共查询到20条相似文献,搜索用时 0 毫秒
1.
2.
为了解北京市公共场所室内甲醛污染水平及影响因素,在工作日和周末上下午对北京市内家具市场、综合商场和服装批发市场3类公共场所不同功能区的室内甲醛浓度进行监测和分析。结果表明:家具市场中包含木质家具的功能区甲醛浓度最高;服装批发市场中包含外贸针织功能区的甲醛浓度最高;综合商场中包含化妆品功能区的甲醛浓度最高;服装批发市场和家具市场整体的甲醛浓度已超过《商场(店)、书店卫生标准》(GB 9670—1996)规定的限值0.12mg/m3。3类公共场所甲醛点位超标率服从显著性水平p0.05的χ2双侧检验,具有统计学意义。长期暴露在服装批发市场和家具市场内的工作人员和顾客,可能存在健康风险,应对家具市场、服装批发市场的甲醛污染进行控制。 相似文献
3.
Wanyang Liu Satoshi Takahashi Yui Sakuramachi Kouji H. Harada Akio Koizumi 《Chemosphere》2013,90(5):1672-1677
The fluorotelomer alcohols (FTOHs) have been detected in various environmental compartments, including indoor and outdoor air, in North America and Europe. In our previous studies, FTOHs were detected at a relative higher concentration in outdoor air in the Keihan (Kyoto–Osaka, one of the major industrial zones) area, Japan compared to reported data. The exposure level of FTOHs in indoor air in the Keihan area remains unclear. In the present study, indoor air FTOH concentrations were investigated using a passive air sampler containing activated carbon felts. The indoor air sampling was conducted in 49 households of the Keihan area, during winter and summer 2008. Most samples contained 6:2 FTOH, 8:2 FTOH, 10:2 FTOH and 8:2 FTOAc. The median concentration of 8:2 FTOH (5.84 ng m?3) was highest among fluorotelomers, followed by those of 10:2 FTOH (1.12 ng m?3), 6:2 FTOH (0.29 ng m?3), and others. Significant correlations among fluorotelomers were observed in collected samples. The association between housing conditions and 8:2 FTOH concentrations showed that samples collected from bed rooms have higher 8:2 FTOH concentrations than those collected from other locations. In addition, samples collected in winter showed lower levels of 8:2 FTOH than those collected in summer. These findings suggest that 8:2 FTOH is the predominant component among fluorotelomers in indoor air, and that there are emission sources of fluorotelomers in indoor environments of the Keihan area. Further investigations into the origins of fluorotelomers are needed to evaluate indoor contamination with fluorotelomers. 相似文献
4.
室内甲醛污染治理实验研究 总被引:1,自引:1,他引:1
针对装修所带来的室内甲醛污染危害,采用活性炭、甲醛清除剂来去除室内甲醛,并对其去除效果、影响因素进行了研究。结果表明,在活性炭、甲醛清除剂最佳使用量下,甲醛清除剂的去除率显著高于活性炭去除率,且持久性较好;最佳量的甲醛清除剂在治理不同板材所含的甲醛时,中密度板的甲醛去除率均高于木板、细木工板和装饰单面贴面胶合板的去除率;环境温度升高时,甲醛清除剂其去除效率有所降低。甲醛清除剂对室内甲醛有明显的去除。 相似文献
5.
利用PCO技术,针对现有的室内挥发性有机污染物,设计一种能与建筑空调系统的通风换气设备相结合的折流式管状反应器,以甲醛为目标污染物,对其净化效果进行实验分析。结果表明:折流式管状反应器对于甲醛的降解处理效果高于传统的管状反应器,其转化率及矿化率均大于传统管状反应器;相较于波长较长的黑光灯,波长为254 nm的杀菌灯利用率更高,实验效果优于黑光灯;不同初始浓度下甲醛的反应有效度η基本不受催化层厚度影响;以波长254 nm的杀菌灯为紫外光源时,由于光强衰减快,使得催化层厚度对传质速率无明显作用;以波长为365 nm的黑光灯为紫外灯源时,甲醛η值随催化层厚度增加而增大,故在此实验条件下的光催化反应中,紫外光吸收量、反应速率以及反应有效度均会随催化剂负载量增加而增大。 相似文献
6.
7.
Sung Ho Hwang Gil Bong Lee Im Soon Kim 《Journal of the Air & Waste Management Association (1995)》2017,67(3):306-312
The aim of this study was to measure the air concentrations of carbon dioxide (CO2) and formaldehyde (HCHO) in daycare centers to determine relevant influencing factors, including temperature, relative humidity (RH), type of facility, number of children, type of ventilation system, ventilation time, and air cleaning system. The authors measured HCHO, CO2, temperature, and RH in the center of classrooms in 289 daycare centers. Spearman’s correlation and Mann–Whitney analyses were used to examine the relationships and differences in HCHO and CO2 for varying temperatures, RH values, and categorical indoor environmental factors. There were no significant differences in the HCHO and CO2 air concentrations with varying numbers of children, ventilation times, or ventilation and air cleaning system types. However, both the HCHO and CO2 air concentrations were significantly different for varying RH values, which were divided into five categories (p < 0.001). Only the HCHO air concentrations were significantly different for varying temperatures, which were divided into five categories (p < 0.001). Significant correlations were found between HCHO air concentrations and the temperature (r = 0.35, p < 0.0001), RH (r = 0.51, p < 0.0001), and CO2 (r = 0.36, p < 0.0001). The study results support maintaining an appropriate temperature and RH range for reducing airborne HCHO in daycare centers. Further research is needed to elucidate the precise mechanisms responsible for the relationships observed in this study.
Implications: Data from 289 daycare centers in Seoul, South Korea, indicate that HCHO concentrations show a positive correlation with indoor temperature and relative humidity. This indicates that keeping temperatures low will help keep HCHO concentrations low, by both a direct and an indirect effect, since low temperatures also cause low relative humidity. 相似文献
8.
不同植物和吸附剂对室内甲醛的去除效果 总被引:1,自引:0,他引:1
以绿萝、芦荟、活性炭和茶渣为材料,采用密闭箱法进行甲醛净化能力的研究。结果表明,4种物质对甲醛都具有一定的去除效果,但是作用效果差异明显。植物中绿萝对甲醛的净化效果比芦荟好,对不同初始质量浓度甲醛的去除率分别为76.5%、51.8%和40.0%,光照条件有利于植物对甲醛的吸收,甲醛的去除效率提高约39.3%。茶渣表面突起结构和较大的孔隙结构有利于甲醛的去除,对不同初始质量浓度甲醛的去除率分别为49.0%、32.6%和21.1%。动力学研究表明,在所研究的条件范围内,两种吸附剂吸附甲醛符合拟一级动力学,活性炭吸附甲醛的反应速率常数ka=0.0318 min-1,茶渣吸附甲醛的反应速率常数kt=0.0319 min-1。 相似文献
9.
10.
Hajiloo Fakhreddin Hamzeh Saeid Gheysari Mahsa 《Environmental science and pollution research international》2019,26(24):24331-24345
Environmental Science and Pollution Research - The PM2.5 as one of the main pollutants in Tehran city has a devastating effect on human health. Knowing the key parameters associated with PM2.5... 相似文献
11.
利用脉冲放电等离子体-催化耦合技术,进行模拟室内空气循环降解甲醛的实验,对比了3种净化方式(紫外光催化、等离子体单独作用与等离子体-催化耦合)的甲醛降解效果,并考察了中心电极的极性、催化剂活性炭板与中心电极的距离对甲醛降解效果的影响.结果表明,相对单独的紫外光催化和等离子体作用而言,等离子体-催化耦合多重功效结合的甲醛降解效果更好,降解速率也更快;中心电极为正极的电场的甲醛降解效果优于中心电极为负极的电场;随着催化剂活性炭板与中心电极距离的不断扩大,直至板移动至电场外部的过程中,甲醛的降解率表现为先上升后下降的趋势,催化剂活性炭板与中心电极的距离存在一个最佳值,本研究的最佳距离为15mm. 相似文献
12.
《Atmospheric environment (Oxford, England : 1994)》2001,35(11):2001-2007
We have developed a board-like air-cleaning material consisting of activated carbon particles and manganese oxides, by which HCHO gas is decomposed into carbon dioxide even at room temperature. In this study, we investigated removal efficiencies of the air-cleaning board in a passive mode using a kinetic approach. First-order removal rate constant, k, corresponding to air change rate was characterized for the board as a function of the ratio of applied board area to space volume, S/V, and was found directly proportional to S/V with a slope of 25 at 25°C. The performance of the board was evaluated in a full-size laboratory with a constant gas generation. The board suppressed the increase of indoor HCHO concentration and the time course fitted to a theoretical curve. Then, field tests of the air-cleaning board were conducted in newly constructed multi-family houses in Japan from May 1998 to January 1999. The board not only reduced indoor HCHO concentration from 0.21 to 0.04 ppm for more than 7 months, but also enhanced the loss of HCHO gas from building materials in apartments. 相似文献
13.
利用微型实验舱(0.04 m3)模拟室内甲醛环境进行活性炭吸附实验,研究吸附后甲醛浓度随时间的变化趋势,计算活性炭对甲醛的净化效率、吸附速率和饱和吸附量,探索活性炭对室内甲醛的吸附规律.研究发现,当甲醛含量为0 ~0.40 mg,活性炭用量为0.5g时,舱内甲醛浓度随时间延长呈指数递减变化趋势,吸附后0~0.5 h甲醛浓度递减得最快,0.5~2h递减速度变缓,2~4h甲醛浓度基本上保持不变;研究E0A1、E1A4曲线斜率K及活性炭甲醛净化效率发现,每次吸附过程活性炭吸附2h可达到吸附平衡,活性炭进行3次吸附平衡即可达到吸附饱和,每次实验第一次吸附过程、每次吸附过程前半小时活性炭对甲醛的吸附能力最强;活性炭的吸附速率在吸附初期迅速降低,最后趋近于0;等量椰壳活性炭在一定浓度的污染物环境中饱和吸附量是个定值.说明使用活性炭净化室内甲醛有一定的规律可循. 相似文献
14.
Ott WR Klepeis NE Switzer P 《Journal of the Air & Waste Management Association (1995)》2003,53(8):918-936
This paper derives the analytical solutions to multi-compartment indoor air quality models for predicting indoor air pollutant concentrations in the home and evaluates the solutions using experimental measurements in the rooms of a single-story residence. The model uses Laplace transform methods to solve the mass balance equations for two interconnected compartments, obtaining analytical solutions that can be applied without a computer. Environmental tobacco smoke (ETS) sources such as the cigarette typically emit pollutants for relatively short times (7-11 min) and are represented mathematically by a "rectangular" source emission time function, or approximated by a short-duration source called an "impulse" time function. Other time-varying indoor sources also can be represented by Laplace transforms. The two-compartment model is more complicated than the single-compartment model and has more parameters, including the cigarette or combustion source emission rate as a function of time, room volumes, compartmental air change rates, and interzonal air flow factors expressed as dimensionless ratios. This paper provides analytical solutions for the impulse, step (Heaviside), and rectangular source emission time functions. It evaluates the indoor model in an unoccupied two-bedroom home using cigars and cigarettes as sources with continuous measurements of carbon monoxide (CO), respirable suspended particles (RSP), and particulate polycyclic aromatic hydrocarbons (PPAH). Fine particle mass concentrations (RSP or PM3.5) are measured using real-time monitors. In our experiments, simultaneous measurements of concentrations at three heights in a bedroom confirm an important assumption of the model-spatial uniformity of mixing. The parameter values of the two-compartment model were obtained using a "grid search" optimization method, and the predicted solutions agreed well with the measured concentration time series in the rooms of the home. The door and window positions in each room had considerable effect on the pollutant concentrations observed in the home. Because of the small volumes and low air change rates of most homes, indoor pollutant concentrations from smoking activity in a home can be very high and can persist at measurable levels indoors for many hours. 相似文献
15.
电凝并式空气净化单元对颗粒物和甲醛净化效果的实验 总被引:2,自引:0,他引:2
研究一种新型电凝并式空气净化单元对室内空气中颗粒物和甲醛的净化效果.实验结果表明,高压高频(HV-HF)电凝并装置能促使小粒子相互凝并为较大的电中性的粒子团,这些具有较高比表面积的电中性粒子团进入室内空间,能继续粘附空气中及物体表面上的颗粒,形成更大的粒子团,从而易于被净化单元中的中效过滤器捕集,而且该净化单元对于大粒子(粒径>0.7μm)浓度较高的场所净化效果更加明显.另外,室内空气中吸附在颗粒物表面的甲醛也随之被高效去除.该净化单元的投入使用,起到了提高过滤效率、去除气溶胶小粒子、降低能耗、进一步改善室内空气品质等多重功效. 相似文献
16.
Seung-Ho Shin Wan-Kuen Jo 《Environmental science and pollution research international》2013,20(6):3696-3707
This study examined the indoor concentrations of a wide range of volatile organic compounds (VOCs) in currently built new apartments every month over a 24-month period and the source characteristics of indoor VOCs. The indoor total VOC (TVOC) concentrations exhibited a decreasing tendency over the 24-month follow-up period. Similar to TVOCs, the median indoor concentrations of 33 of 40 individual VOCs (all except for naphthalene and six halogenated VOCs) revealed decreasing tendencies. In contrast, the indoor concentrations of the six halogenated VOCs did not reveal any definite trend with time. Moreover, the indoor concentrations of those halogenated VOCs were similar to the outdoor concentrations, suggesting the absence of any notable indoor sources of halogenated VOCs. For naphthalene (NT), the indoor concentrations were significantly higher than the outdoor concentrations, suggesting the presence of indoor NT source(s). The floor/wall coverings (39 %) were the most influential indoor source of indoor VOCs, followed by household cleaning products (32 %), wood paneling/furniture (17 %), paints (7 %), and moth repellents (5 %). 相似文献
17.
M. Žitnik A. Kastelic Z. Rupnik P. Pelicon P. Vaupetič K. Bučar S. Novak Z. Samardžija S. Matsuyama G. Catella K. Ishii 《Atmospheric environment (Oxford, England : 1994)》2010,44(38):4954-4963
We have measured the elemental concentrations in aerosols with a 2-h time resolution in two different types of working environment: a chemistry laboratory dealing with the processing of advanced nanoparticulate materials and a medium-sized machine workshop. Non-stop 10-day and 12-day samplings were performed at each location in order to determine the concentration trends during the non-working/working and weekday/weekend periods. Supplementary measurements of PM10 aerosols with a 2-day sample collection time were performed with a standard Gent PM10 sampler to compare the elemental concentrations with the time-averaged concentrations detected by the 2D step-sampler. The concentrations were determined a posteriori by analyzing the x-ray spectra of aerosol samples emitted after 3-MeV proton bombardment. The PM10 samples collected in the chemistry laboratory were additionally inspected by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) to determine the chemical compositions of the individual particles. In the workshop, a total PM10 mass sampling was performed simultaneously with a minute resolution to compare the signal with typical outdoor PM10 concentration levels. A factor analysis of the time-resolved dataset points to six and eight factors in the chemistry laboratory and the machine workshop, respectively. These factors describe most of the data variance, and their composition in terms of different elements can be related to specific indoor activities and conditions. We were able to demonstrate that the elemental concentration sampling with hourly resolution is an excellent tool for studying the indoor air pollution. While sampling the total PM10 mass concentration with a minute resolution may lack the potential to identify the emission sources in a “noisy” environment, the time averaging on a day time scale is too coarse to cope with the working dynamics, even if elemental sensitivity is an option. 相似文献
18.
利用海藻酸钠及羧甲基纤维素包埋沼泽红假单胞菌海绵作为吸附剂,对甲醛进行吸收处理,其动力学行为与多孔材料相似。用这种海绵组装悬浮式生物反应器,考察其去除室内甲醛污染的性能,结果表明,海绵体积和进风量是影响反应器甲醛净化效率的关键因素。装入6 L海绵和6 L水的反应器在进风量最大(7.8 m3·min-1)时,对室内空气污染浓度为2.0 mg·m-3甲醛的净化效率约为80%。分析水箱水溶液甲醛浓度的变化,结果表明含有甲醛的空气吹入反应器后溶解于水,然后被包埋的光合菌吸收。反应器在污染甲醛浓度为3.5 mg·m-3的试剂室内运行过程中,其甲醛去除率逐渐上升,室内污染甲醛浓度逐渐降低,运行31 d后室内甲醛浓度降为0.04 mg·m-3(低于国标值),其净化甲醛污染的CADR(clean air delivery rate)值达到481.4 m3·h-1,沼泽红假单胞菌细胞的存活率为98%,说明固定沼泽红假单胞菌具有应用于室内甲醛污染去除的应用潜力。 相似文献
19.
《Atmospheric environment (Oxford, England : 1994)》2007,41(15):3203-3216
The diffusion coefficient, D, partition coefficient, K, and the initial volatile organic compounds (VOCs) in dry building materials, are the three key parameters used to predict the VOC emissions. D and K may be strongly affected by temperature. We have developed a new and simple method, the C-history method, to measure the diffusion coefficient, D and the partition coefficient, K of formaldehyde in dry building materials at temperatures of 18, 30, 40 and 50 °C. The measured variations of the diffusion coefficients and the partition coefficients with temperature for particle board, vinyl floor, medium- and high-density board are presented. A formula relating the partition coefficient and related factors is obtained through analysis. This formula can predict the partition coefficient in principle and provide an insight for fitting experimental data, and it agrees well with the experimental results. 相似文献
20.
Skjøth CA Ellermann T Hertel O Gyldenkaerne S Mikkelsen MH 《Journal of the Air & Waste Management Association (1995)》2008,58(9):1158-1165
Releases of ammonia (NH3) to the atmosphere contribute significantly to the deposition of nitrogen to both terrestrial and aquatic ecosystems. This is the background for the national NH3 emission ceilings in Europe. However, in some countries the national legislation aims not only to meet these ceilings but also to reduce the atmospheric nitrogen deposition to local ecosystems. Such measures to reduce the load of nitrogen to local ecosystems were introduced in Denmark in 1994. In this paper we demonstrate that this regulation is reflected in the NH3 concentrations in Denmark. The Danish legislation forces farmers to applying manure to the fields during the crop-growing season. We have analyzed the seasonal variation in local NH3 concentrations over the time period of 1989-2003. During this period the seasonal variation has changed from having moderate spring and autumn concentration peaks to having a single and much more pronounced spring peak. In the analysis we apply an NH3 emission model to demonstrate that these changes in the seasonal variation are a result of the changes in the Danish legislation. The analysis demonstrates the strength of using a high-resolution emission model in the analysis of routine monitoring data. 相似文献