首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 281 毫秒
1.
The Methods Standardization Branch of the Environmental Protection Agency, National Environmental Research Center, has undertaken a program to standardize methods used in measuring air pollutants covered by the national primary and secondary air quality standards. This paper presents the results of a collaborative test of the method specified for carbon monoxide.

The test involved analysis of CO in air samples (in cylinders) by participating laboratories. Three concentrations, covering the range of the method which is, 0 to 58 mg/m3, were analyzed dry and humidified on each of three days by 15 collaborators. The method of analysis, nondispersive infrared spectrometry (NDIR), involved an NDIR instrument in combination with different procedures for eliminating water vapor interference. A statistical analysis of the data obtained produced the following results: 1. The checking limit for duplicates (replication error) is 0.5 mg/m3.

2. The repeatability (variation within a laboratory) is 1.6 mg/m3.

3. The reproducibility (variation between laboratories) varies nonlinearly with concentration; i.e., a minimum of 2.3 mg/m3 at a concentration of 20 mg/m3 and ranges as high as 4.3 mg/m3 in the concentration range of 0 to 58 mg/m3.

4. The reproducibility at the level of the national primary ambient air quality standard, 10 mg/m3-8-hour average, is 2.5 mg/m3 or 25%.

5. The minimum detectable sensitivity is estimated to be 0.3 mg/m3.

6. Compensation for water vapor interference is satisfactorily accomplished using drying agents and refrigeration methods. The use of narrow-band optical filters alone may not provide adequate compensation.

7. The accuracy obtained depends upon the availability of reliable calibration gases. Based on the results of this study, the method produces results that average 2.5% high.

Future papers will contain test results for methods to measure other air pollutants.  相似文献   

2.
The sodium arsenite method for measurement of nitrogen dioxide in ambient air was evaluated. The method has a constant-high collection efficiency (82%) for nitrogen dioxide, and is insensitive to normal variations in operating parameters. Nitric oxide and carbon dioxide are positive and negative interferents, respectively. The combined average effect of these interferents, over ambient levels, is a positive bias of 9.9 µg/m3. This bias, although statistically significant, is minor ( 10 % ) in relation to the ambient air standard of 100 µg NO2/m3 and does not warrant modification of the method to remove the interference.  相似文献   

3.
Hunt GT  Lihzis MF 《Chemosphere》2011,85(11):1664-1671
The Connecticut Department of Environmental Protection (CTDEP) commenced monitoring for PCDDs/PCDFs (polychlorinated dibenzodioxins and polychlorinated dibenzofurans) in ambient air in 1987 and adopted the long term (30 d) sampling approach in 1993. The CTDEP method represents the first use of isotopically labeled PCDDs/PCDFs as field surrogates to monitor the behavior of native PCDDs/PCDFs present in actual ambient air samples. This feature first introduced in 1987 was later adopted by US EPA in revisions to sampling methods for PCDDs/PCDFs in ambient air (EPA Method TO9A) as well as development of EPA Reference Method 23 for measurement of PCDDs/PCFDs in stationary source emissions. Results are provided here for a total of twenty-three (23) samples (reported as pairs) representing twelve (12) 30 d sampling events conducted at a site located in metropolitan Hartford CT. Samples were collected in winter months during calendar years 2002-2008. PCDDs/PCDFs concentration data (pg m−3) are reported as both congener sums (Cl4-Cl8) and 2378-substitued congeners. Total PCDDs/PCDFs concentrations for these twelve (12) sampling events ranged from 0.68 pg m−3 (2003) to 4.18 pg m−3 (2004) with a mean concentration of 2.04 pg m−3.Method performance was monitored through use of collocated samples, in field isotopically labeled compounds, isotopically labeled laboratory applied internal standards and field blank samples. Method performance consistently exceeded goals established in USEPA Method TO9A for these same parameters. Average recoveries of in field labeled PCDDs/PCDFs ranged from 97.5% to 104.2%. Average (mean) recoveries for each of the ten (10) isotopically labeled internal standards ranged from 77.0% (13C-OCDF) to 95.5% (13C-2,3,7,8-TCDF). Method precision defined as % RPD data for collocated sampler pairs ranged from 8% to 14% for PCDDs and from 5% to 12% for PCDFs. The mean RPD for all PCDDs/PCDFs combined is 9.6%. Field monitoring results demonstrate method sensitivity for all PCDDs/PCDFs congeners and 2378-substituted congeners to be well below concentrations typically found for these compounds in ambient air (all reported data represent measured concentrations). Quantities (pg) found in field blanks represent the major determinant to achieving further enhancements in method sensitivity for selected congeners (OCDD < 42 fg m−3; 1,2,3,4,6,7,8-HpCDD < 5.7 fg m−3; and 1,2,3,4,6,7,8-HpCDF < 2.1 fg m−3). The CTDEP method represents a highly sensitive and reliable technique for monitoring of PCDDs/PCDFs congeners and other persistent organic pollutants (POPs) at ultra trace levels in ambient air (fg m−3).  相似文献   

4.
The aim of the current study was to measure polycyclic aromatic hydrocarbons (PAHs) in eight indoor (In both kitchen and living room) air sampling locations using a passive sampling method for collection. Passive outdoor air samples were also collected from 3 of the same sampling locations as the indoor air sampling sites. Sampling was conducted in three seasons. The summer season, when windows are generally open, was between 18th July and 01st September, 2014; the autumn and winter seasons, when windows are mostly closed, was between 18th October and 01st December, 2014, and 01st December, 2014, and 18th January, 2015, respectively.

Average PAH concentrations in summer were 22 ± 21 ng/m3 and 17 ± 12 ng/m3 in the living room and kitchen, respectively, whereas living room and kitchen average PAH concentrations were 23 ± 16 ng/m3 and 20 ± 9 ng/m3, respectively, in autumn and 23 ± 13 ng/m3 and 23 ± 24 ng/m3, respectively, in winter. Outdoor air PAH concentrations in summer, autumn and winter were 7 ± 0.4 ng/m3, 22 ± 13 ng/m3 and 209 ± 33 ng/m3, respectively. An increase in outdoor PAH concentrations was measured in winter compared to the concentrations in summer and autumn, which paralleled the lower outdoor air temperature. However, PAH concentrations in the indoor environment vary according to the household characteristics and personal habits.  相似文献   


5.
A personal air sampling method using Amberlite XAD-2 coated with 2,4-dinitrophenylhydrazine has been developed for acrolein and glutaral dehyde. Acrolein in the 0.01 to 1.2 mg/m3 range or glutaraldehyde in the 0.03 to 3.5 mg/m3 range is easily analysed in a 5 1 air sample. Recoveries are high (80–100%), and samples stable at least for two weeks if stored in the dark until analysed.  相似文献   

6.
This study was conducted to derive receptor-specific outdoor exposure concentrations of total suspended particulate (TSP) and respirable (dae ≤ 10 µm) air manganese (air-Mn) for East Liverpool and Marietta (Ohio) in the absence of facility emissions data, but where long-term air measurements were available. Our “site-surface area emissions method” used U.S. Environmental Protection Agency’s (EPA) AERMOD (AMS/EPA Regulatory Model) dispersion model and air measurement data to estimate concentrations for residential receptor sites in the two communities. Modeled concentrations were used to create ratios between receptor points and calibrated using measured data from local air monitoring stations. Estimated outdoor air-Mn concentrations were derived for individual study subjects in both towns. The mean estimated long-term air-Mn exposure levels for total suspended particulate were 0.35 μg/m3 (geometric mean [GM]) and 0.88 μg/m3 (arithmetic mean [AM]) in East Liverpool (range: 0.014–6.32 μg/m3) and 0.17 μg/m3 (GM) and 0.21 μg/m3 (AM) in Marietta (range: 0.03–1.61 μg/m3). Modeled results compared well with averaged ambient air measurements from local air monitoring stations. Exposure to respirable Mn particulate matter (PM10; PM <10 μm) was higher in Marietta residents.

Implications: Few available studies evaluate long-term health outcomes from inhalational manganese (Mn) exposure in residential populations, due in part to challenges in measuring individual exposures. Local long-term air measurements provide the means to calibrate models used in estimating long-term exposures. Furthermore, this combination of modeling and ambient air sampling can be used to derive receptor-specific exposure estimates even in the absence of source emissions data for use in human health outcome studies.  相似文献   

7.
Concentrations of alkyllead in ambient air were measured, as well as in car exhaust and in gasoline vapours. In Oslo the concentration in air ranged from 0.010 to 0.100 μg Pb m−3, and these values were compared to the concentrations (< 0.001 μg Pb m−3) measured in a low traffic rural area of Norway. The amount of alkyllead in car exhaust varied between 0.1 and 15 μg Pb m−3, which was between 0.01 and 0.5% of the amount of inorganic lead in exhaust. Evaporation of alkyllead from parked cars was estimated at 0.5 mg Pb per day per car. The concentrations of alkyllead in saturated gasoline vapour were found to be 10–20 mg Pb m−3 at ambient air temperatures.  相似文献   

8.
Continued development of personal air pollution monitors is rapidly improving government and research capabilities for data collection. In this study, we tested the feasibility of using GPS-enabled personal exposure monitors to collect personal exposure readings and short-term daily PM2.5 measures at 15 fixed locations throughout a community. The goals were to determine the accuracy of fixed-location monitoring for approximating individual exposures compared to a centralized outdoor air pollution monitor, and to test the utility of two different personal monitors, the RTI MicroPEM V3.2 and TSI SidePak AM510. For personal samples, 24-hr mean PM2.5 concentrations were 6.93 μg/m3 (stderr = 0.15) and 8.47 μg/m3 (stderr = 0.10) for the MicroPEM and SidePak, respectively. Based on time–activity patterns from participant journals, exposures were highest while participants were outdoors (MicroPEM = 7.61 µg/m3, stderr = 1.08, SidePak = 11.85 µg/m3, stderr = 0.83) or in restaurants (MicroPEM = 7.48 µg/m3, stderr = 0.39, SidePak = 24.93 µg/m3, stderr = 0.82), and lowest when participants were exercising indoors (MicroPEM = 4.78 µg/m3, stderr = 0.23, SidePak = 5.63 µg/m3, stderr = 0.08). Mean PM2.5 at the 15 fixed locations, as measured by the SidePak, ranged from 4.71 µg/m3 (stderr = 0.23) to 12.38 µg/m3 (stderr = 0.45). By comparison, mean 24-h PM2.5 measured at the centralized outdoor monitor ranged from 2.7 to 6.7 µg/m3 during the study period. The range of average PM2.5 exposure levels estimated for each participant using the interpolated fixed-location data was 2.83 to 19.26 µg/m3 (mean = 8.3, stderr = 1.4). These estimated levels were compared with average exposure from personal samples. The fixed-location monitoring strategy was useful in identifying high air pollution microclimates throughout the county. For 7 of 10 subjects, the fixed-location monitoring strategy more closely approximated individuals’ 24-hr breathing zone exposures than did the centralized outdoor monitor. Highlights are: Individual PM2.5 exposure levels vary extensively by activity, location and time of day; fixed-location sampling more closely approximated individual exposures than a centralized outdoor monitor; and small, personal exposure monitors provide added utility for individuals, researchers, and public health professionals seeking to more accurately identify air pollution microclimates.

Implications: Personal air pollution monitoring technology is advancing rapidly. Currently, personal monitors are primarily used in research settings, but could they also support government networks of centralized outdoor monitors? In this study, we found differences in performance and practicality for two personal monitors in different monitoring scenarios. We also found that personal monitors used to collect outdoor area samples were effective at finding pollution microclimates, and more closely approximated actual individual exposure than a central monitor. Though more research is needed, there is strong potential that personal exposure monitors can improve existing monitoring networks.  相似文献   

9.
PM10 measurements were started in November 1992 at Melpitz site. The mean PM10 concentration in 1993 was 38 μg m?3 in the summer season (May until October) and about 44 μg m?3 in the winter season (November until April). The mean PM10 level decreased until 1999 and varies now in ranges from 20–34 μg m?3 to 17–24 μg m?3 (minimum and maximum mean values for 1999–2008) in winter and summer seasons, respectively. High volume filter samples of particles PM10, PM2.5 and PM1 were characterized for mass, water-soluble ions, organic and elemental carbon from 2004 until 2008. The percentage of PM2.5 in PM10 varies between summer (71.6%) and winter seasons (81.9%). Mean concentrations of PM10, PM2.5 and PM1 in Melpitz were 20, 15, and 13 μg m?3 in 2004, 22, 18, and 13 μg m?3 in 2005, 24, 19, and 12 μg m?3 in 2006 and 22, 17, and 12 μg m?3 in 2007, respectively. In the four winters the rural background concentration PM10 at Melpitz exceeded the daily 50 μg m?3 limit for Europe on 8, 8, 7 and 6 days, respectively.Findings for a simple two-sector-classification of the samples (May 2004 until April 2008) using 96-h backward trajectories for the identification of source regions are: Air masses were transported most of time (60%) from the western sector and secondly (17%) from the eastern sector. The lowest daily mean mass concentration PM10 were found during western inflow in summer (17 μg m?3) containing low amounts of sulphate (2.4 μg m?3), nitrate (1.7 μg m?3), ammonium (1.1 μg m?3) and TC (3.7 μg m?3). In opposite the highest mean mass concentration PM10 was found during eastern inflow in winter (35 μg m?3) with high amounts of sulphate (6.1 μg m?3), nitrate (5.4 μg m?3), ammonium (3.8 μg m?3) and TC (9.4 μg m?3). An estimation of secondary formed OC (SOA) shows 0.8–0.9 μg m?3 for air masses from West and 2.1–2.2 μg m?3 from East. The seasonal difference can be neglected.The half-hourly measurements of the particle mass concentration PM10 evaluated as mean daily courses using a TEOM® show low values (14–21 μg m?3) in summer and winter for air masses transported from West and the highest concentrations (31–38 μg m?3) in winter for air masses from East.The results demonstrate the influence of meteorological parameters on long-range transport, secondary particle mass formation and re-emission which modify mass concentration and composition of PM10, PM2.5 and PM1. Melpitz site is located in the East of Germany faraway from strong local anthropogenic emissions (rural background). Therefore, this site is suitable for investigation of the influence of long-range transport of air pollution in continental air masses from the East with source regions inside and outside of the European Union.  相似文献   

10.
Biofiltration is a method of biological treatment belonging to cleaner technologies because it does not produce secondary air pollutants, but helps to integrate natural processes in microorganisms for decomposing volatile air pollutants and solving odor problems. The birch wood biochar has been chosen as a principal material for biofilter bed medium. The experiments were conducted at the temperatures of 24, 28, and 32 °C, while the concentration of acetone, xylene, and ammonium reached 300 mg/m3 and the flow rate was 100 m3/hr. Before passing through the stage of the experimental research into the packing material inside biofilters, microorganisms were introduced. Four strains of microorganisms (including micromycetes Aspergillus versicolor BF-4 and Cladosporium herbarum 7KA, as well as yeast Exophiala sp. BF1 and bacterium Bacillus subtilis B20) were selected. At the inlet loading rate of 120 g/m3/hr, the highest elimination capacity of xylene in the biochar-based biofilter with the inoculated medium was 103 g/m3/hr, whereas that of ammonia was 102 g/m3/hr and that of acetone was 97 g/m3/hr, respectively. The maximum removal efficiency reached 86%, 85%, and 81%, respectively. The temperature condition (though characterized by some rapid changes) can hardly have a considerable influence on the biological effect (i.e., microbiological activity) of biofiltration; however, it can cause the changes in physical properties (e.g., solubility) of the investigated compounds.

Implications: The birch biochar can be successfully used in the biofiltration system for propagation of inoculated microorganisms, biodegrading acetone, xylene, and ammonia. At the inlet loading rate of 120 g/m3/hr, the highest elimination capacity of xylene was 103 g/m3/hr, that of ammonia was 102 g/m3/hr, and that of acetone was 97 g/m3/hr, respectively. The morphological structure of biochar can be affected by the aggressive air contaminants, causing the change in the medium specific surface area, which is one of the factors controlling the biofilter performance. Although biological effects in biofiltration are typically considered to be more important than physical effects, the former may be more important for compounds with high Henry’s Law coefficient values, and the biofilter design should thus provide conditions for better compound absorption.  相似文献   


11.
《Chemosphere》2012,86(11):1664-1671
The Connecticut Department of Environmental Protection (CTDEP) commenced monitoring for PCDDs/PCDFs (polychlorinated dibenzodioxins and polychlorinated dibenzofurans) in ambient air in 1987 and adopted the long term (30 d) sampling approach in 1993. The CTDEP method represents the first use of isotopically labeled PCDDs/PCDFs as field surrogates to monitor the behavior of native PCDDs/PCDFs present in actual ambient air samples. This feature first introduced in 1987 was later adopted by US EPA in revisions to sampling methods for PCDDs/PCDFs in ambient air (EPA Method TO9A) as well as development of EPA Reference Method 23 for measurement of PCDDs/PCFDs in stationary source emissions. Results are provided here for a total of twenty-three (23) samples (reported as pairs) representing twelve (12) 30 d sampling events conducted at a site located in metropolitan Hartford CT. Samples were collected in winter months during calendar years 2002–2008. PCDDs/PCDFs concentration data (pg m−3) are reported as both congener sums (Cl4–Cl8) and 2378-substitued congeners. Total PCDDs/PCDFs concentrations for these twelve (12) sampling events ranged from 0.68 pg m−3 (2003) to 4.18 pg m−3 (2004) with a mean concentration of 2.04 pg m−3.Method performance was monitored through use of collocated samples, in field isotopically labeled compounds, isotopically labeled laboratory applied internal standards and field blank samples. Method performance consistently exceeded goals established in USEPA Method TO9A for these same parameters. Average recoveries of in field labeled PCDDs/PCDFs ranged from 97.5% to 104.2%. Average (mean) recoveries for each of the ten (10) isotopically labeled internal standards ranged from 77.0% (13C-OCDF) to 95.5% (13C-2,3,7,8-TCDF). Method precision defined as % RPD data for collocated sampler pairs ranged from 8% to 14% for PCDDs and from 5% to 12% for PCDFs. The mean RPD for all PCDDs/PCDFs combined is 9.6%. Field monitoring results demonstrate method sensitivity for all PCDDs/PCDFs congeners and 2378-substituted congeners to be well below concentrations typically found for these compounds in ambient air (all reported data represent measured concentrations). Quantities (pg) found in field blanks represent the major determinant to achieving further enhancements in method sensitivity for selected congeners (OCDD < 42 fg m−3; 1,2,3,4,6,7,8-HpCDD < 5.7 fg m−3; and 1,2,3,4,6,7,8-HpCDF < 2.1 fg m−3). The CTDEP method represents a highly sensitive and reliable technique for monitoring of PCDDs/PCDFs congeners and other persistent organic pollutants (POPs) at ultra trace levels in ambient air (fg m−3).  相似文献   

12.
In order to investigate the chemical characteristics of atmospheric aerosol measured during a severe winter haze event, 12-hr PM2.5 (particulate matter with an aerodynamic diameter ≤2.5 μm) samples were collected at an urban site in Ulaanbaatar, Mongolia, from January 9 to February 17, 2008. On average, 12-hr PM2.5 mass concentration was 105.1 ± 34.9 μg/m3. Low PM2.5 mass concentrations were measured when low pressure developed over central Mongolia. The 12-hr average organic mass by carbon (OMC) varied from 6.4 to 132.3 μg/m3, with a mean of 54.9 ± 25.4 μg/m3, whereas elemental carbon (EC) concentration ranged from 0.1 to 3.6 μgC/m3, with a mean of 1.5 ± 0.8 μgC/m3. Ammonium sulfate was found to be the most abundant water-soluble ionic component in Ulaanbaatar during the sampling period, with an average concentration of 11.3 ± 5.0 μg/m3. In order to characterize the effect of air mass pathway on fine particulate matter characteristics, 5-day back-trajectory analysis was conducted, using the Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model. The haze level was classified into three categories, based on the 5-day air mass back trajectories, as Stagnant (ST), Continental (CT), and Low Pressure (LP) cases. PM2.5 mass concentration during the Stagnant condition was approximately 2.5 times higher than that during the Low Pressure condition, mainly due to increased pollutant concentration of OMC and secondary ammonium sulfate.

Implications: Mongolia is experiencing rapid rates of urbanization similar to other Asian countries, resulting in air pollution problems by the growing number of automobiles and industrialization. Ulaanbaatar, capital of Mongolia, is inherently vulnerable to air pollution because of its emission sources, topography, and meteorological characteristics. Very limited measurements on chemical characteristics of particulate matter have been carried out in Ulaanbaatar, Mongolia.  相似文献   

13.
Carbonaceous species (organic carbon [OC] and elemental carbon [EC]) and inorganic ions of particulate matter less than 2.5 μm (PM2.5) were measured to investigate the chemical characteristics of long-range-transported (LTP) PM2.5 at Gosan, Jeju Island, in Korea in the spring and fall of 2008–2012 (excluding 2010). On average, the non-sea-salt (nss) sulfate (4.2 µg/m3) was the most dominant species in the spring, followed by OC (2.6 µg/m3), nitrate (2.1 µg/m3), ammonium (1.7 µg/m3), and EC (0.6 µg/m3). In the fall, the nss-sulfate (4.7 µg/m3) was also the most dominant species, followed by OC (4.0 µg/m3), ammonium (1.7 µg/m3), nitrate (1.1 µg/m3), and EC (0.7 µg/m3). Both sulfate and OC were higher in the fall than in the spring, possibly due to more common northwest air masses (i.e., coming from China and Korea polluted areas) and more frequent biomass burnings in the fall. There was no clear difference in the EC between the spring and fall. The correlation between OC and EC was not strong; thus, the OC measured at Gosan was likely transported across a long distance and was not necessarily produced in a manner similar to the EC. Distinct types of LTP events (i.e., sulfate-dominant LTP versus OC-dominant LTP) were observed. In the sulfate-dominant LTP events, air masses directly arrived at Gosan without passing over the Korean Peninsula from the industrial area of China within 48 hr. During these events, the aerosol optical depth (AOD) increased to 1.63. Ionic balance data suggest that the long-range transported aerosols are acidic. In the OC-dominant LTP event, a higher residence time of air masses in Korea was observed (the air masses departing from the mainland of China arrived at the sampling site after passing Korea within 60–80 hr).

Implications:?In Northeast Asia, various natural and anthropogenic sources contribute to the complex chemical components and affect local/regional air quality and climate change. Chemical characteristics of long-range-transported (LTP) PM2.5 were investigated during spring and fall of 2008, 2009, 2011, and 2012. Based on air mass types, sulfate-dominant LTP and OC-dominant LTP were observed. A long-term variation and chemical characteristics of PM2.5 along with air mass and satellite data are required to better understand long-range-transported aerosols.  相似文献   

14.
The hexachlorocyclohexane-isomers (HCH), hexachlorobenzene (HCB), the polychlorinated biphenyls (PCB), 1,1,1-trichloro-2,2-bis(p-chlorophenyl)ethane (4,4′-DDT) and 1,1-dichloro-2,2-bis(p-chlorophenyl)ethene (4,4′-DDE) have been measured in urban and rural air around the city of Ulm (F. R. G., 48.4° N, 10.0° E). The sampling stations are typical for continental air in the westerlies of the northern hemisphere including local and regional influences. The analytical method consists of adsorptive sampling of large volumes (1000 m3) of air on silica gel, solvent desorption with CH2Cl2, preseparation of the collected chlorinated C6/C14 hydrocarbons by liquid adsorption chromatography on silica gel, and high resolution capillary gas chromatography with electron capture-(HRGC/ECD) or mass-selective detection (HRGC/MSD). The concentrations found in the lower troposphere under different meteorological conditions reflect regional input and long range transport. The levels found range from 1 pg/m3 for 4,4′-DDT to 10 ng/m3 for gamma HCH.  相似文献   

15.
This paper reports findings from a case study designed to investigate indoor and outdoor air quality in homes near the United States–Mexico border. During the field study, size-resolved continuous particulate matter (PM) concentrations were measured in six homes, while outdoor PM was simultaneously monitored at the same location in Nogales, Sonora, Mexico, during March 14–30, 2009. The purpose of the experiment was to compare PM in homes using different fuels for cooking, gas versus biomass, and to obtain a spatial distribution of outdoor PM in a region where local sources vary significantly (e.g., highway, border crossing, unpaved roads, industry). Continuous PM data were collected every 6 seconds using a valve switching system to sample indoor and outdoor air at each home location. This paper presents the indoor PM data from each home, including the relationship between indoor and outdoor PM. The meteorological conditions associated with elevated ambient PM events in the region are also discussed. Results indicate that indoor air pollution has a strong dependence on cooking fuel, with gas stoves having hourly averaged median PM3 concentrations in the range of 134 to 157 μg m?3 and biomass stoves 163 to 504 μg m?3. Outdoor PM also indicates a large spatial heterogeneity due to the presence of microscale sources and meteorological influences (median PM3: 130 to 770 μg m?3). The former is evident in the median and range of daytime PM values (median PM3: 250 μg m?3, maximum: 9411 μg m?3), while the meteorological influences appear to be dominant during nighttime periods (median PM3: 251 μg m?3, maximum: 10,846 μg m?3). The atmospheric stability is quantified for three nighttime temperature inversion episodes, which were associated with an order of magnitude increase in PM10 at the regulatory monitor in Nogales, AZ (maximum increase: 12 to 474 μg m?3).
Implications:Regulatory air quality standards are based on outdoor ambient air measurements. However, a large fraction of time is typically spent indoors where a variety of activities including cooking, heating, tobacco smoking, and cleaning can lead to elevated PM concentrations. This study investigates the influence of meteorology, outdoor PM, and indoor activities on indoor air pollution (IAP) levels in the United States–Mexico border region. Results indicate that cooking fuel type and meteorology greatly influence the IAP in homes, with biomass fuel use causing the largest increase in PM concentration.  相似文献   

16.
Neutral volatile and semi-volatile polyfluorinated organic compounds (PFC) and ionic perfluorinated compounds were determined in air samples collected at two sites in the vicinity of Hamburg, Germany, and onboard the German research vessel Atair during a cruise in the German Bight, North Sea, in early November 2007. PUF/XAD-2/PUF cartridges and glass fiber filters as sampling media were applied to collect several fluorotelomer alcohols (FTOH), fluorotelomer acrylates (FTA), perfluoroalkyl sulfonamides (FASA), and perfluoroalkyl sulfonamido ethanols (FASE) in the gas- and particle-phase as well as a set of perfluorinated carboxylates (PFCA) and sulfonates (PFSA) in the particle-phase. This study presents the distribution of PFC in ambient air of the German North Sea and in the vicinity of Hamburg for the first time. Average total PFC concentrations in and around Hamburg (180 pg m?3) were higher than those observed in the German Bight (80 pg m?3). In the German Bight, minimum–maximum gas-phase concentrations of 17–82 pg m?3 for ΣFTOH, 2.6–10 pg m?3 for ΣFTA, 10–15 pg m?3 for ΣFASA, and 2–4.4 pg m?3 for ΣFASE were determined. In the vicinity of Hamburg, minimum–maximum gas-phase concentrations of 32–204 pg m?3 for ΣFTOH, 3–26 pg m?3 for ΣFTA, 3–18 pg m?3 for ΣFASA, and 2–15 pg m?3 for ΣFASE were detected. Concentrations of perfluorinated acids were in the range of 1–11 pg m?3. FTOH clearly dominated the substance spectrum; 8:2 FTOH occurred in maximum proportions. Air mass back trajectories, cluster, and correlation analyses revealed that the air mass origin and thus medium to long range atmospheric transport was the governing parameter for the amount of PFC in ambient air. Southwesterly located source regions seemed to be responsible for elevated PFC concentrations, local sources appeared to be of minor importance.  相似文献   

17.
ABSTRACT

The effectiveness of a new emission control system in the ice resurfacer was tested in an exhaust gas emission laboratory, and the improvement of the air quality in a small, enclosed ice arena was demonstrated in a 4.5-month follow-up study. The emission control system consisted of a lambda sensor-controlled fuel supply and a three-way metallic catalyst that were applied to a propane-fueled resurfacer. In the laboratory tests, the engine emissions of carbon monoxide (CO), hydrocarbons (HC), and nitrogen oxides (NO ) reduced simultaneously by 91, 90, and 96%, respectively. During the air quality follow-up the median 1-hour average nitrogen dioxide (N02) concentration inside the ice arena decreased from 430 ug/m3 (230ppb) to 58 ug/m3 (31 ppb), and that of CO decreased from 4.4 mg/m3 (3.8 ppm) to 1.5 mg/m3 (1.3 ppm). The new emission control system proved to be a feasible, reliable, and effective means to improve the indoor air quality in the ice arena. However, continuous mechanical ventilation was necessary during all business hours in order to achieve and maintain a fully acceptable air quality with this technology.  相似文献   

18.
The current Federal EPA reference method for the determination of total suspended particulate matter (TSP) in the atmosphere is the high volume method (hi-vol).1 The hi-vol sampler is normally operated for a 24 hr period by drawing air through an 8 X 10 in. glass fiber filter at an air sampling flow rate of between 40-60 cfm. TSP samples are presently collected in this manner every 6th day (61 samples/year). Results are used to determine compliance with existing National Primary Ambient Air Quality Standards for TSP (i.e., 260 µg/m3, maximum 24 hr average, not to be exceeded more than once a year; 75 µg/m3, annual geometric mean). However, when the sampling frequency is diminished to only 61 out of a possible 365 measurements each year, the degree of certainty associated with meeting these air quality standards is also decreased.2,3 This partial sampling schedule also introduces other sampling errors. One such error caused by the exposure of the collection filter both prior and subsequent to the desired sampling day is the subject of the following discussion.  相似文献   

19.
本研究基于上向流曝气生物滤池污水处理系统,研究了该工艺不同气水比、不同水力停留时间、不同滤料高度层、反冲洗强度对污染物的处理效能的影响。结果表明,气水比为4∶1、水力停留时间2 h时,BAF出水中COD、NH+4-N和SS指标达到最佳;沿程污染物去除率随着滤料层高度的增加逐渐增大,当滤料高度大于1.6 m时趋于稳定,COD、NH+4-N和SS平均去除率分别达到80%、99%和80.3%。建议曝气生物滤池的反冲洗推荐程序为:先气冲(18 L/(m2·s)),单独气洗2~3 min;再气冲(18 L/(m2·s))加水冲(5 L/(m2·s)),联合反冲洗3~5 min;最后水冲(5 L/(m2·s)),漂洗5~8 min。  相似文献   

20.
High volume air sampling in Bermuda, Sable Island (Nova Scotia) and along a cruise track from the Gulf of Mexico to northeast coast of the USA, was carried out to assess air concentrations, particle-gas partitioning and transport of polyfluorinated chemicals (PFCs) in this region. Samples were collected in the summer of 2007. Targeted compounds included the neutral PFCs: fluorotelomer alcohols (FTOHs), perfluoroalkyl sulfonamides (FOSAs) and perfluoroalkyl sulfonamido ethanols (FOSEs).Among the FTOHs, 8:2 FTOH was dominant in all samples. Sum of the concentration of FTOHs (gas+particle phase) were higher in Bermuda (mean, 34 pg m?3) compared to Sable Island (mean, 16 pg m?3). In cruise samples, sum of FTOHs were highly variable (mean, 81 pg m?3) reflecting contributions from land-based sources in the northeast USA with concentrations reaching as high as 156 pg m?3.Among the FOSAs and FOSEs, MeFOSE was dominant in all samples. In Bermuda, levels of MeFOSE were exceptionally high (mean, 62 pg m?3), exceeding the FTOHs. Sable Island samples also exhibited the dominance of MeFOSE but at a lower concentration (mean, 15 pg m?3). MeFOSE air concentrations (pg m?3) in cruise samples ranged from 1.6 to 73 and were not linked to land-based sources. In fact high concentrations of MeFOSE observed in Bermuda were associated with air masses that originated over the Atlantic Ocean.The partitioning to particles for 8:2 FTOH, 10:2 FTOH, MeFOSE and EtFOSE ranged from as high as 15 to 42% for cruise samples to 0.9 to 14% in Bermuda. This study provides key information for validating and developing partitioning and transport models for the PFCs.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号