共查询到20条相似文献,搜索用时 12 毫秒
1.
Fence for traffic noise control sometimes causes adverse effect on air pollution. Thus in this study, performance of porous fence as a tool for control of both air pollution and noise pollution was evaluated. A two-dimensional numerical model for flow and pollutant concentration and an analytical model for traffic noise were utilized in the analysis of a double-decked road structure with fences only at ground (Case 1) and at both ground and upper deck (Case 2). Porous fences were assumed only at the ground level since the solid fences at the upper deck usually leads to desirable result on air pollution. Effects of the variable porosity on air quality and noise level near road were evaluated. Obtained results showed: (1) flow pattern in leeward of fence was drastically changed at 40–50% porosity in Case 1 and 50% in Case 2. The porosity larger than 40% excluded presence of a circulation behind the fence. (2) Effect of porous fence on air pollution was different in Cases 1 and 2. In Case 1, the porous fence generally resulted in the reduction of air pollution at the ground level; on the other hand, in Case 2, it rather led to increase of the concentration. (3) Traffic noise level was also largely changed by the porosity of the fence; an example of simultaneous evaluation of the effects of porous fence on both air and noise pollution in Case 1 showed that the fence of 60% porosity leads to reduction of air pollution by 20% compared with solid fence case, and reduction of noise pollution by 4–6% in dB compared with no fence case, at l m high and 10 m from the road. 相似文献
2.
This study compared three forecasting models based on the mean absolute percentage errors (MAPE) of their accuracy in forecasting
air pollution in a traffic tunnel: the Grey model (GM), the combination model used four sample point and five sample point
prediction with GM (1,1)(GM(1,1)4 + 5), and the modified grey model (MGM). An MGM was combined using the four points of the original sequence using the original
grey prediction GM (1,1) for short-term forecasting. The proposed method cannot only enhance the prediction accuracy of the
original grey model, but can also solve the jump data forecasting problem something for which the original grey model is inappropriate.
The MAPE was applied to the models, and the MGM found the proposed method to be simple and efficient. The MAPE of MGM, calculated
over 3 h of forecasts, were as follows: 10.12 (Upwind), 10.07 (Middle) and 7.68 (Downwind) for CO; 10.79 (Upwind), 6.05 (Middle)
and 5.98 (Downwind) for NO
x
, and 11.67 (Upwind), 7.32 (Middle) and 4.56 (Downwind) for NMHC. The MGM model results reveal that the combined forecasts
can significantly decrease the overall forecasting error. Results of this demonstrate that MGM can accurately forecast air
pollution in the Kaohsiung Chung–Cheng Tunnel. 相似文献
3.
The winters in megacity Delhi are harsh, smoggy, foggy, and highly polluted. The pollution levels are approximately two to
three times those monitored in the summer months, and the severity is felt not only in the health department but also in the
transportation department, with regular delays at airport operations and series of minor and major accidents across the road
corridors. The impacts felt across the city are both manmade (due to the fuel burning) and natural (due to the meteorological
setting), and it is hard to distinguish their respective proportions. Over the last decade, the city has gained from timely
interventions to control pollution, and yet, the pollution levels are as bad as the previous year, especially for the fine
particulates, the most harmful of the criteria pollutants, with a daily 2009 average of 80 to 100 μg/m3. In this paper, the role of meteorology is studied using a Lagrangian model called Atmospheric Transport Modeling System
in tracer mode to better understand the seasonality of pollution in Delhi. A clear conclusion is that irrespective of constant
emissions over each month, the estimated tracer concentrations are invariably 40% to 80% higher in the winter months (November,
December, and January) and 10% to 60% lower in the summer months (May, June, and July), when compared to annual average for
that year. Along with monitoring and source apportionment studies, this paper presents a way to communicate complex physical
characteristics of atmospheric modeling in simplistic manner and to further elaborate linkages between local meteorology and
pollution. 相似文献
4.
Temporal and spatial variations of the quality of ambient air in the Kingdom of Bahrain during 2007 总被引:3,自引:0,他引:3
The main objective of the present investigation is to study the temporal and spatial variations of the quality of ambient air in the Kingdom of Bahrain. The non-parametric Kruskal-Wallis (KW) test showed significant spatial variations and interactions of spatial-temporal among five mobile monitoring stations for 11 air pollutants. The Mann Whitney (MW) test demonstrated the seasonality of spring over winter for the PM(10), PM(2.5), NO(2), CO and p-xylene, the seasonality of winter over spring for O(3), and no significant seasonal variation for NH(3), benzene, SO(2), toluene and H(2)S. It is concluded that emissions from automobile exhaust, industrial and developmental projects are responsible for the spatial air pollution, and that air temperature is the controlling factor for the seasonal variations. 相似文献
5.
大连市在加强环境立法执法、老污染治理、新建项目管理的同时,通过进行区域总量控制、调整产业结构和工业布局以及对城市环境的综合整治等多种方法和手段,使城市环境空气质量明显改善. 相似文献
6.
Kin-Che Lam Weichun Ma Pak Kin Chan Wing Chi Hui King Lam Chung Yi-tak Teresa Chung Chun Yin Wong Hui Lin 《Environmental monitoring and assessment》2013,185(12):9683-9695
This paper reports on a study which explored the possible relationship between road traffic noisescape and urban form in Hong Kong. A total of 212 residential complexes from 11 contrasting urban forms were sampled, and their noise levels assessed both at dwelling and neighbourhood scales by noise mapping. Its findings indicate that residential complexes with different urban forms have significantly different noisescape attributes. There is a strong correlation between the noise characteristics and morphological indicators at the dwelling scale. A less obstreperous noisescape is associated with urban forms with lower road and building densities, and with building arrangements which provide self-noise screening. These findings suggest that urban form is an influential determinant of the noisescape in the urban environment, and they point to the need to rethink the conventional approach to managing the urban acoustic environment. 相似文献
7.
Dibyendu Banerjee Partha Pratim Das Anjan Foujdar 《Environmental monitoring and assessment》2014,186(5):2885-2893
There is an established evidence that exposure to high levels of road traffic noise is associated with elevated risk of coronary heart disease (CHD). The results however have been heterogeneous and mostly inconclusive. The present investigation aimed to examine this association in adult subjects, with a secondary aim of identifying potentially vulnerable sub-populations. Similar studies have never been reported from Indian population. For exposure assessment, the time-weighted road traffic noise indicator, L den, was used as a continuous and categorical predictor. A cross-sectional study was designed, and sociodemographic and lifestyle- and health-related characteristics were recorded for 909 (533 females and 376 males) subjects aged 18–80 years. The respondents living in areas with L den?<?60 dB(A) were designated as the reference group. Odds for self-reported CHD in relation to traffic noise exposure were estimated by univariate and multifactorial logistic regression with adjustments for potential confounders and effect modifiers. The adjusted odds ratio (OR) for self-reported CHD was 1.72 (95 % CI 1.36–2.19) per 5 dB(A) increase of L den (range 55–80 dB(A)). A gender-related risk difference was observed among male (OR 1.47 (1.07–2.02)) and female (OR 1.83 (1.27–2.65)) respondents. A stronger effect for subjects in the age group 55–64 years old was found, with age, residence period, body mass index, and self-reported stress being significant confounders. This study suggests epidemiological evidence that exposure to road traffic noise of L den?>?65 dB(A) may be associated with occurrence of CHD in adult subjects. A trend was observed indicating increasing risk with higher exposure levels. The study results are also suggestive of higher risk of outcome among those with other chronic ailments (diabetes, pulmonary, or renal issues) and residing in the same location in excess of 15 years. Orientation of bedroom windows was identified as a significant effect modifier. 相似文献
8.
This study investigated the effect of odour on multisensory environmental evaluations of road traffic. The study aimed to answer: (1) Does odour have any effect on evaluations on noise, landscape and the overall environment? (2) How different are participants' responses to odour stimuli and are these differences influential on the evaluations? Experimental scenarios varied in three Traffic levels, three Tree screening conditions and two Odour presence conditions were designed, and presented to participants in virtual reality. Perceived Loudness, Noise Annoyance, Landscape Quality and Overall Pleasantness of each scenario were evaluated and the results were analysed. It shows that Odour presence did not have significant main effect on any of the evaluations, but has significant interactions with Traffic level on Noise Annoyance and with Tree screening on Landscape Quality, indicating the potential of odour to modulate noise and visual landscape perceptions in specific environmental content. Concerning participants' responses to odour stimuli, large differences were found in this study. However, the differences did not seem to be influential on environmental evaluations in this study. Larger samples of participants may benefit this study for more significant results of odour effect. 相似文献
9.
Rakkestad KE Dye CJ Yttri KE Holme JA Hongslo JK Schwarze PE Becher R 《Journal of environmental monitoring : JEM》2007,9(12):1419-1425
Phthalates are found in numerous consumer products, including interior materials like polyvinyl chloride (PVC). Several studies have identified phthalates in indoor air. A recent case-control study demonstrated associations between allergic symptoms in children and the concentration of phthalates in dust collected from their homes. Here we have analyzed the content of selected phthalates in particulate matter (PM): PM(10) and PM(2.5) filter samples collected in 14 different indoor environments. The results showed the presence of the phthalates di-n-butyl phthalate (DBP), butyl benzyl phthalate (BBP), dicyclohexyl phthalate (DCHP) and diethyl hexyl phthalate (DEHP) in the samples. The dominating phthalate in both PM(10) and PM(2.5) samples from all locations was DBP. More than a 10-fold variation in the mean concentration of total phthalates between sampling sites was observed. The highest levels of total phthalates were detected in one children's room, one kindergarten, in two primary schools, and in a computer room. The relative contribution of total phthalates in PM(10) and PM(2.5) was 1.1 +/- 0.3% for both size fractions. The contribution of total phthalates in PM(2.5) to total phthalates in PM(10) ranged from 23-81%, suggesting different sources. Of the phthalates that were analyzed in the PM material, DBP was found to be the major phthalate in rubber from car tyres. However, our analyses indicate that tyre wear was of minor importance for indoor levels of both DBP as well as total phthalates. Overall, these results support the notion that inhalation of indoor PM contributes to the total phthalate exposure. 相似文献
10.
Indoor air quality in university environments 总被引:1,自引:0,他引:1
Mara Di Giulio Rossella Grande Emanuela Di Campli Soraya Di Bartolomeo Luigina Cellini 《Environmental monitoring and assessment》2010,170(1-4):509-517
This study evaluates the airborne microflora in research laboratories of the University of Chieti (Italy). A quali-quantitative evaluation of the index microbial air contamination was performed using the settle plate method. The microbial air contamination was evaluated during 6 months in three university buildings (A, B, and C). Nutrient agar plates were exposed, monthly, for 1 h at the morning and the afternoon to evaluate the colony forming units per plate per hour. Together with the quantitative analysis, the most frequent bacterial and fungal colonies isolated were also characterized. Moreover, in each sampling, the number of the occupants in each room was recorded to evaluate a possible relationship with the microbial pollution. The microbial concentration was always within the limit values defined for these environments. Buildings A and C displayed a seasonal fluctuation of airborne microflora with the increase in microbial concentration in the warmer season (April to June) in respect to the colder period (October to December). The most common microorganisms detected in the indoor air of the examined buildings were Gram-positive bacteria, belonged to the genera Staphylococcus, Bacillus, and Actinomyces. Data presented here underline the useful monitoring of the research university laboratories also emphasizing the effectiveness of the settle plate method. 相似文献
11.
R. San José J. Cortés J. F. Prieto R. M. González 《Environmental monitoring and assessment》1998,52(1-2):203-212
The ANA Air Quality Model (ANA stands for Atmospheric Mesoscale Numerical Pollution Model for Regional and Urban Areas) has been applied over Madrid during a five day period in June, 1995. The domain is 80 × 100 km2 and the spatial resolution is 2000 m. The ANA system is driven by a meteorological model REMEST and it includes a detailed emission model for anthropogenic and biogenic sources with 250 m spatial resolution and 60 minutes temporal resolution. Different deposition processes are used such as the Wesely (1989) and Erisman et al. (1994) resistance approaches and the simple aerodynamic resistance. The photochemical processes and the general chemistry is based on the CBM-IV mechanism for the organic compounds and solved by the SMVGEAR method (CHEMA module).The model uses 14 different landuse types which are obtained by using the REMO module which uses the information provided by the LANDSAT-5 satellite image over the domain. The emission module EMIMA takes into account the point, line and area emissions over the domain. Special importance is given to the biogenic emissions which are obtained by using the satellite landuse classification for caducous, perenneal and mixed terrain. The emission module considers the EPA and CORINAIR emission factors. The results show an accurate prediction of the ozone maxima for the five days and also the general pattern of the ozone observed data. The five day simulation is characterized by a local low pressure over the Madrid Area and high pressures over Spain and West of Europe. The ozone surface patterns show the diurnal cycle and the maxima concentrations up to 140-160 ppb for suburban areas during afternoon hours. The general performance of the model is considered quite good. The computer power requirements continue to be very high for standard workstations. Future progress on parallel platforms should improve considerably the computer time requirements. 相似文献
12.
Giakoumi A Maggos T Michopoulos J Helmis C Vasilakos Ch 《Environmental monitoring and assessment》2009,152(1-4):83-95
PM(2.5) and VOCs (benzene, toluene, m-p-o-xylenes) concentrations were measured in an urban and a suburban site in Athens, Greece, during the period between April and November 2004. This period, which is considered to be the warmer period in Greece, is characterized by the development of sea-breeze over the Attica Basin. Additionally strong Northern, North-eastern winds called "The Etesians", predominate during the summer months (July-August), acting positively to the dispersion of pollutants. In this campaign, 24 days with sea-breeze development were observed, 15 days with northern winds, 6 days with southern winds while the rest of the days presented no specific wind profile. Maximum concentrations of PM(2.5), VOCs and nitrogen oxides, were detected during the days with sea-breeze, while minimum concentrations during the days with northern winds. Ozone was the only pollutant that appeared to have higher concentrations in the background site and not in the city centre, where benzene presented strong negative correlation with ozone, indicating the photochemical reaction of hydrocarbons that lead to the ozone formation. The BTX ratios were similar for both sites and wind profiles, indicating common sources for those pollutants. T/B ratio ranged in low levels, between 3-5 for site A and 2-5 for site B, suggesting vehicles emissions as the main sources of volatile compounds. Finally, the strong correlations of PM(2.5) and benzene concentrations, between the two sampling sites, indicate that both the city centre and the background site, are affected by the same sources, under common meteorological conditions (sea-breeze, northern winds). 相似文献
13.
Attitudinal response towards road traffic noise in the industrial town of Asansol, India 总被引:1,自引:0,他引:1
Banerjee D Chakraborty SK Bhattacharyya S Gangopadhyay A 《Environmental monitoring and assessment》2009,151(1-4):37-44
The major objective of the investigation was to evaluate the road traffic noise and its likely impacts on the local community of Asansol city (West Bengal, India) by monitoring and modeling. The attitudinal response of local population due to existing vehicular noise is presented in the paper. Noise and Attitudinal Survey was conducted at 25 locations. A total of 869 individuals were surveyed. The relationship between traffic noise levels and annoyance was studied using correlation, linear and multiple linear regressions analysis. The average L(dn) value was 73.28 +/- 8.51 dB(A) (55.1-87.3); The Traffic Noise Index (TNI) was 80.62 +/- 15.88 dB(A) (49.4-115.8). The mean value of percent of population Highly Annoyed (%HA) due to road traffic noise was 26.50 +/- 3.37 (19.44-33.2), whereas the mean dissatisfaction score (MDS) was 2.96 +/- 0.90 (1.04-4.45). Annoyance modeling was also performed based on field data. It can be said that Noise values gives desirable annoyance predicting values in comparison to vehicular data. 相似文献
14.
Chun-Chin Wang Guor-Cheng Fang Chao-Hung Kuo 《Environmental monitoring and assessment》2010,161(1-4):1-9
Bioaerosols are a type of suspended sediments that contribute to poor air quality in Taiwan. Bioaerosols include allergens such as: fungi, bacteria, actinomycetes, arthropods and protozoa, as well as microbial products such as mycotoxins, endotoxins and glucans. When allergens and microbial products are suspended in the air, local air quality will be influenced adversely. In addition, when the particle size is small enough to pass through the respiratory tract entering the human body, the health of the local population is also threatened. Therefore, the purpose of this study is to attempt to understand the concentration and types of bacteria and the bacteria numbers for various particle size ranges during a study period of June 2005 to February 2006 in Taichung City, Central Taiwan. The results indicate that the total average bacterial concentration by using NA medium incubated for 48 h were 8.0 × 102, 1.4 × 103, 2.4 × 103 and 1.3 × 103, 1.9 × 103, 3.5 × 103 cfu/m3 for CMES, TRIPS and RFS sampling sites during the daytime and nighttime period of June 2005 to February 2006. Moreover, the total average bacterial concentration by using R2A medium incubated for 48 h were 8.5 × 102, 1.5 × 103, 2.2 × 103 and 1.2 × 103, 1.7 × 103, 2.5 × 103 cfu/m3 for CMES, TRIPS and RFS sampling sites the daytime and nighttime during the same sampling period. The total average bacteria concentration was the same in either NA or R2A medium for the same sampling times or sites. The total average bacterial concentration was higher in daytime period than that of nighttime period for CMES, TRIPS and RFS sampling sites. The high average bacterial concentration was found in the particle size range of 0.53–0.71 mm (average bioaerosol size was in the range of 2.1–4.7 μm) for each sampling site. Also, 20 kinds of bacteria exceeded levels for each sampling site and were classified as according to shape: rod, coccus and filamentous. 相似文献
15.
拉萨市环境空气质量与气象特征分析 总被引:11,自引:0,他引:11
分析了拉萨市环境空气质量及其拉萨市的地理位置、地形地貌和气候特征的关系。研究结果表明 ,自然沙尘是拉萨市环境空气质量的主要自然源。月降尘量与降水、大风等有明显的相关关系。加快拉萨地区生态环境建设 ,增加植被覆盖率 ,减少沙源是改善拉萨市环境空气质量的关键 相似文献
16.
17.
A new method for multi-objective optimization of air quality monitoring systems based on satellite remote sensing of the troposphere
is described in this work. The technique uses atmospheric turbidity as surrogate for air pollution loading. Through inverse
chemical modeling and ancillary information the respective patterns of primary gaseous and particle pollutants are inferred.
The optimization algorithm uses the resulting maps of ambient air pollution as input. It focuses on the gain of information
with regard to human exposure to high pollution, potential impact on cultural heritage, compliance to ambient air quality
standards, monitoring key point and area source emissions, as well as on the associated cost. Application of the method in
Brescia, Italy showed its significant potential for improving the cost-effectiveness of air quality monitoring networks at
the urban and regional scales. 相似文献
18.
Chatterton TJ Woodfield NK Beattie CI Longhurst JW 《Journal of environmental monitoring : JEM》2004,6(10):849-853
In 1997, the UK government instigated the practice of Local Air Quality Management (LAQM) in the UK. This process is based on local authorities undertaking Review and Assessments of air quality within their areas. The first round of Review and Assessments have now been completed and represents the most extensive and coordinated analysis of air pollution ever undertaken in the UK, and probably in Europe. This paper takes a broad look at the outcomes of this process so far and identifies some of the key areas where lessons have/can be learnt both about patterns of air pollution in the UK and about the framework for investigating these that has been implemented under the LAQM regime. The process has led to a much higher number of local authorities finding problems with air pollution than initially expected. It has also challenged many assumptions about the significance of various pollutants and their sources. 相似文献
19.
Public elevators are an essential requirement in modern high-rise buildings. However, the confined, crowded interior of an elevator provides an ideal breeding ground for all manners of biological aerosols. Consequently, when using an elevator at a university in Taiwan as the research target, this study performs an experimental investigation into the effectiveness of hand-sprayed gaseous chlorine dioxide as a disinfection agent. The air quality before and after disinfection is evaluated by measuring the bioaerosol concentrations of bacteria and fungi, respectively. The average background levels of bacteria and fungi before disinfection are found to be 635.7?±?469.6 and 1296.8?±?966.6 colony-forming unit (CFU)/m3, respectively. Following disinfection, the bacteria and fungi concentrations reduced by an average of 35 and 25 %, respectively. The multivariate analysis of variance (MANOVA) results showed that the residual bacteria and fungi concentration levels were determined primarily by the number of individuals within the elevator and the elapsed time following disinfection. In general, the present results show that given a maximum of five individuals within the elevator, a disinfection schedule of once every 40 min is sufficient to reduce the bioaerosol concentrations of bacteria and fungi to the levels specified by the Taiwan Environmental Protection Agency (EPA). 相似文献
20.
R. A. Field J. R. Brown M. E. Goldstone J. N. Lester R. Perry 《Environmental monitoring and assessment》1996,43(2):101-116
Results of intermittent monitoring of six aromatic hydrocarbons (benzene, toluene, ethyl-benzene, m-xylene, p-xylene and o-xylene), carbon monoxide and oxides of nitrogen over a thirteen year period at a site in central London (Exhibition Road) are presented. Four monitoring regimes were undertaken; namely, 1979, 1982/83, 1986/87 and 1991/92. The summertime daytime mean ambient concentrations of the measured parameters at this site are presented. The reported concentrations show a reduction from 1979 to 1992 by approximately a factor of two, despite national increases in motor fuel consumption and the volume of traffic. Relevant European Community legislation covering emissions from motor-vehicles are outlined and comparisons are made with emissions from motor vehicles predicted from the UK national inventory. The importance of the frequency of measurements was also noted. 相似文献