provide comparable TWA concentrations of Cd, Cu, Ni, Pb and Zn was tested through consecutive and overlapping deployments (7-28 days) in the River Meuse (The Netherlands). In order to evaluate the consistency of these TWA labile metal concentrations, these were assessed against total and filtered concentrations measured at relatively high frequencies by two teams using standard monitoring procedures, and metal species predicted by equilibrium speciation modeling using Visual MINTEQ. For Cd and Zn, the concentrations obtained with filtered water samples and the passive sampling devices were generally similar. The samplers consistently underestimated filtered concentrations of Cu and Ni, in agreement with their respective predicted speciation. For Pb, a small labile fraction was mainly responsible for low sampler accumulation and hence high measurement uncertainty. While only the high frequency of spot sampling procedures enabled the observation of higher Cd concentrations during the first 14 days, consecutive DGT deployments were able to detect it and provide a reasonable estimate of ambient concentrations. The range of concentrations measured by spot and passive sampling, for exposures up to 28 days, demonstrated that both modes of monitoring were equally reliable. Passive sampling provides information that cannot be obtained by a realistic spot sampling frequency and this may impact on the ability to detect trends and assess monitoring data against environmental quality standards when concentrations fluctuate.  相似文献   

2.
A cellulose acetate membrane, positioned in a passive sampler system, was coated with the perfluorinated polymer Nafion. Aqueous metal transport through the membrane and the Nafion film was investigated. The Nafion-coated membrane prevents the transport of metals bound to natural organic material to the receiving phase in the passive sampler, while copper associated with small synthetic ligands pass through the Nafion film. Increasing thickness of the Nafion film decreases the metal uptake rate to the receiving phase in the passive sampler and increases the response time. A decreased response time for the passive sampler would provide a better estimation of rapid changes in concentration, particularly for dynamic aquatic systems such as urban runoff. Limited biofouling protection with the Nafion coating was demonstrated by growth inhibition of natural periphyton communities on glass surfaces.  相似文献   

3.
一种淡水大型底栖无脊椎动物采样器研究   总被引:2,自引:2,他引:0  
研制出一种长方体的十字筐采样器,在采样器内分别填装石、砂、底泥和水草4种基质,利用大型底栖无脊椎动物对生境的选择性进行样本被动采集。基质越多,采样器采集的生物种类越多,生物量也更丰富。用新研制的十字筐采样器和传统的篮式采样器对松花江流域7个采样点进行大型底栖无脊椎动物对比采样,结果显示:十字筐采样器是一种优良的采样器,适合在松花江流域乃至全国推广应用。  相似文献   

4.
A new, passive particle deposition air sampler, called the Einstein-Lioy Deposition Sampler (ELDS), has been developed to fill a gap in passive sampling for near-field particle emissions. The sampler can be configured in several ways: with a protective hood for outdoor sampling, without a protective hood, and as a dust plate. In addition, there is an XRF-ready option that allows for direct sampling onto a filter-mounted XRF cartridge which can be used in conjunction with all configurations. A wind tunnel was designed and constructed to test the performance of different sampler configurations using a test dust with a known particle size distribution. The sampler configurations were also tested versus each other to evaluate whether or not the protective hood would affect the collected particle size distribution. A field study was conducted to test the sampler under actual environmental conditions and to evaluate its ability to collect samples for chemical analysis. Individual experiments for each configuration demonstrated precision of the sampler. The field experiment demonstrated the ability of the sampler to both collect mass and allow for the measurement of an environmental contaminant i.e. Cr(6+). The ELDS was demonstrated to be statistically not different for Hooded and Non-Hooded models, compared to each other and the test dust; thus, it can be used indoors and outdoors in a variety of configurations to suit the user's needs.  相似文献   

5.
重金属生物有效性是评估重金属元素迁移性、生物可利用性和生态影响的关键参数。薄膜扩散梯度技术(DGT)是一种原位被动采样技术,因其具有原位富集性、形态选择性,可提供被监测物质在监测时间段内的平均浓度等优点,可作为生物对重金属摄取的模拟替代物对环境介质中重金属的生物可利用度进行预测,已被广泛应用于环境介质中重金属生物有效性的测定。研究主要介绍了DGT技术的原理、组成和特点,评述了其近年来在水体、土壤、沉积物中重金属生物有效态应用方面的新进展,提出了DGT技术未来要提高抗生物污染能力及寻找可与DGT技术联用的相关技术的观点。  相似文献   

6.
A novel passive water sampler for in situ sampling of antibiotics   总被引:1,自引:0,他引:1  
Passive water sampling has several advantages over active methods; it provides time-integrated data, can save on time and cost compared to active methods, and yield high spatial resolution data through co-deployment of simple, cheap units. However, one problem with many sampler designs in current use is that their uptake rates for trace substances of interest are flow-rate dependent, thereby requiring calibration data and other information to enable water concentrations to be derived from the mass per sampler. However, the 'family' of samplers employing the principle of diffusive gradients in thin films (DGT) provides an in situ means of quantitatively measuring labile species in aquatic systems without field calibration. So far, this technique has only been tested and applied in inorganic substances: metals, radionuclides, nutrients, etc. Design and applications of DGT to trace organic contaminants ('o-DGT') would be of widespread interest. This study describes the laboratory testing and performance characteristics of o-DGT, with the antibiotic sulfamethoxazole (SMX) as a model compound and XAD18 as the novel binding agent. o-DGT uptake of SMX increased with time and decreased with diffusion layer thickness, confirming the principle for SMX. XAD18 showed sufficiently high capacity for SMX for routine field applications. o-DGT measurement of SMX was independent of pH (6-9) and ionic strength (0.001-0.1 M) and not affected by flow rate once above static conditions. The diffusion coefficient of SMX in the sampler was measured using an independent diffusion cell and information is presented to allow temperature correction and derivation of aqueous concentrations from deployed samplers. The potential use of o-DGT for in situ measurement of pharmaceutical antibiotics is confirmed by this study and applications are briefly discussed.  相似文献   

7.
This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported elsewhere. The results, based on data from the three workplaces where lead was the major element present in the samples, are summarized here. A limit of detection and a limit of quantitation are provided. Analysis of some samples using a second analyzer with a different X-ray source technology indicated reasonable agreement for some metals (but this was not evaluated for lead). Provided it is only necessary to analyze the filters, most personal samplers will provide acceptable results when used with portable XRF analysis for lead around applicable limit values.  相似文献   

8.
A new water sample collection system was developed to improve representation of solids entrained in urban stormwater by integrating water-quality samples from the entire water column, rather than a single, fixed point. The depth-integrated sample arm (DISA) was better able to characterize suspended-sediment concentration and particle size distribution compared to fixed-point methods when tested in a controlled laboratory environment. Median suspended-sediment concentrations overestimated the actual concentration by 49 and 7% when sampling the water column at 3- and 4-points spaced vertically throughout the water column, respectively. Comparatively, sampling only at the bottom of the pipe, the fixed-point overestimated the actual concentration by 96%. The fixed-point sampler also showed a coarser particle size distribution compared to the DISA which was better able to reproduce the average distribution of particles in the water column over a range of hydraulic conditions. These results emphasize the need for a water sample collection system that integrates the entire water column, rather than a single, fixed point to properly characterize the concentration and distribution of particles entrained in stormwater pipe flow.  相似文献   

9.
Lipid-filled semipermeable membrane devices (SPMDs) are receiving increasing attention as passive, in situ samplers for the assessment of environmental pollutant exposure. Although SPMDs have been successfully used in a variety of field studies in surface waters, only a few studies have addressed their characteristics as groundwater samplers. In this study, the performance of the SPMDs for monitoring organic contaminants in groundwater was evaluated in a pilot field application in an area severely contaminated by chemical waste, especially by chlorinated hydrocarbons. The spatial distribution of hydrophobic groundwater contaminants was assessed using a combination of passive sampling with SPMDs and non-target semiquantitative GC-MS analysis. More than 100 contaminants were identified and semiquantitatively determined in SPMD samples. Along the 6 field sites under investigation, a large concentration gradient was observed, which confirms a very limited mobility of hydrophobic substances in dissolved form in the aquifer. The in situ extraction potential of the SPMD is limited by groundwater flow, when the exchange volume of well water during an exposure is lower than the SPMD clearance volume for the analytes. This study demonstrates that SPMDs present a useful tool for sampling and analyzing of groundwater polluted with complex mixtures of hydrophobic chemicals and provides guidance for further development of passive sampling technology for groundwater.  相似文献   

10.
This research evaluated the UNC passive aerosol sampler as a tool to measure particle mass concentrations and size distributions. The exposure scenario represented high concentrations and exposure periods of a few hours. Mass concentrations measured with the passive sampler were compared to concentrations measured using both a dichotomous sampler and an aerodynamic particle sizer (APS). In addition, the size distributions measured with the passive sampler were compared to those measured using the APS. Mass concentrations measured using the dichotomous sampler and the APS agreed well. The passive sampler tracked, but tended to overestimate, mass concentrations measured by the other two instruments. Size distributions measured with the passive sampler followed the general pattern of those measured using the APS. Overall, the passive sampler demonstrated both its utility and its limitations in these tests. The concentration measurements and size distributions found using passive samplers were more variable than those of the other instruments, but generally followed the data taken using the other methods. The advantages of low cost and ease of use offset the limitations in data quality with the passive sampler; these advantages are particularly welcome for sampling situations where aerosol properties vary over space or time.  相似文献   

11.
Chemical (polycyclic aromatic hydrocarbon - PAH and heavy metal) levels in stormwater and sediment samples collected from the London Orbital (M25) motorway drainage dry detention pond at Oxted, Surrey, UK were determined. Such chemicals are derived from vehicular combustion products and the wear and tear materials deposited onto the motorway surface. Gas chromatography-mass spectrometry (GC-MS) was used for the qualitative and quantitative determination of 16 USEPA priority PAHs in motorway drainage sediments. The GC-MS method, incorporating a solid phase extraction step, provides detection limits ranging from 0.17 to 0.41 mg kg(-1)(dry weight). Almost all of the 16 USEPA listed PAHs were detected. Phenanthrene, fluoranthene, pyrene, benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(a)pyrene and benzo(g,h,i)perylene (PAH numbers 5, 7, 8, 9, 10, 11, 13 and 16) were among the PAHs found at "higher" levels (ranging from 0.3-10.2 mg kg(-1), dry weight) in the sediment samples. PAH levels show little change along the motorway drainage silt trap (facility for reducing the levels of suspended particulate matter in the stormwater). PAH concentrations are considerably higher in the dry detention pond outflow interceptor. Statistical analysis showed that significant correlation coefficients (based on a t-test at the 95% confidence interval) were obtained between those PAHs found at high concentrations over all of the sampling sites. Several PAHs were dispersed beyond the treatment facility and accumulation in the sediment of the deer park resulted in levels ranging from 0.3-1.6 mg kg(-1), dry weight. These PAHs found beyond the treatment facility (in the local farm deer park) may contribute a serious health threat to farm animals or even fish in the aquatic environment. Heavy metal levels (V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo, Cd, Sb and Pb) of the drainage stormwater and sediments were determined by inductively coupled plasma mass spectrometry (ICP-MS), with quality control evaluation using two certified reference materials. Typical detection limits were found to be below 0.1 [micro sign]g l(-1) for stormwater and 0.005 mg kg(-1) for acid digested sediments. Raised heavy metal levels were found throughout the dry detention pond facility and only decrease when the stormwater is diluted following discharge into the river Eden. Statistical analysis also confirms that some significant correlations exist between various heavy metals and PAHs. However, no overall conclusive trend is found indicating that a particular PAH is deposited in sediment relative to a specific heavy metal/s. These results raise some serious concerns about the dispersion and accumulation of chemicals in the sediments of motorway stormwater drainage systems and the need for maintenance and clean-up of contaminated material from such systems.  相似文献   

12.
A new all season passive sampling system for monitoring O3 in the atmosphere has been developed in the laboratory and validated in the field. The unique features for this system include a newly designed passive sampler and a rain shelter, which allow the passive sampler to be installed in the field facing downwards. An equation associated with meteorological parameters is used to calculate the passive sampling rates. This system has been extensively tested in the lab (temperature from –18 to 20°C, relative humidity from 13 to 81%, and wind speed from 0.5 to 150 cm/s) and validated in the field in climates of all seasons. The accuracy of the ozone concentrations in the atmosphere obtained with the use of the new passive sampling system was higher than 85% compared to those obtained with continuous ozone analyzers. The new ozone passive sampling system can be used to measure ambient O3 concentrations ranging from 3 ppb to 1000 ppb based on one-day exposure and 0.1 ppb to 140 ppb for a monthly exposure period. It is also reasonable to conclude that the new passive sampling system can be used for eight-hour exposure study because of the low field blanks and high sampling rates.  相似文献   

13.
A passive sampling device, developed for personal monitoring of airborne dust levels in industry, has been tested as a site sampler in the urban environment. The device weighs approximately 15g and the essential sampling element is a small disc of electret material (polymer carrying a permanent electric charge). During use it captures particles by electrical attraction, at a rate that depends upon their electrical mobility, but which is independent of the rate at which air flows past the sampler. It collects measurable quantities of particulate, though the sample size tends to be small and correlation with results from conventional samples has not yet been established. Samplers have been exposed to urban particulate for periods of up to seven days, without the electret suffering unacceptable loss of electric charge. It has been shown to be potentially useful for long-term monitoring, a situation in which dispensing with a power source is particularly useful. Being small, the passive sampler is easy to hide or camouflage. It has potential for multiple simultaneous site sampling and for monitoring personal environmental exposure.  相似文献   

14.
Urban wastewater treatment leads to the generation of large quantities of biosolids. Accumulation of biosolids is a problem of environmental relevance due to the existence of heavy metals in the biosolids. Determination of total metal in biosolid provides information relating pollution levels. Determination of their mobilization capacity and behaviour in the environment is an important task. An experimental approach commonly used for studying the mobility, transport and bioavailability of metal in biosolids is the use of selective sequential extraction procedure. In the present study an attempt has been made to study the heavy metal properties in biosolid samples collected from urban wastewater treatment plants located at Mysore, Karnataka. Few heavy metals selected for the present study are cadmium, chromium, copper, iron, nickel and zinc. The concentration of these metals in biosolids and their partition in different fractions are studied. The speciation of metals based on the sequential extraction scheme was carried out. The concentration of heavy metals is lower than that established by European legislation. The residual fraction has the maximum percentage of heavy metals whereas, only a small fraction of heavy metals (Fe, Zn and Cd) are extracted in the most soluble fractions, exchangeable and carbonate fractions.  相似文献   

15.
Water quality in urban streams and stormwater systems is highly dynamic, both spatially and temporally, and can change drastically during storm events. Infrequent grab samples commonly collected for estimating pollutant loadings are insufficient to characterize water quality in many urban water systems. In situ water quality measurements are being used as surrogates for continuous pollutant load estimates; however, relatively few studies have tested the validity of surrogate indicators in urban stormwater conveyances. In this paper, we describe an observatory aimed at demonstrating the infrastructure required for surrogate monitoring in urban water systems and for capturing the dynamic behavior of stormwater-driven pollutant loads. We describe the instrumentation of multiple, autonomous water quality and quantity monitoring sites within an urban observatory. We also describe smart and adaptive sampling procedures implemented to improve data collection for developing surrogate relationships and for capturing the temporal and spatial variability of pollutant loading events in urban watersheds. Results show that the observatory is able to capture short-duration storm events within multiple catchments and, through inter-site communication, sampling efforts can be synchronized across multiple monitoring sites.  相似文献   

16.
A thin-walled silicone rubber hollow fibre membrane has been developed as a passive sampler. The inside of the tube is filled with an aqueous solution at an appropriate pH. The tube is sealed at both ends and then immersed in a water sample. In order for the ionizable permeating compounds to be trapped in the aqueous receiving phase, the pH is adjusted such that the compounds are ionized and trapped. The major advantages are its simplicity, low cost and high selectivity, since only ionizable organic compounds are trapped. Additionally, the sampler uses no organic solvent. By adjusting the pH of the acceptor phase, it is possible to control the extraction process and whether the sampler is used in the kinetic or equilibrium regime. Since it is very selective, no further clean-up of the extract is required. The membrane assisted passive sampler has been tested for extraction of chlorophenols under laboratory conditions. The extraction process was found to be linear over a 72 h sampling period. Selectivity of the passive sampler in river water was demonstrated and the extraction process was independent of sample concentration, even at lower concentration levels of analytes. However, the sample matrix in some river water samples led to incomplete trapping, thereby reducing the amount trapped in the acceptor phase. Detection limits (three times signal to noise ratio) were dependant on sample matrix and type of detection system and ranged from 0.05 microg L(-1) to about 1 microg L(-1) with a UV photodiode detector in water samples from one river and 1.0 microg L(-1) to 20 microg L(-1) in another but with an ordinary UV detector. The enrichment factors in river water were 28 for 2-chlorophenol and 44 for 2,4-dichlorophenol over a 72 h sampling period. 4-chlorophenol was poorly extracted and its enrichment factor was 3.  相似文献   

17.
Suspended solids either as total suspended solids (TSS) or suspended sediment concentration (SSC) is an integral particulate water quality parameter that is important in assessing particle-bound contaminants. At present, nearly all stormwater runoff quality monitoring is performed with automatic samplers in which the sampling intake is typically installed at the bottom of a storm sewer or channel. This method of sampling often results in a less accurate measurement of suspended sediment and associated pollutants due to the vertical variation in particle concentration caused by particle settling. In this study, the inaccuracies associated with sampling by conventional intakes for automatic samplers have been verified by testing with known suspended sediment concentrations and known particle sizes ranging from approximately 20 μm to 355 μm under various flow rates. Experimental results show that, for samples collected at a typical automatic sampler intake position, the ratio of sampled to feed suspended sediment concentration is up to 6600% without an intake strainer and up to 300% with a strainer. When the sampling intake is modified with multiple sampling tubes and fitted with a wing to provide lift (winged arm sampler intake), the accuracy of sampling improves substantially. With this modification, the differences between sampled and feed suspended sediment concentration were more consistent and the sampled to feed concentration ratio was accurate to within 10% for particle sizes up to 250 μm.  相似文献   

18.
A field monitoring network was set up within the Stamford canal watershed in 1989 to study both the quantitative and qualitative aspects of storm runoff from this urbanised catchment. The data acquisition equipment comprised a continuous recording rain gauge, a water level recorder and an automatic water sampler capable of sampling storm runoff at preset intervals during rainfall events. Water samples were collected after each storm and laboratory tests were carried out on the physical and chemical properties of the storm water. Preliminary findings on the temporal variations of stormwater quality during single storms and the effects of antecedent dry weather period on the quality are presented. The average ranges of some of the significant quality parameters found in the storm runoff were also established. The quality of storm runoff from the catchment under study was found to be of an acceptable level and could potentially be developed as a water catchment area.  相似文献   

19.
A rapid, empirical method is described for estimating weekly AOT40 from ozone concentrations measured with passive samplers at forest sites. The method is based on linear regression and was developed after three years of measurements in Trentino (northern Italy). It was tested against an independent set of data from passive sampler sites across Italy. It provides good weekly estimates compared with those measured by conventional monitors (0.85 ≤R(2)≤ 0.970; 97 ≤ RMSE ≤ 302). Estimates obtained using passive sampling at forest sites are comparable to those obtained by another estimation method based on modelling hourly concentrations (R(2) = 0.94; 131 ≤ RMSE ≤ 351). Regression coefficients of passive sampling are similar to those obtained with conventional monitors at forest sites. Testing against an independent dataset generated by passive sampling provided similar results (0.86 ≤R(2)≤ 0.99; 65 ≤ RMSE ≤ 478). Errors tend to accumulate when weekly AOT40 estimates are summed to obtain the total AOT40 over the May-July period, and the median deviation between the two estimation methods based on passive sampling is 11%. The method proposed does not require any assumptions, complex calculation or modelling technique, and can be useful when other estimation methods are not feasible, either in principle or in practice. However, the method is not useful when estimates of hourly concentrations are of interest.  相似文献   

20.
A sampler was needed for a spatial and temporal study of microbial and chemical stratification in a large swine manure lagoon that was known to contain zoonotic bacteria. Conventional samplers were limited to collections of surface water samples near the bank or required a manned boat. A new sampler was developed to allow simultaneous collection of multiple samples at different depths, up to 2.3 m, without a manned boat. The sampler was tethered for stability, used remote control (RC) for sample collection, and accommodated rapid replacement of sterile tubing modules and sample containers. The sampler comprised a PVC pontoon with acrylic deck and watertight enclosures, for a 12 VDC gearmotor, to operate the collection module, and vacuum system, to draw samples into reusable autoclavable tubing and 250-mL bottles. Although designed primarily for water samples, the sampler was easily modified to collect sludge. The sampler held a stable position during deployment, created minimal disturbance in the water column, and was readily cleaned and sanitized for transport. The sampler was field tested initially in a shallow fresh water lake and subsequently in a swine manure treatment lagoon. Analyses of water samples from the lagoon tests showed that chemical and bacterial levels, pH, and EC did not differ between 0.04, 0.47, and 1.0 m depths, but some chemical and bacterial levels differed between winter and spring collections. These results demonstrated the utility of the sampler and suggested that future manure lagoon studies employ fewer or different depths and more sampling dates.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏