首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The construction in Constantí (Catalonia, Spain) of a new hazardous waste incinerator (HWI), which is the first one in Spain, finished in 1999. In order to determine the temporal variation (1996–1998) in the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in the vicinity of the new HWI, 40 soil and 40 herbage samples were collected (1998) at the same sampling points in which samples had been taken two years before (1996). Each sample was analyzed for PCDDs and PCDFs by high resolution gas chromatography/high resolution mass spectrometry. In the 1996 survey, PCDD/F concentrations in soils ranged from 0.13 to 24.20 ng I-TEQ/kg (d.m.), with median and mean values of 0.67 and 1.68 ng I-TEQ/kg (d.m.), respectively. In the present study, PCDD/F concentrations ranged from 0.12 to 17.20 ng I-TEQ/kg (d.m.), with a median value of 0.75 ng I-TEQ/kg (d.m.) and a mean value of 1.59 ng I-TEQ/kg (d.m.). In turn, in the present study PCDD/F concentrations in vegetation ranged from 0.14 to 2.01 ng I-TEQ/kg (d.m.) (median and mean values: 0.23 and 0.31 ng I-TEQ/kg, respectively), while in the 1996 survey PCDD/F concentrations ranged from 0.24 to 1.22 ng I-TEQ/kg (d.m.) (median and mean values: 0.53 and 0.61 ng I-TEQ/kg, respectively). According to the present (1998) and the previous (1996) levels of PCDD/Fs found in soils and vegetation, the area under potential influence of the new facility shows a rather low contamination by these compounds. The current results should be useful to establish the environmental impact of the HWI.  相似文献   

2.
The levels of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) were determined in soil and vegetation samples taken from 24 sites in the vicinity of an old municipal solid waste incinerator (San Adrià del Besòs, Barcelona, Spain). Duplicate samples were collected within a radius of 3 km from the stack. PCDD/F concentrations in soils ranged from 1.22 to 34.28 ng I-TEQ/kg (d.m.) with median and mean values of 9.06 and 12.24 ng I-TEQ/kg, respectively. In turn, the levels of PCDD/Fs in vegetation samples ranged from 0.33 to 1.98 ng I-TEQ/kg (d.m.), with median and mean values of 0.58 and 0.70 ng I-TEQ/kg, respectively. Although the present PCDD/F concentrations in soil samples were higher than those recently found in soils taken near other incinerators from Catalonia, they are of the same order of magnitude than the levels of these pollutants found in incinerators from other countries. By contrast, the concentrations of PCDD/Fs in herbage samples were comparable to those found in recent surveys carried out in Catalonia.  相似文献   

3.
The aim of this study was to measure, 6 years after regular operations, the concentrations of a number of organic substances in blood and urine of 19 workers employed at a hazardous waste incinerator (HWI) in Spain, and to establish the temporal variation with respect to baseline data and previously performed surveys. This facility was the first, and so far the only HWI in that country. The levels of hexachlorobenzene (HCB), polychlorinated biphenyls (PCB 28, 52, 101, 138, 153 and 180) and polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were analyzed in six composite plasma samples, while concentrations of di-, tri, and pentachlorophenols, as well those of 1-hydroxypyrene were measured in the urine of these workers. The current mean PCDD/F concentration, 10.4 ng I-TEQ/kg lipid, was significantly lower than that found in the baseline survey, 26.7 ng I-TEQ/kg lipid and similar to that found in the previous (2004) study (7.7 ng I-TEQ/kg lipid). PCDD/F levels in plasma were similar or even lower than those recently reported for various non-exposed populations. For the remaining analyzed substances in plasma and urine, there was not any significant increase in comparison with the levels found in the baseline survey. On the other hand, no marked differences between the concentrations of organic substances in plasma or urine were found according to the respective workplace (plant, laboratory and administration). The results of the present survey indicate that after 6 years of regular operation, the workers at the HWI are not occupationally exposed to PCDD/Fs and other organic substances in their workplaces.  相似文献   

4.
Polychlorinated dibenzo-p-dioxin (PCDD) and polychlorinated dibenzofuran (PCDF) levels were determined in adipose tissue of 15 autopsied subjects who at the time of death had lived in the city of Tarragona (Catalonia, Spain) and surroundings during at least the last 10 years. PCDD/F concentrations ranged between 13.37 and 69.37 ng I-TEQ/kg fat, with mean and median values of 30.98 and 26.30 ng I-TEQ/kg fat, respectively. PCDD/F concentrations were higher (p < 0.01) in women (mean value: 44.95 ng I-TEQ/kg fat) than in men (mean value: 24.00 ng I-TEQ/kg fat). Although individuals living in industrial areas showed higher PCDD/F levels than those living Tarragona downtown the difference was not statistically significant. When Principal Component Analysis was applied to the concentrations of PCDD/Fs found in the 15 adipose tissue samples together with those found in 20 blood samples collected in a previous study, a single two-dimensional model was obtained, which would explain 62.9% of the variance in the data. The PCDD/F concentrations in adipose tissue found in the current study are of the same order of magnitude than those reported for most industrialized countries.  相似文献   

5.
Concentrations of 17 toxic 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) have been determined in pooled samples of breast milk from 15 mothers living in two residential areas (Tarragona downtown and an industrial area) in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (southern Catalonia, Spain). PCDD/Fs in human milk samples ranged between 5.9 and 17.1 pg I-TEQ/g fat (162-498 pg I-TEQ/l), with a mean value of 11.8 pg I-TEQ/g fat (310.8 pg I-TEQ/l). The percentages of fat ranged between 1.53 and 3.52. Although PCDD/F levels in milk from mothers living in the industrial area were found to be slightly higher than those observed in women living Tarragona downtown, most differences did not reach the level of statistical significance. In general terms, PCDD/F concentrations in human milk (pooled) samples of mothers living in the area of Tarragona are similar or lower than those previously reported for most industrialized countries.  相似文献   

6.
Anderson DR  Fisher R 《Chemosphere》2002,46(3):371-381
Several countries have compiled national inventories of dioxin (polychlorinated dibenzo-p-dioxin [PCDD] and polychlorinated dibenzofuran [PCDF]) releases that detail annual mass emission estimates for regulated sources. High temperature processes, such as commercial waste incineration and iron ore sintering used in the production of iron and steel, have been identified as point sources of dioxins. Other important releases of dioxins are from various diffuse sources such as bonfire burning and domestic heating. The PCDD/F inventory for emissions to air in the UK has decreased significantly from 1995 to 1998 because of reduced emissions from waste incinerators which now generally operate at waste gas stack emissions of 1 ng I-TEQ/Nm3 or below. The iron ore sintering process is the only noteworthy source of PCDD/Fs at integrated iron and steelworks operated by Corus (formerly British Steel plc) in the UK. The mean waste gas stack PCDD/F concentration for this process is 1,2 ng I-TEQ/Nm3 based on 94 measurements and it has been estimated that this results in an annual mass release of approximately 38 g I-TEQ per annum. Diffuse sources now form a major contribution to the UK inventory as PCDD/Fs from regulated sources have decreased, for example, the annual celebration of Bonfire Night on 5th November in the UK causes an estimated release of 30 g I-TEQ, similar to that emitted by five sinter plants in the UK.  相似文献   

7.
This study investigates the emissions of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) from four electric arc furnaces (EAFs) and eight secondary aluminum smelters (secondary ALSs) in Taiwan. The mean PCDD/F International-Toxicity Equivalents (I-TEQ) concentrations in the stack gases of these EAFs and secondary ALSs are 0.28 ng I-TEQ/Nm3 (relative standard deviation [RSD]= 100%) and 3.3 ng I-TEQ/Nm3 (RSD = 260%), respectively. The high RSDs, especially for those obtained from secondary ALSs, could be caused by the intrinsic differences in their involved feeding materials, furnace operating conditions, and air pollution control devices. The mean I-TEQ emission factor of PCDD/Fs for EAFs (1.8 microg I-TEQ/tonne-feedstock) is lower than that for secondary ALSs (37 microg I-TEQ/tonne-feedstock). This result might be because the involved furnace temperatures for secondary ALSs (650-750 degrees C) are lower than those for EAFs (1600-1700 degrees C), resulting in the deterioration of the combustion condition, leading to the formation of PCDD/Fs during the industrial process. This study found that the total PCDD/F emissions from EAFs (20 g I-TEQ/yr) and secondary ALSs (18 g I-TEQ/yr) are approximately 27, 53, and approximately 24, 49 times higher than those from municipal solid waste incinerators (MSWIs; 0.74 g I-TEQ/yr) and medical waste incinerators (MWIs; 0.37 g I-TEQ/yr), respectively; while those are 44 and 40% of total PCDD/F emission from sinter plants (45 g I-TEQ/ yr), respectively. Considering a more stringent emission limit has been applied to waste incinerators (0.1 ng I-TEQ/Nm3) in Taiwan lately, the results suggest that the control of the emissions from metallurgical processes has become the most important issue for reducing the total PCDD/F emission from industrial sectors to the ambient environment.  相似文献   

8.
In this study, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDFs) in breast milk from mothers living in the vicinity of a new hazardous waste incinerator (HWI) were determined. Monitoring was performed after three years of regular operations in the facility and the present results were compared with baseline concentrations obtained in a pre-operational program. PCDD/PCDF levels were determined by HRGC/HRMS in 15 samples. In the present study, PCDD/PCDF concentrations ranged from 4.9 to 39.9 pg I-TEQ/g fat (5.1-46.8 pg WHO-TEQ/g fat), with a median value of 7.7 pg I-TEQ/g fat (9.1 pg WHO-TEQ/g fat). In the baseline survey, PCDD/PCDF concentrations ranged between 5.9 and 17.1 pg I-TEQ/g fat, with a median value of 11.7 pg I-TEQ/g fat. In relation to this, a percentage of reduction of 34.2% was noted. This decrease is in agreement with the relevant reduction found in the dietary intake of PCDD/PCDFs between both surveys. The results of the present study, as well as other recent environmental and biological data, indicate that living in the vicinity of this HWI should not mean additional health risks due to PCDD/PCDFs for the general population.  相似文献   

9.
The concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) were determined in plasma samples of 20 nonoccupationally exposed subjects living in the vicinity of a new hazardous waste incinerator (HWI), now under construction in Tarragona (Catalonia, Spain). The mean PCDD/F value was 27.0 pg I-TEQ/g lipid with a range from 14.8 to 48.9 pg I-TEQ/g lipid. All samples showed higher PCDD than PCDF levels. Although PCDD/F concentrations were higher in women (27.7 pg I-TEQ/g lipid) than in men (25.2 pg I-TEQ/g lipid), the difference was not statistically significant. While a significant correlation (r = 0.565, p < 0.01) between the age of the subjects and the levels of PCDD/F in plasma could be observed, no significant differences were found in relation to the specific residential area. The plasma concentrations of PCDD/F obtained in the current study are discussed and compared with the results of similar investigations reported in the last two years.  相似文献   

10.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

11.
Measurements of the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were made in ambient air, ash, and soil impacted by the open burning of wax apple and rice straw residues. Measurements showed that the mean PCDD/F concentration (0.458 pg I-TEQ/Nm3; international toxicity equivalence) in air at two wax apple orchards during open burning increased markedly, -8.1 times higher than that (0.057 pg I-TEQ/Nm3); before open burning. In addition, the mean PCDD/F concentration (0.409 pg I-TEQ/Nm3) in ambient air at a rice straw field was 4.6 times higher than that (0.089 pg I-TEQ/Nm3) before open burning. After burning the residues of wax apple stubble and rice straw, the contents of PCDD/F in ashes were 1.393 and 1.568 ng I-TEQ/kg-ash, respectively, and the contents of PCDD/F in soil were 2.258 and 2.890 ng I-TEQ/kg-soil, respectively. Therefore, the turnover of soil with the ash after open burning over years will result in the accumulation of PCDD/Fs in farm soils.  相似文献   

12.
Concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) and polychlorinated biphenyls (PCB) were determined in 23 soil samples collected at reference sites of the Swiss national soil monitoring network (NABO). Total PCDD/F and PCB concentrations are well correlated and proportional (R2=0.720). The total PCDD/F levels were between 72 and 703 ng/kg corresponding to 1.1-11 ng I-TEQ/kg, total PCB concentrations (sum of seven congeners IUPAC no. 28, 52, 101, 118, 138, 153, and 180) were from 1.1 to 12 microg/kg. In all samples, the PCDD/F and PCB concentrations were in the range of background levels for these contaminants in Central Europe. Ninteen samples revealed PCDD/F levels below the guide value of 5 ng I-TEQ/kg set by the Swiss ordinance relating to impacts on the soil (OIS); concentrations for the remaining four samples were below the trigger value (20 ng I-TEQ/kg). All PCB concentrations were below the guide value of 100 microg/kg. The elevated PCDD/F and PCB levels in some of the samples originating from forested sites could be attributed to the scavenging effect of forest canopies for semivolatile organic compounds. This interpretation could be substantiated by the observed distortion of the congener and homolog patterns of PCDD/F and PCB which is characteristic for forested sites.  相似文献   

13.
PCDD/F analyses were made in soil and ambient air samples taken from Kocaeli, an industrialized area of Turkey. Results showed that the levels of PCDD/F pollution are comparable to the levels observed in the various urban areas in the world. PCDD/F concentrations in surface soils ranged between 0.4 and 4.27 pg I-TEQ kg(-1) with a geometric mean of 0.76 pg I-TEQ kg(-1), while those in ambient air were between 23 and 563 f gm(-3), with geometric mean of 82.0 f gm(-3). Ambient air PCDD/F concentration in the city center was about 10 times higher than those in the rural area. Combustion activities present in the area were assessed to be the most significant source of the PCDD/F pollution based on the congener and homologue profiles and statistical analysis of the data. The deposition rate modeling of USEPA was applied and the deposition rates were determined in the range between 7.6 and 66.3 ng I-TEQ m(-2)year(-1) with a geometric mean of 15.9 ng I-TEQ m(-2)year(-1). The rates were higher than the recommended deposition rates in relation to the tolerable daily intake (TDI) range of PCDD/Fs for humans. The deposition velocities computed were also found to be high in both low and highly chlorinated PCDD/Fs, and this was attributed to the vapor phase deposition of volatile PCDD/Fs, and the scavenging effect of the precipitation on the particle-bound PCDD/Fs.  相似文献   

14.
Oh JE  Choi SD  Lee SJ  Chang YS 《Chemosphere》2006,64(4):579-587
To examine the influence of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) emissions from a municipal solid waste incinerator (MSWI) on the environment, we measured the levels of PCDD/Fs in ambient air and soil samples collected near a MSWI in Bucheon, Korea. The PCDD/Fs concentrations in the ambient air samples ranged from 0.22 to 1.16 pg I-TEQm(-3) (13.39-75.16 pg m(-3)), with an average of 0.66 pg I-TEQ m(-3) (35.62 pg m(-3)). The soil samples contained between 1.25 and 74.98 pg I-TEQ g(-1) (38.15-3,303.33 pg g(-1)), with an average of 19.06 pg I-TEQ g(-1) (1,077.11 pg g(-1)). These levels were higher than those previously reported by other investigators in a number of surveys. The furan homologues predominated in the air samples and some soil samples, and the soil PCDD/Fs levels decreased with increasing distance from the MSWI. Comparison of the homologue patterns and a multivariate statistical analysis showed that PCDD/Fs emission from the MSWI directly affected the pattern of PCDD/Fs in air, while the PCDD/Fs patterns in soil differed according to the location relative to the MSWI, roads, and construction sites. These results collectively indicate that the MSWI was the major PCDD/Fs emission source in this area, but that unidentified combustion sources and vehicles might influence the environment to some extent.  相似文献   

15.
Chang MB  Huang HC  Tsai SS  Chi KH  Chang-Chien GP 《Chemosphere》2006,62(11):1761-1773
Distribution of PCDD/F (polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran) congeners at two electric arc furnaces (EAFs) in Taiwan is evaluated via intensive stack sampling and analysis. Two kinds of exhaust system in EAFs including stack system and shutter system are selected for measuring dioxin emissions. In addition, dioxin emissions during oxidation and reduction stages at EAF-A were characterized. Results indicate that the PCDD/F concentration of stack gas in EAF-A was 4.39 ng/N m3 while total Toxic Equivalent Quantity (TEQ) concentration was 0.35 ng I-TEQ/N m3. The PCDD/F concentration of stack gas in EAF-B was 2.20 ng/N m3 and the TEQ concentration was 0.14 ng I-TEQ/N m3. 1,2,3,4,6,7,8-HpCDF, OCDD and OCDF are the major contributors of the dioxin concentrations for two EAFs investigated and the percentage of PCDD/F in particulate phase increases as the chlorination level of the PCDD/F congener increases. The results obtained on gas/particulate partitioning of PCDD/Fs in flue gases prior to the APCD in EAFs indicate that more than 90% exists in particulate phase. In EAF-A, the PCDD/F concentration during oxidation stage is slightly higher than that measured during reduction stage, including the sampling points of CO converter outlet, prior to bag filter and stack. Majority of PCDD/Fs emitted from steel-making processes exists in particulate-phase (about 60–70%) at both EAFs investigated.  相似文献   

16.
Yu BW  Jin GZ  Moon YH  Kim MK  Kyoung JD  Chang YS 《Chemosphere》2006,62(3):494-501
The metallurgy industry and municipal waste incinerators are considered the main sources of polychlorinated dibenzo-p-dioxin and dibenzofurans (PCDD/Fs) in many countries. This study investigated the emission factors and total emissions of PCDD/Fs and dioxin-like polychlorinated biphenyls (PCBs) emitted from metallurgy industries (including ferrous and nonferrous foundries) in Korea. The toxic equivalency (TEQ) emission factor of PCDD/Fs was the highest for secondary copper production, at 24451 ng I-TEQ/ton. The total estimated emissions of PCDD/Fs from these sources were 35.259 g I-TEQ/yr, comprising 0.088 g I-TEQ/yr from ferrous foundries, 31.713 g I-TEQ/yr from copper production, 1.716 g I-TEQ/yr from lead production, 0.111 g I-TEQ/yr from zinc production, and 1.631 g I-TEQ/yr from aluminum production. The total estimated annual amounts of dioxin-like PCBs emitted from these sources were 13.260 g WHO-TEQ/yr, comprising 0.014 g WHO-TEQ/yr from ferrous foundries, 12.675 g WHO-TEQ/yr from copper production, 0.170 g WHO-TEQ/yr from lead production, 0.017 g WHO-TEQ/yr from zinc production, and 0.384 g WHO-TEQ/yr from aluminum production. The highest emission factor was found for secondary copper smelting, at 9770 ng WHO-TEQ/ton.  相似文献   

17.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

18.
测定了流化床垃圾焚烧炉焚烧产生的飞灰、烟尘和烟气中的2,3,7,8位氯取代二噁英同类物的含量及其毒性当量。结果表明,产生的二噁英主要存在于飞灰中,烟气中的含量很少。飞灰中二噁英总浓度和毒性当量分别为8.44ng/g和0.80ng/g,经过布袋除尘器后的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为0.34ng/m^3和0.02ng/m^3,而布袋除尘器前的烟尘和烟气中二噁英的浓度之和与毒性当量之和分别为40.78ng/m^3和3.0ng/m^3。飞灰和烟尘中2,3,7,8位氯取代二噁英同类物的分布相似,但是与烟气中2,3,7,8位氯取代二噁英同类物的分布差别较大。通过了解有毒二噁英同类物的分布,可以进一步优化流化床垃圾焚烧炉的焚烧条件,降低二噁英的排放量,减少垃圾焚烧对环境的污染。  相似文献   

19.
To assess the influence of a new hazardous waste incinerator (HWI) on public health, a preoperational monitoring program was established during the period of construction. In this study, the levels of polychlorinated dibenzo-p-dioxins (PCDD) and dibenzofurans (PCDF) accumulated in adipose tissue of 15 autopsied subjects living in the area under potential impact of the HWI were determined after approximately 3 years of regular operations in the facility. The non-ortho PCBs 77, 126 and 169 were also determined. PCDD/F concentrations ranged between 1.5 and 41 pg WHO-TEQ/g fat (2.4 and 72 WHO-TEQ/g fat, respectively, including PCBs), with a mean value of 11 pg WHO-TEQ/g fat and a median value of 7.4 pg WHO-TEQ/g fat (22 and 13 WHO-TEQ/g fat, respectively, including PCBs). In the baseline study, the mean level of PCDD/Fs was 36 pg WHO-TEQ/g fat (61 pg WHO-TEQ/g fat, including non-ortho PCBs 77, 126 and 169), which means a reduction of 70% (64% including PCBs). This notable reduction is in accordance with the important decrease observed in recent years in PCDD/F intake through the diet. The current concentrations of PCDD/Fs in human adipose tissue, as well as recent data on PCDD/F levels in plasma and breast milk of subjects living in the vicinity of the same HWI, indicate that there is not any additional significant exposure to PCDD/Fs for this population.  相似文献   

20.
The US Food and Drug Administration has simultaneously utilized both high-resolution mass spectrometry (HRMS) and quadrupole ion storage tandem mass spectrometry (QISTMS) in the measurement of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) in 147 food samples collected in 1998 and 1999 in the US. In 1998, 20 egg samples, six scallop, 10 blue crab, eight American lobster, 10 pollack, 15 striped bass, five rockfish, 10 crawfish, seven aqua-cultured and 13 wild-caught salmon, along with 19 cream and 18 mozzarella cheese samples were measured for PCDD/Fs. QISTMS provided limits of detection (LODs) close to those produced using HRMS for many congeners in 56 samples analyzed by both techniques in 1998 and three salmon and three striped bass collected in 1999. The I-TEQs of the mean levels for measured congeners in 40 samples of fish and shellfish and 16 cheese and eggs from 1998 analyzed by HRMS and QISTMS were 0.99 and 1.1 ng/kg wet weight, respectively. The I-TEQ for mean congener levels in the 40 fish and shellfish measured by HRMS was 1.4 ng/kg wet weight. A higher sample throughput with greater data quality at a lower cost is achievable by using both QISTMS and HRMS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号