共查询到20条相似文献,搜索用时 78 毫秒
1.
2.
3.
采用电感耦合等离子体质谱法测定饮用水中的铅。采用在线加入内标的方法,消除基体效应,校正仪器接口效应。铅元素工作曲线的曲线方程为y=4.775E4x+5.311E2,线性相关系数为1.0000,空白溶液浓度低于方法检出限0.09 ug/L,RSD〈5%,RE〈3%,加标回收率在97.9%~110.8%。 相似文献
4.
采用电感耦合等离子体质谱仪测定水中的钴,在0μg/L~300μg/L范围内线性良好,相关系数均达到0.9999。该法对钴标准样品测定的结果在保证值范围。对三份不同浓度水样分别进行测定,其结果的RSD为0.2%~1.2%,空白水样的加标回收率在99%~107%之间。通过对水样的分析,符合标准要求,ICP-MS质谱仪具有灵敏度高,检出限低,取样量少,线性范围宽等特点,能快速测出水中的微量重金属元素含量。 相似文献
5.
6.
7.
8.
电感耦合等离子体发射光谱法(ICP-AES)测定水中钴 总被引:1,自引:0,他引:1
利用电感耦合等离子体发射光谱法测定水中钴,并优化了测定条件.结果表明,本方法检出限低,准确度高,精密度好. 相似文献
9.
电感耦合等离子体发射光谱法(ICP—AES)测定水中钴 总被引:1,自引:0,他引:1
利用电感耦合等离子体发射光谱法测定水中钴,并优化了测定条件。结果表明,本方法检出限低,准确度高,精密度好。 相似文献
10.
11.
氢化物发生-原子荧光法测定海水中痕量铅 总被引:2,自引:0,他引:2
以过硫酸铵为氧化剂将Pb氧化成亚稳四价态,与KBH4作用生成PbH4,应用氢化物发生原子荧光法测定海水中痕量Pb。本法灵敏度较高,检测限为0.63μg/L;其回收率在90%~105%之间;变异系数为2.1%~42%。 相似文献
12.
13.
A method was developed for the determination of total arsenic concentration in less than ng/ml level by decomposition of organoarsenicals using photo -oxidation combined with in situ trapping of arsenic hydride on a palladium coated graphite tube with subsequent atomization and detection by AAS. The organoarsenicals include monomethylarsenic, dimethylarsenic, arsenobetaine, arsenocholine, o -aminobenzenarsenate and p -aminobenzenarsenate. The method is simple and sensitive. Detection limit was obtained from different arsenic compounds over the range from 0. 058 to 0.063 ng/ml as As (based on three times of the standard deviation of 10 blank measurements) and the relative standard deviations for ten replicate measurements were from 2.0 to 3.8%. The calibration curves of arsenic compounds including inorganic and organic arsenicals were linear over the range from 0.1 to 3.0 ng/ml as As. The recommended method has been applied to the determination of total arsenic in tap and lake water samples at ng/ml leve 相似文献
14.
15.
16.
悬浮液-流动注射-氢化发生原子荧光法测定沉积物中的Pb 总被引:2,自引:0,他引:2
研究了一种把悬浮液进样与氢化发生相结合原子荧光光谱法测定沉积物中Pb的方法。控制悬浮液的粒径在0.088mm以下,用磁力搅拌器搅拌以保证悬浮液分散均匀稳定,方法中以盐酸作介质,K3Fe(CN)6为氧化剂,采用水溶液标准作标准曲线测定了沉积物中的Pb,该法的线性范围为0~200μg/L,检出限为0.26μg/L,回收率为92%~107%,精密度小于6.5%。将此法用于标准物质的分析,测定值均在标准值范围之内,结果令人满意,具有实际应用价值。 相似文献
17.
A group parameter approach using "total organic halogen" is effective for monitoring gaseous organic halogen compounds, including fluorine, chlorine, and bromine compounds, generated from combustion. We described the use of barrier-discharge radiofrequency- helium-plasma/atomic emission spectrometry, for the detection of semi- and low-volatile organic halogen compounds (SLVOXs), which can be collected by Carbotrap TM adsorbents and analyzed using thermal desorption. The optimal carrier gas flow rates at the injection and desorption lines were established to be 100 mL/min. The detection range for SLVOXs in the gaseous samples was from 10 ng to tens of micrograms. Measuring F was more difficult than measuring Cl or Br, because the wavelength of F is close to that of air. The barrier- discharge radiofrequency-helium-plasma/atomic emission spectrometry measured from 85% to 103% of the SLVOXs in the gas sample. It has been found that Carbotrap B is appropriate for high-boiling-point compounds, and Carbotrap C is suitable for the determination of organic halogen compounds with lower boiling points, in the range 200-230°C. Under optimal analysis conditions, a chlorine- containing plastic was destroyed using different oxygen concentrations. Lower oxygen concentrations resulted in the production of lower amounts of organic halogen compounds. 相似文献
18.
19.
悬浮液进样原子荧光光谱法测定海洋沉积物样品中的痕量汞 总被引:2,自引:1,他引:2
研究了一种使用悬浮液进样原子荧光光谱法测定海洋沉积初中痕量汞的快速简便的方法。控制悬浮液的颗粒粒径在200目(d≤0.076mm),用磁力搅拌器搅拌以保证悬浮液分散均匀稳定,以水溶液标准作标准曲线,该法方法的检出限为0.001μg/L,加标回收率为90.5%-103.4%,RSD为4.39%。将此法用于标准物质GBw07314、GBw08301、GSBZ50013—88、GSB50014—88和实验室外控样的分析,得到了满意的结果,证明该方法准确可靠。 相似文献
20.
HPLC分离-氢化物发生-动态反应池-ICP/MS联用分析废水中砷形态 总被引:2,自引:0,他引:2
采用高效液相色谱(HPLC)分离水中不同的砷物种,将串联进入氢化物发生(HG)-动态反应池(DRC)-电感耦合等离子体质谱仪(HPLC-HG-ICP-DRC-MS)系统进行检测,由此建立了废水中砷形态的分析方法,并探讨了最佳测试条件,最后对宁波部分地区废水中砷形态分布规律进行了初步探讨.结果表明,以0.04 mol·L-1L半胱氨酸(L-cys)、0.132 mol·L-1NaBH4和体积分数2%的HCl作为氢化物发生器载液,以H2作为DRC-ICP-MS反应气,控制流速为1.5mL·min-1时,4种As物种都有最佳的氢化物发生效率,且其它金属离子对分析干扰可忽略不计,求得As(Ⅲ)、As(Ⅴ)、单甲基砷(MMA)、双甲基砷(DMA)的检测下限(3倍噪音)分别为0.003、0.001、0.002、0.004 μg·L-1.此系统可成功测定废水中砷的形态. 相似文献