首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
Effect of substrate Henry's constant on biofilter performance   总被引:4,自引:0,他引:4  
Butanol, ether, toluene, and hexane, which have Henry's constants ranging from 0.0005 to 53, were used to investigate the effects of substrate solubility or availability on the removal of volatile organic compounds (VOCs) in trickle-bed biofilters. Results from this study suggest that, although removal of a VOC generally increases with a decrease in its Henry's constant, an optimal Henry's constant range for biofiltration may exist. For the treatment of VOCs with high Henry's constant values, such as hexane and toluene, the transfer of VOCs between the vapor and liquid phases or between the vapor phase and the biofilm is a rate-determining step. However, oxygen (O2) transfer may become a rate-limiting step in treating VOCs with low Henry's constants, such as butanol, especially at high organic loadings. The results demonstrated that in a gas-phase aerobic biofilter, nitrate can serve both as a growth-controlling nutrient and as an electron acceptor in a biofilm for the respiration of VOCs with low Henry's constants. Microbial communities within the biofilters were examined using denaturing gradient gel electrophoresis to provide a more complete picture of the effect of O2 limitation and denitrification on biofilter performance.  相似文献   

2.
Henry's law constants (H) are needed to model human exposure to Volatile Organic Compounds (VOCs) in indoor air resulting from the use of tap water. This paper presents an experimental method to determine Hs for several common tap water pollutants at concentrations and temperatures used in household water. For 5 VOCs Henry's law constants were obtained simultaneously over the 25 degrees C to 45 degrees C temperature range, providing data on H beyond the currently available data (up to 35 degrees C). Henry's law constants were obtained as the ratio of equilibrium concentrations of VOCs in air and water, using simultaneous sampling from sealed bottles kept at constant temperatures. Air and water samples were concentrated by a purge-and-trap method, thermally desorbed from a Tenax trap, and analyzed with a gas chromatograph with an electron capture detector (GC-ECD). Experimental results agreed well with available literature data.  相似文献   

3.
An activated sludge aeration tank (40 x 40 x 300 cm, width x length x height) with a set of 2-mm orifice air spargers was used to treat gas-borne volatile organic compounds (VOCs; toluene, p-xylene, and dichloromethane) in air streams. The effects of liquid depth (Z), aeration intensity (G/A), the overall mass-transfer rate of oxygen in clean water (KLaO2), the Henry's law constant of the tested VOC (H), and the influent gaseous VOC concentration (C0) on the efficiency of removal of VOCs were examined and compared with a literature-cited model. Results show that the measured VOC removal efficiencies and those predicted by the model were comparable at a G/A of 3.75-11.25 m3/m2 hr and C0 of approximately 1000-6000 mg/m3. Experimental data also indicated that the designed gas treatment reactor with KLaO2 = 5-15 hr(-l) could achieve > 85% removal of VOCs with H = 0.24-0.25 at an aerated liquid depth of 1 m and > 95% removal of dichloromethane with H = 0.13 at a 1-m liquid depth.  相似文献   

4.
Environmental Science and Pollution Research - Cyclodextrins (CDs) and deep eutectic solvents (DESs) are emerging absorbent materials for the removal of volatile organic compounds (VOCs). In this...  相似文献   

5.
选择柠檬酸钠水溶液、Tween-20水溶液、檬酸钠-Tween-20混合水溶液、新型矿物油及新型矿物油-水作为研究对象,实验研究对比了几种吸收剂对甲苯废气的吸收效果。通过实验分析可知,檬酸钠水体系对甲苯废气吸收能力有限,加入盐类可小幅增强其水体系对于甲苯废气的吸收效果,其中Tween-20水溶液吸收剂对甲苯废气吸收率较柠檬酸钠水体系高;新型矿物油对甲苯废气有着较好的处理效果,吸收率最高可达97%,而新型矿物油-水混合吸收剂中单位体积新型矿物油对甲苯废气吸收率较新型矿物油吸收剂提高45%,且具有吸收效率高、分散性好、再生成本低的优点。  相似文献   

6.
Volatile organic compounds (VOCs) in urban atmosphere of Hong Kong   总被引:21,自引:0,他引:21  
Lee SC  Chiu MY  Ho KF  Zou SC  Wang X 《Chemosphere》2002,48(3):375-382
The assessment of volatile organic compounds (VOCs) has become a major issue of air quality network monitoring in Hong Kong. This study is aimed to identify, quantify and characterize volatile organic compounds (VOCs) in different urban areas in Hong Kong. The spatial distribution, temporal variation as well as correlations of VOCs at five roadside sampling sites were discussed. Twelve VOCs were routinely detected in urban areas (Mong Kok, Kwai Chung, Yuen Long and Causeway Bay). The concentrations of VOCs ranged from undetectable to 1396 microg/m3. Among all of the VOC species, toluene has the highest concentration. Benzene, toluene, ethylbenzene and xylenes (BTEX) were the major constituents (more than 60% in composition of total VOC detected), mainly contributed from mobile sources. Similar to other Asian cities, the VOC levels measured in urban areas in Hong Kong were affected both by automobile exhaust and industrial emissions. High toluene to benzene ratios (average T/B ratio = 5) was also found in Hong Kong as in other Asian cities. In general, VOC concentrations in the winter were higher than those measured in the summer (winter to summer ratio > 1). As toluene and benzene were the major pollutants from vehicle exhausts, there is a necessity to tighten automobile emission standards in Hong Kong.  相似文献   

7.
Arion A  Baronnet F  Lartiges S  Birat JP 《Chemosphere》2001,42(5-7):853-859
In order to characterize the compounds (type and quantities) emitted during melting of organic contaminated scrap and to investigate the mechanism of their formation, an experimental set-up has been designed and built to study precisely the influence of temperature and gas atmosphere in the conditions of an electric arc furnace. These experiments lead to the determination of mass balances (C, H, O, S) and to the quantification of unburnt compounds (tars, carbon monoxide, volatile organic compounds (VOCs), benzene, toluene, ethylbenzene and xylenes (BTEX), polyaromatic compounds (PAHs)). Degradation conditions (gas atmosphere and temperature) corresponding to different areas in the electric furnace have also been investigated. Such experiments lead to a better understanding of degradation mechanisms; this interpretation is not possible from investigations performed in an industrial furnace since there are many uncontrolled parameters (large dispersion of the results).  相似文献   

8.
Volatile organic compounds (VOCs) commonly detected in urban waters across the United States include gasoline-related compounds (e.g. toluene, xylene) and chlorinated compounds (e.g. chloroform, tetrachloroethane [PCE], trichloroethene [TCE]). Statistical analysis of observational data and results of modeling the partitioning of VOCs between air and water suggest that urban land surfaces are the primary nonpoint source of most VOCs. Urban air is a secondary nonpoint source, but could be an important source of the gasoline oxygenate methyl-tert butyl ether (MTBE). Surface waters in urban areas would most effectively be protected by controlling land-surface sources.  相似文献   

9.
Jo WK  Park KH 《Chemosphere》2004,57(7):555-565
The current study evaluated the technical feasibility of applying TiO2 photocatalysis to the removal of low-ppb concentrations of volatile organic compounds (VOCs) commonly associated with non-occupational indoor air quality issues. A series of experiments was conducted to evaluate five parameters (relative humidity (RH), hydraulic diameter (HD), feeding type (FT) for VOCs, photocatalytic oxidation (PCO) reactor material (RM), and inlet port size (IPS) of PCO reactor) in relation to the PCO destruction efficiencies of the selected target VOCs. None of the target VOCs exhibited any significant dependence on the RH, which is inconsistent with a previous study where, under conditions of low humidity and a ppm toluene inlet level, a drop in the PCO efficiency was reported with a decreasing humidity. However, the other four parameters (HD, RM, FT, and IPS) were found to be important for better VOC removal efficiencies as regards the application of TiO2 photocatalytic technology for cleansing non-occupational indoor air. The PCO destruction of VOCs at concentrations associated with non-occupational indoor air quality issues was up to nearly 100%, and the CO generated during PCO was a negligible addition to indoor CO levels. Accordingly, a PCO reactor would appear to be an important tool in the effort to improve non-occupational indoor air quality.  相似文献   

10.
Volatile organic compounds (VOCs) are found in indoor air, and many of these can affect human health (e.g. formaldehyde and benzene are carcinogenic). Plants affect the levels of VOCs in indoor environments, thus they represent a potential green solution for improving indoor air quality that at the same time can improve human health. This article reviews scientific studies of plants’ ability to remove VOCs from indoor air. The focus of the review is on pathways of VOC removal by the plants and factors affecting the efficiency and rate of VOC removal by plants. Laboratory based studies indicate that plant induced removal of VOCs is a combination of direct (e.g. absorption) and indirect (e.g. biotransformation by microorganisms) mechanisms. They also demonstrate that plants’ rate of reducing the level of VOCs is influenced by a number of factors such as plant species, light intensity and VOC concentration. For instance, an increase in light intensity has in some studies been shown to lead to an increase in removal of a pollutant. Studies conducted in real-life settings such as offices and homes are few and show mixed results.  相似文献   

11.
Abstract

The use of sorbents has been proposed to remove volatile organic compounds (VOCs) present in ambient air at concentrations in the parts-per-billion (ppb) range, which is typical of indoor air quality applications. Sorbent materials, such as granular activated carbon and molecular sieves, are used to remove VOCs from gas streams in industrial applications, where VOC concentrations are typically in the parts-per-million range. A method for evaluating the VOC removal performance of sorbent materials using toluene concentrations in the ppb range is described. Breakthrough times for toluene at concentrations from 2 to 7500 ppb are presented for a hydrophobic molecular sieve at 25% relative humidity. By increasing the ratio of challenge gas flow rate to the mass of the sorbent bed and decreasing both the mass of sorbent in the bed and the sorbent particle size, this method reduces the required experimental times by a factor of up to several hundred compared with the proposed American Society of Heating, Refrigerating, and Air-Conditioning Engineers method, ASHRAE 145P, making sorbent performance evaluation for ppb-range VOC removal more convenient. The method can be applied to screen sorbent materials for application in the removal of VOCs from indoor air.  相似文献   

12.
This study analyzes the volatile organic compounds (VOCs) in the ambient air around gasoline stations during rush hours and assesses their impact on human health. Results from this study clearly indicate that methyl tertiary butyl ether (MTBE), toluene, and isobutane are the major VOCs emitted from gasoline stations. Moreover, the concentrations of MTBE and toluene in the ambient air near gasoline stations are remarkably higher than those sampled on surrounding roads, revealing that these compounds are mainly released from gasoline stations. The concentration of VOCs near the gasoline stations without vapor recovery systems are approximately 7.3 times higher than those around the gasoline stations having the recovery systems. An impact on individual health and air quality because of gasoline station emissions was done using Integrated Risk Information System and Industrial Source Complex Short Term model.  相似文献   

13.
The use of sorbents has been proposed to remove volatile organic compounds (VOCs) present in ambient air at concentrations in the parts-per-billion (ppb) range, which is typical of indoor air quality applications. Sorbent materials, such as granular activated carbon and molecular sieves, are used to remove VOCs from gas streams in industrial applications, where VOC concentrations are typically in the parts-per-million range. A method for evaluating the VOC removal performance of sorbent materials using toluene concentrations in the ppb range is described. Breakthrough times for toluene at concentrations from 2 to 7500 ppb are presented for a hydrophobic molecular sieve at 25%) relative humidity. By increasing the ratio of challenge gas flow rate to the mass of the sorbent bed and decreasing both the mass of sorbent in the bed and the sorbent particle size, this method reduces the required experimental times by a factor of up to several hundred compared with the proposed American Society of Heating, Refrigerating, and Air-Conditioning Engineers method, ASHRAE 145P, making sorbent performance evaluation for ppb-range VOC removal more convenient. The method can be applied to screen sorbent materials for application in the removal of VOCs from indoor air.  相似文献   

14.
Starokozhev E  Sieg K  Fries E  Püttmann W 《Chemosphere》2011,82(10):1482-1488
Laboratory experiments were performed to investigate the partitioning behavior of a set of diverse volatile organic compounds (VOCs). After equilibration at a temperature of 25 °C, the VOC concentrations were measured by headspace method in combination with gas chromatography/mass spectrometry (GC/MS). The obtained data were used to determine the partition coefficients (KP) of VOCs in a gas-liguid-solid system. The results have shown that the presence and nature of solid materials in the working solution control the air-water partitioning of dissolved VOCs. The air/solution partitioning of BTEX and C9-C10 aldehydes was most affected in the presence of diesel soot. KP values decreased by a factor ranging from 1.5 for toluene to 3.0 for ethylbenzene. The addition of mineral dust in the working solution exhibited greater influence on the partitioning of short aldehydes. KP values decreased by a factor of 1.8. The experimental partition coefficients were used to develop a predictive model for partitioning of BTEX and n-aldehydes between air, water and solid phases.  相似文献   

15.
The photo-Fenton reaction was applied as a novel method for the removal of volatile organic compounds (VOCs) in the gas phase, and its effectiveness was experimentally examined. In conventional VOCs removal methods using a photocatalyst or ozone, VOCs are oxidized in the gas phase. Therefore, incompletely oxidized intermediates, which may have adverse effects on health, are likely to contaminate the treated air. On the other hand, in the VOCs removal method developed in this study, because the VOCs are oxidized in the liquid phase by the photo-Fenton reaction, any incompletely oxidized intermediates produced are confined to the liquid phase. As a result, the contamination of the treated air by these harmful intermediates can be prevented. Using a semi-batch process, it was found that the removal efficiency for toluene in a one-pass test (residence time of 17 s) was 61%, for an inlet toluene gas concentration of 930 ppbv, an initial iron ion concentration of 20 mg L−1, and an initial hydrogen peroxide concentration of 630 mg L−1. The removal efficiency was almost constant as long as H2O2 was present in the solution. Proton transfer reaction mass spectrometry analysis confirmed the absence of any incompletely oxidized intermediates in the treated air.  相似文献   

16.
Abstract

This study analyzes the volatile organic compounds (VOCs) in the ambient air around gasoline stations during rush hours and assesses their impact on human health. Results from this study clearly indicate that methyl tertiary butyl ether (MTBE), toluene, and isobutane are the major VOCs emitted from gasoline stations. Moreover, the concentrations of MTBE and toluene in the ambient air near gasoline stations are remarkably higher than those sampled on surrounding roads, revealing that these compounds are mainly released from gasoline stations. The concentration of VOCs near the gasoline stations without vapor recovery systems are ~7.3 times higher than those around the gasoline stations having the recovery systems. An impact on individual health and air quality because of gasoline station emissions was done using Integrated Risk Information System and Industrial Source Complex Short Term model.  相似文献   

17.
The Henry's law constant is important in the gas-liquid mass transfer process. Apparent dimensionless Henry's law constant, or the gas-liquid partition coefficient (K'H), for both hydrophilic (methanol, isopropyl alcohol, and acetone) and hydrophobic (toluene and p-xylene) organic compounds in deionized (DI) water, a wastewater with a maximum total dissolved organic carbon (DOC) content of 700 mg/L, and DI water mixed with a maximum activated sludge suspended solid (SS) concentration of 40,000 mg/L were measured using the single equilibrium technique at 293 K. Experimental results demonstrate that the K'H of any of the test volatile organic compounds varied among three situations. First, the K'H of the hydrophilic compounds in mixed liquor with the maximum SS concentration was 9-21% higher than those in DI water. Second, those for toluene and p-xylene were 77% and 93% lower, respectively, in the mixed liquor with the maximum SS concentration. Third, the K'H values of all of the test compounds in the wastewater were only 10% lower than those in DI water. A model was developed to relate K'H with wastewater DOC and the SS concentration in the activated sludge using an organic carbon-water partition coefficient and activated sludge-water partition coefficient as model parameters. The model was verified and model parameters for test compounds estimated.  相似文献   

18.
Volatile organic compounds in selected micro-environments   总被引:1,自引:0,他引:1  
A program of sampling for volatile organic compounds (VOCs) in ambient air was undertaken in selected locations and micro-environments in Perth, Western Australia to characterise concentrations of target VOCs and to determine the relative strength of the contributing sources to ambient air in different micro-environments in a major Australian city. Twenty-seven locations were sampled and, of the forty-one target compounds, 26 VOCs were detected in the samples collected. The highest concentrations were recorded for benzene, toluene, ethylbenzene, xylenes (BTEX), chloroform and styrene. The maximum 12-h toluene and benzene concentrations observed were from a basement carpark and were 24.7 parts per billion (ppb) and 5.6 ppb, respectively. The maximum xylenes concentration was 29.4 ppb and occurred in a nightclub where styrene was also detected. A factor analysis of the data was undertaken. Two key factors emerge that appear to be associated with petroleum and motor vehicles and environmental tobacco smoke. A third significant occurrence was a high concentration of chloroform that was observed at a sports centre complex with a swimming pool text and was uncorrelated with other compounds in the data set. This study indicates that locations associated with motor vehicles and petrol fuel, tobacco and wood smoke and chlorinated water represent the major risks for personal exposure to VOCs in Perth.  相似文献   

19.
依据介质阻挡放电(DBD)和溶液吸收处理气态污染物的原理,设计出一种DBD和水吸收联合降解挥发性有机化合物(VOCs)的实验装置.研究其对甲苯的降解效果.考察了放电电压、甲苯初始浓度、模拟废气流量对甲苯降解效果的影响.分析了DBD和水吸收的相互作用.结果表明.DBD和水吸收联合可以提高甲苯的降解率.在放电电压为15.9 kV时甲苯的降解率为81.5%.比单独放电时提高了13.3百分点;甲苯的降解率随着放电电压增大而升高,随着气体流量和甲苯初始浓度增大而降低.该技术可以作为放电等离子体前处理工艺,为高效处理上业废气提供参考.  相似文献   

20.
研究了废弃物基活性炭对挥发性有机污染物中的典型组分--甲苯的吸附特性.结果表明,废弃物基活性炭吸附甲苯等温线的类型系优惠型吸附等温线,表明具有良好的吸附能力;同时其吸附甲苯时穿透时间的对数与甲苯入口浓度的对数之间具有良好的线性相关性,即可由吸附高浓度甲苯时的穿透时间估算低浓度时的穿透时间;动态吸附时废弃物基活性炭的中孔对甲苯亦具有一定的吸附性能.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号