首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
分点进水A/O工艺处理低碳源生活污水的脱氮性能研究   总被引:2,自引:1,他引:1  
针对低C/N比污水脱氮的难点问题,在缺氧段不同点设置进水口,采用分点进水A/O工艺处理校园生活污水.考察了在污泥回流比为100%,硝化液回流比为200%,分流比为1∶1,缺氧池水力停留时间(HRT)分别为2、2.4和3 h情况下,分点进水A/O工艺的反硝化性能,并与传统的A/O工艺进行比较.结果表明,当缺氧池的水力停留...  相似文献   

2.
This paper describes results from a pilot study of a novel wastewater treatment technology, which incorporates nutrient removal and solids separation to a single step. The pseudoliquified activated sludge process pilot system was tested on grit removal effluent at flowrates of 29.4 to 54.7 m3/d, three different solid residence times (SRT) (15, 37, and 57 days), and over a temperature range of 12 to 28 degrees C. Despite wide fluctuations in the influent characteristics, the system performed reliably and consistently with respect to organics and total suspended solids (TSS) removals, achieving biochemical oxygen demand (BOD) and TSS reductions of > 96% and approximately 90%, respectively, with BOD5 and TSS concentrations as low as 3 mg/L. Although the system achieved average effluent ammonia concentrations of 2.7 to 3.2 mg/L, nitrification efficiency appeared to be hampered at low temperatures (< 15 degrees C). The system achieved tertiary effluent quality with denitrification efficiencies of 90 and 91% total nitrogen removal efficiency at a total hydraulic retention time of 4.8 hours and an SRT of 12 to 17 days. With ferric chloride addition, effluent phosphorous concentrations of 0.5 to 0.8 mg/L were achieved. Furthermore, because of operation at high biomass concentrations and relatively long biological SRTs, sludge yields were over 50% below typical values for activated sludge plants. The process was modeled using activated sludge model No. 2, as a two-stage system comprised an aerobic activated sludge system followed by an anoxic system. Model predictions for soluble BOD, ammonia, nitrates, and orthophosphates agreed well with experimental data.  相似文献   

3.
以养猪场废水作为研究对象,采用序列间歇式活性污泥法SBR,通过实验研究了供气量、pH、排泥量、原水稀释倍数、水力停留时间(HRT)对SBR出水水质的影响。结果表明,供气量为375 L/(min·m3)、pH为8.0,并添加排泥100 mL的操作,可使SBR处理效果明显提高,COD、磷和凯氏氮去除率最高分别可达96.37%、94.14%、99.38%。逐步降低进水稀释倍数有利于培养出处理高浓度有机养猪废水的活性污泥,可将平均COD、磷和凯氏氮含量高达9 161.24、33.41和1 502.77 mg/L的养猪废水处理至出水的490.11、5.35和17.84 mg/L。降低HRT对SBR去除率影响不大。  相似文献   

4.
The performance of an innovative membrane bioreactor (MBR) process using anoxic phosphorus uptake with nitrification and denitrification for the treatment of municipal wastewater with respect to operational performance and effluent quality is addressed in this paper. The system was operated at steady-state conditions with a synthetic acetate-based wastewater at a hydraulic retention time (HRT) of 12 hours and on degritted municipal wastewater at a total system HRT of 6 hours. The MBR system was able to achieve 99% biochemical oxygen demand (BOD), chemical oxygen demand (COD), and ammonia-nitrogen (NH4(+)-N); 98% total Kjeldahl nitrogen (TKN); and 97% phosphorus removal, producing effluent BOD, COD, NH4+-N, TKN, nitrate-nitrogen, nitrite-nitrogen, and phosphate-phosphorus of <3, 14, 0.2, 0.26, 5.8, 0.21, and <0.01 mg/L, respectively, at the 6-hour HRT. The comparison of the synthetic and municipal wastewater run is presented in this paper. Steady-state mass balance on municipal wastewater was performed to reveal some key features of the modified MBR system.  相似文献   

5.
王冰  韩松 《环境工程学报》2014,8(6):2456-2460
对四级三相式生物流化床分段进水工艺脱氮效能进行了研究。通过改变进水C/N比、水力停留时间(HRT)和污泥回流比,考察了系统的脱氮效能,并与流化床A/O工艺脱氮效能进行对比。出水氨氮均小于1 mg/L,去除率保持在97%以上,TN去除率最高可达90%,出水水质均能够保证达标。在相同水质和运行条件下,将四级三相式生物流化床分段进水工艺与流化床A/O工艺进行对比,前者从脱氮效能和节约能源方面均表现出较强的优势。四级三相式生物流化床分段进水工艺无需外加碳源和内回流系统,是一种低碳节能的污水脱氮新工艺。  相似文献   

6.
分段进水多级生物膜反应器脱氮效能影响因素研究   总被引:2,自引:1,他引:1  
采用分段进水多级生物膜反应器处理高氮低碳小城镇污水,考察负荷、溶解氧和温度对反应器脱氮效能的影响。实验结果表明:负荷、溶解氧和温度对反应器脱氮效能有显著影响。在水温为20~25℃,DO为5 mg/L,负荷为1 kgCOD/(m3.d),挂膜密度为30%,第1、3、6级分段进水,流量分配比为2∶2∶1的条件下,在反应器中可成功构建出高效同时硝化反硝化系统,出水COD、NH4+-N和TN浓度分别为33 mg/L、2.6 mg/L和29.4 mg/L,去除率分别为90.1%、96.0%和63.9%。当水温≤15℃时,硝化速率受温度的影响显著。  相似文献   

7.
Microbial activity in a combined UASB-activated sludge reactor system   总被引:1,自引:0,他引:1  
Huang JS  Wu CS  Chen CM 《Chemosphere》2005,61(7):1032-1041
A combined upflow anaerobic sludge bed-activated sludge (UASB-AS) reactor system with consistently wasting of excess biomass was used to treat suspended-solids pre-settled piggery wastewater (COD=2000 mg l(-1), total Kjeldahl nitrogen TKN=400 mg l(-1), suspended solids=250-400 mg l(-1)). Thus, the activity of nitrogen-related microbial groups in each individual bioreactor was investigated. When the granules retention time (GRT) of 20-50 d in the UASB reactor, the solids retention time (SRT) of 10-25 d in the AS reactor and the recycle-to-influent ratio (Re) of 1 were maintained, the combined system removed 95-97% of chemical oxygen demand (COD), 100% of TKN and 54-55% of total nitrogen (TN). Denitrification and methanogenesis occurred in the UASB reactor so that both biochemical processes contributed to most of the COD removal and, complete nitrification (most of the TKN removal) occurred in the AS reactor. Compact granules with good settling abilities developed in the UASB reactor, and rapid rates of granulation of break-up granules in the UASB reactor were confirmed by experiments. The activity of nitrifiers and denitrifiers (an=0.68-0.87; adn=0.55-0.70) and the calculated specific nitrification and denitrification rates (qn=0.26-0.47 mg NH4+ -N mg VSS(-1)d(-1); qdn=0.046-0.076 mg NOx- -N mg VSS(-1)d(-1)) significantly increased with decreasing SRT and GRT, respectively. Accordingly, the combined UASB-AS reactor system should be regarded a promising alternative for the removal of organic carbon and nitrogen from piggery wastewater.  相似文献   

8.
The photo-Fenton reaction effect on the biodegradability improvement of 100 mg/L solution of 2,4-dichlorophenol (DCP) has been investigated. Biochemical oxygen demand (BOD) at 5 and 21 days, BODn/ chemical oxygen demand (COD) and BODn/total organic carbon (TOC) ratios, average oxidation state, and inhibition on activated sludge were monitored. For 50 mg/L hydrogen peroxide and 10 mg/L iron(II) initial concentrations and 40 minutes of reaction time in the photo-Fenton process, the biodegradability of the pretreated solution, measured as BOD5/COD ratio, was improved from 0 for the original DCP solution up to 0.18 (BOD21/COD = 0.24). At that point, all DCP was eliminated from the solution. To study the effect of the pretreatment step, the biological oxidation of pretreated solutions was tested in two semicontinuous stirred tank reactors, one operated with activated sludge and one with biomass acclimated to phenol. Results showed that more than 80% TOC removal could be obtained by codigestion of the pretreated solution with municipal wastewater. Total organic carbon removals of approximately 60% were also obtained when the sole carbon source for the aerobic reactors was the pretreated solution. The hydraulic retention times used in the bioreactors were of the same order of magnitude as those used at domestic wastewater treatment plants (i.e., between 12 and 24 hours). Kinetic studies based on pseudo-first-order kinetics have also been carried out. Constants were found to be in range 0.67 to 1.7 L x g total volatiles suspended solids(-1) x h(-1).  相似文献   

9.
研究了序批式水解酸化 厌氧 好氧生物处理工艺对NF合成制药废水的处理。由于NF制药废水中含有大量有毒有机化合物 ,在生物处理过程中这些有毒物质会抑制活性污泥的活性 ,因此需经过适当稀释原水以达到处理单元可接受的毒性范围。采用BODTrack快速测定了不同原水稀释条件下活性污泥呼吸曲线第一段斜率的变化 ,结果表明 ,当原水稀释 2 0倍以上后 ,对活性污泥的活性没有明显的抑制。通过批量实验 ,优化了工艺的运行条件 ,并进行了小试的连续运行。采用本工艺可以达到NF制药废水COD的稳定高效去除 ,结果显示 ,COD的去除率可达 76 %。  相似文献   

10.
Four laboratory-scale biological nitrification units (influent total Kjeldahl nitrogen [TKN] = 1002 to 1062 mg/L) were operated at chemical oxygen demand (COD)/TKN ratios of approximately 0.5, 1.0,15, and 2.0 and at three different sludge ages of 30, 20, and 10 days to study the influence of COD/TKN, sludge age, COD loading, and TKN loading on nitrification and nitrifiers. Percent nitrification was found to increase with decreases in COD/TKN and increases in sludge age. The average nitrifier concentration increased from 460 mg/L at a COD/TKN of 2.22 and a sludge age of 10 days to 706 mg/L at a COD/TKN of 0.676 and a sludge age of 30 days. The nitrifier fraction was found to be higher at a lower COD/TKN and lower at a higher COD/TKN. The nitrifier fraction increased with the decrease in sludge age and COD loadings and the increase in TKN loadings. The effect of sludge age on the nitrifier fraction was amplified at a COD/ TKN of approximately 0.5 rather than at approximately 2.0. The nitrification rate (kilograms TKN oxidized per kilograms nitrifiers per day) was shown to be dependent on COD/TKN and sludge age. The activity performed by Nitrobacter was affected at all COD/TKN ratios studied as well as at a sludge age of 10 days. This was manifested by the accumulation of high levels of nitrite-nitrogen in the nitrified effluent. The presence of heterotrophs did not affect nitrification rates and the growth of nitrifiers, which were found to be beneficial. High sludge age and COD loadings resulted in a higher sludge volume index of more than 200 mL/g mixed liquor suspended solids. Microscopic examination showed filamentous structure of sludge under these conditions. It is concluded from the investigations that a sludge age of 30 days and a COD/TKN of approximately 1.0 are optimal to yield maximum nitrification and nitrifier growth rates for treating high-strength nitrogenous wastewater.  相似文献   

11.
The immobilized cell augmented activated sludge (ICAAS) system combines a cell immobilization technique and an offline enricher-reactor for the bioaugmentation of the activated sludge system to improve treatment performances. In this study, enhanced nitrogen removal using ICAAS was investigated. Laboratory-scale, offline, batch enricher-reactors were used to maintain nitrification and denitrification activities of coimmobilized nitrifiers and denitrifiers used to augment a laboratory-scale completely mixed activated sludge system (CMAS) treating synthetic wastewater. Cellulose triacetate was the media used to entrap nitrifiers and denitrifiers at a 2:1 mass ratio. The ICAAS augmented with the coimmobilized cells between 5 and 20% by volume gained 24 +/- 5% higher nitrogen removal than a control CMAS, which provided nitrogen removal of 28 +/- 7%. The ICAAS scheme is a viable alternative for upgrading existing activated sludge systems to gain better nitrogen removal. .  相似文献   

12.
实际污水与模拟污水活性污泥系统的特性差异   总被引:2,自引:0,他引:2  
实验中经常采用人工配置的模拟生活污水,为了研究其与实际生活污水活性污泥系统的特性差异,采用2个序批式间歇反应器(SBR)进行平行实验(厌氧、好氧方式运行),系统地考察了在进水主要组分和运行参数相同的情况下,不同原水对活性污泥系统脱氮、除磷、比好氧速率、污泥絮体形态和出水水质等方面的影响。结果表明,模拟污水系统的硝化活性强于实际污水系统,两者的平均硝化速率分别为7.43 mg NH4+-N/(L.h)和5.55 mg NH4+-N/(L.h)。在前置厌氧段,模拟污水系统的释磷量比实际污水系统高出36.45%。两者在后续好氧阶段都能够充分吸磷。模拟污水系统的平均比好氧速率(SOUR)高达64.54 mg O2/(g MLSS.h),而实际污水系统的则只有32.81 mg O2/(g MLSS.h)。模拟污水系统的污泥絮体疏松,粒径小,形状不规则,沉降性差,沉后出水平均悬浮物浓度(SS)为20 mg/L;而实际污水系统的污泥絮体则密实、粒径大,沉降性好,沉后水十分清澈,SS几乎检测不出。  相似文献   

13.
在缺氧/好氧工艺的不同回流比条件下,对处理效果特别是脱氮效果进行了研究。结果表明,混合液和污泥合并回流,当回流比从R=4到R=7时,均能获得良好的脱氮效果,TN去除率达到75.4%以上,出水TN〈10mg/L。而回流比的变化对BOD的去除效果影响较小。当BOD污泥负荷从0.096kg/(kg&#183;d)降低到0.063ks/(kg&#183;d)时,对TN和BOD的去除率影响都很小。  相似文献   

14.
Simultaneous nitrification-denitrification (SND) of municipal wastewater was investigated in a laboratory-scale membrane bioreactor (MBR) operated at two different hydraulic retention times (HRTs), 0.5 and 1 day, dissolved oxygen 3.0 to 0.5 mg/L, and solids retention time (SRT) between 28 and 120 days. The organic loading rate (OLR) (0.11 to 0.64 kg chemical oxygen demand [COD]/m3/d) and influent soluble COD (SCOD)/ total Kjeldahl nitrogen (TKN) ratio (5 to 19) were varied by the addition of glucose. The ammonia-nitrogen and TKN removals were over 97%, and total nitrogen removal was approximately 89% in the MBR. The maximum specific nitrification rates (98 mg N/d/g VSS) and specific denitrification rates (81 mg N/d/g VSS) occurred at an SCOD/TKN ratio of 9.1. The optimum conditions for maximum total nitrogen removal by SND in a single reactor MBR have been found to be low dissolved oxygen (< 0.6 mg/L) and high OLR (approximately 0.64 kg COD/m3/d) at an HRT of 0.5 day and SRT of approximately 85 days.  相似文献   

15.
考察冬季低温下沸石联合生物吸附再生工艺和改进式沸石联合生物吸附再生工艺对城市污水的脱氮效率,结果表明在HRT为3.5 h下,ZCS工艺出水氨氮为11.65 mg/L,总氮高于20 mg/L.而相同条件下MZCS工艺氨氮出水为5.45 mg/L,总氮去除率比原ZCS工艺提高了11%,均值为16.8 mg/L.通过聚合酶链式技术,变性梯度凝胶电泳和电镜扫描技术发现两工艺微生物多样性、丰度高于传统活性污泥法,兼具活性污泥法和生物膜法的微生物特性.  相似文献   

16.
以实际生活污水为处理对象,考察了传统进水/曝气和改良型分段进水的交替缺氧-好氧(A/O)2种运行模式对CAST工艺的快速启动及脱氮除磷性能稳定维持的影响。结果表明,传统进水/曝气运行模式下,系统达到最佳营养物去除性能所需启动时间30 d,稳定运行阶段TN平均去除80.66%,磷的去除率维持在66.30%左右;采用改良型交替运行模式,反应器达到稳定运行状态仅需18 d,系统稳定运行时TN平均去除81.36%,磷去除率稳定维持在90%以上,出水磷浓度在0.3 mg/L以下,出水水质达到国家污水综合排放标准一级A(GB8978-2002)。研究还发现,传统运行模式下,由低温引起的污泥沉降性能变差导致系统污泥严重流失,反应器几乎丧失污染物去除性能;而低温对交替运行模式下的反应器除磷性能几乎没有影响,总氮去除则因氨氮不完全硝化而大大降低。  相似文献   

17.
在2个相同的SBR中分别驯化普通污泥和耐盐污泥,研究两者在0%、0.9%、1.2%、1.5%和1.8%(W/V)的盐度(NaCl)下对生活污水脱氮性能的差异。SBR运行经过厌氧、好氧、缺氧3个阶段,HRT分别为1、6和1 h。研究结果表明:在每一级盐度下,耐盐污泥的脱氮性能都好于普通污泥。随着盐度的增大,耐盐污泥中氨氮...  相似文献   

18.
The need to improve on-site wastewater treatment processes is being realized as populations move into more environmentally sensitive regions and regulators adopt the total maximum daily load approach to watershed management. Under many conditions, septic systems do not provide adequate treatment; therefore, advanced systems are required. These systems must remove significant amounts of biochemical oxygen demand (BOD) and suspended solids, and substantially nitrify, denitrify, and remove phosphorus. Many existing advanced on-site wastewater systems effectively remove BOD, suspended solids, and ammonia, but few substantially denitrify and uptake phosphorus. The purpose of this research was to design and test modifications to an existing on-site wastewater treatment system to improve denitrification and phosphorus removal. The Nayadic (Consolidated Treatment Systems, Inc., Franklin, Ohio), an established, commercially available, extended-aeration, activated sludge process, was used to represent a typical existing system. Several modifications were considered based on a literature review, and the option with the best potential was tested. To improve denitrification, a supplemental treatment tank was installed before the Nayadic and a combination flow splitter, sump, and pump box with a recirculation system was installed after it. A recirculation pump returned a high proportion of the system effluent back to the supplemental treatment tank. Two supplemental treatment tank sizes, three flowrates, and three recirculation rates were tested. Actual wastewater was dosed as brief slugs to the system in accordance with a set schedule. Several ion-exchange resins housed in a contact column were tested on the effluent for their potential to remove phosphorus. Low effluent levels of five-day biochemical oxygen demand, suspended solids, and total nitrogen were achieved and substantial phosphorous removal was also achieved using a 3780-L supplemental treatment tank, a recirculation ratio of 5:1, and a fine-grain activated aluminum-oxide-exchange media. Good results were also obtained with an 1890-L supplemental treatment tank and a recirculation ratio of 3:1. The most significant benefit of the supplemental treatment tank, in combination with the recirculation system, appears to be the low nitrogen concentration dosed to the Nayadic. By reducing the nitrogen concentration and spreading out its mass over time during no-flow periods, the Nayadic's inherent low-level denitrifying capacity was more closely matched and effective treatment was achieved.  相似文献   

19.
利用摇动床生物膜反应器(简称摇动床)技术具有的容积负荷高与污泥产量低的优点,在普通活性污泥池的前部填充高性能丙烯酸树脂纤维(Biofringe)填料,研究了摇动床和活性污泥法组合技术处理高浓度有机废水的有效性。结果表明,该组合技术具有很强的有机物去除能力,当进水COD平均质量浓度由1500mg/L上升到2514mg/L时,出水COD的平均去除率基本保持在96%以上;整个运行阶段的出水COD浓度均满足《污水综合排放标准》(GB8978—1996)的二级标准;当进水NH4+-N浓度增加时,NH4+-N的去除率由99.7%降低到76.5%,但是在试验运行的整个阶段,摇动床和活性污泥法组合技术系统都表现出较强的硝化能力;活性污泥池中最高的混合液悬浮固体(MLSS)质量浓度为10625mg/L,最高MLSS约为普通活性污泥法的4倍;运行结束后的污泥产率为0.186,污泥产率仅为普通活性污泥法的50%左右。  相似文献   

20.
An upflow anaerobic sludge blanket (UASB)-anoxicaerobic system was used for treatment of tomato and bean processing wastewater. At various hydraulic retention times, ranging from 0.7 to 5 days, excellent removal of chemical oxygen demand (COD), biochemical oxygen demand (BOD), total suspended solids (TSS), ammonia-nitrogen (NH4-N), and total Kjeldahl nitrogen was achieved with final effluent BOD/TSS/NH4N concentrations of less than 15/15/1 mg/L. Biogas yield in the UASB reactor varied from 0.33 to 0.44 m3/kgCODremoved. The kinetics of anaerobic treatment were investigated. The yield coefficient was 0.03 gVSS/gCOD; maximum specific growth rate was 0.24 day(-1); Monod half velocity constant was 135 mgCOD/L; and specific substrate utilization rate was 3.25 gCOD/gVSS x d. Nitrification and denitrification kinetics were studied in batch experiments, and the rates were comparable with those in the continuous flow system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号