首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Geology has been highlighted by a number of authors as a key factor in high indoor radon levels. In the light of this, this study examines the application of seasonal correction factors to indoor radon concentrations in the UK. This practice is based on an extensive database gathered by the National Radiological Protection Board over the years (small-scale surveys began in 1976 and continued with a larger scale survey in 1988) and reflects well known seasonal variations observed in indoor radon levels. However, due to the complexity of underlying geology (the UK arguably has the world's most complex solid and surficial geology over the shortest distances) and considerable variations in permeability of underlying materials it is clear that there are a significant number of occurrences where the application of a seasonal correction factor may give rise to over-estimated or under-estimated radon levels. Therefore, the practice of applying a seasonal correction should be one that is undertaken with caution, or not at all. This work is based on case studies taken from the Northamptonshire region and comparisons made to other permeable geologies in the UK.  相似文献   

2.
To identify the most applicable technology for the short-term assessment of domestic radon levels, comparative assessments of a number of integrating detector types, including track-etch, electret and activated charcoal were undertaken. Thirty-four unremediated dwellings in a high-radon area were monitored using track-etch detectors exposed for one-month and three-month periods. In parallel, one-week measurements were made in the same homes at one-month intervals, using co-located track-etch, charcoal and electret detectors exposed simultaneously, while three of the homes were also monitored by continuous-sampling detectors at hourly intervals over extended periods. Calibration of dose-integrating devices against each other and against continuous-monitoring systems confirmed good responsivity and linearity. Although track-etch, charcoal and electret devices are suitable in principle for one-week measurements, zero-exposure offset and natural radon variability cause many one-week results to be equivocal, necessitating repetition of the measurement. One-week exposures can be reliable indicators in low-radon areas or for new properties, but in high-radon areas, the use of three-month exposures is indicated. This analysis also established confidence limits for short-term measurements.  相似文献   

3.
In this paper, a simple model for analysing variability in radon concentrations in homes is tested. The approach used here involves two error components, representing additive and multiplicative errors, together with variation between-houses. We use a Bayesian approach for our analysis and apply this model to two datasets of repeat radon measurements in homes; one based on 3-month long measurements for which the original measurements were close to the current UK Radon Action Level (200 Bq m−3), and the other based on 6-month measurement data (from regional and national surveys), for which the original measurements cover a wide range of radon concentrations, down to very low levels. The model with two error components provides a better fit to these datasets than does a model based on solely multiplicative errors.  相似文献   

4.
Radon gas contributes a significant fraction of the natural background radiation dose, and in some areas raised levels are found in buildings. both homes and the workplace. Different UK Action Levels apply to homes and the workplace. because of the diurnal variation of radon. This study reviews the results for a number of hospitals throughout England and Wales. and suggests that the likelihood of finding raised radon levels is similar in the workplace and homes in the same area. Radon measurements and consequent remediation of any raised levels are appropriate in all workplaces in radon Affected Areas with over 5% of houses above the UK domestic Action Level of 200 Bq m(-3).  相似文献   

5.
Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored continuously throughout a 5-week period during which active sub-slab depressurisation remediation measures were installed. Remediation of the property was accomplished successfully, with both the mean radon levels and the diurnal variability greatly reduced both upstairs and downstairs. Following remediation, upstairs and downstairs radon concentrations were 33% and 18% of their pre-remediation values respectively: the mean downstairs radon concentration was lower than that upstairs, with pre- and post-remediation values of the upstairs/downstairs concentration ratio, R(U/D), of 0.81 and 1.51 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 h or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure difference prior to remediation; this correlation disappears following remediation. Overall, these observations provide further evidence that radon concentration levels within a dwelling are not necessarily wholly determined by the effects of soil-gas advection, and further support the suggestion that, depending on the precise content of the building materials, upstairs radon levels, in particular, may be dominated by radon exhalation from the walls of the dwelling, especially in areas of low soil-gas radon.  相似文献   

6.
An investigation of radon levels in the caves of Creswell Crags, Derbyshire, an important Site of Special Scientific Interest (SSSI) shows that the Lower Magnesian Limestone (Permian) caves have moderate to raised radon gas levels (27-7800 Bq m(-3)) which generally increase with increasing distance into the caves from the entrance regions. This feature is partly explained in terms of cave ventilation and topography. While these levels are generally below the Action Level in the workplace (400 Bq m(-3) in the UK), they are above the Action Level for domestic properties (200 Bq m(-3)). Creswell Crags has approximately 40,000 visitors per year and therefore a quantification of effective dose is important for both visitors and guides to the Robin Hood show cave. Due to short exposure times the dose received by visitors is low (0.0016 mSv/visit) and regulations concerning exposure are not contravened. Similarly, the dose received by guides is fairly low (0.4 mSv/annum) due in part to current working practice. However, the risk to researchers entering the more inaccessible areas of the cave system is higher (0.06 mSv/visit). This survey also investigated the effect of seasonal variations on recorded radon concentration. From this work summer to winter ratios of between 1.1 and 9.51 were determined for different locations within the largest cave system.  相似文献   

7.
The results of radon activity recorded in 70 dwellings of Nurpur area, Kangra district, Himachal Pradesh, India are reported. LR-115 Type 2 films in the bare mode were exposed for four seasons of three months each covering a period of one year for the measurement of indoor radon levels. The calibration constant of 0.020 tracks cm(-2) d(-1) per Bq m(-3) has been used to express radon activity in Bq m(-3). The annual average indoor radon concentrations in 17 different villages of the area are found to vary from 168+/-46 to 429+/-71. Most of the indoor radon values lie in the range of action levels (200-600 Bq m(-3)) recommended by International Commission on Radiological Protection.  相似文献   

8.
In the UK, excessive levels of radon gas have been detected in domestic housing. Areas where 1% of existing homes were found to be over the Action Level of 200 Bq · m 3 were declared to be Radon Affected Areas. Building Regulations have been introduced which require that, for areas where between 3% and 10% of existing houses are above the Action Level, new homes should be built with basic radon protection using a membrane, and that, where 10% or more of existing homes exceed this level, new homes should be built with full radon protection.Initially these affected areas followed administrative boundaries, known as Counties. However, with increasing numbers of measurements of radon levels in domestic homes recorded in the national database, these areas have been successively refined into smaller units – 5 km grid squares in 1999, down to 1 km grid squares in 2007.One result is the identification of small areas with raised radon levels within regions where previously no problem had been identified. In addition, some parts of areas that were previously considered radon affected are now considered low, or no, risk. Our analysis suggests that the net result of improved mapping is to increase the number of affected houses. Further, the process is more complex for local builders, and inspectors, who need to work out whether radon protection in new homes is appropriate.Our group has assessed the cost-effectiveness of radon remediation programmes, and has applied this analysis to consider the cost-effectiveness of providing radon protection in both new and existing homes. This includes modelling the potential failure rate of membranes, and whether testing radon levels in new homes is appropriate. The analysis concludes that it is more cost effective to provide targeted radon protection in high radon areas, although this introduces more complexity.The paper also considers the trend in housing to a greater proportion of apartments, the regional variations in types of housing and the decreasing average number of occupants in each dwelling, and concludes that data and methods are now available to respond to the health risks of radon at a local level, in keeping with a general initiative to prioritise responses to health and social welfare issues at a more local level.  相似文献   

9.
Domestic radon levels in parts of the United Kingdom are sufficiently high as to increase the risk of lung-cancer among residents. Public health campaigns in the county of Northamptonshire, a designated radon Affected Area with 6.3% of homes having average radon levels in excess of the UK Action Level of 200 Bq m(-3), have encouraged householders to test for radon and then, if indicated to be necessary, to carry out remediation in their homes. These campaigns have been only partially successful, since to date only 40% of Northamptonshire houses have been tested, and only 15% of those householders finding raised levels have proceeded to remediate. Those who remediate have been shown to have smaller families, to be older, and to include fewer smokers than the average population, suggesting that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-2005, the NHS Stop-Smoking Services in Northamptonshire assisted 2847 smokers to quit to the 4-week stage, the 15% (435) of these 4-week quitters remaining quitters at 1year forming the subjects of a retrospective study considering whether smoking cessation campaigns contribute significantly to radon risk reduction. Quantitative assessment of the risk of lung-cancer among the study population, from knowledge of the individuals' age, gender, and smoking habits, together with the radon levels in their homes, demonstrates that smoking cessation programmes have significant added value in reducing the incidence of lung-cancer in radon Affected Areas, and contribute a substantially greater health benefit at a lower cost than the alternative strategy of reducing radon levels in the smokers' homes, while they remain smokers. Both radon remediation and smoking cessation programmes are very cost effective in Northamptonshire, with smoking cessation being significantly more cost effective, and these are potentially valuable programmes to drive health improvements through promotion of the uptake or environmental management for radon in the home.  相似文献   

10.
Radon gas can be present within buildings at sufficiently high levels that it becomes a health risk. Such levels can be reduced, and so radon remediation programmes in the home in UK Affected Areas should result in reduced risks to the population. This paper considers the benefits and costs of the domestic radon remediation programme in Northamptonshire, UK, and considers the implications of the choice of Action Level, in view of the adoption of different levels in many countries. A programme with a higher Action Level will cost less, and target those most at risk, but will be less cost effective. In addition, a higher Action Level leaves a higher residual dose and risk to the remaining population. Such doses are higher than and inconsistent with the radiation dose limits for the general public in the EU Basic Standards Directive.  相似文献   

11.
This paper reports on radon concentrations in dwellings from fifty different locations of India. The incorporated data were obtained using the passive solid state nuclear track detector technique. The estimated geometric mean value for India is 67.1 Bq m(-3). Chuadanga in Bangladesh had the lowest observed indoor radon concentration of 27.3 Bq m(-3) and Una in the northern part of India had the highest concentration of 281.5 Bq m(-3). This paper discusses the national geometrical mean value in terms of the national geometric mean values of other countries and also in terms of the geological influence. The estimated indoor radon levels are compared with the indoor radon levels as recommended by the International Commission on Radiation Protection (ICRP). It was observed that there are several locations in India where dwellings have higher indoor radon levels than the ICRP recommended value and requires some sort of intervention from regulating authorities. The mean value for indoor radon level given in the report of UNSCEAR 2000 for India needs to be revised.  相似文献   

12.
Environmental radon exposure of residents of domestic premises in the United Kingdom (UK) and elsewhere in Europe is estimated on the basis of the measured radon concentrations in, and the relative occupancies of, the principal living room and bedroom. While studies on radon concentration variability in the individual units in apartment blocks in various countries have been described, little data has been reported on variability in two-storey single-family dwellings, and the majority of extant studies consolidate living room and bedroom data early in the analysis. To investigate this further, detailed analysis was made of radon concentration data from a set of thirty-four homes situated in areas of Northamptonshire known to exhibit high radon levels. All homes were of typical UK construction of brick/block/stone walls under a pitched tile/slate roof. Approximately 50% of the sample were detached houses, the remainder being semi-detached (duplex) or terraced (row-house). Around 25% of the sample possessed cellars, while 12% were single-storey dwellings (bungalows), reflecting the typical incidence of this type of dwelling in England. In the two-storey homes, all monitored bedrooms were on the upper floor. Distribution of the ratios of bedroom/living room radon concentrations (BR/LR ratio) in individual properties was left-skewed (mean 0.67, median 0.73, range 0.05-1.05) with a tail extending to just above 1.0. The mean is consistent with the outcome of earlier extensive studies in England, while the variability depends principally on the characteristics of the property, and not on seasonal factors. In a small set of homes, the BR/LR ratio was anomalously low, (mean 0.3). BR/LR ratios in single-storey homes clustered around a value of 1.0, indicating that house design, rather than lifestyle, is the dominant factor in determining bedroom radon concentrations. Homes with higher mean annual radon concentrations showed lower BR/LR ratios, supporting our proposal that, in some homes, radon emanation from building materials may comprise a significant component of the overall radon level.  相似文献   

13.
Although United Kingdom (UK) Building Regulations applicable to houses constructed since 1992 in Radon Affected Areas address the health issues arising from the presence of radon in domestic properties and specify the installation of radon-mitigation measures during construction, no legislative requirement currently exists for monitoring the effectiveness of such remediation once construction is completed and the houses are occupied. To assess the relative effectiveness of During-Construction radon reduction and Post-Construction remediation, radon concentration data from houses constructed before and after 1992 in Northamptonshire, UK, a designated Radon Affected Area, was analysed. Post-Construction remediation of 73 pre-1992 houses using conventional fan-assisted sump technology proved to be extremely effective, with radon concentrations reduced to the Action Level, or below, in all cases. Of 64 houses constructed since 1992 in a well-defined geographical area, and known to have had radon-barrier membranes installed during construction, 11% exhibited radon concentrations in excess of the Action Level. This compares with the estimated average for all houses in the same area of 17%, suggesting that, in some 60% of the houses surveyed, installation of a membrane has not resulted in reduction of mean annual radon concentrations to below the Action Level. Detailed comparison of the two data sets reveals marked differences in the degree of mitigation achieved by remediation. There is therefore an ongoing need for research to resolve definitively the issue of radon mitigation and to define truly effective anti-radon measures, readily installed in domestic properties at the time of construction. It is therefore recommended that mandatory testing be introduced for all new houses in Radon Affected Areas.  相似文献   

14.
Although radon can be present within buildings at sufficient levels to pose a health risk, levels can be reduced relatively easily. Recent studies on a group of radon-remediated homes, based on assessment of collective population-average risk coefficients, have estimated the benefits and cost effectiveness accruing from remediation and have confirmed that domestic remediation in UK radon Affected Areas would result in significantly reduced cancer risks to the population in those areas. Although the population-average approach used hitherto has applied occupancy and lung-cancer risk factors, these are potentially misleading in assessing discrete populations. The study reported here uses the recently developed European Community Radon Software (ECRS) to quantify individual risks in a sample of householders who remediated their homes following indications that radon levels exceeded the action level. The study proceeds from population-averaged to 'individual risk' evaluation, successfully comparing individual and collective risk assessments, and demonstrates that those who remediate are not representative of the general population. Health benefits accruing from remediation are three times lower than expected, largely because remediators are older, live in smaller households, and smoke less than the population average, leading to the conclusion that the current strategy employed in the UK is failing to target those most at risk.  相似文献   

15.
The results of a survey of outdoor radon concentrations in Milan are reported. Measurements were performed hourly over a continuous four year period from January 1997 to December 2000. Radon concentration was obtained by two means: both direct measurement of radon; and measurement of its decay products. The average daily pattern of radon concentration featured a minimum in the late afternoon and a maximum in the early hours of the morning. A seasonal pattern with higher concentrations in winter than in summer (from around 15 Bq m(-3) in winter to around 5 Bq m(-3) in summer) was also observed. Similar average annual values of around 10 Bq m(-3) were obtained. The annual effective outdoor radon dose was found to be 0.12 mSv. The variation from minimum in the afternoon to maximum the following morning was found to be a good indicator of the height of the nocturnal mixing layer. The variation between maximum and minimum levels on the same day is an index of the maximum height of the mixing layer. Furthermore, our long term measurements of radon have permitted us to examine the dispersion characteristics of the atmosphere over Milan, and to establish the frequency of conditions unfavourable to the dispersion of atmospheric pollutants.  相似文献   

16.
In this study, seasonal observations of radon concentration changes inside buildings carried out in the northeastern region of Poland is presented. One-year measurements of radon concentrations were performed in chosen buildings. The integral method of Cr-39 trace detectors in diffusive chambers was used. Mean values of radon concentrations were determined in monthly, 2-, 3-, 6-month, and annual observations. The fraction of a mean annual concentration of the value obtained in a shorter observation was calculated. Monthly concentration values were from about 0.2 to 14.9 of the annual mean. All buildings revealed seasonal fluctuation of radon concentration. Negative correlation of indoor radon concentration in the buildings and the mean temperature outside was observed in most examined buildings. The lowest coefficient range, determining which part of the annual mean value would be obtained in the 6-month observation, was gained for exposure begun in April or October.  相似文献   

17.
Building regulations in the UK have since 1992 required that radon-proof membranes be installed in new domestic properties to protect residents against the adverse effects of radon. This study compares the cost-effectiveness of the current regulatory regime with an alternative that would entail new properties being tested for radon after construction, and being remediated if necessary. The alternative regime is found to be more cost-effective for a sample of properties in Brixworth, Northamptonshire, UK. For this regime, the central estimate of cost per quality-adjusted life-year gained, the measure of cost-effectiveness used, is 2869 pounds compared to 6182 pounds for installing membranes, results suggesting a case for re-examining the current regulations on radon protection in new properties. Pilot studies will, however, be needed to consider how different means of protecting residents of new properties against radon might operate in practice and to provide improved evidence on their relative cost-effectiveness.  相似文献   

18.
Radon-222 in Brazil: an outline of indoor and outdoor measurements   总被引:3,自引:0,他引:3  
This study discusses the methodology for measuring and assessing the radon concentration in indoor and outdoor environments. A research study was developed to investigate the long-term behavior of the diurnal and seasonal fluctuations of radon (222)Rn EEC (Equilibrium-Equivalent Concentration) and the influence of temperature and other climatic aspects on this behavior. The study was performed by means of both integrated and instantaneous measurements of radon and its short-lived daughter products for a period of 1 year in an indoor environment in Rio de Janeiro city, Brazil (reference environment), with continuous measurement, using a radon monitor with an alpha spectrometry detector.For a single day, a variability of about 50% could be observed in the (222)Rn EEC values measured on a hourly basis, with a maximum occurring early in the morning and a minimum in the afternoon. For the long-term period, seasonality is responsible for a two order of magnitude variability, with a maximum of 50 Bq.m(-3) in winter (dry season) and a minimum of 0.5 Bq.m(-3) in the summer months (wet season), outdoors. A negative correlation with temperature was observed. The conclusions of this experiment led to a survey of radon gas concentration in dwellings in Rio de Janeiro city, Brazil, in urban area with nearly 7 million inhabitants, through integrated sampling methods, using a Solid State Nuclear Track Detectors Technique (SSNTD). The study was conducted in different geomorphological locations in town. The radon gas concentration in Rio de Janeiro dwellings ranged from 5 Bq.m(-3) to 200 Bq.m(-3). A good correlation between indoor radon gas concentration and location of dwellings was observed. The seashore areas presented the lowest levels of indoor radon concentration, whereas the highest levels were found close to the mountains.  相似文献   

19.
LR- 115 plastic track detectors have been used to measure indoor radon level in some dwellings of Una district, Himachal Pradesh, India. The annual average radon concentration in dwellings in most of the villages falls in the range of the action level recommended by the International Commission on Radiological Protection. The radon values in some of the dwellings exceed the action level and may be unsafe from the health hazard point of view. The indoor radon values are in general higher in winter than in summer. Uranium, radium and radon exhalation studies have also been carried out in soil samples collected from these areas. A good correlation is obtained between uranium concentration in the soil and indoor radon in dwellings. The soil radon exhalation rate also correlates with the uranium concentration in soil.  相似文献   

20.
In general, indoor radon concentration is subject to seasonal variability. The reasons are to be found (1) in meteorological influence on the transport properties of soil, e.g. through temperature, frozen soil layers and soil water saturation; and (2) in living habits, e.g. the tendency to open windows in summer and keep them closed in winter, which in general leads to higher accumulation of geogenic Rn in closed rooms in winter. If one wants to standardize indoor Rn measurements originally performed at different times of the year, e.g. in order to make them comparable, some correction transform as a function of measurement time which accounts for these effects must be estimated. In this paper, the seasonality of indoor Rn concentration measured in Austria is investigated as a function of other factors that influence indoor Rn. Indoor radon concentration is clearly shown to have seasonal variability, with higher Rn levels in winter. However, it is complicated to quantify the effect because, as a consequence of the history of an Rn survey, the measurement season maybe correlated to geological regions, which may introduce a bias in the estimate of the seasonality amplitude.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号