首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
The objective of this study is to investigate the air ventilation impacts of the so called “wall effect” caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD – FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0° and 22.5°) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio (VR) and the retention time (Tr) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a “wall” upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning.  相似文献   

2.
Lu WZ  Wang XK 《Chemosphere》2008,71(3):561-567
As the addressing of high demand of good air quality in urban area, a study on air pollutant dispersion and distribution resulting from vehicular exhaust emission is strongly required. In particular, vehicular exhaust emission has become a major air pollution source in metropolitan city like Hong Kong, which is characterized with the heavy, dense traffic flow and the limited land resources. Respirable suspended particulate (RSP) is one of main pollutants resulted from vehicular exhaust emission in urban area. Hence, in this study, we focus on analyzing the variation of RSP levels including diurnal, monthly and annual patterns at selected roadsides in Hong Kong during the period of 1998--2005. Furthermore, the relationships between RSP level and the relevant meteorological factors such as temperature, rainfall and wind conditions in Hong Kong territory have been discussed as well.  相似文献   

3.
PM2.5 samples were collected at five sites in Guangzhou and Hong Kong, Pearl River Delta Region (PRDR), China in both summer and winter during 2004–2005. Elemental carbon (EC) and organic carbon (OC) in these samples were measured. The OC and EC concentrations ranked in the order of urban Guangzhou > urban Hong Kong > background Hong Kong. Total carbonaceous aerosol (TCA) contributed less to PM2.5 in urban Guangzhou (32–35%) than that in urban Hong Kong (43–57%). The reason may be that, as an major industrial city in South China, Guangzhou would receive large amount of inorganic aerosol from all kinds of industries, however, as a trade center and seaport, urban Hong Kong would mainly receive organic aerosol and EC from container vessels and heavy-duty diesel trucks. At Hong Kong background site Hok Tsui, relatively lower contribution of TCA to PM2.5 may result from contributions of marine inorganic aerosol and inland China pollutant. Strong correlation (R2=0.76–0.83) between OC and EC indicates minor fluctuation of emission and the secondary organic aerosol (SOA) formation in urban Guangzhou. Weak correlation between OC and EC in Hong Kong can be related to the impact of the long-range transported aerosol from inland China. Averagely, secondary OC (SOC) concentrations were 3.8–5.9 and 10.2–12.8 μg m−3, respectively, accounting for 21–32% and 36–42% of OC in summer and winter in Guangzhou. The average values of 4.2–6.8% for SOA/ PM2.5 indicate that SOA was minor component in PM2.5 in Guangzhou.  相似文献   

4.
Due to the complexity of the underlying surface, urban boundary layers may exhibit very different wind-temperature field structures compared with rural areas. In this study, an urban boundary layer model with a resolution of 500 m is applied to Hong Kong, a place characterized by complex topography with high mountains and dense urban developments. Five surface land use types are considered; grass and shrub land, trees, water, old urban areas and new town developments. The urban boundary layer model is embedded into the National Center for Atmospheric Research (NCAR) Mesoscale Model, version 5 (MM5). The initial and boundary conditions are obtained from the National Centers for Environmental Prediction (NCEP)/NCAR reanalysis dataset. The modeling approach therefore takes into account both the mesoscale background field and the urban underlying surface. The model is applied to the simulation of a pollution episode in Hong Kong. Results show good agreement with meteorological data for the surface winds and temperature. The model successfully simulates the urban heat island and the occurrence of a sea–land breeze circulation, and their impact on air pollutant transport and dispersion.  相似文献   

5.
Polycyclic aromatic hydrocarbons (PAHs) and carbonyls compounds are becoming a major component of atmospheric toxic air pollutants (TAPs) in Hong Kong. Many studies in Hong Kong show that traffic emission is one of the most significant contributors in urban area of Hong Kong. A twelve months monitoring program for PAHs and carbonyl compounds started on 10 April 1999 including a two weeks intensive sampling in winter had been performed at a roadside urban station at Hong Kong Polytechnic University in order to determine the monthly and seasonal variations of PAHs and carbonyl concentrations. The objective of this study is to characterize the roadside concentrations of selected TAPs (PAHs and carbonyl compounds) and to compare with the long-term compliance monitoring data acquired by Hong Kong Environmental Protection Department (EPD). Monthly variations, seasonal variations and winter/summer ratios at the monitoring station are discussed.  相似文献   

6.

Introduction  

Levoglucosan and carbonaceous species in the background aerosol of coastal southeast China were measured at Jianfengling (JFL), a background mountain site in a National Reserve Park on Hainan Island, and at Hok Tsui (HT), a rural site on the southern coast of Hong Kong from April to May of 2004 during an intensive field study.  相似文献   

7.
This paper is a contribution to the understanding of the topoclimatic and environmental geography of the basin where Santiago — one of the most polluted Latin American city – is located. In the first part, land-use change is analysed looking at the climatic transformation caused by the rapid transit from natural semiarid surface to urban areas. In the second part, seasonal weather and daily cycles of slope winds and the available ventilation are described trying to relate those patterns with the spatial distribution of air pollution. A combination of meteorological, geographical and cultural factors explain extreme air pollution events: meteorologically, Santiago is under permanent subsidence inversion layers. Geographically, the city is located in a closed basin surrounded by mountains. Culturally, the urban area has the highest population concentration (40% of the national total), industries (near 70% of the total) and vehicles, which are the main sources of smog. The urban and suburban transport system is based on a large number of buses (diesel) and private cars, both experiencing a rapid growth from the past few years. The city and specially the transport system generates high emissions of pollutant, but the natural semiarid deforested soils and slopes are also important sources. The local wind system can explain the differential spatial distribution on the concentration of air pollutants in the city and its periphery. In winter (rain season) concentrations of particulate matter are higher at the centre and the SW part of the city. The andean piedmont area (E part of the city) shows minimum values, suggesting major ventilation effects of slope and valley winds. Ozone exceeds air quality standards in summer (dry season) at all sites in the centre and periphery. However, the O3-concentrations are higher on preferred residential areas located at the piedmont area (E part of the city), suggesting air pollution transport effects. Currently, there is no consideration of these local climatic features in the process of urban planning.  相似文献   

8.
Ozone measurements made from 5 sites in Hong Kong have been analyzed, including those from one upwind, one downwind, and three urban locales. The data are analyzed in terms of the seasonal and diurnal trends. A subset of data in autumn is further analyzed to study the relationship between the ozone spatial pattern and wind flow as well as other meteorological parameters. The results show that averaged ozone levels at most sites exhibit maxima in autumn, which appears to be a unique feature for eastern Asia. On average the daily maximum 1-h concentrations are found to be higher in the western (normally downwind) site than those on the eastern side and in urban areas. Examination of surface wind patterns and other meteorological parameters suggest that elevated ozone concentrations on the western side occur during the days with intense solar radiation, light winds, and in the presence of a unique wind circulation. The wind reversal in the western parts under the “convergence” flow is believed to be an important cause of the high-ozone events observed there. Such wind flow may re-circulate/transport nearby urban plumes (in this case the Hong Kong–Shenzhen urban complex). Examination of chemical data from the western site has shown that averaged afternoon SO2 to NOx ratios on days with wind reversal are larger than those of typical urban Hong Kong and that a significant SO2 enhancement was clearly indicated on several occasions. The SO2 enhancement may be interpreted as being the evidence to suggest the contribution of regional sources and/or Hong Kong’s power plants (both containing high SO2). A case study has shown that when moderately strong northwesterly wind prevails, elevated ozone and SO2 can be transported to western Hong Kong from the inner Pearl Delta region. This study has also indicated that under the impact of ENE winds the eastern side of Hong Kong is not frequently affected by the re-circulating ozone plumes present in the western side.  相似文献   

9.
The intake fraction (iF) of nonreactive constituents of exhaust from mobile vehicles in the urban area of Hong Kong is investigated using available monitoring data for carbon monoxide (CO) as a tracer of opportunity. Correcting for regional transport of carbon monoxide into Hong Kong, the annual-average iF for nonreactive motor vehicle emissions within the city is estimated to be around 270 per million. This estimated iF is much higher than values previously reported for vehicle emissions in US urban areas, Helsinki and Beijing, and somewhat lower than those reported for a densely populated street canyon in downtown Manhattan, New York City, or for emissions into indoor environments. The reported differences in intake fractions in various cities mainly result from the differences in local population densities. Our analysis highlights the importance of accounting for the influence of upwind transport of pollutants when using ambient data to estimate iF for an urban area. For vehicle exhaust in Hong Kong, it is found that the in/near vehicle microenvironment contributes similarly to the indoor home environment when accounting for the overall iF for children and adults.  相似文献   

10.
The paper presents the results of the development of a standard driving cycle in the urban areas of Hong Kong. On-road speed–time data were collected by an instrumented diesel vehicle along two fixed routes located in two urban districts in Hong Kong. The collected data were analyzed and compared with mandatory driving cycles used elsewhere. It was found that none of these mandatory cycles could satisfactorily describe the driving characteristics in Hong Kong. A unique driving cycle was therefore developed for Hong Kong. The cycle was built up by extracting parts of the on-road speed data such that the summary statistics of the sample are close to that derived from the data population of the test runs.  相似文献   

11.
Indoor and outdoor air quality investigation at schools in Hong Kong   总被引:7,自引:0,他引:7  
Lee SC  Chang M 《Chemosphere》2000,41(1-2):109-113
Five classrooms in Hong Kong (HK), air-conditioned or ceiling fans ventilated, were chosen for investigation of indoor and outdoor air quality. Parameters such as temperature, relative humidity (RH), carbon dioxide (CO2), sulphur dioxide (SO2), nitric oxide (NO), nitrogen dioxide (NO2), respirable particulate matter (PM10), formaldehyde (HCHO), and total bacteria counts were monitored indoors and outdoors simultaneously. The average respirable particulate matter concentrations were higher than the HK Objective, and the maximum indoor PM10 level exceeded 1000 microg/m3. Indoor CO2 concentrations often exceeded 1000 microl/l in air-conditioning and ceiling fan classrooms, indicating inadequate ventilation. Maximum indoor CO2 level reached 5900 microl/l during class at the classroom with cooling tower ventilation. Increasing the rate of ventilation or implementation of breaks between classes is recommended to alleviate the high CO2 level. Other pollution parameters measured in this study complied with the standards. The two most important classroom air quality problems in Hong Kong were PM10 and CO2 levels.  相似文献   

12.
Volatile organic compounds (VOCs) in urban atmosphere of Hong Kong   总被引:21,自引:0,他引:21  
Lee SC  Chiu MY  Ho KF  Zou SC  Wang X 《Chemosphere》2002,48(3):375-382
The assessment of volatile organic compounds (VOCs) has become a major issue of air quality network monitoring in Hong Kong. This study is aimed to identify, quantify and characterize volatile organic compounds (VOCs) in different urban areas in Hong Kong. The spatial distribution, temporal variation as well as correlations of VOCs at five roadside sampling sites were discussed. Twelve VOCs were routinely detected in urban areas (Mong Kok, Kwai Chung, Yuen Long and Causeway Bay). The concentrations of VOCs ranged from undetectable to 1396 microg/m3. Among all of the VOC species, toluene has the highest concentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the major constituents (more than 60% in composition of total VOC detected), mainly contributed from mobile sources. Similar to other Asian cities, the VOC levels measured in urban areas in Hong Kong were affected both by automobile exhaust and industrial emissions. High toluene to benzene ratios (average T/B ratio = 5) was also found in Hong Kong as in other Asian cities. In general, VOC concentrations in the winter were higher than those measured in the summer (winter to summer ratio > 1). As toluene and benzene were the major pollutants from vehicle exhausts, there is a necessity to tighten automobile emission standards in Hong Kong.  相似文献   

13.
More than half of the world's population lives in cities, and their populations are rapidly increasing. Information on vertical and diurnal characterizations of volatile organic compounds (VOCs) in urban areas with heavy ambient air pollution can help further understand the impact of ambient VOCs on the local urban environment. This study characterized vertical and diurnal variations in VOCs at 2, 13, 32, 58, and 111 m during four daily time periods (7:00 to 9:00 a.m., 12:00 to 2:00 p.m., 5:00 to 7:00 p.m., and 11:00 p.m. to 1:00 a.m.) at the upwind of a high-rise building in downtown, Kaohsiung City, Taiwan. The study used gas chromatography-mass spectrometry to analyze air samples collected by silica-coated canisters. The vertical distributions of ambient VOC profiles showed that VOCs tended to decrease at greater heights. However, VOC levels were found to be higher at 13 m than at ground level at midnight from 11:00 p.m. to 1:00 a.m. and higher at 32 than 13 m between 7:00 and 9:00 a.m. These observations suggest that vertical dispersion and dilution of airborne pollutants could be jointly affected by local meteorological conditions and the proximity of pollution sources. The maximum concentration of VOCs was recorded during the morning rush hours from 7:00 to 9:00 a.m., followed by rush hours from 5:00 to 7:00 p.m., hours from 12:00 to 2:00 p.m., and hours from 11:00 p.m. to 1:00 a.m., indicating that the most VOC compounds in urban air originate from traffic and transportation emissions. The benzene-toluene-ethyl benzene-xylene (BTEX) source analysis shows that BTEX at all heights were mostly associated with vehicle transportation activities on the ground.  相似文献   

14.
Hong Kong is a densely populated city situated in the fast developing Pearl River Delta of southern China. In this study, the recent data on ozone (O3) and related air pollutants obtained at three sites in Hong Kong are analyzed to show the variations of O3 in urban, sub-urban and rural areas and the possible regional influences. Highest monthly averaged O3 was found at a northeastern rural site and lowest O3 level was observed at an urban site. The levels of NOx, CO, SO2 and PM10 showed a different spatial pattern with the highest level in the urban site and lowest at the rural site. Analysis of chemical species ratios such as SO2/NOx and CO/NOx indicated that the sites were under the influences of local and regional emissions to varying extents reflecting the characteristics of emission sources surround the respective sites. Seasonal pattern of O3 is examined. Low O3 level was found in summer and elevated levels occurred in autumn and spring. The latter appears different from the previous result obtained in 1996 indicating a single maximum occurring in autumn. Principal component analysis was used to further elucidate the relationships of air pollutants at each site. As expected, the O3 variation in the northeastern rural area was largely determined by regional chemical and transport processes, while the O3 variability at the southwestern suburban and urban sites were more influenced by local emissions. Despite the large difference in O3 levels across the sites, total potential ozone (O3+NO2) showed little variability. Cases of high O3 episodes were presented and elevated O3 levels were formed under the influence of tropical cyclone bringing in conditions of intense sunlight, high temperature and light winds. Elevated O3 levels were also found to correlate with enhanced ratio of SO2 to NOx, suggesting influence of regional emissions from the adjacent Pearl River Delta region.  相似文献   

15.
Hong Kong's persistent unhealthy level of fine particulate matter is a current public health challenge, complicated by the city being located in the rapidly industrializing Pearl River Delta Region of China. While the sources of the region's fine particulate matter (PM2.5) are still not well understood, this study provides new source information through ground measurements and statistical analysis of 24 elements associated with particulate matter collected on filters. Field measurements took place over 4 months (October 2002, December 2002, March 2003, and June 2003) at seven sites throughout the Pearl River Delta, with three sites located in Hong Kong and four sites in the neighboring province, Guangdong. The 4-month average element concentrations show significant variation throughout the region, with higher levels of nearly every species seen among the northern Guangdong sites in comparison to Hong Kong. The high correlation (Pearson r>0.8) and similar magnitudes of 11 species (Al, Si, S, K, Ca, Mn, Fe, Zn, Br, Rb, and Pb) at three contrasting sites in Hong Kong indicate that sources external to Hong Kong dominate the regional levels of these elements. Further correlative analysis compared Hong Kong against potential source areas in Guangdong Province (Shenzhen, Zhongshan, and Guangzhou). Moderate correlation of sulfur for all pairings of Hong Kong sites with three Guangdong sites in developed areas (average Pearson r of 0.52–0.94) supports the importance of long-distance transport impacting the region as a whole, although local sources also clearly impact observed concentrations. Varying correlative characteristics for zinc when Hong Kong sites are paired with Shenzhen (average r=0.86), Guangzhou (average r=−0.65) and Zhongshan (average r=0.45) points to a source area located south of Guangzhou and locally impacting Zhongshan. The concentration distribution and correlative characteristics of bromide point to sources located within the Pearl River Delta, but the specific location is yet inconclusive. Uniquely poor correlation of eight species (Al, Si, K, Ca, Mn, Fe, Rb, and Pb) for the pairing of Hong Kong sites with Guangzhou, in addition to the relatively higher concentrations measured at Guangzhou, indicates a significant regional impact due to land development and industrial activities in the Guangzhou vicinity.  相似文献   

16.
With recent improvements to living standards and renovations to many residential buildings, a large volume of new building materials have been utilized throughout China. Formaldehyde and other kinds of VOC pollutants, such as benzene, toluene and xylene found in new building materials, however, emit gases that may lead to some direct or potential health problems. Bake-out with dilution ventilation technology has the potential to shorten emission cycles of indoor air pollution, by which off-gassing from building materials can be reduced. In this paper, a test chamber was used to represent a newly renovated residential room in China. Experiments were conducted to study the applicability of the technology for removing of formaldehyde, benzene, toluene and xylene. A numerical method was used to simulate a 1 m3-chamber-TVOC removing amount under different operating conditions and the concentration change of TVOC during the bake-out exhaust dilution process. The effects of bake-out temperatures and times, ventilation times, and air change rates on removal are also discussed.

Implications: VOCs are the main study objective in this paper. With higher baking temperature, longer baking time and longer ventilation time, the removal efficiency is higher in experiment. Removal content of TVOC increases with the increasing number of ACH. With the consideration of energy consumption, it is more reasonable to choose a ventilation time of 4 hours if ACH is 1.2 times/h.  相似文献   


17.
Rapid urbanization and industrialization in South China has placed great strain on the environment and on human health. In the present study, the total suspended particulate matter (TSP) in the urban and suburban areas of Hong Kong and Guangzhou, the two largest urban centres in South China, was sampled from December 2003 to January 2005. The samples were analysed for the concentrations of major elements (Al, Fe, Mg and Mn) and trace metals (Cd, Cr, Cu, Pb, V and Zn), and for Pb isotopic composition. Elevated concentrations of metals, especially Cd, Pb, V and Zn, were observed in the urban and suburban areas of Guangzhou, showing significant atmospheric trace element pollution. Distinct seasonal patterns were observed in the heavy metal concentrations of aerosols in Hong Kong, with higher metal concentrations during the winter monsoon period, and lower concentrations during summertime. The seasonal variations in the metal concentrations of the aerosols in Guangzhou were less distinct, suggesting the dominance of local sources of pollution around the city. The Pb isotopic composition in the aerosols of Hong Kong had higher 206Pb/207Pb and 208Pb/207Pb ratios in winter, showing the influence of Pb from the northern inland areas of China and the Pearl River Delta (PRD) region, and lower 206Pb/207Pb and 208Pb/207Pb ratios in summer, indicating the influence of Pb from the South Asian region and from marine sources. The back trajectory analysis showed that the enrichment of heavy metals in Hong Kong and Guangzhou was closely associated with the air mass from the north and northeast that originated from northern China, reflecting the long-range transport of heavy metal contaminants from the northern inland areas of China to the South China coast.  相似文献   

18.
Comparison of PM2.5 carbon measurement methods in Hong Kong, China   总被引:1,自引:0,他引:1  
Samples from Hong Kong, China, were analyzed for organic carbon (OC), elemental carbon (EC), and total carbon (TC) by three thermal protocols (low-temperature IMPROVE and high-temperature STN and NIOSH) and two optical monitoring methods: reflectance and transmittance. Good agreement (+/-10%) for TC among the three protocols was observed for sample loadings of 1-55 microg m(-3). The two protocols using a reflectance pyrolysis correction showed best agreement for EC, with <20% differences found for approximately 80% of the samples. Hong Kong has a large diesel fleet, and for some heavily loaded samples the light transmittance was too low for quantitative detection, resulting in large uncertainties in the OC/EC split based on transmittance. Hong Kong experienced OC levels similar to those at US sites, but has much higher EC concentrations. OC/EC ratios range from 2 to 5 at two US sites and from 0.2 to 1.2 at three Hong Kong sites.  相似文献   

19.
Ho KC  Chow YL  Yau JT 《Chemosphere》2003,52(9):1441-1450
Currently, about 80% of drinking water in Hong Kong is abstracted from The East River (Dongjiang) that is located in the mainland side of China. Literature records and monitoring results of 2000-2001 confirmed that the lower section of the Dongjiang had been contaminated by organic and inorganic pollutants. Statistical analyses showed that the increases of total cadmium, copper and zinc in the surface layer of sediment of Hong Kong reservoirs from 1994 to 2001 were positively correlated (significant at p<0.05) with those in the surface layer of sediments of the lower Dongjiang. Recent microbiological survey revealed that pathogens such as Salmonella spp., Vibro spp., Giardia lamblia and Cryptosporidium parvum appeared occasionally in water samples of the Dongjiang and Hong Kong reservoirs. While analytical results found that currently most of the heavy metals, trace organics and microbes were removed by the drinking water treatment plants in Hong Kong, the long-term health risk of drinking water contamination should not be overlooked. The Water Supplies Department of Hong Kong is recommended to intensify its water quality monitoring program to cover pathogenic bacteria and parasites in watercourses and reservoirs.  相似文献   

20.
This study assessed the effect of temperature and thermal atmospheric conditions on all-cause and cardiovascular mortality in Bangladesh. In particular, differences in the response to elevated temperatures between urban and rural areas were investigated. Generalized additive models (GAMs) for daily death counts, adjusted for trend, season, day of the month and age were separately fitted for urban and rural areas. Breakpoint models were applied for determining the increase in mortality above and below a threshold (equivalent) temperature. Generally, a 'V'-shaped (equivalent) temperature-mortality curve with increasing mortality at low and high temperatures was observed. Particularly, urban areas suffered from heat-related mortality with a steep increase above a specific threshold. This adverse heat effect may well increase with ongoing urbanization and the intensification of the urban heat island due to the densification of building structures. Moreover, rising temperatures due to climate change could aggravate thermal stress.  相似文献   