首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

2.
Chang MB  Chi KH  Chang SH  Yeh JW 《Chemosphere》2007,66(6):1114-1122
Partitioning of PCDD/F congeners between vapor/solid phases and removal and destruction efficiencies achieved with selective catalytic reduction (SCR) system for PCDD/Fs at an existing municipal waste incinerator (MWI) and metal smelting plant (MSP) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP, operating temperature: 230 degrees C), wet scrubbers (WS, operating temperature: 70 degrees C) and SCR (operating temperature: 220 degrees C) as major air pollution control devices (APCDs). PCDD/F concentration measured at stack gas of the MWI investigated is 0.728 ng-TEQ/Nm(3). The removal efficiency of WS+SCR system for PCDD/Fs reaches 93% in the MWI investigated. The MSP investigated is equipped with EP (operating temperature: 240 degrees C) and SCR (operating temperature: 290 degrees C) as APCDs. The flue gas sampling results also indicate that PCDD/F concentration treated with SCR is 1.35 ng-TEQ/Nm(3). The SCR system adopted in MSP can remove 52.3% PCDD/Fs from flue gases (SCR operating temperature: 290 degrees C, Gas flow rate: 660 kN m(3)/h). In addition, the distributions of PCDD/F congeners observed in the flue gases of the MWI and MSP investigated are significantly different. This study also indicates that the PCDD/F congeners measured in the flue gases of those two facilities are mostly distributed in vapor phase prior to the SCR system and shift to solid phase (vapor-phase PCDD/Fs are effectively decomposed) after being treated with catalyst. Besides, the results also indicate that with SCR highly chlorinated PCDD/F congeners can be transformed to lowly chlorinated PCDD/F congeners probably by dechlorination, while the removal efficiencies of vapor-phase PCDD/Fs increase with increasing chlorination.  相似文献   

3.
Thirty-one samples of baked-salt products used in commercial food additives were analyzed for the presence of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs). Dioxins were highly detected in 12 samples of baked salts. The amount of dioxins found in the samples ranged from 12.47 pg/g to 406.56 pg/g (0.71 pg TEQ/g to 23.51 pg TEQ/g, respectively). The most abundant congeners, as TEQ values, were 2,3,4,7,8-PeCDF; 1,2,3,7,8-PeCDF; and 1,2,3,4,7,8-HxCDF in PCDF congeners and 1,2,3,7,8-PeCDD; 1,2,3,6,7,8-HxCDD; and 1,2,3,7,8,9-HxCDD in PCDD congeners. Meanwhile, PCDDs/PCDFs were analyzed in high-temperature-treated samples of natural sea salt alone and natural sea salt to which di-(2-ethylhexyl)phthalate (DEHP) had been added. In the former case, PCDD/PCDF formation was most evident at temperatures near 450 degrees C, the total amount of dioxins was 90.07 pg/g (6.07 pg TEQ/g), and PCDD congeners comprised less than 50% of the total PCDDs/PCDFs. However, when the latter samples were heated, the total PCDD/PCDF concentration was 512.30 pg/g (21.53 pg TEQ/g), with PCDD congeners comprising over 87% of the total PCDDs/PCDFs.  相似文献   

4.
Liu W  Zheng M  Wang D  Xing Y  Zhao X  Ma X  Qian Y 《Chemosphere》2004,57(10):1317-1323
The occurrence and distribution of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and polychlorinated biphenyls (PCBs) in a typical process of production of 1,4-dichlorobenzene (p-DCB) were investigated systematically in this study. P5CDFs and H6CDFs were the main congeners of PCDD/Fs, while only low levels of other PCDD/Fs were detected in the samples. The concentrations of PCBs were up to 4614 ng/g in the semi-manufactured products, and 1797 ng/g in the product p-DCB. It was also found that high chlorinated PCB congeners increased with the further chlorination. The levels of PCDD/Fs decreased obviously in the purification process, while PCBs could not be removed effectively. Polychlorophenols and other important dioxin precursors (1,4-dichloro-2-phenoxybenzene and 2-phenyl-2',5,5'-trichlorophenol) were also analyzed. Polychlorophenols which ortho- and para-positions of the hydroxyl were substituted by chlorine were the main congeners. In addition, a possible pathway of the formation of PCDD/Fs and PCBs in the production of p-DCB was presented. The results of this article suggest that re-estimation on the risk of using p-DCB products, especially the products for daily use such as mothballs, is expected.  相似文献   

5.
Seventeen polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were quantified in adipose tissue samples of non-occupationally exposed women living in Southern Spain. Geometric mean levels of sum of congeners and WHO(PCDD/F)-TEQ(2005) were 410 and 17.9pgg(-1) fat, respectively. Among PCDDs, octachlorodibenzo-p-dioxin (OCDD) showed the highest concentration with a mean value of 265pgg(-1) fat, followed by 1,2,3,6,7,8-HxCDD (49.3pgg(-1) fat) and 1,2,3,4,6,7,8-HpCDD (45.2pgg(-1) fat). These three congeners were responsible for around 90% of the sum of all PCDD/F congeners in adipose tissue. The geometric mean 2,3,7,8-TCDD value was 1.87pgg(-1) fat. 2,3,4,7,8-PeCDF (8.43pgg(-1) fat) showed the highest concentration among the PCDFs, followed by 1,2,3,4,7,8-HxCDF (4.17pgg(-1) fat) and 1,2,3,6,7,8-HxCDF (3.28pgg(-1) fat), and these three congeners were responsible for 4% of the sum of all studied PCDD/F congeners in adipose tissue and 76% of the sum of ten PCDFs. 1,2,3,7,8,9-HxCDF was the only congener not quantified in any sample, while 1,2,3,4,7,8,9-HpCDF, 1,2,3,7,8-PeCDF, OCDF and 2,3,7,8-TCDF were found in 5, 16, 16 and 19 samples, respectively. All other congeners were quantifiable in all 20 samples. Congeners contributing most to the WHO(PCDD/F)-TEQ(2005) were 1,2,3,7,8-PeCDD (31.6%), 1,2,3,6,7,8-HxCDD (28.3%) and 2,3,4,7,8-PeCDF (14.6%). The body burden of log-transformed WHO(PCDD/F)-TEQ(2005) levels increased with age (B=0.02; 95% CI=0.01, 0.03; p=0.02). Although these adipose tissue PCDD/F levels are similar to previously published findings in Spain and other European countries, further research is needed to determine trends in the exposure of women to these chemical residues.  相似文献   

6.
Pandelova M  Lenoir D  Schramm KW 《Chemosphere》2006,62(7):1196-1205
In the flue gas of co-combustion of solid waste and coal in a laboratory scale furnace high concentrations of polychlorinated dibenzo-p-dioxin and furans (PCDD/F), polychlorinated biphenyls (PCB) and polychlorinated benzenes (PCBz) have been detected. These toxic emissions have been reduced by the help of various inhibitors added to fuel before incineration. Knowledge of the congener pattern and homologue profiles of PCDD/F, PCB and PCBz is important to elaborate the mechanism of formation and inhibition of the toxic compounds formed during co-combustion of solid waste and coal. Principle component analysis (PCA) is used in order to find the similarity between the samples and separate them according their toxicity. By the help of the component analysis (CA) the best correlated congeners are effectively detected. Using linear regression between the independent variables and the indicator parameters various good correlated pairs between PCDD/F, PCB and PCBz have been elaborated. Generally it was found that the samples with higher toxicity show a good correlation between tetra- and pentachlorinated benzenes and tetra- and pentachlorinated dibenzo-p-furans. The best indicator parameter for PCDD/F World Health Organization toxic equivalent (WHO-TEQ) among the PCBz congeners investigated is 1,2,4,5-TCBz. This isomer is also significantly correlated with PCDD/F WHO-TEQ and with the sum of PCDD/F WHO-TEQ and PCB WHO-TEQ. However for samples with higher percentage of inhibitors the above mentioned relationship between the surrogate and WHO-TEQ disappeared. The PCB homologues and congeners show no correlation with PCBz and PCDD/F homologues and congeners.  相似文献   

7.
Spruce (Picea abies (L.) Karst.) needles were exposed to exhaust gas containing polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) generated by combustion of polyvinyl chloride, wood, high-density polyethylene, and styrene. Photodegradation of PCDD/Fs adsorbed on spruce needles under sunlight irradiation was studied. The photodegradation of PCDD/Fs follows pseudo-first-order reaction kinetics, with photolysis half-lives ranging between 40 and 100 h. The photolysis rates of PCDF congeners are higher than PCDD congeners with the same chlorinated substitutions. Higher chlorinated PCDD/Fs tend to photolyze slowly. The wax components in spruce needles may act as proton donors and accelerate the photolysis rate. C-Cl cleavage through the addition of protons to PCDD/F molecules may be an important route for PCDD/Fs photodegradation.  相似文献   

8.
OBJECTIVE: To observe how PCDD/F and Co-PCB concentrations in breast milk relate to infant birthweights in Tokyo, Japan. STUDY DESIGN: Breast milk samples were collected from 240 mothers (aged 25-34years old) residing in Tokyo to measure the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs; 14 congeners), polychlorinated dibenzofurans (PCDFs; 15 congeners), and coplanar polychlorinated biphenyls (Co-PCBs; 12 congeners) in the breast milk fat. Individual milk samples (about 50ml) were obtained 30days after delivery, between the months of June and September in 1999 and 2000. The relationship of the infant birthweights with the PCDD/F and Co-PCB concentrations was observed. RESULTS: The birthweights were negatively correlated the concentrations of many of the PCDD/F and Co-PCB congeners, with the mean toxic equivalent quantities (TEQs) of the Co-PCBs, and with the sum of the PCDD, PCDF and Co-PCBs, although their correlation coefficients were less than 0.200. Multiple regression analysis showed octachlorodioxin was statistically significant explanatory variate. CONCLUSIONS: There were slight relationship between the dioxins levels of breast milk and the birthweights of the infants.  相似文献   

9.
Ambient air monitoring of PCDD/Fs and co-PCBs in Gyeonggi-do, Korea   总被引:3,自引:0,他引:3  
Kim DG  Min YK  Jeong JY  Kim GH  Kim JY  Son CS  Lee DH 《Chemosphere》2007,67(9):1722-1727
We started the monitoring for PCDD/Fs in ambient air and soil in August 2001, and co-PCBs in January 2002. Decreasing of PCDD/Fs and co-PCBs levels in ambient air were observed. The higher PCDD/Fs levels were found in winter and lower in autumn. We found that the industrial incinerators influenced the PCDD/Fs levels in ambient air. In the 2,3,7,8-substituted PCDD/Fs concentration profiles, the three major congeners occupied 67% of the total mass. In case of co-PCBs, PCB#118, #105 and #77 were observed as the main congeners. Five cluster groups discriminated by ratio of four components, O(8)CDD, 1,2,3,4,6,7,8-H(7)CDD, 1,2,3,4,6,7,8-H(7)CDF and O(8)CDF, were obtained from HCA (hierarchical cluster analysis).  相似文献   

10.
Hsu JF  Guo YL  Yang SY  Liao PC 《Chemosphere》2005,61(9):1231-1243
In 1978-1979, a mass poisoning occurred in central Taiwan from rice-bran oil contaminated by heat-degraded PCBs was later called the Yucheng (oil disease in Chinese). Only a few studies have so far investigated the levels of specific polychlorinated biphenyl (PCB) or polychlorinated dibenzodioxin/furan (PCDD/F) congeners in the Yucheng victims. This study aimed to investigate the serum residual levels of thirty-three PCBs and seventeen 2,3,7,8-substituted PCDD/F congeners in the Yucheng victims 15 years after the exposure. Forty-one blood samples were collected from individual Yucheng victims in 1994-1995. The mean levels of total 33 PCBs and 17 PCDD/Fs were 2468 ng/g lipid (13.3 ng/g sample) and 6550 pg/g lipid (30.9 pg/g sample) respectively. The higher levels were found in PCBs #99, #138, #153, #156, #170, #179, and #180 among 33 PCB congeners, while 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, and OCDD had the higher concentrations among 17 PCDD/F congeners. The total TEQ was contributed in decreasing order by 10 PCDFs (44%), three non-ortho-PCBs (24%), six mono-ortho-PCBs (20%), and seven PCDDs (12%). The mean total PCB levels and TEQ value of the 17 PCDD/Fs in the Yucheng victims 15 years after the toxic exposure were still 9 and 46 times higher than those in the general population in Taiwan. Principle component analysis (PCA) indicated that seven PCB congeners, PCBs #99, #138, #153, #156, #170, #179, and #180, accounted for 73% of the total variances in PCBs. On the other hand, six PCDD/F congeners, 2,3,4,7,8-PeCDF, 1,2,3,4,7,8-HxCDF, 1,2,3,6,7,8-HxCDF, 1,2,3,6,7,8-HxCDD, 1,2,3,4,6,7,8-HpCDF, and OCDD, accounted for 97% of the total variances in PCDD/Fs. In addition, PCA revealed that at least three characteristic patterns of congener profiles for PCBs were observed among the Yucheng victims. Similar trend was also observed for PCDD/Fs. These patterns may reflect distinctive exposure scenarios and/or different metabolizing capabilities among the Yucheng victims. We suggest that these patterns, in contrast to total PCB and PCDD/F levels, may be valuable for the future epidemiologic studies when linking exposure with specific health effect.  相似文献   

11.
Atmospheric concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) compounds were investigated at three different regions of Istanbul which reflect urban, urban/industrial, and sub-urban characteristics. Air samples were collected simultaneously for both gaseous and particulate phases using high volume samplers on monthly time intervals from May 2011 to October 2012. The highest concentrations (3,056 fg/m3 and 156 fg I-TEQ/m3) were observed at the sampling site that reflects traffic, residential, and industrial emission source characteristics, while the lowest concentrations (829 fg/m3 and 38 fg I-TEQ/m3) were observed at the sampling point which is far away from centrum and reflects sub-urban characteristics. Concentrations of PCDD congeners were, in general, found to be higher than PCDF congeners, and OCDD, 1,2,3,4,6,7,8-HpCDD/F, and OCDF congeners were recorded to be the most abundant congeners. Winter season concentrations were also found to be higher especially in particulate phase. As a result, combustion processes such as motor vehicles and residential heating equipment were thought to be the principal sources of emissions of PCDD/F compounds when both congener profiles and seasonal variations are considered. Basic statistical evaluation of the data resembled high degree of inverse correlations between PCDD/F concentrations and UV and solar radiation.  相似文献   

12.
Hsi HC  Yu TH 《Chemosphere》2007,67(7):1434-1443
Leachability of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from raw and solidified air pollution control (APC) residues with selected solvents, including acetic acid, simulated acid rain, humic acid, linear alkylbenzene sulfonate (LAS) and n-hexane was investigated. High-chlorinated PCDD/F congeners were observed in all leachates of raw APC residue samples, with the largest total leaching concentration (61.60 ngm(-3); 0.30 ngI-TEQm(-3)) from treatment with humic acid. Low-chlorinated congeners were mainly leached with LAS and n-hexane. Solidification and stabilization (S/S) processes with cement and sulfur-containing chelating agent decreased the leachability of PCDD/Fs by up to 98% with humic acid and LAS as solvents. However, S/S processes enhanced the leachability of both high- and low-chlorinated PCDD/F congeners with n-hexane as the solvent, which largely increased the toxic equivalent quantity of leachates. These results suggest that conventional S/S processes may effectively restrain the release of PCDD/Fs when APC residues are leached with rain water or natural organic compounds (e.g., humic acid), but may have a deteriorated effect when APC residues are leached with nonpolar organic solvents (e.g., n-hexane) coexisting in the landfill sites.  相似文献   

13.
Dalian is a seaside city situated in the northeastern monsoon area of China. For the first time, levels of PCDD/F and PCB congeners in pine (Cedrus deodara) needles of Dalian urban areas were investigated. Two sampling campaigns with 17 sampling points were performed in 2002. The summation of tetra- to octachlorinated PCDD/Fs and summation of 209 PCB congeners in Dalian pine needles averaged 127+/-40 ng/kg (dry) and 4389+/-1575 ng/kg (dry), respectively. Average toxic equivalence (TEQ) for PCDD/Fs and PCBs are 2.1 and 0.4 ng/kg (dry), respectively. The pine needles can differentiate spatial variation of the pollutants. The PCDD/F and PCB levels in Dalian pine needles are low or comparable with other international regions that were not impacted by evident point sources. The data can serve as a base for long-term spatial and temporal studies of PCDD/Fs and PCBs in China.  相似文献   

14.
The concentrations of 17 polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs), and 12 dioxin-like polychlorinated biphenyls (dl-PCBs) were measured in sediment and key species as an initial investigation on PCDD/Fs and dl-PCBs contamination in the Mondego estuary (Portugal). The results demonstrated that the values of the total PCDD/Fs (∑PCDD/Fs) concentrations were considerably lower than those of the sum of dl-PCBs (∑dl-PCBs) in all the studied samples. Regarding the contribution of individual congeners, OCDD was the predominant PCDD/F and the mono-ortho PCB 118 and PCB 105 were the dominant PCBs in the majority of the samples. Our results suggest that PCDD/Fs and PCBs behave quite differently along the aquatic food web: ∑PCDD/Fs concentrations were lower in higher trophic-level organisms with fish presenting a distinct PCDD/Fs congeners profile; on the contrary, the higher ∑dl-PCBs values were found in upper-level biota, although not exclusively, and quite similar dl-PCBs congener profiles were observed in nearly all the studied species.  相似文献   

15.
Hu SW  ChangChien GP  Chan CC 《Chemosphere》2004,55(4):611-620
This study monitored ambient air concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in three municipal waste incineration plants. Blood PCDD/Fs levels of 133 workers randomly selected from these plants were also measured. The associations between workers' blood PCDD/Fs concentrations and occupational exposures to PCDD/Fs were assessed. Means of air PCDD/Fs levels ranged from 0.08 to 3.01 pg/m3 in international toxic equivalents (I-TEQ). The geometric means of blood PCDD/Fs concentrations were 14.6, 15.8, 19.1 pg/g lipid in World Health Organization (WHO) TEQ, respectively, for workers from three plants. Air levels of total I-TEQ and all congeners, except 2,3,7,8-tetrachlorinated dibenzo-p-dioxin (TeCDD) and 1,2,3,4,7,8,9-heptachlorinated dibenzofuran (HpCDF), were significantly higher in plant B. However, blood concentrations of 2,3,7,8-TeCDD, 1,2,3,7,8-PeCDD, 2,3,7,8-TeCDF, 1,2,3,7,8-PeCDF and 1,2,3,4,7,8,9-HpCDF were significantly elevated in plant C workers. Although job contents, duration of employment and time spent in certain location were significantly different among incineration plants, they were not significantly associated with blood concentrations of any congener. Furthermore, results of the multiple regression analysis that assessed important occupational factors simultaneously and adjusted for potential confounders, showed significant associations between four congeners and incineration plant or job contents. However, the results were limited by small R-squares of the regression models. In conclusion, blood concentrations of several PCDD/Fs congeners were significantly different among three incineration plants. The differences were not explained by the discrepancy in job contents, duration of employment, and time activity in these plants.  相似文献   

16.
Chang MB  Chi KH  Chang-Chien GP 《Chemosphere》2004,55(11):1457-1467
Partitioning of PCDD/F congeners between gaseous and particulate phases and removal efficiencies of the air pollution control devices (APCDs) for PCDD/Fs at an existing municipal waste incinerator (MWI) in Taiwan are evaluated via stack sampling and analysis. The MWI investigated is equipped with electrostatic precipitators (EP), wet scrubbers (WS) and selective catalytic reduction system (SCR) as APCDs. The average PCDD/F concentration of stack gas is 1.49 ng/N m3, and the International Toxic Equivalent Quantity (I-TEQ) is 0.043 ng-I-TEQ/N m3. The EP increases PCDD/F concentration by 174.0% while the average removal efficiency of WS + SCR system for PCDD/Fs reaches 99.1%. In addition, the PCDF removal efficiency achieved with WS + SCR system (97.1–99.8%) is higher than that for PCDDs (96.5–99.3%). The results obtained on gas/particulate partitioning in flue gas indicate that the particulate-phase PCDD/Fs accounted for 65% at the inlet of EP, 20% at the outlet of EP and 50% at the stack, respectively, of the total PCDD/F concentrations. This study also indicates that as the chlorination level of PCDD/F congeners increases, the percentage of PCDD/Fs existing in gas phase decreases in all flue gas samples.  相似文献   

17.
Catalytic oxidation of gaseous PCDD/Fs with ozone over iron oxide catalysts   总被引:2,自引:0,他引:2  
Wang HC  Chang SH  Hung PC  Hwang JF  Chang MB 《Chemosphere》2008,71(2):388-397
Catalytic oxidation of PCDD/Fs (polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans) with ozone (catalytic ozonation) over nano-sized iron oxides (denoted as FexOy) was carried out at temperature of 120-180 degrees C. The effects of operating temperature, ozone concentration, space velocity (SV) and water vapor contents on PCDD/F removal and destruction efficiencies via catalytic ozonation were investigated. High activity of the iron oxide catalyst towards PCDD/F decomposition was observed even at low temperatures with the aid of ozone. The PCDD/F removal and destruction efficiencies achieved with FexOy/O3 at 180 degrees C reach 94% and 91%, respectively. In the absence of ozone, the destruction efficiencies of all PCDD/F congeners are below 20% and decrease with increasing chlorination level of PCDD/F congener at lower temperature (120 degrees C). However, in the presence of ozone, the destruction efficiencies of all PCDD/F congeners are over 80% on FexOy/O3 at 180 degrees C. Higher temperature and ozone addition increase the activity of iron oxide for the decomposition of PCDD/Fs. Additionally, in the presence of 5% water vapor, the destruction efficiency of the PCDD/Fs is above 90% even at lower operating temperature (150 degrees C). It indicates that the presence of appropriate amount of water vapor enhances the catalytic activity for the decomposition of gas-phase PCDD/Fs.  相似文献   

18.
Levels and specific profiles of PCDD/F congeners were determined in bivalve mollusc coming from several Rías (estuarine bays) in Galicia (Spanish northwest Atlantic coast). Three species of bivalve mollusc, Mytilus galloprovincialis, Cerstoderma edulis and Ostrea edulis, from several points of littoral collected in the period from 2000 to 2005 were analysed. WHO-TEQ concentrations ranged from 0.08 to 1.62pgg(-1) wet weight, values below the maximum concentration established by the EU. The PCDD/PCDF congeners profile in the studied samples was dominated by 2,3,7,8-TCDF and 2,3,4,7,8-PeCDF. The possible influence between biometric parameters (fat and condition index) and the culture type of mussel (wild or raft) on PCDDs and PCDFs levels were studied using statistical analysis. The coefficients of Pearson product-moment correlation indicated the existence of positive significant relationship between 2,3,7,8-TCDF and 2,3,4,7,8-PeCDF levels and fat content. There was not correlation between condition index and PCDD/Fs content. ANOVA also revealed there were significant differences between summation operatorPCDD/Fs, 2,3,7,8-TCDF and 2,3,4,7,8-PeCDF levels in raft and wild mussels. Spatial and temporal trends were supported by patterns in ANOVA, using a general linear model (GLM) showing a clear separation in the composition of these compounds in more and less contaminated Rías and a decrease of PCDD/FS levels along the years.  相似文献   

19.
Despite their environmental importance, there are still relatively few historical studies of the environmental occurrence of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), especially in middle Europe. Trends in PCBs and PCDD/Fs were, therefore, assessed in lake sediments of the Grosser Arbersee over the past 130 years (1860-1990). Ballschmiter-PCB concentrations (congeners # 28, 52, 101, 138, 153, 180) increased between 1946 and 1972 from 4.2 to 32.0 microg kg(-1) dry wt, but have since decreased to 25.6 microg kg(-1) dry wt. High chlorinated PCB congeners reached their maxima earlier (1968-1972) than low chlorinated congeners (1985-1991). These trends were consistent with patterns expected from the production and use of PCBs and their precursors. PCDD/F concentrations increased between 1950 from 0.6 microg kg(-1) dry wt to 2.3 microg kg(-1) dry wt in 1977, falling to 1.7 microg kg(-1) dry wt by 1993. PCDF concentrations exceeded those of PCDD until 1968, but afterwards PCDDs (especially OCDD) were predominant. These patterns suggest that domestic heating and waste combustion were the most likely sources, but pollution from local industries, such as metal smelting and glass production, might also have been involved. The data provide a valuable case study from central Europe which confirms the overall declining trends of PCB and PCDD/F contamination shown elsewhere.  相似文献   

20.
To understand the fate of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in a fly ash treatment plant that used the Waelz rotary kiln process (hereafter the Waelz process), the samples of input and output media were collected and analyzed. The most important PCDD/F source in input mass was electric arc furnace (EAF) fly ash, which had a mean PCDD/F content of 18.51 ng/g and contributed more than 99% of PCDD/F input mass, whereas the PCDD/F input mass fractions contributed by the coke, sand, and ambient air were only 0.04%, 0.02%, and 0.000002%, respectively. For the PCDD/F output mass in the Waelz process, the major total PCDD/F contents of 43.73 and 10.78 ng/g were in bag-filter and cyclone ashes, which accounted for approximately 69% and 17%, respectively, whereas those of stack flue gas and slag were 14% and 0.423%, respectively. The Waelz process has a dechlorination mechanism for higher chlorinated congeners, but it is difficult to decompose the aromatic rings of PCDD/Fs. Therefore, this resulted in the accumulation of lower chlorinated congeners. The output/input ratio of total PCDD/F mass and total PCDD/F international toxicity equivalence (I-TEQ) was 0.62 and 1.19, respectively. Thus, the Waelz process for the depletion effect of total PCDD/F mass was positive but minor, whereas the effect for total PCDD/F I-TEQ was adverse overall.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏