The odour impact of a composting plant situated in an urbanized area was evaluated by continuously monitoring the ambient air close to the plant during a period of about 4 days using two electronic noses. One electronic nose was installed in a nearby house, and the other one inside the perimeter of the composting plant in order to compare the response of both instruments. The results of the monitoring are represented by tables that report the olfactory class and the odour concentration value attributed to the analyzed air for each of the 370 measurements carried out during the monitoring period. The electronic nose installed at the house detected the presence of odours coming from the composting plant for about 7.8% of the monitoring total duration. Of the odour detections, 86% (25 of 29 measurements) were classified as belonging to the olfactory class corresponding to the open air storage of the waste screening overflows heaps, which was therefore identified to be the major odour source of the monitored composting plant. In correspondence of the measurements during which the electronic nose inside the house detected the presence of odours from the composting plant, the olfactory classes recognized by both instruments coincide. Moreover, the electronic nose at the house detected the presence of odours from the composting plant at issue in correspondence of each odour perception of the house occupants. The results of the study show the possibility of using an electronic nose for environmental odours monitoring, which enables the classification of the quality of the air and to quantify the olfactory nuisance from an industrial source in terms of duration and odour concentration.  相似文献   

2.
The treatment of waste and many manufacturing processes cause odour emissions. In order to prevent odours, the residents and businesses in the neighbourhood of such plants complain about odour, and it becomes necessary to reduce the emissions. To achieve that, the emissions have to be investigated and evaluated in a representative and reproducible manner. The DIN EN 13725 (2003) [DIN EN 13725. 2003. Luftbeschaffenheit--Bestimmung der Geruchsstoffkonzentration mit dynamischer Olfaktometrie--Air quality--Determination of odour concentration by dynamic olfactometry, Deutsche Fassung EN 13725:2003. Beuth Verlag, Berlin (DE)] provides a European standard for the measurement of odour. Nevertheless, the subject of sampling is not standardised; even though it has a substantial influence on the results of the measurements. In this paper, the odour measurement itself, as well as the different kinds of sampling methods (depending on the specific type of source), will be presented and discussed.  相似文献   

3.
Effects of pH and microbial composition on odour in food waste composting   总被引:1,自引:0,他引:1  
A major problem for composting plants is odour emission. Slow decomposition during prolonged low-pH conditions is a frequent process problem in food waste composting. The aim was to investigate correlations between low pH, odour and microbial composition during food waste composting. Samples from laboratory composting experiments and two large scale composting plants were analysed for odour by olfactometry, as well as physico-chemical and microbial composition. There was large variation in odour, and samples clustered in two groups, one with low odour and high pH (above 6.5), the other with high odour and low pH (below 6.0). The low-odour samples were significantly drier, had lower nitrate and TVOC concentrations and no detectable organic acids. Samples of both groups were dominated by Bacillales or Actinobacteria, organisms which are often indicative of well-functioning composting processes, but the high-odour group DNA sequences were similar to those of anaerobic or facultatively anaerobic species, not to typical thermophilic composting species. High-odour samples also contained Lactobacteria and Clostridia, known to produce odorous substances. A proposed odour reduction strategy is to rapidly overcome the low pH phase, through high initial aeration rates and the use of additives such as recycled compost.  相似文献   

4.
If residents’ perceptions, concerns and attitudes towards waste management facilities are either not well understood or underestimated, people can produce strong opposition that may include protest demonstrations and violent conflicts such as those experienced in the Campania Region of Italy. The aim of this study was to verify the effects of the closure of solid waste treatment and disposal facilities (two landfills and one RDF production plant) on public perception of odour and environmental pollution. The study took place in four villages in Southern Italy. Identical questionnaires were administered to residents during 2003 and after the closure of the facilities occurred in 2008. The residents’ perception of odour nuisance considerably diminished between 2003 and 2009 for the nearest villages, with odour perception showing an association with distance from the facilities. Post closure, residents had difficulty in identifying the type of smell due to the decrease in odour level. During both surveys, older residents reported most concern about the potentially adverse health impacts of long-term exposure to odours from MSW facilities. However, although awareness of MSW facilities and concern about potentially adverse health impacts varied according to the characteristics of residents in 2003, substantial media coverage produced an equalisation effect and increased knowledge about the type of facilities and how they operated. It is possible that residents of the village nearest to the facilities reported lower awareness of and concern about odour and environmental pollution because the municipality received economic compensation for their presence.  相似文献   

5.
Unpleasant odours generated from waste management facilities represent an environmental and societal concern. This multi-year study documented odour and total reduced sulfur (TRS) abatement in four experimental landfill biocovers installed on the final cover of the Saint-Nicéphore landfill (Canada). Performance was evaluated based on the reduction in odour and TRS concentrations between the raw biogas collected from a dedicated well and the emitted gases at the surface. Odour analyses were carried out by the sensorial technique of olfactometry, whereas TRS analyses followed the pulse fluorescence technique. The large difference of 2–5 orders of magnitude between raw biogas (average odour concentration = 2,100,000 OU m?3) and emitted gases resulted in odour removal efficiencies of close to 100% for all observations. With respect to TRS concentrations, abatement efficiencies were all greater than 95%, with values averaging 21,000 ppb of eq. SO2 in the raw biogas. The influence of water infiltration on odour concentrations was documented and showed that lower odour values were obtained when the 48-h accumulated precipitation prior to sampling was higher.  相似文献   

6.
Municipal solid waste treatment facilities are generally faced with odorous nuisance problems. Characterizing and determining the odorous charge of indoor air through odour units (OU) is an advantageous approach to evaluate indoor air quality and discomfort. The assessment of the OU can be done through the determination of volatile organic compounds (VOCs) concentrations and the knowledge of their odour thresholds. The evaluation of the presented methodology was done in a mechanical–biological waste treatment plant with a processing capacity of 245.000 tons year?1 of municipal residues. The sampling was carried out in five indoor selected locations of the plant (Platform of Rotating Biostabilizers, Shipping warehouse, Composting tunnels, Digest centrifugals, and Humid pre-treatment) during the month of July 2011. VOC and volatile sulphur compounds (VSCs) were sampled using multi-sorbent bed (Carbotrap, Carbopack X, Carboxen 569) and Tenax TA tubes, respectively, with SKC AirCheck 2000 pumps. The analysis was performed by automatic thermal desorption (ATD) coupled with a capillary gas chromatography (GC)/mass spectrometry detector (MSD). One hundred and thirty chemical compounds were determined qualitatively in all the studied points (mainly alkanes, aromatic hydrocarbons, alcohols, aldehydes, esters, and terpenes), from which 86 were quantified due to their odorous characteristics as well as their potentiality of having negative health effects. The application of the present methodology in a municipal solid waste treatment facility has proven to be useful in order to determine which type of VOC contribute substantially to the indoor air odorous charge, and thus it can be a helpful method to prevent the generation of these compounds during the treatment process, as well as to find a solution in order to suppress them.  相似文献   

7.
Odour management and treatment technologies: an overview   总被引:4,自引:0,他引:4  
There is a large variety of options available for the effective treatment of odorous emissions. The most important physical, chemical and biological treatment processes are shortly described and their favourable applications, as well as their limits, are highlighted. But for a sustainable solution of an industrial odour problem, there is more involved than just the installation of a waste gas treatment system. This article focuses on a general and systematic approach towards extensive odour management. First of all, an odour assessment should be worked out where all actual and potential odour emission sources are recorded and characterised. A special focus should be set on fugitive emissions, which may have an enormous impact on the overall odour problem. They need to be captured before they can be supplied to a treatment system. According to the composition and condition of the waste gases, an appropriate treatment system must be selected. For this purpose, test systems have been developed and are presented in this article.  相似文献   

8.
Compost sustainability requires a better control of its gaseous emissions responsible for several impacts including odours. Indeed, composting odours have stopped the operation of many platforms and prevented the installation of others. Accordingly, present technologies collecting and treating gases emitted from composting are not satisfactory and alternative solutions must be found. Thus, the aim of this paper was to study the influence of composting process conditions on gaseous emissions. Pig slaughterhouse sludge mixed with wood chips was composted under forced aeration in 300 L laboratory reactors. The process conditions studied were: aeration rate of 1.68, 4.03, 6.22, 9.80 and 13.44 L/h/kg of wet sludge; incorporation ratio of 0.55, 0.83 and 1.1 (kg of wet wood chips/kg of wet sludge), and; bulking agent particles size of <10, 10 < 20 and 20 < 30 mm. Out-going gases were sampled every 2 days and their composition was analysed using gas chromatography coupled with mass spectrometry (GC–MS). Fifty-nine compounds were identified and quantified. Dividing the cumulated mass production over 30 days of composting, by odour threshold, 9 compounds were identified as main potential odour contributors: hydrogen sulphide, trimethylamine, ammonia, 2-pentanone, 1-propanol-2-methyl, dimethyl sulphide, dimethyl disulphide, dimethyl trisulphide and acetophenone. Five gaseous compounds were correlated with both aeration rate and bulking agent to waste ratio: hydrogen sulphide, trimethylamine, ammonia, 2-pentanone and 1-propanol-2-methyl. However, dropping the aeration rate and increasing the bulking agent to waste ratio reduced gaseous odour emissions by a factor of 5–10, when the required threshold dilution factor ranged from 105 to 106, to avoid nuisance at peak emission rates. Process influence on emissions of dimethyl sulphide, dimethyl disulphide, dimethyl trisulphide were poorly correlated with both aeration rate and bulking agent to waste ratio as a reaction with hydrogen sulphide was suspected. Acetophenone emissions originated from the wood chips. Olfactory measurements need to be correlated to gaseous emissions for a more accurate odour emission evaluation.  相似文献   

9.
Nuisance caused by odors is one of the most important problems for waste management plants. To control an odor nuisance, it must first be quantified. The analytical difficulties in odor measurements are related to the high number of volatile components (belonging to several chemical classes), above all when the concentration is lower than the detection limit of the technique used for the measurement. In this work, 2-butanone, alpha-pinene, tetrachloroethylene, dimethyldisulfide, beta-pinene, limonene, phenol and benzoic acid are determined, because they are representative of some important classes of compounds with higher odor impact. The compounds are sampled with thermal desorbable radial diffusive samplers Radiello containing Tenax cartridges. The analytical repeatability and the complete thermal desorption of the cartridges were verified for each odor compound; the relative standard deviations for repeated samples and the recovery percentage were, respectively, less than 7% and about 97% for all compounds. The measurements of the linearity of sampling showed no systematic difference according to the collection period. The comparison between the odor threshold and the limit of detection demonstrated that this method is reliable for the recognition and quantification of odor compounds, allowing Public Administration to impose legal limits and the control agencies to verify them.  相似文献   

10.
Bioaerosols (microbes, dust and endotoxins) and volatile organic compounds (VOCs) were determined in the working air of a drum composting plant treating source-separated catering waste. Different composting activities at the Oulu drum composting plant take place in their own units separated by modular design and constructions. Important implication of this is that the control room is a relatively clean working environment and the risk of exposure to harmful factors is low. However, the number of viable airborne microbes was high both in the biowaste receiving hall and in the drum composting hall. The concentration (geometric average) of total microbes was 21.8 million pcs/m3 in the biowaste receiving hall, 13.9 million pcs/m3 in the drum composting hall, and just 1.4 million pcs/m3 in the control room. Endotoxin concentrations were high in the biowaste receiving hall and in the drum composting hall. The average (arithmetic) endotoxin concentration was over the threshold value of 200 EU/m3 in both measurement locations. In all working areas, the average (arithmetic) dust concentrations were in a low range of 0.6-0.7 mg/m3, being below the Finnish threshold value of 5 mg/m3. In the receiving hall and drum composting hall, the concentrations of airborne microbes and endotoxins may rise to levels hazardous to health during prolonged exposure. It is advisable to use a respirator mask (class P3) in these areas. Detected volatile organic compounds were typical compounds of composting plants: carboxylic acids and their esters, alcohols, ketones, aldehydes, and terpenes. Concentrations of VOCs were much lower than the Finnish threshold limit values (Finnish TLVs), many of the quantified compounds exceeded their threshold odour concentrations (TOCs). Primary health effects due VOCs were not presumable at these concentrations but unpleasant odours may cause secondary symptoms such as nausea and hypersensitivity reactions. This situation is typical of composting plants where the workers are exposed to dozens of VOCs simultaneously. The odour units (OU/m3) were measured using olfactometer. The numbers were 23,000 OU/m3 at the output end of the composting drum and 6300 OU/m3 in the exhaust pipe. Inside the composting hall, the number of odour units was 500 and 560 OU/m3.  相似文献   

11.
Investigations regarding the reduction of airborne germs in the waste gas of biowaste composting processes have been carried out at the Hamburg University of Science and Technology and the University of Leipzig. Numerous waste gas treatment plants, ranging from laboratory-scale to technical-scale, have been available at the institutes of these two project partners. All plants consisted of bioscrubber/biofilter combinations. The results showed that these biological systems designed for odour control are able to successfully reduce bioaerosol emissions, even though a reduction to background levels could not be achieved. The bioscrubber, if equipped with a droplet separator, proved to be mainly responsible for the reduction, whereas the biofilter acted as a source for microbial emissions originating from the filter material. It could be observed that the microbial population changed while passing the treatment system, indicating the ability of biological waste gas treatment systems to retain potentially pathogenic microorganisms from waste gases.  相似文献   

12.
The biofilter and the ionisation system are two oxidative treatment techniques for purification of waste gas streams with low concentrations of volatile organic compounds. In this paper, the authors present the investigations of an ionisation technique aimed at increasing the efficiency of the reduction of the odorant concentration in waste gas streams from biological waste treatment plants. The objective is to enable advanced odour emission reduction and to adjust the existing biofilters to stricter requirements. In a first step, the odorous substances which are major contributors to the overall odorant concentration are identified on basis of various emission data sets with the help of a method of life cycle impact assessment. Thereby limonene, alpha-pinene, ethyl butyrate and dimethyl disulphide were identified as crucial indicators. In a second step, experimental investigations using limonene as a model compound were conducted to gain an understanding of the ionisation process itself and at last for the evaluation of the system.  相似文献   

13.
Increased nutrient loading of a body of water leads to an increase in macroalgal growth. It is generally observed, however, that certain species thrive more than others, capitalising on the increased nutrient availability. These are usually small, fast-growing, ephemeral algae that often appear as nuisance blooms. This article discusses the correlation between nutrient increase and macroalgal bloom formation. From a historical perspective, the evolutionary history of nuisance macroalgae, and the habits available to them prior to anthropogenic influences on estuarine geochemistry are considered. The occurrence of macroalgal genera whose distribution is commonly related to estuaries with high nutrient loading is discussed, along with evidence suggesting that the ecophysiological traits of r-selected, ephemeral algae largely contribute to their ecological success and bloom-formation at nutrient-enriched sites.  相似文献   

14.
Shredder residues produced in plants processing waste electric and electronic equipment are excluded from material recycling due to a variety of polymeric materials and the presence of brominated flame retardants (BFR), which might contain banned polybrominated diphenyl ethers or toxic polybrominated dioxins and furans (PBDD/F). Herein we present a technological approach to transfer a significant portion of the shredder residue into recycled polymers. The technological approach consists of a density-based enrichment of styrenics, which are subjected to a solvolysis process (CreaSolv process) in a second stage. This stage allows the elimination of non-target polymers and extraction of BFR and PBDD/F. Pilot processing of 11.5 and 50 kg shredder residues indicated a material yield of about 50% in the density stage and 70-80% in the CreaSolv process, and an effective removal of BFR additives. The recycled products were proved to comply with threshold values defined by the European directive on the restriction of hazardous substances (RoHS) and the German Chemikalienverbotsverordnung. Mechanical material properties exhibited high tensile and flexural modules as well as slight impact strength, which qualify the products for applications in new electronic equipment.  相似文献   

15.
In the present study, we investigated the effects of two bulking materials, Sphagnum peat and pine wood chips, on the early stages of biowaste composting in two pilot-scale processes. Emphasis was placed on studying the formation conditions of malodorous compost gases in the initial phases of the processes. The results showed that gas emission leaving an open windrow and a closed drum composting system contained elevated concentrations of fermentative microbial metabolites when acid Sphagnum peat (pH 3.2) was used as a bulking material. Moreover, the gas emission of the peat amended drum composter contained a high concentration of odour (up to 450,000 ou m?3 of air). The highest odour values in the outlet gas of peat amended composts coincided with the elevated concentrations of volatile organic compounds such as acetoin and buthanedion. We conclude that the acidifying qualities of composting substrates or bulking material may intensify odour emission from biowaste composts and prolong the early stages of the composting process.  相似文献   

16.
Evaluation of sites for the location of WEEE recycling plants in Spain   总被引:1,自引:0,他引:1  
As a consequence of new European legal regulations for treatment of waste electrical and electronic equipment (WEEE), recycling plants have to be installed in Spain. In this context, this contribution describes a method for ranking of Spanish municipalities according to their appropriateness for the installation of these plants. In order to rank the alternatives, the discrete multi-criteria decision method PROMETHEE (Preference Ranking Organisation METHod for Enrichment Evaluations), combined with a surveys of experts, is applied. As existing plants are located in North and East Spain, a significant concentration of top ranking municipalities can be observed in South and Central Spain. The method does not present an optimal structure of the future recycling system, but provides a selection of good alternatives for potential locations of recycling plants.  相似文献   

17.
Accident risks in waste treatment were studied at five sanitary landfills, two plants using mainly manual sorting and one incineration plant in southern Finland. Work hazards were detected by means of safety analysis. In addition, accident statistics were used. Work safety problems were found at all work stages. At the sanitary landfills, the major safety problems were posed by operation of the compactor or other machinery and by hazardous wastes. In waste sorting, common problems are odour and dust, lacerations and back injuries. Falling into the waste compactor or paper silos may cause fatal injury and its probability was also high. The highest noise level measured was 97 dB(A). In waste incineration, the most serious hazards were caused by fires, clogging of the funnels and cleaning of the grate. Most deficiencies in work safety can be remedied at a moderate price. The corrective measures involve technical solutions, working methods, supervision, training and occupational health services. The accident rates for workers in the four waste treatment plants were slightly lower than the average for industry.  相似文献   

18.
Odour control at biowaste composting facilities   总被引:7,自引:0,他引:7  
There are several options to effectively reduce odorous emissions at composting facilities depending on the type of composting system used. Some of the more relevant measures for open and enclosed composting facilities are presented in this article. Results from different investigations on odour reduction efficiencies of biological waste gas treatment systems at various scales are presented. Biofilter/bioscrubber combinations were used and different biofilter materials were tested. The more relevant odorous substances in the waste gas were identified, and their reduction in the different systems was measured. The biofilter proved to be mainly responsible for efficient odour degradation. The investigations presented in this article revealed that screened compost was very effective, and proved to be a low cost biofilter material for odour degradation purposes. Screened compost showed higher degradation rates than a coke-compost mixture newly developed by the University of Leipzig. Furthermore, it seems that enclosed systems have advantages when compared to conventional open single bed biofilters.  相似文献   

19.
Water-soluble extracts from compost may represent an alternative nutrient and organic matter source for crop production under drip irrigation. Dissolved organic matter (DOM), extracted from composted "alperujo", the main by-product from the Spanish olive oil industry, was applied to soil alone or in combination with either Glomus intraradices Schenck and Smith or a mixture of G. intraradices, Glomus deserticola (Trappe, Bloss. and Menge) and Glomus mosseae (Nicol and Gerd.) Gerd. and Trappe. Response measurements included mycorrhizal colonisation, nutrient uptake and growth of Medicago sativa and microbiological and physical properties in the rhizosphere. Dissolved organic matter was added to soil at concentrations of 0, 50, 100 or 300mgCkg(-1) substrate. During the four months of the experiment, the plants were harvested three times. Both mycorrhizal inoculation treatments significantly increased soil aggregate stability. Only the mycorrhizal inoculations increased microbial biomass C and protease and phosphatase activities and decreased water-soluble C, particularly the mixture of arbuscular mycorrhizal fungi. At the third harvest, the greatest increase in growth of M. sativa was observed in the inoculated plants with shoot biomass being 38% greater than for plants grown in the soil amended with the highest dose of DOM and 57% greater than for control plants. The addition of DOM was not sufficient to restore soil structure and microbial activity and did not affect the mycorrhizal development of introduced populations of arbuscular mycorrhizal fungi, but, depending on the dose, its fertiliser efficiency for improving plant growth was apparent.  相似文献   

20.
This paper presents a case study of a Long Island. New York, landfill where methane and VOC gases were migrating off-site. The municipally owned and operated Port Washington Landfill located adjacent to residential housing was opened in 1974 and was placed on the U.S. EPA Superfund (rehabilitation) list in 1982 because of odour complaints. Community concerns have focused on combustible gases, odour control, and exposure to trace contaminants. A comprehensive data base and corrective action program was initiated to determine: (1) the extent of off-site volatile organic compounds (VOC) migration; (2) measures to control migration and emissions; and (3) impacts on VOC concentrations under residential areas. Full data reports and monthly interpretations have been provided to the citizenry. Results to date indicate that start-up and operation of the extraction system have significantly reduced off-site VOC concentrations.  相似文献   