首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lai CL  Lin SH 《Chemosphere》2004,54(3):235-242
Treatment of copper chemical mechanical polishing (CMP) wastewater from a semiconductor plant by electrocoagulation is investigated. The CMP wastewater was characterized by high suspended solids (SS) content, high turbidity (NTU), chemical oxygen demand (COD) concentration up to 500 mgl(-1) and copper concentration up to 100 mgl(-1). In the present study, electrocoagulation was employed to treat the CMP wastewater with an attempt to simultaneously lower its turbidity, copper and COD concentrations. The test results indicated that electrocoagulation with Al/Fe electrode pair was very efficient and able to achieve 99% copper ion and 96.5% turbidity removal in less than 30 min. The COD removal obtained in the treatment was better than 85%, with an effluent COD below 100 mgl(-1). The effluent wastewater was very clear and its quality exceeded the direct discharge standard. In addition, sludge settling velocities after electrocoagulation were measured and the data were employed to verify the empirical sludge settling velocity models. Finally, the sludge settling characteristic data were also utilized to establish the relation between the solids flux (G) and the initial solids concentration.  相似文献   

2.
竹丝生物膜法和生态床组合工艺废水处理的试验研究   总被引:1,自引:0,他引:1  
研究了竹丝生物膜法和生态床组合工艺处理模拟废水,讨论了该组合工艺对模拟废水中COD、氨氮和浊度的去除效果,着重讨论了生态床处理效果的影响因子。试验结果表明,竹丝生物膜法能很好地去除COD、氨氮和浊度等,在水温为9.0~10.5℃、水力停留时间为5.0h、进水COD为98.78~222.69mg/L、氨氮为5.46~12.97mg/L、浊度为26.42~59.84NTU时,出水COD为11.53~20.38mg/L,氨氮为0.42~0.86mg/L,浊度为12.38~17.30NTU。竹丝生物膜法出水再经过简易的生态床工艺,生态床出水COD为9.59~18.84mg/L,氨氮为0.43~0.90mg/L,浊度为6.77~14.15NTU;在此过程中发现,生态床中的鱼类对浊度和COD的去除均有明显效果,而光合作用对生态床COD的去除有促进作用,但是生态床对氨氮浓度却有升高作用。  相似文献   

3.
The capacity to reach lower bounds for extraction of pollutants from wastewater by four floating aquatic macrophytes--water hyacinth (Eichhornia crassipes), water lettuce (Pistia stratiotes), salvinia (Salvinia rotundifolia), and water primroses (Ludvigia palustris)--is investigated. It is shown that the following lower bounds can be established for wastewater purification with water hyacinth: biochemical oxygen demand (BOD), 1.3 mg/L; chemical oxygen demand (COD), 11.3 mg/L; total suspended solids (TSS), 0.5 mg/L; turbidity, 0.7 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.4 mg/L. Also, the following lower bounds can be established for wastewater purification with water lettuce: BOD, 1.8 mg/L; COD, 12.5 mg/L; TSS, 0.5 mg/L; turbidity, 0.9 NTU; ammonia, 0.2 mg/L; and phosphorus, 1.6 mg/L. These lower bounds were reached in 11- to 17-day experiments that were performed on diluted wastewater with reduced initial contents of the tested water quality indicators. As expected, water hyacinth exhibited the highest rates and levels of pollutant removal, thereby producing the best lower bounds of the water quality indicators. Given the initially low levels, BOD was further reduced by 86.3%, COD by 66.6%, ammonia by 97.8%, and phosphorus by 65.0% after 11 days of a batch experiment. The capacity of water plants to purify dilute wastewater streams opens new options for their application in the water treatment industry.  相似文献   

4.
加热酸化-Fenton氧化处理乳化液废水   总被引:1,自引:0,他引:1  
采用加热酸化-Fenton氧化处理乳化液废水,在加酸量为1.0mL98%H2SO4/100mL乳化液、加热温度95℃、加热时间1h条件下,初始COD〉20万mg/L,浊度〉8000NTU的乳化液COD降低到46592mg/L,浊度降低到20NTU,加热和酸化的联合过程达到了良好的破乳效果;破乳后的出水在ρ(Fe2+)/ρ(H2O2)=1:30、ρ(H2O2)和(COD)=1.4、pH=4的条件下进行Fenton氧化,处理后的出水COD可降到18600mg/L,去除率达61.4%,其B/C可由破乳后的0.11提高到0.43,废水的可生化性大大提高,为后续处理创造了可能。  相似文献   

5.
丁然  潘峰  高迎新  张昱 《环境工程学报》2012,6(5):1624-1628
采用聚合硫酸铁复配高锰酸钾混凝结合二氧化氯氧化的组合工艺成功解决了某厂聚氯乙烯生产废水回收工艺CODMn不达标问题。工程运行结果表明,当原水CODMn=30~48 mg/L,浊度=25~46 NTU时,在CFe=16.8 mg/L,CKMnO4=45 mg/L,CClO2=20 mg/L的条件下,出水CODMn<10 mg/L,浊度<0.5 NTU,达到工业循环补给水的水质要求。  相似文献   

6.
Textile plant wastewater being treated in a facultative pond system had too high of a solids concentration to be reused in the dying and rinsing processes. Electrocoagulation was evaluated to further treat the pond effluent to remove turbidity, which was caused by dyes and microorganisms. A range of amperages were tested for removal of turbidity and chemical oxygen demand (COD). Electrocoagulation lowered the turbidity from 1400 NTU to below 50 NTU; and COD was lowered from 550 mg/L to approximately 250 mg/L, which was acceptable for reuse. In addition, a laboratory-scale sedimentation study was conducted on the electrocoagulated pond effluent, which indicated that a settling time of 35 minutes would provide for 80% removal of suspended solids, which was acceptable for reuse of the water in plant processes.  相似文献   

7.
混凝法深度处理废纸造纸废水实验研究   总被引:4,自引:2,他引:2  
按照烧杯实验方法,重点考察了pH值、混凝剂种类和投加量等因素对生化处理后废纸造纸废水混凝处理效果的影响。实验结果表明:PAC作为混凝剂,PAM作为助凝剂联合处理该废水时,能够取得较好的去浊率、SS、色度和COD去除率。混凝沉淀最佳运行条件为:废水pH为6.5,含铝量10%的PAC和2 g/L的PAM投加量分别为1 mL/L、0.5 mL/L,浊度从35 NTU降低到1 NTU,去除率达97.1%,SS从30 mg/L降低到7 mg/L,去除率达76.7%,色度从64倍降低到18倍,去除率达71.9%,COD从95 mg/L降低到44.8 mg/L,去除率可达52.8%,取得了较好的去除效果,达到国家造纸废水新排放标准限值。  相似文献   

8.
针对某钼矿选矿厂浮选废水,以PAC、PFS和FeCl3为凝聚剂,以APAM-A和APAM-N为絮凝剂,以H2SO4和NaOH为pH调整剂,研究了不同混凝剂、不同pH值和不同水力条件下废水处理后的浊度和COD.实验结果表明,在最佳水力条件下,原水pH不调整,以APAM-A为絮凝剂,以PAC为凝聚剂,其用量分别为15 g/t,750g/t时,处理后上清液浊度为25 NTU,COD小于30 mg/L.浮选废水经处理后回用于选矿浮选流程,大大改善了选矿指标.  相似文献   

9.
低温环境下内置腐殖土填料SBR系统处理糠醛废水   总被引:1,自引:0,他引:1  
在水温为5~10℃左右的条件下,通过实验对比了传统SBR系统与内置腐殖土填料式SBR系统处理糠醛废水的效能,结果表明:由于内置腐殖土填料的作用,填料式SBR系统的去除效能要高于未装填料的SBR系统;传统SBR系统的COD、氨氮和总氮的去除率分别为89%、85%和59%,出水浊度为8.6 NTU;填料式SBR系统的COD、氨氮和总氮的去除率分别为95%、90%和71%,出水浊度为1.7 NTU。  相似文献   

10.
The possibilities of application of a three-step system combining hybrid biological treatment followed by advanced UV/O3 oxidation with in situ generated O3 and membrane separation (ultrafiltration (UF) and nanofiltration (NF)) to treat and reuse the wastewater from an industrial laundry are presented. By the application of a hybrid moving bed biofilm reactor (HMBBR), the total organic carbon concentration was reduced for about 90 %. However, since the HMBBR effluent still contained organic contaminants as well as high concentrations of inorganic ions and exhibited significant turbidity (8.2 NTU), its further treatment before a possible reuse in the laundry was necessary. The UV/O3 pretreatment prior to UF was found to be an efficient method of the membrane fouling alleviation. During UF, the turbidity of wastewater was reduced below 0.3 NTU. To remove the inorganic salts, the UF permeate was further treated during NF. The NF permeate exhibited very low conductivity (27–75 μS/cm) and contained only small amounts of Ca2+ and Mg2+; thus ,it could be reused at any stage of the laundry process.  相似文献   

11.
反冲洗周期是生物除铁除锰滤池的一个重要运行参数,实验中分别设定反冲洗周期为24、48和72 h,考察反冲洗周期对成熟稳定运行的滤柱出水铁、锰、氨氮和浊度的影响。结果表明,不同反冲洗周期,滤柱对铁、锰和氨氮均有很好的去除效果,出水中的总Fe、Mn2+和NH4+-N的平均浓度分别为0.018、0.003和0.016 mg/L,0.010、0.001和0.014 mg/L,0.013、0.001和0.014 mg/L,均远低于国家标准,说明反冲洗周期变化对三者的去除效果没有影响。反冲洗周期为24、48和72 h时,出水平均浊度分别为0.27、0.38和0.57 NTU,反冲洗周期越长,出水浊度越高。滤柱沿程浊度分析发现,浊度主要在0~0.4 m去除,出水浊度与滤层厚度无关。反冲洗后5 min出水浊度为3.16 NTU,15 min降到了1 NTU以下,25 min降到了0.5 NTU,60 min大约降到了反冲洗前的水平。  相似文献   

12.
反冲洗周期是生物除铁除锰滤池的一个重要运行参数,实验中分别设定反冲洗周期为24、48和72h,考察反冲洗周期对成熟稳定运行的滤柱出水铁、锰、氨氮和浊度的影响。结果表明,不同反冲洗周期,滤柱对铁、锰和氨氮均有很好的去除效果,出水中的总Fe、Mn“和NH?-N的平均浓度分别为0.018、0.003和0.016mg/L,0.010、0.001和0.014mg/L,0.013、0.001和0.014mg/L,均远低于国家标准,说明反冲洗周期变化对三者的去除效果没有影响。反冲洗周期为24、48和72h时,出水平均浊度分别为0.27、0.38和0.57NTU,反冲洗周期越长,出水浊度越高。滤柱沿程浊度分析发现,浊度主要在0~O.4m去除,出水浊度与滤层厚度无关。反冲洗后5rain出水浊度为3.16NTU,15min降到了1NTU以下,25min降到了0.5NTU,60min大约降到了反冲洗前的水平。  相似文献   

13.
针对碱度大、COD高、组成复杂的碱减量-印染混合废水,采用高碱度下直接混凝再酸析相结合的方法进行预处理,取得理想效果.试验结果表明,在高碱度条件下先加入镁盐及少量高分子絮凝剂,可去除大部分可溶性及不溶性污染物;再通过降低pH的酸析法,能有效去除废水中的色度、浊度,大大降低COD.在MgSO4用量为800~1 500 mg/L,阴离子聚丙烯酰胺用量为2 mg/L,酸析pH小于3.0时,色度去除率达97%,COD去除率达92%,浊度去除率近100%.  相似文献   

14.
城市污水厂二级处理出水深度处理组合工艺研究   总被引:2,自引:0,他引:2  
为了研究臭氧-曝气生物滤池二级处理出水深度处理组合工艺的处理效果,采用臭氧-曝气生物滤池(biological aerated filter, BAF)组合工艺对城市污水处理厂二级生化处理出水进行深度处理。结果表明,组合工艺对造成水中色度的主要物质腐植酸和富里酸类有机物和嗅味物质中的二甲基三硫和二甲基异莰醇(MIB)能够进行有效去除。臭氧氧化能够显著提高后续BAF单元对CODMn的去除。在进水CODMn6~8 mg/L、色度为25~30度、浊度约为8 NTU的条件下,当臭氧投加量为5~6 mg/L、BAF的水力停留时间为1~1.5 h时,出水CODMn< 5 mg/L、色度<5度、浊度<1 NTU,出水水质可满足生产工艺对回用水的水质要求。  相似文献   

15.
Struvite precipitation has increasing interest as a technology for removing and recovering phosphorus from wastewater streams. Many chemical factors have been studied, such as optimum pH values and component-ion molar ratios, yet, understanding of physical aspects is lacking. Two physical parameters were tested: (1) seeding material addition and (2) mixing. Objectives were to evaluate three seeding materials and to optimize mixing conditions for struvite-crystal precipitation, growth, and subsequent sedimentation. Results confirm that mixing strength and proper seeding materials increase crystal size and improve settleability. For unseeded solutions, optimum phosphorus removal was achieved at a mixing strength of G = 76 s(-1). Struvite crystals that were added as the seeding material provided the best performance with respect to phosphorus removal and crystal-size distribution. Overall, this study provided information to improve the practical application of struvite precipitation as a phosphorous-treatment technology for wastewaters, while generating a marketable slow-release fertilizer as a product.  相似文献   

16.
用糖蜜废水取代葡萄糖作为发酵培养基中的碳源和能源培养微生物絮凝剂产生菌Pseudomonas alcaligenesPS-25。通过单因素试验和正交试验得到该菌株产絮凝剂的最佳培养条件:糖蜜废水COD浓度5 000 mg/L、培养基初始pH值6.5、接种量5%(体积比)、温度30℃、培养时间为72 h、摇床转速160 r/min,在此条件下,PS-25所产絮凝剂对高岭土悬浊液絮凝率达96.75%,并且对多种废水都有较好的净化效果,对废水中浊度和色度的去除率分别在90%和80%以上,COD去除率在73.60%~91.10%。研究表明,用糖蜜废水培养PS-25生产微生物絮凝剂处理废水是完全可行的,从而实现废物的资源化利用。  相似文献   

17.
The textile industry is one of the most rapidly developing industries in Turkey. It generates a large amount of wastewater, with corresponding concerns about pollution. The main sources of pollution in wastewater are the dyeing and finishing processes. The dyestuffs and polyvinyl alcohol (PVA) are the main refractory organics of concern in terms of meeting more stringent effluent standards of chemical oxygen demand (COD) and colour. In this study, wastewaters from textile dyeing factories in Bursa were characterised, and physical, chemical and biological treatability studies were carried out. In the physical and chemical studies, 60.80% COD, 80% suspended solids (SS) and 10.92% turbidity removal efficiencies were obtained. In the biological studies, 90% COD and 40% SS removal were obtained. The initial soluble inert COD of wastewater was determined by using comparison methods. The initial inert COD of wastewater and the microbial product concentration were determined as 37 mg/l and 13 mg/l, respectively.  相似文献   

18.
厌氧-好氧工艺处理制药废水的中试研究   总被引:3,自引:0,他引:3  
将由厌氧折流板反应器(ABR)、移动床生物膜反应器(MBBR)和膜生物反应器(MBR)组合而成的厌氧-好氧工艺用于处理制药废水的中试研究.试验结果表明,当原水SS平均值为1000 mg/L,COD为10 000 mg/L,NH3-N为500 mg/L时,出水浊度、COD和NH3-N分别为3 NTU、500 mg/L以及10 mg/L以下,去除率分别为98%、95%和98%以上.  相似文献   

19.
聚合氯化铝与粉末活性炭联合强化混凝处理垃圾渗滤液   总被引:1,自引:0,他引:1  
研究了联合粉末活性炭与聚合氯化铝(PAC)强化混凝对垃圾渗滤液原水的处理效果。结果表明,在原水COD为4 100 mg/L、浊度为147 NTU、UV254为20的条件下,粉末活性炭的加入可以有效增加垃圾渗滤液中有机物的去除率,PAC投加量为0.6 g/L时,投加0.6 g/L粉末活性炭,COD的去除率由21.6%提高到29.1%,UV254去除率由29.8%提高到39.9%,剩余浊度由138 NTU降到133 NTU。该强化混凝过程使原水中溶解性小分子有机物的去除率提高显著,PAC投加量为0.6 g/L时,投加0.6 g/L粉末活性炭,在分子量小于1 kDa的范围内,UV254去除率由2.9%上升为10%。  相似文献   

20.
Although the long incubation time of biochemical oxygen demand (BOD7) measurements has been addressed by the use of microbial biosensors, the resulting sensor-BOD values gained from the measurements with specific industrial wastewaters still underestimates the BOD value of such samples. This research aims to provide fast and more accurate BOD measurements in the dairy wastewater samples. Unlike municipal wastewater, wastewater from the dairy industry contains many substrates that are not easily accessible to a majority of microorganisms. Therefore, a bacterial culture, Microbacterium phyllosphaerae, isolated from dairy wastewater was used to construct a semi-specific microbial biosensor. A universal microbial biosensor based on Pseudomonas fluorescens, which has a wide substrate spectrum but is nonspecific to dairy wastewater, was used as a comparison. BOD biosensors were calibrated with OECD synthetic wastewater, and experiments with different synthetic and actual wastewater samples were carried out. Results show that the semi-specific M. phyllosphaerae-based microbial biosensor is more sensitive towards wastewaters that contain milk derivates and butter whey than the P. fluorescens-based biosensor. Although the M. phyllosphaerae biosensor underestimates the BOD7 value of actual dairy wastewaters by 25–32 %, this bacterial culture is more suitable for BOD monitoring in dairy wastewater than P. fluorescens, which underestimated the same samples by 46–61 %.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号