1.
As part of an international research project, aerosol samples were collected by several filter-based devices on Nuclepore polycarbonate membrane, Teflon membrane and quartz fibre filters over separate daylight periods and nights, and on-line aerosol measurements were performed by TEOM and aethalometer within an urban canyon (kerbside) and at a near-city background site in Budapest, Hungary from 23 April–5 May 2002. Aerosol masses in PM2.0, PM10–2.0, PM2.5, PM10 size fractions and of TSP were determined gravimetrically; atmospheric concentrations of organic (OC) and elemental carbon (EC) for PM2.5 (or PM2.0), PM10 fractions and for TSP were measured by thermal–optical transmission method. Repeatability of the mass determination by Nuclepore filters seems to be 5–6%. Collections on Teflon filters yielded smaller mass on average by 8(±12)% than that for the Nuclepore filters. Quartz filters overestimated the PM10 mass in comparison with the Nuclepore filters due primarily to sampling artefacts on average by 10(±16)% at the kerbside. Tandem filter set-ups were utilised for correcting the sampling artefacts for OC by subtraction method. At the kerbside, the aerosol mass was made up on average of 35(±4)% of organic matter (OM) in the PM10 fraction, while the contribution of OM to the PM2.5 mass was 43(±9)%. At the background, OM also accounted for 43(±13)% of the PM2.0 mass. On average, EC made up 14(±6)%, 7(±2)% and 4.5(±1.1)% of the mass in the PM2.5, PM10 fractions and TSP, respectively, at the kerbside; while its contribution was only 2.1(±0.5)% in the PM2.0 fraction in the near-city background. Temporal variability for PM mass, OC and EC concentrations was related to road traffic, local meteorology and long-range transport of air masses. It was concluded that a direct coupling between the atmospheric concentration levels and vehicle circulation can be identified within the urban canyon, nevertheless, the local meteorology in particular and long-range transport of air masses have much more influence on the air quality than changes in the source intensity of road traffic. Concentration ratios of OC/EC were evaluated, and the amount of secondary organic aerosol (SOA) was estimated by using EC as tracer for the primary OC emissions. Mean contribution and standard deviation of the SOA to the OM in the PM2.5 size fraction at the kerbside over daylight periods and nights were of 37(±18) and 46(±16)%, respectively.  相似文献   

2.
Water-soluble organic carbon (WSOC) and atmospheric humic-like substances (HULIS) were investigated for urban PM2.5-fraction aerosol samples, which were collected with the tandem filter method on quartz fibre filters over a non-heating spring season. Sampling artefacts were of importance for all organic chemical fractions, and the back-to-front-filter concentration ratios were on average 28% for WSOC and 17% for HULIS and organic carbon (OC). The difference in the ratios indicates that the water-soluble organics play a more important role in adsorptive artefacts than the organic matter (OM) in general. The results emphasize the need for an appropriate sampling and/or correction method for measuring particulate organic substances in urban environments. The corrected atmospheric concentration of HULIS, obtained by subtracting the back-filter from the front-filter data, was on average 2 μg m−3; which represented 6% of the mean PM2.5 particulate mass, and it made up 45% of the secondary OC. The HULIS carbon accounted for 20% of the OC and 62% of the WSOC, while WSOC made up 32% of OC. The major element composition of HULIS, expressed in molar ratios, was C:H:O:N=22:32:10:1. The molar H/C ratio of 1.49 implies the presence of unsaturated organic compounds, although these were depleted in comparison with rural aerosol or standard fulvic acids. The molar O/C ratio of 0.47 indicates the existence of oxygenated functional groups; comparison to rural aerosol suggests that the (fresh) urban-type aerosol is less oxidized (and, therefore, less water soluble as well) than the rural one. The OM/OC mass conversion factor for the isolated (water-soluble) HULIS was derived to be 1.81. It was inferred from comparisons with published data that there are substantial differences in abundance and chemical composition of HULIS for different environments.  相似文献   

3.
Aerosol carbon sampling methods and biases were evaluated during the California Regional PM10/PM2.5 Air Quality Study (CRPAQS) and Fresno Supersite programs. PM2.5 sampling was conducted using Desert Research Institute (DRI) sequential filter samplers (SFS) from December 1999 through February 2001 at two urban sites (Fresno and Bakersfield), one regional transport site (Angiola), and two boundary sites (Bethel Island and Sierra Nevada Foothills) during CRPAQS in the San Joaquin Valley (SJV). Additional filter-based sampling was done in Fresno as part of the US Environmental Protection Agency (EPA) Supersites program. Organic carbon (OC) and elemental carbon (EC) concentrations were higher during winter (December-February) than summer (June-August) and this trend was most pronounced at Fresno and Bakersfield. OC and EC displayed similar diurnal trends during winter and summer at Fresno and during winter at Angiola. The diurnal pattern at Angiola reflected the transport of secondary pollutants to the site. Collocated measurements of OC and EC on undenuded quartz-fiber filters were made at Fresno with the DRI SFS and the Andersen FRM and RAAS samplers. All average differences in OC between samplers were less than their respective measurement uncertainties. Positive and negative OC biases were evaluated at Fresno using the Andersen RAAS sampler with carbon-denuded and undenuded channels with Teflon-membrane and quartz-fiber filter pairs. Differences between the denuded particle OC and that obtained by subtracting the quartz-behind-Teflon or quartz-behind-quartz OC from the undenuded quartz-fiber front filter were less than twice their measurement uncertainties in most cases. Particulate OC in the denuded channel agreed most closely with the difference between undenuded front and backup quartz-fiber OC.  相似文献   

4.
Ammonium nitrate and semivolatile organic material (SVOM) are significant components of fine particles in urban atmospheres. These components, however, are not properly determined with methods such as the fine particulate matter (PM2.5) Federal Reference Method (FRM) or other single filter samplers because of significant losses of semivolatile material (SVM) from particles collected on the filter during sampling. The R&P tapered element oscillating microbalance (TEOM) monitor also does not measure SVM, because this method heats the sample to remove particle bound water, which also results in evaporation of SVM. Recent advances in monitoring techniques have resulted in samplers for both integrated and continuous measurement of total PM2.5, including the particle concentrator-Brigham Young University organic sampling system (PC-BOSS), the real-time total ambient mass sampler (RAMS), and the R&P filter dynamics measurement system (FDMS) TEOM monitor. Results obtained using these samplers have been compared with those obtained with either a PM2.5 FRM sampler or a TEOM monitor in studies conducted during the past five years. These studies have shown the following: (1) the PC-BOSS, RAMS, and FDMS TEOM are all comparable. Each instrument measures both the nonvolatile material and the SVM. (2) The SVM is not retained on the heated filter of a regular TEOM monitor and is not measured by this sampling technique. (3) Much of the SVM is also lost during sampling from single filter samplers such as the PM2.5 FRM sampler. (4) The amount of SVM lost from single filter samplers can vary from less than one-third of that lost from heated TEOM filters during cold winter conditions to essentially all during warm summer conditions. (5) SVOM can only be reliably collected using an appropriate denuder sampler. (6) A PM2.5 speciation sampler can be easily modified to a denuder sampler with filters that can be analyzed for semivolatile organic carbon (OC), nonvolatile OC, and elemental carbon using existing OC/elemental carbon analytical techniques. The research upon which these statements are based for various urban studies are summarized in this paper.  相似文献   

5.
The chemical composition of PM10 and PM2.5 was studied during summer and winter sampling campaigns in South and West Europe (Barcelona, Spain, and Ghent, Belgium). The chemical composition of the PM10 aerosol was markedly different in the two regions, even at similar PM10 levels. The chemical composition of PM2.5 showed more similarities. The contribution of mineral matter was higher in Barcelona (on average 12% of the PM2.5 mass), whereas the contribution from sea salt was higher in Ghent (4% of PM2.5). Volatilisation of NH4+ from the filters (negative artefact) was observed in both regions, although the extent of this artefact showed regional differences (0–4% and 22–38% of the NH4+ mass in Ghent and Barcelona, respectively) and had no impact on the compliance with EU limit values. The number of exceedances of the PM10 limit value and an arbitrary PM2.5 limit of 25 μg m−3 was calculated by subtracting the mineral fraction (natural or anthropogenic in origin) from the bulk PM load, and this resulted in the elimination of the PM10 exceedances in Barcelona, and a reduction of one out of three exceedances in Ghent. The subtraction of sea-salt aerosol had no effect in Barcelona, and it removed one exceedance in each size fraction in Ghent. Exceedances of the PM10 daily limit value in Ghent coincided with back-trajectories originating from Eastern and Southern European regions. The origin of the exceedances in Barcelona during the campaigns was mostly local.  相似文献   

6.
The concentrations of monosaccharide anhydrides (levoglucosan, mannosan, galactosan) in PM1 and PM2.5 aerosol samples were measured in Brno and ?lapanice in the Czech Republic in winter and summer 2009. 56 aerosol samples were collected together at both sites to investigate the different sources that contribute to aerosol composition in studied localities. Daily PM1 and PM2.5 aerosol samples were collected on pre-fired quartz fibre filters.The sum of average atmospheric concentration of levoglucosan, mannosan and galactosan in PM1 aerosol in ?lapanice and Brno during winter was 513 and 273 ng m?3, while in summer the sum of average atmospheric concentration of monosaccharide anhydrides (MAs) was 42 and 38 ng m?3, respectively. The sum of average atmospheric concentration of MAs in PM1 aerosol formed 71 and 63% of the sum of MA concentration in PM2.5 aerosol collected in winter in ?lapanice and Brno, whereas in summer the sum of average atmospheric concentration of MAs in PM1 aerosol formed 45 and 43% of the sum of MA concentration in PM2.5 aerosol in ?lapanice and Brno, respectively.In winter, the sum of MAs contributed significantly to PM1 mass ranging between 1.37% and 2.67% of PM1 mass (Brno – ?lapanice), while in summer the contribution of the sum of MAs was smaller (0.28–0.32%). Contribution of the sum of MAs to PM2.5 mass is similar both in winter (1.37–2.71%) and summer (0.44–0.55%).The higher concentrations of monosaccharide anhydrides in aerosols in ?lapanice indicate higher biomass combustion in this location than in Brno during winter season. The comparison of levoglucosan concentration in PM1 and PM2.5 aerosol shows prevailing presence of levoglucosan in PM1 aerosol both in winter (72% on average) and summer (60% on average).The aerosol samples collected in ?lapanice and Brno in winter and summer show comparable contributions of levoglucosan, mannosan and galactosan to the total amount of monosaccharide anhydrides in both aerosol size fractions. Levoglucosan was the most abundant monosaccharide anhydride with a relative average contribution to the total amount of MAs in the range of 71–82% for PM1 aerosols and 52–79% for PM2.5 aerosols.  相似文献   

7.
The organic carbon (OC)/elemental carbon (EC) tracer method is applied to the Pittsburgh, PA, area to estimate the contribution of secondary organic aerosol (SOA) to the monthly average concentration of organic particulate matter (PM) during 1995. An emissions inventory is constructed for the primary emissions of OC and EC in the area of interest. The ratio of primary emissions of OC to those of EC ranges between 2.4 in the winter months and 1.0 in the summer months. A mass balance model and ambient measurements were used to assess the accuracy of the emissions inventory. It is estimated to be accurate to within 50%. The results from this analysis show a strong monthly dependence of the SOA contribution to the total organic PM concentration, varying from near zero during winter months to as much as 50% of the total OC concentration in the summer.  相似文献   

8.
Abstract

The organic carbon (OC)/elemental carbon (EC) tracer method is applied to the Pittsburgh, PA, area to estimate the contribution of secondary organic aerosol (SOA) to the monthly average concentration of organic particu-late matter (PM) during 1995. An emissions inventory is constructed for the primary emissions of OC and EC in the area of interest. The ratio of primary emissions of OC to those of EC ranges between 2.4 in the winter months and 1.0 in the summer months. A mass balance model and ambient measurements were used to assess the accuracy of the emissions inventory. It is estimated to be accurate to within 50%. The results from this analysis show a strong monthly dependence on SOA contribution to the total organic PM concentration, varying from near zero during winter months to 50% or more of the total OC concentration in the summer.  相似文献   

9.
An investigation of high volume particle sampling and sample handling procedures was undertaken to evaluate variations of protocols being used by the U.S. Environmental Protection Agency. These protocols are used in urban ambient air studies which collect ambient and source samples for subsequent mutagenicity analysis of the organic extracts of the aerosol fraction. Specific protocol issues investigated include: (a) duration of sampling period, (b) type of filter media used to collect air particles, (c) necessity for cryogenic field site storage and dry ice shipping of filter samples, and (d) sample handling at the receiving laboratory. Six PM10 Hi-Vol samplers were collocated at an urban site in downtown Durham, North Carolina and operated simultaneously to evaluate 12 h versus 24 h collection periods and filter media choices of glass fiber, Teflon impregnated glass fiber (TIGF), and quartz fiber. Filters from the samplers plus field blanks were collected during each of 25 sampling periods. TIGF filters from two samplers were immediately placed on dry ice in the field and transported directly to cryogenic storage. TIGF, quartz, and glass fiber filters from three samplers were transported at ambient and maintained at room temperature for three to six days prior to cryogenic storage. One TIGF sample, which was collected on a previously tared filter, was subjected to controlled environment equilibration (40 percent relative humidity, 22 degrees C) for 8 to 24 h and weighed prior to cryogenic storage. All filters were subsequently stored at -70 degrees C to -80 degrees C prior to a one-time extraction and Salmonella (Ames) mutagenicity bioassay of the entire sample set.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

10.
Sampling and analysis of carbonaceous compounds in particulate matter presents a number of difficulties related to artefacts during sampling and to the distinction between organic (OC) and elemental carbon (EC) during analysis. Our study reports on a comparative analysis of OC, EC and WSOC (water-soluble organic carbon) concentrations, as well as sampling artefacts, for PM2.5 aerosol in three European cities (Amsterdam, Barcelona and Ghent) representing Southern and Western European urban environments. Comparability of results was ensured by using a single system for sample analysis from the different sites. OC and EC concentrations were higher in the vicinity of roads, thus having higher levels in Amsterdam (3.9–6.7 and 1.7–1.9 μg m−3, respectively) and Barcelona (3.6–6.9 and 1.5–2.6 μg m−3) than in Ghent (2.7–5.4 and 0.8–1.2 μg m−3). A relatively larger influence of secondary organic aerosols (SOA), as deduced from a larger OC/EC ratio, was observed in Ghent. In absolute sense, WSOC concentrations were similar at the three sites (1.0–2.3 μg m−3). Positive artefacts were higher in Southern (11–16% of the OC concentration in Barcelona) than in Western Europe (5–12% in Amsterdam, 5–7% in Ghent). During special episodes, the contribution of carbonaceous aerosols from non-local sources accounted for 67–69% of the OC concentration in Western Europe, and for 44% in Southern Europe.  相似文献   

11.
The Aerosol Research and Inhalation Epidemiology Study (ARIES) was designed to provide high-quality measurements of PM2.5, its components, and co-varying pollutants for an air pollution epidemiology study in Atlanta, GA. Air pollution epidemiology studies have typically relied on available data on particle mass often collected using filter-based methods. Filter-based PM2.5 sampling is susceptible to both positive and negative errors in the measurement of aerosol mass and particle-phase component concentrations in the undisturbed atmosphere. These biases are introduced by collection of gas-phase aerosol components on the filter media or by volatilization of particle phase components from collected particles. As part of the ARIES, we collected daily 24-hr PM2.5 mass and speciation samples and continuous PM2.5 data at a mixed residential-light industrial site in Atlanta. These data facilitate analysis of the effects of a wide variety of factors on sampler performance. We assess the relative importance of PM2.5 components and consider associations and potential mechanistic linkages of PM2.5 mass concentrations with several PM2.5 components. For the 12 months of validated data collected to date (August 1, 1998-July 31, 1999), the monthly average Federal Reference Method (FRM) PM2.5 mass always exceeded the proposed annual average standard (12-month average = 20.3 +/- 9.5 micrograms/m3). The particulate SO4(2-) fraction (as (NH4)2SO4) was largest in the summer and exceeded 50% of the FRM mass. The contribution of (NH4)2SO4 to FRM PM2.5 mass dropped to less than 30% in winter. Particulate NO3- collected on a denuded nylon filter averaged 1.1 +/- 0.9 micrograms/m3. Particle-phase organic compounds (as organic carbon x 1.4) measured on a denuded quartz filter sampler averaged 6.4 +/- 3.1 micrograms/m3 (32% of FRM PM2.5 mass) with less seasonal variability than SO4(2-).  相似文献   

12.
Boiler briquette coal versus raw coal: Part I--Stack gas emissions   总被引:1,自引:0,他引:1  
Stack gas emissions were characterized for a steam-generating boiler commonly used in China. The boiler was tested when fired with a newly formulated boiler briquette coal (BB-coal) and when fired with conventional raw coal (R-coal). The stack gas emissions were analyzed to determine emission rates and emission factors and to develop chemical source profiles. A dilution source sampling system was used to collect PM on both Teflon membrane filters and quartz fiber filters. The Teflon filters were analyzed gravimetrically for PM10 and PM2.5 mass concentrations and by X-ray fluorescence (XRF) for trace elements. The quartz fiber filters were analyzed for organic carbon (OC) and elemental carbon (EC) using a thermal/optical reflectance technique. Sulfur dioxide was measured using the standard wet chemistry method. Carbon monoxide was measured using an Orsat combustion analyzer. The emission rates of the R-coal combustion (in kg/hr), determined using the measured stack gas concentrations and the stack gas emission rates, were 0.74 for PM10, 0.38 for PM2.5, 20.7 for SO2, and 6.8 for CO, while those of the BB-coal combustion were 0.95 for PM10, 0.30 for PM2.5, 7.5 for SO2, and 5.3 for CO. The fuel-mass-based emission factors (in g/kg) of the R-coal, determined using the emission rates and the fuel burn rates, were 1.68 for PM10, 0.87 for PM2.5, 46.7 for SO2, and 15 for CO, while those of the BB-coal were 2.51 for PM10, 0.79 for PM2.5, 19.9 for SO2, and 14 for CO. The task-based emission factors (in g/ton steam generated) of the R-coal, determined using the fuel-mass-based emission factors and the coal/steam conversion factors, were 0.23 for PM10, 0.12 for PM2.5, 6.4 for SO2, and 2.0 for CO, while those of the BB-coal were 0.30 for PM10, 0.094 for PM2.5, 2.4 for SO2, and 1.7 for CO. PM10 and PM2.5 elemental compositions are also presented for both types of coal tested in the study.  相似文献   

13.
The PM(2.5) concentration and its elemental composition were measured in the Cincinnati metropolitan area, which is characterized by intense highway traffic. The spatial and temporal variations were investigated for various chemical elements that contributed to the PM(2.5) fraction during a 1-year-long measurement campaign (December 2001-November 2002). The ambient aerosol monitoring was performed in 11 locations around the city during nine measurement cycles. During each cycle, four Harvard-type impactors were operating in parallel in specific locations to explore various factors affecting the PM(2.5) elemental concentrations. The sampling was performed during business days, thus assuring traffic uniformity. The 24-h PM(2.5) samples were collected on Teflon and quartz filters. Teflon filters were analyzed by X-ray fluorescence (XRF) analysis while quartz filters were analyzed by thermal-optical transmittance (TOT) analysis. In addition to PM(2.5) measurements, particle size-selective sampling was performed in two cycles using micro-orifice uniform deposit impactor; the collected fractionated deposits were analyzed by XRF. It was found that PM(2.5) concentration ranged from 6.70 to 48.3 mug m(-3) and had low spatial variation (median coefficient of variation, CV=11.3%). The elemental concentrations demonstrated high spatial variation, with the median CV ranged from 38.2% for Fe to 68.7% for Ni. For traffic-related trace metals, the highest concentration was detected in the city center site, which was close to a major highway. The particle size selective measurement revealed that mass concentration of the trace metals, such as Zn, Pb, Ni, as well as that of sulfur reach their peak values in the particle size range of 0.32-1.0 mum. Meteorological parameters and traffic intensity were not found to have a significant influence on the PM(2.5) elemental concentrations.  相似文献   

14.
Seasonal elemental carbon (EC) and organic carbon (OC) concentration levels in PM2.5 samples collected in Milan (Italy) are presented and discussed, enriching the world-wide database of carbonaceous species in fine particulate matter (PM). High-volume PM2.5 sampling campaigns were performed from August 2002 through December 2003 in downtown Milan at an urban background site. Compared to worldwide average concentrations, in Milan warm-season OC and both warm- and cold-season EC are relatively low; conversely, cold-season OC concentrations are rather high. Consequently, high values for the OC/EC ratio are observed, especially in the winter period. The relation between OC/EC ratio values and wind direction is investigated, pointing out that the highest ratios are associated to winds blowing from those nearby areas where wood consumption for domestic heating is larger. Information on the OC partitioning between its primary and secondary fraction are derived by means of the EC-tracer method and principal component analysis. In the warm-season, OC is mainly of secondary origin, secondary organic aerosol (SOA) accounting for about 84% of the particulate organic matter and 25–28% of the PM2.5 mass. For the cold season the full application of the EC-tracer method was not possible and the primary organic aerosol deriving from traffic could only be estimated. However, principal component analysis (PCA) suggest a prevailing primary origin for OC, thus raising the attention on space heating emissions, and on wood combustion in particular, for air quality control. The role of traffic emissions on PM2.5 concentration levels, as a primary source, are also assessed: EC and primary organic matter from traffic account for a warm-season 30% and a cold-season 7% of the total carbon in PM2.5, that is for about 10% and 6% of PM2.5 mass, respectively. This latter small primary contribution estimated for the cold-season points out that stationary sources, which were not thought to play a significant role on PM concentration levels, may conversely be as much responsible for ambient particulate pollution.  相似文献   

15.
The Monterrey Metropolitan Area (MMA) has shown a high concentration of PM2.5 in its atmosphere since 2003. The contribution of possible sources of primary PM2.5 and its precursors is not known. In this paper we present the results of analyzing the chemical composition of sixty 24-hr samples of PM2.5 to determine possible sources of PM2.5 in the MMA. The samples were collected at the northeast and southeast of the MMA between November 22 and December 12, 2007, using low-volume devices. Teflon and quartz filters were used to collect the samples. The concentrations of 16 airborne trace elements were determined using x-ray fluorescence (XRF). Anions and cations were determined using ion chromatography. Organic carbon (OC) and elemental carbon (EC) were determined by thermal optical analysis. The results show that Ca had the maximum mean concentration of all elements studied, followed by S. Enrichment factors above 50 were calculated for S, Cl, Cu, Zn, Br and Pb. This indicates that these elements may come from anthropogenic sources. Overall, the major average components of PM2.5 were OC (41.7%), SO4(2-) (22.9%), EC (7.4%), crustal material (11.4%), and NO3- (12.6%), which altogether accounted for 96% of the mass. Statistically, we did not find any difference in SO4(2-) concentrations between the two sites. The fraction of secondary organic carbon was between 24% and 34%. The results of the factor analysis performed over 10 metals and OC and EC show that there are three main sources of PM2.5: crustal material and vehicle exhaust; industrial activity; and fuel oil burning. The results show that SO4(2-), OC, and crustal material are important components of PM2.5 in MMA. Further work is necessary to evaluate the proportion of secondary inorganic and organic aerosol in order to have a better understanding of the sources and precursors of aerosols in the MMA.  相似文献   

16.
PM2.5 samples were collected at five sites in Guangzhou and Hong Kong, Pearl River Delta Region (PRDR), China in both summer and winter during 2004–2005. Elemental carbon (EC) and organic carbon (OC) in these samples were measured. The OC and EC concentrations ranked in the order of urban Guangzhou > urban Hong Kong > background Hong Kong. Total carbonaceous aerosol (TCA) contributed less to PM2.5 in urban Guangzhou (32–35%) than that in urban Hong Kong (43–57%). The reason may be that, as an major industrial city in South China, Guangzhou would receive large amount of inorganic aerosol from all kinds of industries, however, as a trade center and seaport, urban Hong Kong would mainly receive organic aerosol and EC from container vessels and heavy-duty diesel trucks. At Hong Kong background site Hok Tsui, relatively lower contribution of TCA to PM2.5 may result from contributions of marine inorganic aerosol and inland China pollutant. Strong correlation (R2=0.76–0.83) between OC and EC indicates minor fluctuation of emission and the secondary organic aerosol (SOA) formation in urban Guangzhou. Weak correlation between OC and EC in Hong Kong can be related to the impact of the long-range transported aerosol from inland China. Averagely, secondary OC (SOC) concentrations were 3.8–5.9 and 10.2–12.8 μg m−3, respectively, accounting for 21–32% and 36–42% of OC in summer and winter in Guangzhou. The average values of 4.2–6.8% for SOA/ PM2.5 indicate that SOA was minor component in PM2.5 in Guangzhou.  相似文献   

17.
Filter-based methods for sampling aerosols are subject to great uncertainty if the gas–particle interactions on filter substrates are not properly handled. Sampling artifacts depend on both meteorological conditions and the chemical mix of the atmosphere. Despite numerous of studies on the subject, very few have evaluated filter-based methods in the Asian environments. This paper reports the results of a comparison of the performances of two filter-based samplers, including a Thermo Anderson Chemical Speciation Monitor (RAAS) and a honeycomb denuder filter-pack system, a Micro Orifice Uniform Deposit Impactor (MOUDI) and a real-time ambient ion monitor (AIM, URG9000B) in measuring atmospheric concentrations of PM2.5 sulfate and nitrate. Field studies were conducted at an urban site in Jinan, Shandong province, during the winter of 2007 and at a rural site near Beijing in the summer of 2008. The AIM was first compared with the honeycomb denuder filter-pack system which was considered to have minimal sampling artifacts. After some modifications made to it, the AIM showed good performance for both sulfate and nitrate measurement at the two sites and was then used to evaluate other instruments. For the un-denuded RAAS, the extent of sampling artifacts for nitrate on quartz filters was negligible, while that on Teflon filters was also minimal at high nitrate concentrations (>10 μgm?3); however, loss through evaporation was significant (~75%) at low nitrate concentrations under hot summer conditions. The MOUDI using aluminum substrates suffered a significant loss of nitrate (50–70%) under summer conditions due to evaporation. Considering that the aluminum substrates are still being widely used to obtain size-resolved aerosol compositions because of their low cost and accurate mass weighed, caution should be taken about the potential significant under determination of semi-volatile components such as ammonium nitrate.  相似文献   

18.
Fine particulate matter (PM2.5) samples were simultaneously collected on Teflon and quartz filters between February 2010 and February 2011 at an urban monitoring site (CAMS2) in Dhaka, Bangladesh. The samples were collected using AirMetrics MiniVol samplers. The samples on Teflon filters were analyzed for their elemental composition by PIXE and PESA. Particulate carbon on quartz filters was analyzed using the IMPROVE thermal optical reflectance (TOR) method that divides carbon into four organic carbons (OC), pyrolized organic carbon (OP), and three elemental carbon (EC) fractions. The data were analyzed by positive matrix factorization using the PMF2 program. Initially, only total OC and total EC were included in the analysis and five sources, including road dust, sea salt and Zn, soil dust, motor vehicles, and brick kilns, were obtained. In the second analysis, the eight carbon fractions (OC1, OC2, OC3, OC4, OP, EC1, EC2, EC3) were included in order to ascertain whether additional source information could be extracted from the data. In this case, it is possible to identify more sources than with only total OC and EC. The motor vehicle source was separated into gasoline and diesel emissions and a fugitive Pb source was identified. Brick kilns contribute 7.9 μg/m3 and 6.0 μg/m3 of OC and EC, respectively, to the fine particulate matter based on the two results. From the estimated mass extinction coefficients and the apportioned source contributions, soil dust, brick kiln, diesel, gasoline, and the Pb sources were found to contribute most strongly to visibility degradation, particularly in the winter.

Implications: Fine particle concentrations in Dhaka, Bangladesh, are very high and cause significant degradation of urban visibility. This work shows that using carbon fraction data from the IMPROVE OC/EC protocol provides improved source apportionment. Soil dust, brick kiln, diesel, gasoline, and the Pb sources contribute strongly to haze, particularly in the winter.  相似文献   

19.
Organic carbon (OC) is one of the major components of ambient PM2.5 (particulate matter [PM] < or = 2.5 microm in aerodynamic diameter) and a significant portion of OC is from secondary organic aerosol (SOA) formation in the southeastern United States. Various approaches (based on measurement and modeling results) are applied to estimate secondary organic carbon (SOC) and its origins in the region. SOC estimates by various methods are consistent as to clear seasonal variation (i.e., relatively higher SOC in summer) and little spatial variability (i.e., a regional characteristic of SOC). However, there are differences as to the origins of SOC. SOA organic tracer and emission-based modeling studies indicate that the biogenic origin of SOC is dominant in the Southeast, showing that biogenic-origin SOC accounts for 90% of SOC in summer and more than 70% even in other seasons. However, results from other studies suggest that the anthropogenic origin of SOC is dominant, significant amounts of anthropogenic-origin SOC, or important roles of anthropogenic pollutants for SOA formation, especially at urban areas, as strong correlations between water-soluble OC (an indicator of SOC) and anthropogenic pollutants, considerable amounts of fossil water-soluble OC, and significant contributions of fossil SOC (37-52% in summer months, 70-73% in winter months) are observed. Therefore, more studies are needed to reconcile the differences in the source attribution of SOC measurements.  相似文献   

20.
An intensive sampling of aerosol particles from ground level and 100 m was conducted during a strong pollution episode during the winter in Xi'an, China. Concentrations of water-soluble inorganic ions, carbonaceous compounds, and trace elements were determined to compare the composition of particulate matter (PM) at the two heights. PM mass concentrations were high at both stations: PM10 (PM with aerodynamic diameter < or =10 microm) exceeded the China National Air Quality Standard Class II value on three occasions, and PM2.5 (PM with aerodynamic diameter < or =2.5 microm) exceeded the daily U.S. National Ambient Air Quality Standard more than 10 times. The PM10 organic carbon (OC) and elemental carbon (EC) were slightly lower at the ground than at 100 m, both in terms of concentration and percentage of total mass, but OC and EC in PM2.5 exhibited the opposite pattern. Major ionic species, such as sulfate and nitrate, showed vertical variations similar to the carbonaceous aerosols. High sulfate concentrations indicated that coal combustion dominated the PM mass both at the ground and 100 m. Correlations between K+ and OC and EC at 100 m imply a strong influence from suburban biomass burning, whereas coal combustion and motor vehicle exhaust had a greater influence on the ground PM. Stable atmospheric conditions apparently led to the accumulation of PM, especially at 100 m, and these conditions contributed to the similarities in PM at the two elevations. Low coefficient of divergence (CD) values reflect the similarities in the composition of the aerosol between sites, but higher CDs for fine particles compared with coarse ones were consistent with the differences in emission sources between the ground and 100 m.  相似文献   