首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Chung YC  Huang C  Tseng CP  Pan JR 《Chemosphere》2000,41(3):329-336
Gas mixture of H2S and NH3 in this study has been the focus in the research area concerning gases generated from the animal husbandry and the anaerobic wastewater lagoons used for their treatment. A specific microflora (mixture of Thiobacillus thioparus CH11 for H2S and Nitrosomonas europaea for NH3) was immobilized with Ca-alginate and packed inside a glass column to decompose H2S and NH3. The biofilter packed with co-immobilized cells was continuously supplied with H2S and NH3 gas mixtures of various ratios, and the removal efficiency, removal kinetics, and pressure drop in the biofilter was monitored. The results showed that the efficiency remained above 95% regardless of the ratios of H2S and NH3 used. The NH3 concentration has little effect on H2S removal efficiency, however, both high NH3 and H2S concentrations significantly suppress the NH3 removal. Through product analysis, we found that controlling the inlet ratio of the H2S/NH3 could prevent the biofilter from acidification, and, therefore, enhance the operational stability. Conclusions from bioaerosol analysis and pressure drop in the biofilter suggest that the immobilized cell technique creates less environmental impact and improves pure culture operational stability. The criteria for the biofilter operation to meet the current H2S and NH3 emission standards were also established. To reach Taiwan's current ambient air standards of H2S and NH3 (0.1 and 1 ppm, respectively), the maximum inlet concentrations should not exceed 58 ppm for H2S and 164 ppm for NH3, and the residence time be kept at 72 s.  相似文献   

2.
Hydrogen sulfide (H2S) is one of the most toxic and offensively odorous gases and is generated in anaerobic bioreactors. A middle-thermophilic sulfur-oxidizing bacterium (SOB), Thiomonas sp. strain RAN5, was isolated and applied for H2S removal from both artificial and anaerobically digested gas. When a bioreactor containing medium inoculated with RAN5 was aerated continuously with artificial gas (containing 100 ppm H2S) at 45 degrees C for 156 hr, the H2S concentration in the vented gas was reduced by 99%. This was not affected by the presence of other microbes in the bioreactor The H2S removal efficiency of the RAN5 bioreactor for anaerobically digested gas was greater than 99% at influent H2S concentrations ranging from 2 to 1800 ppm; the efficiency decreased to 90% at influent H2S concentrations greater than 2000 ppm. Thiomonas sp. strain RAN5 cannot survive at room temperature, and thus its leakage from a wastewater treatment plant would not damage sewage systems. These data suggest that Thiomonas sp. strain RAN5 may be a useful microorganism for H2S removal.  相似文献   

3.
Long-term operation of a biofilter for simultaneous removal of H2S and NH3   总被引:5,自引:0,他引:5  
Simultaneous removal of NH3 and H2S was investigated using two types of biofilters--one packed with wood chips and the other with granular activated carbon (GAC). Experimental tests and measurements included analyses of removal efficiency (RE), metabolic products, and results of long-term operation (around 240 days). The REs for NH3 and H2S were 92 and 99.9%, respectively, before deactivation. After deactivation, the RE for NH3 and H2S were decreased to 30-50% and 75%, respectively. The activity of nitrifying bacteria was inhibited by high concentrations of H2S (over 200 ppm) but recovered gradually after H2S addition was ceased. However, the Thiobacillus thioparus as sulfur oxidizing bacteria did not show inhibition at the NH3 concentration under 150-ppm conditions. The deactivation of the biofilter was caused by metabolic products [elemental sulfur and (NH4)2SO4] accumulating on the packing materials during the extended operation. The removal capacities for NH3 and H2S were 6.0-8.0 and 45-75 mg N, S/L/hr, respectively.  相似文献   

4.
复合式生物除臭反应器处理城市污水处理厂恶臭气体   总被引:4,自引:0,他引:4  
采用复合式生物除臭反应器处理北京某城市污水处理厂污泥浓缩池和脱水间散发的恶臭气体,研究了反应器对恶臭气体的净化效果和微生物悬浮生长区与附着生长区内的生物特性及对恶臭污染物的去除能力。该污水处理厂的恶臭气体中主要发臭物质为硫化氢和氨,除臭反应器的运行结果表明,在设备稳定运行期间,进气中硫化氢和氨的浓度分别为0.21~22.61 mg/m3和0.1~0.5 mg/m3,而出气中硫化氢浓度在0~0.06 mg/m3,氨浓度为0~0.02 mg/m3。对反应器内部测试表明,微生物悬浮生长区和附着生长区对硫化氢和氨都有一定的去除,但去除机理不同。硫化氢主要被附着生长区的嗜酸性硫细菌生物氧化,少量硫化氢在悬浮区溶于水被中性硫细菌氧化;氨主要在悬浮区靠生物硝化作用去除,少部分氨在附着区被去除,且多因化学中和作用转移到填料所含的水中。  相似文献   

5.
以氧化节杆菌为吸附剂,处理Cu(NO3)2、CuSO4和CuCl2溶液,研究菌体对Cu2+和NO3-的吸附效果,以及NO 3-、SO42-和Cl-对Cu2+吸附的影响。结果表明氧化节杆菌对Cu2+和NO 3-的吸附具有选择性。Cu2+的吸附效果理想,0.1 g/L菌体在10 min时,对2 mg/L Cu2+的吸附率达...  相似文献   

6.
In this study, biofiltration using a natural wood chip medium and a commercial biofiltration medium was evaluated for the removal of moderate concentrations of hydrogen sulfide (H2S) (up to 100 parts per million by volume [ppmv]) in the presence of significant concentrations of ammonia (NH3). These levels were chosen as representative of wastewater lift station emissions in the Brownsville, TX, area. NH3-removing portions of the biofilms may compete with H2S-removing portions and inhibit H2S removal. H2S process removal efficiencies for the commercial and natural media ranged from 90 to 96% depending on inlet loading and media type and bed height. Kinetic analysis of the H2S removal process followed apparent first-order reaction behavior. The average first-order reaction rates were 0.03 sec(-1) for the commercial medium and 0.09 sec(-1) for the natural medium. Pressure drops across the columns ranged from 0.41 in. H2O/ft for the commercial medium to 1.41 in. H2O/ft for the natural medium. NH3 gas levels of up to 80 ppmv did not affect the H2S removal process efficiency, and calculated kinetic rate constants for H2S removal remained almost the same. The NH3 gas also was removed simultaneously with the H2S up to 98% removal efficiency by the commercial medium.  相似文献   

7.
Ground-level O3 formation is becoming a major concern in many cities due to recent tightening of O3 regulations. To control O3 formation, more efficient treatment processes for O3 precursors, such as NOx and volatile organic compounds (VOCs), are needed. One promising new technology for removing both NOx and VOCs from off-gas streams is biofiltration, a simple process whereby contaminated air is passed through a biologically active packed bed. In this study, a toluene-degrading fungal bioreactor was used to treat an aerobic gas stream contaminated with NO. The fungal bioreactor removed 93% of the inlet 250-ppmv NO at an empty bed contact time (EBCT) of 1 min when supplied with 90 g/m3/hr toluene. The presence of NH4+ concentrations greater than 0.4 mg NH3/g dry packing medium, however, resulted in poor NO removal. The bioreactor achieved a maximum toluene elimination capacity of 270 g/m3/hr and maintained greater than 95% toluene removal efficiencies over the 175-day study period.  相似文献   

8.
Simultaneous removal of hydrogen sulfide (H2S) and ammonia (NH3) gases from gaseous streams was studied in a biofilter packed with granule activated carbon. Extensive studies, including the effects of carbon (C) source on the growth of inoculated microorganisms and gas removal efficiency, product analysis, bioaerosol emission, pressure drop, and cost evaluation, were conducted. The results indicated that molasses was a potential C source for inoculated cell growth that resulted in removal efficiencies of 99.5% for H2S and 99.2% for NH3. Microbial community observation by scanning electron microscopy indicated that granule activated carbon was an excellent support for microorganism attachment for long-term waste gas treatment. No disintegration or breakdown of biofilm was found when the system was operated for 140 days. The low bioaerosol concentration emitted from the biofilter showed that the system effectively avoided the environmental risk of bioaerosol emission. Also, the system is suitable to apply in the field because of its low pressure drop and treatment cost. Because NH3 gas was mainly converted to organic nitrogen, and H2S gas was converted to elemental sulfur, no acidification or alkalinity phenomena were found because of the metabolite products. Thus, the results of this study demonstrate that the biofilter is a feasible bioreactor in the removal of waste gases.  相似文献   

9.
Low-concentration acidic and basic-waste gas pollutants contribute significantly in the total emission of a facility. Previous results show that the control of high volumetric flow rate (approximately 500 m3/min), low-concentration acidic (< 1 ppm by vol) and basic (< 3 ppm by vol) gases from semiconductor process vent, by conventional wet scrubbing technique is a challenging task. This work was targeted to enhance the performance of packed beds for high-volumetric flow rate, low-concentration acidic (HF, HCl), and basic (NH3)-waste gases from the semiconductor manufacturing process. The methodology used to meet the goal was the application of fine-water mist over the inlet stream before entering to the packed bed and use of the surfactant with mist/packed-bed liquid in low concentration. An experimental study was carried out in two acid-packed beds to optimize the operating conditions, such as pH of the liquid, circulating liquid flow rate, blow-down cycle, and so forth. The relationship among liquid pH, liquid ionic concentration, and the removal efficiency of the packed bed for the pollutants has been discussed considering chemical equilibrium, two-film theory, and Henry's law. For the potential utilization of scrubbing water, the dependency of the efficiency on blow-down cycle was studied, and a mechanism is suggested. The proposed water-mist surfactant system was installed in two acid-packed beds, and performance of the packed beds was compared. The background efficiencies of the acid-packed beds for HF, HCl, and NH3 were found max to be (n = 11) 53, 40, and 27%, whereas after installation of the system, they increased significantly and became 76 +/- 13% (n = 10), 76 +/- 8% (n = 7), and 78 +/- 7% (n = 7), respectively, for inlet concentrations of HF and HCl < 1 ppm and NH3 < 14 ppm. The mechanism by which the surfactants operate to enhance the removal in scrubbing process is suggested considering the hydrodynamic effect and the interfacial effect with the charge-generating characteristic of surfactants on water surface, when dissolved into water. The results show that a proposed rectification system can effectively reduce the emission rates below the regulatory level (0.6 kg/hr) at the present conditions of the facility.  相似文献   

10.
扩体错流式生物滴滤床净化甲苯废气   总被引:1,自引:1,他引:0  
采用自行设计制作的扩体错流式生物滴滤床,以甲苯为目标污染物、陶粒为填料、恶臭假单胞菌为菌源进行实验,研究了扩体错流式生物滴滤床的挂膜启动情况、甲苯进口浓度、停留时间对净化效率的影响.结果表明:(1)环境温度为17~23℃,扩体错流式生物滴滤床在10 d内完成挂膜启动,比传统生物滴滤床缩短了4 d.(2)甲苯净化效率随进口浓度的增加而逐渐下降.当甲苯进口质量浓度为1 100 mg/m~3时,净化效率为95%;当甲苯进口质量浓度维持在1 100~1 200 mg/m~3时,随停留时间的缩短,甲苯净化效率下降.(3)当停留时间分别为94、63、48 s时,甲苯净化效率分别为87%~92%、70%~74%、60%~62%.  相似文献   

11.
用低浓度SO2诱导驯化方法获得高效脱硫菌群,并用分离培养与16S rRNA基因测序技术相结合的方法鉴定菌群种属,分析驯化过程中种群结构的动态变化,同时研究分离纯菌种的脱硫性能。结果表明,从诱导驯化7 d和14 d菌液中分别分离出23株菌和22株菌,16S rRNA序列分析发现这些菌归属于13个种,其中有6个种(Rhodococcus erythropolis、Pseudomonas putida、Microbacterium oxydans、Sphingomonas koreensis、Acinetobacter junii、Acinetobacter johnsonii)对SO2-3有较强的降解能力,并在持续驯化过程中稳定的生长传代,降解产物以硫酸根为主,还有极少量的单质硫。与含混合菌的驯化菌液降解SO2-3的能力相比,单一脱硫菌的脱硫性能较弱。脱硫功能菌株及其基本特性的研究为微生物处理SO2烟气提供了丰富的菌源信息和理论基础。  相似文献   

12.
Controlled bench-scale laboratory experiments were conducted to evaluate the recovery of ammonia (NH3) and hydrogen sulfide (H2S) from dynamic isolation flux chambers. H2S (80-4000 ppb) and NH3 (5000-40,000 ppb) samples were diffused through the flux chamber to simulate ground level area source emissions while measuring the inlet and outlet flux chamber concentrations simultaneously. Results showed that the recovery of H2S during a 30-min sampling time was almost complete for concentrations >2000 ppb. At the lowest concentration of 80 ppb, 92.55% of the H2S could be recovered during the given sampling period. NH3 emissions exhibited similar behavior between concentrations of 5000-40,000 ppb. Within the 30-min sampling period, 92.62% of the 5000-ppb NH3 sample could be recovered. Complete recovery was achieved for concentrations >40,000 ppb. Predictive equations were developed for gas adsorption. From these equations, the maximum difference between chamber inlet and outlet concentrations of NH3 or H2S was predicted to be 7.5% at the lowest concentration used for either gas. In the calculation of emission factors for NH3 and H2S, no adsorption correction factor is recommended for concentrations >37,500 ppb and 2100 ppb for NH3 and H2S, respectively. The reported differences in outlet and inlet concentration above these ranges are outside the fullscale sensitivity of the gas sensing equipment. The use of 46-90 m of Teflon tubing with the flux chambers has apparently no effect on gas adsorption, because recovery was completed almost instantaneously at the beginning of the tests.  相似文献   

13.
In order to remove high concentrations of hydrogen sulfide (H2S) gas from anaerobic wastewater treatments in livestock farming, a novel process was evaluated for H2S gas abatement involving the combination of chemical absorption and biological oxidation processes. In this study, the extensive experiments evaluating the removal efficiency, capacity, and removal characteristics of H2S gas by the chemical absorption reactor were conducted in a continuous operation. In addition, the effects of initial Fe2+ concentrations, pH, and glucose concentrations on Fe2+ oxidation by Thiobacillus ferrooxidans CP9 were also examined. The results showed that the chemical process exhibited high removal efficiencies with H2S concentrations up to 300 ppm, and nearly no acclimation time was required. The limitation of mass-transfer was verified as the rate-determining step in the chemical reaction through model validation. The Fe2+ production rate was clearly affected by the inlet gas concentration as well as flow rate and a prediction equation of ferrous production was established. The optimal operating conditions for the biological oxidation process were below pH 2.3 and 35 degrees C in which more than 90% Fe3+ formation ratio was achieved. Interestingly, the optimal glucose concentration in the medium was 0.1%, which favored Fe2+ oxidation and the growth of T. ferrooxidans CP9.  相似文献   

14.
Gaseous NH3 removal was studied in laboratory-scale biofilters (14-L reactor volume) containing perlite inoculated with a nitrifying enrichment culture. These biofilters received 6 L/min of airflow with inlet NH3 concentrations of 20 or 50 ppm, and removed more than 99.99% of the NH3 for the period of operation (101, 102 days). Comparison between an active reactor and an autoclaved control indicated that NH3 removal resulted from nitrification directly, as well as from enhanced absorption resulting from acidity produced by nitrification. Spatial distribution studies (20 ppm only) after 8 days of operation showed that nearly 95% of the NH3 could be accounted for in the lower 25% of the biofilter matrix, proximate to the port of entry. Periodic analysis of the biofilter material (20 and 50 ppm) showed accumulation of the nitrification product NO3- early in the operation, but later both NO2- and NO3- accumulated. Additionally, the N-mass balance accountability dropped from near 100% early in the experiments to approximately 95 and 75% for the 20- and 50-ppm biofilters, respectively. A partial contributing factor to this drop in mass balance accountability was the production of NO and N2O, which were detected in the biofilter exhaust.  相似文献   

15.
A polysulfone microporous membrane module was investigated for control of 1-butanol-contaminated gas streams. A diurnal loading condition, using two different butanol concentrations, was used to simulate start-up and stop conditions associated with shift work. The membrane module was also used to remove 1-butanol from air under continuous loading conditions in a bioreactor. The reactors were seeded with a mixed bacterial consortium capable of butanol biodegradation. Biokinetic parameters for butanol utilization were determined for the culture to be a maximum specific utilization rate (k) equal to 4.3 d(-1) and a half saturation constant (Ks) equal to 8.9 mg L(-1). A biofilter running only with diurnal loading conditions giving a "40-hr work-week" had an average 1-butanol removal rate of 29% (111 ppm, 74 gm(-3) hr(-1)) from a 350-ppm influent at the end of an 8-hr operational day. End-of-day removal varied between 4 and 67% during the operational period. With continuous steady-state operation followed by placement on a diurnal loading schedule and influent butanol concentrations increased to 700 ppm, butanol removal averaged 38% (269 ppm, 145 gm-3 hr(-1)). Under continuous loading, steady-state conditions, 1-butanol removal from the airstream was greater than 99% (200 ppm, 73 gm-3 hr(-1)). These results suggest that the bioreactor can be operated on a diurnal schedule or 40-hr week operational schedule without any decline in performance.  相似文献   

16.
It is a common practice in the midwestern United States to raise swine in buildings with under-floor slurry storage systems designed to store manure for up to one year. These so-called "deep-pit" systems are a concentrated source for the emissions of ammonia (NH3), hydrogen sulfide (H2S), and odors. As part of a larger six-state research effort (U.S. Department of Agriculture-Initiative for Future Agriculture and Food Systems Project, "Aerial Pollutant Emissions from Confined Animal Buildings"), realtime NH3 and H2S with incremental odor emission data were collected for two annual slurry removal events. For this study, two 1000-head deep-pit swine finishing facilities in central Iowa were monitored with one-year storage of slurry maintained in a 2.4 m-deep concrete pit (or holding tank) below the animal-occupied zone. Results show that the H2S emission, measured during four independent slurry removal events over two years, increased by an average of 61.9 times relative to the before-removal H2S emission levels. This increase persisted during the agitation process of the slurry that on average occurred over an 8-hr time period. At the conclusion of slurry agitation, the H2S emission decreased by an average of 10.4 times the before-removal emission level. NH3 emission during agitation increased by an average of 4.6 times the before-removal emission level and increased by an average of 1.5 times the before-removal emission level after slurry removal was completed. Odor emission increased by a factor of 3.4 times the before-removal odor emission level and decreased after the slurry-removal event by a factor of 5.6 times the before-removal emission level. The results indicate that maintaining an adequate barn ventilation rate regardless of animal comfort demand is essential to keeping gas levels inside the barn below hazardous levels.  相似文献   

17.
A high H2S concentration inhibits nitrification when H2S and NH3 are simultaneously treated in a single biofilter. To improve NH3 removal from waste gases containing concentrated H2S, a two-stage biofilter was designed to solve the problem. In this study, the first biofilter, inoculated with Thiobacillus thioparus, was intended mainly to remove H2S and to reduce the effect of H2S concentration on nitrification in the second biofilter, and the second biofilter, inoculated with Nitrosomonas europaea, was to remove NH3. Extensive studies, which took into account the characteristics of gas removal, the engineering properties of the two biofilters, and biological parameters, were conducted in a 210-day operation. The results showed that an average 98% removal efficiency for H2S and a 100% removal efficiency for NH3 (empty bed retention time = 23-180 sec) were achieved after 70 days. The maximum degradation rate for NH3 was measured as 2.35 g N day(-1) kg of dry granular activated carbon(-1). Inhibition of nitrification was not found in the biofilter. This two-stage biofilter also exhibited good adaptability to shock loading and shutdown periods. Analysis of metabolic product and observation of the bacterial community revealed no obvious acidification or alkalinity phenomena. In addition, a lower moisture content (approximately 40%) for microbial survival and low pressure drop (average 24.39 mm H2O m(-1)) for system operation demonstrated that the two-stage biofilter was energy saving and economic. Thus, the two-stage biofilter is a feasible system to enhance NH3 removal in the concentrated coexistence of H2S.  相似文献   

18.
基于膜吸收技术自制双层平板式膜吸收器,搭建净化低浓度甲醛和氨气污染模拟系统,考察不同膜结构参数、进气流量、吸收剂流量等因素对其净化效果的影响。结果表明,聚偏氟乙烯PVDF对低浓度甲醛和氨气的净化效率高于聚四氟乙烯PTFE。对同一材质膜,随着膜孔隙率的增大,甲醛和氨气的净化率呈上升趋势。随着进气流量的增加。甲醛和氨气的净化效率降低;而吸收剂流量对其净化效率影响不大。对于所有实验条件,平均膜孔径为0.22μm的PVDF4#在进气流量ug=120L/h时,甲醛和氨气的净化效率最高,分别达94.7%和96.3%。  相似文献   

19.
运用连续式生物吸收处理工艺,以废糖蜜发酵液作为碳源进行了微生物法去除SO2气体的研究,在简单粗放的实验条件下,研究了脱硫脱硫弧菌对较大气量SO2气体的去除效果,并对产物H2S在第二级生物反应器中的去除率进行了测定。实验结果表明,随着进气量由0.18 m3/h增大至5 m3/h,脱硫率会降低,但是随之提高搅拌速度和补料速度后,脱硫率又恢复到较高水平,当搅拌速度为590 r/min时,5 L生物反应液可以处理5 m3/h的SO2气体,1#反应器SO2去除率和2#反应器H2S去除率分别达到92%和98%以上。在气量增至5 m3/h时,1#和2#反应器补料流速分别为175 mL/h和200 mL/h时,没有亚硫酸盐和硫化物的积累,pH值和菌体浓度稳定,系统运行良好。  相似文献   

20.
Alagappan G  Cowan RM 《Chemosphere》2004,54(8):1255-1265
Batch experiments were conducted to determine the effect of temperature and dissolved oxygen concentration on the rates of growth and substrate (benzene and toluene) degradation by the toluene degrading strain, Pseudomonas putida F1. Over a range of temperature from 15 to 35 degrees C the maximum specific growth rate followed the Topiwala-Sinclair relationship when either benzene or toluene served as the sole carbon and energy source. Oxygen limited growth followed Monod saturation kinetics with the specific growth rate given as a function of the dissolved oxygen concentration. The oxygen half-saturation coefficient was found to be approximately 1 mg/l regardless of whether benzene or toluene was the substrate. Similar experiments with Burkholderia (Ralstonia) pickettii PKO1 for grown on toluene revealed an oxygen half-saturation coefficient of 0.7 mg/l.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏