首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Our group previously demonstrated that carbon dioxide (CO2) levels in heavily occupied schools correlate with the levels of airborne bacterial markers. Since CO2 is derived from the room occupants, it was hypothesized that in schools, bacterial markers may be primarily increased in indoor air because of the presence of children; directly from skin microflora or indirectly, by stirring up dust from carpets and other sources. The purpose of this project was to test the hypothesis. Muramic acid (Mur) is found in almost all bacteria whereas 3-hydroxy fatty acids (3-OH FAs) are found only in Gram-negative bacteria. Thus Mur and 3-OH FA serve as markers to assess bacterial levels in indoor air (pmol m(-3)). In our previous school studies, airborne dust was collected only from occupied rooms. However, in the present study, additional dust samples were collected from the same rooms each weekend when unoccupied. Samples were also collected from outside air. The levels of dust, Mur and C10:0, C12:0, C14:0, and C16:0 3-OH FAs were each much higher (range 5-50 fold) in occupied rooms than in unoccupied school rooms. Levels in outdoor air were much lower than that of indoor air from occupied classrooms and higher than the levels in the same rooms when unoccupied. The mean CO2 concentrations were around 420 parts per million (ppm) in unoccupied rooms and outside air; and they ranged from 1017 to 1736 ppm in occupied rooms, regularly exceeding 800-1000 ppm, which are the maximum levels indicative of adequate indoor ventilation. This indicates that the children were responsible for the increased levels of bacterial markers. However, the concentration of Mur in dust was also 6 fold higher in occupied rooms (115.5 versus 18.2 pmole mg(-1)). This further suggests that airborne dust present in occupied and unoccupied rooms is quite distinct. In conclusion in unoccupied rooms, the dust was of environmental origin but the children were the primary source in occupied rooms.  相似文献   

2.
Previously it was demonstrated that the levels of large particles (>2 micron) and associated bacterial cell envelope markers increase greatly on occupation in schools; it was hypothesized that the source of both was shed human skin. In the current work to test this hypothesis, room air cleaners were used to collect airborne dust (>50-100 mg) from occupied and unoccupied school rooms which was then subjected to proteomic analysis. Proteins were extracted from the dust and separated using two dimensional gel electrophoresis (2D GE). In situ digestion of protein spots with trypsin released peptides, which were subsequently analyzed by matrix assisted laser desorption/deionization, time-of-flight mass spectrometry (MALDI-TOF-MS) and tandem mass spectrometry (MALDI-TOF-MS-MS). In Coomassie blue stained gels, a single spot generally dominated the 2D gels; this protein was identified by tandem mass spectrometry as K10 epithelial keratin. The results experimentally confirm previous anecdotal reports that human skin is readily shed into air and suggest that increased levels of microbial markers and large particles observed in occupied rooms are also derived from skin.  相似文献   

3.
Gas chromatography-mass spectrometry (GC-MS) using a quadrupole instrument and GC-tandem MS (GC-MS-MS) using an ion trap instrument were applied to determine 3-hydroxy fatty acids (3-OH FAs) with 10-18 carbon chain lengths, specific components of the endotoxin (lipopolysaccharide, LPS) of Gram-negative bacteria, in 30 house dust samples. The two methods provided similar detection sensitivity for methyl ester/trimethylsilyl derivatives of the 3-OH FAs and allowed these acids to be distinguished from co-eluting 2-OH FA derivatives. The correlation coefficients between endotoxin activity (Limulus test) and the combined amounts of 3-OH C10, 3-OH C12, and 3-OH C14 were 0.60 and 0.61 when using GC-MS and GC-MS-MS, respectively. The superior selectivity of GC-MS-MS was illustrated in analyses of sub-milligram amounts of dust, where the chromatograms achieved by GC-MS were difficult to interpret due to a high background and several closely eluting compounds. GC-MS-MS is therefore preferable to GC-MS for determining 3-OH FAs in minute (sub-milligram) amounts of dust.  相似文献   

4.
A GC-MS method for the quantification of bacterial lipopolysaccharides (LPS, endotoxin) is presented. After hydrolytic cleavage of 3-hydroxy fatty acids (3-OH FAs) from the lipid A region of LPS, derivatisation of both the hydroxyl and the carboxyl group was performed in one step with a mixture of methyl-bis(trifluoracetamide)(MBTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoracetamide (MTBSTFA). Using GC-MS in the EI mode with selected ion monitoring (SIM) for analysis, baseline separation of 3-OH FAs (and of possibly interfering 2-OH FAs) was achieved. The sensitivity of the method (LOD 7-50 pg/injection for the different 3-OH FAs investigated) allows for the efficient quantification of LPS in occupational and environmental samples. Degradation of 3-OH FAs as well as of their derivatives during sample preparation and GC-MS separation as a possible source of errors in analytical methods based on 3-OH FA determination is reported for the first time. Thermal elimination of water from the underivatised 3-OH FAs and of trifluoroacetic acid from the derivatives was identified as the cause of degradation. The resulting alpha,beta-unsaturated compounds showing the same mass spectra as the 3-OH FA derivatives were detected as more or less prominent satellite peaks. By using alkaline instead of acidic hydrolysis and cool on-column instead of split/splitless injection, elimination was reduced to an acceptable level.  相似文献   

5.
Elevated concentrations of endotoxin in indoor air due to cigarette smoking   总被引:1,自引:0,他引:1  
Exposure to environmental tobacco smoke (ETS) is an important worldwide public health issue. The present study demonstrates that cigarette smoke can be a major source of endotoxin (lipopolysaccharide, LPS) in indoor environments. Gas-chromatography/mass-spectrometry was used to determine 3-hydroxy fatty acids as markers of endotoxin in air-borne house dust in homes of smokers and non-smokers. Air concentrations of endotoxin were 4-63 times higher in rooms of smoking students than in identical rooms of non-smoking students. The fact that cigarette smoke contains large amounts of endotoxin may partly explain the high prevalence of respiratory disorders among smokers and may also draw attention to a hitherto neglected risk factor of ETS.  相似文献   

6.
Muramic acid (MA) is a unique amino sugar that is a constituent of the peptidoglycan (PG) present in prokaryotic cell walls. MA can serve as a marker for quantifying bacterial load, e.g. in indoor environments, by using gas chromatography-tandem mass spectrometry (GC-MS-MS). We demonstrated recently that the methyl ester O-methyl acetate (MMA) derivative can be used to detect MA in house dust by ion-trap GC-MS-MS. However, since the MMA derivative is not formed from free MA quantification was not optimal. Here we report 1) significant improvements in sample preparation of the MMA derivative and 2) an evaluation of the performance of derivative, using for comparison the alditol acetate derivative, the gold standard in quantitative trace analysis of MA in complex matrices. The MMA derivative was analysed using an MS instrument with internal ionization and the alditol acetate derivative was analysed using an instrument with external ionization. 13C-labelled cyanobacteria, containing MA in their PG, were used as the internal standard. A linear relationship was found between the two methods in studies on 27 parallel samples of airborne dust from school classes collected on filters. Although the analytical sensitivity of the MMA derivatives was somewhat slightly lower than of the alditol acetate derivative, this may be due to differences in yield of derivative, sample clean-up efficiency, or different performance of the GC columns or MS instruments. However preparation of the MMA derivative is quick and compatible with preparation of methyl esters of 3-hydroxy fatty acids (used as markers of Gram negative endotoxin) allowing the levels of both markers to be determined in the same dust sample. In conclusion, the MMA procedure can be used to determine MA in environmental samples with good reproducibility provided the concentration of the 13C-labelled MA internal standard in the cyanobacteria is first determined with an alternative method.  相似文献   

7.
近年来,空气污染已成为长三角地区最关键的环境问题之一,气溶胶颗粒物(PM)是最主要的污染物之一.生物气溶胶作为颗粒物的重要组成部分,可能对空气质量和人体健康产生不利影响.利用高通量测序方法研究了江苏省泰州2019年11月至2020年1月期间发生沙尘和霾污染时生物气溶胶中细菌群落结构组成特征.结果表明:冬季沙尘天和霾天气...  相似文献   

8.
Endotoxin exposure is associated with wheeze and asthma morbidity, while early life exposure may reduce risk of allergy and asthma. Unfortunately, it is difficult to compare endotoxin results from different laboratories and environments. We undertook this study to determine if lipopolysaccharide (LPS) extraction efficiency could account for differences among laboratories. We generated and collected aerosols from chicken and swine barns, and corn processing. We randomly allocated side-by-side filter samples to five laboratories for Limulus assay of endotoxin. Lyophilized aliquots of filter extracts were analyzed for 3-hydroxy fatty acids (3-OHFAs) as a marker of LPS using gas chromatography-mass spectrometry. There were significant differences in endotoxin assay and GC-MS (LPS) results between laboratories for all dust types (p < 0.01). Patterns of differences between labs varied by dust type. Relationships between assay and GC/MS results also depended on dust type. The percentages of individual 3-OHFA chain lengths varied across labs (p < 0.0001) suggesting that each lab recovered a different fraction of the LPS available. The presence of large amounts of particle associated LPS and absence of a freezing thawing cycle were associated with lower correlations between LPS and bioactivity, consistent with an absence of Limulus response to cell-bound endotoxin. These data suggest that extraction methods affect endotoxin measurements. The LAL methods may be most suitable when comparing exposures within similar environments; GC-MS offers additional information helpful in optimizing sample treatment and extraction. GC-MS may be of use when comparing across heterogeneous environments and should be considered for inclusion in future studies of human health outcomes.  相似文献   

9.
The use of hydrated magnesium carbonate hydroxide (magnesia alba) for drying the hands is a strong source for particulate matter in indoor climbing halls. Particle mass concentrations (PM10, PM2.5 and PM1) were measured with an optical particle counter in 9 indoor climbing halls and in 5 sports halls. Mean values for PM10 in indoor climbing halls are generally on the order of 200-500 microg m(-3). For periods of high activity, which last for several hours, PM10 values between 1000 and 4000 microg m(-3) were observed. PM(2.5) is on the order of 30-100 microg m(-3) and reaches values up to 500 microg m(-3), if many users are present. In sports halls, the mass concentrations are usually much lower (PM10 < 100 microg m(-3), PM2.5 < or = 20 microg m(-3)). However, for apparatus gymnastics (a sport in which magnesia alba is also used) similar dust concentrations as for indoor climbing were observed. The size distribution and the total particle number concentration (3.7 nm-10 microm electrical mobility diameter) were determined in one climbing hall by an electrical aerosol spectrometer. The highest number concentrations were between 8000 and 12 000 cm(-3), indicating that the use of magnesia alba is no strong source for ultrafine particles. Scanning electron microscopy and energy-dispersive X-ray microanalysis revealed that virtually all particles are hydrated magnesium carbonate hydroxide. In-situ experiments in an environmental scanning electron microscope showed that the particles do not dissolve at relative humidities up to 100%. Thus, it is concluded that solid particles of magnesia alba are airborne and have the potential to deposit in the human respiratory tract. The particle mass concentrations in indoor climbing halls are much higher than those reported for schools and reach, in many cases, levels which are observed for industrial occupations. The observed dust concentrations are below the current occupational exposure limits in Germany of 3 and 10 mg m(-3) for respirable and inhalable dust. However, the dust concentrations exceed the German guide lines for work places without use of hazardous substances. In addition, minimizing dust concentrations to technologically feasible values is required by the current German legislation. Therefore, substantial reduction of the dust concentration is required.  相似文献   

10.
采用单颗粒气溶胶飞行时间质谱仪(Single Particle Aerosol Mass Spectrometer,SPAMS)对西安市大气矿尘颗粒物进行连续12 d在线分析,共采集到107 425个同时含有正负质谱信息的矿尘颗粒,矿尘颗粒物占PM_(2.5)样本数的8.44%。结果表明,矿尘颗粒物的正离子碎片成分以Na~+、K~+、Al~+、Ca~+、CaO~+、Fe~+为主,同时还含有Pb~+等,负离子碎片成分以NO~-_2和NO~-_3为主,另外还含有HSO~-_4、SiO~-_3、HSiO~-_3、H(NO_3)~-_2等。在西安市大气细颗粒物中,矿尘颗粒物中贡献较大的几类(如含钙、含铁、铁氧颗粒物等)大多是老化的成分。将观测阶段采集到的矿尘颗粒纳入本地污染源谱进行来源分析,其主要来源为扬尘源、工业源、燃煤源和汽车尾气源等。  相似文献   

11.
Epidemiological research has demonstrated the relationship between exposure to quartz dust and an elevated risk of pneumoconiosis and possible elevated risk of cancer. The current study was designed to evaluate the biological responses of workplace particles containing crystalline silica using an in vitro cell test. Respirable particle samples were sampled from four tin mines, where the standardized mortality ratio (SMR) for pneumoconiosis was 51.6 and SMR for lung cancer was 2.2 in dust-exposed miners. Alveolar macrophages (AM) are considered as the target cells for primary dust effects. The samples were then measured at 15, 30, 60 and 120 microg particle per 10(6) AM for cytoxicity with the release of glucuronidase, lactate dehydrogenase, for reactive oxygen damage with H(2)O(2) release, and for ability to induce fibrosis using the secretion of tumor necrosis factor-alpha (TNF-alpha). Pure quartz (DQ12) and corundum were used as controls. The results showed the samples from tin mines caused a higher cytoxicity when compared to corundum, yet lower when compared to quartz. However, reactive oxygen species release (148-177 nmol/3 x 10(5) AM in high concentration of 120 microg/10(6) AM) induced by the samples were significantly higher than that induced by quartz (57 nmol/3 x 10(5) AM) and corundum (62 nmol/3 x 10(5) AM). Furthermore, particle samples induced higher TNF-alpha secretion than corundum, the samples from Limu tin mine induced much higher TNF-alpha levels than that induced by DQ12 quartz. The results from the in vitro tests help elucidate the degree of hazard of dust particles in tin mines. The in vitro reaction patterns of AM also constitute a powerful tool to monitor biological and pathogenic responses of humans following dust particle exposure.  相似文献   

12.
Methodology for identifying particle sources in indoor environments   总被引:1,自引:0,他引:1  
Growing concern about airborne particles in indoor environments requires fast source identification in order to apply remedial actions. A methodology for identifying sources emitting particles larger than 0.5 microm was designed and applied. It includes: (1) visual inspection of interior surfaces in order to identify deposited particles and inspection of potential sources (equipment, materials, activities etc.) of airborne particles. (2) Technical measurements of airborne particles at different positions in a building with simultaneous logging of activities. (3) Isolating potential activities/particle sources in a test chamber, initially free from particles, for controlled characterizations of the particles generated. The methodology was applied in a study of three houses in southern Sweden. The results show that source identification is facilitated by knowledge of concentration variations between different rooms, real-time measurements together with activity reports and information on particle characteristics that are comparable with results from laboratory simulations. In the houses to which the methodology was applied, major particle emissions from textile handling were identified, which were likely due to detergent zeolite residues.  相似文献   

13.
The aim of this study was to estimate mite antigen exposure in farming environments by passive sampling of airborne dust. Antigen concentrations were measured with enzyme immunoassays specific for three storage mites (SM): Acarus siro, Lepidoglyphus destructor, Tyrophagus putrescentiae and the house dust mite (HDM) Dermatophagoides pteronyssinus. Dust samples were collected with electrostatic dust fall collectors (EDCs) in three different areas of cattle farms. EDCs were placed in cow stables (working area), in changing rooms (transit area) and in different rooms of farmer dwellings (living area). Mite concentrations in the living area of farm homes were compared to those of urban homes. In dust samples from stables, antigens of all four mite species could be detected. The highest exposure level was to L. destructor (median 56.7 μg/m(2)), the lowest to A. siro (median 14.4 μg/m(2)). Mite concentrations of different species showed no correlation within the cow stables. In comparison to stables, the median mite concentrations in farm homes were significantly lower, ranging from below the detection limit to 1.5 μg/m(2). Antigens of SM were predominantly found in changing rooms and kitchens, and HDM antigens were mainly detected in bedrooms. Antigens of all mites were measured the least often in living rooms. T. putrescentiae was the most prevalent mite in all room types, and the exposure levels correlated strongly between different rooms. The number of SM positive samples in farm homes was considerably higher than in urban homes, while the percentage of HDM positive samples did not differ significantly.  相似文献   

14.
In order to be able to make a decision, as to whether a room or building has a health-endangering pentachlorophenol (PCP) concentration, usually the PCP concentrations in air and settled dust are measured. The variability of the PCP concentration in indoor air and dust was studied. Air and dust samples were taken from 75 rooms in 30 buildings with suspicion of application of PCP-containing wood preservatives. Sampling was repeated four times within 18 months. Thirty-six rooms were reconstructed within the study; 39 rooms had unchanged contamination status during the study. The four times repeated measurements of PCP concentrations in air and dust in these rooms showed large variations of the measured values. The variability of the results is to a large extent in the same range as the measured values. The observed relative standard deviation of the PCP concentrations in air and dust does not depend on the average PCP concentration detected in the individual rooms.  相似文献   

15.
Measurements of aerosols were made in 2001 and 2002 at Dunhuang (40 degrees 00'N, 94 degrees 30'E), China to understand the nature of atmospheric particles over the desert areas in the Asian continent. Balloon-borne measurements with an optical particle counter suggested that particle size and concentration had noticeable peaks in super micron size range not only in the boundary mixing layer but also in the free troposphere. Super-micron particle concentration largely decreased in the mid tropopause (from 5 to 10 km; above sea level, a.s.l.). Lidar measurements made during August 2002 at Dunhuang suggested the possibility that mixing of dust particles occurred from near the ground to about 6 km even under calm weather conditions, and a large depolarization ratio of particulate matter was found in the aerosol layer. The top of the aerosol layer was found at heights of nearly 6 km (a.s.l.). It is strongly suggested that nonspherical dust particles (Kosa particles) frequently diffused in the free atmosphere over the Taklamakan desert through small-scale turbulences and are possible sources of dust particles of weak Kosa events that have been identified in the free troposphere not only in spring but also in summer over Japanese archipelago. Electron microscopic experiments of the particles collected in the free troposphere confirmed that coarse and nonspherical particles observed by the mineral particle were major components of coarse mode (diameter larger than 1 microm) below about 5 km over Dunhuang, China.  相似文献   

16.
Measurement of environmental endotoxin exposures is complicated by variability encountered using current biological assay methods arising in part from lot-to-lot variability of the Limulus-amebocyte lysate (LAL) reagents. Therefore, we investigated the lot-to-lot repeatability of commercially available recombinant Factor C (rFC) kits as an alternative to LAL. Specifically, we compared endotoxin estimates obtained from rFC assay of twenty indoor dust samples, using four different extraction and assay media, to endotoxin estimates previously obtained by Limulus amebocyte lysate (LAL) assay and amounts of 3-hydroxy fatty acids (3-OHFA) in lipopolysaccharide (LPS) using gas-chromatography mass spectroscopy (GC-MS). We found that lot-to-lot variability of the rFC assay kits does not significantly alter endotoxin estimates in house dust samples when performed using three of the four assay media tested and that choice of assay media significantly altered endotoxin estimates obtained by rFC assay of house dust samples. Our findings demonstrate lot-to-lot reproducibility of rFC assay of environmental samples and suggest that use of rFC assay performed with Tris buffer or water as the extraction and assay medium for measurement of endotoxin in dust samples may be a suitable choice for developing a standardized methodology.  相似文献   

17.
To investigate the diurnal profile of the concentration and composition of ambient coarse particles, three sampling sites were set up in the Los Angeles Basin to collect coarse particulate matter (CPM) in four different time periods of the day (morning, midday, afternoon and overnight) in summer and winter. The samples were analyzed for total and water-soluble elements, inorganic ions and water-soluble organic carbon (WSOC). In summer, highest concentrations of CPM gravimetric mass, mineral and road dust, and WSOC were observed in midday and afternoon, when the prevailing onshore wind was stronger. In general, atmospheric dilution was lower in winter, contributing to the accumulation of air pollutants during stagnation conditions. Turbulences induced by traffic become a significant particle re-suspension mechanism, particularly during winter night time, when mixing height was lowest. This is evident by the high levels of CPM mass, mineral and road dust in winter overnight at the near-freeway sites located in urban Los Angeles, and to a lesser extent in Riverside. WSOC levels were higher in summer, with a similar diurnal profile with mineral and road dust, indicating that they either share common sources, or that WSOC may be adsorbed or absorbed onto the surfaces of these dust particles. In general, the contribution of inorganic ions to CPM mass was greater in the overnight sampling period at all sampling sites, suggesting that the prevailing meteorological conditions (lower temperature and higher relative humidity) favor the formation of these ions in the coarse mode. Nitrate, the most abundant CPM-bound inorganic species in this basin, is found to be predominantly formed by reactions with sea salt particles in summer. When the sea salt concentrations were low, the reaction with mineral dust particles and the condensation of ammonium nitrate on CPM surfaces also contributes to the formation of nitrate in the coarse mode.  相似文献   

18.
Springtime urban road dust forms one of the most serious problems regarding air pollution in Finland. The composition and origin of springtime dust was studied in southern Finland with two different methods. Suspended particles (PM10 and TSP) were collected with high volume particle samplers and particle deposition was collected with moss bags. The composition of the PM(1.5-10) fraction was studied using individual particle analysis with SEM/EDX. The deposition in the moss bags was analysed with ICP-MS. The results showed that during the study period, approximately 10% of both PM(1.5-10) particles and the deposition originated from sanding. Other sources in the springtime PM(1.5-10) were e.g. asphalt aggregate or soil and combustion processes. It can be concluded that sanding produced a relatively small amount of particulate matter under the investigated circumstances.  相似文献   

19.
About 60,000 particles in 288 aerosol samples collected during farm work have been characterised with automated particle analysis using scanning electron microscopy (SEM) and energy dispersive X-ray spectrometry (EDS). Based on EDS-analysis of materials with known composition (potato flour, alpha-quartz, K-feldspar and beta-wollastonite), criteria were developed for classification of particles as: (1) organic, (2) silicon-rich (silica), and (3) other inorganic particles. The reproducibility of the relative mass proportions in dust samples collected during farm work was 0.078 when approximately 200 particles were characterised per sample. Field samples from the farm environment showed clear differences in composition. Generally, inorganic particles dominated the particle mass. The proportion of the organic particle mass was highest for tending of swine and poultry, 55 and 38% respectively. Silica particles amounted to 10 to 20% of the total mass during handling crops, e.g. grain, straw, hay, potatoes, and onions. It seems likely that the results can be used in etiologic studies, but further validation would be needed for quantitative purposes.  相似文献   

20.
Soil dust particles transported from loess regions of the Asian continent, called Asian dust, highly influences the air quality of north-eastern Asia and the northern Pacific Ocean. In order to investigate the effects of these dust storms on the chemical composition of atmospheric aerosol particles with different size, measurements of size distributions of total aerosol and major ion species were carried out on Jeju Island, Korea during April 2001. Juju Island was chosen for the study because the levels of emissions of anthropogenic air pollutants are very low. A 5-stage cascade impactor was used to sample size-fractionated aerosol particles. Samples were analyzed for major water-soluble ions using Dionex DX-120 ion chromatograph. The average mass concentration of total aerosol was found to be 24.4 and 108.3 microg m(-3) for non-Asian dust and Asian dust periods, respectively. The total aerosol size distribution, measured during the non-Asian dust period, was bimodal, whereas the coarse particles dominated the size distribution of total aerosol during the Asian dust period. It was found that SO4(2-), NH4+ and K+ were mainly distributed in fine particles, while Cl-, NO3-, Na+, Mg2+ and Ca2+ were in coarse particles. Although SO4(2-) was mainly distributed in fine particles, during the Asian dust period, the concentrations in coarse particles were significantly increased. This indicates heterogeneous oxidation of SO2 on wet surfaces of basic soil dust particles. The NH4+ was found to exist as (NH4)2SO4 in fine particles, with a molar ratio of NH4+ to SO4(2-) of 2.37 and 1.52 for non-Asian dust and Asian dust periods, respectively. Taking into account the proximity of the sampling site to the sea, and the observed chloride depletion, coarse mode nitrate, during the non-Asian dust period, is assumed to originate from the reaction of nitric acid with sodium chloride on the surfaces of sea-salt particles although the chloride depletion was not shown to be large enough to prove this assumption. During the Asian dust period, however, chloride depletion was much smaller, indicating coarse nitrate particles were mainly produced by the reaction of nitric acid with surfaces of basic soil particles. Most chloride and sodium components were shown to originate from sea-salt particles. Asian dust aerosols, arriving at Jeju Island, contained considerable amounts of sea-salt particles as they passed over the Yellow Sea. Ca2+ was shown to be the most abundant species in Asian dust particles.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号