共查询到20条相似文献,搜索用时 15 毫秒
1.
Raymond J. Supalla Dorothy A. Comer 《Journal of the American Water Resources Association》1982,18(4):679-686
ABSTRACT: Artificial recharge as a means of augmenting water sup plies for irrigation is a management alternative which policy makers in ground water decline areas are beginning to consider seriously. A conceptual model is developed to evaluate the economic benefits from ground water recharge under conditions where the major water use is irrigation. The methodology presented separates recharge benefits into two components: pumping cost savings and aquifer extension benefits. This model is then applied to a Nebraska case to approximate the value of recharge benefits as a function of aquifer response. discount rate, and commodity prices. It was found that recharge benefits vary from less than $2 to over $6 an acre foot recharged. 相似文献
2.
Adrian H. Griffin James C. Wade William E. Martin 《Journal of the American Water Resources Association》1980,16(5):849-855
ABSTRACT: The ground water in the Tucson basin is being drawn faster than it is replenished by nature. The water table is falling, giving rise to several conflicts between water users in the basin. At present, several lawsuits are in progress, including an action by the Papago Tribe against some of the major water users in the basin. Largely because of these difficulties, the State Legislature has established a commission to make proposals for the reform of Arizona's ground water law. The pattern of water use in the basin will undoubtedly be changed by the outcome of the present litigation and the coming reform of Arizona's ground water law. This paper describes how water use in the basin might be affected by changes in the availability of water and gives an account of the effects that these changes in water use could have on the region's economy. The paper concludes that the water problems of the Tucson basin will have little effect on the region at large and that these problems are simply a matter for the Indians and the other water users in the basin to sort out amongst themselves. 相似文献
3.
ABSTRACT: Stable isotopes of deuterium and oxygen-18 of surface and ground water, together with anion concentrations and hydraulic gradients, were used to interpret mixing and flow in ground water impacted by artificial recharge. The surface water fraction (SWF), the percentage of surface water in the aquifer impacted via recharge, was estimated at different locations and depths using measured deuterium/hydrogen (DIH) ratios during the 1992, 1993, and 1994 recharge seasons. Recharged surface water completely displaced the ground water beneath the recharge basins from the regional water table at 7.60 m to 12.16 m below the land surface. Mixing occurred beneath the recharge structures in the lower portions of the aquifer (>12.16 m). Approximately 12 m down-gradient from the recharge basin, the deeper zone (19.15 m depth) of the primary aquifer was displaced completely by recharged surface water within 193, 45, and 55 days in 1992, 1993, and 1994, respectively. At the end of the third recharge season, recharged surface water represented ~50 percent of the water in the deeper zone of the primary aquifer ~1000 m downgradient from the recharge basin. A classic asymmetrical distribution of recharged surface water resulted from the recharge induced horizontal and vertical hydraulic gradients. The distribution and breakthrough times of recharged surface water obtained with stable isotopes concurred with those of major anions and bromide in a tracer test conducted during the 1995 recharge season. This stable isotope procedure effectively quantified mixing between surface and ground water. 相似文献
4.
M. R. Karlinger A. J. Hansen 《Journal of the American Water Resources Association》1983,19(6):967-975
ABSTRACT: Appraisal-level, engineering economic analyses for two types of irrigation systems are compared: (1) a surface-water irrigation system, and (2) a ground-water recharge irrigation system. An artificial recharge irrigation system is an economically viable alternative to surface-distributed irrigation in a conjunctive irrigation plan if electric power rates remain sufficiently low. As electric rates increase, this viability generally decreases until it becomes completely unattractive at rates of about 0.012 dollars per kilowatt hour. 相似文献
5.
N. K. Dokoozlian V. E. Petrucci J. E. Ayars C. D. Clary R. A. Schoneman 《Journal of the American Water Resources Association》1987,23(2):307-311
ABSTRACT: The potential for artificial ground water recharge by continuous flooding of dormant grapevines was evaluated in the San Joaquin Valley of California using the cultivar Thompson Seedless. The study was started in 1982 and was completed in 1985 after three complete flooding cycles during dormancy. An average daily rate of recharge of 80 mm/thy for a 32-day period each year was achieved through a clay loam soil. There were no adverse effects on the grapevines and yields in the flooded plots in any of the growing seasons following recharge periods. Yields were higher in the recharge plots than in the control plots in the last year of the study. We conclude that artificial ground water recharge by continuous flooding during grapevine dormancy is a viable recharge method. 相似文献
6.
Chen‐Wuing Liu Han‐Chen Huang Shih‐Kai Chen Yi‐Ming Kuo 《Journal of the American Water Resources Association》2004,40(3):603-614
ABSTRACT: This study estimates subsurface return flow and effective ground water recharge in terraced fields in northern Taiwan. Specifically, a three dimensional model, FEMWATER, was applied to simulate percolation and lateral seepage in the terraced fields under various conditions. In the terraced paddy fields, percolation mainly moves vertically downward in the central area, while lateral seepage is mainly focused around the bund. Although the simulated lateral seepage rate through the bund exceeded the percolation rate in the central area of the paddy field, annual subsurface return flow at Pei‐Chi and Shin‐Men was 0.17 × 106 m3 and 0.37 × 106 m3, representing only 0.17 percent and 0.21 percent of the total irrigation water required for rice growth at Pei‐Chi and Shin‐Men, respectively. For upland fields, the effective ground water recharge rate during the second crop period (July to November) exceeded that during the first crop period (January to May) because of the wet season in the second crop period. Terraced paddy fields have the most efficient ground water recharge, with 21.2 to 23.4 percent of irrigation water recharging to ground water, whereas upland fields with a plow layer have the least efficient ground water recharge, with only 4.8 to 6.6 percent of irrigation water recharging to ground water. The simulation results clearly revealed that a substantial amount of irrigation water recharges to ground water in the terraced paddy, while only a small amount of subsurface return flow seeps from the upstream to the downstream terraced paddy. The amounts of subsurface flow and ground water recharge determined in the study are useful for the irrigation water planning and management and provide a scientific basis to reevaluate water resources management in the terrace region under irrigated rice. 相似文献
7.
Chin Y. Lee A. Raziq Qazi Jeris A. Danielson 《Journal of the American Water Resources Association》1980,16(3):514-522
ABSTRACT: Under Colorado's appropriative water right system, withdrawals by junior ground water rights must be curtailed to protect senior surface water appropriators sharing the same river system unless the ground water users replace the amount of their injury to the river under an approved plan for augmentation. Compensation of such injury with surface water may not only be expensive but unreliable in dry years. As an alternative, the curtailment of pumping may be obviated by recharging unused surface water into the aquifer when available and withdrawing it when needed. In order to manage such an operation, a practical tool is required to accurately determine that portion of the recharge water that does not return to the river before pumping for irrigation. A digital model was used for this purpose in a demonstration recharge project located in the South Platte River basin in northeastern Colorado. This paper summarizes the experiences gained from this project, the results of the digital model, the economic value of recharge, and the feasibility of the operation. It was determined through the use of the digital model that, with the given conditions in the area, 77 percent of the recharged water remained available for pumping. Economic analyses showed that water could be recharged inexpensively averaging about two dollars per acre foot. 相似文献
8.
Geoffrey N. Delin William N. Herkelrath 《Journal of the American Water Resources Association》2005,41(6):1259-1277
Soil moisture data collected using an automated data logging system were used to estimate ground water recharge at a crude oil spill research site near Bemidji, Minnesota. Three different soil moisture probes were tested in the laboratory as well as the field conditions of limited power supply and extreme weather typical of northern Minnesota: a self‐contained reflectometer probe, and two time domain reflectometry (TDR) probes, 30 and 50 cm long. Recharge was estimated using an unsaturated zone water balance method. Recharge estimates for 1999 using the laboratory calibrations were 13 to 30 percent greater than estimates based on the factory calibrations. Recharge indicated by the self‐contained probes was 170 percent to 210 percent greater than the estimates for the TDR probes regardless of calibration method. Results indicate that the anomalously large recharge estimates for the self‐contained probes are not the result of inaccurate measurements of volumetric moisture content, but result from the presence of crude oil, or borehole leakage. Of the probes tested, the 50 cm long TDR probe yielded recharge estimates that compared most favorably to estimates based on a method utilizing water table fluctuations. Recharge rates for this probe represented 24 to 27 percent of 1999 precipitation. Recharge based on the 30 cm long horizontal TDR probes was 29 to 37 percent of 1999 precipitation. By comparison, recharge based on the water table fluctuation method represented about 29 percent of precipitation. 相似文献
9.
Amitabha Mukhopadhyay Ferenc Szekely Yildir Senay 《Journal of the American Water Resources Association》1994,30(6):1091-1107
ABSTRACT: Injection of water and subsequent withdrawal were carried out in three existing water wells (SU-10, C-105, and SU-135A) in Kuwait. The objective of the study was to assess the technical feasibility of artificial recharge in the carbonate Dammam Formation and the clastic Kuwait Group aquifers. In the absence of any pretreatment of injection water and measures for maintenance of line pressure, clogging from suspended solids and air entrapment occurred in all three experiments. It was, however, possible to inject for one month in Wells SU-10 and C-105 where injection took place in the Dammam aquifer. In Well SU-135A, where the Kuwait Group aquifer was the target for injection, clogging became so severe that the injection experiment had to be abandoned. The injection/withdrawal data were analyzed with the help of a multi-aquifer flow model and a transport model. The models took into account the effects of crossflow within the boreholes on the distribution of intake and discharge rates for different aquifers, and hence, on the recovery efficiency. The experiments suggested that the artificial recharge of the Dammam and the Kuwait Group aquifers was technically feasible. The problem of clogging was, however, more severe for the Kuwait Group. 相似文献
10.
AUTOMATED METHODS FOR ESTIMATING BASEFLOW AND GROUND WATER RECHARGE FROM STREAMFLOW RECORDS1 总被引:1,自引:0,他引:1
ABSTRACT: To quantify and model the natural ground water recharge process, six sites located in the midwest and eastern United States where previous water balance observations had been made were compared to computerized techniques to estimate: (1) base flow and (2) ground water recharge. Results from an existing automated digital filter technique for separating baseflow from daily streamflow records were compared to baseflow estimates made in the six water balance studies. Previous validation of automated baseflow separation techniques consisted only of comparisons with manual techniques. In this study, the automated digital filter technique was found to compare well with measured field estimates yielding a monthly coefficient of determination of 0.86. The recharge algorithm developed in this study is an automated derivation of the Rorabaugh hydrograph recession curve displacement method that utilizes daily streamflow. Comparison of annual recharge from field water balance measurements to those computed with the automated recession curve displacement method had coefficients of determination of 0.76 and predictive efficiencies of 71 percent. Monthly estimates showed more variation and are not advocated for use with this method. These techniques appear to be fast, reproducible methods for estimating baseflow and annual recharge and should be useful in regional modeling efforts and as a quick check on mass balance techniques for shallow water table aquifers. 相似文献
11.
ABSTRACT: Ground water nitrate contamination and water level decline are common concern in Nebraska. Effects of artificial recharge on ground water quality and aquifer storage recovery (ASR) were studied with spreading basins constructed in the highly agricultural region of the Central Platte, Nebraska. A total of 1.10 million m3 of Platte River water recharged the aquifer through 5000 m2 of the recharge basins during 1992, 1993, and 1994. This is equivalent to the quantity needed to completely displace the ground water beneath 34 ha of the local primary aquifer with 13 m thickness and 0.25 porosity. Successful NO3-N remediation was documented beneath and downgradient of the recharge basins, where NO3-N declined from 20 to 2 mg L-1. Ground water atrazine concentrations at the site decreased from 2 to 0.2 mg L-1 due to recharge. Both NO3-N and atrazine contamination dramatically improved from concentrations exceeding the maximum contaminant levels to those of drinking water quality. The water table at the site rose rapidly in response to recharge during the early stage then leveled off as infiltration rates declined. At the end of the 1992 recharge season, the water table 12 m downgradient from the basins was elevated 1.36 m above the preproject level; however, at the end of the 1993 recharge season, any increase in the water table from artificial recharge was masked by extremely slow infiltration rates and heavy recharge from precipitation from the wettest growing season in over 100 years. The water table rose 1.37 m during the 1994 recharge season. Resultant ground water quality and ASR improvement from the artificial recharge were measured at 1000 m downgradient and 600 m upgradient from the recharge basins. Constant infiltration rates were not sustained in any of the three years, and rates always decreased with time presumably because of clogging. Scraping the basin floor increased infiltration rates. Using a pulsed recharge to create dry and wet cycles and maintaining low standing water heads in the basins appeared to reduce microbial growth, and therefore enhanced infiltration. 相似文献
12.
ABSTRACT This study examined the feasibility of extending the Accelerated Salt Transport (ASTRAN) method of groud water quality control to a complex, closed basin which is experiencing ground water quality degradation from irrigated agriculture (e.g., the Tulare Lake Basin in the Southern portion of the California Central Valley). A linear programming model was constructed and parametric analysis conducted which produced results with a “general appraisal” (or “level B”) degree of accuracy. The study concluded that a drainage water export drain is required in order to implement a long-term solution but that ground water degradation can be mitigated by a combination of the ASTRAN method and other measures even with existing entitlements and legal constraints. 相似文献
13.
John C. S. Tang Suchart Tanthimakabut 《Journal of the American Water Resources Association》1981,17(5):783-788
A ground water development project in the northern part of Thailand was appraised by means of benefit-cost analysis. This is the first project in Thailand to develop ground water for irrigation purposes and it is also the first project which made use of an underground PVC pipe water distribution system. Results indicate that the project is economically feasible. In comparing different water distribution systems, it is also found that distribution by means of underground PVC pipes is more economical compared to an open ditch system if the life of the latter is relatively short and the rates of inflation are high. 相似文献
14.
Siddhartha Bagchi Alvin S. Goodman 《Journal of the American Water Resources Association》1979,15(2):536-549
ABSTRACT: This paper focuses on the development and testing of a mathematical model of an emergency ground water supply operated principally during periods of low streamflow. The process of ground water withdrawal and recharge is simulated taking account of streamflow, water demand, evapotranspiration, natural and artificial recharge and increased evapotranspiration due to artificial recharge, ground water pumpage, and streamflow contribution to pumped water. The model determines whether natural recharge is possible in less time than the return period of drought and also whether artificial recharge is needed. By simulating operation over a long period of time, the model can examine different droughts of short and long duration and can test the operating rules for ground water storage development in an area. Submodels analyze the components of the operating process including ground water flow into the stream, seepage losses, stream portion of well discharge due to induced infiltration and recharge from rainfall or water spreading. The model has been tested for areas in the humid northeastern United States. 相似文献
15.
Geoffrey N. Delin Richard W. Healy Matthew K. Landon John Karl Bhlke 《Journal of the American Water Resources Association》2000,36(6):1401-1416
ABSTRACT: Field experiments were conducted from 1992 to 1995 to estimate ground water recharge rates at two sites located within a 2.7‐hectare agricultural field. The field lies in a sand plain setting in central Minnesota and is cropped continuously in field corn. The sites are located at a topographically high (upland) site and a topographically low (lowland) site in an effort to quantify the effects of depression focusing of recharge. Three site‐specific methods were used to estimate recharge rates: well hydrograph analysis, chlorofluorocarbon age dating, and an unsaturated zone water balance. All three recharge methods indicated that recharge rates at the lowland site (annual average of all methods of 29 cm) exceeded those at the upland site (annual average of 18 cm). On an annual basis, estimates by the individual methods ranged from 12 to 44 percent of precipitation at the upland site and from 21 to 83 percent at the lowland site. The difference in recharge rates between the sites is primarily attributed to depression focusing of surface water runon at the lowland site. However, two other factors were also important: the presence of thin lamellae at the upland site, and coarser textured soils below a depth of 1.5 m at the lowland site. 相似文献
16.
Charles W. Abdalla 《Journal of the American Water Resources Association》1990,26(3):451-463
ABSTRACT: Economic losses from ground water contamination were estimated in a central Pennsylvania community. The averting expenditures method was applied via a mail survey of households in which water contained the unregulated volatile organic chemical, perchloroethylene (PCE). Expenditures were estimated at $148,900 (1987 dollars) over the six-month contamination period or approximately $252 per household annually. These costs underestimate the lower bound measure of welfare losses to households from ground water contamination. An upper bound measure of welfare losses was estimated at $383 per household annually. These estimates do not represent the full economic losses resulting from ground water contamination since the study did not address municipal-level and business avoidance costs and losses from actual health effects, increased fear and anxiety, ecological damages, and nonuser ground water benefits. The results expand the existing empirical base of information about municipal-level responses and economic losses from ground water contamination to include household-level impacts. The findings indicate that households undertake substantial averting actions in response to ground water contamination and that such actions can have significant economic consequences. The extent and magnitude of avoidance costs documented suggests that policy-makers should give greater attention to this category of economic losses. 相似文献
17.
Robert M. Kahn Bruce D. Smith Austin Long 《Journal of the American Water Resources Association》1996,32(3):629-635
ABSTRACT: A study of 222Rn concentrations in the water distribution system of Tucson, Arizona, revealed levels of 60 to 1260 pCi/L in domestic waters. These measurements are comparable to levels of between 80 and 1400 pCi/l for 222Rn found in ground water samples in the North-Central Tucson basin (Kahn et al., 1994). Estimated loss of 222Rn due to radioactive decay during travel from the well head to the home ranges from 8 to 50 percent. 相似文献
18.
James W. Warner David Molden Mondher Chehata Daniel K Sunada 《Journal of the American Water Resources Association》1989,25(2):401-411
ABSTRACT: One of the most common methods of artificial recharge to the ground water is from basins. In this paper, seven analytical solutions that describe artificial recharge from basins are presented. Most of these solutions are derived by directly solving the general partial differential equation for ground water flow. The solutions differ in that they use different boundary conditions, basin shapes, and consider the nonlinearity of the artificial recharge problem differently. Use of each analytical solution is demonstrated in this paper by application to an example problem. A comparison of each analytical solution presented in this paper was made to give suggestions on their use, their ease of implementation, and their relative agreement. Although no attempt is made in the paper to conclude which analytical solution is best for all problems, some general conclusions can be stated on the applicability of the various analytical solutions. Of the analytical solutions presented in this paper, Glovers and Hantush's solutions for rectangular recharge basins are highly recommended. Baumanns solution for a circular basin also gave fairly reliable results and is very easy to evaluate numerically. 相似文献
19.
Marios Sophocleous J. A. McAllister 《Journal of the American Water Resources Association》1987,23(6):997-1010
ABSTRACT: A detailed but simple hydrologic budget for the entire Rattlesnake Creek basin (3,768 km2) in south-central Kansas was developed. With this budget, using minimal daily-weather input data and the soil-plant-water system-analysis methodology, we were able to characterize the spatial distribution of the hydrologic components of the water balance within the basin. A combination of classification and meteorological methods resulted in a basinwide integration methodology. Using this methodology, we found that, in addition to obvious climatic controls, soil, vegetation, and land-use factors also exert considerable influence on the water balance of the area. The available-water capacity (AWC) of soil profiles plays a dominant role in soil-water-deficit development and deep drainage. Vegetation and dryland or irrigated farming particularly affect the evapotranspiration (ET) components, with ET from irrigated corn and alfalfa being two to three times that from wheat. Deep drainage from irrigated wheat fields was found to be significantly higher than that from grassland and dryland wheat; deep drainage from alfalfa is practically nonexistent. We demonstrated how vegetation changes may affect components of the hydrologic cycle. We also showed that different portions of the watershed have different water-balance components and that use of single average values of hydrologic variables in management practices may not be realistic. 相似文献
20.
Eric G. Reichard John D. Bredehoeft 《Journal of the American Water Resources Association》1984,20(6):929-939
This study describes and demonstrates two alternate methods for evaluating the relative costs and benefits of artificial groundwater recharge using percolation ponds. The first analysis considers the benefits to be the reduction of pumping lifts and land subsidence; the second considers benefits as the alternative costs of a comparable surface delivery system. Example computations are carried out for an existing artificial recharge program in Santa Clara Valley in California. A computer groundwater model is used to estimate both the average long term and the drought period effects of artificial recharge in the study area. For the example problem, the benefits of reduced average annual pumping lifts and reduced incremental subsidence are greater than the total costs of continuing the existing artificial recharge program. Benefits for reduced subsidence are strongly dependent on initial aquifer conditions. The second analysis compares the costs of continuing the artificial recharge program with the costs of a surface system which would achieve the same hydraulic effects. Results indicate that the costs of artificial recharge are considerably smaller than the alternative costs of an equivalent surface system. In evaluating a particular program, consideration should also be given to uncertainties in future supplies and demands for water as well as to the probability of extreme events such as droughts. 相似文献