首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Elevated concentrations of nitrogen dioxide (NO2) are produced in the home by the use of unvented gas appliances. In studies on potential health effects of Indoor exposure to NO2, exposure has mostly been estimated from the presence or absence of sources like gas cookers in the home. This leads to misclassification of exposure, as NO2 concentrations in the home depend also on source use, ventilation habits, time budgets, etc. The availability of cheap, passive monitoring devices has made it possible to measure Indoor concentrations of NO2 directly in health effects studies, albeit with averaging times of one to several days. So far, it has not been evaluated whether this increases the sensitivity of a study to detect health effects of NO2. In this paper, a comparison is made between NO2 sources and weekly average indoor NO2 measurements, as predictors of pulmonary function in a study among children aged 6–12 years.

The relationship between exposure and lung functions was found to be generally non-significant in this study. The results further suggested that in this study, measuring Indoor NO2 concentrations with passive monitors offered no advantage over the simple use of source presence as exposure variable.  相似文献   

2.
Indoor and outdoor NO2 concentrations were measured and compared with simultaneously measured personal exposures of 57 office workers in Brisbane, Australia. House characteristics and activity patterns were used to determine the impacts of these factors on personal exposure. Indoor NO2 levels and the presence of a gas range in the home were significantly associated with personal exposure. The time-weighted average of personal exposure was estimated using NO2 measurements in indoor home, indoor workplace, and outdoor home levels. The estimated personal exposures were closely correlated, but they significantly underestimated the measured personal exposures. Multiple regression analysis using other nonmeasured microenvironments indicated the importance of transportation in personal exposure models. The contribution of transportation to the error of prediction of personal exposure was confirmed in the regression analysis using the multinational study database.  相似文献   

3.
Determination of volatile organic compounds (VOCs) formed one part of the EU-EXPOLIS project in which the exposure of European urban populations to particles and gaseous pollutants was studied. The EXPOLIS study concentrated on 30 target VOCs selected on the basis of environmental and health significance and usability of the compounds as markers of pollution sources. In the project, 201 subjects in Helsinki, 50 in Athens, 50 in Basel, 50 in Milan and, 50 in Oxford and 50 in Prague were selected for the final exposure sample. The microenvironmental and personal exposure concentrations of VOCs were the lowest in Helsinki and Basel, while the highest concentrations were measured in Athens and Milan; Oxford and Prague were in between. In all cities, home indoor air was the most significant exposure agent. Workplace indoor air concentrations measured in this study were generally lower than the home indoor concentrations and home outdoor air played a minor role as an exposure agent. When estimating the measured personal exposure concentrations using the measured concentrations and time fractions spent at home indoors, at home outdoors, and at the workplace, it could be concluded that these three microenvironments do not fully explain the personal exposure. Other important sources for personal exposure must be encountered, the most important being traffic/transportation and other indoor environments not measured in this study.  相似文献   

4.
In a field study of 302 residences, the indoor air contaminant concentrations associated with the use of unvented kerosene space heaters and gas cooking stoves were measured. For each residence, 2-week average NO2 levels were recorded outdoors and in three rooms using diffusion-type passive monitors. Data were obtained on NO2 sources, the level of use of these sources and on building characteristics from an initial questionnaire, a bi-weekly telephone interview, daily diaries and from assessors' records. The methodology employed in the field study is evaluated in terms of a multivariate model which predicts variations in NO2 levels in the residences as a function of the existence and reported use of sources. The source use parameters were found to explain over 60 % of the variation in residential indoor NO2 levels. The levels of specification needed for other independent variables (infiltration, removal rates, etc.) and the source use terms in the predictive model are presented and discussed.  相似文献   

5.
High CO and NO2 concentrations have been documented in homes with unvented combustion appliances, such as natural gas fireplaces. In addition, polycyclic aromatic hydrocarbons (PAH) are emitted from incomplete natural gas combustion. The acute health risks of CO and NO2 exposure have been well established for the general population and for certain high-risk groups, including infants, the elderly, and people with heart disease or asthma. Health effects from PAH exposure are less well known, but may include increased risk of cancer. We monitored CO emissions during the operation of unvented natural gas fireplaces in two residences in Boulder, CO, at various times between 1997 and 2000. During 1999, we expanded our tests to include measurements of NO2 and PAH. Results show significant pollutant accumulation indoors when the fireplaces were used for extended periods of time. In one case, CO concentrations greater than 100 ppm accumulated in under 2 hr of operation; a person at rest exposed for 10 hr to this environment would get a mild case of CO poisoning with an estimated 10% carboxyhemoglobin level. Appreciable NO2 concentrations were also detected, with a 4-hr time average reaching 0.36 ppm. Similar time-average total PAH concentrations reached 35 ng/m3. The results of this study provide preliminary insights to potential indoor air quality problems in homes operating unvented natural gas fireplaces in Boulder.  相似文献   

6.
Sources and concentrations of indoor nitrogen dioxide in Barcelona, Spain   总被引:1,自引:0,他引:1  
Sources and concentrations of indoor nitrogen dioxide (NO2) were examined in Barcelona, Spain, during 1996-1999. A total of 340 dwellings of infants participating in a hospital-based cohort study were selected from different areas of the city. Passive filter badges were used for indoor NO2 measurement over 7-30 days. Dwelling inhabitants completed a questionnaire on housing characteristics and smoking habits. Data on outdoor NO2 concentrations were available for the entire period of the study in the areas of the city where indoor concentrations were determined. Bivariate analysis was performed to investigate relationships between indoor NO2 concentrations on one hand and outdoor NO2 concentrations, housing, and occupant characteristics on the other. Stepwise multiple linear regression was performed with variables that were found to have a significant bivariate relationship. Indoor NO2 mean values ranged between 23.57 ppb in 1996 and 27.02 ppb in 1999, with the highest yearly value of 27.82 ppb in 1997. In the same time period, mean outdoor NO2 concentration ranged between 25.26 and 25.78 ppb with a peak of 30.5 ppb in 1998. Multiple regression analysis showed that principal sources of indoor NO2 concentrations were the use of a gas cooker, the absence of an extractor fan when cooking, and cigarette smoking. The absence of central heating was also associated with higher NO2 concentrations. Finally, each ppb increase in outdoor NO2 was associated with a 1% increase in indoor concentrations.  相似文献   

7.
We conducted a multi-pollutant exposure study in Baltimore, MD, in which 15 non-smoking older adult subjects (> 64 years old) wore a multi-pollutant sampler for 12 days during the summer of 1998 and the winter of 1999. The sampler measured simultaneous 24-hr integrated personal exposures to PM2.5, PM10, SO4(2-), O3, NO2, SO2, and exhaust-related VOCs. Results of this study showed that longitudinal associations between ambient PM2.5 concentrations and corresponding personal exposures tended to be high in the summer (median Spearman's r = 0.74) and low in the winter (median Spearman's r = 0.25). Indoor ventilation was an important determinant of personal PM2.5 exposures and resulting personal-ambient associations. Associations between personal PM2.5 exposures and corresponding ambient concentrations were strongest for well-ventilated indoor environments and decreased with ventilation. This decrease was attributed to the increasing influence of indoor PM2.5 sources. Evidence for this was provided by SO4(2-) measurements, which can be thought of as a tracer for ambient PM2.5. For SO4(2-), personal-ambient associations were strong even in poorly ventilated indoor environments, suggesting that personal exposures to PM2.5 of ambient origin are strongly associated with corresponding ambient concentrations. The results also indicated that the contribution of indoor PM2.5 sources to personal PM2.5 exposures was lowest when individuals spent the majority of their time in well-ventilated indoor environments. Results also indicate that the potential for confounding by PM2.5 co-pollutants is limited, despite significant correlations among ambient pollutant concentrations. In contrast to ambient concentrations, PM2.5 exposures were not significantly correlated with personal exposures to PM2.5-10, PM2.5 of non-ambient origin, O3, NO2, and SO2. Since a confounder must be associated with the exposure of interest, these results provide evidence that the effects observed in the PM2.5 epidemiologic studies are unlikely to be due to confounding by the PM2.5 co-pollutants measured in this study.  相似文献   

8.
Modeling exposure to particulate matter   总被引:2,自引:0,他引:2  
Exposure assessment, a component of risk assessment, links sources of pollution with health effects. Exposure models are scientific tools used to gain insights into the processes affecting exposure assessment. The purpose of this paper is to review the process and methodology of estimating inhalation exposure to particulate matter (PM) using various types of models. Three types of models are discussed in the paper. Indirect type of models are physical models that employ inventories of outdoor and indoor sources and their emission rates to identify major sources contributing to exposure to PM, and use fate and transport and indoor air quality models to estimate PM concentrations at receptor sites. PM concentrations and time spent by a subject at each receptor site are input variables to the conventional exposure model that estimates the desired exposure levels. Direct type models use measured exposure or exposure concentrations in conjunction with information obtained from questionnaires to formulate exposure regression models. Stochastic models use exposure measurements, estimates can also be used, to formulate exposure population distributions and investigate associated uncertainty and variability. Since models developed using databases from western countries are not necessarily applicable in developing countries, the difference in requirements among western and developing countries is highlighted in the paper. Employment of exposure modeling methods in developing countries requires development of local information. Such information includes local outdoor and indoor source inventories, local or regional meteorological conditions, adjustment of indoor models to reflect local building construction conditions, and use of questionnaires to obtain local time budget and activity patterns of the subject population.  相似文献   

9.
Nitrogen dioxide is a ubiquitous pollutant in urban areas. Indoor NO2 concentrations are influenced by penetration of outdoor concentrations and by indoor sources. The objectives of this study were to evaluate personal exposure to NO2, taking into account human time-activity patterns in four Mexican cities. Passive filter badges were used for indoor, outdoor, and personal NO2 measurements over 48 hr and indoor workplace measurements over 16 hr. Volunteers completed a questionnaire on exposure factors and a time-activity diary during the sample period. An unpaired t test, an analysis of variance (ANOVA), and a linear regression were performed to compare differences among cities and mean personal NO2 concentrations involving housing characteristics, as well as to determine which variables predicted the personal NO2 concentration. Sampling periods were in April, May, and June 1996 in Mexico City, Guadalajara, Cuernavaca, and Monterrey. All 122 volunteers in the study were working adults, with a mean age of 34 (SD +/- 7.38); 64% were female, and the majority worked in public offices and universities. The highest NO2 concentrations were found in Mexico City (36 ppb for outdoor, 57 ppb for indoor, and 39 ppb for personal concentration) and the lowest in Monterrey (19 ppb for outdoor, 24 ppb for indoor, and 24 ppb for personal concentration). Significant differences in NO2 concentrations were found among the cities in different microenvironments. During the sampling period, volunteers spent 85% of their time indoors. The highest personal NO2 concentration was found when volunteers kept their windows closed (p = 0.03). In the regression model adjusted by city and gender, the best predictors of personal NO2 concentration were outdoor levels and time spent outdoors (R2 = 0.68). These findings suggest that outdoor NO2 concentrations were an important influence on the personal exposure to NO2, due to the specific characteristics and personal behavior of the people in these Mexican cities.  相似文献   

10.
Traffic is a major source of air pollutants in urban environments, and exposure to these pollutants may be associated with adverse health effects. However, inconsistencies in observational epidemiological studies may be caused by differential measurement errors in various approaches in assessing exposure.We aimed to evaluate a simple method for assessing outdoor air pollutant concentrations in Oslo, Norway, through a land-use regression method.Samples of nitrogen oxides (NOx) were collected in two different weeks using Ogawa passive diffusion samplers simultaneously at 80 locations across Oslo. Independent variables used in subsequent regression models as predictors of the pollutants were derived using the Arc 9 geographic information system (GIS) software. Indicators of land use, traffic, population density, and physical geography were tested.The final regression model yielded an adjusted coefficient of determination (R2) of 0.77 for nitrogen dioxide (NO2), 0.66 for nitric oxide (NO), and 0.73 for NOx.The results suggest that a good predictive exposure model can be derived from this approach, which can be used to estimate long-term small-area variation in concentrations for individual exposure assessment in epidemiological studies in a highly cost-effective way. These small-area variations in traffic pollution are important since they may have associations with health effects.  相似文献   

11.
ABSTRACT

Indoor and outdoor NO2 concentrations were measured and compared with simultaneously measured personal exposures of 57 office workers in Brisbane, Australia. House characteristics and activity patterns were used to determine the impacts of these factors on personal exposure. Indoor NO2 levels and the presence of a gas range in the home were significantly associated with personal exposure. The time-weighted average of personal exposure was estimated using NO2 measurements in indoor home, indoor workplace, and outdoor home levels. The estimated personal exposures were closely correlated, but they significantly underestimated the measured personal exposures. Multiple regression analysis using other nonmeasured microenvironments indicated the importance of transportation in personal exposure models. The contribution of transportation to the error of prediction of personal exposure was confirmed in the regression analysis using the multinational study database.  相似文献   

12.
In preparation for a prospective study of the relationship of residential nitrogen dioxide exposure and respiratory infections in infants, we conducted a pilot study to assess NO2 concentrations in a sample of homes in Albuquerque, New Mexico. The methods used to characterize concentrations are described. Three locations in 144 homes were monitored with passive diffusion samplers for two two-week cycles during November and December 1984. Two-week average NO2 concentrations in the activity room ranged from 2.0 to 168.7 ppb. NO2 concentrations in the activity room and the infant’s bedroom were fivefold higher in homes with gas stoves than in homes with electric stoves. Sixty-four percent of homes with gas stoves had activity room concentrations that exceeded the highest outdoor concentration. Multiple regression models Indicated that the outdoor concentration, use of a gas stove, particularly one with pilot lights, presence of a gas dryer in the living area, and use of a floor or wall furnace contributed to NO2 concentrations. Use of a toaster or microwave oven in a house with a gas stove reduced NO2 concentrations. The results of this study demonstrate a broad range of NO2 concentrations in Albuquerque. We conclude with suggestions for an exposure assessment strategy that would be valid and feasible in the context of a large epidemiologic study of the health effects of NO2.  相似文献   

13.
During the last two decades there has been increasing concern within the scientific community over the effects of indoor air quality on health. Changes in building design devised to improve energy efficiency have meant that modern homes and offices are frequently more airtight than older structures. Furthermore, advances in construction technology have caused a much greater use of synthetic building materials. Whilst these improvements have led to more comfortable buildings with lower running costs, they also provide indoor environments in which contaminants are readily produced and may build up to much higher concentrations than are found outside. This article reviews our current understanding of the relationship between indoor air pollution and health. Indoor pollutants can emanate from a range of sources. The health impacts from indoor exposure to combustion products from heating, cooking, and the smoking of tobacco are examined. Also discussed are the symptoms associated with pollutants emitted from building materials. Of particular importance might be substances known as volatile organic compounds (VOCs), which arise from sources including paints, varnishes, solvents, and preservatives. Furthermore, if the structure of a building begins to deteriorate, exposure to asbestos may be an important risk factor for the chronic respiratory disease mesothelioma. The health effects of inhaled biological particles can be significant, as a large variety of biological materials are present in indoor environments. Their role in inducing illness through immune mechanisms, infectious processes, and direct toxicity is considered. Outdoor sources can be the main contributors to indoor concentrations of some contaminants. Of particular significance is Radon, the radioactive gas that arises from outside, yet only presents a serious health risk when found inside buildings. Radon and its decay products are now recognised as important indoor pollutants, and their effects are explored. This review also considers the phenomenon that has become known as Sick Building Syndrome (SBS), where the occupants of certain affected buildings repeatedly describe a complex range of vague and often subjective health complaints. These are often attributed to poor air quality. However, many cases of SBS provide a valuable insight into the problems faced by investigators attempting to establish causality. We know much less about the health risks from indoor air pollution than we do about those attributable to the contamination of outdoor air. This imbalance must be redressed by the provision of adequate funding, and the development of a strong commitment to action within both the public and private sectors. It is clear that meeting the challenges and resolving the uncertainties associated with air quality problems in the indoor environment will be a considerable undertaking.  相似文献   

14.
Previous studies have identified associations between traffic-related air pollution and adverse health effects. Most have used measurements from a few central ambient monitors and/or some measure of traffic as indicators of exposure, disregarding spatial variability and factors influencing personal exposure-ambient concentration relationships. This study seeks to utilize publicly available data (i.e., central site monitors, geographic information system, and property assessment data) and questionnaire responses to predict residential indoor concentrations of traffic-related air pollutants for lower socioeconomic status (SES) urban households.As part of a prospective birth cohort study in urban Boston, we collected indoor and outdoor 3–4 day samples of nitrogen dioxide (NO2) and fine particulate matter (PM2.5) in 43 low SES residences across multiple seasons from 2003 to 2005. Elemental carbon (EC) concentrations were determined via reflectance analysis. Multiple traffic indicators were derived using Massachusetts Highway Department data and traffic counts collected outside sampling homes. Home characteristics and occupant behaviors were collected via a standardized questionnaire. Additional housing information was collected through property tax records, and ambient concentrations were collected from a centrally located ambient monitor.The contributions of ambient concentrations, local traffic and indoor sources to indoor concentrations were quantified with regression analyses. PM2.5 was influenced less by local traffic but had significant indoor sources, while EC was associated with traffic and NO2 with both traffic and indoor sources. Comparing models based on covariate selection using p-values or a Bayesian approach yielded similar results, with traffic density within a 50 m buffer of a home and distance from a truck route as important contributors to indoor levels of NO2 and EC, respectively. The Bayesian approach also highlighted the uncertanity in the models. We conclude that by utilizing public databases and focused questionnaire data we can identify important predictors of indoor concentrations for multiple air pollutants in a high-risk population.  相似文献   

15.
Residential concentrations of formaldehyde have been associated with poor respiratory health in children, where formaldehyde has been measured using stationary monitors inside homes. Although children spend most of their time indoors at home, there are few studies of children’s personal exposure to formaldehyde. The aim of this study was to investigate the relationship between personal exposure formaldehyde concentrations, microenvironmental concentrations and time weighted exposure estimates in children.Forty-one primary school children (aged between 9 and 12 years) wore a personal passive sampler over two 24 h periods in two seasons and completed 24 h daily activity diaries and a questionnaire about lifestyle and behaviour. Samplers were co located indoors at home, outdoors at centralised locations and indoors at school for the corresponding period.Personal exposure formaldehyde concentrations in this group of children were generally low with a geometric mean concentration of 9.1 ppb (range <detection limit to 27.3 ppb). There were strong correlations between personal exposure concentrations and both domestic indoor (rs = .779, p < 0.001) and time weighted estimated (rs = .802, p < 0.001) concentrations. The time weighted model did not improve the estimate of personal exposure compared with stationary indoor concentrations. Indoor air concentration measured with a single stationary monitor was a suitable surrogate for personal exposure.  相似文献   

16.
As part of a major study to investigate the indoor air quality in residential houses in Singapore, intensive aerosol measurements were made in an apartment in a multistory building for several consecutive days in 2004. The purpose of this work was to identify the major indoor sources of fine airborne particles and to assess their impact on indoor air quality for a typical residential home in an urban area in a densely populated country. Particle number and mass concentrations were measured in three rooms of the home using a real-time particle counter and a low-volume particulate sampler, respectively. Particle number concentrations were found to be elevated on several occasions during the measurements. All of the events of elevated particle concentrations were linked to indoor activities based on house occupant log entries. This enabled identification of the indoor sources that contributed to indoor particle concentrations. Activities such as cooking elevated particle number concentrations < or =2.05 x 10(5) particles/cm3. The fine particles collected on Teflon filter substrates were analyzed for selected ions, trace elements, and metals, as well as elemental and organic carbon (OC) contents. To compare the quality of air between the indoors of the home and the outdoors, measurements were also made outside the home to obtain outdoor samples. The chemical composition of both outdoor and indoor particles was determined. Indoor/outdoor (I/O) ratios suggest that certain chemical constituents of indoor particles, such as chloride, sodium, aluminum, cobalt, copper, iron, manganese, titanium, vanadium, zinc, and elemental carbon, were derived through migration of outdoor particles (I/O <1 or - 1), whereas the levels of others, such as nitrite, nitrate, sulfate, ammonium, cadmium, chromium, nickel, lead, and OC, were largely influenced by the presence of indoor sources (I/O >1).  相似文献   

17.
This paper reports on the development of a land use regression (LUR) model for predicting the intraurban variation of traffic-related air pollution in Hamilton, Ontario, Canada, an industrial city at the western end of Lake Ontario. Although land use regression has been increasingly used to characterize exposure gradients within cities, research to date has yet to test whether this method can produce reliable estimates in an industrialized location. Ambient concentrations of nitrogen dioxide (NO2) were measured for a 2-week period in October 2002 at > 100 locations across the city and subsequently at 30 of these locations in May 2004 to assess seasonal effects. Predictor variables were derived for land use types, transportation, demography, and physical geography using geographic information systems. The LUR model explained 76% of the variation in NO2. Traffic density, proximity to a highway, and industrial land use were all positively correlated with NO2 concentrations, whereas open land use and distance from the lake were negatively correlated with NO2. Locations downwind of a major highway resulted in higher NO2 levels. Cross-validation of the results confirmed model stability over different seasons. Our findings demonstrate that land use regression can effectively predict NO2 variation at the intraurban scale in an industrial setting. Models predicting exposure within smaller areas may lead to improved detection of health effects in epidemiologic studies.  相似文献   

18.
The purpose of this study was to derive a land-use regression model to estimate on a geographical basis ambient concentrations of nitrogen dioxide (NO2) in Montreal, Quebec, Canada. These estimates of concentrations of NO2 will be subsequently used to assess exposure in epidemiologic studies on the health effects of traffic-related air pollution. In May 2003, NO2 was measured for 14 consecutive days at 67 sites across the city using Ogawa passive diffusion samplers. Concentrations ranged from 4.9 to 21.2 ppb (median 11.8 ppb). Linear regression analysis was used to assess the association between logarithmic concentrations of NO2 and land-use variables derived using the ESRI Arc 8 geographic information system. In univariate analyses, NO2 was negatively associated with the area of open space and positively associated with traffic count on nearest highway, the length of highways within any radius from 100 to 750 m, the length of major roads within 750 m, and population density within 2000 m. Industrial land-use and the length of minor roads showed-no association with NO2. In multiple regression analyses, distance from the nearest highway, traffic count on the nearest highway, length of highways and major roads within 100 m, and population density showed significant associations with NO2; the best-fitting regression model had a R2 of 0.54. These analyses confirm the value of land-use regression modeling to assign exposures in large-scale epidemiologic studies.  相似文献   

19.
Abstract

As part of a major study to investigate the indoor air quality in residential houses in Singapore, intensive aerosol measurements were made in an apartment in a multistory building for several consecutive days in 2004. The purpose of this work was to identify the major indoor sources of fine airborne particles and to assess their impact on indoor air quality for a typical residential home in an urban area in a densely populated country. Particle number and mass concentrations were measured in three rooms of the home using a real-time particle counter and a low-volume particulate sampler, respectively. Particle number concentrations were found to be elevated on several occasions during the measurements. All of the events of elevated particle concentrations were linked to indoor activities based on house occupant log entries. This enabled identification of the indoor sources that contributed to indoor particle concentrations. Activities such as cooking elevated particle number concentrations ≤2.05 × 105 particles/cm3. The fine particles collected on Teflon filter substrates were analyzed for selected ions, trace elements, and metals, as well as elemental and organic carbon (OC) contents. To compare the quality of air between the indoors of the home and the outdoors, measurements were also made outside the home to obtain outdoor samples. The chemical composition of both outdoor and indoor particles was determined. Indoor/outdoor (I/O) ratios suggest that certain chemical constituents of indoor particles, such as chloride, sodium, aluminum, cobalt, copper, iron, manganese, titanium, vanadium, zinc, and elemental carbon, were derived through migration of outdoor particles (I/O<1 or ≈1), whereas the levels of others, such as nitrite, nitrate, sul-fate, ammonium, cadmium, chromium, nickel, lead, and OC, were largely influenced by the presence of indoor sources (I/O >1).  相似文献   

20.
This study identified the key determinants associated with the indoor benzene concentrations that were measured between 1996 and 2000 using the EXPOLIS protocol in the residences of six European cities, including Athens (Greece), Basel (Switzerland), Helsinki (Finland), Milan (Italy), Oxford (United Kingdom), and Prague (Czech Republic). Two consecutive days of home indoor and home outdoor measurements of benzene were carried out at the homes of adult participants on different dates and seasons during the sampling period. Regression models, with interactions searched by all-possible subset method, were used to assess the city effects and the determinants of home indoor benzene (adjusted R2=0.57, n=412). Outdoor benzene concentrations, outdoor temperature, wind speed, the use of anti-moth products, and indoor smoking in terms of number of cigarettes consumed per day were shown to be the key determinants of indoor benzene concentrations. The model was further used to predict the indoor benzene levels in cities. Non-linear relationships were commonly found, indicating that a unit change in the indoor concentration cannot be simply estimated by a proportional change of the determinant, and the pattern of relationships could be differed in different places. This finding is important in formulating indoor air quality guidelines as well as calculating an accurate health risk estimate based on the estimates of population's lifetime exposure levels.  相似文献   