首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 312 毫秒
1.
Atmospheric deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) was investigated at four locations, namely at Yuancun, Wushan, Haizhu and Changban in Guangzhou City, Guangdong Province. The annual deposition fluxes of tetra- to octa-CDD/Fs (total PCDD/Fs) were found to range from 170 to 3000 (mean 1500) pg m−2 day−1, and the fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners ranged from 2.1 to 41 (mean 20) pg WHO-TEQ m−2 day−1 at Wushan. The average deposition fluxes of total 2, 3, 7, 8-substituted PCDD/F congeners in rainy season were found to be 37, 27 and 28 pg WHO-TEQ m−2 day−1 at Yuancun, Haizhu and Changban, respectively, and the PCDD/F deposition fluxes behaved obviously higher in rainy season than in dry season. Results from regression analysis showed that number of rainy days, the amount of wet precipitation, PCDD/F concentrations in particles and organic carbon content played important roles in the variation of PCDD/F deposition fluxes. Monthly average temperatures change little over the year. Therefore, it only played a minor role in monthly variation of PCDD/F deposition fluxes. Particle deposition fluxes were generally not considered as the factor that could cause the differences in PCDD/F deposition fluxes between rainy and dry season, but were found to be related with PCDD/F deposition fluxes in rainy season or dry season. It was found that the profiles of PCDD/F homologs or congeners in the samples were the same either spatially or temporally, indicating that the PCDD/F emission sources were similar to one another. The similarities in PCDD/F homolog patterns and the differences in deposition fluxes between samples collected from heavy-traffic roadside and nearby residence house roof indicated that vehicle exhaust might be an important source for PCDD/F in Guangzhou. PCDD/F concentrations and profiles of PCDD/F homologs in atmospheric deposition were compared with those in both total suspended particles in air and soils, and conclusions indicated that atmospheric deposition possibly tended to remove lower-chlorinated DD/Fs from air and was one of sources for PCDD/Fs in soils.  相似文献   

2.
Atmospheric concentrations and deposition fluxes of PCDD/F and PCB have been evaluated over a 1-year period in a Mediterranean coastal lagoon (Etang de Thau, France). Indicative PBDE air concentrations in the hot season are also reported in this work. ∑2,3,7,8-PCDD/Fs and ∑18PCBs (gas + particulate) air concentrations ranged from 67 to 1700 fg m−3 and from 13 to 95 pg m−3, respectively whereas ∑8PBDEs (gas + particulate) summer time levels varied from 158 to 230 pg m−3. The PCDD/F and PCB atmospheric occurrence over Thau lagoon and subsequent inputs to the surface waters are determined by an assemble of factors, being the seasonality of atmospheric concentration, the air mass origin and meteorological conditions important drivers. Total (wet + dry) ∑2,3,7,8-PCDD/Fs and ∑18PCBs deposition fluxes to Thau Lagoon waters are 117 and 715 pg m−2 d−1, respectively.  相似文献   

3.
Fang M  Choi SD  Baek SY  Park H  Chang YS 《Chemosphere》2011,84(7):894-899
An IRA-743 resin bulk sampler was validated to monitor long-term bulk deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). Six consecutive sampling campaigns (2008-2009) were conducted at four sites around steel complexes in Pohang, South Korea to investigate spatial and seasonal variations of PCDD/F bulk deposition. The bulk deposition within the steel complex showed the highest ∑4-8PCDD/F (Tetra-Octa) fluxes, ranging from 204 to 608 (mean: 352) pg m−2 d−1, indicating steel complexes were major sources of PCDD/Fs. The homologue profiles were dominated with lower chlorinated PCDFs. Furthermore, the prevailing winds were confirmed to influence the spatial distribution of PCDD/F deposition. There were apparent seasonal variations of the bulk deposition at each site, and seasonal homologue patterns of PCDD/Fs were clearly observed. According to the passive air sampling, however, no significant seasonal change of ambient air concentrations of PCDD/Fs was observed. Therefore, it was concluded that the seasonal variations of deposition fluxes of PCDD/Fs probably resulted from temperature-dependent gas/particle partitioning.  相似文献   

4.
Concentrations and profiles of 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) were investigated in sediment and plants collected from a salt marsh in the Tejo estuary, Portugal. The highest PCDD/F and dl-PCB concentrations were detected in uncolonized sediments, averaging 325.25?±?57.55 pg g?1 dry weight (dw) and 8,146.33?±?2,142.14 pg g?1 dw, respectively. The plants Sarcocornia perennis and Halimione portulacoides growing in PCDD/F and dl-PCB contaminated sediments accumulated contaminants in roots, stems, and leaves. It was observed that PCDD/F and dl-PCB concentrations in roots were significantly lower in comparison with stems and leaves. In general, concentration of ΣPCDD/Fs and Σdl-PCBs in H. portulacoides tissues were found to be twofold higher than those in S. perennis, indicating a difference in the accumulation capability of both species. Furthermore, congener profiles changed between sediments and plant tissues, reflecting a selective accumulation of low chlorinated PCDD/Fs and non-ortho dl-PCBs in plants.  相似文献   

5.
Most polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in the atmosphere are bound to particles which are suspended in the atmosphere, and eventually settle on soil, vegetation, water bodies or other receptors in the environment. Monitoring atmospheric deposition fluxes (dry/wet) is important in tracing the environmental fate and behavior of PCDD/Fs. PCDD/F depositions were collected via an automated PCDD/F ambient sampler and traditional cylindrical vessels, respectively, from April 2007 to February 2008. The automated PCDD/F ambient sampler used in this study can prevent both re-suspension and photo degradation of the PCDD/Fs collected and effectively separates the PCDD/F samples into dry and wet contributions. The results indicated that the ambient PCDD/F concentrations collected using the PS-1 sampler ranged from 0.02 pg I-TEQ/m3 to 0.16 pg I-TEQ/m3 in Northern Taiwan. The results also indicated that the PCDD/F deposition flux collected using the automated PCDD/F sampler (17.5 pg I-TEQ/m2 d to 25.8 pg I-TEQ/m2 d) was significantly higher than that sampled with the cylindrical vessels (2.0 pg I-TEQ/m2 d to 9.9 pg I-TEQ/m2 d). The difference was attributed to the fact that part of the PCDD/F depositions collected using the traditional cylindrical vessels had undergone photo degradation and evaporation. In addition, the wet deposition flux of PCDD/Fs (39.4 pg I-TEQ/m2 rainy day to 228 pg I-TEQ/m2 rainy day) observed in this study was significantly higher than the dry deposition flux (12.3 pg I-TEQ/m2 sunny day to 16.7 pg I-TEQ/m2 sunny day). These results demonstrated that wet deposition is the major PCDD/F removal mechanism in the atmosphere.  相似文献   

6.
PCDD/F contamination of the Baltic Sea has resulted in the European Union imposing restrictions on the marketing of several fish species. Atmospheric deposition is the major source of PCDD/Fs to the Baltic Sea, and hence there is a need to identify the source regions of the PCDD/Fs in ambient air over the Baltic Sea. A novel monitoring strategy was employed to address this question. During the winter of 2006–2007 air samples were collected in Aspvreten (southern Sweden) and Pallas (northern Finland). Short sampling times (24 h) were employed and only samples with stable air mass back trajectories were selected for analysis of the 2,3,7,8-substituted PCDD/F congeners. The range in the PCDD/F concentrations from 40 samples collected at Aspvreten was a factor of almost 50 (range 0.6–29 fg TEQ/m3). When the samples were grouped according to air mass origin into seven compass sectors, the variability was much lower (typically less than a factor of 3). This indicates that air mass origin was the primary source of the variability. The contribution of each sector to the PCDD/F contamination over the Baltic Sea during the winter half year of 2006/2007 was calculated from the average PCDD/F concentration for each sector and the frequency with which the air over the Baltic Sea came from that sector. Air masses originating from the south–southwest, south–southeast and east segments contributed 65% of the PCDDs and 75% of the PCDFs. Strong correlations were obtained between the concentrations of most of the PCDD/F congeners and the concentration of soot. These correlations can be used to predict the PCDD/F concentrations during the winter half year from inexpensive soot measurements.  相似文献   

7.
Recent reports have suggested that dietary and environmental estrogens such as organochlorine pollutants may play a role in the increased incidence of breast cancer in women and disorders of the male reproductive tract. For example, elevated levels of DDE and polychlorinated biphenyls (PCB) have been measured in women with breast cancer. However, it should also be noted that numerous environmental and dietary compounds have also been characterized as antiestrogenic and as inhibitors of mammary cancer cell growthin vitro and/orin vivo. Some of these compounds include 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and related compounds, polynuclear aromatic hydrocarbons (PAH), other naturally-occurring TCDD receptor agonists, retinoids, phorbol esters, terpenes, fatty acids, and polysaccharides. Thus, it is possible that dietary and environmental estrogens and antiestrogens may be contra-active, and these interactions must be considered in the overall risk assessment of the potential adverse human and environmental health impacts of these chemicals.  相似文献   

8.
Polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) are organic chemicals of suspected extreme toxicity. PCDD/Fs are ubiquitous in the environment and relatively enriched in sewage sludges. The deliberate application of sewage sludge to agricultural land can therefore potentially increase exposure of the human population to these compounds via transfers through the foodchain. This paper presents a protocol for assessing the background human exposure to all seventeen 2,3,7,8-substituted PCDD/Fs for which toxic equivalent factors (TEFs) are available. Background daily human exposure in the UK to 2,3,7,8-T(4)CDD and I-TEQ are calculated to be 0.0239 ng and 0.203 ng, respectively. The potential increases in crop plant and livestock tissue PCDD/F concentrations, and hence in human exposure, following applications of sewage sludge to agricultural land are quantified for different sludge application scenarios. The key role of PCDD/F transfer into livestock via ingestion of sludge adhered to vegetation in determining increases in human exposure is demonstrated.  相似文献   

9.
PCDD/F and PCB history in dated sediments of a rural lake   总被引:1,自引:0,他引:1  
Concentrations of polychlorinated dibenzo-p-dioxins (PCDD), dibenzofurans (PCDF) and biphenyls (PCB) were analysed from a sediment core, which had been sampled from a remote lake in Finland. The deepest subsamples were analysed from a depth of 4.0 m, and were more than 8000 years old. At the surface of the sediment core, low levels of industrial background contamination were detected. The sum of 2,3,7,8-substituted PCDD/Fs was 35 ng/kg d.w. (dry weight), or 1.2 ng/kg d.w. in WHO's toxicity equivalent, WHO-TEQ. The annual accumulation rate of 2,3,7,8-substituted PCDD/Fs was 1.26 ng m(-2) a(-1). Deeper in the core, PCDD/F concentrations ranged between 2.11 and 11.1 ng/kg d.w. (0.24 and 1.70 ng/kg d.w. WHO-TEQ) and the accumulation rate was 0.11 ng m(-2) a(-1). A characteristic PCDD/F congener profile was found in all pre-industrial sediment layers. The order of concentrations was OCDD > 1,2,3,4,6,7,8-HpCDD > 1,2,3,7,8,9-HxCDD > 1,2,3,4,7,8-HxCDD > 2,3,7,8-TCDD, and concentrations of 2,3,7,8-chlorinated dibenzofurans were below the detection limit. Similar congener profiles have previously been described in samples for which natural PCDD/F formation has been proposed. PCBs were present at low levels in all of the sediment samples. The sum of the PCB concentrations of the sediment subsamples ranged between 50 and 2540 ng/kg d.w., and the three predominant congeners in the core were PCBs 18, 52, and 110.  相似文献   

10.
Reductions in the apparent soil-water partition coefficients (Kd *) for 28 polychlorinated biphenyls (PCBs) caused by the surfactant sodium dodecylsulphate (SDS) in the aqueous phase were studied. Above the critical micelle concentration (CMC) of the surfactant, Kd * was reduced by 2–3 orders of magnitude, but even far below CMC at environmentally relevant surfactant concentrations significant reductions in Kd * were observed. The plot of the soil-water partition coefficient (Kd) divided by Kd * versus the concentration of SDS allowed for the calculation of monomer (Kmn oc) and micellar (Kmc oc) surfactant-water partition coefficients normalized to organic carbon for each PCB congener. Kmn oc values were comparable with published values for the partition of PCBs between natural dissolved organic matter and lake water. Kmc oc values were up to 30 times higher than Kmn oc values and comparable with published octanol-water distribution coefficients. The findings of the present study underline the potential of surfactants at concentrations below their CMC to mobilize otherwise strongly bound hydrophobic compounds in soil-water systems.  相似文献   

11.
With recent evidence that persistent organic pollutants (POPs) such as polychlorinated biphenyls (PCBs) are emerging in environmental media in some developing countries that otherwise have sparing production and usage history, it has become important to identify such contemporary source factors of PCBs and the risks this may pose, in line with the global consensus on POP management and elimination. The present study investigated contaminations from atmospheric PCBs in Ghana, deciphered source factors, and accessed risk of exposure to dioxin-like PCBs (DL-PCBs). Atmospheric PCBs were monitored by deployment of PUF-disk passive air samplers (PAS) at several sites across Ghana for 56 days. Atmospheric ∑190PCB concentration in Ghana ranged from 0.28 ng/m3 in Kumasi to 4.64 ng/m3 at Agbogbloshie, a suburb in Accra noted for informal electronic waste (e-waste) recycling activities. As high as 11.10 ng/m3 of PCB concentration was measured in plumes from uncontrolled open burning of e-wastes at Agbogbloshie. Applying statistical source characterization tools, it emerged that e-wastes were a major contributor to the environmental burden of atmospheric PCBs in Ghana. The risk of DL-PCB toxicity via inhalation in the Agbogbloshie area was 4.2 pg TEQ/day, within similar order of magnitude of an estimated risk of 3.85 pg TEQ/day faced by e-waste workers working averagely for 8 h per day. It is suggested that elimination of e-waste sites would help to significantly reduce PCB-related toxicity issues in Ghana.
Graphical abstract ?
  相似文献   

12.
Chi KH  Hsu SC  Lin CY  Kao SJ  Lee TY 《Chemosphere》2011,83(6):745-752
In this study, polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/F) concentrations and depositions in ambient air, water column and sediment were measured at a coupled reservoir-watershed system in northern Taiwan. The atmospheric PCDD/F concentration measured in the vicinity of the reservoir ranged from 4.9 to 39 fg I-TEQ m−3 and the Asian dust storm in February accounted for the peak value, which corresponded to a total suspended particle concentration of 128 μg m−3. The atmospheric PCDD/F deposition ranged from 1.4 to 19 pg I-TEQ m−2 d−1, with higher deposition occurring during winter and spring (long-range transport events). During summer, when atmospheric deposition is lower, consecutive tropical cyclones (typhoons) bring heavy rainfall that enhances soil erosion and creates turbidity-driven intermediate flow. This results in significantly higher PCDD/F deposition in water column of the reservoir at 70 m water depth (179 pg I-TEQ m−2 d−1) than at 20 m (21 pg I-TEQ m−2 d−1) during typhoon event. The accumulation rate of PCDD/Fs (9.1 ng I-TEQ m−2 y−1) in the reservoir sediments (depth: 0-2 cm) was consistent with PCDD/F deposition obtained from water column (6.1 and 8.3 ng I-TEQ m−2 y−1); however, it is significantly higher when compared to the atmospheric deposition (2.0 ng I-TEQ m−2 y−1). Based on the mass balance between the measurements of atmospheric deposition and sinking particles in water column, around 54-74% of PCDD/F inputs into the reservoir were contributed by the catchment erosion during normal period. However, the PCDD/F input contributed by the enhanced catchment erosion significantly increased to 90% during intensive typhoon events.  相似文献   

13.
Ni Y  Zhang Z  Zhang Q  Chen J  Wu Y  Liang X 《Chemosphere》2005,60(6):779-784
The purpose of this research was to determine polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) in five chlorinated chemicals (phthalocyanine copper, phthalocyanine green, chloranil-1 and 2, and triclosan), and to compare their 2,3,7,8-tetrachlordibenzo-IpI-dioxin equivalents (TEQ). The distribution patterns of total PCDD/Fs and 2,3,7,8-substituted PCDD/Fs were elucidated in detail. The TEQ values of toxic PCDD/Fs in all chemicals were in the range of 5.03-1379.55 ng I-TEQ/kg. The contribution of OCDD and OCDF in phthalocyanine green was 75% of the total TEQ. For chloranils, the maximum contribution of toxic PCDD/Fs was from 2,3,7,8-substituted HxCDF and 2,3,7,8-substituted HpCDF. The TEQ of HxCDF and HpCDF in chloranil-1 was 90% and in chloranil-2 was 71%. And the toxic contribution increased with the degree of chlorination for PCDFs.  相似文献   

14.
The deposition of atmospheric tetrachlorobenzene, pentachlorobenzene, hexachlorobenzene, α-HCH, γ-HCH, DDT, DDE and the PCB congeners 52, 101, 138, 153 and 180 to spruce needles (Picea abies) was estimated for a period of 9 months. Accumulation in spruce as a result of dry gaseous deposition, particle bound deposition and wet deposition was calculated on the basis of the corresponding deposition rates and the compounds’ concentrations in the different atmospheric compartments. The comparison of the calculated values with the concentrations of the compounds measured in 9-month-old spruce needles showed that for many compounds each deposition pathway could explain a large part of the concentrations found in the needles.  相似文献   

15.
The gas/particle partitioning of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) was measured at three sites for a year in order to monitor the variation of PCDD/Fs levels and describe their partitioning. The air concentrations of PCDD/Fs ranged from 71 to 1161 fg I-TEQ/m3 and large changes in these levels did not correlate with seasonal changes during this study. Different homolog patterns were observed in the gas/particle phase. High chlorinated dioxin/furans dominated the particle phase while low chlorinated dioxin/furans dominated the gas phase. The high correlation coefficient between log [(PCDD/Fsvap)(TSP)/(PCDD/Fspat)] and 1/T was observed in lower chlorinated dioxin/furans unlike in OCDD/F. The slope of homolog ranged from −0.410 to −1.025 and that of 2,3,7,8-substituted isomers ranged from −0.379 to −0.772 in plots of the log partition coefficient (Kp) versus the log subcooled vapor pressure (PL°).The octanol/air partition coefficient (Koa)-based model of PCDD/Fs is more compatible with experimental data than those of the Junge–Pankow model that tends to overestimate results, even though both models include some level of uncertainty. However, both models can underestimate the particle phase of PCDD/Fs, especially when the ambient air temperature is extremely low in winter.  相似文献   

16.
Part II: Persistence and Degradability of Organic Chemicals The criteria “Persistence” and “Degradability” are defined and explained, starting from the “functional” definition of the environment. In this definition, theenvironment is the counterpart of thetechnosphere, which consists of all processes controlled by man. A substance is persistent if there are no sinks (degradation processes). It is shown that persistence is the central and most important critérium of environmental hazard assessment of organic chemicals. It follows that all substances released into the environment should be degradable, preferentially into small inorganic molecules (mineralization). As examples for persistent substances, the polychlorinated biphenyls (PCB), the chlorofluorohydrocarbons (CFC), bis (2-ethylhexyl) phthalate (DEHP), and 2,3,7,8-tetrachloro-dibenzo-dioxin (TCDD) are discussed. Finally, an attempt to quantify persistence is made.  相似文献   

17.
Although polychlorinated biphenyls (PCBs) are no longer manufactured, they are still entering the environment. In some compartments of the environment, PCB concentrations are a serious concern. This is especially true in compartments which accumulate PCBs, and in food items consumed by humans and wildlife. Also, there are situations in which management decisions require rapid, sensitive, accurate measurements, which can be made in real time under field conditions. Methods to use an enzyme-linked immunosorbent assay (ELISA) for PCBs were developed and applied to sediments and fish muscle homogenates collected from the Great Lakes. The extraction methods developed can be applied in the field with non-hazardous solvents, in the absence of sophisticated laboratory equipment. The method detection limit for PCBs in dimethyl sulfoxide (DMSO) extracts of sediment was 0.9 mg/kg. For PCBs in isopropanol extracts of fish tissue, the method detection limit was 0.6 mg/kg. The resolution of the ELISA was 0.83 mg/kg at 1.1 mg/kg and 1.6 mg/kg at 1.7 mg/kg, for sediment and fish tissue, respectively.  相似文献   

18.
PCBs and PAHs in U.K. urban air   总被引:1,自引:0,他引:1  
C. Halsall  V. Burnett  B. Davis  P. Jones  C. Pettit  K.C. Jones   《Chemosphere》1993,26(12):2185-2197
As part of a long term air monitoring programme the ambient air in four UK urban areas was sampled throughout 1991. Polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) were sampled from the air in London, Cardiff, Manchester and Stevenage. Both vapour and particulate phases were collected at each site, and total concentrations are reported for 26 alternate weeks of the year.

Total PAH concentrations (sum of 15 compounds) varied between 11 and 735 ng/m3 for the four sites. For each site PAH levels were dominated by the lower molecular weight compounds of phenanthrene, fluorene and pyrene, which made up more than 75% of the ΣPAH. The contribution of individual compounds to the total was broadly similar at each site in both the winter and summer. Concentrations of the higher molecular weight compounds were greater by a factor of 2.5 in the winter months.

Eight PCB congeners (28, 52, 77, 101, 118, 138, 153 and 180) were measured at each site. London gave the highest recorded value of 3.85 ng ΣPCB/m3. Values at the four sites ranged between 0.19–3.85 ng/m3, this range being similar to levels reported in other European and American cities. Congeners 28 and 52 dominated the air mixture, comprising > 80% of the measured total. PCB concentrations in the summer were, on average, double those for the winter.  相似文献   


19.
Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were measured in bulk deposition at three Danish rural forest sites with a mutual maximum distance of 450 km. At one of the forest sites concentrations in the ambient atmosphere were sampled from a 12 m high tower. Sampling was carried out within a period of 3 years with sampling intervals of 1–2 months. Mean bulk deposition fluxes were 1 ng m−2 yr−1 I-TEQ and deviated less than 30% between the sites. Yearly average PCDD/F concentrations in the atmosphere were 24 fg m−3 I-TEQ with maximum values in the winter period. During winter months atmospheric concentrations of PCDD/F and oxidized sulphur compounds showed a positive correlation, furthermore seasonal bulk deposition showed correlation between PCDD/F and sulphate.  相似文献   

20.
Over the past decades in China, the number of medical waste incinerators (MWIs) has been rising rapidly, causing emissions of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs). In this study, samples of fly ash, ash deposits, and bottom ash from typical MWIs were analyzed for PCDD/Fs and their distribution characteristics. Results showed international toxic equivalent (I-TEQ) values in the range of 6.9–67 ng I-TEQ/g in fly ash and ash deposits, whereas the concentration in bottom ash was extremely low (only 1.33 pg I-TEQ/g), yet the generation of PCDD/Fs was mostly de novo synthesis in fly ash and ash deposits according to the ratio of PCDFs to PCDDs; the major distribution differences of PCDD/Fs in fly ash was manifested by the content of toxic furan 2,3,7,8-TCDF, but other toxic PCDD/Fs showed similar distribution. Other findings are that 2,3,4,7,8-PeCDF had the most contribution to TEQ concentration, and that the most abundant toxic furan congener is 1,2,3,4,6,7,8-HpCDF. Correlation analysis showed that there was no significant correlation between PCDD/Fs concentration and several other physical and chemical parameters.

Implications: This paper is of interest because it presents the emission performances of PCDD/Fs in ash from medical waste incineration in China. PCDD/F contents in fly ash and ash deposits vary between 6.9 and 67.3 ng I-TEQ/g. However, the concentration in bottom ash was extremely low (only 1.33?×?10?3 ng I-TEQ/g). The fingerprints of PCDD/Fs in fly ash are almost similar, except for 2,3,7,8-TCDF. There is no marked correlation between PCDD/Fs and other physicochemical properties.

Supplemental Materials: Supplemental materials are available for this paper. Go to the publisher's online edition of the Journal of the Air & Waste Management Association.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号