首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 296 毫秒
1.
This paper investigates the prediction of solar radiation model and actual solar energy in Osmaniye, Turkey. Four models were used to estimate using the parameters of sunshine duration and average temperature. In order to obtain the statistical performance analysis of models, the coefficient of determination (R2), mean absolute percentage error (MAPE), mean absolute bias error (MABE), and root mean square error (RMSE) were used. Results obtained from the linear regression using the parameters of sunshine duration and average temperature showed a good prediction of the monthly average daily global solar radiation on a horizontal surface. In order to obtain solar energy, daily and monthly average solar radiation values were calculated from the five minute average recorded values by using meteorological measuring device. As a result of this measurement, the highest monthly and yearly mean solar radiation values were 698 (April in 2013) and 549 (2014 year) W/m2 respectively. On an annual scale the maximum global solar radiation changes from 26.38 MJ/m2/day by June to 19.19 MJ/m2/day by September in 2013. Minimum global solar radiation changes from 14.05 MJ/m2/day by October to 7.20 MJ/m2/day by January in 2013. Yearly average energy potential during the measurement period was 16.53 MJ/m2/day (in 2013). The results show that Osmaniye has a considerable solar energy potential to produce electricity.  相似文献   

2.
This study assessed the performance of six solar radiation models. The objective was to determine the most accurate model for estimating global solar radiation on a horizontal surface in Nigeria. Twenty-two years meteorological data sets collected from the Nigerian Meteorological agency and the National Aeronautics and Space Administration for the three regions, covering the entire climatic zones in Nigeria were utilized for calibrating and validating the selected models for Nigeria. The accuracy and applicability of various models were determined for three locations (Abuja, Benin City, and Sokoto), which spread across Nigeria using seven viable statistical indices. This study found that the estimation results of considered models are statistically significant at the 95% confidence level, but their accuracy varies from one location to another. However, the multivariable regression relationship deduced in terms of sunshine ratio, air temperature ratio, maximum air temperature, and cloudiness performs better than other relationships. The multivariable relationship has the least root mean square error and mean absolute bias error, not exceeding 1.0854 and 0.8160 MJ m?2 day?1, respectively, and monthly relative percentage error in the range of ± 12% for the study areas.  相似文献   

3.
The heat-pipe solar water heating (HP-SWH) system and the heat-pipe photovoltaic/thermal (HP-PV/T) system are two practical solar systems, both of which use heat pipes to transfer heat. By selecting appropriate working fluid of the heat-pipes, these systems can be used in the cold region without being frozen. However, performances of these two solar systems are different because the HP-PV/T system can simultaneously provide electricity and heat, whereas the HP-SWH system provides heat only. In order to understand these two systems, this work presents a mathematical model for each system to study their one-day and annual performances. One-day simulation results showed that the HP-SWH system obtained more thermal energy and total energy than the HP-PV/T system while the HP-PV/T system achieved higher exergy efficiency than the HP-SWH system. Annual simulation results indicated that the HP-SWH system can heat the water to the available temperature (45°C) solely by solar energy for more than 121 days per year in typical climate regions of China, Hong Kong, Lhasa, and Beijing, while the HP-PV/T system can only work for not more than 102 days. The HP-PV/T system, however, can provide an additional electricity output of 73.019 kWh/m2, 129.472 kWh/m2, and 90.309 kWh/m2 per unit collector area in the three regions, respectively.  相似文献   

4.
Considering successive and costly increases in electricity rates, this article evaluates the generation of electricity from a photovoltaic system using solar energy, a renewable source. The solar photovoltaic system is installed at UNIVATES University Center, a public university in the state of Rio Grande do Sul, Brazil, and it is also connected to the electrical grid. Data related to the climatic conditions of the location, such as incident solar radiation, rainfall, and mean temperature, were obtained during the system's evaluation period and used along with bibliographic research on similar systems installed in southern Brazil. Our study quantified the energy produced over one calendar year (2014) and related it to the climatic variables and the conversion efficiency achieved by the system's photovoltaic modules. Our results show that there is both a strong relationship between the production of energy and climatic conditions and that the city, Lajeado, and the Brazilian state of Rio Grande do Sul, have good potential to supply energy using photovoltaic systems connected to the electrical grid. The horizontal global solar radiation average obtained in the study location was 4.14 kilowatts per square meter per day (kWh/m2/day), and the average monthly production of energy reached 243.93 kWh/m2/month, with a total of 2,927.10 kWh produced in 2014, achieving a monthly average conversion efficiency of 11.07%. This conversion efficiency is close to the value of 12.6% obtained in 2013 in a similar study of the same solar photovoltaic system conducted over a shorter time period.  相似文献   

5.
This study investigated the thin-layer drying kinetics of salted silver jewfish in a hybrid solar drying system and under open sun. Ten drying models were compared with experimental data of salted silver jewfish drying. A new model was introduced, which is an offset linear logarithmic (offset modified Page model). The fit quality of the models was evaluated using the coefficient of determination (R2), root mean square error (RMSE), and sum of squared absolute error (SSAE). The result showed that Midilli et al. model and new model were comparable with two or three-term exponential drying models. This study also analyzed energy and exergy during solar drying of salted silver jewfish. Energy analysis throughout the solar drying process was estimated on the basis of the first law of thermodynamics, whereas exergy analysis during solar drying was determined on the basis of the second law of thermodynamics. At an average solar radiation of 540 W/m2 and a mass flow rate of 0.0778 kg/sec, the collector efficiency and drying system efficiency were about 41% and 23%, respectively. Specific energy consumption was 2.92 kWh/kg. Moreover, the exergy efficiency during solar drying process ranged from 17% to 44%, with an average value of 31%. The values of improvement potential varied between 106 and 436 W, with an average of 236 W.  相似文献   

6.
Paech, Simon J., John R. Mecikalski, David M. Sumner, Chandra S. Pathak, Quinlong Wu, Shafiqul Islam, and Taiye Sangoyomi, 2009. A Calibrated, High‐Resolution GOES Satellite Solar Insolation Product for a Climatology of Florida Evapotranspiration. Journal of the American Water Resources Association (JAWRA) 45(6):1328‐1342. Abstract: Estimates of incoming solar radiation (insolation) from Geostationary Operational Environmental Satellite observations have been produced for the state of Florida over a 10‐year period (1995‐2004). These insolation estimates were developed into well‐calibrated half‐hourly and daily integrated solar insolation fields over the state at 2 km resolution, in addition to a 2‐week running minimum surface albedo product. Model results of the daily integrated insolation were compared with ground‐based pyranometers, and as a result, the entire dataset was calibrated. This calibration was accomplished through a three‐step process: (1) comparison with ground‐based pyranometer measurements on clear (noncloudy) reference days, (2) correcting for a bias related to cloudiness, and (3) deriving a monthly bias correction factor. Precalibration results indicated good model performance, with a station‐averaged model error of 2.2 MJ m?2/day (13%). Calibration reduced errors to 1.7 MJ m?2/day (10%), and also removed temporal‐related, seasonal‐related, and satellite sensor‐related biases. The calibrated insolation dataset will subsequently be used by state of Florida Water Management Districts to produce statewide, 2‐km resolution maps of estimated daily reference and potential evapotranspiration for water management‐related activities.  相似文献   

7.
This experimental work has been conducted to compare the performance of the modified stills with that of the conventional still. Three modified stills (S1, S2, and S3) and conventional still (S4) were fabricated, each with 0.5 m2 of the basin area. S1 and S3 had transparent double glass walls with air in between acting as insulation, whereas S2 has a single transparent wall. S4 has insulated plywood walls painted black from inside. A mixture of coco peat and charcoal was used in S1, S2, and S3, whereas there was no basin material for S4. Experiments were conducted by changing the water quantity in the solar still ranging from 5 to 10 kg. Maximum distillate output of 5.46 l/m2-d was obtained for S2, whereas it was 3.80 l/m2-d for S4 for an average solar radiation intensity of 675 W/m2 (24.3 MJ/m2-d). Use of transparent walls with troughs to collect condensate increased the condenser area by 78.4%. The distillate water cost per liter was estimated as Rs. 0.86 (0.013 US$) and Rs. 1.61 (0.025 US$) for S2 and S4, respectively. Energy payback time for S2 was estimated as 4 months. Theoretical and experimental values showed that there is a significant loss of incoming solar radiation due to wall shadow.  相似文献   

8.
In this study, an experimental investigation on the performance of a small-scale residential-size solar-driven adsorption (silica gel-water) cooling system that was constructed at Assiut University campus, Egypt is carried out. As Assiut area is considered as hot, arid climate, field tests for performance assessment of the system operation during the summer season are performed under different environmental operating conditions. The system consists of an evacuated tube with a reflective concentration parabolic surface solar-collector field with a total area of 36 m2, a silica gel-water adsorption chiller of 8 kW nominal cooling capacity, and hot and cold water thermal storage tanks of 1.8 and 1.2 m3 in volume, respectively. The results of summer season field test show that under daily solar insolation varying from 21 to 27 MJ/m2, the solar collectors employed in the system had high and almost constant thermal efficiency. The daily solar-collector efficiency during the period of system operation ranged from about 50% to 78%. The adsorption chiller performance shows that the chiller average daily coefficient of performance (COP) was 0.41 with the average cooling capacity of 4.4 kW when the cooling-water and chilled-water temperatures were about 31°C and 19°C, respectively. As the chiller cooling water is cooled by the cooling tower in the hot arid area, the cooling water is at a higher temperature than the design point of the chiller. Therefore, an experiment was carried out using the city water for cooling. The results show that an enhancement in the chiller COP by 40% and the chilling power by 17% has been achieved when the city water was 27.7°C.  相似文献   

9.
After energy, water is the most critical commodity to be made available to people to keep them alive. Saudi Arabia has vast land and people are living in all regions. Most of these are connected to national grid but some are not, especially in remote areas like in the north, south, and west south. Pumping water in remote areas for domestic needs like agriculture and animals beside human needs is essential and require regular power supply. The present idea of wind-PV-Battery hybrid power system based on 100% renewable source is being proposed to utilize and tested in some of the regions on experimental bases. Of the five locations chosen for the purpose, namely Dhahran, Riyadh, Jeddah, Guriat and Nejran, some are good from both wind and solar intensity point of view some have good winds only and some good solar only. Nearly optimal size of PV-Wind water pumping system is determined for each of these sites considering the availability of solar and wind energy distributions throughout the year in these sites. It is shown that the monthly total water pumping capacity when using nearly optimal PV-Wind water pumping system is fairly uniform throughout the year except for the sites of Guriat and Riyadh. In these sites higher water pumping capacity is observed during the spring and summer months. On the other hand the cost of underground water pumping is found to vary between 6 to 12 US¢/m3 for the five sites considered.  相似文献   

10.
ABSTRACT

According to the structure of photovoltaic/phase change material (PV/PCM), the mechanism of internal heat transfer, transmission, storage, and temperature control is analyzed, and a two-dimensional finite element analysis model of PV/PCM structure is established. This study is carried out on the effect of PCM thermal conductivity on internal temperature distribution characteristics of PV/PCM and temperature control characteristics of solar cells. The results show that the increase in thermal conductivity of PCM can prolong the temperature control time of solar cell in PV/PCM system, for example, when the thermal conductivity is increased from 0.2 W/(m·K) to1.5 W/(m·K) under a thickness of 4 cm, the duration when PV/PCM solar cell temperature is controlled below 40°C and extended from 52 min to 184 min. In addition, PV/PCM experimental prototypes are designed with the LA-SA-EG composite PCM peak melting point of 46°C and thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K), respectively. The results indicate that compared with PCM-free solar cells, the maximum temperature of PV/PCM prototype solar cells with thermal conductivity of 0.8 W/(m·K) and 1.1 W/(m·K) is reduced by 10.8°C and 4.6°C, respectively, with average output power increased by 4.1% and 2.2%, respectively, under simulated light sources. Under natural light conditions, the average output power is increased by 6.9% and 4.3%, respectively. The results provide theoretical and experimental basis for the optimization of PV/PCM design by changing the thermal conductivity of PCM.  相似文献   

11.
The suitable design is the most important key to a cost-effective solar air heater. Although there are many techniques that have been proposed to improve the solar air heaters’ performance by means of different turbulence promoters, they cannot ensure a compromise between the cost and the effectiveness. The aim of this study is to find simple and tolerable solution to get rid of the inconvenience resulting from the widely adopted heat-transfer-enhancement techniques by providing an optimized solar air heater design. The proposed design consists of a slightly curved smooth flow channel with an absorber plate of convex shape. A prototype of a curved solar air heater of 1.28 m2 collector area was built and tested under summer outdoor conditions in Biskra (Algeria). The performance was evaluated in terms of thermal and effective efficiency for mass flow rates of 0.0172, 0.029, and 0.0472 kg/sm2. It is observed that the overall efficiency of this solar air heater is considerably higher in comparison with the efficiency range of the conventional smooth flat plate heaters reported in the literature for similar operating conditions.  相似文献   

12.
A new system composed of a sequential flat plate and parabolic dish solar collector was applied to enhance the solar desalination productivity. Heated saline water was desalinated using the evaporation/condensation principle and an effort was made to achieve higher distillate production compared to previous studies. Desalination efficiency values were calculated between 23% and 57%. Maximum desalinated water productions were obtained as 1,038 mL/m2.h in autumn and 1,402 mL/m2.h in summer. The cost of solar desalination system was found as economically feasible with 3 years’ payback period and the produced water cost of 0.014 $/L. Physicochemical analyses revealed that as a result of the desalination process, salinity level decreased from 35.6‰ to 0.0–0.1‰, chloride concentration decreased from 21,407 mg/L to 10 mg/L, and electrical conductivity decreased from 53.1 mS/cm to 0.11 mS/cm.  相似文献   

13.
This paper analyses actual performance of three grid-connected photovoltaic systems based on different silicon technologies, installed at the faculty of sciences of Agadir. The outdoor facilities consist of 2.04 kWp of mono crystalline (m-Si), 1.86 kWp of amorphous (μcSi/a-Si:H), and 2.04 kWp of multi crystalline (mc-Si) silicon PV systems. Datasets were collected during one entire year under real measured irradiation and ambient temperature conditions. The performance of these roof mounted PV systems was conducted on daily and monthly bases. Parameters like annual specific yield, system efficiency, and performance ratio were evaluated and found to be 1827 kWh/kWp.year, 20.9% and 80.2% for amorphous, 1863 kWh/kWp.year, 21.3% and 80.7%, for mono crystalline and 1895 kWh/kWp.year, 21.7% and 82.2% for multi crystalline.  相似文献   

14.
15.
The performance of the designed tilted wick solar water distillation-cum-drying unit has been tested at water flow rates of 50 and 65 ml/min in the distillation unit. Effect of water flow rates on the heat transfer coefficients of distillation and drying unit for drying ginger has been evaluated. The energy and exergy efficiency of the distillation system have also been evaluated. Average distillates of 2.36 and 2.2 l/m2 were collected from the tilted wick solar still at flow rates of 50 and 65 ml/min, respectively. Large variation in convective and evaporative heat transfer coefficients of distillation unit has been observed at given water flow rates. Water flow rate in the distillation unit significantly affects the performance of the drying unit. Average convective heat transfer coefficients of 6.56 and 3.75 W/m2 oC have been observed for drying ginger at flow rates of 50 and 65 ml/min, respectively. Energy and exergy efficiency of the distillation unit have been found to be nearly 19% and 0.9%, respectively. Experimental uncertainty has also been evaluated for distillation and drying units. The distillate cost for the developed distillation-cum-drying unit is calculated as $0.03729/l along with dried ginger of about 2.5 kg/m2/day.  相似文献   

16.
In the project of the solar systems, the values of the solar radiation of a region must be known. The global solar radiation measurements are performed by the Turkish Meteorological Service in Turkey, while the diffuse solar radiation measurements are unavailable. In this study, some new models for predicting the monthly average daily diffuse solar radiation on a horizontal surface for Erzincan, Turkey are developed using satellite data. The evaluation of the models is carried out with the statistical analysis methods of mean bias error (MBE), root mean square error (RMSE) and correlation coefficient (r). The results are proved that the correlation equations obtained in here can be used to forecast diffuse solar radiation reasonably well.  相似文献   

17.
Solar radiation is a major sustainable and clean energy resource, and use of solar radiation is expected to increase. The utilization efficiency of solar energy varies with the relative proportions of the direct and diffuse components that compose total solar radiation and with the slope and aspect of the irradiated surface. The purpose of this paper is to develop a simple method for estimating diffuse and direct solar radiation at sites with observation of only total solar radiation. An existing model for estimating diffuse radiation, i.e., a linear relationship between the diffuse fraction (the ratio of diffuse radiation to total solar radiation) and the clearness index (the ratio of total solar radiation to extraterrestrial radiation), is applied to 7 sites across the continental United States with observations of diffuse and total radiation. The linear model shows good monthly performance. The model parameters (slope and interception) show a strong seasonal pattern that exhibits small variation across the 7 sites; therefore, the average values of the two monthly parameters may be used for estimating diffuse radiation for other locations with observations of total radiation.  相似文献   

18.
Experimental study was performed on a single basin active solar distillation system augmented with a solar collector using evacuated solar tubes. Field tests were conducted over several days under the climatic conditions of West Texas to evaluate the effect evacuated solar tubes have on the daily distillate yield rate. To investigate the feasibility of the solar tubes, active and passive solar stills with and without exterior insulation were examined. The maximum daily production rate for the active distillation system using evacuated solar tubes and the passive distillation system was 3.6 and 1.4 kg/m2day, respectively. The results showed the augmentation of the still with evacuated solar tubes increased its production capacity by a factor of 2.63. It also increased the maximum temperature of the water in the still basin by at least 20 °C. Economic analysis shows that it is feasible to use evacuated tubular collector coupled solar still as an alternative means for reclaiming water in farmlands with a payback period of approximately 6 years.  相似文献   

19.
An emissions inventory and the AERMOD View dispersion model were used to estimate the concentrations and the potential effects of carbon monoxide (CO) from diesel engine electric power generators operated by and providing electricity to a textile factory in Nigeria on its host air shed. The CO emissions from simultaneous operations of all of the electric power generators in the factory resulted in: 1‐hr average CO emissions of 4.2 to 54.5 micrograms per cubic meters (μg/m3) and 24‐hr average CO emissions of 0.3 to 20.9 μg/m3. The estimated 1‐hr averaging period maximum ground‐level concentrations of CO were deposited within the factory, while the 24‐hr maximum ground‐level concentrations are estimated at a distance 90 meters (m) from the factory in a southeast direction. The ground‐level concentrations of CO emanating from the textile factory are within the stipulated ambient air quality standards.  相似文献   

20.
A data analysis of three major Korean cities was conducted to assess roadside inhalable particulate matter 10 μm or smaller in aerodynamic diameter (PM10), including temporal and meteorological variations, over a recent period of 4 to 6 years. The yearly roadside PM10 concentrations presented a well-defined increasing trend or no trend depending on the roadside monitoring station. Most mean values exceeded or approximated the Korean standard of 70 μg/m3 per year for PM10. A representative roadside diurnal trend was characterized by a distinct morning maximum. In most cases, the Sunday roadside concentrations were similar to or somewhat lower than the weekday concentrations, and the PM10 concentrations presented a well-defined seasonal variation, with the maximum concentration in March. The monthly maximum concentrations observed in March were most likely attributable to Asian dust storms. In two metropolitan cities (Seoul and Busan), the frequency of days with roadside PM10 concentrations exceeding the standard of 150μg/m3 per 24 h was much lower for the roadside monitoring stations than for the residential monitoring station, whereas in the third city (Daegu), this result was reversed. Interestingly, the average maximum concentrations observed for the roadside sites in Seoul and Busan during March were higher than those for the residential sites, suggesting that the roadside concentrations responded more to the dust storms than the residential areas. The relationship between the pollutant concentrations and five important meteorological parameters (solar radiation, wind speed, air temperature, relative humidity, and precipitation) showed that the number and type of meteorological variables included in the equations varied according to the monitoring station or season. Finally, the current results confirmed that attention should be given to the PM10 exposure of residents living near roadways.  相似文献   