首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
ABSTRACT. This work evaluates the economic losses due to diversion from the Snake River during the relatively low-flow year May 1928-April 1929. The results determine the losses due to pollution abatement and power generation for several different patterns and volumes of diversion, and the tool of analysis is dynamic programming.  相似文献   

2.
Emissions from electricity generation will have to be reduced to near-zero to meet targets for reducing overall greenhouse gas emissions. Variable renewable energy sources such as wind will help to achieve this goal but they will have to be used in conjunction with other flexible power plants with low-CO2 emissions. A process which would be well suited to this role would be coal gasification hydrogen production with CCS, underground buffer storage of hydrogen and independent gas turbine power generation. The gasification hydrogen production and CO2 capture and storage equipment could operate at full load and only the power plants would need to operate flexibly and at low load, which would result in substantial practical and economic advantages. This paper analyses the performances and costs of such plants in scenarios with various amounts of wind generation, based on data for power demand and wind energy variability in the UK. In a scenario with 35% wind generation, overall emissions of CO2 could be reduced by 98–99%. The cost of abating CO2 emissions from the non-wind residual generation using the technique proposed in this paper would be less than 40% of the cost of using coal-fired power plants with integrated CCS.  相似文献   

3.
岷江都江堰段水环境容量计算及水质综合评价   总被引:3,自引:0,他引:3  
梁荫 《四川环境》1996,15(2):58-63
岷江水域兼有灌溉,供水,发电等多重功能。本文对岷江都江堰段水环境现状进行了模糊综合评价,并计算了水环境容量。  相似文献   

4.
Abstract

Design and prototyping of a standalone photovoltaic power generation system using the Virtual Test Bed software environment is presented. The design includes establishing physics-based models for components, prototyping system architectures, implementing control algorithms, testing and evaluating the system performance using the actual weather data at a particular geographical location. The dynamic performance of the photovoltaic power system and its components are revealed in great details through the system level simulation. This knowledge is used for verification and improvements of the system design in order to achieve the best system power capability, efficiency and size.  相似文献   

5.
To improve the competiveness in the energy market, it is necessary that the wind power plants provide guaranteed power generation, although, it is not possible to forecast power availability from wind power plant accurately. This paper presents a stochastic model and solution technique for the combined operation of wind and pumped storage power plants to improve the power availability and increasing the profit considering uncertainties of wind power generation. In this model, uncertainties in wind data have been forecasted for grid connected day-ahead market using Weibull distribution model. The imbalances in the forecasted wind data and the market demand have been reduced by operating the pumped storage power plant. In this stochastic mixed integer problem, pumped storage plant can take the supply either from the grid or from the wind power plant for the pumping operation to store the energy in order to utilize this energy during peak hours for increasing the overall revenue. The reliability of the pumped storage is improved by replacing the conventional unit with the adjustable speed type pumped storage unit. In order to prove the optimality of the solution, two case studies were considered. In case studyI, scheduling is provided by operating the conventional pumped storage unit, whereas in case studyII, adjustable speed pumped storage unit has been used. It has been found that the adjustable speed pumped storage unit has further reduced the imbalance between generated power and demand. The complete approach has been formulated and implemented using AMPL software.  相似文献   

6.
随着四大热电中心的建成投产,北京市完成了由燃机替代煤机的转变,实现了更加智能化的清洁能源发电供热。2013年北京市碳市场启动运行,给刚起步的燃气供热机组运行赋予了更广阔和更深远的意义;2017年12月19日,以发电行业为突破口,全国碳排放交易体系正式启动,北京市热电行业低碳运行管理意义重大而深远。本文以燃气热电联产机组运行数据为基础,通过计算分析,提出燃气热电联产机组清洁、高效、低碳运行方式,为全国碳市场启动后,北京乃至全国热电行业低碳运行管理提供经验借鉴。  相似文献   

7.
Abstract: Thermoelectric power generation is responsible for the largest annual volume of water withdrawals in the United States although it is only a distant third after irrigation and industrial sectors in consumptive use. The substantial water withdrawals by thermoelectric power plants can have significant impacts on local surface and ground water sources, especially in arid regions. However, there are few studies of the determinants of water use in thermoelectric generation. Analysis of thermoelectric water use data in existing steam thermoelectric power plants shows that there is wide variability in unitary thermoelectric water use (in cubic decimeters per 1 kWh) within and among different types of cooling systems. Multiple‐regression models of unit thermoelectric water use were developed to identify significant determinants of unit thermoelectric water use. The high variability of unit usage rates indicates that there is a significant potential for water conservation in existing thermoelectric power plants.  相似文献   

8.
ABSTRACT: The methodology underlying, and the estimates incorporated in the Corps of Engineers' economic evaluation of the Arkansas River Basin Chloride Control Project are evaluated and judged deficient in several ways. An improperly specified alternative cost analysis probably results in overestimates of the total regional demand for water, the demand for Arkansas River Water, and the cost-savings realized with the project in place. The quantitative effect of these errors is not determined. However, other adjustments are identified which are evaluated using the Corps' data. These adjustments reduce B/C from 2.64 to 0.57; principally as a result of corrections for over-estimates of cost-savings in steam-electric generation, and for use of improper discounting procedures and gross output-earnings ratios.  相似文献   

9.
10.
We performed a quantitative assessment of the impact of impingement at power plants on the Hudson River white perch population We estimated that impingement reduces the abundance of each white perch year class by at least 10% and probably by 15–20% or more after 2–3 years of vulnerability to power plants We attempted to detect effects of impingement on average year-class abundance of white perch from a time series of abundance indices derived from impingement data We found, however, that neither impingement collection rates observed at Hudson River power plants nor beach seine data provide a reliable index of year-class strength in white perch. Even if a reliable index were developed, natural fluctuations in year-class strength are great enough that a short-term monitoring program would be inadequate for detecting even a large reduction in average year-class strength. We performed a multipopulation analysis using simple food chain and food web models The results suggest that any long-term decline in white perch abundance caused by impingement should be accompanied by an increase in the abundance of one or more competing fish species and by an increase in the biomass of adult white perch relative to young-of-the-year.We conclude that 1) at present, assessments of population-level impact of impingement should focus on short-term effects, 2) research is needed to develop a reliable index of year-class strength for use in long-term monitoring programs, 3) identification and quantification of natural environmental factors influencing year-class strength are needed to improve our ability to predict and detect changes in abundance, and 4) it would be useful in designing monitoring programs to focus on detecting patterns of change among populations and age groups rather than solely on declines in abundance of individual populationsResearch sponsored by the Office of Nuclear Regulatory Research, US Nuclear Regulatory Commission under Interagency Agreement No. 40-550-75 with the US Department of Energy under Contract W-7405-eng-26 with Union Carbide Corporation. Publication No. 2030, Environmental Sciences Division, ORNL.  相似文献   

11.
Using meteorological and electricity demand data for a 4-year period, electricity demand in Shetland was modeled to provide an estimate of the demand over a 30-year period from 1 January 1981. That modeled demand was then compared to estimated wind power output over the same period using the WAsP model. The wind farm output was estimated for a range of sizes of wind farm up to the consented 370 MW Viking Wind Farm in Shetland. Some wind power was available for 94% of the time and the 370 MW wind farm would meet 100% of demand for nearly 80% of the time. The statistics of single and accumulated deficits were calculated for a range of wind farms and estimates of the amount of additional generation capacity and additional power requirements were assessed. The study suggests that with storage, wind power in Shetland could meet all electricity demand in Shetland at around £130 to £150/MWh (excluding subsidy) and with a grid connection allowing the sale of excess power, those costs could be reduced.  相似文献   

12.
ABSTRACT: The optimization of real-time operations for a single reservoir system is studied. The objective is to maximize the sum of hourly power generation over a period of one day subject to constraints of hourly power schedules, daily flow requirement for water supply and other purposes, and the limitations of the facilities. The problem has a nonlinear concave objective function with nonlinear concave and linear constraints. Nonlinear Duality Theorems and Lagrangian Procedures are applied to solve the problem where the minimization of the Lagrangian is carried out by a modified gradient projection technique along with an optimal stepsize determination routine. The dimension of the problem in terms of the number of variables and constraints is reduced by eliminating the 24 continuity equations with a special implicit routine. A numerical example is presented using data provided by the Bureau of Reclamation, Sacramento, California.  相似文献   

13.
2020年9月22日,习近平主席在第七十五届联合国大会上郑重承诺,中国将提高自主贡献力度,采取更加有力的政策和措施,努力争取2060年前实现碳中和。电力部门是我国能源系统实现碳中和的关键,而生物质能源技术在电力部门的部署对于推动实现碳中和具有不可替代的重要意义。本文针对三类生物质能源的发电技术,包括生物质直燃/气化发电、生物质耦合发电、生物质与碳捕获封存技术联合发电,分析了技术的国内外发展现状,并从技术可行性、资源可行性、经济可行性和环境影响等方面评析了其在推动电力部门低碳转型过程中的可行性。同时,结合碳中和愿景下电力部门的减排要求及对相关技术潜力的最新研判,对生物质能源技术在我国电力部门的部署提出了相应的政策建议。  相似文献   

14.
阐述了垃圾焚烧发电的公共利益性质,政府支持垃圾焚烧发电是增进公共利益的必然要求,政府应构建支持垃圾焚烧发电常态机制,整合与垃圾焚烧发电相关各方力量,制定科学合理的正负激励政策,以期相关各方为垃圾焚烧发电的贡献最大化,有效增进公共利益。  相似文献   

15.
This paper aims at analyzing the feasibility of a waste heat recovery power generation plant based on parametric optimization and performance analysis using different organic Rankine cycle configurations and heat source temperature conditions with working fluid R-12, R-123, R-134a, and R-717. A parametric optimization of turbine inlet temperature(TIT) was performed to obtain the irreversibility rate, system efficiency, availability ratio, turbine work output, system mass flow rate, second-law efficiency, and turbine outlet quality, along the saturated vapor line and also on superheating at an inlet pressure of 2.50 MP in basic as well as regenerative organic Rankine cycle. The calculated results reveal that selection of a basic organic Rankine cycle using R-123 as working fluid gives the maximum system efficiency, turbine work output, second-law efficiency, availability ratio with minimum system irreversibility rate and system mass flow rate up to a TIT of 150°C and appears to be a choice system for generation of power by utilizing the flue gas waste heat of thermal power plants and above 150°C the regenerative superheat organic Rankine cycle configuration using R 123 as working fluid gives the same results.  相似文献   

16.
综述了我国袋式除尘高温滤料在燃煤发电、垃圾焚烧发电、水泥工业等工业领域的应用现状以及高温除尘滤料未来的发展趋势。  相似文献   

17.
This article focused on the performance of oil palm kernel shell (PKS) gasification using a medium-scale downdraft gasifier with a feedstock capacity of 500 kg at a temperature range of 399–700°C and at a feed rate of 177 kg/h. This article is important for evaluating the reliability of PKS gasification for commercial power generation activities from biomass. The process performance was evaluated based on the syngas calorific value (CV), syngas flow rate, and its cold gas efficiency (CGE). The syngas flow rates and CVs were measured using a gas flow meter and a gas analyzer in real time. The data obtained were then analyzed to evaluate the performance of the process. The results showed that the CGE of the process was moderately high (51%) at 681°C, with a high syngas CV (4.45–4.89 MJ/Nm3) which was ideal for gas engine applications. The PKS gasification performance increased when the reactor temperature increased. Projections were made for the CGE and the syngas CV for the PKS gasification with increased reactor temperatures and it was found that these values could be increased up to 80% and 5.2 MJ/Nm3, respectively at a reactor temperature of 900°C. In addition, the estimated power that could be generated was about 600 kWe at a maximum operation of 500 kg/h of feed rate. Based on the analysis, a medium-scale PKS gasification is observed to be a promising process for power generation from biomass due to the favorable performance of the process.  相似文献   

18.
In most industrialized countries, environmental standards exist which prescribe the maximum allowable man-made increase in water temperature of a river. Together with flowrate and weather conditions, these standards determine the rate at which waste heat may be discharged into a river at any moment. Power generating stations with variable cooling systems can adjust their heat discharge into the river in compliance with environmental standards and by doing so exert an influence on power generation capacity. In this paper, a scheme is developed that allows a chain of power stations discharging into the same river to operate their cooling systems such that the output of total electricity is maximized and water temperature standards are accomodated. The optimum balance between stations is determined through dynamic programming. From the results of a simulation model using historical data, simple decision rules for day-to-day operation are abstracted. These rules are based solely on the river flow rates at each power station.  相似文献   

19.
ABSTRACT: Water supplies in Arizona are becoming increasingly limited because municipal, industrial, and agricultural consumption depletes ground water reserves by three million acre-feet annually. Additional demands are being created by electric power generation, particularly in northeastern Arizona where ground water pumpage is expected to escalate by sixfold during the next 10 years. The results of a study to determine the ease and feasibility of using satellite imagery as a tool in exploring for new sources of ground water are reported. Lineaments detected on Landsat images of two sites were mapped and correlated with well data in the two study areas by means of well centered grid model. The correlations developed between lineament density and water well data in the two study sites support the hypothesis that a relationship exists between regional geologic structure and the presence of ground water.  相似文献   

20.
着力防范化解环境社会风险是社会和谐稳定的重要前提。本文基于国内全网2019—2020年关于“垃圾焚烧”的网络舆情数据,通过情感词典、TF-IDF关键词提取和人工识别方法进行“邻避”冲突的原因分析,在此基础上构建本土化的“邻避”设施环境社会风险指标体系和评估方法,结合环境、人口和社会等多源大数据,基于自然断点法对风险等级进行分类,以全国生活垃圾焚烧发电设施的重点区域为案例开展环境社会风险的分析评估。结果表明,担忧破坏生态环境、反对选址位置、担忧排放物有毒是贯穿2019—2020年两年的主要反对原因,占据反对原因的50%以上。之后,本文对各项反对因素进行归纳汇总,构建了12项指标的风险评价指标体系,其中环境因素、人口因素和社会因素为一级指标,其权重分别达到0.33、0.49和0.18,人口因素是影响程度最大的因素;对案例风险评估结果表明全国范围和六大重点区域的大多数设施拟建设于重大风险或特大风险地区,需着重关注这些地区的生活垃圾焚烧发电项目规划布局和风险防控问题。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号