首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
ABSTRACT

The exhaust emissions of 17 polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) were investigated in two spark-ignition light-duty vehicles, one gasohol-fueled and a flexible-fuel one fueled with hydrated ethanol. Gasohol is a mixture of gasoline and 22% ethanol. The influence of fuel type and quality, lubricant oil type, and use of fuel additives on the formation of these compounds was tested using standardized U.S. Federal Test Procedure (FTP)-75 cycle tests. The sampling of the PCDD/Fs followed the recommendations of a modified U.S. Environmental Protection Agency (EPA) Method 23 (http://www.epa.gov/ttn/emc/promgate/m-23.pdf) and the analysis basically followed the U.S. EPA Method 8290 (http://www.epa.gov/osw/hazard/testmethods/sw846/pdfs/8290a.pdf). Results showed that emission factors of PCDD/Fs for the gasohol vehicle varied from undetected to 0.068 pg international toxic equivalency (I-TEQ) km?1 (average of 0.0294 pg I-TEQ km?1), whereas in the ethanol vehicle they varied from 0.004 to 0.157 pg (I-TEQ) km?1 (average of 0.031 pg I-TEQ km?1). In the gasohol-powered vehicle, the use of fuel additive diminished the emission of Octachlorodibenzo-p-dioxin (OCDD) significantly, whereas in the ethanol vehicle no significant associations were observed between the investigated variables and the emissions.

IMPLICATIONS The objective of this work was to analyze differences in emissions from a traditional fossil fuel (gasoline) and an alternative renewable fuel (ethanol from sugarcane), and the influence of fuel additives and lubricant oils on the formation of chlorinated dioxins and furans in spark-ignition light-duty gasohol and ethanol vehicles. Renewable fuels are very important in terms of climate change but the risk to the population's health must not increase. Thus the results of this work could help in the development of environmental impact studies as well as orienting policy-makers in formulating strategies for air pollution control.  相似文献   

2.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

3.
Measurements of the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were made in ambient air, ash, and soil impacted by the open burning of wax apple and rice straw residues. Measurements showed that the mean PCDD/F concentration (0.458 pg I-TEQ/Nm3; international toxicity equivalence) in air at two wax apple orchards during open burning increased markedly, -8.1 times higher than that (0.057 pg I-TEQ/Nm3); before open burning. In addition, the mean PCDD/F concentration (0.409 pg I-TEQ/Nm3) in ambient air at a rice straw field was 4.6 times higher than that (0.089 pg I-TEQ/Nm3) before open burning. After burning the residues of wax apple stubble and rice straw, the contents of PCDD/F in ashes were 1.393 and 1.568 ng I-TEQ/kg-ash, respectively, and the contents of PCDD/F in soil were 2.258 and 2.890 ng I-TEQ/kg-soil, respectively. Therefore, the turnover of soil with the ash after open burning over years will result in the accumulation of PCDD/Fs in farm soils.  相似文献   

4.
Dyke PH  Sutton M  Wood D  Marshall J 《Chemosphere》2007,67(7):1275-1286
This paper reports on an intensive study into releases of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated furans (PCDF) and polychlorinated biphenyls (PCB) from a diesel engine and the analysis of PCDD/F and PCB in crankcase lubricating oil. Experimental conditions were set and carefully controlled in order to maximize the possible impact of, and our ability to measure the effect of, changes in the levels of chlorine in the lubricant. Emissions to air were measured using modified EPA methods following the principles of the European EN 1948 standards. A series of 40 experimental runs were completed using three reference lubricants formulated to have three levels of chlorine present as a residual component (at levels of 12, 131 and 259 mg kg(-1) or ppm). The engine was run with and without the diesel oxidation catalyst. All lubricants were realistic oils and the use of unrealistic additives or doping of components - particularly chlorine - in the fuel and lubricant was carefully avoided. Analysis of fuel and lubricant (before and after testing) samples required strenuous attention to achieve acceptable recoveries and showed non-detectable levels of PCB and PCDD/F at a detection limit of around 1.5 ng I-TEQ kg(-1) (ppt), indistinguishable from the laboratory blank. The testing demonstrated the need for extreme care to be taken in developing measurement methods that are sufficiently sensitive for measuring chlorine content of fluids and PCDD/F in oils, the latter being particularly challenging. Mean emissions of PCDD/F with the diesel oxidation catalyst in place were 23 pg I-TEQ l(-1) of fuel and with the diesel oxidation catalyst removed 97 pg I-TEQ l(-1) of fuel. The results of this testing showed that the emissions of PCDD/F were greatly reduced by the presence of a diesel oxidation catalyst in the exhaust, a finding that has not been explicitly tested in previous work. They also show that emissions from the engine were not controlled by the level of chlorine in the lubricant and that emissions did not change in response to a much greater step change in the total chlorine entering the combustion chamber due to a change in the level of chlorine in the fuel. Emissions when the engine was configured with a diesel oxidation catalyst showed a consistent pattern that appears to be unique in the experience of the authors.  相似文献   

5.
Levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) in both air and soil samples were measured at three different sites in Italy, in proximity to three municipal solid waste incinerators (MSWIs) to determine baseline contamination and the contributory role of incinerator emissions. At the first site, located in an agricultural, cattle-breeding, typically flattish area of the Po Valley, the dioxin concentrations had already been measured before the start-up of the new MSWI. These dioxin concentrations were then again measured after two years of continual operation of the incinerator. Despite the presence of the plant, the PCDD/Fs concentrations appear not to have been affected and were found to be in a range of 22-125 fg I-TEQ m(-3) in the air samples and 0.7-1.5 pg I-TEQ g(-1) in the soil samples. The second site is located in an industrial district of the Veneto Region, in the surroundings of an old MSWI that is not equipped with Best Available Technology (BAT) dioxin removal system. The PCDD/Fs concentrations in the air samples were between 144 and 337 fg I-TEQ m(-3). This is a typical range of values for industrial areas, while the soil samples showed contamination levels between 1.1 and 1.4 pg I-TEQ g(-1). The third site lies in the Adige Valley, near a MSWI that has been equipped with BAT for flue gas cleaning. The observed values ranged from 10 to 67 fg I-TEQ m(-3) for the air samples and 0.08-1.2 pg I-TEQ g(-1) for the soil samples. The contributory factors of the varying characteristics of the different areas together with the types of technology adopted at each MSWI plant are discussed. The PCDD/Fs levels are subsequently compared with established values from previous studies.  相似文献   

6.
Yu BW  Jin GZ  Moon YH  Kim MK  Kyoung JD  Chang YS 《Chemosphere》2006,62(3):494-501
The metallurgy industry and municipal waste incinerators are considered the main sources of polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) in many countries. This study investigated the emission factors and total emissions of PCDD/Fs and dioxin-like polychlorinated biphenyls (PCBs) emitted from metallurgy industries (including ferrous and nonferrous foundries) in Korea. The toxic equivalency (TEQ) emission factor of PCDD/Fs was the highest for secondary copper production, at 24451 ng I-TEQ/ton. The total estimated emissions of PCDD/Fs from these sources were 35.259 g I-TEQ/yr, comprising 0.088 g I-TEQ/yr from ferrous foundries, 31.713 g I-TEQ/yr from copper production, 1.716 g I-TEQ/yr from lead production, 0.111 g I-TEQ/yr from zinc production, and 1.631 g I-TEQ/yr from aluminum production. The total estimated annual amounts of dioxin-like PCBs emitted from these sources were 13.260 g WHO-TEQ/yr, comprising 0.014 g WHO-TEQ/yr from ferrous foundries, 12.675 g WHO-TEQ/yr from copper production, 0.170 g WHO-TEQ/yr from lead production, 0.017 g WHO-TEQ/yr from zinc production, and 0.384 g WHO-TEQ/yr from aluminum production. The highest emission factor was found for secondary copper smelting, at 9770 ng WHO-TEQ/ton.  相似文献   

7.
Lee SJ  Choi SD  Jin GZ  Oh JE  Chang YS  Shin SK 《Chemosphere》2007,68(5):856-863
Municipal solid waste incinerators (MSWIs) have been shown to be important sources of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). The emission of PCDD/Fs by MSWIs is a controversial subject in human health risk assessment. In this study the effect of a MSWI on a residential area was assessed before and after the installation of an additional treatment system for flue gas. This additional treatment system resulted in a dramatic decrease in PCDD/F concentrations in stack flue gas samples by 99.98%, while the concentrations in air decreased by approximately 50% (36,500 and 0.75 pg I-TEQ m(-3) for air in 1999; 3.5 and 0.38 pg I-TEQ m(-3) in 2002; 1.6 and 0.076 pg I-TEQ m(-3) in 2005 for stack gas and air, respectively). Considering the congener distributions of PCDD/Fs between stack flue gas and air samples, the study area seemed to have been contaminated by other urban sources as well as the MSWI. ISC3 model results support the conclusion that this incinerator became only a minor contributor to the study area after installation of the supplementary systems. This resulted from both proper MSWI operation using modern technology and additional sources of contaminants in this region. Finally, PCDD/F uptake by humans through inhalation of contaminated air was estimated. Assuming that inhalation exposure contributes 10% of total exposure, total exposure was lower than WHO guidelines. These results confirm that proper operation and maintenance of the incinerator led to a reduction in emissions and potential health impacts of PCDD/Fs.  相似文献   

8.
In April 1996 and 1998, the concentrations of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in 40 herbage samples collected in the neighborhood of a hazardous waste incinerator (HWI) under construction in Constanti (Catalonia, Spain). In April 2000, 20 months after the HWI began operating, herbage samples were again collected at the same sampling points in which samples had been taken in the previous surveys. PCDD/F concentrations ranged between 0.13 and 0.65 ng I-TEQ/kg (dry matter), with a median and mean values of 0.29 and 0.32 ng I-TEQ/kg (dry matter), respectively. The results were compared with those obtained in the 1996 (median, 0.53 ng I-TEQ/kg; mean, 0.61 ng I-TEQ/kg) and the 1998 (median, 0.23 ng I-TEQ/kg; mean, 0.31 ng I-TEQ/kg) surveys. While in the period 1996-1998 a significant decrease (49%, P < 0.001) in the mean PCDD/F levels was noted, in the period 1998-2000 an increase of 3% (P > 0.05) was found in the concentrations of PCDD/Fs. The analysis of the results suggests two potential hypotheses: either the emissions of PCDD/Fs from the HWI are not negligible, or the current PCDD/F emissions from other sources near the HWI remained at similar levels to those reached in 1998. Anyhow, an exhaustive evaluation of the present data shows an absence of notable PCDD/F contamination by the HWI in the area under its direct influence. It seems also probable that the decline in the atmospheric levels of PCDD/Fs due other emission sources of PCDD/Fs in this area is currently stopped.  相似文献   

9.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

10.
Concentrations of 17 toxic 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) have been determined in pooled samples of breast milk from 15 mothers living in two residential areas (Tarragona downtown and an industrial area) in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (southern Catalonia, Spain). PCDD/Fs in human milk samples ranged between 5.9 and 17.1 pg I-TEQ/g fat (162-498 pg I-TEQ/l), with a mean value of 11.8 pg I-TEQ/g fat (310.8 pg I-TEQ/l). The percentages of fat ranged between 1.53 and 3.52. Although PCDD/F levels in milk from mothers living in the industrial area were found to be slightly higher than those observed in women living Tarragona downtown, most differences did not reach the level of statistical significance. In general terms, PCDD/F concentrations in human milk (pooled) samples of mothers living in the area of Tarragona are similar or lower than those previously reported for most industrialized countries.  相似文献   

11.
Most polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the atmosphere are bound to particles which are suspended in the atmosphere, and eventually settle on soil, vegetation, water bodies or other receptors in the environment. Monitoring atmospheric deposition fluxes (dry/wet) is important in tracing the environmental fate and behavior of PCDD/Fs. PCDD/F depositions were collected via an automated PCDD/F ambient sampler and traditional cylindrical vessels, respectively, from April 2007 to February 2008. The automated PCDD/F ambient sampler used in this study can prevent both re-suspension and photo degradation of the PCDD/Fs collected and effectively separates the PCDD/F samples into dry and wet contributions. The results indicated that the ambient PCDD/F concentrations collected using the PS-1 sampler ranged from 0.02 pg I-TEQ/m3 to 0.16 pg I-TEQ/m3 in Northern Taiwan. The results also indicated that the PCDD/F deposition flux collected using the automated PCDD/F sampler (17.5 pg I-TEQ/m2 d to 25.8 pg I-TEQ/m2 d) was significantly higher than that sampled with the cylindrical vessels (2.0 pg I-TEQ/m2 d to 9.9 pg I-TEQ/m2 d). The difference was attributed to the fact that part of the PCDD/F depositions collected using the traditional cylindrical vessels had undergone photo degradation and evaporation. In addition, the wet deposition flux of PCDD/Fs (39.4 pg I-TEQ/m2 rainy day to 228 pg I-TEQ/m2 rainy day) observed in this study was significantly higher than the dry deposition flux (12.3 pg I-TEQ/m2 sunny day to 16.7 pg I-TEQ/m2 sunny day). These results demonstrated that wet deposition is the major PCDD/F removal mechanism in the atmosphere.  相似文献   

12.
Annual emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) from open burning of crop residues in each province of China mainland between 1997 and 2004 were estimated to be ranged from 1.38x10(3) to 1.52x10(3) g I-TEQ/yr, with the average of 1.50+/-0.08x10(3) g I-TEQ/yr, which contributed to approximately 10% approximately 20% of the total emissions in China. The PCDD/F emissions mainly occurred in the largest crop-producing provinces, especially in those of higher economic levels. The major sources of PCDD/F emissions from open burning in China were found to be cereal residues (i.e. rice, wheat, and corn), which accounted about 70% of the total emissions. Moreover, the first-order one-variable grey differential equation model (GM (1,1) model) for annual emissions of PCDD/Fs was established based on grey system theory. The GM (1,1) model was proved to be robust to predict the annual PCDD/F emissions from crop residue field burning in forthcoming years.  相似文献   

13.
The results of an assessment study of both industrial and non-industrial dioxin and furan (PCDD/Fs) emissions in the Lombardy Region (Italy) are outlined below. The main data source refer to 1997, and are compiled from the Lombardy Emissions Inventory (developed under the framework of the Regional Air Quality Plan) together with documented emissions factors available. Due to the uncertain nature of the emissions assessment, results are provided as a most probable value within a given range. Total PCDD/Fs emissions in Lombardy average 33 g I-TEQ y(-1), ranging from minimum 13 g I-TEQ y(-1) to maximum 88 g I-TEQ y(-1). The main PCDD/Fs sources are waste incineration, electric arc furnace for steel production, vehicle diesel combustion and residential wood combustion. Incineration emission factors are expected to decrease over the period 2005-2010, in compliance with legal requirements. This will prioritize control over the remaining main PCDD/Fs contributors. Due to limited information available concerning this data, the accuracy of which is uncertain, further research is needed to evaluate the future role of these sources.  相似文献   

14.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

15.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

16.
Particle-bound polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and polychlorinated biphenyls (PCBs) were monitored at two sites in northern Greece for an eight-month period in 1999. PCDD/F concentrations were close to the lower end of reported values worldwide. Excepting a few cases, the PCDD/Fs homologue profile was stable. The gaseous PCDD/F fractions calculated were found to account for a small percentage of the total concentrations (<2% for OCDD/Fs and HpCDD/Fs, while 30-35% for TCDFs). Particle-bound PCBs were also found at low concentrations which, however, were higher at the urban site. Calculations of the dry deposition of particulate PCDD/ Fs and PCBs gave mean values of 0.52 and 0.59 pg I-TEQ/m2/day of PCDD/Fs, while 242 and 74 pg/m2/day of sigmaPCBs for the urban and the semirural areas respectively. An anticorrelation of PCDD/F concentrations with ambient temperature was derived particularly for the lower chlorinated congeners. A weak association with winds of western and southern origin was also observed. Factor analysis and literature source profiles were employed to identify possible emission sources. It was appeared that the PCDD/F compositional pattern of TSP is influenced by mixed sources the most prominent being uncontrolled fires and car exhausts.  相似文献   

17.
Hu SW  ChangChien GP  Chan CC 《Chemosphere》2004,55(4):611-620
This study monitored ambient air concentrations of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) in three municipal waste incineration plants. Blood PCDD/Fs levels of 133 workers randomly selected from these plants were also measured. The associations between workers' blood PCDD/Fs concentrations and occupational exposures to PCDD/Fs were assessed. Means of air PCDD/Fs levels ranged from 0.08 to 3.01 pg/m3 in international toxic equivalents (I-TEQ). The geometric means of blood PCDD/Fs concentrations were 14.6, 15.8, 19.1 pg/g lipid in World Health Organization (WHO) TEQ, respectively, for workers from three plants. Air levels of total I-TEQ and all congeners, except 2,3,7,8-tetrachlorinated dibenzo-p-dioxin (TeCDD) and 1,2,3,4,7,8,9-heptachlorinated dibenzofuran (HpCDF), were significantly higher in plant B. However, blood concentrations of 2,3,7,8-TeCDD, 1,2,3,7,8-PeCDD, 2,3,7,8-TeCDF, 1,2,3,7,8-PeCDF and 1,2,3,4,7,8,9-HpCDF were significantly elevated in plant C workers. Although job contents, duration of employment and time spent in certain location were significantly different among incineration plants, they were not significantly associated with blood concentrations of any congener. Furthermore, results of the multiple regression analysis that assessed important occupational factors simultaneously and adjusted for potential confounders, showed significant associations between four congeners and incineration plant or job contents. However, the results were limited by small R-squares of the regression models. In conclusion, blood concentrations of several PCDD/Fs congeners were significantly different among three incineration plants. The differences were not explained by the discrepancy in job contents, duration of employment, and time activity in these plants.  相似文献   

18.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

19.
The production of cement in China is accompanied by various emissions, such as fine particulate matter, heavy metals, nitrogen oxides, sulfur oxides, carbon dioxide…. Moreover, cement kiln presents a potential health risk to its surroundings, linking to emissions of persistent organic pollutants (POPs), such as polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), in brief dioxins. Flue gas samples were collected from five typical cement kilns during twelve runs and were used to evaluate the levels and distribution of PCDD/Fs in the emissions from cement kilns. The PCDD/Fs concentrations (136 congeners) and I-TEQ values ranged from 2.3 to >40 ng/m3 and 9.3?~?90.8?×?10?3 ng I-TEQ/m3, respectively, which were lower than the emission standard in China (0.1 ng I-TEQ/m3). In weight units, the dominant congeners were OCDD, 1,2,3,4,6,7,8-HpCDF, and OCDF; 2,3,4,7,8-PeCDF is the largest contributor (36–66 %) to the total I-TEQ value of twelve runs. HxCDF and TCDF were the first two most abundant homologue groups (12–85 and 4–52 %), and the homologue concentration decreased with rising chlorine number for PCDDs. In addition, there was no marked difference in homologue profiles when solid wastes (refuse-derived fuel and municipal solid waste) and hazardous wastes (DDT and POPs) were combusted as supplemental fuels. The use of various supplemental fuels had no obvious effect on the fingerprint of PCDD/F homologues. Moreover, there was no significant difference in levels of PCDD/Fs emission due to the diversity of production capacity, which were consistent with reported previously. Air pollution control device had effect on the homologue profiles, and cement system with electrostatic precipitators (ESP) had more fractions of octachloro congeners to the total.  相似文献   

20.
A survey to estimate the polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) emissions of Spanish hot dip galvanising sector was carried out during 2002. This investigation is the first presenting Spanish experimental data related to this industrial sector. Three different matrices: flue gas, ash and filter dust were tested to quantify the PCDD/Fs generated during the galvanising process. The organic source of PCDD/F formation could be from the insufficient degreasing o from inhibitors or additives used in the pickling steps such as quinoline, isoquinoline, 8-methylquinoline or polyether phosphoric acid. Low levels PCDD/Fs were achieved in air emissions when air control devices are used. On the contrary, filter dusts are highly contaminated; indicating that the absence of air control devices would increase the risk of fugitive emissions. Homologue profiles and Principal Component Analysis demonstrate there are differences in the formation mechanisms in the bath zone (ashes) compared to the stack location (filter dusts and air emissions), related to the de novo synthesis and reaction time. The annual PCDD/F emission to the atmosphere for this sector during 2002 has been estimated in 0.023g I-TEQ. The emission factor of plants with air control devices has been calculated at 0.030microg I-TEQ/ton of galvanised steel.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号