Valdés H  Zaror CA 《Chemosphere》2006,65(7):1131-1136
Ozone oxidation combined with activated carbon adsorption (O(3)/AC) has recently started to be developed as a single process for water and wastewater treatment. While a number of aspects of aqueous ozone decomposition are well understood, the importance and relationship between aqueous ozone decomposition and organic contaminant degradation in the presence of activated carbon is still not clear. This study focuses on determining the contribution of homogeneous and heterogeneous reactions to organic contaminants removal in O(3)/AC system. Benzothiazole (BT) was selected as a target organic pollutant due to its environmental concern. A reactor system based on a differential circular flow reactor composed by a 19 cm(3) activated carbon fixed bed column and 1 dm(3) storage tank was used. Ozone was produced from pure and dry oxygen using an Ozocav ozone generator rated at 5 g O(3)h(-1). Experimental results show that BT removal rate was proportional to activated carbon dosage. Activated carbon surface contribution to BT oxidation reactions with ozone, increased with pH in absence of radical scavengers. The radical reaction contribution within the pH range 2-11 accounted for 67-83% for BT removal in O(3)/AC simultaneous treatment. Results suggest that at pH higher than the pH of the point of zero charge of the activated carbon dissociated acid groups such as carboxylic acid anhydrides and carboxylic acids present on activated carbon surface could be responsible for the observed increase in the ozone decomposition reaction rate. A simplified mechanism and a kinetic scheme representing the contribution of homogeneous and heterogeneous reactions on BT ozonation in the presence of activated carbon is proposed.  相似文献   

2.
采用臭氧/活性炭联合工艺对焦化废水A2/O出水进行深度处理。考察了溶液初始pH值、臭氧投加量、活性炭投加量及使用次数、反应时间对焦化废水处理效果的影响。实验结果表明,活性炭的使用可显著提高臭氧对焦化废水COD的去除率,在溶液初始pH值为10.25、臭氧投加量为7.5 mg/min、活性炭投加量50 g/L、反应时间为30 min条件下,COD去除率达到73.51%。同时,在活性炭重复使用10次时,COD去除率为70.85%,仅降低了2.66%。  相似文献   

3.
Ozonation of three different synthetic pharmaceutical formulation wastewater containing two human antibiotics and a veterinary antibiotic has been studied to enhance the their biodegradability. The effects of pH and initial chemical oxygen demand (COD) value as well as addition of hydrogen peroxide on ozonation process were investigated. Total organic carbon (TOC), COD, biochemical oxygen demand (BOD), and aromatic content (UV254) were the parameters followed to evaluate the performance of ozonation process. Comparison of the biodegradability of selected wastewaters containing different antibiotics confirmed that the variation of biodegradability was associated with the target compound. While BOD5/COD ratio of veterinary antibiotic formulation wastewater was increased from 0.077 to 0.38 with an applied ozone dosage of 2.96 g/l, this ratio for human antibiotic I and human antibiotic II was increased from 0 to 0.1 and 0.27 respectively. Moreover the results of this investigation showed that the ozonation process is capable of achieving high levels of COD and aromaticity removals at about their natural pH values.  相似文献   

4.
Ning B  Graham NJ  Zhang Y 《Chemosphere》2007,68(6):1163-1172
This aqueous reaction between ozone and two alkylphenols (APs), namely octylphenol (OP) and nonylphenol (NP), has been investigated. Both compounds are important endocrine disrupting chemicals, which arise from the biodegradation of alkylphenol ethoxylates and are often found at relatively high concentrations in wastewater effluents. In this paper the results of an experimental study are presented which provide values for the reaction rate constants between molecular ozone and undissociated OP and NP, and overall reaction rate constants for the degradation of the two APs at pH values in the range of 7-9. The kinetic rate constants for OP and NP degradation by molecular ozone were 4.33(+/-0.18) x 10(4) and 3.90(+/-0.10) x 10(4) M(-1) s(-1), and the reaction stoichiometry was similar in both cases and equal to approximately 1.3:1 ([O3]:[AP]). The overall second order reaction rate constants for the two APs increased significantly with increasing pH, which is believed to be mainly due to the increasing influence of indirect radical reaction with increasing pH; this aspect is considered in more detail in a companion paper. A preliminary investigation of the reaction mechanism suggests that an initial product of ozonation is hydroxyl-alkyl phenol.  相似文献   

5.
对臭氧氧化去除焦化废水生化出水COD的反应动力学及其影响因素进行了实验研究,结果表明,在臭氧投加量为8.50mg/min,反应温度为20'E和初始pH为10.61条件下,对COD的降解符合表观一级反应动力学模型,其相关系数R。=0.9991,表观反应速率常数k。。=1.01×10^-3s-1。该条件下,臭氧氧化对COD的降解主要来源于高活性羟基自由基的强氧化作用。在不同的臭氧投加量(4.25~12.75mg/min)、不同的反应温度(10~40℃)和不同的初始pH(3.76~12.53)下,COD的降解也同样遵循一级反应动力学规律。随着臭氧投加量的增大,COD降解的表观反应速率常数从(0.554×10^-3)s-1增加到(1.06×10&-3)s-1;随着反应温度的升高,表观反应速率常数从(0.427×10^-3)s-1增加到(1.40×10-3)s-1,温度越高反应速率提高的幅度却越小;在初始pH3.76~10.61范围内,表观反应速率常数从(0.218×10^-3)s-1增加到(1.01×10^-3)s-1,在初始pH为12.53时表观反应速率常数下降到(0.857×10^-3)s-1。  相似文献   

6.
This study investigated the removal of parabens, N,N-diethyl-m-toluamide (DEET), and phthalates by ozonation. The second-order rate constants for the reaction between selected compounds with ozone at pH 7 were of (2.2 +/-0.2) X 10(6) to (2.9 +/-0.3) X 10(6) M 1/s for parabens, (2.1+/- 0.3) to (3.9 +/-0.5) M-1/s for phthalates, and (5.2 +/-0.3) M-1/s for DEET. The rate constants for the reaction between selected compounds with hydroxyl radical ranged from (2.49 +/-0.06) x 10(9) to (8.5 +/-0.2) x 10(9) M-1/s. Ozonation of selected compounds in secondary wastewater and surface waters revealed that ozone dose of 1 and 3 mg/L yielded greater than 99% depletion of parabens and greater than 92% DEET and phthalates, respectively. In addition, parabens were found to transform almost exclusively through the reaction with ozone, while DEET and phthalates were transformed almost entirely by hydroxyl radicals (.OH).  相似文献   

7.
Ozonation characteristics of synthetic Procaine Penicillin G (PPG) formulation effluent were investigated in a semi-batch ozone reactor at different pH (3, 7 and 12), ozone feed rates (600-2600 mg h-1) and COD values (200-600 mg l-1). Ozonation of aqueous PPG effluent resulted in 37 (82)% COD removal after 60 (120) min ozonation when the reaction pH was kept constant at pH=7.900 mg l-1 (corresponding to 50% of the total introduced) ozone was absorbed during a reaction period of 1 h. The effects of increasing the applied ozone dose and the initial COD on the COD abatement rates of PPG effluent were also studied. Results have indicated that increasing the ozone dose and decreasing the COD content both have positive effects on COD removal rates. The significant contribution of the free radical (.OH) reaction pathway to PPG ozonation could be traced using tert-butyl alcohol as the .OH probe compound at varying concentrations. The bimolecular reaction rate constants for the direct reaction of PPG with ozone were found as 152 and 2404 M-1 h-1 at pH=3 and 7, respectively, using the gas phase ozone partial pressures determined from of the outlet gas stream analysis. It could be demonstrated that ozone decomposition to free radicals being triggered by increasing the pH from 3 to 7 is essential for the rate enhancement of PPG effluent ozonation.  相似文献   

8.
Determination of antibiotic compounds in water by on-line SPE-LC/MSD   总被引:2,自引:0,他引:2  
Choi KJ  Kim SG  Kim CW  Kim SH 《Chemosphere》2007,66(6):977-984
This study attempts to provide an improved approach for the analysis of antibiotics, which normally exist at low concentration in complex matrices such as receiving streams of wastewater treatment plant discharge. The analytical method developed in this study combines an existing pretreatment technique of solid-phase extraction (SPE) with liquid chromatography mass spectrometry (LC/MSD) through on-line connection. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 ml water samples, recoveries were between 74.3% and 116.5% and average LOQ was 0.11 microg l(-1) for the sulfonamide antibiotics (SA) and 0.09 microg l(-1) for the tetracycline antibiotics (TA). Application of the developed method for the analysis of fourteen antibiotics revealed that several antibiotics were detected at concentrations above the LOQ in ARW. Treated and untreated sewage and agricultural wastewater were mostly responsible for the antibiotics contamination of the river. Antibiotics were detected at much higher concentrations in the agricultural wastewater sample than in the sewage sample, implying substantial use of antibiotics in the agricultural industry. Wastewater treatment was generally effective in separation of the antibiotics tested in this study. The extent of the treatment depended on the type of antibiotics. Hydrophobic antibiotics were more effectively separated from the solution than hydrophilic antibiotics.  相似文献   

9.
Liu C  Nanaboina V  Korshin G 《Chemosphere》2012,86(8):774-782
This study examined effects of ozonation on thirteen fluoroquinolone, macrolide and lincosamide antibiotics present in municipal wastewater. Transformations of effluent organic matter (EfOM) caused by ozonation were characterized using absorbance/fluorescence spectroscopy and high performance size exclusion chromatography (HPSEC). Concentrations of aldehydes and carboxylic acids generated via the oxidation of EfOM were also determined. The absorbance and fluorescence of ozonated wastewater decreased with increasing ozone dose or treatment time. HPSEC data showed that these phenomena corresponded to the oxidation of all EfOM fractions, with some preference towards the degradation of the EfOM molecules with high apparent molecular weight. The removal of antibiotics and production of aldehydes and carboxylic acids were strongly correlated with the changes in both EfOM absorbance and fluorescence. Applications of a model describing the concurrent degradation of trace level contaminants and relative changes of EfOM emission allowed achieving a good fitting between the experimental and modeled ΔC/C0 vs. ΔA/A0 and ΔC/C0 vs. ΔF/F0 data.  相似文献   

10.
The behaviour of residues of antibiotic drugs during bank filtration was studied at a field site in Berlin, Germany, where bank-filtered water is used for the production of drinking water. The neighbouring surface water used for bank filtration is under the influence of treated municipal wastewater. Seven out of 19 investigated antimicrobial residues were found in the surface water with median concentrations between 7 and 151ngL(-1). Out of the seven analytes detected in the surface water only three (anhydroerythromycin, clindamycin and sulfamethoxazole) were found with median concentrations above their limits of quantitation in bank filtrate with a travel time of one month or less. With the exception of sulfamethoxazole, none of the 19 analytes were present in bank filtrate with a residence time larger than one month or in the water-supply well itself. Sulfamethoxazole found with a median concentration of 151ngL(-1) in the surface water was the most persistent of all antimicrobial residues. Nevertheless, it was also removed by more than 98% and only found with a median concentration of 2ngL(-1) in the water-supply well. The degradation of clindamycin and sulfamethoxazole appear to be redox-dependent. Clindamycin was eliminated more efficiently under oxic infiltration conditions while sulfamethoxazole was eliminated more rapidly under anoxic infiltration conditions. A slight preference for an improved degradation under oxic (clarithromycin and roxithromycin) or anoxic (anhydroerythromycin) conditions was also observed for the macrolide antibiotics. Nevertheless, all macrolides were readily removable by bank filtration both under oxic and anoxic conditions.  相似文献   

11.
探讨了臭氧氧化技术处理染料 (酸性、直接、活性、分散和还原颜料 )模拟废水的影响因素———pH值、初始浓度和臭氧含量等对其的影响 ;臭氧氧化能提高染料废水的可生化性 ,可用来作为高浓度染料废水的预处理手段  相似文献   

12.
臭氧氧化法处理苯酚废水的影响因素分析   总被引:5,自引:0,他引:5  
将含臭氧的气体通入模拟苯酚废水,其反应过程受到很多因素的控制,比如各种反应物的投加量、投加方式、以及溶液的环境因素,如溶液pH、温度和影响反应(加速或促进)的物质存在等。文中通过实验评估各影响因素对其影响的程度,可为苯酚废水处理的实际应用提供指导和参考。  相似文献   

13.
The degradation of bitertanol by ozone treatment is investigated. Solutions of bitertanol (8.4 μg mL?1) were prepared either by dissolution of the standard or by dilution of Gaucho Blé seed loading solution and then ozonated under different conditions. Evolution of the concentrations of bitertanol and its ozonation by-products in both solutions was monitored by HPLC–UV as a function of the treatment time for a concentration of 100 g m?3 of ozone in the inlet gas. Bitertanol degradation was found to follow a pseudo-first order reaction in both cases. However, the rate of the reaction in diluted seed loading solution was much lower (0.19 vs. 0.27 min?1 in standard solution) and was close to the reaction rate observed in the presence of a radical scavenger, tert-butanol (0.11 min?1). Thus, it may be suggested that additives present in the seed loading solution may play the role of radical scavengers. Study of ozone concentration in the inlet gas (from 25 to 100 g m?3) showed that ozone degradation is also a first-order reaction with respect to ozone. Four ozonation by-products were highlighted, collected and identified by HPLC coupled with an ion trap mass spectrometer using positive electrospray ionization mode. A degradation pathway of bitertanol was finally proposed.  相似文献   

14.
Kinetics of quinoline degradation by O3/UV in aqueous phase   总被引:1,自引:0,他引:1  
Wang X  Huang X  Zuo C  Hu H 《Chemosphere》2004,55(5):733-741
The kinetics of quinoline degradation by O3/UV in aqueous phase was studied in this paper. It was found that the stoichiometric factor for the number of ozone molecule consumed by per quinoline molecule was 1. The second-order rate constants at 15 degrees C for the direct reaction of quinoline with ozone and that for the reaction of quinoline with *OH were determined to be 51.0 and 7.24 x 10(9) M(-1)s(-1), respectively. In O3/UV reaction system, *OH was the more important oxidant to degrade quinoline than ozone. For a comparison, in O3 reaction system, the relative importance of the two oxidants depended on the pH value greatly. To make the degradation of quinoline more practical, improvement of the concentration of *OH is more feasible.  相似文献   

15.

The occurrence, distribution, and risk assessment of antibiotics in freshwater systems are receiving global attention, because of their impact on the environment and human health. However, few studies have focused on this topic in Northeast China and its Songhua River, the third-largest river in China. This study investigated the occurrence and distribution of 12 antibiotics, including three cephalosporins (cefazolin, cefmetazole, cefotaxime), three macrolides (azithromycin, clarithromycin, roxithromycin), three fluoroquinolones (ofloxacin, norfloxacin, flumequine), and three sulfonamides (sulfadiazine, sulfapyridine, sulfamethoxazole) in the mainstream and tributaries of the Songhua River. A total of 152 surface water samples were collected in January, May, July, and October 2016. These samples were analyzed using solid-phase extraction (SPE) and ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The results indicated the wide use of all 12 antibiotics in the mainstream of the Songhua River. Sulfamethoxazole and cefazolin were the dominant antibiotics, with maximum concentrations of 73.1 and 65.4 ng L?1, respectively. Other antibiotics were present at mean concentrations below 15 ng L?1, except cefmetazole, present at a mean concentration of 35.6 ng L?1. The spatial distribution of antibiotics showed that unbalanced regional development may lead to the distribution pattern of the antibiotics in the tributaries and the mainstream. Thus study also assessed the seasonal variation of antibiotics in urban surface water; cephalosporin, sulfonamide, fluoroquinolone, and macrolide concentrations were significantly higher during the icebound season than during non-icebound season. This may be due to the low temperature and water flow of the river in winter. Risk assessment showed that azithromycin, clarithromycin, roxithromycin, flumequine, and sulfamethoxazole posed a low or median risk to the aquatic organisms in the mainstream. The potential risks created by antibiotics to the aquatic environment should not be neglected in the Songhua River. The potential risks created by antibiotics to the aquatic environment should not be neglected in the Songhua River.

  相似文献   

16.
This study investigated the dissolution, aggregation, and reaction kinetics of silver nanoparticles (AgNPs) with the three types of water disinfectants (ultraviolet, sodium hypochlorite, and ozone) under the different conditions of pH, ionic strength, or humic acid (HA). The physicochemical changes of AgNPs were measured by using UV–Vis spectroscopy, transmission electron microscopy, and inductively coupled plasma optical emission spectrometer. The results showed that when AgNPs contacted the disinfectants, oxidative dissolution was the primary reaction. In addition, the reaction kinetics studies revealed that the reaction rate of AgNPs with disinfectants was significantly influenced by different disinfectants along with different pH and the presence of sodium nitrate and HA. Our research demonstrated the potential effect of disinfectants on AgNPs, which will improve our understanding of the fate of AgNPs in the disinfection processes in the water and wastewater treatment plant.  相似文献   

17.
双频超声/臭氧联用处理硝基苯类制药废水研究   总被引:2,自引:0,他引:2  
采用臭氧单独氧化、单频超声协同臭氧、双频超声协同臭氧氧化处理硝基苯类制药废水,考察了废水初始pH值、臭氧通入量、超声波频率及功率等因素对处理效果的影响。优化出双频超声协同臭氧处理硝基苯制药废水的最佳处理条件,经处理后的水质能达到《污水综合排放标准》(GB8978-1996)的一级排放标准.  相似文献   

18.
多相催化-臭氧氧化法处理模拟有机磷农药废水   总被引:1,自引:0,他引:1  
实验通过臭氧氧化法来降解模拟废水中的有机磷农药,将其转化为无害物质,并试验研究了在废水中加入2种自制的催化剂对降解结果的影响。采用气相色谱法测定水中有机磷农药的量。结果表明,只用臭氧处理的情况下1周后有机磷的去除率为78.03%;在催化剂A存在下,去除率可达93.85%;在催化剂B存在下,去除率可达为88.35%。结果表明,臭氧氧化法对此类污水具有较好的降解作用,尤其在有催化剂存在的情况下处理效果更好,在室温和中性介质中均属于一级反应。  相似文献   

19.
多相催化-臭氧氧化法处理模拟有机磷农药废水   总被引:12,自引:0,他引:12  
实验通过臭氧氧化法来降解模拟废水中的有机磷农药,将其转化为无害物质,并试验研究了在废水中加入2种自制的催化剂对降解结果的影响。采用气相色谱法测定水中有机磷农药的量。结果表明,只用臭氧处理的情况下1周后有机磷的去除率为78.03%;在催化剂A存在下,去除率可达93.85%;在催化剂B存在下,去除率可达为88.35%。结果表明,臭氧氧化法对此类污水:具有较好的降解作用,尤其在有催化剂存在的情况下处理效果更好,在室温和中性介质中均属于一级反应。  相似文献   

20.
Photo-Fenton-assisted ozonation of p-Coumaric acid in aqueous solution   总被引:1,自引:0,他引:1  
The degradation of p-Coumaric acid present in olive oil mill wastewater was investigated as a pretreatment stage to obtain more easily biodegradable molecules, with lower toxicity that facilitates subsequent anaerobic digestion. Thus, photo-Fenton-assisted ozonation has been studied and compared with ozonation at alkaline pH and conventional single ultraviolet (UV) and acid ozonation treatments. In the combined process, the overall kinetic rate constant was split into various components: direct oxidation by UV light, direct oxidation by ozone and oxidation by hydroxyl radicals. Molecular and/or radical ozone reaction was studied by conducting the reaction in the presence and absence of tert-butylalcohol at pHs 2, 7 and 9. Ozone oxidation rate increases with pH or by the addition of Fenton reagent and/or UV radiation due to generation of hydroxyl radicals, *OH. Hydrogen peroxide and ferrous ion play a double role during oxidation since at low concentrations they act as initiators of hydroxyl radicals but at high concentrations they act as radical scavengers. Finally, the additional levels of degradation by formation of hydroxyl radicals have been quantified in comparison to the conventional single processes and an equation is proposed for the reaction rate as a function of studied operating variables.  相似文献   