首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abstract

The long-term stability of a biofilter loaded with waste gases containing NH3 concentrations larger than 100 ppmv was studied in a laboratory-scale compost reactor. At an empty bed residence time (τ) of 21 sec, elimination capacities of more than 300 g NH3/m3/day were obtained at elimination efficiencies up to 87%. Because of absorption and nitrification, almost 80% of the NH3-N eliminated from the waste gas could be recovered in the compost as NH4+-N or NO2 ?/NO3 ?-N. The high elimination capacities could be maintained as long as the NH4+/NOx concentration in the carrier material was less than 4 g NH4+/NOx ?-N/kg wet compost. Above this critical value, osmotic effects inhibited the nitrifying activity, and the elimination capacity for NH3 decreased. To restore the biofilter performance, a carbon source (methanol) was added to reduce NH4+/NOx ? accumulated in the compost. Results indicate that methylotrophic microorganisms did convert NH4+/NOx ? into biomass, as long as the NO3 ? content in the compost was larger than 0.1 g NO3 ?-N/kg compost. Removal efficiencies of CH3OH of more than 90% were obtained at volumetric loads up to 11,000 g CH3OH/m3/day. It is shown that addition of CH3OH is a suitable technique for regenerating the compost material from osmotic inhibition as a result of high NH3 loading. The biofilter was operated for 4 months with alternating loading of NH3 and CH3OH.  相似文献   

2.
Long-term operation of biofilters for biological removal of ammonia   总被引:6,自引:0,他引:6  
Chen YX  Yin J  Wang KX 《Chemosphere》2005,58(8):1023-1030
Biological removal of ammonia was investigated using two types of packing materials, compost and sludge in laboratory-scale biofilters (8l reactor volume). The aim of this study is to investigate the potential of unit systems packed with these supports in terms of ammonia emissions treatment. Experimental tests and measurements included analysis of removal efficiency, metabolic products, and results of long-term operation. The inlet concentration of ammonia applied was 20-200 mg m-3. The ammonia loading rates of 24.9-566 g NH3 m-3 d-1 to compost biofilter (BF3) and 24.9-472 g NH3 m-3 d-1 to sludge biofilter (BF4) were applied for 210 days, respectively. Removal efficiencies of the compost and sludge biofilters were in the range of 97-99% and 95-99%, respectively when the inlet concentration of ammonia was below 110 mg m-3, and the maximum elimination capacities were 288 and 243 g NH3m-3d-1, respectively. However, removal efficiency and elimination capacity of both biofilters significantly decreased as the inlet concentration increased to above 110 mg m-3. By using kinetic analysis, the maximum removal rate of ammonia, Vm, and the saturation constant, Ks, were determined for both packing materials and the value of Vm for compost was found to be larger. Periodic analysis of the biofilter packing materials showed the accumulation of the nitrification product NO3- in the operation. During the experiment, the pressure drops measured were very low. The use of both packing materials requires neither nutritive aqueous solution nor buffer solution.  相似文献   

3.
Sewage sludge and yard waste compost were used as biofilter materials and tested with respect to their capacity for removing ammonia from air at different water contents. Ammonia removal was measured in biofilters containing compost wetted to different moisture contents ranging from air dry to field capacity (maximum water holding capacity). Filters were operated for 15 days and subsequently analyzed for NH3/NH4+, NO2-, and NO3-. The measured nitrogen species concentration profiles inside the filters were used to calculate ammonia removal rates. The results showed that ammonia removal is strongly dependent on the water content in the filter material. At gravimetric water contents below 0.25 g H2O g solids(-1) for the yard waste compost and 0.5 g H2O g solids(-1) ammonia removal rates were very low but increased rapidly above these values. The sewage sludge compost filters yielded more than twice the ammonia removal rate observed for yard waste compost likely because of a high initial concentration of nitrifying bacteria originating from the wastewater treatment process and a high airwater interphase surface area that facilitates effective ammonia dissolution and transport to the biofilm.  相似文献   

4.
Kim JH  Rene ER  Park HS 《Chemosphere》2007,68(2):274-280
The performance of a lab scale biofilter packed with biomedia, encapsulated by sodium alginate and polyvinyl alcohol was used for treating ammonia (NH(3)) gas at different loading rates. The metabolic end products during NH(3) oxidation were NH(4)(+), NO(3)(-) and NO(2)(-). It is noteworthy to mention that the immobilized cell biofilter required no separate acclimatization period and showed high removal efficiencies during the start of continuous experiments. The removal efficiency was nearly 100% when ammonia loading was 4.5gm(-3)h(-1) and the maximum elimination capacity achieved in this study was 5.5gNH(3)m(-3)h(-1) at a loading rate of 7.5gm(-3)h(-1). Shock loading studies were carried out to ascertain the response of the immobilized cells to fluctuations in inlet concentration and flow rate. The inlet loading rates were varied between 0.05 and 6gNH(3)m(-3)h(-1) during this phase of operation. The biofilter responded effectively to these shock loading conditions and recovered rapidly within 4-8h. Pressure drop values were consistently less and insignificant. The results from this study indicated that this immobilized cell biofilter could be considered as a potential option to treat NH(3) under steady and transient state operation.  相似文献   

5.
The removal capacity of carbon and nitrogen from an artificial leachate was evaluated by using laboratory-scale columns, and a design was proposed to remove nitrogen more efficiently from a semiaerobic landfill. Five columns (i.e., two artificial municipal waste columns under anaerobic and semiaerobic conditions, an artificial construction waste column under semiaerobic conditions, and two crushed stone columns under anaerobic and semiaerobic conditions) were used. The influent load rates of organics [g chemical oxygen demand (COD)/m3 x day], NH4+, NO3- and aeration conditions for the columns were varied, and the removal capacities of the columns for COD, NH4+-N, and NO3--N were measured. Among the packed column materials, crushed stone was shown to be most effective in removing COD, NH4+ N, and NO3--N from artificial leachate. Average removal rates of crushed column under the semiaerobic condition (column D) for COD and NH4+-N were estimated at about 150 g COD/m3 x day and 20 g COD/m3 x day, while those of crushed column under anaerobic condition (column E) for COD and NO3--N at about 400 and 150 g COD/m3 x day, respectively. It also was found that denitrification and nitrification reactions in column D occurred at the same time, and the ratio of denitrification to nitrification was estimated to be about 80%. Therefore, an anaerobic structure, which could be attached to the bottom of a main pipe in a semiaerobic landfill, is suggested to remove nitrogen and organic substances more effectively.  相似文献   

6.
Abstract

Carbonyl sulfide (COS) is an odor-causing compound and hazardous air pollutant emitted frequently from wastewater treatment facilities and chemical and primary metals industries. This study examined the effectiveness of biofiltration in removing COS. Specific objectives were to compare COS removal efficiency for various biofilter media; to determine whether hydrogen sulfide (H2S), which is frequently produced along with COS under anaerobic conditions, adversely impacts COS removal; and to determine the maximum elimination capacity of COS for use in biofilter design. Three laboratory-scale polyvinyl chlo-ride biofilter columns were filled with up to 28 in. of biofilter media (aged compost, fresh compost, wood chips, or a compost/wood chip mixture). Inlet COS ranged from 5 to 46 parts per million (ppm) (0.10–9.0 g/m3fihr). Compost and the compost/wood chip mixture produced higher COS removal efficiencies than wood chips alone. The compost and compost/wood chip mixture had a shorter stabilization times compared with wood chips alone. Fresh versus aged compost did not impact COS removal efficiency. The presence of H2S did not adversely impact COS removal for the concentration ratios tested. The maximum elimination capacity is at least 9 g/m3·hr for COS with compost media.  相似文献   

7.
The system performance of a trickle bed biofilter for treating single and mixed benzene, toluene, ethylbenzene, and o-xylene (BTEX) vapors from waste gases was investigated under different gas flow rates and influent BTEX concentrations. When a single substrate was fed, removal efficiencies of greater than 90% could be achieved for the loads below 64 g benzene/m3/hr, 110 g toluene/m3/hr, 53 g ethylbenzene/m3/hr, and 55 g o-xylene/m3/hr. When a mixed substrate was fed, removal efficiencies of each compound could be above 90% at BTEX loads below 96 g/m3/hr. The trickle bed biofilter appears to be an effective treatment process for removing both single and mixed BTEX vapors with low to high loads. Under similar substrate loads, BTEX vapors were preferentially biodegraded in the order of toluene, benzene, o-xylene, and ethylbenzene. The volumetric removal rates (elimination capacities) of BTEX vapors for a single-substrate feed were higher than those for a mixed-substrate feed under similar substrate loads; these differences were enhanced at higher substrate loads and less significant for a preferred substrate.  相似文献   

8.
Packing materials play a key role in the performance of bioreactors for waste gas treatment and particularly in biofilter applications. In this work, the performance of four differently packed biofilters operated in parallel for the treatment of relatively high inlet concentration of toluene was studied. The reactors were compared for determining the suitability of coconut fiber, digested sludge compost from a waste water treatment plant, peat and pine leaves as packing materials for biofiltration of toluene. A deep characterisation of materials was carried out. Biological activity and packing capabilities related to toluene removal were determined throughout 240 days of operation under different conditions of nutrients addition and watering regime. Also, biofilters recovering after a short shutdown was investigated. Nutrient addition resulted in improved removal efficiencies (RE) and elimination capacities (EC) of biofilters reaching maximum ECs between 75 and 95 g m(-3)h(-1) of toluene. In the first 80 days, the pH decreased progressively within the reactors, causing a population change from bacteria to fungi, which were the predominant decontaminant microorganisms thereafter. All reactors were found to recover the RE rapidly after a 5 days shutdown and, in a maximum of 7 days, all reactors had been completely recuperated. These results point out that fungal biofilters are a suitable choice to treat high loads of toluene. In general, coconut fiber and compost biofilters exhibited a better performance in terms of elimination capacity and long-term stability.  相似文献   

9.
Liou RM  Huang SN  Lin CW 《Chemosphere》2003,50(2):237-246
Flooded rice fields are one of the major biogenic methane sources. In this study, methane emission rates were measured after transplanting in paddy fields with application of two kinds of nitrogen fertilizers (ammonium sulfate, NH4+-N and potassium nitrate, NO3(-)-N) and with two kinds of rice varieties (Japonica and Indica). The experiment was conducted in fields located at Tainan District Agricultural Improvement Station in Chia-Yi county (23 degrees 25'08"N, 120 degrees 16'26"E) of southern Taiwan throughout the first and the second crop seasons in 1999. The seasonal methane flux in the first crop season with NH4+-N and NO3(-)-N ranged from 2.48 to 2.78 and from 8.65 to 9.22 g CH4 m(-2); and the values ranged 24.6-34.2 and 36.4-52.6 g CH4 m(-2) in the second crop season, respectively. In the first crop season, there were significantly increased 3.1-3.7-fold in methane emission fluxes due to plantation of Indica rice. In comparison of two rice varieties, the Indica rice variety showed a tendency for larger methane emission than the Japonica rice variety in the second crop season. Moreover, ammonium sulfate treatment significantly reduced CH4 emissions by 37-85% emissions compared to potassium nitrate plots. It was concluded that the CH4 emission was markedly dependent on the type of nitrogen fertilizer and rice variety in Taiwan paddy soils.  相似文献   

10.
采用自行研制的生物转鼓过滤器(RDB)反硝化净化NO。结果表明,在实验温度为25~30℃、pH为7.0~7.5、转鼓转速为1.0r/min、空床停留时间(EBRT)为86.40s、营养液用量为5.0L、营养液更换频率为0.2L/d的条件下,RDB在30d内完成挂膜;RDB稳定运行期间,当NO进气质量浓度为90~433mg/m3时,NO去除率维持在42.9%~85.2%,平均去除负荷为10.40g/(m3.h);转鼓转速决定了生物膜表面的更新速率和液膜厚度,当转速为0.5r/min时,NO去除率达到最大值(75.0%);将营养液用量控制在1.3~3.0L较为合理;EBRT是决定反硝化效率的重要因素,当EBRT为345.60s时,NO去除率不受其进气浓度的影响,且去除率高达95%以上,当EBRT为43.20s、NO进气质量浓度从98mg/m3增加到1095mg/m3时,NO去除率从62.5%下降到30.7%,当进气负荷为50.00g/(m3.h)时,NO去除负荷达到最大值(27.50g/(m3.h))。  相似文献   

11.
Portable 24-hr sampling units were used to collect air samples from eight biofilters on four animal feeding operations. The biofilters were located on a dairy, a swine nursery, and two swine finishing farms. Biofilter media characteristics (age, porosity, density, particle size, water absorption capacity, pressure drop) and ammonia (NH3), hydrogen sulfide (H2S), sulfur dioxide (SO2), methane (CH4), and nitrous oxide (N2O) reduction efficiencies of the biofilters were assessed. The deep bed biofilters at the dairy farm, which were in use for a few months, had the most porous media and lowest unit pressure drops. The average media porosity and density were 75% and 180 kg/m3, respectively. Reduction efficiencies of H2S and NH3 (biofilter 1: 64% NH3, 76% H2S; biofilter 2: 53% NH3, 85% H2S) were close to those reported for pilot-scale biofilters. No N2O production was measured at the dairy farm. The highest H2S, SO2, NH3, and CH4 reduction efficiencies were measured from a flat-bed biofilter at the swine nursery farm. However, the highest N2O generation (29.2%) was also measured from this biofilter. This flat-bed biofilter media was dense and had the lowest porosity. A garden sprinkler was used to add water to this biofilter, which may have filled media pores and caused N2O production under anaerobic conditions. Concentrations of H2S and NH3 were determined using the portable 24-hr sampling units and compared to ones measured with a semicontinuous gas sampling system at one farm. Flat-bed biofilters at the swine finishing farms also produced low amounts of N2O. The N2O production rate of the newer media (2 years old) with higher porosity was lower than that of older media (3 years old) (P = 0.042).  相似文献   

12.
常温低基质下磷酸盐对厌氧氨氧化反应的影响   总被引:2,自引:0,他引:2  
采用上向流厌氧氨氧化生物膜滤池反应器,研究了在进水温度(25±1)℃、pH值7.5~7.7、进水NHf—N及NO2--N浓度30-45iiig/L、COD小于10mg/L的条件下磷酸浓度对厌氧氨氧化反应的影响。实验结果表明,当TP〈5mg/L,磷酸盐浓度对厌氧氨氧化反应没有影响;当TP在5~7.5mg/L之间时随着磷酸盐浓度的增高氨氮的去除受到抑制,总氮的去除率随之降低。停止投加磷酸盐后系统处理效能可以快速恢复。  相似文献   

13.
The nitrifying activity and the effect of fertilization with urea and methylene urea were studied in a landfarming site. The site has been operative over 20 years and maintained by heavy nitrogen fertilization. The landfarming soil contained 4-6% (w/w) oil. The nitrate accumulation was 20-50mg NO3-N day(-1)kg(-1) observed after methylene urea fertilization of 889 g Nm(-2). Nitrification ex situ (in laboratory conditions) was 8.8 mg NO3-N day(-1) kg(-1) in the presence of 380 mg kg(-1) NH4+-N. The half-saturation concentration of nitrification was more than 200 mg NH4+-N kg(-1). The results show that nitrification was active in soil with high oil concentration. Urea fertilization of 893 g Nm(-2) caused an increase of soil NH4+-N concentration up to 5500 mg kg(-1) and pH>8.5. This led to inhibition of nitrification, which persisted after NH4+ concentration decreased below 200mg NH4+ kg(-1).  相似文献   

14.
Nitrous oxide flux from landfill leachate-sawdust nitrogenous compost   总被引:4,自引:0,他引:4  
Hui CH  So MK  Lee CM  Chan GY 《Chemosphere》2003,52(9):1547-1551
Composted nitrogenous waste has the potential to produce excessive amounts of nitrous oxide (N2O), a potent greenhouse gas that also contributes to stratospheric ozone depletion. In this laboratory study, sawdust was irrigated with varying amounts of landfill leachate with high NH4+-N content (3950 mg l(-1)). Physicochemical properties, including the amount of N2O produced, were monitored during the composting process over 28 days. A rapid decline in NH4+-N in the first 4 days and increasing NO3--N for 11 days was followed by lower but stabilized levels of available-N, even with repeated leachate irrigation. Less than 0.03% of the leachate-applied N was lost as N2O. Higher leachate applications as much as tripled N2O production, but this represented a lesser proportion overall of the total nitrogen. Addition of glucose to the composting process had no significant effect on N2O production. The derived sawdust-leachate compost supported healthy growth of Sesbania rostrata. It is concluded that compost can be produced from sawdust irrigated with landfill leachate without substantial emission of N2O, although excessive flux of N2O remains about high application rates over longer time periods.  相似文献   

15.
The kinetics of H2S oxidation in a biofilter were evaluated and the reaction rates determined to be first-order at low concentrations (<200 ppm), zero-order at high concentrations (>400 ppm), and fractional-order in the intermediate concentration range for H2S in the inlet waste gas. The overall performance of the biofilter system and changes in compost properties were investigated for 200 days of operation. The compost biofiiter showed good buffering capacities to variations in gas flow rate and pollutant (H2S) loading impacts. Hydrogen sulfide removal efficiencies exceeding 99.9% were consistently observed. System acidification and sulfate accumulation were identified as inhibitors of required biological activity. Routine washing of the compost effectively mitigated these deficiencies. System upset was determined to be caused by compost dry-out or system overloading. Methods were developed to provide for recovery of contaminated filter material.  相似文献   

16.
ABSTRACT

This paper presents results obtained from a performance study on the biotreatment of 1,3-butadiene in an air stream using a reactor that consisted of a two-stage, in-series biotrickling filter connected with a three-stage, in-series biofilter. Slags and pig manure-based media were used as packing materials for the biotrickling filter and the biofilter, respectively. Experimental results indicated that, for the biotrickling filter portion, the butadiene elimination capacities were below 5 g/m3/hr for loadings of less than 25 g/m3/hr, and the butadiene removal efficiency was only around 17%. For the biofilter portion, the elimination capacities ranged from 10 to 107 g/m3/hr for loadings of less than 148 g/m3/hr. The average butadiene removal efficiency was 75–84% for superficial gas velocities of 53–142 m/hr and a loading range of 10–120 g/m3/hr. The elimination capacity approached a maximum of 108 g/m3/hr for a loading of 150 g/m3/hr. The elimination rates of butadiene in both the biotrickling filter and biofilter were mass-transfer controlled for influent butadiene concentrations below about 600 ppm for superficial gas velocities of 29–142 m/hr. The elimination capacity was significantly higher in the biofilter than in the biotrickling filter. This discrepancy may be attributed to the higher mass-transfer coefficient and gas-solid interfacial area offered for transferring the gaseous butadiene in the biofilter.  相似文献   

17.
Prado OJ  Veiga MC  Kennes C 《Chemosphere》2008,70(8):1357-1365
The removal of mixtures of gas-phase pollutants released from formaldehyde- and formaldehyde resin-producing industries was studied in different bioreactor systems. The waste gases contained formaldehyde, methanol, dimethylether and carbon monoxide. The use of a hybrid two-stage bioreactor, composed of a biotrickling filter and a conventional biofilter connected in series, led to very high elimination capacities and removal efficiencies close to 100% for overall pollutant loads exceeding 600g m(-3)h(-1). The presence of low concentrations of dimethylether in the gaseous mixture did not have a significant effect on the removal of formaldehyde or methanol under our operating conditions, although moderate concentrations of these compounds did negatively affect the biodegradation of dimethylether. When a mixture of all four compounds, at concentrations around 100, 100, 50 and 50mg m(-3) for formaldehyde, methanol, carbon monoxide and dimethylether, respectively, was fed to a conventional biofilter, removal efficiencies higher than 80% were obtained for the first three pollutants at empty bed retention time values above 30s. On the other hand, dimethylether was removed to a lower extent, although its reduced environmental impact allows to conclude that these results were satisfactory.  相似文献   

18.
A bench-scale biofilter was evaluated for removing ammonia (NH3) from poultry house exhaust. The biofilter system was equipped with a compost filter to remove NH3 and calcium oxide (CaO) filter to remove carbon dioxide (CO2). Removal of NH3 and CO2 from poultry house exhaust could allow treated air with residual heat to be recirculated back into the poultry house to conserve energy during winter months. Apart from its use as a plant nutrient, NH3 removal from poultry house exhaust could lessen the adverse environmental impacts of NH3 emissions. Ammonia and CO2 were measured daily with gas detector tubes while temperatures in the poultry pen and compost filter were monitored to evaluate the thermal impact of the biofilter on treated air. During the first 37 days of the 54-day study, exhaust air from 33 birds housed in a pen was treated in the biofilter; for the final 17 days, NH3-laden exhaust, obtained by applying urea to the empty pen was treated in the biofilter. The biofilter system provided near-complete attenuation of a maximum short-term NH3 concentration of 73 ppm. During the last 17 days, with a mean influent NH3 concentration of 26 ppm, the biofilter provided 97% attenuation. The CaO filter was effective in attenuating CO2. Compared with a biofilter sized only for NH3 removal, an oversized biofilter would be required to provide supplemental heat to the treated air through exothermic biochemical reactions in the compost. The biofilter could conserve energy in poultry production and capture NH3 for use as plant nutrient. Based on this study, a house for 27,000 broilers would require a compost filter with a volume of approximately 34 m3.  相似文献   

19.
Propylene and butylene are highly reactive volatile organic compounds (HRVOCs) in terms of ground-level ozone formation. This study examined the effectiveness of biofiltration in removing propylene and butylene as separate compounds. Specific objectives were (1) to measure maximum removal efficiencies for propylene and butylene and the corresponding microbial acclimation times, which will be useful in the design of future biofilters for removal of these compounds; (2) to compare removal efficiencies of propylene and butylene for different ratios of compost/hard wood-chip media; and (3) to identify the microorganisms responsible for propylene and butylene degradation. Two laboratory-scale polyvinyl chloride biofilter columns were filled with 28 in. of biofilter media (compost/wood-chip mixtures of 80:20 and 50:50 ratios). Close to 100% removal efficiency was obtained for propylene for inlet concentrations ranging from 2.9 x 10(4) to 6.3 x 10(4) parts per million (ppm) (232-602 g/m3-hr) and for butylene for inlet concentrations ranging from 91 to 643 ppm (1.7-13.6 g/m3-hr). The microbial acclimation period to attain 100% removal efficiency was 12-13 weeks for both compounds. The lack of similar microbial species in the fresh and used media likely accounts for the long acclimation time required. Both ratios of compost/wood chips (80:20 and 50:50) gave similar results. During the testing, media pH increased slightly from 7.1 to 7.5-7.7. None of the species in the used media that treated butylene were the same as those in the used media that treated propylene, indicating that different microbes are adept at degrading the two compounds.  相似文献   

20.
Biofiltration of gasoline vapor by compost media   总被引:2,自引:0,他引:2  
Gasoline vapor was treated using a compost biofilter operated in upflow mode over 4 months. The gas velocity was 6 m/h, yielding an empty bed retention time (EBRT) of 10 min. Benzene, toluene, ethylbenzene and xylene (BTEX) and total petroleum hydrocarbon (TPH) removal efficiencies remained fairly stable approximately 15 days after biofilter start-up. The average removal efficiencies of TPH and BTEX were 80 and 85%, respectively, during 4 months of stable operation. Biodegradation portions of the treated TPH and BTEX were 60 and 64%, respectively. When the influent concentration of TPH was less than 7800 mg TPH/m3, approximately 50% of TPH in the gas stream was removed in the lower half of the biofilter. When the influent concentration of BTEX was less than 720 mg BTEX/m3, over 75% of BTEX in the gas stream was removed in the lower half of the biofilter. Benzene removal efficiency was the lowest among BTEX. A pressure drop could not be detected over a 1-m bed height at a gas velocity of 6 m/h after approximately 4 months of operation. Results demonstrated that BTEX in gasoline vapor could be treated effectively using a compost biofilter.  相似文献   