首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The quality of rural life can be affected by offensive odors released from animal buildings and storage units. The objectives of this study were to compare the concentrations of odor and odorants above different types of stirred swine slurry to analyze the relationships between concentrations of odor (and odorants) and physicochemical characteristics of the slurry (i.e. pH, temperature, dry matter, volatile solids, and concentration of 22 chemical compounds); and to propose predictive models for the odor concentration (OC) based on these physicochemical characteristics (solely and in combination with concentrations of specific odorants in the air above the slurries). The study comprised data on concentrations of odor and odorants in the air above slurry samples (fresh and/or stored) collected from production units with farrowing sows, finishing swines, or weaning pigs at eight swine operations (N = 48). OC measured in the air above stirred swine slurry samples were not significantly different among production types or storage times. The physicochemical characteristics of the slurries were not useful for predicting OC or concentrations of hydrogen sulfide (or organic sulfides) above the slurry, but were related to concentrations of other emitted gases such as phenols and indoles (r2 = 0.65–0.79, p <0.05), ammonia (r2 = 0.86, p < 0.05) and carboxylic acids (r2 = 0.23–0.59, p <0.05). There was good precision of predictive models of OC based on selected slurry characteristics (i.e. pH, dry matter, nitrogen content, sulfur content or concentrations of individual aromatic compounds and carboxylic acids) together with concentrations of specific odorants in the air (e.g. hydrogen sulfide) (r2 between 0.70 and 0.92). This study suggests that predictive models could be useful for evaluating odor nuisance potentials of swine slurry during handling.  相似文献   

2.
Biofilters are becoming an increasingly popular treatment device for odors and other volatiles found at wastewater treatment plants. A seashell media based biofilter was installed in April 2011 at Lake Wildwood Wastewater Treatment Plant located in Penn Valley, California. It was sampled seasonally to examine its ability to treat odorous compounds found in the air above the anaerobic equalization basin at the front end of the plant and to examine the properties of the biofilter and its recirculating water system. The odor profile method sensory panels found mainly sulfide odors (rotten eggs and rotten vegetable) and some fecal odors. This proved to be a useful guidance tool for selecting the required types of chemical sampling. The predominant odorous compounds found were hydrogen sulfide, methyl mercaptan and dimethyl sulfide. These compounds were effectively removed by the biofilter at greater than 99% removal efficiency therein reducing the chemical concentrations to below their odor thresholds. Aldehydes found in the biofilter were below odor thresholds but served as indicators of biological activity. Gas chromatography with mass spectrometry and gas chromatography with sensory detection showed the presence of dimethyl disulfide and dimethyl trisulfide as well, but barely above their respective odor thresholds. The neutrality of the pH of the recirculating water was variable depending on conditions in the biofilter, but a local neutral pH was found in the shells themselves. Other measurements of the recirculating water indicated that the majority of the bio-activity takes place in the first stage of the biofilter. All measurements performed suggest that this seashell biofilter is successful at removing odors found at Lake Wildwood. This study is an initial examination into the mechanism of the removal of odorous compounds in a seashell biofilter.

Implications:?This paper presents a thorough examination of a seashell media biofilter, a sustainable treatment technology used to remove reduced sulfide compounds. The durable performance of the seashell biofilter ensures that odors will be adequately controlled, preventing odor nuisance to surrounding residences, which is an emerging problem faced by waste management facilities. The odor profile method technique used in this study can be applied in many situations by waste management facilities and regulatory air management organizations for source tracking in relation to prevention and management of odor complaints, respectively.  相似文献   

3.
A pilot study was conducted to compare odor emissions from a windrow process and an aerated static pile and to determine the odor reduction efficiency of a pilot two-phase biofilter for odor control of biosolids composting. Chemical compounds identified as responsible for odors from biosolids composting include ammonia, dimethyl disulfide, carbon disulfide, formic acid, acetic acid, and sulfur dioxide (or carbonyl sulfide). Aeration was found to reduce the concentration of ammonia, formic acid, and acetic acid by 72, 57, and 11%, respectively, compared with a nearby windrow, while dimethyl sulfide, carbon disulfide, and sulfur dioxide (or carbonyl sulfide) concentrations were below detection limits. Using dilution-to-threshold olfactometry, aeration followed by biofiltration was found to reduce the odor from biosolids composting by 98%. Biofiltration also altered the character of odor emissions from biosolids composting, producing a less offensive odor with an earthy character. Biofiltration was found to reduce the concentration of ammonia, dimethyl disulfide, carbon disulfide, formic acid, acetic acid, and sulfur dioxide (or carbonyl sulfide) by 99, 90, 32, 100, 34, and 100%, respectively. The concentrations of those odorants were estimated to be 3700, 110000, 26,37,5, and 1.2 times reported human detection limits before the two-phase biofilter, respectively, and 42,9600,18,0,3, and 0 times human detection limits after the biofilter, respectively.  相似文献   

4.
It is a common practice in the midwestern United States to raise swine in buildings with under-floor slurry storage systems designed to store manure for up to one year. These so-called "deep-pit" systems are a concentrated source for the emissions of ammonia (NH3), hydrogen sulfide (H2S), and odors. As part of a larger six-state research effort (U.S. Department of Agriculture-Initiative for Future Agriculture and Food Systems Project, "Aerial Pollutant Emissions from Confined Animal Buildings"), realtime NH3 and H2S with incremental odor emission data were collected for two annual slurry removal events. For this study, two 1000-head deep-pit swine finishing facilities in central Iowa were monitored with one-year storage of slurry maintained in a 2.4 m-deep concrete pit (or holding tank) below the animal-occupied zone. Results show that the H2S emission, measured during four independent slurry removal events over two years, increased by an average of 61.9 times relative to the before-removal H2S emission levels. This increase persisted during the agitation process of the slurry that on average occurred over an 8-hr time period. At the conclusion of slurry agitation, the H2S emission decreased by an average of 10.4 times the before-removal emission level. NH3 emission during agitation increased by an average of 4.6 times the before-removal emission level and increased by an average of 1.5 times the before-removal emission level after slurry removal was completed. Odor emission increased by a factor of 3.4 times the before-removal odor emission level and decreased after the slurry-removal event by a factor of 5.6 times the before-removal emission level. The results indicate that maintaining an adequate barn ventilation rate regardless of animal comfort demand is essential to keeping gas levels inside the barn below hazardous levels.  相似文献   

5.
6.
7.
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.  相似文献   

8.
Gas chromatography–mass spectrometry, olfactometry, and other related methods were applied for the qualitative and quantitative analysis of the characteristics of odorous gases in the pretreatment workshop. The composition of odorous gases emitted from municipal food waste was also investigated in this study. The results showed that the tested gases are mainly composed of aromatic gases, which account for 49% of the total volatile organic compounds (VOC) concentrations. The nitrogenous compounds comprise 15% of the total concentration and the other gases comprise the remaining 36%. The level of odor concentration ranged from 2523 odor units (OU) m?3 to 3577 OU m?3. The variation of the total chemical composition ranged from 19,725 µg m?3 to 24,184 µg m?3. Among the selected four sampling points, the discharge outlet was detected to have the highest concentration in terms of odor, total chemical, sulfur compounds, and aromatics. The correlation analysis showed that the odor concentrations were evidently related to the total chemical composition, sulfur compounds, and aromatics (P < 0.05, n = 5). The odor activity value analysis identified the top three compounds, hydrogen sulfide (91.8), ethyl sulfide (35.8), and trimethylamine (70.6), which contribute to air pollution complaint of waste materials.

Implications: Currently, the amount of food waste has rapidly increased, which leads to difficulty in waste management and more odorous gases released as air pollution. In processing of food wastes by anaerobic fermentation, odorous gases are generated, which significantly affect the workers and occupants in the plant. In the pretreatment workshop for anaerobic decomposition, the odorous gases are generated because of the stacking and decomposition of food wastes. The gases emitted mainly consist of organic gases because the food wastes are mainly organic materials. The other odors that comprise 1% of the gases are S-compounds, aromatics, esters, alkanes, and limonene, which result in unpleasant odors that are harmful to the health.  相似文献   

9.
Livestock operations are associated with emissions of odor, gases, and particulate matter (PM). Livestock odor characterization is one of the most challenging analytical tasks. This is because odor-causing gases are often present at very low concentrations in a complex matrix of less important or irrelevant gases. The objective of this project was to develop a set of characteristic reference odors from a swine barn in Iowa and, in the process, identify compounds causing characteristic swine odor. Odor samples were collected using a novel sampling methodology consisting of clean steel plates exposed inside and around the swine barn for < or =1 week. Steel plates were then transported to the laboratory and stored in clean jars. Headspace solid-phase microextraction was used to extract characteristic odorants collected on the plates. All of the analyses were conducted on a gas chromatography-mass spectrometry-olfactometry system where the human nose is used as a detector simultaneously with chemical analysis via mass spectrometry. Multidimensional chromatography was used to isolate and identify chemicals with high-characteristic swine odor. The effects of sampling time, distance from a source, and the presence of PM on the abundance of specific gases, odor intensity, and odor character were tested. Steel plates were effectively able to collect key volatile compounds and odorants. The abundance of specific gases and odor was amplified when plates collected PM. The results of this research indicate that PM is major carrier of odor and several key swine odorants. Three odor panelists were consistent in identifying p-cresol as closely resembling characteristic swine odor, as well as attributing to p-cresol the largest odor response out of the samples. Further research is warranted to determine how the control of PM emissions from swine housing could affect odor emissions.  相似文献   

10.
Livestock operations are associated with emissions of odor, gases, and particulate matter. The majority of previous livestock odor studies focused on swine operations whereas relatively few relate to dairy cattle. Identifying the compounds responsible for the primary odor impact is a demanding analytical challenge because many critical odor components are frequently present at very low concentrations within a complex matrix of numerous insignificant volatiles. The objective of this study was to describe a chemical-sensory profile of dairy manure odor using headspace solid-phase microextraction (HS-SPME) and multidimensional gas chromatography-mass spectrometry-olfactometry (MDGC-MS-O). Two analytical approaches were used: (1) HS-SPME time-series extractions (from seconds up to 20 hr) followed by gas chromatography-mass spectrometry-olfactometry (GC-MS-O) analyses, and (2) relatively short HS-SPME extractions (30 min) followed by MDGC-MS-O analyses on selected chromatogram heart-cuts. Dairy manure was collected at research dairy farms in the United States and Israel. Volatile organic compounds (VOCs) resolved from multiple analyses included sulfur-containing compounds, volatile fatty acids, ketones, esters, and phenol/indole derivatives. A total of 86 potential odorants were identified. Of them, 17 compounds were detected by the human nose only. A greater number of VOCs and odorous compounds were detected, as well as higher mass loading, on solid-phase microextraction (SPME) fibers observed for longer extractions with SPME. However, besides sulfur-containing compounds, other selected compounds showed no apparent competition and displacement on the SPME fiber. The use of MDGC-MS-O increased chromatographic resolution even at relatively short extractions and revealed 22 additional odorants in one of the regions of the chromatogram. The two analytical approaches were found to be parallel to some extent whereas MDGC-MS-O can also be considered as a complementary approach by resolving more detailed chemical-sensory odor profiles.  相似文献   

11.
Setback distance has been used as an effective tool to avoid odor nuisance from livestock operations. Many setback distances were guidelines that were determined by empirical methods that are considered to be lack of science base. Air dispersion models have been used to determine setback distances; however, these models do not consider the short-time fluctuations of odor. A livestock odor dispersion model (LODM) was developed to consider the short-time variations of odor and predict occurrence frequency for certain levels of odor. In this study, this model was used to predict the occurrence frequency for various levels of odor in the vicinity (10 km) of a swine farm. Using selected odor criteria, setback distances between the swine farm and nearby communities were defined. Results indicate that the LODM can be used as an effective tool to determine setback distances.  相似文献   

12.
The effectiveness of 18 alternative technologies for reducing odor dispersion at and beyond the boundary of swine facilities was assessed in conjunction with an initiative sponsored through agreements between the Attorney General of North Carolina and Smithfield Foods, Premium Standard Farms, and Frontline Farmers. The trajectory and spatial distribution of odor emitted at each facility were modeled at 200 and 400 m downwind from each site under two meteorological conditions (daytime and nighttime) using a Eulerian-Lagrangian model. To predict the dispersion of odor downwind, the geographical area containing the odorant sources at each facility was partitioned into 10-m2 grids on the basis of satellite photographs and architectural drawings. Relative odorant concentrations were assigned to each grid point on the basis of intensity measurements made by the trained odor panel at each facility using a 9-point rating scale. The results of the modeling indicated that odor did not extend significantly beyond 400 m downwind of any of the test sites during the daytime when the layer of air above the earth's surface is usually turbulent. However, modeling indicated that odor from all full-scale farms extended beyond 400 m onto neighboring property in the evenings when deep surface cooling through long-wave radiation to space produces a stable (nocturnal) boundary layer. The results also indicated that swine housing, independent of waste management type, plays a significant role in odor downwind, as do odor sources of moderate to moderately high intensity that emanate from a large surface area such as a lagoon. Human odor assessments were utilized for modeling rather than instrument measurements of volatile organic compounds (VOCs), hydrogen sulfide, ammonia, or particulates less than 10 microm in diameter (PM10) because these physical measurements obtained simultaneously with human panel ratings were not found to accurately predict human odor intensity in the field.  相似文献   

13.
The effects of hydrogen sulfide (H2S) diffusion into activated sludge (AS) on odor and volatile organic compound (VOC) concentrations in offgas were studied over an 8-week period. Most VOCs detected in the offgas of both aeration tanks were aromatic hydrocarbons. The VOC concentrations generally decreased when H2S was introduced to the AS compared with the control, indicating a negative effect of H2S on VOC removal. Two volatile organic sulfur compounds present in the test AS offgas showed an increase followed by a decrease during H2S peak loads. Six VOCs and odor concentration increased during the introduction of an H2S peak; however no correlation was observed between H2S and odor concentration. The increase in odor concentration resulted from the increase in the concentration of six aromatic VOCs, which had their removal slowed down during a 100-ppmv H2S peak. Activated sludge diffusion provides effective H2S removal with minimal affect on odor emissions.  相似文献   

14.
To obtain annual odor emission profiles from intensive swine operations, odor concentrations and emission rates were measured monthly from swine nursery, farrowing, and gestation rooms for a year. Large annual variations in odor concentrations and emissions were found in all the rooms and the impact of the seasonal factor (month) was significant (P < 0.05). Odor concentration was low in summer when ventilation rate was high but high in winter when ventilation rate was low, ranging from 362 (farrowing room in July) to 8934 (nursery room in December) olfactory unit (OU) m(-3). This indicates that the air quality regarding odor was significantly better in summer than that in winter. Odor emission rate did not show obvious seasonal pattern as odor concentration did, ranging from 2 (gestation room in November) to 90 (nursery room in April) OU m(-2) sec(-1); this explains why the odor complaints for swine barns have occurred all year round. The annual geometric mean odor concentration and emission rate of the nursery room was significantly higher than the other rooms (P < 0.05). In order to obtain the representative annual emission rate, measurements have to be taken at least monthly, and then the geometric mean of the monthly values will represent the annual emission rate. Incorporating odor control technologies in the nursery area will be the most efficient in reducing odor emission from the farm considering its emission rate was 2 to 3 times of the other areas. The swine grower-finisher area was the major odor source contributing 53% of odor emission of the farm and should also be targeted for odor control. Relatively positive correlations between odor concentration and both H2S and CO2 concentrations (R(2) = 0.58) means that high level of these two gases might likely indicate high odor concentration in swine barns.  相似文献   

15.
This study characterized the seasonal concentration (C) and emission (E) patterns of odor, ammonia (NH3), and hydrogen sulfide (H2S) over the course of a whole year and their diurnal patterns in cold, warm, and mild seasons for a naturally ventilated free-stall dairy barn. It was found that seasonal odor and NH3 and H2S emissions varied greatly: from 17.2 to 84.4 odor units (OU) sec?1 AU?1 (AU: animal unit, 500 kg of animal body mass), from 0.27 to 0.92 mg sec?1 AU?1, and from 3 to 105 μg sec?1 AU?1, respectively. The overall concentrations of odor and NH3 were higher in the winter, whereas the emissions were higher in the mild and warm seasons. Diurnal variation was most significant for odor emission (OE) in the mild season when the ratio of maximum (279.2 OU sec?1 AU?1) to minimum value (60.5 OU sec?1 AU?1) was up to 4.6. The indoor air quality was also evaluated by considering not only the health effect of individual gases, but also the additive effect of NH3 and H2S. Results showed that the indoor air quality was poorest in cold seasons when NH3 C could exceed the threshold limit set out in occupational health regulation, and in fact could worsen due to the additive effect of the two gases. Further, it was suggested NH3 was a good indicator for predicting odor concentration (OC) or OE. The impact of climatic parameters on odor and gases were also examined, and it was found ventilation rate (VR) negatively affected OC and NH3 C, but positively impacted OE and NH3 E. Using 70% of the total data, a multilinear model for OE was developed as a function of VR and indoor relative humidity and was validated to be acceptable using the rest of the data.

Implications: Diurnal and seasonal variations of odor, NH3, and H2S concentrations and emissions were monitored for a naturally ventilated dairy barn in a cold region. The emission factors were calculated and indoor air quality was evaluated. The overall odor and NH3 concentrations were higher in winter, whereas emissions were higher in the mild and warm seasons. Diurnal variation was most significant for odor emission in the mild season, when the ratio of maximum to minimum value was up to 4.6. The results can be used to estimate odor and gas emissions from other dairy barns in Canada and other cold regions.  相似文献   

16.
A study of volatile organic sulfur emissions causing urban odors   总被引:2,自引:0,他引:2  
Muezzinoglu A 《Chemosphere》2003,51(4):245-252
Levels of hydrogen sulfide and sulfur containing organic compounds were studied in the air at the deltas of the polluted creeks in the city of Izmir, Turkey in summer 2001. High concentrations of these malodorous compounds were measured in the air samples. Presence of these compounds in the air was connected with the dark appearance and rising gas bubbles in the studied segments of the creeks. These creeks were like open sewers carrying wastewaters from the industry and residential areas into the inner Izmir Bay until September 2001.Within the scope of this study organic sulfur compounds such as methane thiol, ethane thiol, 2-propane thiol, 2-butane thiol, dimethylsulfide, dimethyldisulfide, thiophene, diphenylsulfide and hydrogen sulfide were studied in the air at selected urban sites where odor nuisance was recognized. Flux measurements from polluted surfaces were preferred rather than direct ambient air measurements. Organic sulfur emission fluxes from the creek surfaces were found above the values reported in the literature. Their concentrations and fluxes were higher in June field program. A limited number of measurements of reduced sulfur compound emission concentrations from the wastewater treatment plant equalization tank and the sludge drying beds as well as the landfill soil surface were also included in the study.Concentrations of total organic sulfur compounds and certain individual components such as dimethylsulfide and hydrogen sulfide in emitted gases from river surfaces were correlated with ambient SO(2) concentrations.  相似文献   

17.

Transfer station, incineration plant, and landfill site made up the major parts of municipal solid waste disposal system of S city in Eastern China. Characteristics of volatile compounds (VCs) and odor pollution of each facility were investigated from a systematic perspective. Also major index related to odor pollution, i.e., species and concentration of VCs, olfactory odor concentration, and theoretic odor concentration, was quantified. Oxygenated compounds and hydrocarbons were the most abundant VCs in the three facilities. Different chemical species were quantified, and the following average concentrations were obtained: transfer station, 54 VCs, 2472.47 μg/m3; incineration plant, 75 VCs, 33,129.25 μg/m3; and landfill site, 71 VCs, 1694.33 μg/m3. Furthermore, the average olfactory odor concentrations were 20,388.80; 50,677.50; and 4951.17, respectively. The highest odor nuisance was detected in the waste tipping port of the incineration plant. A positive correlation between the olfactory and chemical odor concentrations was found with R 2 = 0.918 (n = 15, P < 0.01). The result shows odor pollution risk transfer from landfill to incineration plant when adopting thermal technology to deal with the non-source-separated waste. Strong attention thus needs to be paid on the enclosed systems in incineration plant to avoid any accidental odor emission.

  相似文献   

18.
城市污水处理厂除臭生物滤池运行效果及影响因素研究   总被引:1,自引:0,他引:1  
对山东某城市污水处理厂散发的恶臭气体进行除臭研究,考察了除臭生物滤池的运行效果、工艺影响因素和除臭生物滤池内微生物相特点。结果表明:(1)在进气量为828 m3/h、气体停留时间为30 s、硫化氢和氨进气质量浓度分别为0.5~28.4、0.9~34.3 mg/m3的条件下,稳定运行时,大部分时间硫化氢和氨去除率分别达98%和80%以上,而且除臭生物滤池对于进气负荷具有较强的抗冲击能力。(2)当填料含湿量为43.6%~63.4%时,硫化氢去除率在90%以上;氨去除受填料含湿量的影响较大,填料含湿量越高越利于氨的去除。(3)在处理低浓度含硫化氢和氨的恶臭气体时,生物除臭工程可以在低填料pH(3.0左右)下长期运行,并保持较高的恶臭气体去除率。(4)运行第60天后,当温度为10℃以上时,硫化氢和氨去除率几乎不受影响;第169天后,当温度降至10℃以下时,硫化氢和氨去除率均有一定程度的下降,最低分别为94.6%和79.8%。(5)除臭生物滤池稳定运行时,优势硫氧化菌主要为嗜酸性硫细菌。  相似文献   

19.
20.
This study was conducted to determine both optimal settings applied to the plume dispersion model, AERMOD, and a scalable emission factor for accurately determining the spatial distribution of hydrogen sulfide concentrations in the vicinity of swine concentrated animal feeding operations (CAFOs). These operations emit hydrogen sulfide from both housing structures and waste lagoons. With ambient measurements made at 4 stations within 1 km of large swine CAFOs in Iowa, an inverse-modeling approach applied to AERMOD was used to determine hydrogen sulfide emission rates. CAFO buildings were treated as volume sources whereas nearby lagoons were modeled as area sources. The robust highest concentration (RHC), calculated for both measured and modeled concentrations, was used as the metric for adjusting the emission rate until the ratio of the two RHC levels was unity. Utilizing this approach, an average emission flux rate of 0.57 μg/m(2)-s was determined for swine CAFO lagoons. Using the average total animal weight (kg) of each CAFO, an average emission factor of 6.06 × 10(-7) μg/yr-m(2)-kg was calculated. From studies that measured either building or lagoon emission flux rates, building fluxes, on a floor area basis, were considered equal to lagoon flux rates. The emission factor was applied to all CAFOs surrounding the original 4 sites and surrounding an additional 6 sites in Iowa, producing an average modeled-to-measured RHC ratio of 1.24. When the emission factor was applied to AERMOD to simulate the spatial distribution of hydrogen sulfide around a hypothetical large swine CAFO (1M kg), concentrations 0.5 km from the CAFO were 35 ppb and dropped to 2 ppb within 6 km of the CAFO. These values compare to a level of 30 ppb that has been determined by the State of Iowa as a threshold level for ambient hydrogen sulfide levels.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏