首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到4条相似文献,搜索用时 0 毫秒
1.
During the first European Tracer Experiment (ETEX) tracer gas was released from a site in Brittany, France, and subsequently observed over a range of 2000 km. Hourly measurements were taken at the National Environmental Research Institute (NERI) located at Risø, Denmark, using two measurement techniques. At this location, the observed concentration time series shows a double-peak structure occurring between two and three days after the release. By using the Danish Emergency Response Model of the Atmosphere (DERMA), which is developed at the Danish Meteorological Institute (DMI), simulations of the dispersion of the tracer gas have been performed. Using numerical weather-prediction data from the European Centre for Medium-Range Weather Forecast (ECMWF) by DERMA, the arrival time of the tracer is quite well predicted, so also is the duration of the passage of the plume, but the double-peak structure is not reproduced. However, using higher-resolution data from the DMI version of the HIgh Resolution Limited Area Model (DMI-HIRLAM), DERMA reproduces the observed structure very well. The double-peak structure is caused by the influence of a mesoscale anti-cyclonic eddy on the tracer gas plume about one day earlier.  相似文献   

2.
This paper presents results from a series of numerical experiments designed to evaluate operational long-range dispersion model simulations, and to investigate the effect of different temporal and spatial resolution of meteorological data from numerical weather prediction models on these simulations. Results of Lagrangian particle dispersion simulations of the first tracer release of the European Tracer Experiment (ETEX) are presented and compared with measured tracer concentrations. The use of analyzed data of higher resolution from the European Center for Medium-Range Weather Forecasts (ECMWF) model produced significantly better agreement between the concentrations predicted with the dispersion model and the ETEX measurements than the use of lower resolution Navy Operational Global Atmospheric Prediction System (NOGAPS) forecast data. Numerical experiments were performed in which the ECMWF model data with lower vertical resolution (4 instead of 7 levels below 500 mb), lower temporal resolution (12 h instead of 6 h intervals), and lower horizontal resolution (2.5° instead of 0.5°) were used. Degrading the horizontal or temporal resolution of the ECMWF data resulted in decreased accuracy of the dispersion simulations. These results indicate that flow features resolved by the numerical weather prediction model data at approximately 45 km horizontal grid spacing and 6 h time intervals, but not resolved at 225 km spacing and 12 h intervals, made an important contribution to the long-range dispersion.  相似文献   

3.
A comprehensive validation of FLEXPART, a recently developed Lagrangian particle dispersion model based on meteorological data from the European Centre for Medium-Range Weather Forecasts, is described in this paper. Measurement data from three large-scale tracer experiments, the Cross-Appalachian Tracer Experiment (CAPTEX), the Across North America Tracer Experiment (ANATEX) and the European Tracer Experiment (ETEX) are used for this purpose. The evaluation is based entirely on comparisons of model results and measurements paired in space and time. It is found that some of the statistical parameters often used for model validation are extremely sensitive to small measurement errors and should not be used in future studies. 40 cases of tracer dispersion are studied, allowing a validation of the model performance under a variety of different meteorological conditions. The model usually performs very well under undisturbed meteorological conditions, but it is less skilful in the presence of fronts. The two ETEX cases reveal the full range of the model’s skill, with the first one being among the best cases studied, and the second one being, by far, the worst. The model performance in terms of the statistical parameters used stays rather constant with time over the periods (up to 117 h) studied here. It is shown that the method used to estimate the concentrations at the receptor locations has a significant effect on the evaluation results. The vertical wind component sometimes has a large influence on the model results, but on the average only a slight improvement over simulations which neglect the vertical wind can be demonstrated. Subgrid variability of mixing heights is important and must be accounted for.  相似文献   

4.
A tracer model, the DREAM, which is based on a combination of a near-range Lagrangian model and a long-range Eulerian model, has been developed. The meteorological meso-scale model, MM5V1, is implemented as a meteorological driver for the tracer model. The model system is used for studying transport and dispersion of air pollutants caused by a single but strong source as, e.g. an accidental release from a nuclear power plant. The model system including the coupling of the Lagrangian model with the Eulerian model are described. Various simple and comprehensive parameterizations of the mixing height, the vertical dispersion, and different meterological input data have been implemented in the combined tracer model, and the model results have been validated against measurements from the ETEX-1 release. Several different statistical parameters have been used to estimate the differences between the parameterizations and meterological input data in order to find the best performing solution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号