首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were monitored in stack gas and fly ash of various Korean incinerators and in air samples collected near the facilities. Concentrations of PCDD/Fs in emissions were investigated, and characteristic PCDD/F homologue patterns were classified using statistical analyses. The PCDD/F emission levels in stack gas and fly ash samples from small incinerators (SIs) were higher than those from municipal solid waste incinerators (MSWIs). The PCDD/F concentrations ranged between 0.38 and 1.16 pg I-TEQ/m3 (21.2-75.2 pg/m3) in ambient air samples. The lower-chlorinated furans were the dominant components in most of the stack gas and fly ash samples from SIs, although this was not the case for fly ash from MSWIs. This homologue pattern is consistent with other studies reporting a high fraction of lower-chlorinated furans in most environmental samples affected by incinerator emissions, and it can be used as an indicator to assess the impact of such facilities on the surrounding environment.  相似文献   

2.
Congener profiles are the fractional distribution of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) congeners in an environmental release, or in an environmental or biological sample. In 1999, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an old municipal solid waste incinerator (MSWI) from Montcada (Barcelona, Spain). The main goal of the present study was to determine if the environmental PCDD/F levels in the area under direct influence of the facility were mainly due to PCDD/F emissions from the plant. For this purpose, soil and herbage samples were collected near the MSWI before (1998) and after (2000) the technical improvements were performed. PCDD/F congener profiles were determined and compared with those from samples collected in a suburban area of Constantí (Tarragona, Spain) outside of direct emissions from any MSWI. The results of the present study suggest that the MSWI here assessed is not the main responsible for the environmental PCDD/F concentrations in the area under evaluation. Other PCDD/F emission sources in the same area seem also to have a notable impact on the atmospheric levels of these pollutants.  相似文献   

3.
Hart JR 《Chemosphere》2008,72(1):75-78
Emissions and inlet concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/PCDF) have been measured from a catalytic oxidizer and a thermal oxidizer. The catalyst inlet temperature was 427 degrees C. The thermal oxidizer operating temperature was 791 degrees C. Data of the toxic dioxin and furan congeners are reported. Important results of this field study are: (1) the catalytic oxidizer in this study produced an increase in PCDD/PCDF congener concentration of almost 10-fold from the inlet to the outlet (stack), thus verifying results of a previous study that evaluated only PCDD/PCDF emissions. All congeners increased from inlet to the stack. (2) The thermal oxidizer had little effect on PCDD/PCDF levels. There was a decrease in four of the congeners and an increase in 13 congeners. (3) Ambient air was the main source of PCDD/PCDFs in the stack emissions of the thermal oxidizer in this study. Laboratory investigations are needed to understand how PCDD/PCDFs are formed (and emitted) under conditions of this study.  相似文献   

4.
Analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) has been performed using gas chromatography mass spectrometry (GC-MS). Analysis of the most toxic isomers, in particular, 2,3,7,8-substituted PCDD/PCDF in the presence of other isomers requires a special isomer specific capillary column or high performance liquid chromatography (HPLC) fractionation prior to GC-MS analysis. Commercially available long (>50 m) polar columns can separate 2,3,7,8-TCDD from other tetra isomers. However, those columns are not satisfactory for the analyses of total PCDD/PCDF in the environmental samples. Gas chromatography -high resolution mass spectrometry (GC-HRMS) and GC-MS/MS techniques are not helpful in the analysis of 2,3,7,8-TCDD unless it is separated from the other tetra isomers. The analysis of 2,3,7,8-TCDD and total PCDD and PCDF in a single GC-MS run can ease the laborious techniques presently used. In this study we have developed a new stationary phase for the GC capillary column. The capillary column developed using this new stationary phase showed unsurpassed selectivity for the separation of 2,3,7,8-TCDD from other tetra isomers. There are several advantages of the newly developed GC capillary column.  相似文献   

5.
A survey to estimate the polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) emissions of Spanish hot dip galvanising sector was carried out during 2002. This investigation is the first presenting Spanish experimental data related to this industrial sector. Three different matrices: flue gas, ash and filter dust were tested to quantify the PCDD/Fs generated during the galvanising process. The organic source of PCDD/F formation could be from the insufficient degreasing o from inhibitors or additives used in the pickling steps such as quinoline, isoquinoline, 8-methylquinoline or polyether phosphoric acid. Low levels PCDD/Fs were achieved in air emissions when air control devices are used. On the contrary, filter dusts are highly contaminated; indicating that the absence of air control devices would increase the risk of fugitive emissions. Homologue profiles and Principal Component Analysis demonstrate there are differences in the formation mechanisms in the bath zone (ashes) compared to the stack location (filter dusts and air emissions), related to the de novo synthesis and reaction time. The annual PCDD/F emission to the atmosphere for this sector during 2002 has been estimated in 0.023g I-TEQ. The emission factor of plants with air control devices has been calculated at 0.030microg I-TEQ/ton of galvanised steel.  相似文献   

6.
7.
In 2005 and 2006, the levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polychlorinated biphenyls (PCBs) and metals (As, Be, Cd, Co, Cr, Cu, Mn, Ni, Pb, Sn, Tl and V) were measured in air samples collected in an industrial area of Sant Adrià del Besòs (Barcelona, Catalonia, Spain) where a municipal solid waste incinerator (MSWI) is placed, and in a background/control area. In general terms, concentrations of all environmental pollutants were higher at the industrial site. No significant seasonal/temporal variations were observed in any of the areas. No Pearson correlation was found between the PCDD/F concentrations and the environmental conditions of the two sampling periods considered. Principal component analyses (PCA) were performed to get information on the relationship among samples, pollutants, and emission sources. The results indicate that the MSWI of S. Adrià de Besòs is not a significant emission source of the above compounds for the area under its direct influence. Moreover, a notable difference in the PCDD/F congener profiles was found between ambient air and stack gas emissions, indicating that the current levels of PCDD/Fs are more related to other potential emissions sources rather than to those from the MSWI.  相似文献   

8.
The stack gases of a municipal solid waste incinerator (MSWI), and ambient air were sampled in four locations around the plant for the analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs). The sampling area was close to an industrial area near Trieste, in north-east Italy. The purpose of the study was to estimate the impact of the MSWI emissions and to distinguish the contribution of these emissions from other potential emission sources in the industrial area.PCDD/F atmospheric concentrations were similar to those generally detected in urban–rural areas with one location about 2–3 times more contaminated than the others. Since the most contaminated location was inside the industrial area but upwind of the MSWI, principal component analysis (PCA) was used to establish whether other sources were the cause. This analysis clearly showed that a local steel plant’s emission was the main source of PCDDs/Fs in ambient air. This study highlights the usefulness of multivariate data analysis such as PCA to identify, among different potential emission sources, the one really responsible for the contamination.  相似文献   

9.
Nine typical waste incinerating plants were investigated for polychlorinated naphthalene (PCN) contents in their stack gas. The incinerators investigated include those used to incinerate municipal solid, aviation, medical, and hazardous wastes including those encountered in cement kilns. PCNs were qualified and quantified by isotope dilution high resolution gas chromatography–high resolution mass spectrometry techniques. An unexpectedly high concentration of PCNs (13,000 ng?Nm?3) was found in the stack gas emitted from one waste incinerator. The PCN concentrations ranged from 97.6 to 874 ng?Nm?3 in the other waste incinerators. The PCN profiles were dominated by lower chlorinated homologues, with mono- to tetra-CNs being the main homologues present. Furthermore, the relationships between PCNs and other unintentional persistent organic pollutants involving polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated biphenyls, hexachlorobenzene, and pentachlorobenzene were examined to ascertain the closeness or otherwise of their formation mechanisms. A good correlation was observed between ΣPCN (tetra- to octa-CN) and ΣPCDF (tetra- to octa-CDF) concentrations suggesting that a close relationship may exist between their formation mechanisms. The results would provide an improved understanding of PCN emissions from waste incinerators.  相似文献   

10.
Emission of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) by municipal solid waste incinerators (MSWI) is an issue of great concern. In 1997, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in an MSWI from Tarragona (Catalonia, Spain). As a result, PCDD/F emissions were significantly reduced. The aim of this study was to determine the current levels of PCDD/Fs in soil and vegetation samples collected near the facility and to compare these levels with those obtained in previous surveys (1996 and 1997). In the period 1997-1999, PCDD/F concentrations in vegetation samples were significantly decreased (60%). By contrast, the levels of PCDD/Fs in soil samples increased slightly (14%, P > 0.05) during the same period. An exhaustive analysis of the present data indicates that other emission sources of PCDD/Fs have also a notable environmental impact on the area under direct influence of the MSWI.  相似文献   

11.
PCDTs in the environment   总被引:3,自引:0,他引:3  
Seija Sinkkonen 《Chemosphere》1997,34(12):2585-2594
Polychlorinated dibenzothiophenes (PCDTs) are sulfur analogues of polychlorinated dibenzofurans. Recently, PCDTs have been found in stack gas and fly ash samples, pulp mill effluents, sediments and in some aquatic organisms. PCDTs have been analyzed by high resolution GC/MS and by other GC-MS techniques. Combustion is until now the major known source of PCDTs in the environment. Tri-, tetra- and pentaCDTs in concentrations approaching those of PCDTs have been analyzed in some samples from waste incineration and metal reclamation. Concentrations of PCDTs in pulp mill effluents have been found to be quite low. 2378-TeCDT was found to be the major TeCDT isomer in some pulp mill effluents. Preliminary toxicological investigations have shown that PCDTs possess some kind of dioxin type toxicity.  相似文献   

12.
Although PCB in caulking materials has been forbidden for many years in most of Europe, including Denmark, there has been continued interest to measure PCB levels in the air of contaminated buildings and blood of the occupants (Mengon and Schlatter 1993, Fromme et al. 1996, Ewers et al. 1998, Currado and Harrad 1998, Gabrio et al. 2000). The relatively low priority for investigations of this contamination is probably due to the small quantities inhaled compared to exposure via food, and the rapid metabolism of the most volatile congeners demonstrated by low concentrations of all congeners in the blood of exposed persons (Ewers et al. 1998, Gabrio et al. 2000). There is, however, evidence that PCB containing caulking materials have been used even during the '90s (Fromme et al. 1996). In Denmark, it is estimated that 75 t PCB is still in buildings (Organization of Sealant Branch's Manufacturers and Distributors 2000). During an investigation of dust from buildings with excessive microbial growth (including 35 rooms from 9 buildings), the analysis of semivolatile compounds by thermal desorption-GC/MS of samples from a single building surprisingly revealed large amounts of PCBs containing 3, 4 and 5 chlorine atoms, 10-20 times the amounts found in samples from other buildings. Extraction of the dust by SFE followed by GC/ECD analysis for 12 PCB congeners showed that there was approximately 20 times the total PCB concentrations in dust from the polluted building compared to the levels in the other buildings. Subsequent headspace analysis of caulking material from the polluted building revealed this to be the source. Shelf dust functions as a passive sampling medium and, thus, can be used as a screening method to detect PCB and other semivolatile pollution indoors.  相似文献   

13.
Emissions of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDDs/Fs) from incinerators and other stationary combustion sources are of environmental concern because of the toxicity of certain PCDD/F congeners. Measurement of trace levels of PCDDs/Fs in combustor emissions is not a trivial matter. Development of one or more simple, easy-to-measure, reliable indicators of stack PCDD/F concentrations not only would enable incinerator operators to economically optimize system performance with respect to PCDD/F emissions, but could also provide a potential technique for demonstrating compliance status on a more frequent basis. This paper focuses on one approach to empirically estimate PCDD/F emissions using easy-to-measure volatile organic C2 chlorinated alkene precursors coupled with flue gas cleaning parameters. Three data sets from pilot-scale incineration experiments were examined for correlations between C2 chlorinated alkenes and PCDDs/Fs. Each data set contained one or more C2 chloroalkenes that were able to account for a statistically significant fraction of the variance in PCDD/F emissions. Variations in the vinyl chloride concentrations were able to account for the variations in the PCDD/F concentrations strongly in two of the three data sets and weakly in one of the data sets.  相似文献   

14.
This study aims to evaluate the influence of start-up on polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans (PCDD/Fs) concentration in the stack flue gas of incinerators and its contributing PCDD/F emission. The PCDD/F emission of the first sample among three consecutive stack flue gas samples of five intermittent incinerators, which sampled at a stable combustion condition after start-up, is 2-3 times higher than the mean of the others. For verifying the PCDD/F characteristics of incinerators during start-up, one continuous MSWI was investigated for two years. The elevated PCDD/F emissions of the MSWI during start-up could reach 96.9 ng I-TEQN m(-3) and still maintained a high PCDD/F emission (40 times higher than the Taiwan emission limit) even 18 h after the injection of activated carbon, indicating the memory effect. Taking the MSWI for example, which consists of four incinerators, the estimated annual PCDD/F emission from normal operational conditions was 0.112 g I-TEQ. However, one start-up procedure can generate approximately 60% of the PCDD/F emissions for one whole year of normal operations. And the PCDD/F emission, which is the result of the start-ups of four incinerators, was at least two times larger than that of a whole year's normal operations, without consideration for the PCDD/F emission contributed by the long lasting memory effect.  相似文献   

15.
Cheng PS  Hsu MS  Ma E  Chou U  Ling YC 《Chemosphere》2003,52(9):1389-1396
Levels of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in twenty-one ambient air samples, eight soil samples and two stack gas samples, collected near or in a municipal solid waste incinerator (MSWI) in Hsinchu, Taiwan. A systematic decrease of PCDD/Fs in the ambient air from the northeastern area was observed. PCDD/Fs levels measured in the ambient air range from 0.058 to 0.127 pg-TEQ/m3. Higher PCDD/Fs levels in the ambient air were found during winter. In addition, PCDD/Fs levels measured in the soil range from 0.524 to 5.02 pg-TEQ/g d.m. Principal component analysis (PCA) and hierarchical cluster analysis (HCA) did not provide sufficient evidence that the environmental PCDD/Fs contamination was caused by emissions from the Hsinchu MSWI. An unknown PCDD/Fs source was proposed using congener profile analysis and supported by both PCA and HCA.  相似文献   

16.
A global, three-dimensional tropospheric chemistry model was used to perform simulations of the tropospheric distribution of carbon monoxide (CO) coinciding with NASA's Measurement of Air Pollution from Satellites (MAPS) experiment which took place during 5–13 October 1984. Archived meteorological data for September and October, 1984, were obtained from the European Centre for Medium-Range Weather Forecasting and used to drive the offline chemical transport model simulations. Base-case CO emissions were generated by applying emission factors to compiled inventories for related or co-emitted trace species. Simulation results from September and October have been compared with a recent re-release of the 1984 MAPS data and with in situ correlative data taken during the MAPS mission. Because of unrealistically large spatial variability in N2O mixing ratios measured concurrently by MAPS, model results were also compared with an adjusted CO data set generated by assuming that errors in N2O measured mixing ratios were correlated with errors in the MAPS CO data. These comparisons, in conjunction with simulations probing model sensitivities, led to the conclusion that biomass burning CO emissions from central and southern Africa may have been larger during September and October, 1984, than our initial best estimate based on the CO2 emissions data of Hao et al. (1990. Fire in the Tropical Biota; Ecosystem Processes and Global Challenges. Springer, Berlin, pp. 440–462; 1994. Global Biogeochemical Cycles 8, 495–503). This result is in disagreement with recent estimates of biomass burning emissions from Africa (Scholes et al., 1996, Journal of Geophysical Research 101, 23677–23682) which are smaller than previously thought for emissions from this region. Although unknown model deficiencies cannot be conclusively ruled out, model sensitivity studies indicate that increased CO emissions from central and southern Africa offer the best explanation for reducing observed differences between model results and MAPS data for this time period. Our results, in combination with a disparity in recent CO emission estimates from this region (Scholes et al., 1996; Hao et al., 1996, Journal of Geophysical Research 101, 23577–23584), and in light of recent indications of highly variable biomass burning activities from the tropical western Pacific (Folkins et al., 1997, Journal of Geophysical Research 102, 13291–13299), seem to suggest that biomass burning emissions exhibit significant year-to-year variability. This large variability of emissions sources makes the accurate simulation of specific time periods very difficult and suggests that biomass burning trace species inventories may have to be developed specifically for each simulated time period, employing satellite-derived information on fire coverage and flame intensity.  相似文献   

17.
Recently, we measured the concentrations of polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in soil and herbage samples collected in the vicinity of a municipal solid waste incinerator (MSWI) from Tarragona (Catalonia, Spain). Since these concentrations could be increased by the presence of other emission sources of PCDD/Fs in the same area in which the MSWI is placed, the main goal of the present study was to determine the PCDD/F congener profiles in the soil and vegetation samples collected in 1996 and again in 1997 near to the facility and to compare with those from samples collected in a close area outside of direct emissions of the plant. From an accurate inspection of the PCDD/F congener profiles, it was concluded that PCDD/F emissions from the MSWI here examined are neither the only nor the main responsible for the presence of PCDD/Fs in the samples of environmental matrices collected in the area under direct influence of the plant.  相似文献   

18.
Food intake is the main source of exposure to dioxin-like compounds for humans. The results of a surveillance programme on polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and co-planar polychlorinated biphenyls (co-PCBs) in 77 food samples from the Greek market and producers are presented. The study included the analyses of milk and dairy products, meat and meat products, fish, vegetable oil, eggs, fruit, vegetable and rice collected between August and December 2002. After extraction, extracts were cleaned up on a series of carbon column chromatography, silica gel, alumina chromatography, and then analysed by high resolution gas chromatography/high resolution mass spectrometry. All samples had a dioxin content far below the EC Regulation (2375/2001/EC) limits.  相似文献   

19.
Described are the results from studies done to provide test methods for state and local air pollution control agencies to measure accurately the lead emissions from stationary source stacks as required in the National Ambient Air Quality Standard for Lead. Separate test methods were developed for measuring inorganic lead and alkyl lead compounds. Inorganic lead is collected in a standard particulate sampling train, digested with 50% (V/V) nitric acid and 3% hydrogen peroxide and analyzed by atomic absorption spectrometry. Alkyl lead compounds are collected in iodine monochloride and analyzed by atomic absorption spectrometry without prior solvent extraction. Standard solutions of inorganic lead in dilute nitric acid are used to calibrate the spectrophotometer in both methods. The inorganic lead test method was evaluated using baghouse dust samples from a primary copper and a primary lead smelter and stack samples from a lead recovery furnace, a primary battery manufacturing plant, a gray iron foundry and a secondary lead smelter. The alkyl lead method was evaluated using alkyl lead motor mix fluids and samples from an alkyl lead manufacturing plant vent stack.  相似文献   

20.
Chemical emissions from research and development (R&D) activities are difficult to estimate because of the large number of chemicals used and the potential for continual changes in processes. In this case study, stack measurements taken from R&D facilities at Pacific Northwest National Laboratory (PNNL) were examined, including extreme worst-case emissions estimates and alternate analyses using a Monte Carlo method that takes into account the full distribution of sampling results. The objective of this study was to develop techniques to estimate emissions from stack measurement data that take into account a high degree of variability in the actual emissions. The results from these analyses were then compared to emissions estimated from chemical inventories. Results showed that downwind ambient air concentrations calculated from the stack measurement data were below acceptable source impact levels (ASILs) for almost all compounds, even under extreme worst-case analyses. However, for compounds with averaging periods of a year, the unrealistic but simplifying extreme worst-case analysis often resulted in calculated emissions that were above the lower level regulatory criteria used to determine modeling requirements or to define trivial releases. Compounds with 24-hr averaging periods were nearly all several orders of magnitude below all, including the trivial release, criteria. The alternate analysis supplied a more realistic basis of comparison and an ability to explore effects under different operational modes.

Implications:

Air emissions from research operations are difficult to estimate because of the changing nature of research processes and the small quantity and wide variety of chemicals used. Stack measurements can be used to verify compliance with applicable regulatory criteria. This study shows that while extreme worst-case assumptions can be used for a relatively simple initial comparison, methods that take into account the full range of measurement data are needed to provide a more realistic estimate of emissions for comparison to regulatory criteria, particularly those criteria that define trivial levels of environmental concern.  相似文献   


设为首页 | 免责声明 | 关于勤云 | 加入收藏