首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.
A jet resonance-enhanced multiphoton ionization (REMPI) monitor was tested on a hazardous-waste-fired boiler for its ability to determine concentrations of polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs). Jet REMPI is a real-time instrument capable of highly selective and sensitive (from parts per billion to parts per trillion) detection of a broad range of aromatic compounds, including a number of air toxic compounds. The PCDD/F toxic equivalency (TEQ) value was derived from a predetermined correlation (R 2 = 0.74) with monochlorobenzene (MClBz). This relationship was applied to nine subsequent jet REMPI on-line measurements of MClBz and parallel, standard extractive sampling for PCDD/F TEQ. For high waste-firing rates, with a range of PCDD/F TEQ values between 3.9 and 6.0 ng TEQ/m3, the TEQ values predicted by jet REMPI had a relative difference of 26% with the standard EPA Method 23 results. At low waste-firing rates (0.9–1.6 ng TEQ/m3), the relative difference increased to 219%. This limited testing shows that jet REMPI has promise as an on-line diagnostic monitor, providing feedback on the effects on PCDD/F emissions of operating parameter changes such as fuel feed interruptions or air pollution control failures.  相似文献   

2.
The performance of four dioxin emission monitors, including two long-term sampling devices, the Dioxin-MonitoringSystem (DMS) and AMESA (the adsorption method for sampling dioxins and furans), and two semireal-time continuous monitors, the resonance ionization with multimirror photon accumulation time-of-flight mass spectrometer (RIMMPA-TOFMS) and the jet resonance-enhanced multiphoton ionization (jet-REMPI) system were tested. A package boiler burning a simulated chlorinated hazardous waste was used for a total of nine tests. Reference samples were collected during each test and analyzed for polychlorinated dibenzodioxins and dibenzofurans (PCDDs/Fs) using gas chromatography mass spectrometry. The PCDD/F concentrations of the reference samples measured by EPA Method 23 ranged from 0.9 to 6.0 ng toxic equivalence (TEQ)/dry standard cubic meter. The relative accuracies achieved by DMS, AMESA, and jet-REMPI varied from 22.6% to 78.2%, with 100% data completeness. The RIMMPA-TOFMS produced no quantifiable results due to various difficulties associated with the instrument during the testing. The two long-term samplers were easy to install and operate and provided a cumulative, averaged emission for the sampling period. The operations of the two semi-real-time continuous monitors were relatively complex, but one of them provided on-site, real-time data for PCDD/F emissions from measurement of a TEQ correlative indicator compound. This article summarizes results from the individual Environmental Technology Verification reports for the four dioxin monitors. This work was presented, in part, at the Fourth International Conference on Combustion, Incineration/Pyrolysis and Emission Control (i-CIPEC)  相似文献   

3.
The 2,3,7,8-TODD Toxicity EQuivalents (TEQ) approach provides a useful method for estimating the environmental risk of polychlorodibenzodioxin and polychlorodibenzofuran complex mixtures, thus making it possible to express their toxicological significance with only one number. Generally the conversion of the concentration units into those of TEQ requires an isomer-specific analysis and the appropriate Toxicity Equivalency Factors (TEF). In this paper we propose a “theoretical” model for estimating TEQ values of PCDD + PCDF mixtures which, starting from the experimental value of the PCDD + PCDF concentration (μg Nm−3) and the theoretical value of PCDD and PCDF fingerprints in the emissions from municipal incinerators, to make an estimate of the global toxicity in terms of ng TEQ Nm−3. The TEQ values estimated for a number of samples are in good agreement with those calculated from the isomer and congener experimental data. Given the investment and running costs plus the time and the analytical complexity in determining the congeners and single isomer concentrations, it seems that the proposed “theoretical” model is a reasonable tool for estimating the exposure hazard related to a complex mixture of PCDD/PCDFs emitted from municipal solid waste (MSW) incinerators. Another objective of this paper is to explore the consistency between scientific knowledge and the authority regulatory guidelines. This work shows that the Italian national emission standard (4 μg Nm−3) for the total PCDD+PCDF concentration is higher than the international target of 0.1 ng TEQ Nm−3. We suggest a value of 1 μg Nm−3 for TCDD + TCDF concentration if Italian regulators want to add a further constraint.  相似文献   

4.
Floor dusts from Vietnamese end-of-life vehicle (ELV)-processing households were investigated to elucidate the contamination levels and exposure risk of polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and dioxin-related compounds (DRCs). The concentrations were in order of PBDEs (260–11,000, median 280 ng/g overall) > PCBs (19–2200, median 140 ng/g) > dioxin-like PCBs (8.8–450, median 22 ng/g) ? polybrominated dibenzo-p-dioxin/dibenzofurans (PBDD/Fs, 2000–28,000, median 8500 pg/g) > polychlorinated dibenzo-p-dioxin/dibenzofurans (PCDD/Fs, 440–4100, median 1800 pg/g) > MoBPCDD/Fs (1.9–1200, median 250 pg/g). Concentrations of PCBs and DRCs were higher than those reported for Vietnamese urban houses, indicating ELV processing as a significant source of these contaminants. Higher concentrations of PCBs relative to PBDEs suggest the abundance of old electrical capacitors/transformers in ELVs. The PBDD/F and PCDD/F profiles were indicative of DecaBDE-containing materials and combustion sources, respectively. PBDFs, PCDFs and DL-PCBs were the most important dioxin-like toxic equivalent (TEQ) contributors. The estimated PCB and TEQ intake doses from dust ingestion approached or exceeded the reference doses for children living in some ELV-processing households, indicating potential health risk. More comprehensive risk assessment of the exposure to PCBs and DRCs is required for residents of informal ELV recycling sites.  相似文献   

5.
Air emissions and residual ash samples were collected and analyzed during experiments of open, uncontrolled combustion of electronic waste (e-waste), simulating practices associated with rudimentary e-waste recycling operations. Circuit boards and insulated wires were handled separately to simulate processes associated with metal recovery. The average emissions of polychlorinated dibenzodioxins and dibenzofurans (PCDD/PCDFs) were 92 ng toxic equivalency (TEQ)/kg [n = 2, relative standard deviation (RSD) = 98%] and 11 900 ng TEQ/kg (n = 3, RSD = 50%) of the initial mass of the circuit boards and insulated wire, respectively. The value for the insulated wire is about 100 times higher than that for backyard barrel burning of domestic waste. The emission concentrations of polybrominated dibenzodioxins and dibenzofurans (PBDD/PBDFs) from the combustion of circuit boards were 100 times higher than for their polychlorinated counterparts. Particulate matter (PM) sampling of the fly ash emissions indicated PM emission factors of approximately 15 and 17 g/kg of the initial mass for the circuit boards and insulated wire, respectively. Fly ash samples from both types of e-waste contained considerable amounts of several metallic elements and halogens; lead concentrations were more than 200 times the United States regulatory limits for municipal waste combustors and 20 times those for secondary lead smelters. Leaching tests of the residual bottom ash showed that lead concentrations exceeded U.S. Environmental Protection Agency landfill limits, designating this ash as a hazardous waste.  相似文献   

6.
Typical thermal fingerprints are rather evenly composed of all available polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) congeners, a feature also linked with CuCl2-catalysis. Conversely, chlorophenol condensation patterns are supported strongly by CrCl3-, ZnCl2- and CdCl2-catalysis; they feature selective formation of, e.g., 1,3,6,8- and 1,3,7,9-TCDD arising from mainly 2,4,6-trichlorophenol, a chlorophenol well-represented in incinerator flue gas. Just few, well-defined PCDD-congeners steadily emerge from chlorophenols. Surprisingly, it is experimentally established that these are not generally formed by parallel processes. Additionally, the formation of four important 2,3,7,8-substituted TCDD/F- and PeCDD/F-congeners is statistically quasi-unrelated. Apparently, external (α) or lateral (β)-chlorination occurs as a chance event, contrary to observations and hypotheses in earlier studies. These statements are corroborated by selected congener-to-congener representations. For performing this statistical analysis, simple techniques are followed. Cross-correlation matrices show a relationship for each pair of PCDD/F-congeners in a particular data set: PCDD/F-congener pairs statistically correlate, anti-correlate, or appear rather neutral. In this paper, these novel concepts were applied on data, established during tests on Model Fly Ash (MFA); principal component analysis was used to demonstrate the relevance of MFA-data in relation to municipal solid waste incineration signatures.  相似文献   

7.
The toxic equivalency (TEQ) values of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) are predicted with a model based on the homologue concentrations measured from a laboratory-scale reactor (124 data points), a package boiler (61 data points), and operating municipal waste incinerators (114 data points). Regardless of the three scales and types of equipment, the different temperature profiles, sampling emissions and/or solids (fly ash), and the various chemical and physical properties of the fuels, all the PCDF plots showed highly linear correlations (R(2)>0.99). The fitting lines of the reactor and the boiler data were almost linear with slope of unity, whereas the slope of the municipal waste incinerator data was 0.86, which is caused by higher predicted values for samples with high measured TEQ. The strong correlation also implies that each of the 10 toxic PCDF congeners has a constant concentration relative to its respective total homologue concentration despite a wide range of facility types and combustion conditions. The PCDD plots showed significant scatter and poor linearity, which implies that the relative concentration of PCDD TEQ congeners is more sensitive to variations in reaction conditions than that of the PCDF congeners.  相似文献   

8.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are emitted in trace amounts from municipal solid waste (MSW) incinerators. The exposure to PCDD/Fs experienced by an individual is dominated by the food chain pathway, which accounts for over 98% of the total uptake. Defining a target daily intake (the World Health Organization TDI of 10 pg I-TEQ kg.bw−1day−1) exposure assessment algorithms were then applied to arrive at the corresponding PCDD/F levels in air, soil, plants, food products, etc., which would allow the target intake to be met while retaining the balance of intake between the various exposure pathways. These concentrations were converted to an ambient air concentration of PCDD/Fs and ultimately, by defining criteria for acceptability, to a guide value for PCDD/F concentration in emissions from the MSW incinerator. This strategy was applied to PCDD/F emissions from MSW incinerators of various sizes against two illustrative criteria for acceptability: an “insignificant” release and a threshold above which the release may require further assessment for environmental effects and for control. Using the criteria developed in this paper, the current PCDD/F emission limit of 0.1 ng I-TEQ m−3results in an emission that is classed as “insignificant” for all plant sizes. However, higher emission concentrations can also be accommodated below the threshold for further assessment and control.  相似文献   

9.
Effects of carbon concentration and Cu additive in simulated fly ash (SFA) and real fly ash (RFA) on the formation of polychlorinated dibenzofurans (PCDFs), polychlorinated dibenzo-p-dioxins (PCDDs), chlorobenzenes, and polychlorinated biphenyls which were all regarded as persistent chlorinated aromatics in iron ore sintering were investigated. In the annealing process of SFA with various carbon contents, the yield of chlorinated aromatics and the I-TEQ obtained their maximum at 10 wt% carbon content. Active carbon in SFA acted as the carbon source as well as an adsorbent which led to higher production of PCDD/F in solid phase at 10 wt% carbon content. The increase of carbon content will be beneficial on the formation of 2,3,7,8-Chloro-substituted PCDF compared with 2,3,7,8-Chloro-substituted PCDD. In addition, the CuCl2·2H2O was a much more powerful catalyst in the formation of chlorinated aromatic compounds compared with elementary Cu, since it served as both a catalyst and a chlorine donor. However, the RFA behaved similarly with SFA with elementary Cu in the formation of chlorinated aromatic compounds. The effect of carbon content and copper additives on formation of 2,3,7,8-chloro-substituted congeners displayed similar characteristics with the tetra- to octa-PCDD/F isomers and even the total PCDD/Fs.  相似文献   

10.
Presence, sources and behaviour of polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were evaluated in Spanish sewage sludge. A total of 120 samples were seasonally collected from October 2005 to September 2006 at 31 urban wastewater treatment plants (WWTPs). Concentrations of PBDEs (ranging between 57.5 and 2606 ng/g dry weight) were two to three orders of magnitude higher than those obtained for PCDDs (0.17-5.03 ng/g d.w.) and PCDFs (0.05-3.07 ng/g d.w.). All the samples presented International Toxicity Equivalents (I-TEQ) levels (ranging between 2.06 and 44.4 ng/kg d.w.) below the limit values proposed by European Union for land application. Congener patterns evaluation revealed that the use of Deca-BDE commercial mixture seems to be the major source of PBDEs in the sludge. Nevertheless, origin of PCDD/Fs should be related to atmospheric deposition, faeces and presence of PCDD/Fs precursors such as pentachlorophenol in the sludge. No correlations (p > 0.05) were found between pollutant concentrations (PBDEs and PCDD/Fs) and wastewater treatment plant (WWTP) characteristics (capacity nor sludge rate). Lower levels of PBDEs and PCDFs were found in WWTPs using biological nitrogen and phosphorous elimination, suggesting that these compounds are susceptible of microbial elimination. According to our knowledge, this is the first work comparing together both PBDEs and PCDD/Fs sludge patterns.  相似文献   

11.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are formed during waste incineration and in waste-to-energy boilers. Incomplete combustion, too short residence times at low combustion temperatures (<700 °C), incineration of electronic waste and plastic waste containing chlorine are all factors influencing the formation of PCDD/Fs in boilers. The impact of chlorine and catalysing metals (such as copper and iron) in the fuel on PCDD/F formation was studied in a 12 MWth circulating fluidised bed (CFB) boiler. The PCDD/F concentrations in the raw gas after the convection pass of the boiler and in the fly ashes were compared. The fuel types were a so-called clean biomass with low content of chlorine, biomass with enhanced content of chlorine from supply of PVC, and solid recovered fuel (SRF) which is a waste fuel containing higher concentrations of both chlorine, and catalysing metals. The PCDD/F formation increased for the biomass with enhanced chlorine content and it was significantly reduced in the raw gas as well as in the fly ashes by injection of ammonium sulphate. A link, the alkali chloride track, is demonstrated between the level of alkali chlorides in the gas phase, the chlorine content in the deposits in the convection pass and finally the PCDD/F formation. The formation of PCDD/Fs was also significantly reduced during co-combustion of SRF with municipal sewage sludge (MSS) compared to when SRF was fired without MSS as additional fuel.  相似文献   

12.
Open dumping sites in Surabaya and Palembang, Indonesia, have been studied to investigate emissions of polychlorinated dibenzo-para-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (DL-PCBs), as well as the resulting soil contamination that might be caused by open burning of municipal solid waste. The emission factors of the waste residue, accounting for the ratio of waste burned, have also been characterized. The concentrations of PCDD/Fs and DL-PCBs in soil from Palembang were 61–310 pg-TEQ/g (dry weight) and 6.3–32 pg-TEQ/g, respectively. In Surabaya, very low levels of PCDD/Fs and DL-PCBs, ranging from 0.075 to 0.098 and 0.00032 to 0.095 pg-TEQ/g, respectively, were observed in soil for an open dumping site that included a top cover layer of soil above the compacted waste. The large difference in concentrations can be explained by the fact that open burning of waste is the source of PCDD/Fs and DL-PCBs. The emission factors for the residue for PCDD/Fs ranged from 27 to 140 pg-TEQ/g, and a sensitivity analysis found that the maximum emission factor to the residue could be 5600 pg-TEQ/g. Our results indicate that emissions of PCDD/Fs can be controlled by modifying the open dumping process to one that involves depositing soil layers on top of the compacted waste.  相似文献   

13.
The disposal, recycling, and part salvaging of discarded electronic devices such as computers, printers, televisions, and toys are now creating a new set of waste problems. This study is aimed at identifying the sources and quantifying the pollution levels generated from electronic waste (e-waste) activities at Guiyu, Guangdong Province, China, and their potential impacts on the environment and human health. The preliminary results indicate that total polycyclic aromatic hydrocarbons (PAHs) in soil obtained from a printer roller dump site was 593 μg/kg dry weight (dry wt.) and in sediment from a duck pond, the PAH concentration was 514 μg/kg (dry wt.). Sediment from the Lianjiang River was found to be contaminated by polychlorinated biphenyls (743 μg/kg) at a level approaching three times the Canadian Environmental Quality Guidelines probable effect level of 277 μg/kg. Total mono- to hepta-brominated diphenyl ether homologue concentrations (1140 and 1169 μg/kg dry wt.) in soils near dumping sites were approximately 10–60 times those reported for other polybrominated diphenyl ether-contaminated locations in the world. In-house study on the open burning of cable wires showed extremely high levels of polychlorinated dibenzo-p-dioxins and dibenzofurans resulting in 12419 ng toxic equivalents (TEQ)/kg of waste input and 15 610 ng TEQ/kg for two separate tests, respectively, which were about three orders of magnitude higher than those for the open burning of household waste. High levels of Cu (712, 528, and 496 mg/kg), exceeding the new Dutch list action value, were determined for soil near the printer roller dumping area, sediment from Lianjiang River, and soil from a plastic burn site, respectively. A more thorough study is underway to elucidate the extent of contamination of toxic pollutants in different ecological compartments to establish whether these pollutants are bioaccumulated and biomagnified through food chains. Assessments of human health impacts from oral intake, inhalation, and dermal contact will be subsequently investigated. An erratum to this article is available at.  相似文献   

14.
The input and output samples from existing large-scale municipal solid waste incinerator (MSWI) were collected and analyzed for polychlorinated dibenzo-р-dioxins and dibenzofurans (PCDD/Fs) in this study, aiming to evaluate PCDD/F characteristic and the corresponding mass balance through the whole system. The grate-type MSWI is equipped with semi-dry scrubber, activated carbon injection, and bag filter as air pollutant control devices (APCDs). Results showed that on the output side, the stack gas, bottom ash and fly ash presented their mean dioxin levels of 0.078 ng I-TEQ/Nm(3), 12.94 ng I-TEQ/kg and 858 ng I-TEQ/kg, respectively, and showed large similarities in congener profiles. Instead, on the input side, the municipal solid waste (MSW) presented a mean dioxin level of 15.56 ng I-TEQ/kg and a remarkable difference in congener profiles compared with those of the output. The dioxin mass balance demonstrated that the annual dioxin input value was around 5.38 g I-TEQ/yr, lower than the total output value (7.62 g I-TEQ/yr), signifying a positive dioxin balance of about 2.25 g I-TEQ/yr.  相似文献   

15.
To harmonize with international standards, the Republic of Korea is in the process of converting its current hazardous waste classification system and setting up regulatory standards for all toxic substances present in hazardous waste. Detailed characterization of each form of hazardous waste belonging to five chemical processes and their correlations were studied. In the present work, the concentrations of 13 heavy metals, F?, CN?, 7 PAH compounds, total PCDD/F and 7 PCB isomers present in the hazardous waste generated among chemical processes such as synthetic rubber (SR), man-made fibers (MF), organic dyes and pigments (DP), pharmaceuticals and cosmetics were analyzed along with their leaching characteristics. Comparing all the processes, most of the heavy metal concentrations were high in SR waste. Naphthalene was the dominant PAH in most of the chemical process waste. PCDD/F concentrations of the samples were in the range of 0.001–0.003 ng I-TEQ/g. PCB isomer-101 and isomer-118 were found to be slightly higher than the permissible limit in the SR filter cake sample. SR process wastes doesn’t show any resemblance with the other process waste in either the heavy metals and PAH trend. Each sample from DP and MF were suitable only for hazardous waste landfill.  相似文献   

16.
In order to comply with dioxin and furan (PCDD/F) emission regulations in Belgium, the IVRO municipal waste incinerator adopted catalytic filters for use in the plant's two existing fabric filters. This system replaced the injection of powdered activated carbon (PAC) because of concerns that PAC, used at temperatures above 200 degrees C, would ignite and lead to fires and plant down-time. The performance of the catalytic filter system, since its installation in 1997, is described. PCDD/F emissions are controlled to well below the regulatory limit of 0.1 ng I-TEQ/Nm3. The amount of PCDD/F entering and exiting the fabric filter is quantified. The resulting mass balance shows that greater than 99.5% of the gaseous PCDD/F entering the fabric filter is destroyed by the catalyst within the filter media.  相似文献   

17.
This paper gives the PCDD/F fingerprint of boiler and fly ash of a full scale hazardous waste incinerator and demonstrates that, when the waste to be incinerated contains high concentrations of PCBs and chlorinated pesticides, heterogeneous precursor condensation is the dominant PCDD/F formation mechanism rather than de novo synthesis. This is in contrast to full-scale municipal solid waste incinerators, where de novo synthesis has been shown to be the dominant PCDD/F formation mechanism. This paper agrees with earlier predictions based on numerous lab scale experiments.  相似文献   

18.
The application of activated carbons has become a commonly used emission control protocol for the removal or adsorption of persistent organic pollutants from the flue gas streams of waste incinerators. In this study, the 2378-substituted PCDD/F removal efficiency of three types of activated carbons derived from the pyrolysis of refuse derived fuel, textile waste and scrap tyre was investigated and compared with that of a commercial carbon. Experiments were carried out in a laboratory scale fixed-bed reactor under a simulated flue gas at 275 °C with a reaction period of four days. The PCDD/F in the solid matrices and exhaust gas, were analyzed using gas chromatography coupled with a triple quadrupole mass spectrometer. In the absence of activated carbon adsorbent, there was a significant increase in the concentration of toxic PCDD/F produced in the reacted flyash, reaching up to 6.6 times higher than in the raw flyash. In addition, there was a substantial release of PCDD/F into the gas phase, which was found in the flue gas trapping system. By application of the different commercial, refuse derived fuel, textile and tyre activated carbons the total PCDD/F toxic equivalent removal efficiencies in the exhaust gas stream were 58%, 57%, 64% and 52%, respectively. In general, the removal of the PCDDs was much higher with an average of 85% compared to PCDFs at 41%. Analysis of the reacted activated carbons showed that there was some formation of PCDD/F, for instance, a total of 60.6 μg I-TEQ kg−1 toxic PCDD/F was formed in the refuse derived fuel activated carbon compared to 34 μg I-TEQ kg−1 in the commercial activated carbon. The activated carbons derived from the pyrolysis of waste, therefore, showed good potential as a control material for PCDD/F emissions in waste incinerator flue gases.  相似文献   

19.
The huge amount of medical waste (MW) has caused a tough challenge to environmental protection in China because of its serious infectious potential. At present, incineration is the most common technology for MW disposal. Unfortunately, the medical waste incinerator (MWI) is considered one of the major sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). This study was conducted to investigate the generation and the components of MW; the fingerprint of PCDD/Fs in MWI; and PCDD/F, polychlorinated biphenyl (PCB) and hexachlorobenzene concentrations in residue ash. The estimated annual production of MW was estimated to be 0.97 million tons in China in 2008; in addition, plastic and rubber accounted for 24.5% of MW contents. PCDD/F emissions from MWI could be divided into two main groups according their fingerprints, and the ratio of PCDFs/PCDDs was mostly over 1.5, with a mean value of 3.43. The toxic equivalent of PCDD/Fs was over 30 times that of the value of PCBs in the residue ash, and PCDD/F contents in fly ash accounted for approximately 67% of the total output of PCDD/Fs, which was in line with the UNEP default emission factors for MWI (class 3, 63.7%).  相似文献   

20.
Environmental and safety aspects of seasonal storage of baled municipal solid waste to be used as fuel for energy production (waste fuel), was investigated and experiments were carried out on burning of bales. The flammability, combustion processes and emissions were studied by simulating, in small-scale, potential effects of a possible fire in full-scale bale storage area. Despite the high water content and the high density of the bales, after setting fire, the bales burned well, even though no risk for self-ignition exists. The following parameters of the combustion product were measured continuously: O2, CO2, CO, SO2, NO, NO2, NOx, THC, smoke gas rate and the temperature of the smoke. Soot particles in the smoke were collected and analysed for Hg, Pb, Cd, As, Ni, Cr, Mn, Cu, Co, Sb and V concentrations. The analysis of the moisture content, concentrations of Hg, Cd, HCl, HF, HBr, NH3, polyaromatic hydrocarbons (PAH), chlorinated and brominated dioxins (PCDD/F and PBrDD/F, respectively) were carried out. It was found that the PCDD/F levels (TEQs) varied according to the system used: 12.53 ng (I-TEF-88)/Nm3; 14.09 ng (I-TEF-99)/Nm3; 13.86 ng (Eadons)/Nm3. The PAH concentration was 3.04 microg/Nm3. The contents of the metals in the smoke (with the exceptions of Pb and Cd with mean values of 1.74 and 0.36 mg/m3, respectively) were below the limit values established by the Swedish Ministry of Environment for emissions from incineration plants [Swedish Ministry of Environment, (2002:1060), F?rordning 2002:1060 om avfallsf?rbr?nning. Available from http://www.notisum.se/rnp/SLS/LAG/20021060.HTM]/EU-directive [(2000/76/EC), Directive 2000/76/EC, of the European Parliament and of the Council of 4 December 2000 on the Incineration of Waste. http://www.Scotland. gov.uk/library5/environment/iecda.pdf]. The HCl concentration was 10 times higher than the limit value (mean value of 99 mg/m3).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号