1.
利用球型容器与管道组合,开展连通容器气体爆炸与泄爆实验,分析连通条件下,火焰在管道中的传播过程及其对起爆容器和传爆容器的压力影响。实验结果表明:连通容器气体爆炸中,火焰从起爆容器到传爆容器传播经历了一段不断加速,但加速度不断减小的过程;泄爆过程中,火焰传播过程与密闭爆炸时基本一致。管道中火焰加速传播,使得传爆容器的爆炸压力和强度相较于作为起爆容器时均明显增加,危险更大,采用与起爆容器相同的泄爆面积,无法满足对连通容器中传爆容器的泄爆。同时,泄爆是一个快速的能量泄放过程应选择合理的泄爆方式,防止二次危害。  相似文献   

2.
建立球形容器与管道、2个球形容器与管道组成的2种形式的连通容器试验装置,研究初始压力对连通容器甲烷-空气混合物泄爆压力的影响。结果表明:连通容器内泄爆超压随初始压力增加而增大,并与初始压力近似成线性关系;对于2个球形容器与管道组成的连通容器,起爆容器的泄爆超压始终小于传爆容器;泄爆方式和点火方式对连通容器泄爆超压有较大影响,大容器点火时,2个容器的泄爆压力差随初始压力增加而增大,但小容器点火时,2个容器的泄爆压力差随初始压力的增加变化较小;初始压力对不同结构和尺寸的连通容器的泄爆压力的影响不同,当令初始压力对大容器点火时,小容器内泄爆压力受影响最大,而当对单球形容器与管道组成的连通容器的小容器点火时,小容器内泄爆压力受影响最小。  相似文献   

3.
A pilot scale interconnected vessels experiment system was established, and the closed and vented gas explosion characteristics in the system were studied, using 10% methane–air mixture. Regularity of pressure variation in vessels and flame propagation in linked pipes was analyzed. Furthermore, the effects of transmission style, ignition position, pipe length, and initial pressure on explosion severity were discussed. For the closed explosion: explosion in interconnected vessels presents strongly destructive power to secondary vessel, especially transmission from the big vessel to the small one; the worst ignition position is shifting from ignition in the interconnected pipe to the walls of the two vessels; as far as ignition in big vessel is concerned, the peak pressure in secondary vessel increases with the pipe length much faster than that for ignition in small vessel; the peak pressures in two vessels are approximate linear functions of initial pressure. For the vented explosion: the transmission style and interconnected pipe length have significant impacts on the effect of venting on the protection; in order to obtain the better venting effect, the use of a divergent interconnected pipe from the big vessel to the small one in industry is advised and it is necessary to reduce the interconnected pipe length as far as possible or install flame arrester in the interconnected pipe.  相似文献   

4.
Gas explosion in connected vessels usually leads to high pressure and high rate of pressure increase which the vessels and pipes can not tolerate. Severe human casualties and property losses may occur due to the variation characteristics of gas explosion pressure in connected vessels. To determine gas explosion strength, an experimental testing system for methane and air mixture explosion in a single vessel, in a single vessel connected a pipe and in connected vessels has been set up. The experiment apparatus consisted of two spherical vessels of 350 mm and 600 mm in diameter, three connecting pipes of 89 mm in diameter and 6 m in length. First, the results of gas explosion pressure in a single vessel and connected vessels were compared and analyzed. And then the development of gas explosion, its changing characteristics and relevant influencing factors were analyzed. When gas explosion occurs in a single vessel, the maximum explosion pressure and pressure growth rate with ignition at the center of a spherical vessel are higher than those with ignition on the inner-wall of the vessel. In conclusion, besides ignition source on the inner wall, the ignition source at the center of the vessels must be avoided to reduce the damage level. When the gas mixture is ignited in the large vessel, the maximum explosion pressure and explosion pressure rising rate in the small vessel raise. And the maximum explosion pressure and pressure rising rate in connected vessels are higher than those in the single containment vessel. So whenever possible, some isolation techniques, such as fast-acting valves, rotary valves, etc., might be applied to reduce explosion strength in the integrated system. However, when the gas mixture is ignited in the small vessel, the maximum explosion pressures in the large vessel and in the small vessel both decrease. Moreover, the explosion pressure is lower than that in the single vessel. When gas explosion happens in a single vessel connected to a pipe, the maximum explosion pressure occurs at the end of the pipe if the gas mixture is ignited in the spherical vessel. Therefore, installing a pipe into the system can reduce the maximum explosion pressure, but it also causes the explosion pressure growth rate to increase.  相似文献   

5.
To effectively prevent and mitigate explosion hazards and casualties, relief venting of flammable gas explosions has been applied in production processes in a broad variety of industries. This work conducted fully vented experiments to investigate the influence of venting membrane thickness, and partially vented experiments to investigate the influence of baffle blocking rate on the explosion characteristics of 9.5 vol% methane-air mixtures in linked vessels with a 0.5 m long vented duct. Results indicate that the membrane thickness and blocking rate for the two types of vented explosions significantly affected the explosion overpressure. The smaller the membrane thickness and blocking rate, the lower the explosion overpressure. Secondary explosions were observed in the vented duct through experiments and a weaker explosion flame appeared at a small blocking rate of 20%. With the further increase in the blocking rate, the flame became extremely weak, and no secondary explosions occurred. The overpressure evolution process at different positions in the explosion duct and secondary explosion phenomenon in the vented duct were investigated. This work could probably serve as an important reference for the selection of technical parameters of explosion venting in the practical industrial processes.  相似文献   

6.
Ducts are often recommended in the design of dust explosion venting in order to discharge materials to safe locations. However, the maximum reduced overpressure increases in a duct-vented vessel rather than in a simply vented vessel. This needs to be studied further for understanding the duct-venting mechanism. Numerous duct-vented dust explosion experiments were conducted, using a 20 L spherical chamber at elevated static activation overpressures, ranging from 1.8 bar to 6 bar. Duct diameters of 15 mm and 28 mm, and duct lengths of 0 m (simply venting), 1 m and 2 m, were selected. Explosion pressures both in the vessel and in the duct were recorded by pressure sensors, with a frequency of 5 kHz. Flame signals in the duct were also obtained by phototransistors. Results indicate that the secondary explosion occurring in the duct increases the maximum reduced overpressure in the vessel. The secondary explosion is greatly affected by the duct diameter and static activation overpressure, and hence influences the amplification of the maximum reduced overpressure. Larger static activation overpressure decreases the severity of the secondary explosion, and hence decreases the increment in the maximum reduced overpressure. The secondary pressure peak is more obvious as the pressure accumulation is easier in a duct with a smaller diameter. However, the increment of the maximum reduced overpressure is smaller because blockage effect, flame front distortion, and turbulent mixing due to secondary explosion are weaker in a narrow duct. The influence of duct length on the maximum reduced overpressure is small at elevated static activation overpressures, ranging from 1.8 bar to 6 bar at 15 mm and 28 mm duct diameters.  相似文献   

7.
A typical building consists of a number of rooms; often with windows of different size and failure pressure and obstructions in the form of furniture and décor, separated by partition walls with interconnecting doorways. Consequently, the maximum pressure developed in a gas explosion would be dependent upon the individual characteristics of the building. In this research, a large-scale experimental programme has been undertaken at the DNV GL Spadeadam Test Site to determine the effects of vent size and congestion on vented gas explosions. Thirty-eight stoichiometric natural gas/air explosions were carried out in a 182 m3 explosion chamber of L/D = 2 and KA = 1, 2, 4 and 9. Congestion was varied by placing a number of 180 mm diameter polyethylene pipes within the explosion chamber, providing a volume congestion between 0 and 5% and cross-sectional area blockages ranging between 0 and 40%. The series of tests produced peak explosion overpressures of between 70 mbar and 3.7 bar with corresponding maximum flame speeds in the range 35–395 m/s at a distance of 7 m from the ignition point. The experiments demonstrated that it is possible to generate overpressures greater than 200 mbar with volume blockages of as little as 0.57%, if there is not sufficient outflow through the inadvertent venting process. The size and failure pressure of potential vent openings, and the degree of congestion within a building, are key factors in whether or not a building will sustain structural damage following a gas explosion. Given that the average volume blockage in a room in a UK inhabited building is in the order of 17%, it is clear that without the use of large windows of low failure pressure, buildings will continue to be susceptible to significant structural damage during an accidental gas explosion.  相似文献   

8.
The coupling effects of venting and CO2 inerting on stoichiometric methane-air mixture explosions were investigated in an isolated vessel and interconnected vessels. The results indicate that venting mitigates the explosion intensity, especially for small vessels. For vessels connected by pipes, a venting design following EN 14994 (2007) and NFPA 68 (2013) could not meet the venting requirements. For an isolated big vessel and interconnected vessels, increasing the CO2 volume fraction (Φ) from 0 to 15.0 vol% decreased the maximum explosion overpressure (Pmax) and maximum rate of overpressure rise ((dP/dt)max) and delayed tmax. For closed interconnected vessels, Pmax varied approximately linearly with Φ. For both isolated vessel and interconnected vessels, the coupling effects of venting and CO2 inerting on methane-air explosion were more efficient than those of individual mitigative method (that is, venting alone or CO2 inerting alone).  相似文献   

9.
柱形压力容器开口泄爆过程数值模拟研究   总被引:4,自引:1,他引:3  
为研究柱形压力容器泄爆规律,采用经典流体力学软件FLUENT对典型的柱形压力容器泄爆过程进行数值模拟,分析从泄爆口开启到泄压结束时间段压力发展、火焰传播、气体流动及可燃气体浓度变化特性。结果表明:不同泄爆压力下容器内压力发展变化呈现不同特点,在较小泄爆压力情况下会出现压力再度上升的双峰现象。泄爆过程中产生的湍流沿泄爆口附近容器壁拉长火焰面,并加快燃烧速率。同时就容器内不同点火位置对爆炸强度影响进行研究,得出在泄爆压力为0.04 MPa时,底面点火对本柱形压力容器产生的最大升压速率约为中心点火最大升压速率的1.4倍。  相似文献   

10.
Multi-component gas mixture explosion accidents occur and recur frequently, while the safety issues of multi-component gas mixture explosion for hydrogen–methane mixtures have rarely been addressed.Numerical simulation study on the confined and vented explosion characteristics of methane-hydrogen mixture in stoichiometric air was conducted both in the 5 L vessel and the 64 m3 chamber, involving different mixture compositions and initial pressures. Based on the results and analysis, it is shown that the addition of hydrogen has a negative effect on the explosion pressure of methane-hydrogen mixture at adiabatic condition. While in the vented explosion, the addition of the hydrogen has a significant positive effect on the explosion hazard degree. Additionally, the addition of hydrogen can induce a faster reactivity and enhance the sensitivity of the mixture by reducing the explosion time and increasing the rate of pressure rise both in confined and vented explosion. Both the maximum pressure and the maximum rate of pressure rise increase with initial pressure as a linear function, and also rise with the increase of hydrogen content in fuel. The increase in the maximum rate of pressure rise is slight when hydrogen ratio is lower than 0.5, however, it become significant when hydrogen ratio is higher than 0.5. The maximum rate of pressure rise for stoichiometric hydrogen-air is about 10 times the one of stoichiometric methane-air.Furthermore, the vent plays an important role to relief pressure, causing the decrease in explosion pressure and rate of pressure rise, while it can greatly enhance the flame speed, which will extend the hazard range and induce secondary fire damages. Additionally it appears that the addition of hydrogen has a significant increasing effect on the flame speed. The propagation of flame speed in confined explosion can be divided into two stages, increase stage and decrease stage, higher hydrogen content, higher slope. But in the vented explosion, the flame speed keeps increasing with the distance from the ignition point.  相似文献   

11.
A 20 L spherical explosive device with a venting diameter of 110 mm was used to study the vented pressure and flame propagation characteristics of corn dust explosion with an activation pressure of 0.78–2.1 bar and a dust concentration of 400∼900 g/m3. And the formation and prevention of secondary vented flame are analyzed and discussed. The results show that the maximum reduced explosion overpressure increases with the activation pressure, and the vented flame length and propagation speed increase first and then decrease with time. The pressure and flame venting process models are established, and the region where the secondary flame occurs is predicted. Whether there is pressure accompanying or not in the venting process, the flame venting process is divided into two stages: overpressure venting and normal pressure venting. In the overpressure venting stage, the flame shape gradually changes from under-expanded jet flame to turbulent jet flame. In the normal pressure venting stage, the flame form is a turbulent combustion flame, and a secondary flame occurs under certain conditions. The bleed flames within the test range are divided into three regions and four types according to the shape of the flame and whether there is a secondary flame. The analysis found that when the activation pressure is 0.78 bar and the dust concentration is less than 500 g/m3, there will be no secondary flame. Therefore, to prevent secondary flames, it is necessary to reduce the activation pressure and dust concentration. When the dust concentration is greater than 600 g/m3, the critical dust concentration of the secondary flame gradually increases with the increase of the activation pressure. Therefore, when the dust concentration is not controllable, a higher activation pressure can be selected based on comprehensive consideration of the activation pressure and destruction pressure of the device to prevent the occurrence of the secondary flame.  相似文献   

12.
Explosion venting is a frequently-used way to lower explosion pressure and accident loss. Recently, studies of vessel explosion venting have received much attention, while little attention has been paid to pipe explosion venting. This study researched the characteristics of explosion venting for Coal Bed Methane (CBM) transfer pipe, and proposed the way of explosion venting to chamber in order to avoid the influence of explosion venting on external environment, and investigated the effects of explosion venting to atmosphere and chamber. When explosion venting to atmosphere, the average explosion impulse 4.89 kPa s; when explosion venting to 0 MPa (atmospheric pressure) chamber, average explosion impulse is 7.52 kPa s; when explosion venting to −0.01 MPa chamber, explosion flame and pressure obviously drop, and average explosion impulse decreases to 4.08 kPa s; when explosion venting to −0.09 MPa chamber, explosion flame goes out and average explosion impulse is 1.45 kPa s. Thus, the effect of explosion venting to negative chamber is far better than that to atmospheric chamber. Negative chamber can absorb more explosion gas and energy, increase stretch of explosion flame, and eliminate free radical of gas explosion. All these can promote the effect of explosion venting to negative chamber.  相似文献   

13.
To investigate the effects of cylinders placed parallel to the venting direction on the structural response of the vessel walls to an explosion, 25 batches of vented explosion tests were conducted in a 1 m3 rectangular vessel. Two types of structural response with different amplitudes and frequency distributions were observed and evaluated by comparing the vibration data with both the pressure data and high-speed videos. A low-amplitude structural response of approximately 150–250 m/s2, which increased slightly as VBR increased, was triggered by a combination of the initial flame propagation, external explosion, Helmholtz oscillations, and the Taylor instability. A high-amplitude structural response of approximately 9500 m/s2 was also observed, which decreased sharply as VBR increased. Additionally, the high amplitude response was never observed when more than two cylinders were present in the vessel. The high amplitude response was triggered due to the coupling between the acoustic wave, the flame, and the resonance of the vessel. The presence of obstacles did not increase the severity of the structural responses under the current experimental conditions. To the contrary, the presence of obstacles in the container attenuated or even inhibited the high-amplitude vibration of the container caused by the explosion.  相似文献   

14.
Explosion venting is widely applied in industrial explosion-proof designs due to the convenient, economical and practical features of this method. Natural gas is usually stored in storage tanks. If the gas in the vessel is mixed with air and encounters an ignition source, explosion venting might occur, producing jet fire, generating new secondary derivative accidents and causing casualties and property losses. In this paper, a set of test platforms including wire-mesh suppression devices is established to study the inhibition of jet fire induced by explosion venting by wire mesh. The experimental research shows that a wire mesh significantly inhibits the jet fire induced by explosion venting. The flame propagation velocity and pressure clearly decrease with increasing numbers of wire-mesh layers. The wire-mesh structure significantly affects the flame propagation, and the more layers of mesh there are, the better the suppression effect is. The flame temperature gradually decreases with the addition of the wire mesh. The mesh size significantly affects the pressure propagation of explosion venting. The explosion pressure gradually decreases with the addition of the wire mesh. With increasing distance between the wire mesh and the explosion vent, the maximum temperature first increases and then decreases, and the maximum explosion pressure first decreases and then increases. In the case of single gas cloud, the flame suppression effect is the most obvious when the wire mesh is 0.2 m away from the explosion vent. In the case of double gas clouds, the flame suppression effect is the most significant when the distance between the wire mesh and the first gas cloud is 0.4 m.  相似文献   

15.
In the present work, a series of experiments have been performed to analyze the explosion characteristics of ethanol-gasoline with various blended ratios (0%, 5%, 10%, 15%, 30%, 50%, 70%, 80%, and 100%). A vented rectangular vessel with a cross-section of 100 mm × 100 mm, 600 mm long and a 40 mm diameter vent on the top is used to carry out the experiments. The flame propagation is recorded by a phantom high-speed camera with 5000 fps, while the histories of the explosion overpressure are measured by two PCB pressure sensors and the explosion sound pressure level is obtained by a CRY sound sensor. The results indicate that the maximum overpressure and flame propagation speed increases linearly as the blended ratio increases when the initial volume of blended fuel is 1.0 mL; While the change of explosion overpressure and flame propagation speed shows a trend of decreasing at first and then increasing as the concentration increases to 1.8 mL. It is also found that the peak of the sound pressure level exceeds 100 dB under all tests, which would damage the human's hearing. What's more, relationships between explosion overpressure and sound pressure level are examined, and the change of the maximum overpressure can be reflected to some extent by the measurement of the maximum sound pressure level. The study is significant to reveal the essential characteristic of the explosion venting process of ethanol-gasoline under different initial blended ratios, and the results would help deepen the understanding of ethanol-gasoline blended fuels explosion and the assessment of the explosion hazardous.  相似文献   

16.
A study on the obstacle-induced variation of the gas explosion characteristics   总被引:13,自引:0,他引:13  
A study on the variation of the gas explosion characteristics caused by the built-in obstacles was conducted in enclosed/vented gas explosion vessels. It has been well known that the obstacles in pipes and long ducts would accelerate the flame propagation, and cause the transition from deflagration to detonation. In this study, the explosion characteristics and the flame behavior of vented explosions and constant-volume explosions were investigated. Experiments were carried out in a 270-liter and 36-liter hexahedron vessels filled with LPG–air mixture. The explosion characteristics of the gas mixture were determined by using a strain-responding pressure transducer. The flame behavior was recorded by using a high-speed video camera. The shape and the size of the obstacle, and the gas concentration, were adjusted in the experiments.

It can be seen from the experimental results that, instead of being accelerated, the flame propagation inside the explosion vessel is decelerated by the plate obstacles fixed at the bottom of the vessel. Also, the characteristics of the enclosed explosion are not so affected by the built-in obstacles as those of the vented explosion are. It is believed that the eddy-induced turbulence behind the obstacle decelerates the flame propagation.  相似文献   


17.
为了解尺寸对球形容器连接管道甲烷-空气混合物爆炸的影响规律,利用Fluent软件,采用κ-ε湍流模型、涡耗散模型(简称EDC模型)、壁面热耗散、热辐射模型及SIMPLE算法,建立了球形容器连接管道内甲烷-空气混合物爆炸的数值模型,对容器与管道内甲烷-空气预混气体爆炸的尺寸效应进行了数值模拟。结果表明:随管道内径增大,球形容器内最大爆炸压力逐渐增大,管道末端最大爆炸压力变化无明显规律;而随管道长度增加,球形容器内最大爆炸压力逐渐减小;改变管道内径,较大体积球形容器内最大爆炸压力均大于较小体积球形容器内最大爆炸压力,最大爆炸压力上升速率的规律则相反,容器体积对管道末端最大爆炸压力的影响无明显规律。  相似文献   

18.
对甲烷-空气预混气体在球形容器和球形管道连通容器内的泄爆过程进行实验研究,根据实验结果得出在较小的泄压面积时,与密闭容器爆炸实验比较,不能降低容器内的最大压力,反而会增大容器内的最大压力。通过实验结果分析,泄爆口安装在远离点火源的位置,当发生预混气体爆炸时能较好地降低容器内的最大压力,起到保护容器的作用。  相似文献   

19.
The paper outlines an experimental study on influence of the spark duration and the vessel volume on explosion parameters of premixed methane–air mixtures in the closed explosion vessels. The main findings from these experiments are: For the weaker ignition the spark durations in the range from 6.5 μs to 40.6 μs had little impact on explosion parameters for premixed methane–air mixtures in the 5 L vessel or 20 L vessel; For the same ignitions and volume fractions of methane in air the explosion pressures and the flame temperatures in both vessels of 5 L and 20 L were approximately the same, but the rates of pressure rises in both vessels of 5 L and 20 L were different; The explosion indexes obtained from the measured pressure time histories for both vessels of 5 L and 20 L were approximately equal; For the weaker ignition with the fixed spark duration 45 μs the ignition energies in the range from 54 mJ to 430 mJ had little impact on the explosion parameters; For the same ignition and the volume fractions of methane in air, the vessel volumes had a significant impact on the flame temperatures near the vessel wall; The flame temperatures near the vessel wall decreased as the vessel volumes increased.  相似文献   

20.
The explosion of flammable mixtures in interconnected compartments is commonly defined as “pressure piling”. Peak pressures much higher than the predictable thermodynamic values are likely to be generated in this geometry, yielding the phenomenon of major interest in industrial safety. In this paper, a CFD model was implemented, aiming at understanding the major factors affecting pressure piling in two cylindrical interconnected vessels, by varying the volume ratio between the two interconnected vessels and the ignition position. A combustion model was specifically developed to follow the flame propagation in any combustion regimes as a function of the local conditions: laminar, flamelet and distributed reaction zone.The model was validated by comparison with experimental results. The agreement between the experiments and the simulations has allowed the interpretation of the pressure piling phenomenon and the understanding of the mechanisms involved. More precisely, the results have showed that the pressure peak intensity is mainly affected by the coupling between the pre-compression of the mixture in the secondary vessel and the violence of explosion in the same vessel as related to the venting time, the latest quantified by the turbulent Bradley number, Brt i.e. by the reaction time to the venting time ratio.  相似文献   