首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 421 毫秒
1.
ABSTRACT: To measure crop evapotranspiration, a large double tank, electronic weighting lysimeter system was designed and installed at the Shahid Bahonar University farm, Kerman, Iran. The system was installed in a 50 m2 underground building. It includes two tanks of 3.00 m in diameter and 1.75 m deep. The weighing mechanism for each tank is a set of three compression strain gage load cells, which are fixed on 1.20 m height column above the floor. According to the specification of the load cells, the maximum possible weighing error may be about 0.01 percent of total mass, which is equivalent to 0.28 mm of water, but the measured error was equal to 1 kg mass, which is equivalent to 0.14 mm of water. The load cell data from each tank and the on‐site environmental data (temperature, humidity, and wind velocity and direction) are automatically recorded and saved in a personal computer hard disk for further use and analysis.  相似文献   

2.
Nitrogen removal in laboratory model leachfields with organic-rich layers   总被引:1,自引:0,他引:1  
Septic system leachfields can release dissolved nitrogen in the form of nitrate into ground water, presenting a significant source of pollution. Low cost, passive modifications, which increase N removal in traditional leachfields, could substantially reduce the overall impact on ground water resources. Bench-scale laboratory models were constructed to evaluate the effect of placing an organic layer below the leachfield on total N removal. The organic layer provides a carbon source for denitrification. Column units representing septic leachfields were constructed with sawdust-native soil organic layers placed 0.45 m below the influent line and with thicknesses of 0.0, 0.3, 0.6, and 0.9 m. Using a synthetic septic tank effluent, NO(3)-N concentrations at 3.8 m below the influent line were consistently below 1 mg L(-1) during 10 months of operation compared with a NO(3)-N concentration of nearly 12 mg L(-1) in the control column. The average total N removal increased from 31% without the organic layer to 67% with the organic layer. Total N removal appeared limited by the extent of organic N oxidation and nitrification in the 0.45-m aerobic zone. Design modifications targeted at improving nitrification above the organic layer may further increase total N removal. Increased organic layer thicknesses from 0.3 m to 0.9 m did not significantly improve average total N removal, but caused a shift in residual nitrogen from organic N to ammonia N. Results indicate that addition of a layer of carbon source material at least 0.3 m thick below a standard leachfield substantially improves total N removal.  相似文献   

3.
中空纤维膜生物反应器处理炼厂浮选池出水试验研究   总被引:2,自引:0,他引:2  
研究设计的膜生物反应器处理炼厂浮选池出水,在每天进水容积负荷1.0 kg COD/m3,进水COD浓度600 mg/L,MLSS为900~5500 mg/L的条件下,无论活性污泥表现正常还是膨胀,过滤出水中COD均稳定地小于90 mg/L,处理效果好于目前炼油厂的合建式曝气池(容积负荷为0.5 kg COD/m3左右,出水COD100 mg/L左右)。试验运行期间,膜通量最高可达到42 L/m2·h。该工艺的技术关键是采用特殊流态来降低膜堵塞的膜生物反应器和优良质量的膜。  相似文献   

4.
The objective of this study was to investigate the influence of flow rate on transport and retention of bacteriophage tracers in a fractured shale saprolite, which is a highly weathered, fine-grained subsoil that retains much of the fabric of the parent bedrock. Synthetic ground water containing PRD-1, MS-2, and bromide was passed through a saturated column of undisturbed shale saprolite at rates ranging from 0.0075 to 0.96 m d '. First arrival of the bacteriophage tracers in effluent samples in each of the experiments occurred within 0.01 to 0.04 pore volumes (PV) of the start of injection, indicating that bacteriophage were advectively transported mainly through fractures or macropores. Bacteriophage transport velocities, based on first arrival in the effluent, were very similar to fracture flow velocities calculated using the cubic law for flow in a fractured material. For MS-2, maximum concentration and mass of tracer recovered both increased steadily as flow rate increased. For PRD-1, these values initially increased, but were nearly constant at flow rates above 0.039 m d(-1), indicating that approximately 50% of the observed losses were independent of flow rate. Evaluation of the data indicates that physical straining and electrostatic or hydrophobic attachment to fracture or macropore walls were the dominant retention processes. Inactivation and gravitational settling playing secondary roles, except at the slowest flow rates. The study suggests that microbial contamination from sources such as septic fields and sewage ponds may pose a threat to the quality of ground water and surface water in areas with saprolitic subsoils.  相似文献   

5.
In smaller wastewater treatment systems such as septic systems, there is an interest in the development of passive phosphorus (P) removal methods. This study tested fixed-bed filters containing ferric oxyhydroxide media for wastewater P removal in a laboratory column test and in a full-scale domestic septic system. In the column test, during 30 mo of dosing with domestic wastewater, reductive iron dissolution reactions delivered consistent moderate concentrations of Fe into solution (2.9 ± 1.6 mg L), and influent PO-P of 3.7 ± 1.0 mg L was attenuated to 0.09 + 0.04 mg L in the column effluent (98% removal). Phosphorus breakthrough at successive locations along the column indicated that in addition to sorption, mineral precipitation reactions probably also played an important role in the observed P attenuation. This was supported by electron microprobe analyses, which showed the presence of thick (20 μm) secondary Fe-rich coatings containing P on the primary ferric media grains. Assays of NaHCO-leachable and acid-extractable P on the column solids showed accumulation of up to 5.4 mg g acid-extractable P near the column inlet, but <5% of this amount was easily desorbable, further indicating P attenuation from processes other than sorption. Over 19 mo of operation, the domestic septic system also showed generally consistent increased Fe in the filter effluent (2.6 ± 1.7 mg L) and achieved 99% P removal to 0.03 ± 0.02 mg L when the effluent was subsequently oxidized in a sand filter. Ferric iron filters could be attractive options for P removal in smaller wastewater systems because of their passive nature.  相似文献   

6.
A sequentially combined carbon (SCC) source using methanol and acetic acid was investigated for biological nitrogen and phosphorus removal in a wastewater treatment process consisting of an anoxic zone, an oxic zone and a final settling tank. The anoxic zone was divided into two separate anoxic zones to feed methanol in the first anoxic zone and acetic acid in the second anoxic zone. Methanol and acetic acid, each as the sole carbon source, were also tested for comparison. The use of SCC was superior in nitrogen removal with all combined COD ratios of methanol/acetic acid tested, yielding 95.8-97% efficiency (less than 1 mg N/l in the final effluent). The highest phosphorus removal of above 92% (final effluent concentration of 0.12 mg P/l) was achieved when only acetic acid was used at a quantity equivalent to 50 mg COD/l. However, when SCC was used, the acetic acid dosage of 50 mg COD/l could be reduced down to 20 mg COD/l when 30 mg COD/l was replaced by methanol; this resulted in a final effluent phosphorus concentration of 0.6 mg P/l. Additional benefits of SCC included the excellent sludge settling properties compared to the use of methanol or acetic acid alone.  相似文献   

7.
Rural areas represent approximately 95% of the 14000 km(2) Alabama Black Belt, an area of widespread Vertisols dominated by clayey, smectitic, shrink-swell soils. These soils are unsuitable for conventional onsite wastewater treatment systems (OWTS) which are nevertheless widely used in this region. In order to provide an alternative wastewater dosing system, an experimental field moisture controlled subsurface drip irrigation (SDI) system was designed and installed as a field trial. The experimental system that integrates a seasonal cropping system was evaluated for two years on a 500-m(2) Houston clay site in west central Alabama from August 2006 to June 2008. The SDI system was designed to start hydraulic dosing only when field moisture was below field capacity. Hydraulic dosing rates fluctuated as expected with higher dosing rates during warm seasons with near zero or zero dosing rates during cold seasons. Lower hydraulic dosing in winter creates the need for at least a two-month waste storage structure which is an insurmountable challenge for rural homeowners. An estimated 30% of dosed water percolated below 45-cm depth during the first summer which included a 30-year historic drought. This massive volume of percolation was presumably the result of preferential flow stimulated by dry weather clay soil cracking. Although water percolation is necessary for OWTS, this massive water percolation loss indicated that this experimental system is not able to effective control soil moisture within its monitoring zone as designed. Overall findings of this study indicated that soil moisture controlled SDI wastewater dosing is not suitable as a standalone system in these Vertisols. However, the experimental soil moisture control system functioned as designed, demonstrating that soil moisture controlled SDI wastewater dosing may find application as a supplement to other wastewater disposal methods that can function during cold seasons.  相似文献   

8.
In Ireland, no database detailing the design, influent loading rates or performance of constructed wetlands (CWs) exists. On account of this, they are designed without any protocol based on empirical data. The aim of this paper was to provide the first published data on the performance of free-water surface flow (FWSF) CWs treating primary and secondary-treated municipal wastewater, and agricultural dairy soiled water (DSW) in Ireland. In total, the performance of thirty-four FWSF CWs, comprising fourteen CWs treating primary-treated municipal wastewater, thirteen CWs treating secondary-treated municipal wastewater, and seven CWs treating DSW, were examined. In most CWs, good organic, suspended solids (SS) and nutrient removal was measured. At an average organic loading rate (OLR) of 10 and 9 g biochemical oxygen demand (BOD) m(-2) d(-1), CWs treating primary and secondary wastewater removed 95 and 84% of influent BOD. Constructed wetlands treating DSW had an average BOD removal of 98%. At average SS loading rates of 6 and 14 g m(-2) d(-1), CWs treating primary and secondary wastewater had a 96 and an 82% reduction, and produced a final effluent with a concentration of 14 and 13 mg L(-1). Constructed wetlands treating DSW produced a final effluent of 34 mg L(-1) (94% reduction). Similar to other studies, all CWs examined had variable performance in ammonium-N (NH(4)(+)-N) removal, with average removals varying between 37% (for CWs treating secondary wastewater) and 88% (for CWs treating DSW). Variable ortho-phosphorus (PO(4)(3-)-P) removal was attributable to different durations of operation, media types and loading rates.  相似文献   

9.
Nitrate in water removed from fields by subsurface drain ('tile') systems is often at concentrations exceeding the 10 mg N L(-1) maximum contaminant level (MCL) set by the USEPA for drinking water and has been implicated in contributing to the hypoxia problem within the northern Gulf of Mexico. Because previous research shows that N fertilizer management alone is not sufficient for reducing NO(3) concentrations in subsurface drainage below the MCL, additional approaches are needed. In this field study, we compared the NO(3) losses in tile drainage from a conventional drainage system (CN) consisting of a free-flowing pipe installed 1.2 m below the soil surface to losses in tile drainage from two alternative drainage designs. The alternative treatments were a deep tile (DT), where the tile drain was installed 0.6 m deeper than the conventional tile depth, but with the outlet maintained at 1.2 m, and a denitrification wall (DW), where trenches excavated parallel to the tile and filled with woodchips serve as additional carbon sources to increase denitrification. Four replicate 30.5- by 42.7-m field plots were installed for each treatment in 1999 and a corn-soybean rotation initiated in 2000. Over 5 yr (2001-2005) the tile flow from the DW treatment had annual average NO(3) concentrations significantly lower than the CN treatment (8.8 vs. 22.1 mg N L(-1)). This represented an annual reduction in NO(3) mass loss of 29 kg N ha(-1) or a 55% reduction in nitrate mass lost in tile drainage for the DW treatment. The DT treatment did not consistently lower NO(3) concentrations, nor reduce the annual NO(3) mass loss in drainage. The DT treatment did exhibit lower NO(3) concentrations in tile drainage than the CN treatment during late summer when tile flow rates were minimal. There was no difference in crop yields for any of the treatments. Thus, denitrification walls are able to substantially reduce NO(3) concentrations in tile drainage for at least 5 yr.  相似文献   

10.
以奇台太极华力食品有限公司番茄废水处理工程实例为依据,介绍了采用ABR厌氧+完全混合活性污泥法工艺在处理番茄加工废水的设计、调试及运行情况。经过2年运行,其进水COD在700~1 500mg/L之间,最大处理水量达到4 000m3/d;出水COD在40~70mg/L之间,COD去除率达到97%。处理出水可以稳定达到污水综合排放二级标准。ABR+完全混合活性污泥法工艺具有启动快,调试时间短,工程造价低的优点,尤其适宜处理番茄等间歇时间长工作时间短的季节性生产污水。  相似文献   

11.
Land treatment of municipal wastewater effluent is a proven method for augmenting freshwater resources and avoiding direct nutrient discharges to surface waters. We assessed changes in soil test phosphorus (P) of the Ap horizon of cropped fields continuously irrigated for 26 yr with secondary effluent from the Penn State University wastewater treatment plant. For annual P additions averaging 97 kg P ha(-1), Mehlich-3 P (M3P) response in the 0- to 20-cm surface soil (initially < 20 mg kg(-1)) was represented by two lines. For the first 12 yr of irrigation, soil test P increased, with 14.5 kg P ha(-1) needed to increase M3P by 1 mg P kg(-1). After the initial buildup, M3P maintained a quasi-steady-state value of approximately 110 mg kg(-1). Over time, the surface soil equilibrium P concentration at zero sorption increased markedly (from < 1 to 5.5 mg P L(-1)), and extractable aluminum (Al) decreased significantly (P < 0.001). Speciation modeling using Visual MINTEQ suggests complexation of Al by dissolved organic carbon at site pH conditions. Loss of Al from the surface layer lowered its P-sorbing capacity, causing added effluent-P to move into the subsoil. Results suggest that current management practices can continue for many years without exceeding the surface soil M3P environmental threshold (200 mg kg(-1)) used in state P-based nutrient policies.  相似文献   

12.
The operational parameter MRT%FE, representing the mean residence time of different ages fractions of effluent within a completely mixed reactor, was evaluated and integrated with first order kinetics. The parameter was used to model Escherichia coli concentrations in a municipal wastewater reservoir managed under different operating conditions (continuous and discontinuous). The study was conducted during 2004-2005 in a reservoir receiving effluents from the activated sludge treatment plant of Caltagirone (Eastern Sicily - Italy). The analytical approach is applied to the hydraulic state variables of the system (daily stored volumes, inlet and outlet flows), and the physical-chemical (pH, temperature, EC, TSS, BOD(5), COD) and bacteriological wastewater parameters (E. coli, FC, FS). In order to evaluate the reliability of the proposed approach, predicted E. coli concentrations within the reservoir were compared with measured ones by the correlation coefficient, F-test and Sperman's index. The study included the evaluation of die-off coefficient K(T) (d(-1)), light extinction coefficient K (m(-1)) and their relationships with climatic factors. Results of the study confirm that E. coli removal is related to the fractions of fresh effluent remaining each day within the reservoir with MRT%FE of about 5-8d, significantly lower than the nominal detention time (about 27d). The E. coli die-off coefficient (K(T)) was higher during system discontinuous operations and correlated with incident solar radiation and water temperature.  相似文献   

13.
We studied the long-term in situ accumulation of Cu, Cr, Ni, and Zn in the soil profile of a large-scale effluent recharge basin after 24 yr of operation in a wastewater reclamation plant using the Soil Aquifer System approach in the Coastal Plain of Israel. The objective was to quantify metals accumulation in the basin's soil profile, clarify retention mechanisms, and calculate material balances and metal removal efficiency as the metal loads increase. Effluent recharge led to measurable accumulation, relative to the pristine soil, of Ni and Zn in the 0- to 4-m soil profile, with concentration increases of 0.3 to 1.3 mg kg(-1) and 2.9 to 6.4 mg kg(-1), respectively. Copper accumulated only in the 0- to 1-m top soil layer, with concentration increase of 0.28 to 0.76 mg kg(-1). Chromium concentration increased by 3.1 to 7.3 mg kg(-1) in the 0- to 1-m horizon and 0.9 to 2.3 mg kg(-1) at deeper horizons. Sequential selective extraction showed Cu tended to be preferentially retained by Fe oxides and organic matter (OM), Cr by OM, Ni by OM, and carbonate and Zn by carbonate. The average total retained amounts of Cu, Cr, Ni, and Zn were 0.7 +/- 1.0, 13.6 +/- 4.8, 4.3 +/- 3.6, and 28.7 +/- 5.4 g per a representative unit soil slab (1 m(2) x 4 m) of the basin, respectively. This amounts to 3.6 +/- 4.9%, 79.5 +/- 28.0%, 8.0 +/- 6.9%, and 9.3 +/- 1.8% of the Cu, Cr, Ni, and Zn loads, respectively, applied during 24 yr of effluent recharge (total of approximately 1880 m effluent load). The low long-term overall removal efficiency of the metals from the recharged effluent in the top horizon may be due to the metals' low concentrations in the recharged effluent and the low adsorption affinity and retention capacity of the sandy soil toward them. This leads to attainment of a quasi-equilibrium and a steady state in element distribution between the recharged effluent solution and the soil after few years of recharge and relatively small cumulative effluent loadings.  相似文献   

14.
Recently, our attention has focused on the low level detection of many antibiotics, pharmaceuticals, and other organic chemicals in water resources. The limited studies available suggest that urban or rural streams receiving wastewater effluent are more susceptible to contamination. The purpose of this study was to evaluate the occurrence of antibiotics, pharmaceuticals, and other organic chemicals at 18 sites on seven selected streams in Arkansas, USA, during March, April, and August 2004. Water samples were collected upstream and downstream from the influence of effluent discharges in northwestern Arkansas and at one site on a relatively undeveloped stream in north-central Arkansas. At least one antibiotic, pharmaceutical, or other organic chemical was detected at all sites, except at Spavinaw Creek near Mayesville, Arkansas. The greatest number of detections was observed at Mud Creek downstream from an effluent discharge, including 31 pharmaceuticals and other organic chemicals. The detection of these chemicals occurred in higher frequency at sites downstream from effluent discharges compared to those sites upstream from effluent discharges; total chemical concentration was also greater downstream. Wastewater effluent discharge increased the concentrations of detergent metabolites, fire retardants, fragrances and flavors, and steroids in these streams. Antibiotics and associated degradation products were only found at two streams downstream from effluent discharges. Overall, 42 of the 108 chemicals targeted in this study were found in water samples from at least one site, and the most frequently detected organic chemicals included caffeine, phenol, para-cresol, and acetyl hexamethyl tetrahydro naphthalene (AHTN).  相似文献   

15.
Co-disposal of septic tank sludge had a positive effect on the municipal solid waste (MSW) stabilisation process in Bioreactor Landfill simulators. Co-disposal experiments were carried out using the Bioreactor Landfill approach aiming to solve the environmental problems caused by indiscriminate and inadequate disposal of MSW and especially of septic tank sludge. The simulator receiving septic tank sludge exhibited a 200 days shorter lag-phase as compared to the 350 days required by the control simulator to start the exponential biogas production. Additionally, the simulator with septic sludge apparently retained more moisture (>60% w/w), which enhanced the overall conversion of organic matter hence increasing the biogas production (0.60 m3 biogas kg(-1)VS(converted)) and removal efficiency of 60% for VS from the simulator. Alkaline pH values (pH>8.5) did not inhibit the biogas production; moreover it contributed to reduce partially the negative effects of NH(4)(+) (>2 g L(-1)) due to NH(3) volatilisation thus reducing the nitrogen content of the residues. Associated risks and hazards with septage disposal were practically eliminated as total coliform and faecal coliform contents were reduced by 99% and 100%, respectively at the end of the experiment. These results indicate that co-disposal has two direct benefits, including the safe and environmentally sound disposal of septic tank sludge and an improvement of the overall performance of the Bioreactor Landfill by increasing moisture retention and supplying a more acclimatised bacterial population.  相似文献   

16.
李剑波 《四川环境》2011,30(2):83-87
二沉池的运行状况对整个污水处理系统的处理效果有重要影响。沉淀池的处理效果与沉淀池内水流特性密切相关。传统的沉淀池设计基于理想沉淀池假设和静置沉淀实验,对沉淀池内的水流特性考虑不多,设计参数选择范围宽,经验性强,不能保证沉淀池内的泥水分离和浓缩效果。计算流体力学是一种较为成熟的数值模拟技术,已广泛应用于水处理构筑物在设计条件下的内部水流特性和行为的研究,为预测沉淀池的运行状况和结构改进的效果提供了有效手段。本文对沉淀池内的水流特性和流体力学在沉淀池研究中的应用进行了描述。  相似文献   

17.
Properly functioning on-site wastewater systems (OWS) are an integral component of the wastewater system infrastructure necessary to renovate wastewater before it reaches surface or ground waters. There are a large number of factors, including soil hydraulic properties, effluent quality and dispersal, and system design, that affect OWS function. The ability to evaluate these factors using a simulation model would improve the capability to determine the impact of wastewater application on the subsurface soil environment. An existing subsurface drip irrigation system (SDIS) dosed with sequential batch reactor effluent (SBRE) was used in this study. This system has the potential to solve soil and site problems that limit OWS and to reduce the potential for environmental degradation. Soil water potentials (Psi(s)) and nitrate (NO(3)) migration were simulated at 55- and 120-cm depths within and downslope of the SDIS using a two-dimensional code in HYDRUS-3D. Results show that the average measured Psi(s) were -121 and -319 cm, whereas simulated values were -121 and -322 cm at 55- and 120-cm depths, respectively, indicating unsaturated conditions. Average measured NO(3) concentrations were 0.248 and 0.176 mmol N L(-1), whereas simulated values were 0.237 and 0.152 mmol N L(-1) at 55- and 120-cm depths, respectively. Observed unsaturated conditions decreased the potential for NO(3) to migrate in more concentrated plumes away from the SDIS. The agreement (high R(2) values approximately 0.97) between the measured and simulated Psi(s) and NO(3) concentrations indicate that HYDRUS-3D adequately simulated SBRE flow and NO(3) transport through the soil domain under a range of environmental and effluent application conditions.  相似文献   

18.
Managing household wastewater is an issue that affects hundreds of thousands of people in rural communities nationwide, many of whom rely on septic systems as their primary means of household wastewater disposal. Septic system absorption field products with architectures quite different from traditional pipe-and-gravel systems are being installed in many states with variances from initial design specifications. The objective of this study was to evaluate the performance, as measured by the in-product height of stored solution, of four differing absorption-field product architecture types in a profile-limited soil that was loaded at the maximum allowable rate based on soil morphology. Five chamber, two gravel-less pipe, two polystyrene aggregate, and four pipe-and-gravel systems were installed in a profile-limited, Captina silt loam soil (fine-silty, siliceous, active, mesic Typic Fragiudult) and dosed with raw effluent at rates determined by current State of Arkansas regulations via individual peristaltic pumps. Free-solution monitoring ports were installed within each product, where the depth to free solution was measured periodically and used to evaluate product performance. Data collected from January through August 2009 indicated that preliminary system performance was unaffected by product architecture type. All products performed similarly under dry soil conditions. However, differences among individual products were observed during periods of hydrologic stress (i.e., wet soil conditions). Surfacing of effluent was not observed atop any product, indicating that the current loading rate design method is functioning properly. Preliminary results indicate that some alternative absorption-field products perform similarly to the traditional pipe-and-gravel system, thus providing flexibility and options for homeowners.  相似文献   

19.
Land application of wastewater presents potential for ground water pollution if not properly managed. In situ breakthrough tests were conducted using potato (Solanum tuberosum L.)-processing wastewater and a Br tracer to characterize P leaching in seasonally frozen sandy outwash soils. In the first test, P and Br breakthrough were measured in a 7-m deep well following wastewater [2.94 mg L(-1) total P (TP); 280 mg L(-1) Br] application at the site that had 13.1 mg water-extractable P (WEP) kg(-1)and 94.4 mg Bray-1 P kg(-1). Bromide was detected in the well after approximately 0.4 pore volumes, but there was no P break-through after 7 pore volumes. In the second breakthrough test, wastewater containing 3.6 mg L(-1) TP and 259 mg L(-1) Br was applied on 1.5-m deep lysimeters at low (0.8 mg WEP kg(-1); 12.1 mg Bray-1 P kg(-1)) and high soil test P sites (104 mg WEP kg(-1); 585 mg Bray-1 P kg(-1)). Leachate TP concentration during the test remained constant (0.04 mg L(-1)) at the low P sites but increased from approximately 3.5 to 5.6 mg L(-1) at the high P sites. These results indicate no P leaching in low P soils, but leaching in high P soils, thus suggesting that most of the P leached at the high P sites was mainly due to desorption and dissolution of weakly adsorbed P from prior P applications. This was consistent with P transport simulations using the convective-dispersive equation. We conclude that P concentration in land-applied wastewater should be regulated based on soil test-P level plus wastewater P loading.  相似文献   

20.
Toxic metals removal from wastewater sewage sludge can be achieved through microbial processes involving Acidithiobacillus ferrooxidans. The oxidation of ferrous ions by A. ferrooxidans, cultured in sewage sludge filtrate, was studied in both batch and continuous flow stirred tank reactors. Sewage sludge filtrate containing natural nutrients (phosphorus and nitrogen) was recovered as effluent following the dehydration of a primary and secondary sludge mixture. Batch and continuous flow stirred tank reactor tests demonstrated that A. ferrooxidans were able to grow and completely oxidize ferrous iron in a culture medium containing more than 80% (v v(-1)) sewage sludge filtrate with 10 g Fe(II) L(-1) added. Toxic levels were reached when total organic carbon in the sewage sludge filtrate exceeded 250 mg L(-1). The ferric iron solution produced in the sludge filtrate by A. ferrooxidans was used to solubilize heavy metals in primary and secondary sludge. The solubilization of Cu, Cr, and Zn yielded 71, 49, and 80%, respectively. This is comparable with the yield percentages obtained using a FeCl(3) solution. The cost of treating wastewater sewage sludge by bioproducing a ferric ion solution from sewage sludge is three times less expensive than the conventional method requiring a commercial ferric chloride solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号