首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A multiresidue method was developed to determine 19 carbamate pesticides in tea samples. Optimizations of different parameters, such as the type of extraction solvents, clean-up cartridges, and elution solvents were carried out. The developed method used acetonitrile as extraction solvent, amino cartridge for adsorbents and acetone-n-hexane as the eluting solution. Nineteen carbamate residues were then analyzed by high-pressure liquid chromatography (HPLC) with fluorescence detector. The present results showed good linearity by correlation coefficients of more than 0.9999 for all analyses. Limits of detection and quantification varied from 0.0005–0.023 mg L? 1, 0.008–0.077 mg L? 1, respectively. Recoveries of sixteen carbamate pesticides ranged from 65% to 135% at the spiked level of 0.5, 1.0 and 2.0 mg L? 1. The relative standard deviations were lower than 20% and coefficient of variations were lower than 15%. The results indicate that the proposed method provides an effective multi and trace level screening determination of carbamate pesticides residues for tea samples.  相似文献   

2.
高碘酸钾氧化中性红测定间苯二酚   总被引:3,自引:0,他引:3  
在酸性和75℃条件下,微量的间苯二酚对高碘酸钾氧化中性红褪色反应具有显著的抑制作用,据此建立了测定间苯二酚的新的动力学光度法。该方法灵敏、快速、操作简便,此法的线性范围为0.1~3.0μg/mL,检出限为0.082μg/mL,对1.0μg/mL的间苯二酚测定11次的相对标准偏差为2.26%。  相似文献   

3.
4.
Abstract

Carbofuran was applied over seeded rutabaga cv. York and residues (corrected for recovery) of carbofuran, 3‐hydroxy‐ and 3‐ketocarbofuran in the harvested roots averaged 0.15, 0.23 and 0.07 ppm in peel and 0.09, 0.14 and 0.05 ppm in pulp, respectively. Samples were extracted by hot acid digestion, partitioned in methylene chloride and cleaned up on Florisil. The 3‐hydroxy‐carbofuran was ethoxylated and the compounds were converted into their dinitrophenyl ethers and analysed by electron capture gas chromatography using 3% OV‐3 column.  相似文献   

5.
Baygon was administered IG once daily to CD rats (5 to 50 mg/kg), on the 7th-19th day of gestation or to CD-1 mice (5 to 60 mg/kg) on days 6-16 of gestation. Baygon, at dose levels which were not maternally lethal, did not produce fetotoxicity, fetal lethality or malformations in the fetuses. Baygon was not teratogenic in the CD rat or CD-1 mouse at maternally nontoxic dose levels. Carbofuran was administered IG once daily to CD rats (0.05 to 5.0 mg/kg), on the 7th-19th day of gestation or to CD-1 mice (0.1 to 20 mg/kg) on days 6-16 of gestation. At dose levels which were not maternally lethal, carbofuran did not produce fetotoxicity, fetal lethality or malformations in the fetuses. Carbofuran was not teratogenic in the CD rat or CD-1 mouse at maternally nontoxic dose levels. Dimethoate was administered IG once daily to CD-1 mice (10 to 80 mg/kg), on the 6th-16th day of gestation. At dose levels which were not maternally lethal, dimethoate did not produce fetotoxicity, fetal lethality or malformations in the fetuses. Dimethoate was not teratogenic in the CD-1 mouse at maternally nontoxic dose levels. EPN was administered IG once daily to CD-1 mice (1.0 to 12.0 mg/kg) on the 6th-16th day of gestation. EPN, at dose levels up to those which were maternally lethal, did not produce fetotoxicity, fetal lethality or an increase in malformations. EPN was not teratogenic in the CD-1 mouse at maternally nontoxic dose levels.  相似文献   

6.
An extraction method based on matrix solid-phase dispersion was developed to determine pirimicarb, methyl parathion, malathion, procymidone, α -endosulfan and β -endosulfan in lettuce using gas chromatography-mass spectrometry. The best results were obtained using 4.0 g of lettuce, 2.0 g of silica as dispersant sorbent, 0.1 g of activated carbon as clean up sorbent and acetonitrile as eluting solvent. The method was validated using lettuce samples fortified with pesticides at six different concentration levels (0.1 to 2.0 mg/kg). Average recoveries (7 replicates) ranged from 50 to 120 %, with relative standard deviations between 0.6 and 8.0 %. Detection and quantification limits for lettuce ranged from 0.01 to 0.02 mg/kg and 0.04 to 0.10 mg/kg, respectively.  相似文献   

7.
A method for determining atrazine in soil extracts was evaluated by flow injection analysis with spectrophotometric detection. The method is based on the reaction of atrazine with pyridine in an acid medium followed by the reaction with NaOH and sulfanilic acid. Several analytical conditions were previously studied and optimized. Under the best conditions of analysis, the limits of detection and quantification were 0.15 and 0.45 mg L?1, respectively, for a linear response between 0.50 and 2.50 mg L?1, and a sampling throughput of 21 determinations per hour. Using the standard addition method, the maximum relative standard deviation of 17% and recovery values between 80 and 100% were observed for three extracts from soil samples with different composition. The proposed method is simple, low-cost and easy to use, and can be employed for studies involving atrazine in soil samples or for screening of atrazine in soils.  相似文献   

8.
A headspace solid phase microextraction method (HS-SPME) for simultaneous determination of five pesticides belonging to triazine and organophosphorus pesticide groups in soil samples was developed. Microextraction conditions, such as temperature, extraction time and sodium chloride (NaCl) content were investigated and optimized using 100 μ m polydimethyl-siloxane (PDMS) fiber. Detection and quantification were done by gas chromatography-mass spectrometry (GC-MS). Relative standard deviation (RSD) and recovery values for multiple analysis of soil samples fortified at 30 μ g kg? 1 of each pesticide were below 13 % and higher than 70 %, respectively. Limits of detection (LOD) for all the compounds studied were less than 3.2 μ g kg? 1. The proposed method was applied in the analysis of some agricultural soil samples.  相似文献   

9.
Water quality assessment was conducted on the Ruiru River, a tributary of an important tropical river system in Kenya, to determine baseline river conditions for studies on the aquatic fate of N-methyl carbamate (NMC) pesticides. Measurements were taken at the end of the long rainy season in early June 2013. Concentrations of copper (0.21–1.51 ppm), nitrates (2.28–4.89 ppm) and phosphates (0.01–0.50 ppm) were detected at higher values than in uncontaminated waters, and attributed to surface runoff from agricultural activity in the surrounding area. Concentrations of dissolved oxygen (8–10 ppm), ammonia (0.02–0.22 ppm) and phenols (0.19–0.83 ppm) were found to lie within normal ranges. The Ruiru River was found to be slightly basic (pH 7.08–7.70) with a temperature of 17.8–21.2°C. The half-life values for hydrolysis of three NMC pesticides (carbofuran, carbaryl and propoxur) used in the area were measured under laboratory conditions, revealing that rates of decay were influenced by the electronic nature of the NMCs. The hydrolysis half-lives at pH 9 and 18°C decreased in the order carbofuran (57.8 h) > propoxur (38.5 h) > carbaryl (19.3 h). In general, a decrease in the electron density of the NMC aromatic ring increases the acidity of the N-bound proton removed in the rate-limiting step of the hydrolysis mechanism. Our results are consistent with this prediction, and the most electron-poor NMC (carbaryl) hydrolyzed fastest, while the most electron-rich NMC (carbofuran) hydrolyzed slowest. Results from this study should provide baseline data for future studies on NMC pesticide chemical fate in the Ruiru River and similar tropical water systems.  相似文献   

10.
The possibility of applying thin layer chromatography (TLC) detection for the analysis of pesticide residues in tomatoes was investigated. Samples of tomatoes that have never been treated with pesticide were fortified with atrazine, carbaryl, carbofuran, chloroxuron, diuron, dimethoate, imazalil, oxamyl and methamidophos. The samples were extracted, cleaned-up by gel permeation chromatography and then applied on silica gel plates. The pesticides were eluted with ethyl acetate and dichloromethane. Two eluting solvent systems were tested, one using the reagents o-toluidine + potassium iodite (o-TKI) and the other p- nitrobenzene fluoroborate (NBFB). After the development of the plates, the diameter of the spots was measured. The lowest minimum detection quantity (MDQ) for o-TKI system for atrazine was 12 ng. The highest was 125 ng for carbofuran. Using NBFB system, the lowest MDQ was 60 ng for carbaryl and the highest was 70 ng obtained for carbofuran. Considering the concentration of these pesticides in the spiked tomato samples, the minimum concentration was 1.1 ng/microL and 32.3 ng/microL for atrazine and carbofuran, respectively, by using o-TKI system. For NBFB system the minimum concentration reached was 3.5 ng/microL and 4.3 ng/microL for carbaryl and carbofuran, respectively. This study showed that TLC can be used for semi-quantitative analysis.  相似文献   

11.
Pesticides are released intentionally into the environment and, through various processes, contaminate the environment. Three of the main classes of pesticides that pose a serious problem are organochlorines, organophosphates and carbamates. While pesticides are associated with many health effects, there is a lack of monitoring data on these contaminants. Traditional chromatographic methods are effective for the analysis of pesticides in the environment, but have limitations and prevent adequate monitoring. Enzymatic methods have been promoted for many years as an alternative method of detection of these pesticides. The main enzymes that have been utilised in this regard have been acetylcholinesterase, butyrylcholinesterase, alkaline phosphatase, organophosphorus hydrolase and tyrosinase. The enzymatic methods are based on the activation or inhibition of the enzyme by a pesticide which is proportional to the concentration of the pesticide. Research on enzymatic methods of detection, as well as some of the problems and challenges associated with these methods, is extensively discussed in this review. These methods can serve as a tool for screening large samples which can be followed up with the more traditional chromatographic methods of analysis.  相似文献   

12.
13.
The research objective was to adapt the ultraviolet (UV)-photolysis method to determine dissolved organic nitrogen (DON) in aqueous extracts of aerosol samples. DON was assumed to be the difference in total concentration of inorganic nitrogen forms before and after sample irradiation. Using a 2(2) factorial design the authors found that the optimal conversion of urea, amino acids (alanine, aspartic acid, glycine, and serine), and methylamine for a reactor temperature of 44 degrees C occurred at pH 2.0 with a 24-hr irradiance period at concentrations <33 microM of organic nitrogen. Different decomposition mechanisms were evident: the photolysis of amino acids and methylamine released mainly ammonium (NH4+), but urea released a near equimolar ratio of NH4+ and nitrate (NO3-). The method was applied to measure DON in the extracts of aerosol samples from Tampa, FL, over a 32-day sampling period. Average dissolved inorganic (DIN) and DON concentrations in the particulate matter fraction PM10 were 78.1 +/- 29.2 nmol-Nm(-3) and 8.3 +/- 4.9 nmol-Nm(-3), respectively. The ratio between DON and total dissolved nitrogen ([TDN] = DIN + DON) was 10.1 +/- 5.7%, and the majority of the DON (79.1 +/- 18.2%) was found in the fine particulate matter (PM2.5) fraction. The average concentrations of DIN and DON in the PM2.5 fraction were 54.4 +/- 25.6 nmol-Nm(-3) and 6.5 +/- 4.4 nmol-Nm(-3), respectively.  相似文献   

14.
A solid-phase microextraction -- coupled to a gas chromatography -- ion trap tandem mass spectrometry (SPME-GC-MS/MS) method was developed for the quantitative determination in rainwater of 8 pesticides amongst the most used in France and 3 triazines metabolites. The main factors affecting the SPME process were studied. Using a 3 mL sample, the method developed showed good linearity for concentrations ranging from 0.05 to 50 microgL(-1) with correlation coefficients between 0.997 and 0.9999 and relative standard deviations (% RSD) below 14%. The study of matrix effects showed that rainwater was too diluted to have any significant influence on the extraction efficiency. To validate the method, a field campaign was carried out on the rain events, which occurred in Strasbourg during a one-year period. The rain concentrations showed patterns of high pesticide concentrations during spring months, which were correlated to the spraying periods of most of these substances.  相似文献   

15.
催化光度法测定水中痕量亚硝酸根   总被引:5,自引:0,他引:5  
基于亚硝酸根对溴酸钾氧化结果紫而使其褪色的催化作用,建立了灵敏的催化光度测定痕量亚硝酸根的新方法,测定范围为0.02-0.16μg/mL,用于水样中亚硝酸根的测定,获得了满意结果。  相似文献   

16.
《Chemosphere》2013,92(3):233-246
Organochlorine pesticides (OCPs) can cause environmental damage and human health risks since they are lipophilic compounds with high resistance to degradation and long half-lives in humans. As most persistent OCPs have been banned years ago, it is expected to find these compounds at trace levels in environment. Therefore, increasingly sensitive and reliable analytical techniques are required to ensure effective monitoring of these compounds. The aim of this review is to discuss extraction and clean-up methods used to monitor OCP residues in milk, reported in the last 20 years. To carry out this review, an exhaustive bibliographic review was conducted. Despite the disadvantages of conventional extraction and clean-up methods, such as liquid–liquid, solid-phase or Soxhlet extractions, these procedures are still used due to their reliability. New extraction methods, like solid-phase microextraction, matrix solid-phase dispersion or QuEChERS, have not been thoroughly evaluated for OCP determination in milk. Almost all the methodologies analyzed in this review presented good performance characteristics according to the performance acceptability criteria set in SANCO’s procedure. Comparison between limits of quantification (LOQ) and detection (LOD), for the reported methodologies, is not always possible due to the heterogeneity of the units. Thus, researchers should take into account an homogenization of LOD and LOQ units, according to the international regulations and MRLs established. Finally, more research is necessary to obtain the ideal methodology for OCPs determination in milk, which comprises the environmentally friendly characteristics of the new techniques and the reliability of the traditional methodologies.  相似文献   

17.
A field method is described, which allows the qualitative estimation of pesticide contamination in the edgeof-field runoff. The method employs cheap and easy-to-use runoff sampling bottles, which were installed in an agricultural stream catchment over a period of three growing seasons. During this time 18 runoff events were detected, in nine of which insecticide contamination was measured (maximum concentrations: lindane 0.7 μg l−1 and 12.7 μg kg−1, parathion 20 μg l−1 and 728 μg kg, fenvalerate 18.4 μg 1-1 and 924 μg kg−1). These insecticides were detected mainly as particle-bound chemicals. On about 80 % of the occasions the presence or absence of runoff measured in the field was in agreement with a simulation of runoff presence or absence using the runoff model KINEROS.  相似文献   

18.
Abstract

A pressurized liquid extraction (PLE) method was presented for the determination of six neonicotinoid pesticides, acetamiprid, clothianidin, dinotefuran, imidacloprid, thiacloprid, and thiamethoxam in green onion. The critical parameters of PLE, e.g. extraction solvent, temperature, pressure, number of cycles, and static extraction time, were optimized by test on the spiked green onion with six neonicotinoids and the incurred green onion applied with four commercial neonicotinoid insecticide formulations (acetamiprid, dinotefuran, imidacloprid, and thiamethoxam). As a result, the recoveries of six neonicotinoids obtained by one cycle PLE with acetonitrile at 140?°C and 50?bar for 10?min were 94.7–99.5%. These results were acceptable according to the validation guideline for testing method of agricultural chemicals in food by Ministry of Health, Labour, and Welfare in Japan. PLE was also validated by the test on the incurred green onion. The analytical values of four neonicotinoids obtained by PLE were good agreement with those obtained by solid–liquid extraction with homogenizer, which is employed for Japanese official method for the analysis of pesticide residues in food (the ratios of analytical values obtained by PLE to those obtained by solid–liquid extraction were 99.7–101.2%). These results indicate that PLE is applicable for the determination of neonicotinoids in green onion.  相似文献   

19.
A rapid spectrophotometric determination of persulfate anion in ISCO   总被引:10,自引:0,他引:10  
Due to a gradual increase in the use of persulfate as an in situ chemical oxidation (ISCO) oxidant, a simple measurement of persulfate concentration is desirable to analyze persulfate distribution at designated time intervals on/off a site. Such a distribution helps evaluate efficacy of ISCO treatment at a site. This work proposes a spectrophotometric determination of persulfate based on modification of the iodometric titration method. The analysis of absorption spectra of a yellow color solution resulting from the reaction of persulfate and iodide in the presence of sodium bicarbonate reveals an absorbance at 352 nm, without significant interferences from the reagent matrix. The calibration graph was linear in the range of persulfate solution concentration of 0-70 mM at 352 nm. The proposed method is validated by the iodometric titration method. The solution pH was at near neutral and the presence of iron activator does not interfere with the absorption measurement. Also, analysis of persulfate in a groundwater sample using the proposed method indicates a good agreement with measurements by the titration method. This proposed spectrophotometric quantification of persulfate provides a simple and rapid method for evaluation of ISCO effectiveness at a remediation site.  相似文献   

20.
A solid-phase microextraction (SPME) procedure has been developed to extract eight organophosphorus pesticides (OPs) in water and the method was compared with a conventional solid phase extraction (SPE) technique. The extracted OPs were analyzed by gas chromatography using thermionic specific detection. Both extraction methods presented linear calibration at least over the concentration range investigated (100 to 1000 ng x mL(-1) for SPE and 1 to 100 ng x mL(-1) for SPME). SPME method presented higher sensitivity than SPE. The quantitation limits were between 0.1 to 1.0 ng x mL(-1) for SPME depending upon the analyte, and 100 ng x mL(-1) for SPE. The precision, as measured by the standard deviations (RSD), were in the range 3.6% to 5.8% for SPME and 2.4% to 9.2% for SPE. Along with the feature of being a solvent - free sampling technique, SPME offers additional benefits due to its high sensitivity, simplicity, and small size sample required (typically: SPE - 500 mL, SPME - 5 mL).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号