首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 19 毫秒
1.
A new synthetic medium has been developed for routine use in laboratory-scale sewage treatment simulation and biodegradation tests, such as OECD guideline 302A & 303A or ISO method 11733. The new medium, Syntho, was designed to meet the following objectives: 1) to be more representative of real sewage than the existing standard OECD synthetic sewage, 2) the COD:N:P ratio and mineral composition must allow a good degree of biological nutrient (N, P) removal, and 3) the medium should result in stable unit operation, including good sludge settling and minimal need for control actions. The IAWQ Activated Sludge Model No. 2 (ASM2,) was used to help design the medium and predict reactor performance for different possible media compositions. The results obtained with Syntho indicate that Continuous Activated Sludge (CAS) units with or without nutrient removal can be operated routinely on this feed. The new medium was also characterized by means of a respiration test. The different influent fractions applied in the model were validated, and a respiration profile indicated that Syntho is a close approximation of real sewage.  相似文献   

2.
Model continuous activated sludge (CAS) plants (Husmann units) were used to study the fate of two commercial, alcohol ethoxylate (AE) surfactants during aerobic sewage treatment. The surfactants were produced by the ethoxylation of an essentially linear C(12-15) alcohol (NEODOL 25) with an average of 7 (C(12-15)EO7) or 3 (C(12-15)EO3) moles of ethylene oxide (EO). Recent analytical developments made it possible to measure levels of AE that included the free alcohol and EO1 oligomers across the CAS system, from the influent feed, on the activated sludge, through to the effluent. Measured concentrations of AE (as C(12-15)EO(0-20)) in the synthetic sewage feeds to the test CAS plants lay in the range 11-13 mg/l. During stable operation at 20 degrees C, an average of 5 microg/l AE were present in the C(12-15)EO7 CAS plant effluent, giving a removal (bioelimination) of >99.9%. When levels of AE on the sludge, and polyethylene glycols (PEGs--an expected biodegradation intermediate) in the effluent and on the sludge were also taken into account, biodegradation was considered to be responsible for >98.7% of the observed removal. During operation at a winter temperature (10 degrees C), an average of 26 microg/l AE were present in the C(12-15)EO7 CAS plant effluent, giving a removal of 99.8%. Biodegradation was estimated to be responsible for >97.2% of the observed removal. During operation at 20 degrees C, an average of 7 microg/l AE were present in the C(12-15)EO3 CAS plant effluent, giving a removal of >99.9%. No analysis for PEG was performed in this case but the low level of AE on the sludge (0.2 mg/g dry solids) suggested that biodegradation was responsible for most of the observed removal. Neither surfactant had any adverse effect on the sewage treatment efficiencies of the CAS plants in terms of dissolved organic carbon (DOC) removal, nitrification or biomass levels.  相似文献   

3.
超声波促进城市生活污泥缺氧/好氧消化的研究   总被引:1,自引:1,他引:0  
本研究将超声波预处理引入城市生活污泥缺氧/好氧消化工艺中,自主设计了容积为30 L的生活污泥超声波-缺氧/好氧消化中试系统并用以实验研究。超声波预处理的参数为超声频率28 kHz,声能密度0.15 W/mL,超声时间10 min,超声间隔12 h,污泥超声比例30%。结果表明,引入超声预处理后,缩短了污泥的稳定时间,提高了污泥的消化效率。污泥消化10 d就已经达到了稳定标准,比未引入超声预处理时缩短了12 d,而MLVSS最大去除率提高了11%,达到了55.10%。超声波的引入,对污泥缺氧/好氧消化系统中污泥上清液溶解性COD(SCOD)的变化趋势影响比较明显,而对上清液的pH、氨氮和TP的变化趋势没有明显影响。  相似文献   

4.
Microbial kinetic analysis of three different types of EBNR process   总被引:3,自引:0,他引:3  
Pai TY  Tsai YP  Chou YJ  Chang HY  Leu HG  Ouyang CF 《Chemosphere》2004,55(1):109-118
The disadvantages of developed biological nutrient removal (BNR) processes (additional energy for liquid circulation and addition of external carbon substrate for denitrification in anoxic zones) were improved by reconfiguring the process into (1) an anaerobic zone followed by multiple stages of aerobic-anoxic zones (TNCU3 process) or (2) anaerobic, oxic, anoxic, oxic zones in sequence (TNCU2 process). These two pilot plants were operated at a recycling sludge ratio of 0.5 without internal recycle of nitrified supernatant. The sludge retention time was maintained at 10 d. The main objective of this study is to analyze the kinetics of different microorganisms in these two processes and A2O process by using the Activated Sludge Model No. 2d. The effective removal efficiency of carbon, total phosphorus and total nitrogen at 87-98%, 92-100% and 63-80%, respectively, were achieved in the testing runs. According to model simulations, the microbial kinetics in the TNCU3 and TNCU2 processes would be affected by different operations. When the step feeding strategy was adopted, the HRT was longer due to the less influent flowrate in the front stages and the microbes would grow in quantities by about 6% in the aerobic reactors. In the followed anoxic reactors, the microbes would decrease in quantities by about 12% due to the dilution effect. The dilution effects in TNCU3 and TNCU2 processes did not take place in A2O process because the recycling mixed liquid from the aerobic reactor to the anoxic reactor still contained particulate components. The XH, XPAO, and XAUT concentrations in the effluent of the last tank were lower when the step-feeding mode was adopted. The TNCU3 and TNCU2 processes could be operated efficiently without nitrified liquid circulation and addition of external carbon substrate for denitrification.  相似文献   

5.
Activated sludge systems are widely used in wastewater treatment. Organic carbon removal and nutrient removal are important for stringent water discharge standards. Therefore, activated sludge systems are widely used to remove carbon, nitrogen and phosphorus in new wastewater treatment systems or upgrades of existing systems. The determination of system compounds and kinetic parameters for modelling of these systems are important. For this purpose, respirometric measurements are used to reveal the electron consumption rate of biomass. In order to determine OUR (oxygen uptake rate) and NUR (nitrate uptake rate) parameters, a laboratory scale activated sludge system, including anaerobic, anoxic and aerobic zones, was developed. The performance of the system was continuously controlled from influent and effluent samples. OUR and NUR measurements indicated the kind of nitrogen-phosphorus removal systems required. Moreover, phosphorus uptake in the anoxic zone was investigated. It was found that phosphorus uptake in the anaerobic zone was related to substrate type consumed biologically. The OUR and NUR were found to be lower than in continuous activated sludge measurements. This may be because the mixed culture of the system affected the system performance, owing to competition between denitrification bacteria and poly-P bacteria.  相似文献   

6.
A six-stage membrane bioreactor (MBR) pilot plant was operated to determine and demonstrate the capability of this process to produce a low-nutrient effluent, consistent with the nutrient reduction goals for the Chesapeake Bay. Biological nitrogen removal was accomplished using a multistage configuration with an initial anoxic zone (using the carbon in the influent wastewater), an aerobic zone (where nitrification occurred), a downstream anoxic zone (where methanol was added as a carbon source), and the aerated submerged membrane zone. The capability to reliably reduce effluent total nitrogen to less than 3 mg/L as nitrogen (N) was demonstrated. A combination of biological (using an initial anaerobic zone) and chemical (using alum) phosphorus removal was used to achieve effluent total phosphate concentrations reliably less than 0.1 mg/L as phosphorus (P) and as low as 0.03 mg/L as P. Alum addition also appeared to enhance the filtration characteristics of the MBR sludge and to reduce membrane fouling. Aeration of the submerged membranes results in thickened sludge with a high dissolved oxygen concentration (approaching saturation), which can be recycled to the main aeration zone rather than to an anoxic or anaerobic zone to optimize biological nutrient removal. Biological nutrient removal was characterized using the International Water Association Activated Sludge Model No. 2d. The stoichiometry of chemical phosphorus removal was also consistent with conventional theory and experience. The characteristics of the solids produced in the MBR were compared with those of a parallel full-scale conventional biological nitrogen removal process and were generally found to be similar. These results provide valuable insight to the design and operating characteristics of MBRs intended to produce effluents with very low nutrient concentrations.  相似文献   

7.
The aim of this study was to expand the International Water Association Activated Sludge Model No. 2d (ASM2d) to account for a newly defined readily biodegradable substrate that can be consumed by polyphosphate-accumulating organisms (PAOs) under anoxic and aerobic conditions, but not under anaerobic conditions. The model change was to add a new substrate component and process terms for its use by PAOs and other heterotrophic bacteria under anoxic and aerobic conditions. The Gdansk (Poland) wastewater treatment plant (WWTP), which has a modified University of Cape Town (MUCT) process for nutrient removal, provided field data and mixed liquor for batch tests for model evaluation. The original ASM2d was first calibrated under dynamic conditions with the results of batch tests with settled wastewater and mixed liquor, in which nitrate-uptake rates, phosphorus-release rates, and anoxic phosphorus uptake rates were followed. Model validation was conducted with data from a 96-hour measurement campaign in the full-scale WWTP. The results of similar batch tests with ethanol and fusel oil as the external carbon sources were used to adjust kinetic and stoichiometric coefficients in the expanded ASM2d. Both models were compared based on their predictions of the effect of adding supplemental carbon to the anoxic zone of an MUCT process. In comparison with the ASM2d, the new model better predicted the anoxic behaviors of carbonaceous oxygen demand, nitrate-nitrogen (NO3-N), and phosphorous (PO4-P) in batch experiments with ethanol and fusel oil. However, when simulating ethanol addition to the anoxic zone of a full-scale biological nutrient removal facility, both models predicted similar effluent NO3-N concentrations (6.6 to 6.9 g N/m3). For the particular application, effective enhanced biological phosphorus removal was predicted by both models with external carbon addition but, for the new model, the effluent PO4-P concentration was approximately one-half of that found from ASM2d. On a PO4-P removal percentage basis, the difference was small, that is, 94.1 vs. 97.1%, respectively, for the ASM2d and expanded ASM2d.  相似文献   

8.
A laboratory-scale continuous-flow system with an anaerobic/anoxic/aerobic configuration was set up to study the effect of oxygen in the internal recycle stream; of particular interest was its performance of denitrifying phosphorus-accumulating organisms (DPAOs). It was found that, by using a degas device, the dissolved oxygen in the nitrate recycle stream was effectively decreased from 0.1 +/- 0.02 to 0.01 +/- 0.01 mg/L. This provided a favorable condition for DPAOs to grow under an anoxic condition and thus be sustained successfully in the system. When the degas device was removed from the system, the dissolved oxygen concentration in the anoxic reactor increased to 0.1 +/- 0.02 mg/L. The proliferation of the denitrifying glycogen-accumulating organisms (DGAOs) population and deterioration of DPAOs performance was observed. The increased population of DGAO/GAOs, which competed for the carbon source with DPAO/ PAOs, resulted in a poor performance of biological phosphorus removal.  相似文献   

9.
A preliminary bench-scale study of parallel University of Cape Town (UCT) biological nutrient removal systems showed improvement in anoxic denitrification rates resulting from prefermentation of a septic (i.e., high volatile fatty acid [VFA] content), phosphorus-limited (i.e., total chemical oxygen demand/total phosphorus [TP] ratio < 40:1) wastewater. Net phosphorus removals due to enhanced biological phosphorus removal (EBPR) were only improved marginally by prefermentation in spite of significant increases in anaerobic phosphorus release, polyhydroxyalkanoate formation, and higher anoxic and aerobic uptakes. This probably was due to the high VFA/TP ratio in the raw influent relative to the VFA requirements for EBPR because enough VFAs were already present for phosphorus removal prior to prefermentation. An additional assessment of prefermentation using parallel UCT systems with step feed of 50% of the influent to the anoxic zone was completed. This second phase quantified the effect of prefermentation in a step-feed scenario, which prioritized prefermentation use to enhance denitrification rather than EBPR. While specific denitrification rates in the anoxic zone were significantly improved by prefermentation, high denitrification in the clarifiers and aerobic zones (simultaneous denitrification) made definitive conclusions concerning the potential improvements in total system nitrogen removal questionable. The prefermented system always showed superior values of the zone settling velocity and sludge volume index and the improvement became increasingly statistically significant when the prefermenter was performing well.  相似文献   

10.
倒置A2/O污水处理工艺的特点及应用实例   总被引:1,自引:1,他引:1  
传统A2/O工艺在保证脱氮效果的同时除磷效果往往不佳。在充分分析传统A2/O工艺的基础上,提出了将缺氧池置于厌氧池前面,厌氧池后设置好氧池的分点进水倒置A2/O工艺。某污水厂的现场试验表明,在COD去除能力与常规A2/O工艺相当的情况下,倒置A2/O工艺的脱氮除磷功能明显优于常规A2/O工艺。  相似文献   

11.
Triclosan is an antimicrobial agent which is widely used in household and personal care products. Widespread use of this compound has led to the elevated concentrations of triclosan in wastewater, wastewater treatment plants (WWTPs) and receiving waters. Removal of triclosan and formation of triclosan-methyl was investigated in activated sludge from a standard activated sludge WWTP equipped with enhanced biological phosphorus removal. The removal was found to occur mainly under aerobic conditions while under anoxic (nitrate reducing) and anaerobic conditions rather low removal rates were determined. In a laboratory-scale activated sludge reactor 75% of the triclosan was removed under aerobic conditions within 150 h, while no removal was observed under anaerobic or anoxic conditions. One percent of the triclosan was converted to triclosan-methyl under aerobic conditions, less under anoxic (nitrate reducing) and none under anaerobic conditions.  相似文献   

12.
以人工配水为研究对象,采用厌氧/好氧/缺氧/好氧交替运行的序批式反应器,研究了(AO)2SBR系统同步脱氮除磷的效果,并结合批式实验讨论了同步脱氮除磷的反应机理。研究结果表明,该系统以厌氧1.5 h、好氧1 h、缺氧3h、好氧0.5 h的方式运行,在DO=2.5 mg/L,SRT=15 d的条件下,具有良好的脱氮除磷效果,配水中的总氮、总磷、COD和总有机碳的去除率分别为96.26%、99.87%、90.46%和85.57%。批式实验表明,合成的内碳源越多,氨氮的硝化越充分,反硝化除磷越多。  相似文献   

13.
实验基于企业污水站的改造工程,研究了MBR对玉米深加工废水的处理效果并对工艺运行参数优化提出建议.结果表明,该工艺对COD的去除率可以达到90%以上,出水稳定在26 mg/L左右;出水NH4-N达到1 mg/L以下;TN去除率达到70%以上,出水TN达到10 mg/L以下,出水完全达到排放标准.通过4种工况的比较,说明在污泥浓度8 g/L左右,曝气池内DO在3 mg/L左右,MBR内DO>4 mg/L,好氧段停留时间13.5 h,并保证3h以上的缺氧段水力停留段时间的条件下,A/O+ MBR工艺可以有效去除玉米深加工废水中的污染物.  相似文献   

14.
Xu Z  Nakhla G  Patel J 《Chemosphere》2006,65(7):1171-1181
Tomato-processing wastewaters are typical of slowly biodegradable high strength wastewaters generated from the food canning industry. Three different samples of influent and three samples of anaerobic effluents corresponding to the three influents collected from an on-site pilot-scale anaerobic/aerobic system were characterized using respirometric methods. Respirometric studies demonstrated that the pretreatment in the anaerobic reactor of the pilot-scale system increased the readily biodegradable fraction from an average of 40% of the SCOD in the influent to 50% of the SCOD in the anaerobic effluent, improved kinetics from an average micro(max) of 1.5d(-1) in the influent to 3.5d(-1) in the anaerobic effluent, and eliminated nutrient deficiency. Furthermore, the system was calibrated and simulated by application of wastewater characterization and biokinetic data derived form respirometric tests of influent and anaerobic effluent in Activated Sludge Model no.1 (ASM1).  相似文献   

15.
一体化生物膜技术处理滨海农村污水   总被引:3,自引:0,他引:3  
对厌氧-3级好氧/缺氧生物膜工艺进行技术改进,并对改进后的"一体化生物膜技术"处理低碳氮比农村生活污水进行了实际应用。新工艺增设了回流泵(回流比2∶1),且厌氧段悬浮填料装填率由原来的15%提高到30%,3级好氧/缺氧段YDT型弹性立体填料装填率依次由原来的50%、40%、25%提高到70%、60%和40%。装置连续稳定运行12个月,平均进水量为18 m3/d,HRT为3.7 d,监测结果表明:对COD、BOD、NH3-N、TN、TP和SS平均去除率分别为75.6%、85.9%、86.7%、63.9%、69.3%和85.5%;出水COD、BOD、NH3-N、TN、TP和SS的平均浓度分别在34.9、8.9、3.4、9.9、0.9和6.9 mg/L以下。改进后出水BOD和TN的去除能力有较大提高,除TP外其他各项指标均达到了设计要求。  相似文献   

16.
Utilization of urban sewage sludge: Chinese perspectives   总被引:3,自引:0,他引:3  

Purpose

Urbanization and industrialization in China has resulted in a dramatic increase in the volume of wastewater and sewage sludge produced from wastewater treatment plants. Problems associated with sewage sludge have attracted increasing attention from the public and urban planners. How to manage sludge in an economically and environmentally acceptable manner is one of the critical issues that modern societies are facing.

Methods

Sludge treatment systems consist of thickening, dewatering, and several different alternative main treatments (anaerobic digestion, aerobic digestion, drying, composting, and incineration). Agricultural application, landfill, and incineration are the principal disposal methods for sewage sludge in China. However, sewage sludge disposal in the future should focus on resource recovery, reducing environmental impacts and saving economic costs.

Results

The reuse of biosolids in all scenarios can be environmentally beneficial and cost-effective. Anaerobic digestion followed by land application is the preferable options due to low economic and energy costs and material reuse.

Conclusion

It is necessary to formulate a standard suitable for the utilization of sewage sludge in China.  相似文献   

17.
Chowdhury N  Nakhla G  Zhu J 《Chemosphere》2008,71(5):807-815
A novel liquid-solid circulating fluidized bed bioreactor (LSCFB) configured with anoxic and aerobic columns and lava rock as the biofilm carrier was used to treat synthetic municipal wastewater. Four different empty bed contact times (EBCTs) of 0.82, 0.65, 0.55, and 0.44 h were examined to optimize nutrient removal capability of the system. The LSCFB demonstrated tertiary effluent quality organic and nitrogen removal efficiencies. Effluent characteristics of the LSCFB were soluble biological oxygen demand (SBOD)10 mg l(-1) and total nitrogen (TN)<10 mg l(-1) at organic loading rate (OLR) of 5.3 kg m(-3)d(-1) and nitrogen loading rate of 0.54 kg Nm(-3)d(-1). Remarkably low yields of 0.14, 0.17, 0.19, and 0.21 g VSS g(-1)COD were observed at OLR of 2.6, 3.2, 4.1 and 5.3 kg COD m(-3)d(-1), where increment of biomass growth and detachment rate were also experienced with increasing OLR. However the system demonstrated only 30% phosphorus removal, and mass balances along the anoxic and aerobic columns showed biological phosphorus removal in the system. Organic mass balance showed that approximately 40% of the influent COD was utilized in the anoxic column and the remaining COD was oxidized in the aerobic column. The system is very efficient in nitrification-denitrification, with more than 90% nitrification of ammonium and overall nitrogen removal in the LSCFB was 70+/-11% even at an EBCT of 0.44 h.  相似文献   

18.
Natural and synthetic estrogens present in municipal wastewater can be biodegraded during treatment, particularly in activated sludge. The objective was to assess the extent of transformation of 17-beta-estradiol (E2) and 17-alpha-ethinylestradiol (EE2) by nitrifying activated sludge and evaluate potential relationships between availability of oxygen, nitrification rate, and estrogen removal. For each batch experiment, two reactors were set up--aerobic and alternating anoxic/aerobic-which were then amended with E2 and EE2 from methanolic stock solutions. The EE2 was persistent under anoxic conditions; under aerobic conditions, the observed level of its removal was 22%. The E2 was readily converted to estrone (El)--faster under aerobic (nitrifying) than anoxic (denitrifying) conditions. During the initial anoxic conditions, a metabolite consistent with 17-alpha-estradiol transiently accumulated and was subsequently removed when the reactor was aerated. Higher removal rates of estrogens were associated with higher nitrification rates, which supports the contention that the nitrifying biomass was responsible for their removal.  相似文献   

19.
采用悬挂链曝气式接触氧化工艺在3个时段内处理城市河道污水,通过采用磷脂法、TTC-脱氢酶活性法和MPN法研究载体表面生物膜特性,来验证装置的水质净化效果。结果表明,进水水质变化幅度较大的时段1内,水质对缺氧区和好氧区内生物膜量及活性有很大冲击,对污染物的去除效果影响不大,COD、NH+4-N、TN和TP的平均去除率分别达到75.9%、80.8%、64.6%和78.3%;进水水质稳定的时段2内,缺氧区和好氧区内生物膜量和活性要高于其他时段,COD、NH+4-N、TN和TP的平均去除率分别达到77.0%、80.6%、69.4%和55.3%;低温运行的时段3内,缺氧区和好氧区内生物膜量和活性都低于其他时段,水质净化效果明显下降,COD、NH+4-N、TN和TP的平均去除率分别为71.1%、68.5%、48.9%和46.6%。  相似文献   

20.
Kong XJ  Li D  Cao LQ  Zhang XM  Zhao Y  Lv Y  Zhang J 《Chemosphere》2008,72(1):59-66
In order to evaluate the municipal sewage treatment systems used at Harbin municipal sewage treatment plant for their pollutant removal efficiency, raw sewage and effluent samples at different treatment stages from the sewage treatment systems were taken, priority pollutants (PPs) were identified and quantified using gas chromatography-mass spectrometry (GC-MS) and inductively coupled plasma-atomic emission spectrograph (ICP-AES). The test results indicated that there were one hundred and fifty species of organic pollutants identified in the raw sewage sample, and only ten species of PPs in all the sewage samples. The levels of dimethyl phthalate (DMP), diethyl phthalate (DEP), dibutyl phthalate (DBP), di-n-octyl phthalate (DnOP) in the sewage samples were 0.779-0.111 microg l(-1), 1.977-0.022 microg l(-1), 6.411-2.194 microg l(-1) and 7.152-2.953microg l(-1), respectively, and most of these phthalate esters (PAEs) were removed through anaerobic/aerobic (A/O) process; The levels of alachlor, acetochlor, atrazine were 0.074-0.021 microg l(-1), 0.160-0.096 microg l(-1) and 0.238-0.184 microg l(-1), respectively, and the total removal efficiency of atrazine was poorest through the sewage treatment systems. The levels of Cu, Cr, Se, Hg, Ni and Zn were 0.0030-0.2327 mg l(-1). It is therefore concluded from these results that the sewage treatment systems were efficient in removing most of the organic and inorganic compounds in this study, and so, the discharged effluent could cause little of the secondary pollution of the aquatic environment.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号