首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In this study, traditional Soxhlet, automatic Soxhlet and ultrasonic extraction techniques were employed to determine the speciation and concentration of polycyclic aromatic hydrocarbons (PAHs) on lime spray dryer (LSD) ash samples collected from the baghouse of a spreader stoker boiler. To test the efficiencies of different extraction methods, LSD ash samples were doped with a mixture of 16 US EPA specified PAHs to measure the matrix spike recoveries. The results showed that the spike recoveries of PAHs were different using these three extraction methods with dichloromethane (DCM) as the solvent. Traditional Soxhlet extraction achieved slightly higher recoveries than automatic Soxhlet and ultrasonic extraction. Different solvents including toluene, DCM:acetone (1:1 V/V) and hexane:acetone (1:1 V/V) were further examined to optimize the recovery using ultrasonic extraction. Toluene achieved the highest spike recoveries of PAHs at a spike level of 10 microg kg(-1). When the spike level was increased to 50 microg kg(-1), the spike recoveries of PAHs also correspondingly increased. Although the type and concentration of PAHs detected on LSD ash samples by different extraction methods varied, the concentration of each detected PAH was consistently low, at microg kg(-1) levels.  相似文献   

2.
不同萃取方法对长江口边滩多环芳烃萃取效果的影响   总被引:2,自引:0,他引:2  
选取索氏提取法和加速溶剂萃取仪(ASE)提取法,对长江口边滩样品进行多环芳烃萃取实验,并利用气相色谱/质谱仪对萃取出来的多环芳烃进行定量分析,研究了不同萃取方法以及不同溶剂条件下多环芳烃的总量、分布特征.结果表明,长江口边滩多环芳烃最高值出现在吴淞口;索氏提取法在多环芳烃萃取效果上优于加速溶剂萃取仪提取法;混合溶剂萃取...  相似文献   

3.
Shu YY  Lai TL  Lin HS  Yang TC  Chang CP 《Chemosphere》2003,52(10):1667-1676
As part of an evaluation of focused microwave-assisted extraction (FMAE) using an open-vessel system, the effects of matrix, moisture content, ageing, and solvent have been studied on the extraction efficiency of polycyclic aromatic hydrocarbons (PAHs) from spiked soils. PAHs were spiked onto three different uncontaminated air dried and originally wet soil matrices with 1- and 20-day ageing periods. Solvents used were hexane–acetone (1:1), cyclohexane–acetone (1:1) and dichloromethane. FMAE only required a small amount of solvent (20 ml) and short extraction time (10 min) in the open cell under 90 W of microwave power. The results revealed that the extraction efficiency strongly depends on the nature of soil matrix; moisture content may enhance the recoveries of PAHs for many cases; and, the influence of the type of solvent is not significant. A comparison between microwave extraction and 16-h Soxhlet extraction has been made on spiked soils. It evidenced that the microwave method under ambient pressure is a suitable alternative to Soxhlet method for the analysis of PAHs in soils. For the evaluation of the developed FMAE method, three reference materials were used. The PAHs recovered from three reference materials were in a good agreement with reference values.  相似文献   

4.
Song YF  Jing X  Fleischmann S  Wilke BM 《Chemosphere》2002,48(9):993-1001
The following four methods were compared on the extraction efficiency of 16 EPA (US Environmental Protection Agency) polycyclic aromatic hydrocarbons (PAHs): German method of the Verband Deutscher Landwirtschaftlicher Untersuchungs und Forschungsanstalten (VDLUFA), two methods of the International Organization for Standardization using shaking (ISO A) and Soxhlet extraction (ISO B) and an ultrasonic method. Recovery rates of 16 PAHs were determined in two soils. Extraction efficiency was evaluated in five soils and three sediments. Effect of drying soils and sediments on extraction efficiency was tested using the VDLUFA and the ultrasonic methods. Our study shows that the number of aromatic rings, rather than extraction procedures, significantly influenced recovery rates of individual PAHs. No significant differences in extraction efficiency of the four methods were observed for less polluted samples. For highly polluted soils, extraction efficiency decreased in the following order: VDLUFA method > ISO A > ultrasonic method > ISO B. Influence of soil moisture on extraction efficiency depended to some extent on both solvent used and content of PAHs in samples. A mixture of dichloromethane/acetone (5:1) is recommended for PAH extraction from moist samples when the ultrasonic method is used.  相似文献   

5.
The contents of nonhydrolyzable organic matter (NHC) and black carbon (BC) were measured in soils and sediments from the Pearl River Delta, South China. Polycyclic aromatic hydrocarbons (PAHs) were extracted respectively by Soxhlet and an accelerated solvent extraction device (ASE) using different solvents. In addition, sequential aqueous leaching at different temperatures was carried out. The PAH content extracted with the sequential three solvent ASE is two times higher than that using the Soxhlet extraction method. The relationship of the PAH content with the NHC content is very significant. The PAH concentrations measured at various temperature steps fit well to the Van't Hoff equation and the enthalpy was estimated. The investigation indicates that condensed organic matter such as kerogen carbon, aged organic matter, and BC is relevant for the extraction and distribution of native PAHs in the investigated field soils and sediments.  相似文献   

6.
L. Stieglitz  G. Zwick  W. Roth 《Chemosphere》1986,15(9-12):1135-1140
A number of different pretreatment and extraction procedures were compared with regard to recovery of PCDD/PCDF from fly ash. Highest results were obtained using an acid digestion with excess dilute HCl, followed by freeze drying of the residue and hot extraction by toluene.  相似文献   

7.
Kemmochi Y  Tsutsumi K 《Chemosphere》2001,43(4-7):433-437
A rapid screening method for the polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) in fly ash has been developed. The screening is done in two steps: (a) the extraction by the accelerated solvent extraction and (b) the quantitative measurement by ion trap tandem mass spectrometer (MS/MS). Anhydrous sodium sulfate was added to the fly ash containing activated carbon in order to increase the extraction efficiency. The selectivity of the ion trap MS/MS was confirmed with 13C-labelled internal standard. Then the results of the screening method were compared with those obtained by the conventional analytical method using high-resolution mass spectrometer (HRMS).  相似文献   

8.
Kobayashi T  Morimoto K  Tatsumi K 《Chemosphere》2008,70(11):2002-2008
Plants contain a wide variety of chemicals, some of which may have similar chromatographic behavior to polycyclic aromatic hydrocarbons (PAHs). During solid phase extraction (SPE) with Si-gel for instance, the co-elution of carotene-like colored compounds with PAHs has been observed. In this paper, liquid–liquid extraction was applied for the separation and subsequent analysis of PAHs from plant extracts. PAHs containing 2–6 rings, which include naphthalene, phenanthrene, pyrene, benzo[a]pyrene and benzo[ghi]perylene, were used as representative target chemicals. Carotene-like compounds extracted from Komatsuna (Brassica campestris) shoot by acetone followed by Si-gel treatment were incorporated as undesired components in the model matrix. Results showed the feasibility of employing either acetonitrile or 2% (w/v) KOH–methanol as solvents for high PAHs recovery and low extraction of colored fraction. For acetonitrile, 86.9–93.5% of each PAH could be recovered after three extraction cycles (relative standard deviation, RSD < 1.6%) with only about 10% co-extraction of colored fraction. For 2% KOH–methanol, PAHs recoveries ranging from 79.3% to 83.1% after five cycles (RSD < 1.5%) were achieved while the percent extraction of colored fraction was also low at 10%. The relatively higher selectivity of the solvents for PAHs over the colored fraction as well as the solubility of the matrix solution in the solvent may have contributed to these results. On this basis, liquid–liquid extraction is very useful for the pre-treatment of plant extracts for PAHs analysis.  相似文献   

9.
Sonolytic reactions of phenanthrene in organic extraction solutions   总被引:2,自引:0,他引:2  
Sun P  Weavers LK 《Chemosphere》2006,65(11):2268-2274
Ultrasonic extraction is a common method used to extract semi-volatile and nonvolatile organic compounds such as polycyclic aromatic hydrocarbons (PAHs) from solid matrices. However, ultrasonic energy has been suspected to lead to undesired reactions of the solute and thus affect qualitative and quantitative results. In this paper, sonolytic reactions of phenanthrene in common organic extraction solutions were examined using a 20 kHz ultrasonic probe under conditions commonly used for ultrasonic extraction. Extraction parameters including phenanthrene concentration, solvent type, pulse length, and sonication time were investigated. Hexane:acetone (1:1 V/V) resulted in less phenanthrene degradation than dichloromethane (DCM):acetone (1:1 V/V). Initial solute concentration, length of sonication time, and solvent type affected the degradation of phenanthrene. Reaction byproducts including methylphenanthrene and methylnaphthalene detected after sonication indicate that phenanthrene reacts by both direct pyrolysis and reaction with methyl or ethyl radicals formed from solvent pyrolysis.  相似文献   

10.
Zhou HC  Zhong ZP  Jin BS  Huang YJ  Xiao R 《Chemosphere》2005,59(6):861-869
This paper presents the incineration tests of municipal solid waste (MSW) in a fluidized bed and the adsorption of activated carbon (AC) on polycyclic aromatic hydrocarbons (PAHs). An extraction and high performance liquid chromatography (HPLC) technique was used to analyze the concentrations of the 16 US EPA specified PAHs contained in raw MSW, flue gas, fly ash, and bottom ash. The aim of this work was to decide the influence of AC on the distribution of PAHs during the incineration of MSW. Experimental researches show that there were a few PAHs in MSW and bottom ash. With the increase of AC feeding rate, the concentrations of three- to six-ring PAHs in fly ash increased, and the concentration of two-ring PAH decreased. The total-PAHs in flue gas were dominated by three-, and four-ring PAHs, but a few two-, five-ring PAHs and no six-ring PAHs were found. PAHs could be removed effectively from flue gas by using in-duct AC injection and the removal efficiencies of PAHs were about 76-91%. In addition, the total toxic equivalent (TEQ) concentrations of PAH in raw MSW, bottom ash, fly ash, and flue gas were 1.24 mg TEQ kg-1, 0.25 mg TEQ kg-1, 6.89-9.67 mg TEQ kg-1, and 0.36-1.50 microg TEQ Nm-3, respectively.  相似文献   

11.
Supercritical fluid extraction (SFE) was used to extract polycyclic aromatic hydrocarbons (PAH) from a certified sample of marine sediment. This sample contains a great number of organic pollutants that are present in low concentrations. The extractions were carried out at 50 and 80 degrees C, at a pressure varying from 230 to 600 bar and using CO2 in the supercritical phase and the effect of three organic modifiers (methanol, n-hexane and toluene), added at 5%/vol, at the same temperature and pressure conditions, were then considered. PAHs were characterized by GC-MS and the recover yield was estimated for 6 PAHs that were representative of those present in the sample, according to their molecular weight and to the number of condensed rings. The analytical conditions giving the best recovery efficiency were used on an unpolluted soil sample spiked with 11 PAHs of environmental importance at a concentration similar to that certified for the sediment sample. An increase in the yield of recovered PAHs, using methanol as co-solvent, was observed while higher temperatures caused a negative effect on the quantity of recovered pollutants. The recovery yield for PAHs from the spiked soil sample was measured and found to be greater than 90%. Better recoveries were obtained for those compounds with higher molecular weight.  相似文献   

12.
A rapid analytical approach for determination of polycyclic aromatic hydrocarbons (PAHs) present in real samples of particulate matter (PM10 filters) was investigated, based on the use of water under sub critical conditions, and the subsequent determination by GC-MS (SIM). The method avoids the use of large volumes of organic solvents as dichloromethane, toluene or other unhealthy liquid organic mixtures which are normally used in time-consuming conventional sample preparation methods. By using leaching times <1 h, the method allows determination of PAHs in the range of ng/m3 (detection limits between 0.05 and 0.2 ng/m3 for 1458 m3 of sampled air) with a precision expressed as RSD between 5.6% and 11.2%. The main idea behind this approach is to raise the temperature and pressure of water inside a miniaturized laboratory-made extraction unit and to decrease its dielectric constant from 80 to nearly 20. This effect allows an increase in the solubility of low polarity hydrocarbons such as PAHs. In this way, an extraction step of a few minutes can be sufficient for a quantitative extraction of airborne particles collected in high volume PM10 samplers. Parameters such as: extraction flow, static or dynamic extraction times and water volume were optimized by using a standard reference material. Technical details are given and a comparison using real samples is made between the conventional Soxhlet extraction method and the proposed approach.The proposed approach can be used as a quantitative method to characterize low molecular PAHs and simultaneously as a screening method for high molecular weight PAHs, because the recoveries are not quantitative for molecular weights over 202. In the specific case of the Santiago metropolitan area, due to the frequent occurrence of particulate matter during high pollution episodes, this approach was applied as an efficient short-time screening method for urban PAHs. Application of this screening method is recommended especially during the winter, when periods of clear detriment of the atmospheric and meteorological conditions occur in the area.  相似文献   

13.
A procedure was developed for determination of 16 polycyclic aromatic hydrocarbons (PAHs) in heavily contaminated paddy soil from wastewater irrigated farmland near Tianjin. The sample was distilled with accelerated solvent extraction (ASE), purified by a silica gel column, and measured with GC/MS. The optimal conditions for the distillation were at 140 degrees C (1500 psi) with a 1:1 mixture of dichloromethane and acetone for 5 min. Application of cyclohexane for extract transfer improved the recovery when the ASE extraction was followed by a silica gel cleanup procedure. Recoveries from the method for 16 PAHs ranged from 57-140% with the coefficients of variation of the results ranging from 0.35% to 5.75%. The total 16 PAHs in a composite sample collected from a wastewater irrigated paddy field near Tianjin was 3.90 mg/kg.  相似文献   

14.
This study deals with a new sample extraction technique which minimizes pollution in analytical laboratories whilst reducing sample preparation time and cost. The device uses the Randall technique for solid sample extraction, performed by immersion of the sample in boiling solvent. The fast solubilization operated by the hot solvent leads to a sharp reduction in extraction time. This method was tested for the extraction of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) from different solid matrices using toluene as extractant, and compared with the conventional Soxhlet. The reduction in the extraction times (from 48 to 2 h) with an efficiency similar to or higher than that afforded by the conventional Soxhlet technique indicates the suitability of this method.  相似文献   

15.
Okuda T  Naoi D  Tenmoku M  Tanaka S  He K  Ma Y  Yang F  Lei Y  Jia Y  Zhang D 《Chemosphere》2006,65(3):427-435
We developed a useful analytical method for the determination of polycyclic aromatic hydrocarbons (PAH) concentrations in the aerosol of China. We used an accelerated solvent extraction (ASE) method for the extraction of PAHs from the aerosol samples, in order to reduce the extraction time and the solvent volume used. The optimum purification method was developed, with aminopropylsilane chemically-bonded stationary-phase column chromatography, in order to remove many co-extractives which cannot be removed by conventional purification methods using silica-gel column chromatography. HPLC/fluorescence detection (FLD) was adopted as the analytical method, because it has very high sensitivity to PAH and it is easy to install, operate, and maintain as compared with GC/MS. With the analytical method developed in this study, the recovery and precision (RSD) for most of the PAHs ranged from 75% to 129% and from 2.8% to 22.7%, respectively. The concentrations of PAHs in the aerosol samples collected from October 2003 to April 2005 in Beijing, China were determined using the newly developed method. SigmaPAHs, which is the sum of the concentrations of all detected PAHs, was 177.8 +/- 239.9 ng m(-3) (n = 64). The SigmaPAHs concentration in the heating season (305.1 +/- 279.0 ng m(-3), n = 33) was 7.2 times higher than that in the non-heating season (42.3 +/- 32.0 ng m(-3), n = 31). These strong seasonal variations in atmospheric PAH concentration are possibly due to coal combustion for residential heating in winter.  相似文献   

16.
Interest in vegetable oil extracted from idioblast cells of avocado fruit is growing. In this study, five extraction methods to produce avocado oil have been compared: traditional solvent extraction using a Soxhlet or ultrasound, Soxhlet extraction combined with microwave or ultra-turrax treatment and supercritical fluid extraction (SFE). Traditional Soxhlet extraction produced the most reproducible results, 64.76 ± 0.24 g oil/100 g dry weight (DW) and 63.67 ± 0.20 g oil/100 g DW for Hass and Fuerte varieties, respectively. Microwave extraction gave the highest yield of oil (69.94%) from the Hass variety. Oils from microwave extraction had the highest fatty acid content; oils from SFE had wider range of fatty acids. Oils from Fuerte variety had a higher monounsaturated: saturated FA ratio (3.45–3.70). SFE and microwave extraction produced the best quality oil, better than traditional Soxhlet extraction, with the least amount of oxidizing metals present.  相似文献   

17.
A new analytical method using accelerated solvent extraction was developed for the determination of 10 particle-associated polar and semipolar pesticides. In addition, six deuterated analogues of the target compounds were evaluated as internal standards. The method yielded acceptable accuracy (73–103% recovery) and precision (<25% relative standard deviation) for eight compounds. Using size exclusion chromatography (SEC) as cleanup step resulted in higher recoveries compared to solid phase extraction (SPE) cleanup.

Deuterated standards with 10 or more deuterium atoms performed well as internal standards concerning similar recovery and correlation with the target analytes.

The method was employed to extract particle-associated pesticides from 16 streams located in an area with intense agriculture in France. Acetochlor, pirimicarb, tebuconazole, fenpropidin, -endosulfan and chlorfenvinphos were detected at concentrations up to 1 mg kg−1 dry weight. A comparison with aquatic toxicity data indicated potential risk to the benthic fauna exposed to these concentrations of pirimicarb, -endosulfan and chlorfenvinphos.

We suggest that the method presented here be used for the extraction and quantitation of particle-associated polar pesticides.  相似文献   


18.
Shu YY  Lao RC  Chiu CH  Turle R 《Chemosphere》2000,41(11):1709-1716
The microwave-assisted extraction (MAE) of polycyclic aromatic hydrocarbons (PAHs) from harbor sediment reference material EC-1, marine sediment reference material HS-2 and PAH-spiked river bed soil was conducted. The extraction conditions for EC-1 were carried out at 70 degrees C and 100 degrees C under pressure in closed vessels with cyclohexane acetone (1:1), cyclohexane-water (3:1), hexane acetone (1:1), and hexane-water (3:1) for 10 min. A comparison between MAE and a 16-h Soxhlet extraction (SX) method showed that both techniques gave comparable results with certified values. MAE has advantages over the currently used Soxhlet technique due to a faster extraction time and lower quantity of solvent used. The consumption of organic solvent of the microwave method was less than one-tenth compared to Soxhlet.  相似文献   

19.
ABSTRACT

Heavy metal and polycyclic aromatic hydrocarbons (PAHs) in flue gas have received considerable attention in recent years due to their mutagenic or carcinogenic properties. The present study is carried out to investigate the influence of the quantity of heavy metals on PAHs formation in fly ash.

A fluidized bed incinerator was used in this experiment to obtain fly ash of chemical similarity by incinerating various compositions of waste. The obtained fly ash, both with and without heavy metal, were used to adsorb the PAHs in the flue gas and to investigate the formation of PAHs in fly ash. The results indicate that carbon and heavy metals most greatly influence the formation of PAHs in the fly ash. Carbon is absorptive; heavy metals encourage not only absorption of PAHs but also catalyze PAHs formation.  相似文献   

20.
Fly ashes from a lignite fired power plant and a municipal incinerator were leached for 3 hours using 0.1N HC1. Leachate was analyzed for Cd and Mn and plots of concentration versus time for these elements show Cd, a surface adsorbed element in the combustion process, to be rapidly removed from the ash particles in the initial four or five minutes of leaching. Manganese, a fly ash matrix element, is leached at a more constant rate as the ash praticles are dissolved. Total Cd and Mn concentrations in the incinerator fly ash are greater than total concentrations of these elements in the lignite fly ash.  相似文献   